⟦4f5a4d274⟧ TextFile

    Length: 1944 (0x798)
    Types: TextFile
    Names: »MTC_PREFIX.S«

Derivation

└─⟦e0c43619c⟧ Bits:30005797 CR80 Disc pack ( Vol:FNJ1 861029/EC CR80 S/W Package II+III+IV+V+VII )
    └─ ⟦this⟧ »CSP004_V0801.D!CSS126.D!MTC_PREFIX.S« 

TextFile


%LIST     %LIST     %LIST
"-----------------------------------------------------------------------
"
"  MODULE NAME:           SWELL MAGTAPE INTERFACE PREFIX
"  MODULE ID NMB:         CSS/883
"  MODULE VERSION:        02
"  MODULE RELEASE:        04
"  RELEASE DATE:          860606
"
"-----------------------------------------------------------------------
%NOLIST   %NOLIST   %NOLIST


CONST          "EXTRA ERROR CODES
  DEVICE_FAILURE             = TAPE_DEVICE_FAILURE;
  RECOVERABLE_DEVICE_FAILURE = TAPE_SOFT_FAILURE;

  LOGICAL_END_OF_TAPE_SENSED = LOGICAL_EOT_SENSED;
  FILEMARK_SENSED            = FILE_MARK_SENSED;

  "MAGTAPE CONTROLLER ERROR SYMBOLS"

  "TRANSPORT STATUS BITS"

  TCR = 14  "Tape Controller Ready" ;
  ONL = 11  "On Line" ;
  RDY = 10  "ReaDY";
  RWD =  9  "ReWinDing";
  WPT =  8  "Write ProTected";
  BOT =  7  "Beginning Of Tape";
  EOT =  6  "End Of Tape";
  NRZI=  5  ;
  SGL =  3  "SinGLe head";

  "TRANSFER STATUS BITS"

  PFL = 15  "Power Failure";
  ESY = 13  "Error SummarY";
  THE =  8  "Tape Hard Error";
  TCE =  7  "Tape Correctable Error";
  CPE =  6  "Cable Parity Error";
  MPE =  5  "Memory Parity Error";
  ETS =  4  "End of Tape Sensed";
  DTE =  3  "Data Timing Error";

  "STATUS CODES"

  NOR =  0  "NORmal termination";
  IVO =  1  "InValid Operation";
  TOL =  2  "Tape transport is OffLine";
  TNR =  3  "Tape transport is Not Ready";
  TRW =  4  "Tape transport is ReWinding";
  TWP =  5  "Tape is Write Protected";
  IRL =  6  "Invalid data-Record Length";
  MID =  7  "Missing IDentifier at phase encoding(PE)";
  BTS =  8  "Beginning of Tape Sensed";
  FMS =  9  "File Mark Sensed";
  LET = 10  "Logical End of Tape";
  SDR = 11  "Short Data Record";
  LDR = 12  "Long Data Record";
  CBE = 13  "Command Buffer parity Error";
  IRO = 14  "Invalid Read Offset";

TYPE             "FOR SKIP COMMANDS
  SKIPKINDS = (RECS,FILEM,FILEM_RECS,LEOT);
  DIRECTION = (FORWARDS,REVERSE);

"FF«ff» «a5»