top - download
⟦021c44d3a⟧ Wang Wps File
Length: 9917 (0x26bd)
Types: Wang Wps File
Notes: ACCESS FLTD SYS. CONF.
Names: »3453A «
Derivation
└─⟦1f76ea5a7⟧ Bits:30006218 8" Wang WCS floppy, CR 0277A
└─ ⟦this⟧ »3453A «
WangText
:…09…:…86…1
…02…
…02…
…02…
…02…
…02…IJO/830308…02……02…#
ACCESS
FLTD SYSTEM
CONFIGURATION
…02…
…02…ACCESS
T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲
1 SCOPE ........................................
4
2 BASELINE DOCUMENTATION .......................
4
3 DEMONSTRATION AREA LAYOUT ....................
4
4 ACCESS FLTD SYSTEM CONFIGURATION .............
6
PU-CRATE ASSY ................................
8
CU-CRATE ASSY ................................
10
WD-CRATE ASSY ................................
12
ADAPTOR CRATE ASSY ...........................
13
TU #1 ASSY ..................................
14
TU #2 ASSY ..................................
15
5 CONFIGURATION/EQUIPMENT SPECIFICATION ........
16
5.1 BAY A-B-C ................................
16
5.2 RACK D ...................................
20
5.3 RACK E ...................................
21
5.4 PERIPHERAL EQUIPMENT .....................
22
5.5 INTER UNIT CABLE ASSEMBLY ................
22
1̲ ̲ ̲S̲C̲O̲P̲E̲
The scope of this document is to establish a specification
of the equipment forming the
ACCESS FLTD SYSTEM.
2̲ ̲ ̲B̲A̲S̲E̲L̲I̲N̲E̲ ̲D̲O̲C̲U̲M̲E̲N̲T̲A̲T̲I̲O̲N̲
CAMPS Hardware Assembly Breakdown/Hardware Tree
CPS/SDS/017, Issue 3.
3̲ ̲ ̲D̲E̲M̲O̲N̲S̲T̲R̲A̲T̲I̲O̲N̲ ̲A̲R̲E̲A̲ ̲L̲A̲Y̲O̲U̲T̲
Overleaf is shown layout of the Demonstration Area.
The FLTD test will be carried out in this area.
(Fig. 3-1).
TBD.
DEMONSTRATION AREA LAYOUT…01…Fig. 3-1
4̲ ̲ ̲A̲C̲C̲E̲S̲S̲ ̲F̲L̲T̲D̲ ̲S̲Y̲S̲T̲E̲M̲ ̲C̲O̲N̲F̲I̲G̲U̲R̲A̲T̲I̲O̲N̲
Overleaf is shown the system configuration to be used
for Demonstration (Fig. 4-1).
PU-, CU-, and WD Crate Assembly are shown in Fig. 4-2
to 4-6.
Also is shown Adaptor Crate and TDX-crate #1 and #2
Assembly. (Figs. 4-7 to 4-9).
Computer racks (A, B, C) are part of CAMPS Site 15,
and will be slightly modified for this application,
that is the CU-Crate will have one DISC.CTRL and the
FD.CTRL removed and a PARR.CTRL and a TAPE CTRL mounted.
The IMD will be mounted in rack A substituting the
10 U Blank Panel.
The Tape Station will be mounted in rack D, and the
two CTX-crates in rack E.
The Computer racks will be moved fully assembled to
the Demonstration Area shortly after FAT Site 15 has
been completed.
Rack D and E will be integrated in the Demonstration
Area.
FLTD SYSTEM CONFIGURATION…01…Figure 4.1
PU-CRATE ASSEMBLY (FRONT VIEW)…01…Figure 4.2
PU-CRATE ASSEMBLY (REAR VIEW)
Figure 4.3
CU-CRATE ASSEMBLY (FRONT VIEW)…01…Figure 4.4
CU-CRATE ASSEMBLY (REAR VIEW)…01…Figure 4.5
WD-CRATE ASSEMBLY …01…Figure 4.6
ADAPTOR CRATE ASSEMBLY …01…Figure 4.7
TDX-CRATE ASSEMBLY #1
Figure 4.8
TDX-CRATE ASSEMBLY #2
Figure 4.9
5̲.̲ ̲ ̲C̲O̲N̲F̲I̲G̲U̲R̲A̲T̲I̲O̲N̲/̲E̲Q̲U̲I̲P̲M̲E̲N̲T̲ ̲S̲P̲E̲C̲I̲F̲I̲C̲A̲T̲I̲O̲N̲
For further information on items see CPS/SDS/017
issue 3.
5.1 B̲A̲Y̲ ̲A̲-̲B̲-̲C̲
R̲a̲c̲k̲ ̲A̲ Q̲t̲y̲.̲
Right End Rack
1
Processor Unit
-
Processor Crate
1
Power Supply CR80D
2
MAP I/O DMA
1
STI
1
RAM 512K
2
CPU CACHE
3
Blank Panel 1M Front D 10
MBT
4
TIA
2
MIA
1
CCA
1
M-Fan Assy.
1
Database IDM 500
1
Disk Drive MMD
1
Mains Switch
1
X-Net Terminal Outlet
2
Power Distribution Panel
1
Power Line Filter
1
Blank Panel 1U
1
Blank Panel 2U
1
R̲a̲c̲k̲ ̲B̲ Q̲t̲y̲.̲
Intermediate Rack
1
Channel Unit
-
Channel Crate
1
Power Supply CR80D
2
Disk Controller
2
Parr. Controller
1
Tape Controller
1
LTU
2
Blank Panel 1M Front D
6
MBT
2
CCA
1
LIA-N
2
PCA
1
TCA
1
DCA
2
CIA-A
1
CIA-B
1
CUCP
1
M-Fan Assy.
1
Watchdog Unit
-
Watchdog Crate
1
LTU
1
Blank Panel 1M Front D
6
WCA
1
CCBA Panel
1
Blank Panel 8M Front
1
Floppy Disk (2 units) (not used)
1
Disk Drive SMD
1
Mains Switch
1
Power Distribution Panel
1
Power Line Filter
1
Blank Panel 1U
3
R̲a̲c̲k̲ ̲C̲ Q̲t̲y̲.̲
Left End Rack
1
Processor Unit
-
Processor Crate
1
Power Supply CR80D
2
MAP I/O DMA
1
STI
1
RAM 512K
2
CPU CACHE
3
Blank Panel 1M Front M 10
MBT
4
TIA
2
MIA
1
CCA
1
M-Fan Assy.
1
Adaptor Unit
-
Opto T/R
2
V24/V28 (L/L) Adaptor 1 Channel
4
Blank Panel 1M Front
7
Blank Panel 2M Front
5
Blank Panel 1M Rear
1
Adaptor Power Supply
2
Back Panel 8
2
Adaptor Crate
1
Cable Channel Assy.
1
S-Fan Assy.
1
Disk Drive MMD
1
Mains Switch
1
X-Net Terminal Outlet
2
Power Distribution Panel
2
Blank Panel 1U
2
Blank Panel 2U
1
Ground Wire for BP-8
2
CCB Panel
1
C̲a̲b̲i̲n̲e̲t̲ ̲A̲s̲s̲e̲m̲b̲l̲y̲ ̲(̲R̲a̲c̲k̲ ̲A̲-̲B̲-̲C̲)̲ Q̲t̲y̲.̲
Rack A Assy.
1
Rack B Assy.
1
Rack C Assy.
1
Identification Plate
3
Ground Wire P/N 5.05419-01
6
Ground Wire P/N 5.05419-02
6
Ground Wire P/N 5.05419-03
3
Supporting Slide Left 13
Supporting Slide Right 13
Stretching Slide MMD Left
2
Stretching Slide MMD Right
2
Panel Mounting Rail Type 1
9
Panel Mounting Rail Type 2
9
Cable Channel
7
Mounting Rail 390x142x20
3
Mounting Rail 390x40x20 11
Stretching Slide SMD Left
1
Stretching Slide SMD Right
1
Supporting Slide for Fan Left
1
Supporting Slide for Fan Right
1
Cable Tie Assy.
1
I̲n̲t̲e̲r̲ ̲R̲a̲c̲k̲ ̲C̲a̲b̲l̲e̲ ̲A̲s̲s̲e̲m̲b̲l̲y̲ ̲(̲R̲a̲c̲k̲ ̲A̲-̲B̲-̲C̲)̲
Data Channel Cable P/N 5.05415-00
2
CCB Cable P/N 5.05413-00
1
Disk Drive Cable A
3
Disk Drive Cable B
3
WDCC Cable P/N 5.05412-00
2
X-Net Bus Cable P/N 5.05402-00
4
V24 Cable P/N 5.05445-00
2
V24 Cable P/N 5.05422-01
4
80D Power Cable 1m P/N 5.05410-01
4
80S Power Cable 2.5m P/N 5.05409-02
2
80S Power Cable 3.5m P/N 5.05409-03
3
R̲a̲c̲k̲ ̲A̲ ̲I̲n̲t̲e̲r̲n̲a̲l̲ ̲C̲a̲b̲l̲e̲ ̲A̲s̲s̲e̲m̲b̲l̲y̲
TIA to X-Net Outlet Cable P/N 5.05417-00
2
80D Power Cable 0.5m P/N 5.05410-00
4
80S Power Cable 2.5m P/N 5.05444-02
1
80D Power Cable 1.5m P/N 5.05317-00
1
Term Resistor P/N 6.44720-20
4
R̲a̲c̲k̲ ̲B̲ ̲I̲n̲t̲e̲r̲n̲a̲l̲ ̲C̲a̲b̲l̲e̲ ̲A̲s̲s̲e̲m̲b̲l̲y̲ Q̲t̲y̲.̲
Disk Drive Cable A
1
Disk Drive Cable B
1
80D Power Cable 1.5m P/N 5.05317-00
2
80S Power Cable 0.5m P/N 5.05409-00
1
80S Power Cable 2.5m P/N 5.05444-02
1
Term Resistor P/N 5.04258-00
2
R̲a̲c̲k̲ ̲C̲ ̲I̲n̲t̲e̲r̲n̲a̲l̲ ̲C̲a̲b̲l̲e̲ ̲A̲s̲s̲e̲m̲b̲l̲y̲
TIA to X-Net Outlet Cable P/N 5.05417-00
2
80D Power Cable 0.5m P/N 5.05410-00
4
80D Power Cable 1m P/N 505410-01
2
80D Power Cable 1.5m P/N 5.05317-00
1
80S Power Cable 0.5m P/N 5.05409-00
1
5.2 R̲A̲C̲K̲ ̲D̲
STAND ALONE TRANSRACK 1
TAPE STATION PERTEC 9000 1
5.3 Q̲t̲y̲.̲
Rack E: Transrack
1
Cable Channel Assy
2
TDX Unit (#1)
-
CTX Crate
1
TDX Controller
1
BSM-X
1
LTUX-S
2
Opto T/R
8
Power Supply CR80S
1
Adaptor Power Supply
1
BSM-X Panel
1
Blank Panel 1M Front S
3
Blank Panel 2M Front S
2
Blank Panel 4M Rear S
3
BSM-X to TDX Contr. cable
1
TDX Unit (#2)
-
CTX Crate
1
TDX Controller
1
BSM-X
1
LTUX-S
2
Opto T/R
4
Power Supply CR80S
1
Adaptor Power Supply
1
BSM-X Panel
1
Blank Panel 1M Front S
7
Blank Panel 2M Front S
2
Blank Panel 4M Rear
3
BSM-X to TDX Contr. Cable
1
S-Fan Assy
1
Mains Switch
1
X-Net Terminal Outlet
6
CCB Panel
1
Power Distribution Panel
1
Blank Panel 3U
2
Blank Panel 5U
2
Blank Panel 1U
2
R̲a̲c̲k̲ ̲E̲ ̲I̲n̲t̲e̲r̲n̲a̲l̲ ̲C̲a̲b̲l̲e̲ ̲A̲s̲s̲e̲m̲b̲l̲y̲
TDX-Ctrl. to X-Net Outlet P/N 5.05418-00
2
BSM-X to X-Net Outlet P/N 5.05416-00
4
80S Power Cable 0.5m P/N 5.05409-00
2
80S Power Cable 1m P/N 5.05409-01
2
X-Net Bus Cable P/N 5.05402-00
5.4 P̲E̲R̲I̲P̲H̲E̲R̲A̲L̲ ̲E̲Q̲U̲I̲P̲M̲E̲N̲T̲
VDU Delta 7260 TC
5
MSP Tracor 8000
5
LINE PRINTER DATA PRODUCTS 8600
1
5.5 I̲N̲T̲E̲R̲ ̲U̲N̲I̲T̲ ̲C̲A̲B̲L̲E̲ ̲A̲S̲S̲E̲M̲B̲L̲Y̲ Q̲t̲y̲.̲
Opto Cables (Length TBD) 10
Signal Cable to Line Printer
1
X-Net Bus Cable Between Rack E and C (Length TBD)
4
CCB Cable Between Rack E and C (Length TBD)
1