…02…BHB/830511…02……02…#
MINUTES OF MEETING NO. 33
…02……02…CAMPS










            SHAPE/CR
…02……02……02……02…          …02……0f……0f…83-05-11…02… 33. …02…CR A/S…0e……0e…

          …0f……0f…Minutes of Meeting FAT sites 8 + 14 Between
          SHAPE and…0e……0e…
         …0f……0f…CHRISTIAN ROVSING A/S 11th May 1983…0e……0e…


…0f……0f…SHAPE…0e……0e…
         
Mr. E. Bentley              K. Nybroe-Nielsen    Jan
                                                 Holm
                       Bjarne Berthold           Gert
                                                 Jensen
HMAK:                  Erik Villadsen (QA)
Mr. T. [strup               Ib Johansen
                       Carsten Villadsen
                            




Ref a)   CPS/TPR/037 FAT Spec + Procedure for Site
         8
    b)   CPS/TPR/036 FAT Spec + Procedure for Site
         14
           c)   CPS/AUX/061 FAT Spec + Procedure for
                Resync Module


1.       The FAT of the subject site was conducted
         using ref a) for site 8 and ref b) for site
         14. Ref c) was used to test the resync module.
         The FAT for both sites was  completed.


2.       FAT Site 8 had the following discrepancies
         or defects.

                Discrepancies:
                --------------

                a)  LTX-s marked with wrong part No.

                    Action: Corrected

                b)  4 channel adapter, S/N 107, failed

                    Action: CR to report reason for
                    failure with test report submittal.

                c)  Intermittant boot error

                    Action: CR to report cause and
                    solution to probl