WangText




…02…           

…02…SRA/820203…02……02…#
INTERN MEDDELELSE NO. 275
…02……02…CAMPS








         To:     LSN, GB, ASM, GJ, FE, URH, OE, FC
         From:   BHB/SRA

         S̲u̲b̲j̲e̲c̲t̲:̲ ̲A̲m̲b̲i̲e̲n̲t̲ ̲t̲e̲m̲p̲e̲r̲a̲t̲u̲r̲e̲ ̲c̲o̲n̲d̲i̲t̲i̲o̲n̲s̲ ̲f̲o̲r̲ ̲C̲A̲M̲P̲S̲

         1.  C̲A̲M̲P̲S̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲S̲.̲

             Ambient temperature: 10…0e…o…0f…C. - 40…0e…o…0f…C.
             Rate of change     : max. 10…0e…o…0f…C./hour.
             Altitude           : 0 - 2000m.

         2.  S̲U̲G̲G̲E̲S̲T̲E̲D̲ ̲I̲N̲T̲E̲R̲N̲A̲L̲ ̲C̲R̲ ̲S̲T̲A̲N̲D̲A̲R̲D̲.̲

             a)  All modules are functionally tested at 65…0e…o…0f…C.

             b)  Module MTBF is calculated at T…0f…amb…0e…= 43…0e…o…0f…C.

             c)  At sealevel (0m) the maximum average temperature
                 increase (T…0f…av-inc(0)…0e…) and the maximum peak
                 temperature increase (T…0f…i-inc(0)…0e…) above a crate
                 with forced cooling shall be (refer to the
                 figure below):

                 T…0f…av-inc(0)…0e… = (T1+T2+T3+T4)/4 - T…0f…amb…0e… =

                 15…0e…o…0f…C.

                 T…0f…i-inc(0)…0e… = 20…0e…o…0f…C. (i = 1, 2, 3, 4).


                      Top of D crate
                 T1     T2     T3     T4
                  ̲x̲ ̲ ̲ ̲ ̲ ̲ ̲x̲ ̲ ̲ ̲ ̲ ̲ ̲x̲ ̲ ̲ ̲ ̲ ̲ ̲x̲ ̲





         Rear of                                Front of
         D crate                                D crate
                          Forced
                         Cooling



                  ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

                    Bottom of D crate


         3. C̲A̲M̲P̲S̲ ̲O̲P̲E̲R̲A̲T̲I̲N̲G̲ ̲C̲O̲N̲D̲I̲T̲I̲O̲N̲S̲.̲

             a)  Based upon 2c the max average temperature increase
                 and max peak temperature increase at 2000 m
                 altitude are calculated as:

                 Air pressure at sealevel (0m) is normally 760
                 mm Hg, and at 2000m 600 mm Hg. Thus the forced
                 cooling airflow at 2000m (airflow…0f…(2000)…0e…) is
                 reduced compared to the airflow at sealevel
                 (airflow…0f…(0)…0e…).

                 airflow…0f…(2000)…0e… = airflow…0f…(0)…0e… * 600/760

                 This causes a rise in both T…0f…av-inc…0e… and T…0f…i-inc…0e….

         T…0f…av-inc(2000)…0e…= T…0f…av-inc(0)…0e…*760/600 = 15*760/600 =

         19…0e…o…0f…C.
         …0e…-----…0f…
         T…0f…i-inc(2000)…0e…= T…0f…i-inc(0)…0e…*760/600 = 20*760/600 =

         25.3…0e…o…0f…C. (i = 1, 2, 3, 4).
         …0e…-------…0f…
             b)  Combining 2a and 3a it is seen that CAMPS will
                 function at T…0f…amb…0e… = 40…0e…o…0f…C.

             c)  Combining 2b and 3a it is seen that:

                 1) operation with T…0f…amb…0e… = 10…0e…o…0f…C. - 18…0e…o…0f…C. is provide
                 with no degraded reliability.

                 2) operation with T…0f…amb…0e… = 18…0e…o…0f…C. - 40…0e…o…0f…C. is only
                 provide with degraded reliability.

         4. T̲H̲E̲R̲M̲A̲L̲ ̲D̲E̲S̲I̲G̲N̲.̲

             CAMPS H/W strongly recommends that the overall
             thermal design is improved to provide operation
             with T…0f…amb…0e… = 10…0e…o…0f…C. - 28…0e…o…0f…C. and no degraded reliability.