DataMuseum.dk

Presents historical artifacts from the history of:

CR80 Wang WCS documentation floppies

This is an automatic "excavation" of a thematic subset of
artifacts from Datamuseum.dk's BitArchive.

See our Wiki for more about CR80 Wang WCS documentation floppies

Excavated with: AutoArchaeologist - Free & Open Source Software.


top - download

⟦10e953b77⟧ Wang Wps File

    Length: 8775 (0x2247)
    Types: Wang Wps File
    Notes: Preliminary Equipm.Data   
    Names: »1125A «

Derivation

└─⟦af7ebed0d⟧ Bits:30006042 8" Wang WCS floppy, CR 0067A
    └─ ⟦this⟧ »1125A « 

WangText




…02…CPS/TCN/025

…02…KM//810915…02……02…#
Preliminary Equipment Data for CAMPS
Remote Terminals…02…KM/810708…02…CAMPS









                     T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲




   1  INTRODUCTION ..................................
      4

   2  GENERAL DESCRIPTION ...........................
      4
     2.1  SYSTEM CONCEPT ............................
        4
     2.2  SITE PREPARATION AND INSTALLATION PLANNING 
        8

   3  SITE PREPARATION AND INSTALLATION
      REQUIREMENTS ..................................
      8
     3.1  EQUIPMENT AT MAIN SITES ...................
        8
     3.2  EQUIPMENT AT REMOTE LOCATIONS .............
        9

   4  EQUIPMENT CHARACTERISTICS .....................
     11
     4.1  MAIN SITES ................................
       11
     4.2  REMOTE SITES ..............................
       14


                     1̲ ̲ ̲I̲N̲T̲R̲O̲D̲U̲C̲T̲I̲O̲N̲



         This document contains preliminary equipment data and
         requirements, which should support Host Nation's preliminary
         site design of CAMPS Remote Terminal installations.









                  2̲ ̲ ̲G̲E̲N̲E̲R̲A̲L̲ ̲D̲E̲S̲C̲R̲I̲P̲T̲I̲O̲N̲



2.1      S̲Y̲S̲T̲E̲M̲ ̲C̲O̲N̲C̲E̲P̲T̲

         The CAMPS Remote Terminal (CRT) concept provides a
         V24 connection between the main CAMPS site and a remote
         site.  Of the 8 channel connections available at each
         remote site, 4 are used to support 2 VDUs and 2 MSPs,
         one is used for an OCR connection and 3 are auxiliary
         channels.

         The equipment associated with the CRT is depicted in
         figure 2.1.  Eight channels of the main site are transmitted
         over a single communications line by using statistical
         multiplexers (Stat.mux) at each end of the crypto/modem
         lines.

         At the main sites, the CRT line connections are made
         in the CRT Line termination racks which contain the
         LTUXs, crates etc. (see figure 2.1, sheet 2).

         At the remote sites, connections to the terminals are
         made by opto-links while connections to the auxiliary
         channels and the OCR are V28(L) links.  (See figure
         2.1, sheet 3).

















































                Figure 2.1 (Sheet 1 of 3)
              Typical CRT Line Configuration

















































                Figure 2.1 (Sheet 2 of 3)
         TYPICAL CRT CONFIGURATION AT MAIN SITES

















































                FIGURE 2.1 (SHEET 3 of 3)
         TYPICAL CRT CONFIGURATION OF REMOTE SITE


2.2      S̲I̲T̲E̲ ̲P̲R̲E̲P̲A̲R̲A̲T̲I̲O̲N̲ ̲A̲N̲D̲ ̲I̲N̲S̲T̲A̲L̲L̲A̲T̲I̲O̲N̲ ̲P̲L̲A̲N̲N̲I̲N̲G̲

         a)  The CRT equipment for both the main and remote
             locations will be installed by CR at the same time
             they install the main CAMPS equipment.  (please
             refer to the main site installation schedule).

         b)  Civil works requirements (space, power etc.) necessary
             to prepare both the main and remote site will be
             incorporated in a single civil works requirement
             (CWR) package for the corresponding main-site.
              The As-To-Be-Built and As-Built documentation
             for the affected main site will be expanded by
             CR to incorporate the CRT equipment at main and
             remote locations.









    3̲ ̲ ̲S̲I̲T̲E̲ ̲P̲R̲E̲P̲A̲R̲A̲T̲I̲O̲N̲ ̲A̲N̲D̲ ̲I̲N̲S̲T̲A̲L̲L̲A̲T̲I̲O̲N̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲S̲



3.1      E̲Q̲U̲I̲P̲M̲E̲N̲T̲ ̲A̲T̲ ̲M̲A̲I̲N̲ ̲S̲I̲T̲E̲S̲

         a)  At each main site CR will provide and install a
             CRT-rack (at Proto 2 CRT-racks are required) in
             the Camps room.  (refer to fig. 2.1)
             The rack(s) will be bolted to the 3-bay line termination
             rack assembly (D,E,F).-  The rack(s) will be designated
             as rack G,(H).

         b)  SHAPE will provide and install:

             1)  One 19 inch rack containing a red patch jack
                 field (RPJF), a B-1000 crypto, and a B-1000/14
                 isolator panel.

             2)  One 19 inch rack containing a black patch jack
                 field (BPJF) and a MODEM.



         c)  The signal cable and connections from the filter
             box (IDF) of rack F to the RPJF, from the RPJF
             to the Crypto/isolator, from the Crypto/isolator
             to the BPJF, from the BPJF to the MODEM and from
             the MODEM to the Main Distribution Frame (MDF)
             will be provided and installed by SHAPE/Territorial
             Host Nation (see figure 2.1).

             Rack G(H) requires a secure ground and pink power
             from the CAMPS power distribution board.  SHAPE/Territorial
             Host Nation will provide this power and ground
             in accordance with the CWR for each site.



3.2      E̲Q̲U̲I̲P̲M̲E̲N̲T̲ ̲A̲T̲ ̲R̲E̲M̲O̲T̲E̲ ̲L̲O̲C̲A̲T̲I̲O̲N̲S̲

         a)  At remote locations (PHQ) CR will provide and install
             a CRT-rack and the contractually specified number
             of user terminals.  (TYPICALLY 2 VDUs and 2 MSPs).
              This equipment will be installed in rooms designated
             by SHAPE/Local Commands.

         b)  The signal cable and connections from filter box
             (IDF) of the CRT-rack to the RPJF, from the RPJF
             to the crypto/isolator panel, from the crypto/isolator
             panel to the BPJF, from the BPJF to the MODEM and
             from the MODEM to the MDF will be provided and
             installed by SHAPE/Territorial Host Nation.

         c)  The OCR connection and the three auxiliary V28(L)
             connections to the filter box of the CRT-rack will
             be provided and installed by SHAPE/Host Nation.

         d)  OPTO-cable and connections to user terminals (VDU's
             and MSP's) will be provided and connected to the
             CRT-rack and the terminals by CR.
             SHAPE/Territorial Host Nation will run the opto-cables
             between the CRT-rack and the terminals in conduits
             or ducts provided and installed by SHAPE/Territorial
             Host Nation.



         f)  The CRT-rack requires a secure ground and pink
             power. SHAPE/Territorial Host Nation will provide
             this power and ground in accordance with the CWR.

             The user terminals will be supplied with power
             (pink or black) and ground (secure or safety) from
             SHAPE/Territorial Host Nation provided 3-pin outlets
             in accordance with the CWR.





               4̲ ̲ ̲E̲Q̲U̲I̲P̲M̲E̲N̲T̲ ̲C̲H̲A̲R̲A̲C̲T̲E̲R̲I̲S̲T̲I̲C̲S̲



4.1      M̲A̲I̲N̲ ̲S̲I̲T̲E̲S̲:̲

         a)  The CRT-rack installed at each main site is an
             EMI-rack bolted to rack F.  (refer to figure 4.1).
             The CRT-rack is rack G.

         b)  Power to rack G is supplied via the PLF in rack
             E.  The power consumption of rack G is 1000 W maximum.

         c)  The physical data is given in table 4.1.
             Mechanically the CRT-rack is identical to the other
             main site racks.

         d)  The CRT signal cables enter through the IDF in
             rack F (refer to figure 4.1).

















































                        FIGURE 4.1
             RACKS AND CABLING AT MAIN SITES.







             SIZE              WEIGHT    Power Consumption
             (W x D x H) (cm)  (kg)      (WATT)

  Rack G     63 x 120 x 180    450       1000
  Rack H     63 x 120 x 180    450       1000





































                     Table 4.1
           Equipment size, weight, power


4.2      R̲E̲M̲O̲T̲E̲ ̲S̲I̲T̲E̲S̲

         a)  The CRT-rack installed at each remote site is an
             EMI-rack with top mounted power and signal cable
             entrances only as shown on figure 4.2.

         b)  Power requirements and connections for the CRT-rack
             and terminals are shown in figure 4.3.  Power consumption
             of the CRT-rack is 500 W maximum.

         c)  Physical data for the CRT-rack and terminals is
             given in table 4.2.

         d)  Typical planning data for sites concerning user
             terminals is given in figure 4.4 and figure 4.5.

















































                 Figure 4.2  Remote Site
                    Typical CRT-Rack.







              SIZE             WEIGHT    Power Consumption
              (W x D x H)(cm)  (kg)      (WATT)

  CRT Rack    63 x 120 x 180   450       500
  VDU         48 x 79 x 43      25       250
  MSP         64 x 74 x 28      57       350




































                     Table 4.2
           Equipment size, weight, power

















































                        Figure 4.3
                 TYPICAL CRT-INSTALLATION














































                         Fig. 4.4
                     …01…User Terminals
Power and Grounding Requirements opto Signal Cable Termination

















































                         Fig. 4.5

                      User Terminals
         Typical Layouts and Access Requirements.