A  P  P  E  N  D  I  X    B…01…---------------------------------…01……01…TECHNICAL REQUIREMENTS…01…AND…01…SPECIFICATIONS
 FOR FILTERED CONNECTORS






         T̲E̲C̲H̲N̲I̲C̲A̲L̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲S̲ ̲A̲N̲D̲ ̲S̲P̲E̲C̲I̲F̲I̲C̲A̲T̲I̲O̲N̲S̲

         The filtered connectors to be supplied under this contract
         shall meet the specifications and requirements specified
         in this appendix.


1        G̲E̲N̲E̲R̲A̲L̲ ̲S̲P̲E̲C̲I̲F̲I̲C̲A̲T̲I̲O̲N̲

         2 version of filtered connectors shall be delivered.
         General specifications: see figure B1.

1.1      10-PIN VERSION, PART NUMBER: 52-762-003

1.2      18-PIN VERSION, PART NUMBER: 52-762-004


2        P̲I̲N̲ ̲A̲L̲L̲O̲C̲A̲T̲I̲O̲N̲

2.1      10-PIN VERSION

         The following pins shall be connected:

         1, 2, 3, 5, 6, 7, 14, 16, 19, 20

         Pin 1 is connected to chassis in both ends. All other
         pins are connected through filters (see figure B1).

2.2      1̲8̲-̲P̲I̲N̲ ̲V̲E̲R̲S̲I̲O̲N̲

         The following pins shall be connected:

         1, 2, 3, 4, 5, 6, 7, 8, 12, 14, 15, 16, 17, 18, 19,
         20, 24, 25.

         Pin 1 is connected to chassis in both ends. All other
         pins are connected through filters (See figure B1)


3        M̲E̲C̲H̲A̲N̲I̲C̲A̲L̲ ̲D̲I̲M̲E̲N̲S̲I̲O̲N̲S̲

         See figure B1.

4        E̲L̲E̲C̲T̲R̲I̲C̲A̲L̲ ̲C̲H̲A̲R̲A̲C̲T̲E̲R̲I̲S̲T̲I̲C̲S̲

         See figure B1.

5        E̲N̲V̲I̲R̲O̲N̲M̲E̲N̲T̲A̲L̲ ̲C̲O̲N̲D̲I̲T̲I̲O̲N̲S̲

         In designing the equipment to meet the specified requirements
         no account need be taken of catastrophic events such
         as fire, flood, explosion, etc., which are beyond the
         control of an equipment manufacturer.



         The equipment will normally operate within accomodation
         suitable for the operation of similar equipment produced
         for commercial use.

         After initial adjustments have been made, the equipment
         shall maintain normal operation under all specified
         environmental and power supply conditions.

         a)  Temperature and humidity

             The equipment shall continue to function when the
             humidity and temperature of its environment are
             within the ranges and cycling specified below.

             The equipment shall continue to operate in a fully
             satisfactory manner even under the worst conditions
             specified below.

             a1) Temperature

                 Range:  10 to 50 deg. C
                 Change: Mac. 10 deg. C per hour

             a2) Humidity (relative humidity = RH)

                 Range:  40 to 90 per cent RH, non-condensing
                 Change: Max. 6 per cent RH per hour, non condensing

             a3) Altitude

                 Range:  Sea level to 2000 meters

                 The equipment shall be designed in such a way
                 that the loss of site air conditioning or heating
                 will not cause a catastrophic failure within
                 15 minutes after the loss.

         b)  Dust, fumes

             The equipment shall be able to operate continously
             and with normal scheduled preventive maintenance
             in the following air environment.

             b1) Air cleaness

                 PARTICLE SIZE           MAX ALLOWABLE NUMBER
                 (̲M̲I̲C̲R̲O̲N̲S̲)̲ ̲ ̲ ̲ ̲           (̲P̲A̲R̲T̲I̲C̲L̲E̲S̲/̲C̲U̲B̲I̲C̲M̲E̲T̲E̲R̲

                 Greater than 5          4 x (10 5)
                 Greater than 1.5        4 x (10 6)
                 Greater than 1          4 x (10 7)



             b2) Fumes

                 Sulphur dioxide max. 14 ppm.


6        T̲R̲A̲N̲S̲M̲I̲T̲T̲E̲D̲ ̲S̲I̲G̲N̲A̲L̲S̲

         The filtered connector will be used for transmission
         of signals with the following main characteristics.

6.1      Standard CCITT V28 (RS 232 C) - Interface

6.2      Transmisison speed up to 10 KHz

6.3      Open Voltage is normally max. 12 Volts between lines
         (pins) with load connected. With disconnected load
         max. 50 volts between lines (pins).























































                        FIGURE B1



























A  P  P  E  N  D  I X   D…01…-----------------------------…01……01…TEST PROCEDURES


         T̲E̲S̲T̲ ̲P̲R̲O̲C̲E̲D̲U̲R̲E̲S̲

D1       SC shall submit to CR for their review and approval
         the test procedures to be used during the First Article
         Test at least 30 days prior to the First Article Test.

         The first article test shall verify that the filtered
         connectors meet the requirements of this contract.

D2       CR shall have the right to be present during the First
         Article Test.

D3       SC shall deliver to CR the First Article Test Report
         immediately after the test.

D4       SC shall deliver to CR the test procedure to be used
         for the Factory acceptance test and a description of