CAMPS SYSTEM DESIGN SPECIFICATION
…02……02…CAMPS









                 T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲



   4  SYSTEM OVERVIEW ..........................   2
     4.1  CONFIGURATION SUMMARY ................   2
       4.1.1  Hardware System Partitioning .....   2
         4.1.1.1 Configuration Elements ........   5
         4.1.1.1.1  Distribution Equipment .....   5
         4.1.1.1.2  TDX Systems ................   7
         4.1.1.1.3  LTUs .......................   9
         4.1.1.1.4  Processor Units ............  11
         4.1.1.1.5  Mass Storage Disks .........  13
         4.1.1.1.6  Watchdog ...................  15

       4.1.1.2  Site Equipment Layout ..........  17
         4.1.1.2.1  Principle Diagram ..........  17
         4.1.1.2.2  Equipment Matrix ...........  23

       4.1.1.3  Site Equipment Complement ......  23
         4.1.1.3.1  Main Rack Design ...........  27
         4.1.1.3.2  Connectivity ...............  30
           4.1.1.3.2.1  VDUs and Medium Speed 
                   Printers Assigned for Users,
                   Paper Tape Reader/Puncher 
                   and OCR .....................  30
           4.1.1.3.2.2  External Circuits: CCIS, 
                   SCARS, TARE. Terminals: VDU 
                   and Printer for S/W Development
                   in the CSSI Site ............  50
           4.1.1.3.2.3  Standard Connected 
                   Peripherals .................  70

       4.1.2 Software Configuration ............  88
         4.1.2.1 Software Subsystems ...........  88
         4.1.2.2 Software Packages .............  88
         4.1.2.3 System Software Subsystem .....  90
         4.1.2.4 Applications Software Subsystem  93
         4.1.2.5 Support Software Subsystem ....  96

       4.1.3 Mapping of Software onto Hardware .  97


                    4̲ ̲ ̲S̲Y̲S̲T̲E̲M̲ ̲O̲V̲E̲R̲V̲I̲E̲W̲



4.1      C̲O̲N̲F̲I̲G̲U̲R̲A̲T̲I̲O̲N̲ ̲S̲U̲M̲M̲A̲R̲Y̲



4.1.1    H̲a̲r̲d̲w̲a̲r̲e̲ ̲S̲y̲s̲t̲e̲m̲ ̲P̲a̲r̲t̲i̲t̲i̲o̲n̲i̲n̲g̲

         The hardware configuration for CAMPS is an integral
         part of a total system concept which also includes
         software and operational procedures.  The system functions
         are allocated between hardware, software, and firmware
         and partitioned so as to provide the optimum implementation
         of the CAMPS systems.

         The allocation of functions between system elements
         has resulted in the hardware configuration described
         in this section.  This configuration has been further
         partitioned into well-defined sub-systems or sub-assemblies.

         Fig. 4.1.1-1 shows the CAMPS Hardware Configuration
         for the Main Site equipment.  The major elements of
         the configuration are:

         a)  Distribution equipment
         b)  TDX-systems
         c)  LTUs (Channel Unit)
         d)  Processor Units
         e)  Disk Systems (Channel Unit)
         f)  Watchdog Processor



















































           Fig. 4.1.1-1…01…C̲A̲M̲P̲S̲ ̲H̲/̲W̲ ̲C̲o̲n̲f̲i̲g̲u̲r̲a̲t̲i̲o̲n̲



         a)  T̲h̲e̲ ̲D̲i̲s̲t̲r̲i̲b̲u̲t̲i̲o̲n̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲ consists of different
             types of equipment used for transfer of the individual
             data exchange channels from the main site to the
             location of each connected terminal/external circuit.

             The different types are based on different transmission
             media, transmission concepts, and the interface
             in the main site equipment.

         b)  T̲h̲e̲ ̲T̲e̲l̲e̲c̲o̲m̲m̲u̲n̲i̲c̲a̲t̲i̲o̲n̲ ̲D̲a̲t̲a̲ ̲E̲x̲c̲h̲a̲n̲g̲e̲ (TDX) system
             performs the interconnection of part of the data
             exchange channels with the Processor Units.

             The LTUXs (Line Termination Unit, TDX) are placed
             in TDX-crates. Each TDX-crate contains LTUXs interfacing
             max. 8 channels.  The two TDX Buses run a multiplexing
             scheme for interconnection of the LTUX Crates with
             either of the 2 Processor Units.

             An LTUX Crate is switched to one of the two redundant
             TDX Buses.

         c)  T̲h̲e̲ ̲L̲T̲U̲s̲ ̲(̲L̲i̲n̲e̲ ̲T̲e̲r̲m̲i̲n̲a̲t̲i̲o̲n̲ ̲U̲n̲i̲t̲s̲)̲ ̲o̲f̲ ̲t̲h̲e̲ ̲C̲h̲a̲n̲n̲e̲l̲
             ̲U̲n̲i̲t̲ interconnect part of the data exchange channels
             with the Processor Units.

             Each LTU interfaces max. 4 data exchange channels.
              An LTU is switched to one of the two redundant
             data channels.  Each data channel is connected
             to a Processor Unit.

         d)  T̲h̲e̲ ̲P̲r̲o̲c̲e̲s̲s̲o̲r̲ ̲S̲y̲s̲t̲e̲m̲ is composed of a dual set
             of processor units, capable of independent operation.

             Each Processor Unit contains multiple CPUs, main
             memory modules and bus interfaces.

         e)  T̲h̲e̲ ̲M̲a̲s̲s̲ ̲S̲t̲o̲r̲a̲g̲e̲ ̲D̲i̲s̲k̲s̲ are shared by the two processor
             units.  Each of the 3 disks is individually switched
             to one of the two data channels.

         f)  T̲h̲e̲ ̲W̲a̲t̲c̲h̲d̲o̲g̲ ̲S̲y̲s̲t̲e̲m̲ coordinates the configuration
             control of the main site equipment.

             Status polling and switching control are performed
             via the Configuration Control Bus (CCB).


             Data are transmitted by the two data channels connected
             to the Processor Units.

             The console terminals of the engineering positions
             are connected to the Watchdog Processor.



4.1.1.1  C̲o̲n̲f̲i̲g̲u̲r̲a̲t̲i̲o̲n̲ ̲E̲l̲e̲m̲e̲n̲t̲s̲

         This section gives a more detailed specification of
         the six configuration elements as defined in sect.
         4.1.1.



4.1.1.1.1    D̲i̲s̲t̲r̲i̲b̲u̲t̲i̲o̲n̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲

         The data channels connecting the CAMPS Main Equipment
         with the individual terminals/external circuits are
         named Data Exchange Channels.

         The individual channels are transmitted to a terminal
         or an external circuit using distribution equipment
         determined by the channel application.  The distribution
         equipment is providing the adaption necessary for the
         transmission of each data channel.

         The distribution systems can be categorized into 5
         categories.

         The characteristics and the applications of each category
         are shown on fig. 4.1.1-2.

         Each channel is connected in the Main site at the Standard
         CCITT V24/V28 interface of the LTUs/LTUXs.

         As indicated on the figure 4.1.1-2 part of the distribution
         equipment is placed in the MAIN SITE racks.




















































           Fig. 4.1.1-2…01…D̲i̲s̲t̲r̲i̲b̲u̲t̲i̲o̲n̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲



4.1.1.1.2    T̲e̲l̲e̲c̲o̲m̲m̲u̲n̲i̲c̲a̲t̲i̲o̲n̲ ̲D̲a̲t̲a̲ ̲E̲x̲c̲h̲a̲n̲g̲e̲ ̲(̲T̲D̲X̲)̲

         The TDX equipment is used for interconnection of individual
         data exchange channels with the Processor Units.

         The interfaces of the data exchange channels in the
         TDX-system are standard CCITT V24/V28 circuits of the
         LTUX modules, see fig. 4.1.1-3.

         Each LTUX module is able to interface 1, 2 or 4 data
         exchange channels dependent on channel specifications,
         and each TDX Crate assembly contains max. 2 LTUX modules.

         Each TDX Crate assembly is switched to one of the two
         TDX Buses.  The switching is controlled by the Watchdog
         Processor through the Configuration Control Bus (CCB).
         The switching is performed by the BSM-X-module and
         the interconnection to the buses are done by a TDX-outlet
         on each bus.

         A TDX Bus links together all the functional elements
         of the TDX System.  The Multiplexing Scheme of the
         TDX Bus is driven and controlled by the TDX controller.
          All the connected data exchange channels of the LTUXs
         are polled and incoming/outgoing data are transferred
         to/from the Processor Units by the TDX Interface Adapters
         (TIAs) and the Supra/TDX Interface Modules (STI) placed
         in the Processor Units.

         The TDX controller of a TDX Bus is placed in one of
         the Connected TDX Crate assemblies.

         The Processor TDX I/F is able to communicate with the
         two TDX Buses through the two TIAs.

         The two TDX Buses are thus fully redundant.



















































                 Fig. 4.1.1-3…01…T̲D̲X̲ ̲S̲y̲s̲t̲e̲m̲



4.1.1.1.3    L̲T̲U̲s̲

         The LTUs are front-end modules used for interconnection
         of individual data exchange channels with the Processor
         Units.

         The interfaces of the data exchange channels in the
         LTUs are as recommended by CCITT in the V24/V28 standards.

         Each LTU module is able to interface 1,2 or 4 data
         exchange channels dependent on channel specifications.

         The position of the LTUs in the CAMPS Main Site Equipment
         is shown on fig. 4.1.1-4.

         An LTU module is positioned in the Channel Unit and
         is connected to the two I/O Buses A and B.  I/O Bus
         A is connected to the Buses of Processor Unit #1 (PU
         #1) by the Data Channel link A.  I/O Bus B is connected
         to PU #2 by the Data Channel link B.

         The LTU is switched to one of the two I/O Buses A or
         B by being claimed through the Bus.  An LTU is thus
         switched to one of the buses at a time.  Each LTU has
         dual Power Input, as power is supplied by the power
         supplies of both I/O-bus A and I/O-bus B.  Normally,
         the load is shared by the two power buses, but one
         power bus is able to supply the total current to the
         modules connected to the bus.

         Adapters, which are part of the Distribution Equipment
         may be placed within the Channel Unit.

         The LTU's buffer blocks data transferred from the PU
         and conducts the transmission on the data exchange
         channels.  Received data blocks are stored in the LTU.
          The PU transfers data from the LTUs governed by the
         interrupt requests delivered from the LTUs.



















































                    Fig. 4.1.1-4…01…L̲T̲U̲s̲



4.1.1.1.4    P̲r̲o̲c̲e̲s̲s̲o̲r̲ ̲U̲n̲i̲t̲s̲

         The CAMPS Main Site equipment contains two identical
         Processor Units (PUs), see fig. 4.1.1-5.  The two PUs
         are placed in redundant elements in the configuration.
          One set of redundant elements is composed of PU #1,
         Data Channel A, the Channel Interface Adapter (CIA-A)
         and I/O Bus A (included the connected Power module).

         The other set of redundant elements is PU#2, Data Channel
         B, CIA-B and I/O-Bus B.

         Each Processor Unit is composed of:

         -   3 Central Processing Units (CPUs) for parallel
             program execution.

         -   2 Random Access Memories (RAMs) forming 256K words
             of working storage.

         -   1 Supra-TDX Bus Interface (STI) interfacing the
             PU to two TDX Bus Interface Adapters (TIAs)

         -   1 Memory Mapping Unit (MAP) which together with
             1 Map Interface Adapter (MIA) performs different
             central functions in the PU, such as:

             1)  Logical to Physical Address translation

             2)  Interfacing the PU to the CU via the Data Channel

             3)  Generating timing signals and servicing of
                 interrupts to the CPUs

             4)  Controlling a V24/V28 communication port to
                 which the Operator Console is connected.

             5)  System Boot Load

         -   2 TDX Bus Interface Adapters (TIAs) interfacing
             the STI to the two TDX Buses.





4.1.1.1.5    M̲a̲s̲s̲ ̲S̲t̲o̲r̲a̲g̲e̲ ̲D̲i̲s̲k̲s̲

         Three disk assemblies are included in the CAMPS Main
         Site equipment.

         Each assembly is composed of a disk drive unit including
         a disk pack, a Disk Controller Adaptor (DCA) and a
         Disk Controller.

         The Disk Controller modules are positioned in the Channel
         Unit (CU) and are connected to the two I/O Buses A
         and B, see fig. 4.1.1-6.

         I/O Bus A is connected to the Buses of Processor Unit
         #1 (PU #1) by the Data Channel link A.  I/O Bus B is
         connected to PU #2 by the Data Channel link B.

         The Disk controller is switched to one of the two I/O
         Buses A/B by being claimed through the Bus.  A Disk
         assembly is thus switched to one of the buses at a
         time.

         The Power Buses of I/O Bus A and B are added together
         on the Disk CTRL module.  Normally, the load is shared
         by the two power buses, but one power bus is able to
         supply the total load of the modules connected to the
         bus.



















































                       Fig. 4.1.1-5

















































                      FIGURE 4.1.1-6


4.1.1.1.6    W̲a̲t̲c̲h̲d̲o̲g̲

         The Watchdog is composed of a Watchdog processor (WDP)
         and a set of control adaptors, see fig. 4.1.1-7.

         The WDP is contained in a self standing Crate Assembly.

         Each control adaptor is placed in the unit/crate under
         control.

         The Control adapter collects the status monitoring
         signals of the Unit/Crate and is able to execute the
         switching functions, which are communicated from the
         WDPU in order to perform configuration control.

         The Control adaptors communicate with the WDPU by Configuration
         Control Bus (CCB).

         In addition to the CCB, two WD control channels are
         used for the exchange of on and off-line diagnostic
         and control information.  The two WD control channels
         connect the WDP with PU #1 and PU #2.

         The VDU and Printer of the CAMPS Main Site Engineering
         position are connected to the WDP.



















































               Fig. 4.1.1-7…01…W̲a̲t̲c̲h̲d̲o̲g̲ ̲S̲y̲s̲t̲e̲m̲



4.1.1.2  S̲i̲t̲e̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲ ̲L̲a̲y̲o̲u̲t̲



4.1.1.2.1    P̲r̲i̲n̲c̲i̲p̲l̲e̲ ̲D̲i̲a̲g̲r̲a̲m̲

         The complete site equipment layout of the CAMPS Main
         Site equipment is shown on fig. 4.1.1.2-1 (drawing
         1-151).

         The functional aspects of the individual configuration
         elements are described in section 4.1.1.1.

         The minor boxes shown on fig. 4.1.1.2-1 represent functional
         modules as well as mechanical modules.  The modules
         are placed in mechanical assemblies named crates or
         crate assemblies.  The crate allocation of each module
         is indicated on fig. 4.1.1.2-1.  The crates are designed
         for mounting in standard 19 inch racks.

         Some configuration elements on fig. 4.1.1.2-1 are not
         placed in crates.  These are selfstanding subsystem
         assemblies and are mounted in the TEMPEST 19 inch racks
         (e.g. disk drives) or are free standing (e.g. terminal
         equipment).

         Two families of modules are used for the CR80 modules,
         the D modules and the S modules.

         The D module concept is presented on fig. 4.1.1.2-2
         and 3.

         The S module concept is presented on fig. 4.1.1.2-4.

         a)  Fig. 4.1.1.2-2 shows the crating of the CR80D Processor
             and Channel Unit.  The three rows of connectors
             visible in the front magazine are accessing the
             upper bus, the lower bus and the external connections.

             Modules on the CAMPS site equipment diagram, fig.
             4.1.1.2-1 in the Processor/Channel Units placed
             between the buses are Front modules, while the
             modules terminating the buses and the modules placed
             below the lower bus are rear modules/adapters.



















































               Fig. 4.1.1.2-1…01…Drawing 1-151
                       (Format A1)


             Rear crate modules/adaptors support the external
             connections of the unit, i.e. signal and power
             cabling.

             Front and rear-crate modules are interconnected
             by flat cables.

         b)  Fig. 4.1.1.2-3 shows the crating of the WD Processor.
              The CR80D minicrate is used.  The concept is as
             described in a) above.  The CR80D minicrate is
             used for smaller configurations.  Power regulation
             and ventilation are integrated in the crate assembly.

         c)  Fig. 4.1.1.2-4 shows the crating of the TDX modules.

             The height of the crate is half the height of the
             normal CR80D crate.

             The modules of the S crate are connected through
             a Printed Circuit Board (PCB) with 1 row of connectors.
              External connection of power and signal lines
             may be performed both by connection to front mounted
             modules and to rear mounted modules.

         The CAMPS Main Site equipment shown on fig. 4.1.1.2-1
         is separated in two by the horizontal V24-IDF-line.
          Equipment above the IDF line is placed within the
         CAMPS Main Site Racks.  Equipment below the V24-IDF-line
         is placed in the surrounding CAMPS installation as
         appropriate.



















































     Fig. 4.1.1.2-2…01…C̲R̲8̲0̲D̲ ̲P̲r̲o̲c̲e̲s̲s̲o̲r̲ ̲U̲n̲i̲t̲/̲C̲h̲a̲n̲n̲e̲l̲ ̲U̲n̲i̲t̲



















































            Fig. 4.1.1.2-3…01…C̲R̲8̲0̲D̲ ̲W̲a̲t̲c̲h̲d̲o̲g̲ ̲U̲n̲i̲t̲

                             



















































         Fig. 4.1.1.2-4…01…T̲y̲p̲i̲c̲a̲l̲ ̲S̲-̲C̲r̲a̲t̲e̲ ̲A̲s̲s̲e̲m̲b̲l̲y̲



4.1.1.2.2    E̲q̲u̲i̲p̲m̲e̲n̲t̲ ̲M̲a̲t̲r̲i̲x̲

         The design of the equipment supplied for each site
         is identical.  In some details the site equipment will
         be identical and in some parts the site equipment will
         differ due to differences in the connectivity of each
         site.

         The Equipment Matrix, fig. 4.1.1.2-5 shows the items
         to be supplied to each site.

         The matrix does not contain standard items for complete
         assembly of each site equipment, i.e. signal cables,
         power cables, mechanical parts.

         The connectivity of each site is presented in section
         4.1.1.3.2.



4.1.1.3  S̲i̲t̲e̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲ ̲C̲o̲m̲p̲l̲e̲m̲e̲n̲t̲

         The equipment of a typical CAMPS room is shown on fig.
         4.1.1.3-1.

         All sites are equipped with:

         a)  two 3 bay rack assemblies, the computer racks (rack
             A, B, C) and the line termination racks (rack D,
             E, F).

         b)  Engineering Position Equipment.

             1)  1 VDU with keyboard, 1 paper tape reader/paper
                 tape puncher and a printer as free-standing
                 units 

             2)  1 dual Floppy Disk station placed in the computer
                 racks.

         c)  1 storage cabinet.

         d)  A number of supervisor position equipment, each
             composed of 1 Visual Display Unit with keyboard
             and 1 Medium Speed Printer.


















































       FIGURE 4.1.1.2-5…01…MAIN SITES EQUIPMENT MATRIX


















































Fig. 4.1.1.3-1…01…C̲A̲M̲P̲S̲ ̲M̲a̲i̲n̲ ̲S̲i̲t̲e̲ ̲w̲i̲t̲h̲ ̲F̲o̲u̲r̲ ̲S̲u̲p̲e̲r̲v̲i̲s̲o̲r̲ ̲P̲o̲s̲i̲t̲i̲o̲n̲s̲



4.1.1.3.1    M̲a̲i̲n̲ ̲R̲a̲c̲k̲ ̲D̲e̲s̲i̲g̲n̲

         The front elevation of the two rack assemblies of a
         CAMPS Main Site Installation is shown on the figs.
         4.1.1.3-2 and 4.1.1.3-3 (open doors).

         Fig. 4.1.1.3-2 shows the computer racks, named rack
         A, B, and C.

         Fig. 4.1.1.3-3 shows the line termination racks, named
         rack D, E, and F.

         Each rack has a front door and a rear door.

         When the doors of a 3 bay rack assembly are closed,
         the cabinets will form the EMI shielding, to prevent
         compromising emanations.

         The front elevations identify the positions of the
         various crates as defined in section 4.1.1.2.

         The Fan assemblies assure the sufficient cooling of
         the crates and units.

         The air intake is from the front as indicated.  The
         air flows out through the top of each rack.  The front
         doors of the racks are perforated for air intake in
         the two levels of air intake indicated.



















































 Fig. 4.1.1.3-2…01…C̲A̲M̲P̲S̲ ̲M̲a̲i̲n̲ ̲S̲i̲t̲e̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲ ̲F̲r̲o̲n̲t̲ ̲E̲l̲e̲v̲a̲t̲i̲o̲n̲



















































       Fig. 4.1.1.3-3…01…L̲i̲n̲e̲ ̲T̲e̲r̲m̲i̲n̲a̲t̲i̲o̲n̲ ̲R̲a̲c̲k̲s̲ ̲(̲3̲6̲ ̲u̲)̲



4.1.1.3.2    C̲o̲n̲n̲e̲c̲t̲i̲v̲i̲t̲y̲

         The connectivity as described in this section concerns
         the possibilities for connection of the different types
         of terminals and external circuits to each CAMPS Main
         Site equipment.

         Three subsets are addressed:

         a)  Connectivity of VDUs and Medium Speed printers,
             Low Speed Teleprinters, Papertape Reader/Puncher,
             and OCR.

         b)  Connectivity of CCIS, SCARS, and TARE circuitry,
             and terminals (VDU and printer) for S/W development
             in the CSSI site.

         c)  Standard connected peripherals.  This subset includes
             disk drives, floppy disk drives and engineering
             terminals (i.e. VDU and Printer).

         The number of terminals is given for each site and
         the modules/items of the distribution equipment supplied
         for each data exchange channel are given.



4.1.1.3.2.1 V̲D̲U̲s̲ ̲a̲n̲d̲ ̲M̲e̲d̲i̲u̲m̲ ̲S̲p̲e̲e̲d̲ ̲P̲r̲i̲n̲t̲e̲r̲s̲ ̲A̲s̲s̲i̲g̲n̲e̲d̲ ̲f̲o̲r̲ ̲U̲s̲e̲r̲s̲,̲
 
          P̲a̲p̲e̲r̲ ̲T̲a̲p̲e̲ ̲R̲e̲a̲d̲e̲r̲/̲P̲u̲n̲c̲h̲e̲r̲ ̲a̲n̲d̲ ̲O̲C̲R̲.

         These types of terminals are connected to the TDX System
         of the CAMPS Main Site.

         Fig. 4.1.1.3-4 shows the Modules of the TDX Crate assembly.
         In fig 4.1.1.3-4 a front view of the TDX Crate is shown.
         The Crate contains max. 2 LTUX modules each supporting
         max. 4 channels and max. 8 adapters: opto mux/demux
         tranceivers or V28(L) adapters.

         The opto cables leaving the modules of the crate are
         run directly to the connected terminal equipment.


















































                     FIGURE 4.1.1.3-4


         The electrical cables leaving the modules of the crate
         are terminated for external connection in the IDF facility
         in Rack F.

         Fig. 4.1.1.3-5 gives a presentation of:

         a)  the number of terminals supplied for each site.

         b)  the modules/items of the distribution equipment
             supplied for each site.

         c)  the amount of TDX Crates supplied (ready for operation).

         d)  the number of LTUX modules supplied and the application
             of each module.

         Signatures:

         X:      Item mounted

          :      Item not supplied

         O:      Opto mux/demux transceiver mounted

         L:      V24/V28(L) adaptor mounted (i.e. adaptor for
                 electrical low level, limited emanation V24
                 channel transmission)

         VDU:    VDU provided (with opto interface)

         MSP:    Medium Speed printer provided (with opto interface).

         (LSM):  Low Speed media can be connected, but are not
                 delivered (i.e. Point-to-Point, TRC, TTY).

         (OCR):  Optical Character Reader can be connected,
                 but is not delivered.

         PTP/
         PTR:    Paper Tape Reader/Puncher provided.

         (E):    LTUX-modules are mounted for expansion.  (Adaptors
                 shall be decided, when application is decided).
















































Fig. 4.1.1.3-5…01…C̲o̲n̲n̲e̲c̲t̲i̲v̲i̲t̲y̲ ̲(̲V̲D̲U̲s̲,̲ ̲M̲S̲P̲s̲,̲ ̲L̲o̲w̲ ̲S̲p̲e̲e̲d̲ ̲C̲h̲a̲n̲n̲e̲l̲s̲)̲

                        S̲i̲t̲e̲ ̲1̲-̲1̲7̲


4.1.1.3.2.2 E̲x̲t̲e̲r̲n̲a̲l̲ ̲C̲i̲r̲c̲u̲i̲t̲s̲:̲ ̲ ̲C̲C̲I̲S̲,̲ ̲S̲C̲A̲R̲S̲,̲ ̲T̲A̲R̲E̲.̲ ̲ ̲T̲e̲r̲m̲i̲n̲a̲l̲s̲:̲
  
          V̲D̲U̲ ̲a̲n̲d̲ ̲P̲r̲i̲n̲t̲e̲r̲ ̲f̲o̲r̲ ̲S̲/̲W̲ ̲d̲e̲v̲e̲l̲o̲p̲m̲e̲n̲t̲ ̲i̲n̲ ̲t̲h̲e̲ ̲C̲S̲S̲I̲ ̲S̲i̲t̲e̲
         ̲

         These terminals and external circuits are connected
         to the LTUs of the CAMPS Main Site.

         Fig. 4.1.1.3-6 shows the Modules of the Channel Unit
         Assembly.

         The electrical cables leaving the modules of the crate
         are terminated for external connection in the Filter
         Box facility in RACK F.

         Fig. 4.1.1.3-7 gives a presentation of:

         a)  the modules/items of the distribution equipment
             supplied for each site.

         b)  the number of LTU modules supplied, and the application
             of each module.

         The S/W development equipment will be delivered for
         the one site chosen for S/W development (the CSSI site).

         Signatures:

         X:          Item mounted

          :          Item not supplied

         (CCIS):     Specification of the external circuit,
                     
         (SCARS)     which can be connected.
         (TARE)



















































Fig. 4.1.1.3-6 …01…CAMPS, MAIN SITE, PROCESSOR RACKS, CHANNEL UNIT CRATE ELEVATION


















































                      Fig. 4.1.1.3-7
                        Site 1-17



4.1.1.3.2.3 S̲t̲a̲n̲d̲a̲r̲d̲ ̲C̲o̲n̲n̲e̲c̲t̲e̲d̲ ̲P̲e̲r̲i̲p̲h̲e̲r̲a̲l̲s̲

         The standard connected peripherals include:

         a)  Mass storage drives, connected to the Channel Unit
             of the Main Site.

         b)  The Engineering position terminals, i.e. one VDU
             with keyboard and a printer for each site.

         The Engineering position terminals connection are shown
         on fig. 4.1.1.2. (Site Equipment Layout).

         Fig. 4.1.1.3-6 identifies the positions of the Disk
         and Floppy Disk Controllers and Controller adaptors
         in the Channel Unit.

         Fig. 4.1.1.3-8 presents the standard peripherals connected
         into each site equipment.

















































                 Fig. 4.1.1.3-8…01…Site 1-17