             A  P  P  E  N  D  I  X    B


                T̲E̲C̲H̲N̲I̲C̲A̲L̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲



B.1  P̲O̲W̲E̲R̲ ̲I̲N̲P̲U̲T̲


     a) Phases: single- phase supply.

     b) Voltage:

        b1) 3 stabilizer units will be supplied by 240 VAC

        b2) 39 stabilizer units will be supplied by 220
            VAC

        b3) Tolerances:  + 10%/- 15%

     c) Frequency:

        Nominal value: 50 Hz
        Tolerances:    +10/-10%

     d) Harmonic distortion:

        Max. 5%

     e) Transients:

        Non-repetive impulsive interference with a magnitude
        not to exceed 500 volts, pulse rise and fall times
        not faster than 10 microseconds and a total duration
        of maximum 1 millisecond. The available impulse
        energy at the equipment power inlet shall not exceed
        5J.



B.2  P̲O̲W̲E̲R̲ ̲O̲U̲T̲P̲U̲T̲


     a) Each stabilizer unit shall be able to supply one
        disk drive unit during start-up and operation.

     b) Disk drives will be the the following two alternatives,
        both produced by Control Data (CDC, Normandale division)

        b1) SMD 9762, 80mb

        b2) MMD 9730-80





B.3  M̲E̲C̲H̲A̲N̲I̲C̲A̲L̲ ̲D̲E̲S̲I̲G̲N̲

     a) The units shall be for 19 inch rack-mounting

     b) Dimensions:

        Height:         12.22"
        Width:          19"
        Overall length: 22.13"

     c) Acoustic noise level shall be controlled using best
        commercial practice.

     d) A fan shall be included in the unit to provide forced
        cooling, when the unit is in operation



B.4  E̲N̲V̲I̲R̲O̲N̲M̲E̲N̲T̲A̲L̲ ̲C̲O̲N̲D̲I̲T̲I̲O̲N̲S̲

     In designing the equipment to meet the specified requirements
     no account need be taken of catastrophic events such
     as fire, flood, explosion, etc., which are beyond the
     control of an equipment manufacturer.

     The equipment will normally operate within accomodation
     suitable for the operation of similar equipment produced
     for commercial use.

     After initial adjustments have been made, the equipment
     shall maintain normal operation under all specified
     environmental and power supply conditions.

     a) Temperature and humidity

        The equipment shall continue to function when the
        humidity and temperature of its environment are
        within the ranges and cycling specified below.

        The equipment shall continue to operate in a fully
        satisfactory manner even under the worst conditions
        specified below.

        a1) Temperature

            Range:  10 to 40 deg. C
            Change: max. 10 deg. C per hour

        a2) Humidity (relative humidity = RH)

            Range:  40 to 90 per cent RH, non-condensing
            Change: max. 6 per cent RH per hour, non-condensing



        a3) Altitude

            Range:  sea level to 2000 meter

            The equipment shall be so designed that the
            loss of site air conditioning or heating will
            not cause a catastrophic failure within 15 minutes
            after the loss.

     b) Dust, fumes

        The equipment shall be able to operate continuously
        and with normal scheduled preventive maintenance
        in the following air environment:

        b1) Air cleanness

            Particle size      Max Allowable Number
            (Microns)          (particles/cubicmeter)
            -----------------------------------------------

            greater than 5     4 x (10 5)
            greater than 1.5   4 x (10 6)
            greater than 1     4 x (10 7)

        b2) Fumes

            Sulphur dioxide max. 14 ppm.


B.5  P̲R̲O̲T̲E̲C̲T̲I̲O̲N̲ ̲C̲I̲R̲C̲U̲I̲T̲S̲ ̲A̲N̲D̲ ̲F̲R̲O̲N̲T̲ ̲P̲A̲N̲E̲L̲ ̲E̲Q̲U̲I̲P̲M̲E̲N̲T̲



B.5.1   P̲r̲o̲t̲e̲c̲t̲i̲v̲e̲ ̲C̲i̲r̲c̲u̲i̲t̲s̲

     The stabilizer unit shall be equipped with automatic
     overload protection, included short circuit and overtemperature
     protection.  Automatic reset upon overload and overtemperature
     removal.  Automatic shut-down for input overvoltage,
     undervoltage.



B.5.2   F̲r̲o̲n̲t̲ ̲P̲a̲n̲e̲l̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲

     The following features shall be provided on the front
     panel:

     a) Circuit breaker

     b) Lamp indicating ON-condition

     c) Lamp indicating shut-down due to protection circuit

     Power-on light shall be green.
     Shut-down light shall be red.




B.6  P̲A̲C̲K̲A̲G̲I̲N̲G̲

     AC's standard container shall be used.

     It is a wooden container. The unit is supported within
     the container by 8 polystyrene corner blocks.

     The container is re-usable at least once.