⟦22580d8ae⟧ Wang Wps File

    Length: 1905 (0x771)
    Types: Wang Wps File
    Notes: CPS/TCM/033               
    Names: »4329A «

Derivation

└─⟦fa2167417⟧ Bits:30006184 8" Wang WCS floppy, CR 0396A
    └─ ⟦this⟧ »4329A « 

WangText




…02…CPS/TCM/033

…02…JRD/831118…02……02…#
MAP CR8020M/020PC/00, TECHNICAL MANUAL
…02……02…CAMPS









                    T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲

         1 SCOPE ...................................     

         2 CIRR ....................................     

         3 CUSTOMIZING ECO .........................     

         4 MAP CR 8020M TECHNICAL MANUAL ...........     




1.       S̲C̲O̲P̲E̲

         This technical manual contains selected documents and
         drawings describing the MAP CR 8020M/020PC/00 which
         is a dedicated CAMPS module.













2.       C̲O̲N̲F̲I̲G̲U̲R̲A̲T̲I̲O̲N̲ ̲I̲T̲E̲M̲ ̲R̲E̲L̲E̲A̲S̲E̲ ̲R̲E̲C̲O̲R̲D̲












3.       C̲U̲S̲T̲O̲M̲I̲Z̲I̲N̲G̲ ̲E̲C̲O̲

         The MAP module P/N 4.04191-02 is a MAP basic module
         P/N 4.04191-00 which is modified by ECO 813.

         Implementation of ECO 813 produce addressline AD23
         on the P-Bus I/F as well as the C-Bus I/F.

         On the MAP is addressline AD23 generated from the translation
         table signal TT15.

         Provided that ECO 812 and ECO 814 has been implemented
         on the PU-crate and the MBT-1 respectively, will implementation
         of ECO 813 on the MAP module permil addressing a total
         of 2M word memory installed in one PU-crate.

         Memory addressed from 0 to 1 M word must be installed
         in PU-crate positions from 11 to 21 which is enabled
         when AD23 is false.

         Memory addressed from 1 to 2 M word must be installed
         in PU-crate positions from 5 to 10 which is enabled
         when AD23 is true.

         Because AD23 is chosen as enable signal is memory from
         1 to 2 M word addressed as was it installed in crate
         # 8.