DataMuseum.dk

Presents historical artifacts from the history of:

CR80 Wang WCS documentation floppies

This is an automatic "excavation" of a thematic subset of
artifacts from Datamuseum.dk's BitArchive.

See our Wiki for more about CR80 Wang WCS documentation floppies

Excavated with: AutoArchaeologist - Free & Open Source Software.


top - download

⟦2673dc350⟧ Wang Wps File

    Length: 12789 (0x31f5)
    Types: Wang Wps File
    Notes: Spelunked
    Names: »~ORPHAN36.00«

Derivation

└─⟦404706d13⟧ Bits:30006172 8" Wang WCS floppy, CR 0254A
    └─ ⟦this⟧ »~ORPHAN36.00« 

WangText

…0c……00……00……00……00…$…02……00……86…1                                             …02…           …02…   …02…        

     2196/ktd/181A…02…  CPS/TCN/049

…02…  EW/820721…02……02…#

CAMPS SPARE PART DATA BASE   …02……02…  CAMPS












                 CAMPS SPARE PART DATA BASE 



                 CPS/TCN/049       













                 Erik Wunsch         




                 Gert Jensen







                 GJ, OE, FC, EPW                           















                           Logistic Sup-          
                           port Mgr.       …0e…820721…0f…
                                            

             Issue 1    


             820721
                                       




     2196/ktd/181A…02…  CPS/TCN/049

…02…  EW/820721…02……02…2

CAMPS SPARE PART DATA BASE   …02……02…  CAMPS













        820624               All        Issue 1 of document
                     
                                                



                    T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲



         1   SCOPE ...............................   4

         2   DATA BASE SIZE ......................   4

         3   TERMINAL DISPLAY ....................   5

         4   DATA BASE STRUCTUE .................   5
             4.1  SYSTEM .........................   6
             4.2  SITE ...........................   6
             4.3  ASSEMBLY .......................   7
             4.4  SUBASSEMBLY ....................   7
             4.5  PART ...........................   8

         5   RINT OUTPUT ........................   9
             5.1  GENERAL ........................   9
             5.2  EQUIPMENT MATRIX ...............   9
             5.3  SPARE MATRIX (SPL) .............  10
             5.4  SPL CALCULATION ................  13

         6    DATA SEGMENT ......................  15

         7    USERS GUIDE (TBD) ..................  15


                         1  S̲C̲O̲P̲E̲



         This document describes the baseline of the CAMPS SPARE
         PART DATA BASE (CSPDB) which shall handle the spare
         part list for CAMPS

         Three types of spare list will be geerated for CAMPS:

         1.  SITE (1-16)                      (16 lists)
         2.  SUPPLY DEPOTS (1-2)              (one list)
         3.  REPAIR DEPOTS (1-2)              (one list)

         The system IMS at Chr.Rovsing at Marielundsvej will
         be used.









                     2  D̲A̲T̲A̲ ̲B̲A̲E̲ ̲S̲I̲Z̲E̲



         Each item requires allocated storage for:

             11 alphanumeric fields of 17 bytes
             10 numeric fields of 15 digits
              1 alphanumeric field of 80 bytes

         There will be approximately 6000 items with up to 100
         different entity names and fieldheadings.

         5 megabytes are an adequate size for the data base.
         10000 items with 500 bytes each.










                   3  T̲E̲R̲M̲I̲N̲A̲L̲-̲D̲I̲S̲P̲L̲A̲Y̲



         The displayed picture is constructed in such a way
         that all stored information for one item can be displayed
         with entity name and field headings on one pag of the
         screen.

         The terminal must be on-line without restrictions from
         0800 to 1730 hours.










                  4  D̲A̲T̲A̲ ̲B̲A̲S̲E̲ ̲S̲T̲R̲U̲C̲T̲U̲R̲E̲



         The parts that comprise the Data Base have the following
         break down structure

             SYSTEM
             SITE
             ASSEMBLY
             SUBASSEMBLY
             PART



4.1      S̲Y̲S̲T̲E̲M̲

         The S̲Y̲S̲T̲E̲ consists of 16 Sites, 2 supply depots and
         2 repair depots with the following names:

             Site  1:  SHAP               Site  2:  BALT 
              -    3:  NCS                 -    4:  PROT
              -    5:  BOER                -    6:  KANN
              -    7:  RUPP               -   .8:  KOLS
              -    9:  REIT                -   10:  UKAI
              -   11:  WEST                -   12:  DISC
              -   13:  MEON                -   14:  ATHE
              -   15:  SONO                -   16:  NATO
             Supply depot AFCENT:SUPN     Supply depo
                                          AFSOUTH:SUPS
             Repair depot AFCENT:REPN     Repair depot 
                                          AFSOUTH:REPS



4.2      S̲I̲T̲E̲

         Each site is built up of different units with different
         quantities.




4.3      A̲S̲S̲E̲M̲B̲L̲Y̲

         The names of the assemblies are:

             VDU           (Display Terminal)
             STAT.MUX.     (Statistical Multiplexer)
             SMD           (Disk Drive)
             MMD           (  -      )
             FLOP.DISK     (Floppy Disk)
             FREQ.STAB     (Frequency Stabilizer)
             MSP           (Medium Speed Printer)
             PTR/P         (Papertape Reader/Puncher)
             MODEM

             CR80   WATCHDOG
             CR80   PROCESSOR UNIT
             CR80   PERIPHERAL
             CR80   COMMUNICATION
         CR80   TDX SYSTEM
             CR80   SPECIAL
             CR80   RACK, CRATES, ACCESSORIE
             CR80   CABLES
             CR8    MECHANICS

         The units are divided into modules.



4.4      S̲U̲B̲A̲S̲S̲E̲M̲B̲L̲Y̲

         The subassemblies consist of:

             Printed Circuit Boards
             Power Supplies
             Fan Moduls
             Mechanical and Electrical Modules (parts mounted
             on main chassis)
             Camac Modules
             CR80 Modules


         Examples of subassemblies are:

             PMM Board for V.D.U. (pcb)
             IDF Filter
             OMDT-2           (Camac)
             L/L Adapter      (Camac)
             CR80, LTUX
             CR80, BSM-X
             CR80, Watchdog CPU
             tc.

         Subassemblies are built up by parts:



4.5      P̲A̲R̲T̲

         Examples of parts are:

             Resistor          Transistor
             Capacitor         Diode
             Inductor          Integrated Circuit
             Potentiometer     Connector
             Coil              Relay
             Transformer      Switch
             Plug              Mechanical Part
             Socket            Jumper
             Cable             etc.
             CRT-Tube(valve)
             Segment Display


                     5  P̲R̲I̲N̲T̲ ̲O̲U̲T̲P̲U̲T̲



5.1      G̲e̲n̲e̲r̲a̲l̲

         Each page of the printout shall start with a headline
         text followed by all the headings of the column…0e…s which
         may take up two lines.
         The name of he next higher level of the following items
         shall be printed on the first line of the matrix.

         Each item shall only take up one line.

         If a new next higher level is to be printed on the
         same page, an empty line followed by the new level
         name shal be printed.

         The printing facility shall not be less than 131 characters
         per line.

         Examples of the different printout's are shown on fig.5.2-1,
         fig. 5.3-1, fig 5.3-2 and fig.5.3-3.



5.2      E̲Q̲U̲I̲P̲M̲E̲N̲T̲ ̲M̲A̲T̲R̲I̲X̲

         CAMPS has SIX equipment delivered matixes:

             MAIN SITE EQUIPMENT
             CRT MAIN SITE EQUIPMENT
             CRT REMOTE EQUIPMENT
             TARE MAIN EQUIPMENT
             TARE REMOTE EQUIPMENT
             CAMPS SYSTEM EQUIPMENT

         The first column headings of these matrixes are:

             LINE NO
             ITEM DESCRIPTION

         The following coumn headings are the names given in
         4.1.

         An example of the equipment matrix is shown on fig.5.2-1.


         CAMPS SYSTEM EQUIPMENT MATRIX is the matrix sum of
         the five other matrixes.
         The information for the different matrixes are obtained
         from all the files for the units with relevantschemes
         relating to the different sites.



5.3      S̲P̲A̲R̲E̲ ̲M̲A̲T̲R̲I̲X̲ ̲ ̲(̲S̲P̲L̲)̲

         The headline text is:

             SITE XX            or
             SUPPLY DEPOT       or
             REPAIR DEPOT

         The column headings and width of the column's for four
         matrixes with different column sequncies are listed
         on page 13. The printout can be selected between these
         four matrixes, this choice is made as the printer is
         limited to 132 characters per line.
         The first column, LINE NO is not a consecutive sequence
         but is used both as an identifer and as a hierarchy
         for all print out listings. Line numbers from 0001
         to 0999 are used for subassembly and linenumbers from
         1000 to 9999 are used for piece parts.

HEADING OF THE   COLUMN   COLUMN…02…COLUMN…02…COLUMN…02…COLUMN
COLUMN…02…WIDTH…02…SEQUENCE…02…SEQUENCE…02…SEQUENCE…02…SEQUENCE
                 BYTES…02…SITE…02…SUPDEP…02…REPDEP…02…INTERNAL


LINE NO…02… 5          1         1        1         1
ITEM NAME         17         2        2         2          2
TYPE DESCRIPTION  17         3        3         3          3
NATO CODE         14         4        4         4          4      USER
                                                                  CODE 
                                                                       7 
                                                                         5 
                                                                           5 
                                                                             5 
                                                                               -
USER P/N          13         6        6         6          -
TMFG CODE          7         7        7         7          -
TRUE MFG P/N      13         8        8         8          -
MTBF/1000          6                  9         9          5
QTY NHL            5         -        -         -          9
QTY SYS            5         -       10        10         10
QTY SITE           4        10        -         -         11
REC SPA            4        11        -         -         12
ACT SPA            4        12        -         -         13
ACT SPAN           4         -       11        11         14
ACT SPAS           4         -       12        12         15
REP QTY            4         -        -         -         16
ITEM PRICE         8        13       13        13         17
TOTAL PRICE        8        14       14        14         1
MTTR MIN           5         -        -         -          6
NOTES              5         -        -         -         19
P %                3        15       15        15         20
REPAIR LEV/TYPE/M  6         -        -         -          7
ITEM COMPL/TYPE    6         -        -         -          8…86…1       
                                                           …02…   …02…   …02…   …02…
                                                                    
                                                                    
                                                                    
                                                                   
                  The information to the following column's ITEM NAME,
                  DESCRIPTION, NATO CODE, USER CODE, USER P/N, MFG CODE,
                  TRUE MFG P/N and MTBF/1000 are taken from the relevant
                  item files.

                  Th column QTY SYS is calculated by summing the quantity
                  used on the next higher level times the number of this
                  level in the system.

                  The columns RECSPA is the quantity recommended as spares,
                  this quantity is calculated as shown in 5.3.

                  The column CTSPA is the quantity of the actual delivered
                  spares. This number is obtained by either insure or
                  force the calculated quantity and it is a manual choice.

                  As close to the ratio 6 to 10 as possible but with
                  the quantities still as integers the actal spares are
                  divided between the two depots. The program checks
                  that the following statement is true:

                  (QTY.spares) = (QTY. AFCENT) + (QTY.AFSOUT)

                  If the statement is not true, due to manual change,
                  the (QTY AFSOUTH) is automaticly corrected.

The column ITEM PRICE is obtained from item files. As this price is in
 DOLLARS the price is multiplied with the exchange price before the printout.

                  The column TOTAL PRICE is a result of the column ITEM
                  PRICE multiplied with the actual quantity.

A grand total is summed of the column TOTAL PRICE and is written below
 the matrix.

                  Examples of the SPL are shown on fig. 5.3-1, 5.3-2
                  and 5.3-3.


5.4      S̲P̲L̲ ̲C̲A̲L̲C̲U̲L̲A̲T̲I̲O̲N̲

         The data program for SPL shall be made not only to
         handle the CAMPS project but also be so flexible that
         it can handle future requirements.

         The foundations or SPL are the equipment matrixes mentioned
         in 5.2.
         All the information for these matrixes is in the data
         files.

         LOWER       For future requirements there shall be
                     
         PRITORITY   facility to enter and store several of
                     these matrixes of made up examples.There
                     shall be facility for a variable number
                     of sites, supply depots and repair depots.

         The different matrixes shall on request be printed
         partly or fully. Further it shall be possible to add
         two, three or more of the matrixes and to store the
         rsult.

         From each quantity of equipment and for each site or
         depot the number of spares are calculated as "r".

         "r" = the smallest integer for which:

         confidence  ̲ exp (-m) *  

         when:  0   ̲ confidence   ̲ 1

                m = N * …0e… ̲T̲ ̲ ̲…0f…
                        …0e…MTBF

                N = Total quantity of installed equipment

                T = length of period for which stock is required
             
                    in days.

                MTBF = meantime between failures (is obtained
             
                       from the data file) in hours.


         "T", "N" and the chosen "CONFIDENCE" are variables
         which will be entered separately and be printed below
         the matris.

         It shall be possible to either force (reduce) or insure
         (incease) the recommended quantity of spares and the
         result will be presented as the actual spares in the
         column ACT SPA.

         When the actual spares have been decided the actual
         CONFIDENCE for each item is calculated and printed
         in the column P%.

         The mtrixes shall then be stored for later retrieval.
         The DATA BASE shall be able to store a small number
         of these SPL's.

         A grand total in Dollars is calculated as the sum of
         the column TOTAL PRICE and is printed below the matrix.

                 An alternative mthod to calculate the quantity
                 of spares is as following and shall be available:

                 If for instance 10% of the grand total price
                 for the installed equipment is used to buy
                 
  LOWER PRIORITY spares, then all the recommended spares are
                 first set equl zero and the P is calculated.
                 The spare quantity for the item with the lowest
                 P is incremented by one and the unit price
                 for that item is deducted the price to buy
                 spares for, than the new P is calculated and
                 the process is repeated until the avalable
                 price to buy spares for is below zero.


                     6  D̲A̲T̲A̲ ̲S̲E̲G̲M̲E̲N̲T̲

         Each item has a data segment where all the available
         information can be entered in the relevant fields.
         The entity picture form of these data files is shown
         in Fg. 6-1.

         To each data file belongs a relation scheme. This scheme
         is entered with information of the quantity of this
         item used on the next higher level.

         The program shall check for repetition each time a
         new item is about to be entered, and if heitem has
         been created in the file previously only the relation
         scheme will be updated.










                      7  U̲S̲E̲R̲S̲ ̲G̲U̲I̲D̲E̲

         TBD