APPENDIX B…01…TECHNICAL REQUIREMENTS AND SPECIFICATIONS



        T̲E̲C̲H̲N̲I̲C̲A̲L̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲S̲ ̲A̲N̲D̲ ̲S̲P̲E̲C̲I̲F̲I̲C̲A̲T̲I̲O̲N̲S̲



The power line filters to be supplied under this contract shall
 meet the specifications and requirements specified in this appendix.





                 1̲ ̲G̲E̲N̲E̲R̲A̲L̲ ̲S̲P̲E̲C̲I̲F̲I̲C̲A̲T̲I̲O̲N̲



The power line filter is the component through which the power
 lines enters the CAMPS mainframe. It shall be designed to preserve
 the shielding effectiveness of the CAMPS EMI-racks where the
 power lines penetrate the shield while still allowing physical
 access to the power line connections.





                2̲ ̲ ̲M̲E̲C̲H̲A̲N̲I̲C̲A̲L̲ ̲C̲O̲N̲S̲T̲R̲U̲C̲T̲I̲O̲N̲



The power line filter (PLF) is contained within a metal box
 with a cover.

The PLF shall be mounted inside the top or bottom of an EMI-rack
 Fig. 1 (drawing 30-941) shows the layoyt of the top cover plate
 of the EMI-rack. Fig. 2 shows the outline and the constraints
 for the one corner of the Power line Filter Box.



2.1      The PLF-box shall be designed to be placed within the
         zinc plated area at the cover plate, fig. 1.



2.2.     The PLF-box shall be designed to allow for the operating
         curve of fig. 2 by using the model B design of fig.
         2.





2.3      The design shown on fig. 3 is acceptable except for
         the following notes:

         a)  2.2 above shall be incorporated

         b)  Spacing between Amphenol/Tuchel connectors shall
             be increased due to male connector dimension. Minimum
             spacing:    mm.

         c)  Amphenol Tuchel connectors need to be turned 90
             degrees to allow access to lock releace knop on
             male connector.

         d)  The PLF-box shall be constructed from 18 gauge
             (..... inches) steel, zinc plated after fabrication
             to prevent rust and provide a good contact surface
             to the rack cover plate.

             All exterior seamms shall be continuous welded
             and ground smooth to provide effective shielding.

         e)  The removable cover:


               3̲ ̲ ̲E̲L̲E̲C̲T̲R̲I̲C̲A̲L̲ ̲S̲P̲E̲C̲I̲F̲I̲C̲A̲T̲I̲O̲N̲S̲



Operating voltage:                                               220
                                                                 VAC
                                                                 or
                                                                 240
                                                                 VAC
Voltage tolerances:  +10%/-15%

Voltage Rating:      240 VAC line to case
                     415 VAC line to line

Operating Frequency
(Power):             50 Hz
Frequency tolerances:                                            +
                                                                 10%/-10%

Current Rating:      10 Amps RMS continuous for each of the
                     three paired sections.

Dielectric Withstanding
Voltage:             1200 VDC line to case
                     1500 VDC line to line (1 min. at 23…0e…o…0f… C)

Insulation Resistance:                                           5000
                                                                 Megohms
                                                                 minimum
                                                                 (100
                                                                 VDC,
                                                                 23…0e…o…0f…
                                                                 C)

Voltage Drop:                                                    1%
                                                                 maximum
                                                                 
                                                                 full
                                                                 load
                                                                 (10
                                                                 Amps
                                                                 RMS)
                                                                 and
                                                                 unity
                                                                 power
                                                                 factor

R(DC)                0.03 ohms maximum at 23…0e…o…0f… C, each filter
                     section

Temperature Rise     25…0e…o…0f… C maximum at full load

Insertion Loss                                                   In
                                                                 accordance
                                                                 with
                                                                 MIL-STD-220A,
                                                                 full
                                                                 load
                                                                 extended
                                                                 to
                                                                 30
                                                                 KHz.
                                                                 Insertion
                                                                 loss
                                                                 per
                                                                 figure
                                                                 4.





                      4̲ ̲E̲N̲V̲I̲R̲O̲N̲M̲E̲N̲T̲



The DLF shall operate within the specified limits under environmental
 conditions as specified below:



2.1      Ambient temperature range: 0 to 50…0e…o…0f… C.

         Change: max. 10…0e…o…0f… C per hour.



2.2      Humidity: 40 - 90% relative humidity (% RH), non-condensing.



2.3      Altitude: Sea level to 2000 meter.



2.4      D̲U̲S̲T̲,̲ ̲F̲U̲M̲E̲S̲

         The equipment shall be able to operate continuously
         and with normal scheduled preventive maintenance in
         the following air environment:

         a)  A̲i̲r̲ ̲C̲l̲e̲a̲n̲n̲e̲s̲s̲

             Particle Size              Max. Allowable Number
             (̲m̲i̲c̲r̲o̲n̲s̲)̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲(̲P̲a̲r̲t̲i̲c̲l̲e̲s̲/̲C̲u̲b̲i̲c̲m̲e̲t̲e̲r̲)̲

             greater than  5                   4 x 10…0e…5…0f…
             greater than  1.5                 4 x 10…0e…6…0f…
             greater than  1                   4 x 10…0e…7…0f…

         b)  F̲u̲m̲e̲s̲

             Sulphur dioxide max. 14 ppm.