Request for quotation for the supply of 389 VDUs for
NATO Computer Aided Message Processing System (CAMPS).
-------------------------------------------------------------------
You are hereby invited to submit a quotation for the
supply of the above equipment in accordance with the
specifications and conditions stated below.
1 GENERAL TECHNICAL REQUIREMENTS
1.1 TEMPEST REQUIREMENTS
--------------------
The equipment offered shall have obtained a certificate
of compliance with NATO Comsec tempest requirements
from national authorities.
If, however, modifications to a certified standard
version of a piece of equipment, is required in order
to comply with the requirements of this RFQ, it is
acceptable that tempest certification will apply to
the standard version, and only supplementary test data
confirming that the tempest integrity has been maintained
will be required for the modified version.
1.2 POWER INPUT
-----------
The equipment shall be capable of satisfying the specified
performance requirements when operating with the following
power input.
1.2.1 Phases: Single or 3-phase, and ground.
1.2.2 Voltage:
Nominal value: 380/220 VAC
Tolerances: + 10%/-15%
1.2.3 Frequency:
Nominal value: 50 Hz
Tolerances: +5/-5 Hz
1.2.4 Harmonic Distortion: 5%
1.2.5 Transients:
Non-repetitive impulsive inteference with a magnitude
not to exceed 500 volts, pulse rise and fall times
not faster than 10 microseconds and a total duration
of maximum 1 millisecond. The available impulse energy
at the equipment power inlet shall not exceed 5 J.
1.3 ENVIRONMENT
-----------
The equipment shall be capable of satisfying the specified
performance requirements when operating in the following
environment.
1.3.1 Temperature: 10 - 40 degrees celsius
1.3.2 Humidity: 40 - 90% RH, non-condensing
2 SPECIFIC TECHNICAL REQUIREMENTS
The VDUs for the CAMPS system shall have the following
characteristics as a minimum:
a) K̲e̲y̲b̲o̲a̲r̲d̲:̲ Electronic with a Keyboard layout according
to ISO and ECMA standards. The keyboard shall contain
special groups of logically related control keys
e.g. for cursor control, format programming and
main control.
b) S̲c̲r̲e̲e̲n̲:̲ Contains 24 lines of 80 characters. Screen
size 12" or 15" diagonal.The screen shall be flicker
free and the content visible at more than 2 meters
distance. Screen shall be non-reflective. Character
matrix 5 x 9.
c) C̲h̲a̲r̲a̲c̲t̲e̲r̲ ̲C̲o̲d̲e̲:̲ USASCII 7 bit codes, both upper
and lower case standard.
d) E̲d̲i̲t̲i̲n̲g̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲s̲:̲ An extensive set of editing
facilities shall be available e.g.: Insert/Delete
character, Insert/Delete Line; erase screen; cursor
home/up/down/left/right. All editing functions
may be controlled from keyboard or by remote control
by special characters. Cursor address send and
receive.
e) V̲i̲d̲e̲o̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲s̲:̲ Blinking cursor, dual intensity,
blinking character.
f) M̲o̲d̲e̲s̲ ̲o̲f̲ ̲o̲p̲e̲r̲a̲t̲i̲o̲n̲:̲ Roll/page mode. Transmission
may be page, block, line or character transmission.
Protection of selected fields, and reservation
of areas for monitor information shall be possible
when VDU is in page mode.
g) K̲e̲y̲ ̲f̲u̲n̲c̲t̲i̲o̲n̲:̲ The VDU shall be equipped with a
security key function.
h) A̲u̲d̲i̲o̲ ̲A̲l̲a̲r̲m̲: Built-in acoustic signal for alarm
purposes.
i) I̲n̲t̲e̲r̲f̲a̲c̲e̲s̲:̲ Communications interface: Asynchronous
full or half duplex. Baud rate selectable from
50 Bps to 9600 Bps. (1200, 2400 Bps included).
Interface settings are easily changed.
The VDU shall be equipped with both a V24/V28 interface
and a V24/optical interface.
In case the optical interface is not a standard feature
or for reasons of standardization the supplier may
be requested to incorporate a customer supplied V24/optical
interface.
3 DOCUMENTATION AND LOGISTICS REQUIREMENTS
3.1 DOCUMENTATION
-------------
3.1.1 The supplier will be requested to submit documentation
to component level.
3.1.2 The parts list must include manufacturer's part numbers
as well as NATO stock numbers.
3.1.3 The documentation standard and quality shall enable
reproduction and the supplier will be requested to
grant permission to reproduce for the purpose of the
CAMPS programs.
3.2 TRAINING
--------
3.2.1 Self-study training package or other training documentation
must be supplied as part of the contract.
3.3 SERVICEABILITY
--------------
3.3.1 It shall be easy to diagnose and fault-find to module
level. Fault shall be identifiable to a single module.
3.3.2 A thorough and easily understandable checking and calibration
procedure must be supplied with the equipment.
3.3.3 All necessary special tools and special test instruments
should be listed and unit prices quoted.
3.3.4 A recommended spare parts list must be submitted and
a not-to-exceed cost of a 90 days spare stock quoted.
3.3.5 Meantime between failures (MTBF), meantime to repair
(MTTR) as well as down-time must be specified in quotation.
4 GENERAL CONDITIONS
4.1 DELIVERY SCHEDULE
-----------------
Delivery may take place as soon as the supplementary
test data confirming that modifications to the certified
standard version have not compromise the tempest integrety
has been submitted.
4.2 TERMS OF DELIVERY
-----------------
Deliveries shall be made cif CR's facility in Ballerup,
Copenhagen.
Delivery charges should be quoted separately.
4.3 ORIGIN
------
Bidders shall warrant that the supplies are manufactured
in contributing NATO countries (France not contributing).
4.4 WARRANTY
--------
The price should be quoted on basis of a 20 working
days warranty period commencing the 1st working day
after receipt of the VDU's at CR's facility.
Working days during the month of July, and during the
period December 22 thru January 2, as well as National
Danish Holidays should be excluded when determing the
elapse of the warranty period.
Despite the above the supplier assumes full responsibility
that the tempest integrety of the VDU's is not compromised,
unless this is caused by misuse, physical damage or
other unforeseenable events.
4.5 TERMS OF PAYMENT
----------------
Bidders are requested to accept and base their quotation
on payment 120 days from delivery to CR's facility.
4.6 TYPE OF QUOTATION
-----------------
Quotations should be firm fixed prices valid for 90
days from submission of quotation.
Quotations should include all necessary or recommended
accessories.
4.7 SUBMISSION OF QUOTATIONS
------------------------
Quotations should be received by CR no later than December
22, 1980.
Quotations should be sent to:
Christian Rovsing A/S
2, Lautrupvang
DK-2750 Ballerup
Denmark
Att.: Mr. Gert Jensen
4.8 NOTICE TO CR
------------
Pls confirm your intention to quote by telex to CR
(35111 CR DK).
Pls by telex inform of actual submittal of quotation
on date of your submittal.
Hoping that you will accept this invitation, we are looking
forward to receiving your quotation.