⟦294ee9dac⟧ Wang Wps File

    Length: 7455 (0x1d1f)
    Types: Wang Wps File
    Notes: Quotation of 389 VDU's    
    Names: »0407A «

Derivation

└─⟦74b766e5b⟧ Bits:30006076 8" Wang WCS floppy, CR 0033A
    └─ ⟦this⟧ »0407A « 

WangText



  

                          -  #  






         Request for quotation for the supply of 389 VDUs for
         NATO Computer Aided Message Processing System (CAMPS).
-------------------------------------------------------------------



         You are hereby invited to submit a quotation for the
         supply of the above equipment in accordance with the
         specifications and conditions stated below.



            1  GENERAL TECHNICAL REQUIREMENTS



1.1      TEMPEST REQUIREMENTS
         --------------------

         The equipment offered shall have obtained a certificate
         of compliance with NATO Comsec tempest requirements
         from national authorities.

         If, however, modifications to a certified standard
         version of a piece of equipment, is required in order
         to comply with the requirements of this RFQ, it is
         acceptable that tempest certification will apply to
         the standard version, and only supplementary test data
         confirming that the tempest integrity has been maintained
         will be required for the modified version.

1.2      POWER INPUT
         -----------

         The equipment shall be capable of satisfying the specified
         performance requirements when operating with the following
         power input.

1.2.1    Phases: Single or 3-phase, and ground.

1.2.2    Voltage:
                 Nominal value: 380/220 VAC
                 Tolerances:    + 10%/-15%

1.2.3    Frequency:
                 Nominal value: 50 Hz
                 Tolerances:    +5/-5 Hz

1.2.4    Harmonic Distortion: 5%



1.2.5    Transients:

         Non-repetitive impulsive inteference with a magnitude
         not to exceed 500 volts, pulse rise and fall times
         not faster than 10 microseconds and a total duration
         of maximum 1 millisecond. The available impulse energy
         at the equipment power inlet shall not exceed 5 J.

1.3      ENVIRONMENT
         -----------

         The equipment shall be capable of satisfying the specified
         performance requirements when operating in the following
         environment.

1.3.1    Temperature: 10 - 40 degrees celsius

1.3.2    Humidity:    40 - 90% RH, non-condensing



            2  SPECIFIC TECHNICAL REQUIREMENTS



         The VDUs for the CAMPS system shall have the following
         characteristics as a minimum:

         a)  K̲e̲y̲b̲o̲a̲r̲d̲:̲ Electronic with a Keyboard layout according
             to ISO and ECMA standards. The keyboard shall contain
             special groups of logically related control keys
             e.g. for cursor control, format programming and
             main control.

         b)  S̲c̲r̲e̲e̲n̲:̲ Contains 24 lines of 80 characters. Screen
             size 12" or 15" diagonal.The screen shall be flicker
             free and the content visible at more than 2 meters
             distance. Screen shall be non-reflective. Character
             matrix 5 x 9.

         c)  C̲h̲a̲r̲a̲c̲t̲e̲r̲ ̲C̲o̲d̲e̲:̲ USASCII 7 bit codes, both upper
             and lower case standard.

         d)  E̲d̲i̲t̲i̲n̲g̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲s̲:̲ An extensive set of editing
             facilities shall be available e.g.: Insert/Delete
             character, Insert/Delete Line; erase screen; cursor
             home/up/down/left/right. All editing functions
             may be controlled from keyboard or by remote control
             by special characters. Cursor address send and
             receive.

         e)  V̲i̲d̲e̲o̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲s̲:̲ Blinking cursor, dual intensity,
             blinking character.



         f)  M̲o̲d̲e̲s̲ ̲o̲f̲ ̲o̲p̲e̲r̲a̲t̲i̲o̲n̲:̲ Roll/page mode. Transmission
             may be page, block, line or character transmission.
             Protection of selected fields, and reservation
             of areas for monitor information shall be possible
             when VDU is in page mode.

         g)  K̲e̲y̲ ̲f̲u̲n̲c̲t̲i̲o̲n̲:̲ The VDU shall be equipped with a
             security key function.

         h)  A̲u̲d̲i̲o̲ ̲A̲l̲a̲r̲m̲: Built-in acoustic signal for alarm
             purposes.

         i)  I̲n̲t̲e̲r̲f̲a̲c̲e̲s̲:̲ Communications interface: Asynchronous
             full or half duplex. Baud rate selectable from
             50 Bps to 9600 Bps. (1200, 2400 Bps included).
             Interface settings are easily changed.


         The VDU shall be equipped with both a V24/V28 interface
         and a V24/optical interface.

         In case the optical interface is not a standard feature
         or for reasons of standardization the supplier may
         be requested to incorporate a customer supplied V24/optical
         interface.



       3  DOCUMENTATION AND LOGISTICS REQUIREMENTS



3.1      DOCUMENTATION
         -------------

3.1.1    The supplier will be requested to submit documentation
         to component level.

3.1.2    The parts list must include manufacturer's part numbers
         as well as NATO stock numbers.

3.1.3    The documentation standard and quality shall enable
         reproduction and the supplier will be requested to
         grant permission to reproduce for the purpose of the
         CAMPS programs.

3.2      TRAINING
         --------

3.2.1    Self-study training package or other training documentation
         must be supplied as part of the contract.



3.3      SERVICEABILITY
         --------------

3.3.1    It shall be easy to diagnose and fault-find to module
         level.  Fault shall be identifiable to a single module.

3.3.2    A thorough and easily understandable checking and calibration
         procedure must be supplied with the equipment.

3.3.3    All necessary special tools and special test instruments
         should be listed and unit prices quoted.

3.3.4    A recommended spare parts list must be submitted and
         a not-to-exceed cost of a 90 days spare stock quoted.

3.3.5    Meantime between failures (MTBF), meantime to repair
         (MTTR) as well as down-time must be specified in quotation.



                  4  GENERAL CONDITIONS



4.1      DELIVERY SCHEDULE
         -----------------

         Delivery may take place as soon as the supplementary
         test data confirming that modifications to the certified
         standard version have not compromise the tempest integrety
         has been submitted.

4.2      TERMS OF DELIVERY
         -----------------

         Deliveries shall be made cif CR's facility in Ballerup,
         Copenhagen.

         Delivery charges should be quoted separately.

4.3      ORIGIN
         ------

         Bidders shall warrant that the supplies are manufactured
         in contributing NATO countries (France not contributing).



4.4      WARRANTY
         --------

         The price should be quoted on basis of a 20 working
         days warranty period commencing the 1st working day
         after receipt of the VDU's at CR's facility.

         Working days during the month of July, and during the
         period December 22 thru January 2, as well as National
         Danish Holidays should be excluded when determing the
         elapse of the warranty period.

         Despite the above the supplier assumes full responsibility
         that the tempest integrety of the VDU's is not compromised,
         unless this is caused by misuse, physical damage or
         other unforeseenable events.

4.5      TERMS OF PAYMENT
         ----------------

         Bidders are requested to accept and base their quotation
         on payment 120 days from delivery to CR's facility.

4.6      TYPE OF QUOTATION
         -----------------

         Quotations should be firm fixed prices valid for 90
         days from submission of quotation.

         Quotations should include all necessary or recommended
         accessories.

4.7      SUBMISSION OF QUOTATIONS
         ------------------------

         Quotations should be received by CR no later than December
         22, 1980.

         Quotations should be sent to:

         Christian Rovsing A/S
         2, Lautrupvang
         DK-2750 Ballerup
         Denmark
         Att.:  Mr. Gert Jensen





4.8      NOTICE TO CR
         ------------

         Pls confirm your intention to quote by telex to CR
         (35111 CR DK).

         Pls by telex inform of actual submittal of quotation
         on date of your submittal.



Hoping that you will accept this invitation, we are looking
 forward to receiving your quotation.



Yours sincerely,

Christian Rovsing A/S


Gert Jensen