CAMPS SITE LEVEL MAINTENANCE MANUAL
…02…Issue 1…02…CAMPS
WATCHDOG TEST PROCEDURES STEP 3000-4000 (cont'd)
STEP PROCEDURE OBSERVATION/ACTION
̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
2845A/ktd …02…CPS/TCM/005
…02…KJA/830912…02……02…
CAMPS SITE LEVEL MAINTENANCE MANUAL
…02…Issue 1…02…CAMPS
4.3.3.3 W̲a̲t̲c̲h̲d̲o̲g̲ ̲T̲e̲s̲t̲ ̲P̲r̲o̲c̲e̲d̲u̲r̲e̲s̲
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3000 WD TEST ENTRY
The WD monitors and controls
the CAMPS H/W.
If the WD fails, it is automatically
taken out of service and the
objects controlled by the WD
will remain unchanged. The system
S/W will direct the active PU
error messages to the supervisor
report printer.
It is still possible to monitor
and reconfigure the CAMPS system
by LED indication and switchsettings
on the modules.
If the CAMPS system is reconfigured,
it is possible to communicate
with one of the PUs. The reconfiguration
procedure is described in step
3450. The boot and start commands
are not changed if the system
is reconfigured as described
in step 3450.
If the maintenance position VDU
fails, then the WD operation
not involving the VDU and the
printer continues.
If the maintenance position printer
fails, the system S/W directs
the active PU error messages
to the supervisor report printer.
The WD continues operations not
involving the VDU subsystem at
site level.
In case of an error in the WD,
the only remedy is to order a
new WD from the depot.
The test described in this section
of the WD is reduced to a functional
test in order to decide whether
the WD is working or not.
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3005 Analyze the error o If the error report is as follows:
situation
CCBXXX
then
GO TO step 3300
o If there is an error indication
in:
Maint. Pos. VDU - WD - PU
then
GO TO step 3400
o If there is an error indication
in:
Maint. Pos. MSP - WD - PU
then
GO TO step 3500
o If there is discovered an error
in one of the
CONTROL/ASSIGN commands
or
STATUS setup in FORMAT AREA
described in the
Maintenance Position Operation
Manual Doc. No. CPS/OPM/005
then
GO TO step 3600
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3300 Error detected BY WD ENTRY
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3305 Analyze the error o If
one
of
the
following
power
level
error
reports
appears
CCB001
CCB005
CCB007
CCB013
CCB014
CCB016
CCB022
CCB024
then GO TO step 3310
o If one of the following switch
setting reports appears
CCB006
CCB008
CCB011 - CCB012
CCB026
then GO TO step 3315
o If one of the following digital
error reports appears:
CCB018
CCB023
CCB025
then GO TO step 3320
o If one of the following temperature
error reports appears:
CCB003
CCB009
CCB020
then GO TO step 3330
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3310 Check the power o If the power level
is not correct
level in the actual neither on the motherboard
nor on the
crate. The actual CCA (if any) then isolate the
error
steps describing as described in crate check
procedcure.
the power level
test procedure
are listed below.
C̲r̲a̲t̲e̲ ̲ ̲ ̲ ̲S̲t̲e̲p̲
PU 1805
CU 2805
TDX 4805
̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
o If the power level is correct
on the motherbord then it indicates
an error in the WD Subsystem.
Check the cables connected
to the CCBA and the CCA/BSM-X.
Replace the CCA/BSM-X
(if necessary)
If the error still appears
then it indicates an error
in the WD.
Check the WD Crate (refer
to step 3800)
Verify the WD Subsystem
GO TO step 3900.
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3315 Check the switchs- o If the switchsettings
are as described
settings in the in the error report then no
error is
actual crate modules. present.
The switchsset-
tings are des-
cribed in section
4.5.
o If the switchssettings are
not as described in the error
report then it indicates an
error in the WD Subsystem.
Check the cable connectors
to the CCBA and the
CCA/BSMs.
If the error is still present
then the replacement of the
following modules are necessary
in order to isolate the error.
In the PU crate:
CCA/MAP/MIA
In the CU crate:
CCA/CUCP
In the TDX crate:
BSM-X
If the error is still present
then it indicates an error
in the WD.
Check the WD (refer to
step 3800)
Verify the WD Subsystem
GO TO step 3900
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3320 Check the LEDs o If there is no LED
error indication
in the TDX crate in the TDX crate
(ref. to sec.4.5) then
GO TO step 3325
o If there is error indication
then correct it or replace
the failing item (refer to
step 4300).
Verify the WD Subsystem
GO TO step 3900.
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3325 It is necessary to o If it is possible to
execute the tests
test the actual using the WD commands then
the error
TDX crate using has disappeared.
S/W commands and
not the switches Verify the WD Subsystem
on the front of
the BSM-X. GO TO step 3900.
The tests consist of:
TDX-BUS and
LTUX-STATUS
(These tests are
described in
step 4300-4400)
o If it is not possible to run
the tests then isolate the
error as described in the offline
troubleshooting tree.
(refer to step 4300)
o If it is necessary to use the
switches then it indicates
an error in the WD subsystem.
Check the cables connected
to the CCBA and the BSM-X.
Replace the BSM-X
(if necessary)
If the error indication has
not disappeared then
Check the WD
(Refer to step 3800) and
Verify the WD Subsystem
GO TO step 3900
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3330 Check the tempera- o If correct then it
indicates an error
ture level in the in the termostat or in the
WD
actual crate. Subsystem.
The level should
be within the Check that the thermostat
is
range connected and adjusted
properly.
05…0e…0…0f… - 40…0e…0…0f… Replace the thermostat
(if necessary)
If the error has not disappeared
then
Replace the BSM-X/CCA
o If the temperature is out of
range then
Check (and replace) the
FAN and
then
Verify the WD Subsystem
GO TO step 3900.
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3400 Test of the Maint. ENTRY
Pos. VDU-PU
Communication
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3405 Analyze the situ- o If
one
of
the
PUs
is
online
then
the
ation: system is still operating.
GO TO step 3410
o If none of the PUs is online
then
GO TO step 3450
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3410 Check that it is o If correct then
possible to com- GO TO step 3415
municate with
the online PU.
The command is:
PUNno (ENTER)
"no" is the number
of the online PU
(refer to
Doc.No.CPS/OPM/005)
o If it is not possible then
GO TO step 3425
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3415 Check that it is o If correct then
possible to com- GO TO step 3420
municate with
the Standby PU.
The command is:
PUNno
no is the number
of the standby PU
(refer to Doc.No.
CPS/OPM/005)
o If it is not possible
then
GO TO step 3445
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3420 Analyze the situ-
ation: o It is possible to communicate
with both PUs. i.e., the error
indication has disappeared.
Verify the WD Subsystem
GO TO step 3900
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3425 Check that it is o If correct then
possible to com- GO TO step 3430
municate with
the Standby PU
The command is:
PUNno
no is the number
of the PU
(refer to Doc.No.
CPS/OPM/005).
o If it is not correct,
GO TO step 3440.
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3430 The communication o If no error are detected
with the online PU GO TO step 3435
is not correct
and
the communication
with the Standby
PU is correct, i.e.
there is an indi-
cation of an error
in the WD, in the
online PU or in the
cables between the
online PU and the
WD.
Check the actual
cables.
Check the LEDs in
the WD (refer to
sec. 4.5)
o If an error is detected than
correct it or repflace the
failing item and then
Verify the WD Subsystem
GO TO step 3900
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3435 It is necessary to o If correct then it
is now possible
switch the stand- to test the communication between
by PU online be- the Standby PU and the WD.
fore testing the
failing communi- GO TO step 3450
cation between
the WD and the
PU.
Use the command:
WDSW
(refer to Doc.No.
CPS/OPM/005)
o If it is not possible then
there is an error indication
in the WD subsystem.
Check the cables between
the WD crate and the PUs.
Check the WD
(refer to step 3800)
Verify the WD subsystem
GO TO step 3900.
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3440 It is not possible o If
no
errors
are
detected
then
to communicate
with neither the GO TO step 3450
online PU nor the
Standby PU.
This situation in-
dicates that there
is an error in the
WD or in the cables
Maint.Pos.VDU-WD-PUs.
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
* N̲O̲T̲E̲
*
*
*
* If the WD fails then it is automatically taken out
of *
* service and the objects controlled by the WD will
remain *
* unchanged.
*
* The System S/W messages will direct the active PU
messages *
* to the supervisor report printer.
*
* It is still possible to monitor and reconfigure
the *
* the CAMPS system by LED indications and switchssettings
*
* on the modules.
*
*
*
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
Check the cables
between Maint.Pos. VDU -
WD - PUs. (refer to figure
4.3.3.3-1)
Check the LEDs and
front plate
Switches in the
following modules: o If any errors are detected
then correct it or replace
the failing
- MAP item and
- MIA
- CPU Verify the WD Subsystem
- RAM GO TO step 3900
- POWER SUPPLY (PU)
- PU CRATE
- WD CRATE
- WCA
- WPU (LTU)
- ADAPTER OPTO
- VDU
(refer to sec. 4.5)
Figure 4.3.3-1
PU - Maint. Pos. VDU Connection…01……86…1 …02… …02… …02… …02… …02… …02…
3445 The communication o If no errors are detected
with the Standby PU
is not correct GO TO step 3450
and
the communication
with the online PU
is correct, i.e.
there is an indica-
tion of an error in
the WD, in the Standby
PU or in the cables
between the Standby PU
and the WD.
Check the actual
cables.
Check the LEDs in
the WD modules.
(refer to section 4.5)
o If an error is detected then
correct it or replace the failing
item and
then
Verify the WD subsystem
GO TO step 3900.
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3450 * * * * * * * * * * * * * * * * * * * * *
* * * * * * * * * * *
* N̲O̲T̲E̲
*
*
*
* The standby PU (if any) is taken offline and the
Maint. *
* Pos. VDU is connected directly to the offline PU.
(Refer *
* to figure 4.3.3.3-2).
*
*
*
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
Enter the command: o The following output should
appear:
OC D[[[ [ (CR) 07 MAP/BIT: OK
DAMOS BOOTLOADER
on the Maint. Pos. CPU
VDU
If correct then it indicates
an
error in the WD:
Check the WD
(refer to step 3800)
and verify the WD subsystem.
GO TO step 3900
o If the expected output does
not appear then
GO TO step 1200
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
Figure 4.3.3.3-2
Reconfiguration Procedure…86…1 …02… …02… …02… …02… …02… …02…
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3500 Test of the WD - ENTRY
Maint.Pos.MSP
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3505 Check the LEDs in o If
correct
then
the WD crate GO TO step 3510
(refer to sec.
4.5).
Check that the W27
cable from the
WCA to the
Adapter crate is
properly connected.
o If an error is detected then
correct it or replace the failing
item and
Verify the WD crate
GO TO step 3900.
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3510 Disconnect W27 o The following output
should appear
from J4 connector on the MSP
on WCA
See figure 4.3.3.3-4.
Connect the Com. If correct then it indicates
an
Tester as shown error in the WD subsystem
in Figure
4.3.3.3-3
GO TO step 3515
Com. tester o If there is no output on the
setup and pro- MSP then
gramming is
shown in figure GO TO step 3520
4.3.3.3-4
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3515 Connect the cab- o If the configuration
is printed
les as then the error has disappeared.
in the original Verify the WD subsystem
configuration.
GO TO step 3900
Verify that the WD
system is powe-
red up.
Check the LEDs
(refer to sec.4.5)
Print the configu-
ration of the sy-
stem on the MSP.
The command is: PCON
Refer to the
Maintenance Position
Operation Manual
CPS/OPM/005
o If there is no print out on
the MSP then
check the WD crate (incl. modules)
(refer to step 3800) and
Verify the WD Subsystem
GO TO Step 3900
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
Figure 4.3.3.3-3
Com.Tester - MSP Setup…86…1 …02… …02… …02… …02… …02… …02…
Com. Tester Setup, programming and operation
OBS: ent. = ENTER Key
trf. = TRANSFER Key
S̲E̲T̲U̲P̲
Press : SETUP Display:
- : - until ASCIIHX appears - : CODE = ASCIIHX
- : - : BAUD = 1200
- : - : DUPLEX = FULL
- : - : DELAY = 200
- : - :
- : - until ASYNC appears - : SETUP = ASUNC
- : - : BIT/CHAR = 8
- : - :
- : - until EVEN appears - : PARITY = EVEN
- : - : STOPBITS = 1
- : - :
- :[D ent. - : EOF = [D
P̲R̲O̲G̲R̲A̲M̲M̲I̲N̲G̲
Press : PROGRAM Display:
- : CLEAR - :
- : - :
- : - until SEND appears - :
- : 1 ent - : 1 SEND: 1
- : - :
- : - until JUMP appears - :
- : 1 ent - : 2 JUMP - 1
- : PROGRAM Display:
- : - - :
- : CLEAR - :
- : - :
- : [[ trf - : 1M: THE QUICK
O̲P̲E̲R̲A̲T̲I̲O̲N̲
Press : START button The
MSP
will
print
on Com. Tester "THE QUICK BROWN FOX..."
until the STOP button
on the Com. Tester is
pressed.
MSP - Com. Tester test…01…Figure 4.3.3.3-4
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3520 The Com. Tester o If
no
errors
are
detected
then
the
Setup is shown error is isolated to the MSP.
in figure
4.3.3.3-5.
GO TO step 6200
The Com. Tester
is connected to
cable No. W27 and
the loop back Adapter
is connected to one
of the test points
shown in figure
4.3.3.3-6.
o If the testprogram detects
an error then isolate
the error by executing
the loop test to the other
test points.
If Adapter crate error
then
GO TO step 5800
When the error is cleared
Verify the WD
Subsystem
GO TO step 3900
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
COM. Tester Setup, Programming
OBS: ent. = ENTER Key
trf. = TRANSFER Key
S̲E̲T̲U̲P̲:
Press : SETUP Display:
- : until ASCIIHX appears - : CODE = ASCIIHX
- : - : BAUD = 1200
- : - : DUPLEX = FULL
- : - : DELAY = 200
- : - :
- : until ASYNC appears - : SETUP = ASYNC
- : - : BIT/CHAR = 8
- : - :
- : until EVEN appears - : PARITY = EVEN
- : - : STOPBITS = 1
- : - :
- : [D ent. - : EOF = [D
P̲R̲O̲G̲R̲A̲M̲M̲I̲N̲G̲
Press : PROGRAM Display:
- : CLEAR - :
- : - :
- : until SEND appears - :
- : 1 ent - : 1 SEND: 1
- : - :
- : until RECEIVE appears - : 2 RECEIVE
- : - :
- : until COMPARE appears - : 3 COMPARE
- : 1 ent - : 3 COMPARE: 1
- : - :
- : until JUMP EQ appears - :
- : 6 ent - : 4 JUMP EQ 6
- : - :
- : 2 ent - : 5 HALT: 2
- : - :
- : 3 ent - : 6 HALT: 3
Press : PROGRAM Display:
- : - :
- : CLEAR - :
- : - :
- : 43 ent 41 ent 4D ent - : 1M: CAMPS
: 50 ent 53 ent
- : - :
- : 43 ent 4D ent 50 ent 20 ent - : 2M: CMP ̲ERR
45 ent 52 ent 52 ent
- : - :
- : 43 ent 4D ent 50 ent 20 ent - : 3M: CMP OK
4F ent 4B ent
Com. Tester - Loop Back Test Setup…01…Figure 4.3.3.3-5
(1): V24 Loopback Adaptor
(2): V24 Loopback Adaptor
+V24 Monitoring Module
V24 Mon. Module is situated in Slot No. 5, 6.
Note: The OPTO module Slot No. 8 must be removed
before running Loopback test via the V24 Monitoring
Module and V24 Loopback Adaptor.
(3): OPTO Loopback cable
(4): OPTO loopback tube
(5): VDU OPTO: pin 4 - 6
pin 7 - 9
pin 11 - 12
Maint. Pos. MSP - Test Point…01…Figure 4.3.3.3-6
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3600 STATUS: "ERROR" ENTRY
in the FORMAT
AREA describing
the BSM, LTUX,
LTUXL, LTUU,
LTUL or in the
CONTROL/ASSIGN
commands.
(The ERROR and
CONTROL/ASSIGN
commands are
described in the
Maintenance Po-
sition Operation
Manual. Doc.No.
CPS/OPM/005).
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3605 Run the corre- o If it is possible to
execute the tests
sponding off- only using the S/W commands
then
line tests execute a controlled
using the S/W switchover and
commands and repeat the test from
n̲o̲ switches. the other PU.
The appendix C
shows the ENTRY If there is still no errorindication
POINT in the off- then the error has disappeared.
line trouble-
shooting tree. Verify the WD subsystem
GO TO step 3900
o If it is not possible to run
the test neither by S/W comsmands
nor by switches then isolate
the error as described in the
offline troubleshooting tree.
o If it is necessary to use the
switches then it indicates
an error in the WD subsystem.
Check the cables
connected to the
CCBA and the CCA/BSM.
If the error is still present
then the replacement of the
following modules are necessary
in order to isolate the error.
In PU crate:
CCA/MAP/MIA
In CU crate:
CCA/CUCP
In TDX crate:
BSM-X
If the error is still present
then it indicates an error
in the Wd.
Check the WD
(refer to step 3800) and
Verify the WD subsystem
GO TO step 3900
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3800 Test of the WD ENTRY
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3805 Open the doors to o Check that the WD power
LEDs are "ON"
the WD crate in the following modules. (rack
B)
WPU (LTU)
Power Supply (rear crate)
CCBA (rear crate)
WCA (rear crate)
Terminator Board inside WD
Crate
Check FAN
Check fuse on power supply
If correct, continue to step
3810.
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3810 Execute the Built- The TEST LED should
turn "OFF" after
In-Test in the WD 5-10 sec.
LTU:
If correct, continue to step
3815
Turn power OFF/ON on
the WD power Supply
o If the "TEST" LED remains "ON"
it indicates a possible error
in the WPU (LTU) module.
Replace WPU (LTU)
(refer to Section 4.4)
Repeat step 3810.
If the error is not cleared,
then it indicates an error
in the WD crate
Check the WD crate
GO TO step 3815.
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3815 WD Crate Check o This step describes the test
of the WD
procedure crate.
a) Check that
the cables are connected properly
to the modules and there is
no damage on the modules.
b) Remove all front modules
from the WD crate.
c) Check all female connectors
on the motherboard.
d) Remove the WD crate from
the rack. Check Voltage level
(refer to figure 4.3.3.3-7
- 4.3.3.-10).
e) Check that all wires and
connectors are in proper condition
and properly connected (refer
to figure 4.3.3.3-11).
f) Check that it is possible
to seat all modules properly
in the WD crate
If any errors are detected
then correct them or replace
the failing module.
g) Insert the crate in the
rack. Mount the cables.
h) Verify the WD subsystem.
GO TO step 3900.
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
Figure 4.3.3.3-7
WD Crate - Mains Voltage Level …86…1 …02… …02… …02… …02… …02… …02…
Figure 4.3.3.3-8
WD Crate - Power Supply Adjustment…86…1 …02… …02… …02… …02… …02… …02…
Figure 4.3.3.3-9a
WD Crate - Power Supply Cabling…86…1 …02… …02… …02… …02… …02… …02…
Figure 4.3.3.3-9b
WD Crate - Power Supply Cabling (cont'd)…86…1 …02… …02… …02… …02… …02… …02…
Figure 4.3.3.3-9c
WD Crate - Power Supply Cabling (cont'd)…86…1 …02… …02… …02… …02… …02… …02…
Figure 4.3.3.3-10
WD Crate - Fan Power Cabling…86…1 …02… …02… …02… …02… …02… …02…
Figure 4.3.3.3-11
WD Crate - Internal Cabling…86…1 …02… …02… …02… …02… …02… …02…
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3900 WD Verification ENTRY
Test Procedure
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
3905 It is necessary to verify that
the original error indication
is deleted before the troubleshooting
procedure is finished, therefore
1) GO TO the original ENTRY
POINT in the Off-line
Troubleshooting Tree (defined
by the System Troubleshooting
Tree).
2) Verify that it is possible
to execute the described
step-by- step procedures
without detecting any
errors.
3) If no errors are detected
the troubleshooting of
the WD Subsystem is finished.
4) Complete failure report
and logbook (refer to
section 6).