    2845A/ktd  …02…CPS/TCM/005

…02…KJA/830912…02……02… 
CAMPS SITE LEVEL MAINTENANCE MANUAL
…02…Issue 1…02…CAMPS
 
 WATCHDOG TEST PROCEDURES STEP 3000-4000 (cont'd)

 STEP     PROCEDURE                     OBSERVATION/ACTION
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲






    2845A/ktd  …02…CPS/TCM/005

…02…KJA/830912…02……02… 
CAMPS SITE LEVEL MAINTENANCE MANUAL
…02…Issue 1…02…CAMPS




















4.3.3.3    W̲a̲t̲c̲h̲d̲o̲g̲ ̲T̲e̲s̲t̲ ̲P̲r̲o̲c̲e̲d̲u̲r̲e̲s̲



    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

3000                      WD TEST   ENTRY

                          The WD monitors and controls
                          the CAMPS H/W.

                          If the WD fails, it is automatically
                          taken out of service and the
                          objects controlled by the WD
                          will remain unchanged. The system
                          S/W will direct the active PU
                          error messages to the supervisor
                          report printer.

                          It is still possible to monitor
                          and reconfigure the CAMPS system
                          by LED indication and switchsettings
                          on the modules.

                          If the CAMPS system is reconfigured,
                          it is possible to communicate
                          with one of the PUs. The reconfiguration
                          procedure is described in step
                          3450. The boot and start commands
                          are not changed if the system
                          is reconfigured as described
                          in step 3450.

                          If the maintenance position VDU
                          fails, then the WD operation
                          not involving the VDU and the
                          printer continues.

                          If the maintenance position printer
                          fails, the system S/W directs
                          the active PU error messages
                          to the supervisor report printer.
                          The WD continues operations not
                          involving the VDU subsystem at
                          site level.

                          In case of an error in the WD,
                          the only remedy is to order a
                          new WD from the depot.

                          The test described in this section
                          of the WD is reduced to a functional
                          test in order to decide whether
                          the WD is working or not.

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *





3005  Analyze the error   o If the error report is as follows:
                              
    situation                          
                            CCBXXX
                            then

                            GO TO step 3300

                          o If there is an error indication
                            in:

                            Maint. Pos. VDU - WD - PU
                            then

                            GO TO step 3400

                          o If there is an error indication
                            in:

                            Maint. Pos. MSP - WD - PU
                            then

                            GO TO step 3500

                          o If there is discovered an error
                            in one of the

                            CONTROL/ASSIGN commands

                            or

                            STATUS setup in FORMAT AREA
                            described in the 

                            Maintenance Position Operation

                            Manual Doc. No. CPS/OPM/005
                            then

                            GO TO step 3600

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

3300                      Error detected BY WD                     ENTRY

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *



3305                      Analyze the error                        o If
                                                                     one
                                                                     of
                                                                     the
                                                                     following
                                                                     power
                                                                     level
                                                                     error
                                                                     reports
                                                                     appears

                                 CCB001
                                 CCB005
                                 CCB007
                                 CCB013
                                 CCB014
                                 CCB016
                                 CCB022
                                 CCB024

                            then GO TO step 3310

                          o If one of the following switch
                            setting reports appears

                                 CCB006
                                 CCB008
                                 CCB011 - CCB012
                                 CCB026

                            then GO TO step 3315

                          o If one of the following digital
                            error reports appears:

                                 CCB018
                                 CCB023
                                 CCB025

                            then GO TO step 3320

                          o If one of the following temperature
                            error reports appears:

                                 CCB003
                                 CCB009
                                 CCB020

                            then GO TO step 3330
    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


3310          Check the power    o  If the power level
                                    is not correct
    level in the actual     neither on the motherboard
                            nor on the
    crate. The actual       CCA (if any) then isolate the
                            error
    steps describing        as described in crate check
                            procedcure.
    the power level
    test procedure
    are listed below.

    C̲r̲a̲t̲e̲ ̲ ̲ ̲ ̲S̲t̲e̲p̲

    PU        1805
    CU        2805
    TDX       4805
     ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

                          o If the power level is correct
                            on the motherbord then it indicates
                            an error in the WD Subsystem.

                                 Check the cables connected
                                 to the CCBA and the CCA/BSM-X.
                                 Replace the CCA/BSM-X
                                 (if necessary)

                            If the error still appears
                            then it indicates an error
                            in the WD.

                                 Check the WD Crate (refer
                                 to step 3800)
                                 Verify the WD Subsystem
                                 GO TO step 3900.

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *
3315          Check the switchs- o  If the switchsettings
                                    are as described
    settings in the         in the error report then no
                            error is
    actual crate modules.   present.
    The switchsset-
    tings are des-
    cribed in section
    4.5.

                          o If the switchssettings are
                            not as described in the error
                            report then it indicates an
                            error in the WD Subsystem.

                                 Check the cable connectors
                                 to the CCBA and the
                                 CCA/BSMs.

                            If the error is still present
                            then the replacement of the
                            following modules are necessary
                            in order to isolate the error.

                            In the PU crate:

                                 CCA/MAP/MIA

                            In the CU crate:

                                 CCA/CUCP

                            In the TDX crate:

                                 BSM-X

                            If the error is still present
                            then it indicates an error
                            in the WD.

                                 Check the WD (refer to
                                 step 3800)
                                 Verify the WD Subsystem
 
                                 GO TO step 3900


    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *
3320          Check the LEDs     o  If there is no LED
                                    error indication 
    in the TDX crate        in the TDX crate 
    (ref. to sec.4.5)       then 
                                 
                                 GO TO step 3325

                          o If there is error indication
                            then correct it or replace
                            the failing item (refer to
                            step 4300).
                                 Verify the WD Subsystem
                                 GO TO step 3900.

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

3325          It is necessary to o  If it is possible to
                                    execute the tests
    test the actual         using the WD commands then
                            the error
    TDX crate using         has disappeared.
    S/W commands and
    not the switches             Verify the WD Subsystem
    on the front of
    the BSM-X.                   GO TO step 3900.

    The tests consist of:

    TDX-BUS and
    LTUX-STATUS

    (These tests are
    described in
    step 4300-4400)

                          o If it is not possible to run
                            the tests then isolate the
                            error as described in the offline
                            troubleshooting tree.

                                 (refer to step 4300)


                          o If it is necessary to use the
                            switches then it indicates
                            an error in the WD subsystem.

                                 Check the cables connected
                                 to the CCBA and the BSM-X.
                                 Replace the BSM-X
                                 (if necessary)

                            If the error indication has
                            not disappeared then

                                 Check the WD
                                 (Refer to step 3800) and
                                 
                                 Verify the WD Subsystem
                                 GO TO step 3900

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


3330          Check the tempera- o  If correct then it
                                    indicates an error
    ture level in the       in the termostat or in the
                            WD 
    actual crate.           Subsystem.
    The level should             
    be within the                Check that the thermostat
                                 is    
    range                        connected and adjusted
                                 properly.
    05…0e…0…0f… - 40…0e…0…0f…               Replace the thermostat
                                 (if necessary)

                            If the error has not disappeared
                            then

                                 Replace the BSM-X/CCA

                          o If the temperature is out of
                            range then

                                 Check (and replace) the
                                 FAN and

                                 then

                                 Verify the WD Subsystem

                                 GO TO step 3900.

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

3400          Test of the Maint. ENTRY
    Pos. VDU-PU 
    Communication

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *




3405          Analyze the situ-     o                              If
                                                                   one
                                                                   of
                                                                   the
                                                                   PUs
                                                                   is
                                                                   online
                                                                   then
                                                                   the
                                                                   
                                                                   
                                                                   
    ation:                  system is still operating.

                                 GO TO step 3410

                          o If none of the PUs is online
                            then

                                 GO TO step 3450

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

3410          Check that it is   o  If correct then
    possible to com-             GO TO step 3415
    municate with 
    the online PU.
    The command is:

    PUNno (ENTER)

    "no" is the number
    of the online PU
    (refer to
    Doc.No.CPS/OPM/005)

                          o If it is not possible then

                                 GO TO step 3425

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


3415          Check that it is   o  If correct then
    possible to com-             GO TO step 3420
    municate with
    the Standby PU.
    The command is:

    PUNno
    no is the number
    of the standby PU
    (refer to Doc.No.
    CPS/OPM/005)

                          o If it is not possible 
                            then
                                 GO TO step 3445

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

3420          Analyze the situ-
    ation:                o It is possible to communicate
                            with both PUs. i.e., the error
                            indication has disappeared.

                                 Verify the WD Subsystem
                                 GO TO step 3900

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


3425          Check that it is   o  If correct then
    possible to com-             GO TO step 3430
    municate with
    the Standby PU
    The command is:

    PUNno
    no is the number
    of the PU
    (refer to Doc.No.
    CPS/OPM/005).

                          o If it is not correct,
                                 GO TO step 3440.

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *
3430          The communication  o  If no error are detected
    with the online PU           GO TO step 3435
    is not correct
    and
    the communication
    with the Standby
    PU is correct, i.e.
    there is an indi-
    cation of an error
    in the WD, in the
    online PU or in the
    cables between the
    online PU and the
    WD.
    Check the actual
    cables.
    Check the LEDs in
    the WD (refer to
    sec. 4.5)
                          o If an error is detected than
                            correct it or repflace the
                            failing item and then
                                 Verify the WD Subsystem
                                 GO TO step 3900

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


3435          It is necessary to o  If correct then it
                                    is now possible
    switch the stand-       to test the communication between
    by PU online be-        the Standby PU and the WD.
    fore testing the             
    failing communi-             GO TO step 3450
    cation between
    the WD and the
    PU.
    Use the command:

    WDSW

    (refer to Doc.No.
    CPS/OPM/005)

                          o If it is not possible then
                            there is an error indication
                            in the WD subsystem.

                                 Check the cables between
                                 the WD crate and the PUs.
                                 Check the WD
                                 (refer to step 3800)
                                 Verify the WD subsystem
                                 GO TO step 3900.

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


3440          It is not possible    o                              If
                                                                   no
                                                                   errors
                                                                   are
                                                                   detected
                                                                   then
    to communicate
    with neither the             GO TO step 3450
    online PU nor the            
    Standby PU.
    This situation in-
    dicates that there
    is an error in the
    WD or in the cables
    Maint.Pos.VDU-WD-PUs.

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *
    *                     N̲O̲T̲E̲                        
                                     *
    *                                                 
               *
    *  If the WD fails then it is automatically taken out
    of      *
    *  service and the objects controlled by the WD will
    remain   *
    *  unchanged.                                     
               *
    *  The System S/W messages will direct the active PU
    messages *
    *  to the supervisor report printer.              
               *
    *  It is still possible to monitor and reconfigure
    the        *
    *  the CAMPS system by LED indications and switchssettings
       *
    *  on the modules.                                
               *
    *                                                 
               *
    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

    Check the cables
    between Maint.Pos. VDU -
    WD - PUs. (refer to figure
    4.3.3.3-1)

    Check the LEDs and 
    front plate

    Switches in the
    following modules:      o    If any errors are detected
                                 then correct it or replace
                                 the failing 
    -  MAP                       item and 
    -  MIA    
    -  CPU                       Verify the WD Subsystem
    -  RAM                       GO TO step 3900
    -  POWER SUPPLY (PU)
    -  PU CRATE
    -  WD CRATE
    -  WCA
    -  WPU (LTU)
    -  ADAPTER OPTO
    -  VDU

    (refer to sec. 4.5)


















































                   Figure 4.3.3-1
PU - Maint. Pos. VDU Connection…01……86…1    …02…         …02…           …02… …02…    …02…  …02…               
               
3445          The communication  o  If no errors are detected
    with the Standby PU
    is not correct               GO TO step 3450
    and
    the communication 
    with the online PU
    is correct, i.e.
    there is an indica-
    tion of an error in
    the WD, in the Standby
    PU or in the cables
    between the Standby PU
    and the WD.
    Check the actual
    cables.
    Check the LEDs in
    the WD modules.
    (refer to section 4.5)
                          o If an error is detected then
                            correct it or replace the failing
                            item and
                            then
                                 Verify the WD subsystem
                                 GO TO step 3900.

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


3450          * * * * * * * * * * * * * * * * * * * * *
              * * * * * * * * * * *
    *                     N̲O̲T̲E̲                        
                                     *
    *                                                 
               *
    *  The standby PU (if any) is taken offline and the
    Maint.    *
    *  Pos. VDU is connected directly to the offline PU.
     (Refer  *
    *  to figure 4.3.3.3-2).                          
               *
    *                                                 
               *
    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


    Enter the command:    o The following output should
                            appear:

    OC D[[[ [ (CR)          07 MAP/BIT: OK
                            DAMOS BOOTLOADER
    on the Maint. Pos.      CPU 
    VDU
                            If correct then it indicates
                            an
                          error in the WD:
                                 Check the WD
                                 (refer to step 3800)
                                 and verify the WD subsystem.

                                 GO TO step 3900

                          o If the expected output does
                            not appear then

                                 GO TO step 1200

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *



















































                  Figure 4.3.3.3-2
Reconfiguration Procedure…86…1    …02…         …02…           …02… …02…    …02…  …02…                  
            
    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

3500          Test of the WD -      ENTRY
    Maint.Pos.MSP

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *



3505          Check the LEDs in     o                              If
                                                                   correct
                                                                   then
                                                                   
    the WD crate                 GO TO step 3510
    (refer to sec.
    4.5).

    Check that the W27
    cable from the
    WCA to the
    Adapter crate is
    properly connected.

                          o If an error is detected then
                            correct it or replace the failing
                            item and

                                 Verify the WD crate
                                 GO TO step 3900.

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


3510          Disconnect W27     o  The following output
                                    should appear
    from J4 connector       on the MSP
    on WCA
                            See figure 4.3.3.3-4.

    Connect the Com.        If correct then it indicates
                            an
    Tester as shown         error in the WD subsystem
    in Figure               
    4.3.3.3-3 
                                 GO TO step 3515

    Com. tester           o If there is no output on the
    setup and pro-          MSP then
    gramming is           
    shown in figure              GO TO step 3520
    4.3.3.3-4                       

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

3515          Connect the cab-   o  If the configuration
                                    is printed
    les as                  then the error has disappeared.
    in the original              Verify the WD subsystem
    configuration.
                                 GO TO step 3900

    Verify that the WD           
    system is powe-
    red up.

    Check the LEDs
    (refer to sec.4.5)

    Print the configu-
    ration of the sy-
    stem on the MSP.

    The command is: PCON

    Refer to the
    Maintenance Position
    Operation Manual
    CPS/OPM/005
                          o If there is no print out on
                            the MSP then

                            check the WD crate (incl. modules)
                            (refer to step 3800) and
                            Verify the WD Subsystem

                                 GO TO Step 3900

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


















































                  Figure 4.3.3.3-3
Com.Tester - MSP Setup…86…1    …02…         …02…           …02… …02…    …02…  …02…                   
           
Com. Tester Setup, programming and operation

OBS:          ent. = ENTER Key
    trf. = TRANSFER Key

S̲E̲T̲U̲P̲

Press         : SETUP               Display:
  - : -   until ASCIIHX appears    -    : CODE = ASCIIHX
  - :                              -    : BAUD = 1200
  - :                              -    : DUPLEX = FULL
  - :                              -    : DELAY = 200
  - :                              -    :
  - : -   until ASYNC appears      -    : SETUP = ASUNC
  - :                              -    : BIT/CHAR = 8
  - :                              -    :
  - : -   until EVEN appears       -    : PARITY = EVEN
  - :                              -    : STOPBITS = 1
  - :                              -    :
  - :[D ent.                       -    : EOF = [D


P̲R̲O̲G̲R̲A̲M̲M̲I̲N̲G̲

Press         : PROGRAM             Display:
  - : CLEAR                        -    :
  - :                              -    :
  - : -   until SEND appears       -    :
  - : 1 ent                        -    : 1 SEND: 1
  - :                              -    :
  - : -   until JUMP appears       -    : 
  - : 1 ent                        -    : 2 JUMP  -  1

  - : PROGRAM                    Display: 
  - : -                            -    :
  - : CLEAR                        -    :
  - :                              -    : 
  - : [[ trf                       -    : 1M: THE QUICK

O̲P̲E̲R̲A̲T̲I̲O̲N̲

Press         : START button                                       The
                                                                   MSP
                                                                   will
                                                                   print
      on Com. Tester             "THE QUICK BROWN FOX..."
                                 until the STOP button
                                 on the Com. Tester is
                                 pressed.



       MSP - Com. Tester test…01…Figure 4.3.3.3-4



    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

3520                      The Com. Tester                          o If
                                                                     no
                                                                     errors
                                                                     are
                                                                     detected
                                                                     then
                                                                     the
                                                                     
    Setup is shown          error is isolated to the MSP.
    in figure                    
    4.3.3.3-5.
                                    GO TO step 6200

    The Com. Tester
    is connected to
    cable No. W27 and
    the loop back Adapter
    is connected to one
    of the test points
    shown in figure
    4.3.3.3-6.

                            o    If the testprogram detects
                                 an error then isolate
                                 the error by executing
                                 the loop test to the other
                                 test points.

                                 If Adapter crate error
                                 then

                                    GO TO step 5800

                                 When the error is cleared

                                    Verify the WD
                                    Subsystem

                                    GO TO step 3900

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


COM. Tester Setup, Programming

OBS:          ent. = ENTER Key
    trf. = TRANSFER Key
S̲E̲T̲U̲P̲:

Press         : SETUP               Display:
  - :       until ASCIIHX appears  -    : CODE = ASCIIHX
  - :                              -    : BAUD = 1200
  - :                              -    : DUPLEX = FULL
  - :                              -    : DELAY = 200
  - :                              -    :
  - :       until ASYNC appears    -    : SETUP = ASYNC
  - :                              -    : BIT/CHAR = 8
  - :                              -    :
  - :       until EVEN appears     -    : PARITY = EVEN
  - :                              -    : STOPBITS = 1
  - :                              -    :
  - : [D ent.                      -    : EOF = [D

P̲R̲O̲G̲R̲A̲M̲M̲I̲N̲G̲

Press         : PROGRAM             Display:
  - : CLEAR                        -    :
  - :                              -    :
  - :       until SEND appears     -    :
  - : 1 ent                        -    : 1 SEND: 1
  - :                              -    :
  - :       until RECEIVE appears  -    : 2 RECEIVE
  - :                              -    :
  - :       until COMPARE appears  -    : 3 COMPARE
  - : 1 ent                        -    : 3 COMPARE: 1
  - :                              -    :
  - :       until JUMP EQ appears  -    :
  - : 6 ent                        -    : 4 JUMP EQ   6
  - :                              -    :
  - : 2 ent                        -    : 5 HALT: 2
  - :                              -    :
  - : 3 ent                        -    : 6 HALT: 3

Press         : PROGRAM             Display:
  - :                              -    :
  - : CLEAR                        -    :
  - :                              -    :
  - : 43 ent 41 ent 4D ent         -    : 1M: CAMPS
    : 50 ent 53 ent                      
  - :                              -    :
  - : 43 ent 4D ent 50 ent 20 ent  -    : 2M: CMP ̲ERR
      45 ent 52 ent 52 ent
  - :                              -    :
  - : 43 ent 4D ent 50 ent 20 ent  -    : 3M: CMP OK
      4F ent 4B ent

 Com. Tester - Loop Back Test Setup…01…Figure 4.3.3.3-5


























                                     (1): V24 Loopback Adaptor

                                     (2): V24 Loopback Adaptor
                                          +V24 Monitoring Module

                                          V24 Mon. Module is situated in Slot No. 5, 6.

                                          Note: The OPTO module Slot No. 8 must be removed
                                          before running Loopback test via the V24 Monitoring
                                          Module and V24 Loopback Adaptor.

                                     (3): OPTO Loopback cable

                                     (4): OPTO loopback tube

                                     (5): VDU OPTO: pin 4 - 6
                                                    pin 7 - 9
                                                    pin 11 - 12

                    Maint. Pos. MSP - Test Point…01…Figure 4.3.3.3-6


    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *
3600          STATUS: "ERROR"    ENTRY
    in the FORMAT
    AREA describing
    the BSM, LTUX,
    LTUXL, LTUU,
    LTUL or in the
    CONTROL/ASSIGN
    commands.
    (The ERROR and
    CONTROL/ASSIGN
    commands are
    described in the
    Maintenance Po-
    sition Operation
    Manual. Doc.No.
    CPS/OPM/005).

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

3605          Run the corre-     o  If it is possible to
                                    execute the tests
    sponding off-           only using the S/W commands
                            then
    line tests                   execute a controlled
    using the S/W                switchover and
    commands and                 repeat the test from
    n̲o̲ switches.                 the other PU.
    The appendix C
    shows the ENTRY         If there is still no errorindication
    POINT in the off-       then the error has disappeared.
    line trouble-
    shooting tree.               Verify the WD subsystem
                                 GO TO step 3900


                          o If it is not possible to run
                            the test neither by S/W comsmands
                            nor by switches then isolate
                            the error as described in the
                            offline troubleshooting tree.

                          o If it is necessary to use the
                            switches then it indicates
                            an error in the WD subsystem.

                                 Check the cables
                                 connected to the
                                 CCBA and the CCA/BSM.

                            If the error is still present
                            then the replacement of the
                            following modules are necessary
                            in order to isolate the error.

                            In PU crate:

                                 CCA/MAP/MIA

                            In CU crate:

                                 CCA/CUCP

                            In TDX crate:

                                 BSM-X

                            If the error is still present
                            then it indicates an error
                            in the Wd.

                                 Check the WD
                                 (refer to step 3800) and
                                 
                                 Verify the WD subsystem
    
                                 GO TO step 3900

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

3800          Test of the WD     ENTRY

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *



3805          Open the doors to  o  Check that the WD power
                                    LEDs are "ON"
    the WD crate            in the following modules.               (rack
                                                                    B)
                            WPU (LTU)
                            Power Supply (rear crate)
                            CCBA (rear crate)
                            WCA (rear crate)
                            Terminator Board inside WD
                            Crate

                            Check FAN

                            Check fuse on power supply

                            If correct, continue to step
                            3810.

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


3810          Execute the Built-    The TEST LED should
                                    turn "OFF" after 
    In-Test in the WD       5-10 sec.
    LTU:
                            If correct, continue to step
                            3815
    Turn power OFF/ON on    
    the WD power Supply





                          o If the "TEST" LED remains "ON"
                            it indicates a possible error
                            in the WPU (LTU) module.

                                 Replace WPU (LTU)
                                 (refer to Section 4.4)
                                 Repeat step 3810.

                            If the error is not cleared,
                            then it indicates an error
                            in the WD crate

                                 Check the WD crate
                                 GO TO step 3815.

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

3815  WD Crate Check      o This step describes the test
                            of the WD
    procedure               crate.

                            a)  Check that
                             the cables are connected properly
                            to the modules and there is
                            no damage on the modules.

                            b)  Remove all front modules
                            from the WD crate.

                            c)  Check all female connectors
                            on the motherboard.

                            d)  Remove the WD crate from
                            the rack.  Check Voltage level
                            (refer to figure 4.3.3.3-7
                            - 4.3.3.-10). 

                            e)  Check that all wires and
                            connectors are in proper condition
                            and properly connected (refer
                            to figure 4.3.3.3-11).

                            f)  Check that it is possible
                            to seat all modules properly
                            in the WD crate

                            If any errors are detected
                            then correct them or replace
                            the failing module.

                            g)  Insert the crate in the
                            rack.  Mount the cables.

                            h)  Verify the WD subsystem.

                                 GO TO step 3900.

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


















































                  Figure 4.3.3.3-7
WD Crate - Mains Voltage Level …86…1    …02…         …02…           …02… …02…    …02…  …02…               
               
















































                  Figure 4.3.3.3-8
WD Crate - Power Supply Adjustment…86…1    …02…         …02…           …02… …02…    …02…  …02…             
                 
















































                  Figure 4.3.3.3-9a
WD Crate - Power Supply Cabling…86…1    …02…         …02…           …02… …02…    …02…  …02…               
               
















































                  Figure 4.3.3.3-9b
WD Crate - Power Supply Cabling (cont'd)…86…1    …02…         …02…           …02… …02…    …02…  …02…          
                    
















































                  Figure 4.3.3.3-9c
WD Crate - Power Supply Cabling (cont'd)…86…1    …02…         …02…           …02… …02…    …02…  …02…          
                    
















































                  Figure 4.3.3.3-10
WD Crate - Fan Power Cabling…86…1    …02…         …02…           …02… …02…    …02…  …02…                
              


















































                  Figure 4.3.3.3-11
WD Crate - Internal Cabling…86…1    …02…         …02…           …02… …02…    …02…  …02…                 
             
    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

3900  WD Verification     ENTRY
    Test Procedure

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *



3905                        It is necessary to verify that
                            the original error indication
                            is deleted before the troubleshooting
                            procedure is finished, therefore

                          1)     GO TO the original ENTRY
                                 POINT in the Off-line
                                 Troubleshooting Tree (defined
                                 by the System Troubleshooting
                                 Tree).

                          2)     Verify that it is possible
                                 to execute the described
                                 step-by- step procedures
                                 without detecting any
                                 errors.

                          3)     If no errors are detected
                                 the troubleshooting of
                                 the WD Subsystem is finished.

                          4)     Complete failure report
                                 and logbook (refer to
                                 section 6).