WangText

…15……00……00…:…0a…:…0b……00……00…:…0c…:…0f…:…00…:…05…:…06…9…01…8…0c…8…06…7…00…7…05…7…06…6…08…6…0e…6…0f…6 6…05…5…0b…5…0c…5…01…5…02…5…07…4…08…4…0e…4…0f…4…05…4…06…3…0b…3…0c…3…00…3…01…2…0b…2…0c…2 2…05…2…06…1…0d…1…0e…1
1 0…09…0…0a…0…01…0…02…0
0 0…05……86…1       …02…  …02…  …02…  …02…  …02…                 …02…  …02…                        



    2483A/rt …02…   CPS/OPM/002

…02…  CLA/840406…02…
CAMPS SUPERVISOR OPERATION MANUAL
…02…   Issue 3…02…  CAMPS













                CAMPS SUPERVISOR OPERATION MANUAL



                CPS/OPM/002

                CDRL Software Development No. 17A
                Line Item No. 4.3.7










                Carsten Larsen               




                Kurt Nybroe-Nielsen








                SHAPE (1), IJO, URH, JAL, KEJ, LT, NEN, ALG,
                ER[, BJR, KJA, CLA, HAU, NPP, SPN, LU, 
                Conf. Mgmt., QA, GQAR










                                              


                           ILS Manager     840720
                           …0e…Train & Docu.…0f…


          4.1



          840720           Config. Mgr.    840720




     2483A/rt     …02…   CPS/OPM/002

…02…  CLA/840406…02……02… ii
CAMPS SUPERVISOR OPERATION MANUAL
…02…   Issue 3…02…  CAMPS









                                   Her inds`ttes first aid







…0f…     2483A/ktd    …02…  CPS/OPM/002

…02…  CLA/840720…02…iii
 CAMPS SUPERVISOR OPERATIONAL MANUAL
…02…  Issue 4…02…  CAMPS…0e…













         820909                 All     Original issue of
 document

Issue 1  830126  CPS Log.       All     Issue 1 of
                 No. 931              document has been changed
                                      according to SHAPE's
                                      review and issue 4.6
                                      of CPS/230/ICD/0002
                                      Supervisor Commands
                                      and Procedures dated
                                      830727.

Issue 2  831115  CPS Log.     All     Issue 2 of the manual
                                      has
               No. 1255               been changed according
                                      to CPS Log. No. 1255
                                      
                                      and Issue 4.6 of CPS/230/ICD/0002,
                                      830727.


Issue 3  840406  CPS Log.     All     Issue 3 of the manual
                                      has
               No. 1572               been changed according
                                      to CPS Log. No. 1572
                                      and Issue 4.7 of CPS/230/ICD/0002,
                                      840120.

Issue 4  840720  C̲h̲a̲n̲g̲e̲ ̲N̲o̲.̲ ̲1̲

               CPS Log.       Page     Add "List of Important
                 No.1732 and    viii     Illustrations".
               CPS Log.       Page     Last subparagraph
                              changed
               No. 1755       150      "RI-table" to "global
                                       RI-table"



    2483A/rt     …02…   CPS/OPM/002

…02…  CLA/840406…02…     iv
CAMPS SUPERVISOR OPERATION MANUAL
…02…   Issue 3…02…  CAMPS
























                                        This page is 
                                  intentionally left blank



    2483A/rt       …02…   CPS/OPM/002

…02…  CLA/840406…02……02…  v
CAMPS SUPERVISOR OPERATION MANUAL
…02…   Issue 3…02…  CAMPS




                                      T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲



     PREFACE 

     1 INTRODUCTION .................................  
          1

     2 OPERATION ....................................  
          3
       2.1 PRINCIPLE OF OPERATION - VDU .............  
              3
         2.1.1 Display Unit .........................  
                  4
         2.1.2 Keyboard Unit - General Information ..  
                 14
           2.1.2.1 Keyboard Unit - Standard Functions  
                     16
           2.1.2.2 Keyboard Unit - Special Functions   
                     22

       2.2 PRINCIPLE OF OPERATION - MSP .............  
             27
         2.2.1 Controls and Indicators ..............  
                 28
         2.2.2 Paper and Ribbon installation.........  
                 32
         2.2.3 Initial Setup ........................  
                 36

     3 STEP-BY-STEP PROCEDURES ......................  
         45
       3.1 ACCESS PROCEDURES ........................  
             47
         3.1.1 Sign ON ..........................SION  
                 49
         3.1.2 Sign OFF .........................SIOF  
                 55
         3.1.3 High Level Menu ..................ATTN  
                 61
         3.1.4 Supervisor Menu ..................SUPV  
                 67

       3.2 SYSTEM CONTROL ...........................  
             71
         3.2.1 Introduction .........................  
                 71
         3.2.2 System Control Menu ..............SYSC  
                 75
         3.2.3 Device Control .......................  
                 81
           3.2.3.1 Device Control Menu ..........DEVC  
                     81
           3.2.3.2 Terminal Position Control ....TEPC  
                     87
           3.2.3.3 PT/OCR/SATP Control ..........POSC  
                    105
           3.2.3.4 Channel Control ..............CHAC  
                    119

         3.2.4 Addressing Scheme Control ............  
                133
           3.2.4.1 Addressing Scheme Control Menu ADSC 
                    133
           3.2.4.2 Local PLA-Table Update .......LPLT  
                    139
           3.2.4.3 Local RI-Table Update ........LORI  
                    149
           3.2.4.4 SIC-Table Update .............SICT  
                    159
           3.2.4.5 SDL-Table Update .............SDLT  
                    169
           3.2.4.6 SCD-Table Update .............SCDT  
                    179
           3.2.4.7 AIG-Table Update .............AIGT  
                    191
           3.2.4.8 Global PLA-Table Update ......GPLT  
                    205
           3.2.4.9 RI-Table Update ..............RITA  
                    217
           3.2.4.10  Circuit-Table Update .......CIRT  
                      229
           3.2.4.11  SCARS/ACCIS Display-Table 
                     Update......................SCCT  
                      239
           3.2.4.12  Operating Signal-Table Update OPST
                      247
           3.2.4.13  Reorganize All Tables ......REOR  
                      257
           3.2.4.14  Abandon Reorganisation .....ABRO  
                      261



    2483A/rt       …02…   CPS/OPM/002

…02…  CLA/840406…02……02… vi
CAMPS SUPERVISOR OPERATION MANUAL
…02…   Issue 3…02…  CAMPS




         3.2.5 User Profile Update ..............UPUP  
                265
         3.2.6 Queue Control ....................      
                279
           3.2.6.1 Queue Control Menu ...........QUEC  
                    279
           3.2.6.2 Circuit Queue Blocked ........BLCQ  
                    285
           3.2.6.3 Circuit Queue Unblocked ......UBCB  
                    289
           3.2.6.4 Circuit Queue Cancellation ...CACQ  
                    293
           3.2.6.5 Terminal Queue Blocked .......BLTQ  
                    303
           3.2.6.6 Terminal Queue Unblocked .....UBTQ  
                    307
           3.2.6.7 Terminal Queue Cancellation ..CATQ  
                    311
           3.2.6.8 Device Queue Blocked .........BLDQ  
                    321
           3.2.6.9 Device Queue Unblocked .......UBDQ  
                    325
           3.2.6.10  Device Queue Cancellation ..CADQ  
                      329

         3.2.7 Supervisor Print Control .........SUPC  
                339
         3.2.8 Disc Control .........................  
                347
           3.2.8.1 Disc Control Menu ............DISC  
                    347
           3.2.8.2 Off-Load Data ................OFLD  
                    353
           3.2.8.3 Abandon Off-Load .............ABOL  
                    357
           3.2.8.4 Copy System Parameter File ...COPY  
                    361
           3.2.8.5 Off-Line Retrieval Off .......OROF  
                    365
           3.2.8.6 Off-Line Retrieval On ........ORON  
                    369
           3.2.8.7 Off-Line Retrieval Suspend ...ORSU  
                    373
           3.2.8.8 List Volumes Currently in Use VOLI  
                    377
           3.2.8.9 Refuse Mount of Volume .......REMO  
                    381
           3.2.8.10 Mount Volume ................VOMO  
            385
           3.2.8.11 Mount Volume for System Use  VSMO  
            389
           3.2.8.12 Dismount Volume .............VODM  
            393
           3.2.8.13 Name Volume .................VONM  
            397
           3.2.8.14 Volume Delete ...............VODL  
            401

         3.2.9   Command Control ................CMDC  
                  409

         3.2.10  Security Control ...............SECC  
                  419

         3.2.11  Global No. Series Control ..........  
                  429
           3.2.11.1 Global No.Series Control 
                     Menu ...................... GNSC  
            429
           3.2.11.2 System No. Series Control .. NOSC  
            435
           3.2.11.3 Channel No.Series Control .. NOCC  
            445
           3.2.11.4 Transaction No. Series Reset NOTR  
            455

         3.2.12  System Parameter Control .......      
                  459
           3.2.12.1 System Parameter Control 
                    Menu ........................SYPC  
                    459
           3.2.12.2 Print/Punch Parameter 
                    Control .....................PPPC  
                    465
           3.2.12.3 Channel Parameter Control ...CHPC  
            473
           3.2.12.4 ACP127 Parameter Control ....ACPC  
            487
           3.2.12.5  Message Distribution
                     Parameter Control ..........MDPC  
                    497



    2483A/rt       …02…  CPS/OPM/002

…02…  CLA/840406…02… vii
CAMPS SUPERVISOR OPERATION MANUAL
…02…  Issue 3…02…  CAMPS





           3.2.12.6  Special Distribution Parameter 
                     Control ................... SDPC  
                      505
           3.2.12.7  Set Crisis Indicator ON ....CION  
                      513
           3.2.12.8  Set Crisis Indicator OFF....CIOF  
                      517
           3.2.12.9  Set Quiet-Hour Terminal.....SQHT  
                      521
           3.2.12.10 Set Quiet-Hour OFF .........SQHO  
                      525
           3.2.12.11 Set Flash Queue Time Out ...FLQT  
                      529
           3.2.12.12 Close Log CIF ..............LGCL  
                      533
           3.2.12.13 CAMPS De RI Control ........DRIC  
                      537
           3.2.12.14 Statistics Print On ........STON  
                      543
           3.2.12.15 Statistics Print Off .......STOF  
                      547

         3.2.13  System Information Extract .........  
                  551
           3.2.13.1  System Information Extract 
                     Menu .......................SYIE  
                      551
           3.2.13.2  Log Trace ..................LGTR  
                      557
           3.2.13.3  Password List ..............PWLT  
                      565
           3.2.13.4  Queue State Print ..........QSPT  
                      569
           3.2.13.5  User Profile Print .........UPPT  
                      573
           3.2.13.6  Terminal Profile Print .....TPPT  
                      577
           3.2.13.7  Device Profile Print .......DPPT  
                      581
           3.2.13.8  Channel Profile Print ......CPPT  
                      585
           3.2.13.9  Command Print ..............CMPT  
                      589
           3.2.13.10 System Parameter Print .....SPAP  
                      593
           3.2.13.11 Storage Occupancy Request ..STOC  
                      597

         3.2.14  Table Print ........................  
                  601
           3.2.14.1  Table Print Menu ...........TAPR  
                      601
           3.2.14.2  Local PLA-Table Print ......LPLP  
                      607
           3.2.14.3  Local RI-Table Print .......LORP  
                      611
           3.2.14.4  SIC-Table Print ............SICP  
                      615
           3.2.14.5  SDL-Table Print ............SDLP  
                      621
           3.2.14.6  SCD-Table Print ............SCOP  
                      627
           3.2.14.7  AIG-Table Print ............ALGP  
                      631
           3.2.14.8  Global PLA-Table Print .....GPLP  
                      637
           3.2.14.9  RI-Table Print .............RITP  
                      643
           3.2.14.10 Circuit-Table Print ........CIRP  
                      647
           3.2.14.11 SCARS/ACCIS Display Table 
                     Print ......................SCCP  
                      651
           3.2.14.12 Operating Signal Table 
                     Print ......................OPSP  
                      655
           3.2.14.13 Table Status Print .........TSTP  
                      659




    2483A/rt       …02… CPS/OPM/002

…02… CLA/840720…02…   viii
CAMPS SUPERVISOR OPERATION MANUAL
…02… Issue 4…02…  CAMPS




       3.3 ENGINEERING FUNCTIONS ....................  
            663
         3.3.1 Introduction..........................  
                663
         3.3.2 Engineering Menu (Normal Mode) ...SENF  
                665
           3.3.2.1 Perform System Integrity 
                   Check ........................SICH  
                    669
           3.3.2.2 Perform Message Flow Trace 
                   Analysis .....................PMAN  
                    673
           3.3.2.3 Set Disc Threshold Warning 
                   Constants ....................SDTC  
                    677
         3.3.3 Engineering Menu (Restart Mode) ......  
                681
           3.3.3.1 System Queue Cancellation ....SASQ  
                    687
           3.3.3.2 Cancel All Circuit Queues ....CAAC  
                    695
           3.3.3.3 Cancel All Terminal Queues ...CAAT  
                    699
           3.3.3.4 Cancel All Device Queues .....CAAD  
                    703
           3.3.3.5 Circuit Queue Cancellation ...CACQ  
                    707
           3.3.3.6 Terminal Queue Cancellation ..CATQ  
                    709
           3.3.3.7 Device Queue Cancellation ....CADQ  
                    711
           3.3.3.8 CAMPS Go .....................CAGO  
                    713
           3.3.3.9   Queue Status Print .........QSPT  
                      715
           3.3.3.10  Storage Occupancy Print ....STOC  
                      719

     4 ERRORS .......................................  
        723
       4.1 ERROR MESSAGES AND ERROR HANDLING ........  
            724

     5 REPORTS ......................................  
        733
       5.1 REPORTS AND REPORT HANDLING ..............  
            733
         5.1.1 Security Reports .....................  
                735
         5.1.2 Warning Reports ......................  
                737
         5.1.3 Channel Reports ......................  
                739
         5.1.4 Command Completion Reports ...........  
                741

     6 GLOSSARY .....................................  
        743
       6.1 ABBREVATIONS .............................  
            743
       6.2 IDENTIFIERS ..............................  
            749
       6.3 ACTION FIELD DESCRIPTION .................  
            757
       6.4 LIST OF COMMANDS .........................  
            759


           L̲I̲S̲T̲ ̲O̲F̲ ̲I̲M̲P̲O̲R̲T̲A̲N̲T̲ ̲I̲L̲L̲U̲S̲T̲R̲A̲T̲I̲O̲N̲S̲

     Figure 2.1.2-1  Keyboard Unit ..................  
       15
     Figure 2.2.1-1  TCM Controls and Indicators ....  
       29
     Figure 2.2.2-1  Paper and Ribbon Installation ..  
       33
     Figure 2.2.2-2  Paper and Ribbon Installation ..  
       35


                    1  I̲N̲T̲R̲O̲D̲U̲C̲T̲I̲O̲N̲



       The "SUPERVISOR OPERATIONAL MANUAL" is written for
       supervisors of the CAMPS System. It describes in detail
       the procedures and routines necessary to optimize the
       daily operation of the CAMPS System. Descriptions of
       commands, displays, and interpretation of errorcodes
       are also provided.

       The procedures and routines described throughout this
       manual take the form of TRANSACTIONS.

       A transaction is the dialogue which takes place between
       the operator and the CAMPS System to execute a COMMAND.
       The transaction identifies FORMATS and describes the
       specific dialogue associated with each one. In each
       case, a representative picture of the format is provided
       (not to scale) on the right-hand page with a step-by-step
       description of the associated dialogue on the left-hand
       page.

       Each format contains individual fields which are described
       in terms of their elements, possible element values,
       and the validation performed. Where SYSTEM RESPONSE
       MESSAGES are returned as a result of garbled information,
       these are also described.

       Each acronym will be defined the first time it is used.

       For ease of reference, a glossary is provided in section
       6.


1.1    A̲P̲P̲L̲I̲C̲A̲B̲L̲E̲ ̲D̲O̲C̲U̲M̲E̲N̲T̲S̲

       1. CPS/OPM/007
          DELTA DATA 7260T (CIB) OPERATOR's MANUAL…86…1      
          …02…  …02…  …02…  …02…  …02…                 …02…  …02…                    
             
                      2  O̲P̲E̲R̲A̲T̲I̲O̲N̲



2.1    P̲R̲I̲N̲C̲I̲P̲L̲E̲ ̲O̲F̲ ̲O̲P̲E̲R̲A̲T̲I̲O̲N̲ ̲-̲ ̲V̲I̲S̲U̲A̲L̲ ̲D̲I̲S̲P̲L̲A̲Y̲ ̲U̲N̲I̲T̲ ̲(̲V̲D̲U̲)̲

       This section describes the VDU characteristics applicable
       to the USER POSITION. No attempt has been made to describe
       all of the characteristics and functions available
       as these are contained in the DELTA DATA 7260T (C/B)
       OPERATOR'S MANUAL, CPS/OPM/007.



2.1.1    D̲i̲s̲p̲l̲a̲y̲ ̲U̲n̲i̲t̲

         Figure 2.1.1-1 is an illustration of the display screen,
         showing a representative format.

         The VDU screen is divided into two areas; a five line
         VDU header (Figure 2.1.1-1.a) and a 22 line format
         area (Figure 2.1.1-1.b).

         The header contains terminal status information.

         The format area is used by the system to display formats
         and by the operator to enter data.


         V̲D̲U̲ ̲H̲e̲a̲d̲e̲r̲ ̲A̲r̲e̲a̲

         1)  T̲e̲r̲m̲i̲n̲a̲l̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲ (refer to Figure 2.1.1-1.c).

             This describes the transaction in course. It is
             a 25 alpha-numeric field, i.e. "TERMINAL POSITION
             CONTROL".

             It is updated on a per-format basis.

         2)  C̲l̲a̲s̲s̲i̲f̲i̲c̲a̲t̲i̲o̲n̲ (refer to Figure 2.1.1-1.d)

             This relates to the classification of the information
             on the screen. It is a 20 character alpha field.

             Displayed items with the classification identified
             will be updated before the presentation of the
             format.

             For items where the classification will first be
             recognized during validation, it will be updated
             when the subsequent format is displayed.

             The terminal and the operator have in their profile
             a preset highest classification . The default classification
             appearing on the screen is the lower of these two.

             A list of the classification possibilities are
             shown is chapter 6.2 IDENTIFIERS.




















































                      Figure 2.1.1-1


         3)  T̲i̲m̲e̲ (refer to Figure 2.1.1-2.a)

             This is the Time in DATE TIME GROUP format. It
             is a 14 alpha-numeric field containing the Day,
             Hour, Minute, Zone, Month, Year.
             For instance: 192135Z ̲FEB ̲82.

             This field is updated every minute.

         4)  Q̲u̲e̲u̲e̲ ̲I̲n̲f̲o̲r̲m̲a̲t̲i̲o̲n̲ (refer to Figure 2.1.1-2.b)

             Four Queues, one for each print function, are displayed,
             each showing the totals of all messages in the
             respective Queue, awaiting print-out.

             The four Printer Queues are placed in order of
             priority and have the following functions:

             REPR:   Report Print
             SUPR:   Supervisor Print
             STAT:   Statistics Print
             LOGP:   Log Print

             Queue information is updated automatically every
             minute except when FLASH messages are queued which
             causes immediate update and a short audio alarm.

             A Response Queue is displayed showing all items
             queued for Supervisor attention. (RESP).
             This function is only available from the supervisor
             assistent positions (MDCO and MSO).

             A Receive Queue is displayed showing the number
             of comment queued.
             This function is only available from the supervisor
             assistant positions (MDCO and MSO).




















































                      Figure 2.1.1-2


         5)  C̲o̲m̲m̲a̲n̲d̲ ̲L̲i̲n̲e̲ (refer to Figure 2.1.1-3.a)

             The command line will be used for the insertion
             of commands and entry of parameters.

             Commands will be entered by pressing the command
             function key (F1) which will cause the cursor to
             jump to the command line in the header. The operator
             will then enter the command on this line. On pressing
             the ENTER Key, the command will be executed, the
             command line cleared, and the cursor repositioned
             back within the main format area. A command will
             consist of four alpha characters followed by a
             parameter field, if required. Commas or spaces
             will be used as separators, i.e. TEPC,TD.

         6)  R̲e̲s̲p̲o̲n̲s̲e̲ ̲L̲i̲n̲e̲ (refer to Figure 2.1.1-3.b)

             System response messages and replies to commands
             where appropriate will be displayed on the response
             line. It has a maximum length of 70 alpha numeric
             characters.

             Ex: TOO ̲MANY ̲PARAMETERS or UNKNOWN ̲COMMAND.

         7)  S̲y̲s̲t̲e̲m̲ ̲L̲i̲n̲e̲ (refer to Figure 2.1.1-3.c)

             The operator can enter the sign-on command by first
             pressing the SYSTEM function key "ATTN", which
             will cause the cursor to jump to the system line,
             and then enter the command. 

             Security warning and security interrogation is
             also performed via this line. Password or Security
             Code is entered here.

             Password and Security Code will not be displayed
             on the screen.




















































                     Figure 2.1.1-3


         8)  F̲o̲r̲m̲a̲t̲ ̲A̲r̲e̲a̲

             The format area is divided into the margin area
             (refer to Figure 2.1.1-4.a) and the user area (refer
             to Figure 2.1.1-4.b).

             This does not apply to the VDU HEADER AREA, which
             occupies the full 80 character screen width.

         9)  M̲a̲r̲g̲i̲n̲ ̲A̲r̲e̲a̲ (Refer to Figure 2.1.1-4.a)

             The ten character margins used by the system to
             indicate the following:

              1    2    3    4    5    6    7    8    9    10
             
              ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲  ̲ ̲ ̲ ̲  ̲ ̲ ̲ ̲  ̲ ̲ ̲ ̲  ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
             ̲ ̲ ̲

                 ERROR CODE     SPACE     SPACE   TEXT LINE
             
                                 LINE           NUMBER
                                  DESCRIPTOR


             The user area consists of the remaining 70 characters.

         10) L̲i̲n̲e̲ ̲D̲e̲s̲c̲r̲i̲p̲t̲o̲r̲ 

             A line descriptor will be given in the VDU margin
             to indicate to the operator if a line is repeatable
             or not.

         11) E̲r̲r̲o̲r̲ ̲C̲o̲d̲e̲ 

             An error code will be given in the VDU margin to
             indicate to the user if the system has found invalid
             data. You will find a list of the error codes in
             chapter 4 (Error Messages And Error Handling),
             which describes the reason for the errors.          




















































                     Figure 2.1.1-4


         12) F̲i̲e̲l̲d̲ ̲D̲e̲s̲c̲r̲i̲p̲t̲o̲r̲ (Figure 2.1.1-5.a)

             Each data entry field has a descriptor, specifying
             whether the user should input alpha, numeric or
             alphanumeric data, and whether the entry is optional
             or mandatory. This descriptor is visible to the
             user in the form of a symbol preceding each field,
             as a reminder of the type of data required. The
             descriptor will only be given for the first field
             of a series of "identical" fields.

         13) F̲i̲e̲l̲d̲ ̲P̲r̲o̲t̲e̲c̲t̲i̲o̲n̲

             Unprotected data-entry fields are the only part
             of the screen where characters can be written.
             

             If the user does not enter a mandatory field, he
             will be warned by an audiable alarm and the cursor
             will stay in the mandatory field until the user
             enters data.

         14) S̲Y̲M̲B̲O̲L̲S̲ ̲U̲S̲E̲D̲ ̲O̲N̲ ̲V̲D̲U̲ ̲L̲A̲Y̲O̲U̲T̲ ̲F̲O̲R̲M̲S̲

                
             A  = inverse video field or
             a  =    "    "     "
              ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲    = Unprotected data-entry field


             L̲i̲n̲e̲ ̲D̲e̲s̲c̲r̲i̲p̲t̲o̲r̲

             R = Repeatable

             F̲i̲e̲l̲d̲ ̲D̲e̲s̲c̲r̲i̲p̲t̲o̲r̲s̲

             N = Mandatory numeric

             n = Optional numeric

             A = Mandatory alpha

             a = Optional alpha

             D = Mandatory alphanumeric

             d = Optional alphanumeric



















































                     Figure 2.1.1-5


2.1.2    K̲e̲y̲b̲o̲a̲r̲d̲ ̲U̲n̲i̲t̲ ̲-̲ ̲G̲e̲n̲e̲r̲a̲l̲ ̲I̲n̲f̲o̲r̲m̲a̲t̲i̲o̲n̲

         The keyboard is detachable from the VDU and contains
         in addition to the normal typewriter keys, the following
         special key pads:

         a)  The 12-key NUMERIC KEYPAD located to the right
             of the main key group (refer to Figure 2.1.2-1.a).

         b)  The 12-key DISPLAY CONTROL located immediately
             above the numeric pad mentioned above in a) (refer
             to Figure 2.1.2-1.b).

         c)  The 12-key TEXT PROCESSING FUNCTIONS pad is located
             above the main key group to the left of the display
             control pad (refer to Figure 2.1.2-1.c).

         d)  The 10-key EDIT AND CLEAR FUNCTIONS pad is located
             to the left of the text processing pad (refer to
             Figure 2.1.2-1.d).

         e)  The 12-key PROGRAM FUNCTIONS KEYS 1-12 is located
             at the upper left of the keyboard refer to Figure
             2.1.2-1.e).

         f)  The 10-key MISC CONTROL FUNCTIONS pad is located
             to the left of the main key group (refer to Figure
             2.1.2-1.f).

             Besides the normal keyboard functions which are
             described in the 7260T (C/B) Operators Manual,
             there are a number of functions on the keyboard
             which require special explanation. These functions
             are not restricted to only your operating position
             but are valid on all operating positions in the
             CAMPS system).…86…1       …02…  …02…                      
                …02…  …02…                     
 

















































                      Figure 2.1.2-1


         The special functions described in this section falls
         into two main categories described in the following.

         a)  S̲t̲a̲n̲d̲a̲r̲d̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲s̲

         -   Those functions that you enable with standard keys.
             That is to say, functions which are built into
             the VDU by the manufacturer.

         b)  S̲p̲e̲c̲i̲a̲l̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲s̲

         -   Those functions that you enable with the special
             function keys (Fl - F12). These keys are interpreted
             by software in the CAMPS system and is interpreted
             identically from all operating positions.

             Note: Function keys F6 is not used.

         The use of the standard function keys will be explained
         first followed by an explanation of the special function
         keys.



2.1.2.1  K̲e̲y̲b̲o̲a̲r̲d̲ ̲U̲n̲i̲t̲ ̲-̲ ̲S̲t̲a̲n̲d̲a̲r̲d̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲s̲

         1)  E̲n̲t̲e̲r̲ ̲(̲E̲N̲T̲E̲R̲)̲ (Refer to Figure 2.1.2.1-1.a)

             When you press the ENTER key, it causes the contents
             of a single field, a line, a group of lines, or
             a complete format to be sent to the host computer.
             The host itself is programmed to decide which of
             these types of information it requires at that
             precise moment. Do not confuse the ENTER key with
             the RETURN key. When you press RETURN, the cursor
             moves to the first position of the next line if
             it is allowed, but no transmission is made to the
             host.

         2)  N̲e̲x̲t̲ ̲F̲i̲e̲l̲d̲ ̲(̲T̲A̲B̲)̲ (Refer to Figure 2.1.2.1-1.b)

             When you press the TAB key (on the main key pad),
             the cursor moves to the first position of the next
             field where you may write.




















































                     Figure 2.1.2.1-1


         3)  P̲r̲e̲v̲i̲o̲u̲s̲ ̲F̲i̲e̲l̲d̲ ̲(̲B̲A̲C̲K̲-̲T̲A̲B̲)̲ (Refer to Figure 2.1.2.1-2.a)

             When you press the BACK-TAB key (immediately above
             TAB) the cursor moves to the first position of
             the previous field.

         4)  N̲e̲x̲t̲ ̲P̲a̲g̲e̲ ̲(̲P̲A̲G̲E̲ ̲F̲W̲D̲)̲ (Refer to Figure 2.1.2.1-2.b)

             When you press the PAGE FWD key it causes the next
             page of information to be displayed. If the present
             page is the last page, the key has no effect.

         5)  P̲r̲e̲v̲i̲o̲u̲s̲ ̲P̲a̲g̲e̲ ̲(̲P̲A̲G̲E̲ ̲B̲A̲C̲K̲)̲ (Refer to Figure 2.1.2.1-2.c)

             This causes the previous page of information to
             be displayed. If the present page is the first
             page, the key has no effect.

         6)  S̲c̲r̲o̲l̲l̲-̲o̲n̲ ̲(̲S̲C̲R̲O̲L̲L̲ ̲F̲W̲D̲)̲ ̲(Refer to Figure 2.1.2.1-2.d)

             This key allows you to move the display up, one
             line at a time, until the bottom line of stored
             information is reached. 

         7)  S̲c̲r̲o̲l̲l̲ ̲B̲a̲c̲k̲ ̲(̲S̲C̲R̲O̲L̲L̲ ̲B̲A̲C̲K̲)̲ (Refer to Figure 2.1.2.1-2.e)

             This key allows you to move the display down, one
             line at a time, until the first line of information
             is reached. Scrolling is allowed within the confinement
             of the two pages stored and may be regarded as
             a moveable window.





















































                     Figure 2.1.2.1-2


         8)  A̲d̲d̲i̲t̲i̲o̲n̲a̲l̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲s̲ ̲(Refer to Figure 2.1.2.1-3.a
             + 2.1.2.1-3.b)

             The following STANDARD functions differ slightly
             from those just described in that you must press
             two keys to perform the function. In all cases,
             the CONTROL SHIFT on the typewriter key pad must
             be pressed and held down while pressing another
             key on the numeric keypad. These functions are:

             -   Insert field group    (CONTROL 1)
             -   Delete field group    (CONTROL 2)
             -   Insert set            (CONTROL 4)
             -   Delete set            (CONTROL 5)
             -   Delete segment x      (CONTROL 7)
             -   Delete segment x      (CONTROL 8)


         9)  S̲y̲s̲t̲e̲m̲ ̲f̲u̲n̲c̲t̲i̲o̲n̲ ̲K̲e̲y̲ ̲(̲A̲T̲T̲N̲)̲ (Refer to Figure 2.1.2.1-3.c)

             When you press this key your terminal will be logically
             connected to this system, or if already in connection
             with system, the function will change to high-level
             menu. In both cases the cursor will move to the
             system line.





















































                     Figure 2.1.2.1-3


2.1.2.2  K̲e̲y̲b̲o̲a̲r̲d̲ ̲U̲n̲i̲t̲ ̲-̲ ̲S̲p̲e̲c̲i̲a̲l̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲s̲

         The following SPECIAL functions require you to press
         one of the special function keys (F1-12) located on
         the upper left of the keyboard unit (Program Functions
         Keys). The layout of the function keypad is shown in
         the diagram below.

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ^        ^         ^        ^         ^        ^  
              ^
         ^COMMAND ^ INSERT  ^  NOT   ^ DELETE  ^  NOT   ^  NOT
           ^
         ^        ^ (n)LINES^  USED  ^ (n)LINES^  USED  ^  USED
          ^
         ^ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲^
         ^        ^         ^        ^         ^        ^  
              ^
         ^        ^         ^        ^         ^        ^  
              ^
         ^   F1   ^   F2    ^   F3   ^    F4   ^   F5   ^  
         F6   ^
         ^        ^         ^        ^         ^        ^  
              ^
         ^ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲^
         ^        ^         ^        ^         ^        ^  
              ^
         ^        ^         ^        ^         ^        ^  
              ^
         ^   F7   ^   F8    ^   F9   ^    F10  ^   F11  ^  
         F12  ^
         ^        ^         ^        ^         ^        ^  
              ^
         ^ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲^
         ^        ^         ^        ^         ^        ^  
              ^
         ^DISPLAY ^  NOT    ^  NOT   ^  NOT    ^ CANCEL ^ RETURN
         ^
         ^ERROR   ^  USED   ^  USED  ^  USED   ^        ^ TO
             ^
         ^MESSAGE ^         ^        ^         ^        ^ CURRENT^
         ^        ^         ^        ^         ^        ^ MENU
           ^
         ^̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲^̲

         1)  F̲u̲n̲c̲t̲i̲o̲n̲ ̲K̲e̲y̲ ̲F̲1̲ ̲-̲ ̲C̲O̲M̲M̲A̲N̲D̲ (Refer to Figure 2.1.2.2-1.a)

             When you press this function key, the cursor moves
             from its present position to the first field position
             on the command line. You may now type any of the
             four-letter commands (plus parameters if applicable)
             that are valid from your terminal.

         2)  F̲u̲n̲c̲t̲i̲o̲n̲ ̲K̲e̲y̲ ̲F̲2̲ ̲-̲ ̲I̲N̲S̲E̲R̲T̲ ̲(̲n̲)̲ ̲L̲I̲N̲E̲S̲ (Refer to Figure
             2.1.2.2-1.b)

             When you press this function key, the cursor will
             move to the command line where you may now enter
             a number. Entering a 5, for example, will cause
             5 lines to be inserted after the line where you
             activated the function. The cursor is now located
             in the first useable position of the 5 inserted
             lines. …86…1         …02…   …02…   …02…   …02…               …02…  …02…   
                                  


















































                     Figure 2.1.2.2-1


             You may only use this function if the cursor is
             located in a repeatable line. If the number you
             enter on the command line exceeds the permissable
             limit, only the allowed number of lines are inserted.

         3)  F̲u̲n̲c̲t̲i̲o̲n̲ ̲K̲e̲y̲ ̲F̲4̲ ̲-̲ ̲D̲E̲L̲E̲T̲E̲ ̲(̲n̲)̲ ̲L̲I̲N̲E̲S̲ (Refer to Figure
             2.1.2.2-2.a)
             When you press this function key, the cursor will
             move to the command line where you may now enter
             a number. Entering a 4, for example, will cause
             4 lines to be deleted after the line where you
             activated the function. If the number you entered
             on the command line exceeds the permissable limit,
             only the allowed number of lines are deleted. This
             function may be used to delete a sentence or paragraph
             from the text of a message.

         4)  F̲u̲n̲c̲t̲i̲o̲n̲ ̲K̲e̲y̲ ̲F̲7̲ ̲-̲ ̲D̲I̲S̲P̲L̲A̲Y̲ ̲E̲R̲R̲O̲R̲ ̲M̲E̲S̲S̲A̲G̲E̲ (Refer
             to Figure 2.1.2.2-2.b)

             Before you press this function key, the cursor
             must be placed in the field where the system has
             found the garbled information.
             Now you press this function key and the cursor
             returns to the command line where you may now enter
             an error number. This will cause an explanation
             of the error to be printed on the response line.
             The error number must be valid. That is to say,
             only recognised error numbers will be decoded.

         5)  F̲u̲n̲c̲t̲i̲o̲n̲ ̲K̲e̲y̲ ̲F̲1̲1̲ ̲-̲ ̲C̲A̲N̲C̲E̲L̲ (Refer to Figure 2.1.2.2-2.c)

             When you press the function key, the transaction
             currently in progress will be cancelled. All resources
             associated with the cancelled transaction are now
             made available to other users for their transactions.

         6)  F̲u̲n̲c̲t̲i̲o̲n̲ ̲K̲e̲y̲ ̲F̲1̲2̲ ̲-̲ ̲R̲e̲t̲u̲r̲n̲ ̲t̲o̲ ̲C̲U̲R̲R̲E̲N̲T̲ ̲M̲e̲n̲u̲ (Refer
             to Figure 2.1.2.2-2.d)

             When you press this function key, the system will
             return the VDU picture to the MENU which led to
             the presently displayed format.





















































                    Figure 2.1.2.2-2


2.2      P̲R̲I̲N̲C̲I̲P̲L̲E̲ ̲O̲F̲ ̲O̲P̲E̲R̲A̲T̲I̲O̲N̲ ̲-̲ ̲M̲e̲d̲i̲u̲m̲ ̲S̲p̲e̲e̲d̲ ̲T̲e̲l̲e̲-̲P̲r̲i̲n̲t̲e̲r̲
         ̲(̲M̲S̲P̲)̲

         This section describes the Medium Speed Tele-Printer.



2.2.1    C̲o̲n̲t̲r̲o̲l̲s̲ ̲a̲n̲d̲ ̲I̲n̲d̲i̲c̲a̲t̲o̲r̲s̲

         Front Panel Controls and Indicators.

         The Teletypewriter Control Module (TCM) includes controls
         and indicators common to all configurations of the
         equipment. The control layout is shown in Figure 2.2.1-1.
         The front panel of the TCM includes the following controls
         and indicators:


         a.  PAPER OUT Indicator - This indicator illuminates
             when the page printer paper supply is depleted
             (refer to Figure 2.2.1-1.a).

         b.  END OF LINE (EOL) Indicator - This indicator illuminates
             five characters prior to the end of a line (refer
             to Figure 2.2.1-1.b).

         c.  POWER ON (PWR) Indicator - This indicator illuminates
             when power is applied to the equipment (refer to
             Figure 2.2.1-1.c).
             NOTE: The Main Power switch is placed on the back
             of the TCM (refer to Figure 2.2.1-2.e).

         d.  ALARM Audible Indicator - The audio alarm sounds
             upon receipt of a precedence message header (VZCZCXXX
             [[[ (CR) (CR) (LF) Z - where XXX is any three alpha
             characters; [[[ is any three numbers; (CR) is carriage
             return; and (LF) is line feed). The alarm also
             sounds five characters before the end of a line
             feed). (Refer to Figure 2.2.1-1.d).

         e.  AUDIO LEVEL Control - This control varies the sound
             level output of the audio alarm to suit the operating
             environment (refer to Figure 2.2.1-1.e).

         f.  PARITY ERROR Indicator/Control - This indicator
             lights when a received parity error is detected.
             The error indication may be cleared by pressing
             this same button (refer to Figure 2.2.1-1.f).





















































       Figure 2.2.1-1…01…TCM Controls and Indicators


         g.  LINE FEED Control - This control is a pushbutton
             switch which causes the page printer to feed paper
             when the switch is depressed (refer to Figure 2.2.1-2.a).

         h.  FORM FEED Control - This control is a pushbutton
             switch which causes the page printer to advance
             paper to the top of the next form (refer to Figure
             2.2.1-2.b).

         i.  TEST Control/Indicator - Momentary depression causes
             lamp test. Continued depression 5 seconds or longer
             initiates system self-test (refer to Figure 2.2.1-2.c).

         j.  SUSP PRINT Control/Indicator - Changes printer
             line status. When lit, printing is suspended (refer
             to Figure 2.2.1-2.d).

         k.  KEY-LOCK SWITCH - Prevents printing by unauthorized
             persons. Key-lock must be in the ON position for
             the printer to operate (refer to Figure 2.2.1-2.e).


         Rear Panel Control.

         a.  MAIN POWER SWITCH - This switch is a circuit breaker
             type, which will trip when too much current is
             consumed by the MSP. Main power is on, when the
             switch is placed in its up position (refer to Figure
             2.2.1-2.f).…86…1     …02…   …02…                          
             …02…  …02…                     


















































        Figure 2.2.1-2…01…TCM Controls and Indicators


2.2.2    P̲a̲p̲e̲r̲ ̲a̲n̲d̲ ̲R̲i̲b̲b̲o̲n̲ ̲I̲n̲s̲t̲a̲l̲l̲a̲t̲i̲o̲n̲

         Figure 2.2.2-1 illustrates the MSP and the parts which
         are employed by paper installation.

         1)  P̲a̲p̲e̲r̲ ̲I̲n̲s̲t̲a̲l̲l̲a̲t̲i̲o̲n̲

             Install sprocket feed paper in the TCM as follows:

             a.  Open the case cover by depressing both latch
                 release buttons, and press lightly on the cover.
                 The cover will raise approximately 25 degrees
                 due to pressure from a compression spring in
                 the case strut.

             b.  Open both tractor assembly pressure levers
                 and unlock the right tractor assembly so that
                 it is free to slide left or right. 

             c.  Insert paper through the bottom of the case,
                 along the paper path, until the paper passes
                 the platen by one to two inches. Place the
                 left paper edge to the left tractor and close
                 the left pressure lever.

             d.  Move the right tractor assembly left or right
                 until the holes in the paper align with the
                 right tractor. Lock the tractor assembly in
                 place and close its pressure lever.

             e.  Switch ON the power.

                 NOTE: The case cover should not be opened if/when
                 the equipment is in operation.




















































      Figure 2.2.2-1…01…Paper and Ribbon Installation


         Figure 2.2.2-2 illustrates the MSP and the parts which
         are employed by ribbon installation.

         f.  Press the LINE FEED button on the TCM case cover
             to feed the paper until the paper is positioned
             so that the leading edge of the paper has passed
             the printing line approximately one inch (6 line
             feeds if in SINGLE LINE FEED; 3 if in DOUBLE LINE
             FEED).

         g.  Press the FORM FEED button on the TCM case cover.
             The paper should feed one sheet of paper and stop
             in the same position as the previous sheet was
             last positioned by use of the line feed button.

         h.  Guide the paper through the cover opening at the
             viewing window. Close the case cover and secure
             the latches.

         2)  R̲i̲b̲b̲o̲n̲ ̲I̲n̲s̲t̲a̲l̲l̲a̲t̲i̲o̲n̲

             Install the printing ribbon in the printing assembly
             as follows:

             a.  Open the TCM case cover in accordance with
                 steps a and b (paper installation) above.

             b.  Place either ribbon spool onto the ribbon feed
                 assembly. Guide the ribbon from the loose spool
                 around the two nearest ribbon guides, between
                 the platen and print head assembly (paper and
                 printhead assembly if paper is installed),
                 and around the remaining two ribbon guides.
                 Install the loose spool onto the ribbon feed
                 assembly. Take up slack by rotating either
                 spool in the direction the ribbon tightens.

             c.  Guide the printing paper through the cover
                 opening at the viewing window. Close the case
                 cover and secure the latches.

                 NOTE: The case cover should not be opened if/when
                 the equipment is in operation.…86…1       …02…   …02… 
                                        …02…  …02…                 
                    



















































       Figure 2.2.2-2…01…Paper and Ribbon Installation





















































         Figure 2.2.3-1…01…MSP Power Switch ON/OFF





















































       Figure 2.2.3-2…01…TCM Controls and Indicators





















































       Figure 2.2.3-3…01…TCM Controls and Indicators





















































       Figure 2.2.3-4…01…TCM Controls and Indicators


               3  S̲T̲E̲P̲-̲B̲Y̲-̲S̲T̲E̲P̲ ̲P̲R̲O̲C̲E̲D̲U̲R̲E̲S̲

       This paragraph is now for VDU operation.…86…1       …02…  …02…
        …02…  …02…  …02…                 …02…  …02…                     














         THIS PAGE…01…IS …01…INTENTIONALLY LEFT BLANK


3.1      A̲C̲C̲E̲S̲S̲ ̲P̲R̲O̲C̲E̲D̲U̲R̲E̲S̲

         All the normal day-to-day functions and facilities
         available to you are executed by using a series of
         4-letter commands. Access to these commands, as well
         as the subsequent dialogue which takes place after
         command execution, are described in this section.

         This description takes the form of step-by-step procedures,
         numbered in chronological order, explaining what you
         must do; what replies, messages and codes you can expect
         from the system; what further actions are necessary
         and descriptions of error messages associated with
         the particular transaction in progress.

         A transaction is the total process of command execution.
         It consists of your dialogue with the system, the associated
         VDU screen layout, the validation checks performed
         on your entered data and subsequently displayed error
         messages if you made a mistake.

         The menu (or format) presented on the VDU screen consists
         of data written in protected as well as unprotected
         fields. Protected fields are reserved for use by the
         system and you cannot write in them. You can only use
         the unprotected fields for data-entry. After you have
         completed input in one of these fields, you press the
         TAB key and the system will automatically move the
         cursor to the first position of the next field where
         data-entry is allowed. When you have completed your
         input on the VDU keyboard, the system will validate
         or check all your entered data for correctness. Full
         validation only occurs after you have pressed the ENTER
         key while character/number mistakes in the individual
         fields are indicated by an audible alarm and no characters
         will be entered.

         A fold-out block diagram (Figure 3.1-1), which describes
         the possibilities from the supervisor position, is
         placed on the last page of this manual.

         You should use this block diagram in conjunction with
         this manual.



         The supervisor functions are divided into 2 mainfunctions:

         -   SYSTEM CONTROL (SYSC)
         -   ENGINEERING FUNCTION (SENF)

         In the blockdiagram you can see which 4-letter commands
         available below the two mainfunctions and in the introduction
         to the two mainfunctions you will find a table which
         can help you to find the actual part in the manual
         associated with the selected command.

         Therefore, if you pick out a command, you can for quick
         reference look up into the introduction and find the
         actual section which describes the transactions necessary
         to execute exactly this command.

         The PEC (Permissive Entry Code) is a code which you
         can define to protect some of the supervisor commands
         from misuse. In this manual, these commands are described
         as you m̲u̲s̲t̲ enter a PEC together with the command.
         The sence is to show all the commands to which you
         can define a PEC and the actual commands are accompanied
         with a C in the fold-out diagram, too.

         From the beginning it is not necessary to enter a PEC,
         if you make use of these commands, but at the moment
         when you define PEC to a command you must after that
         remember entering the PEC together with the actual
         command.…86…1       …02…   …02…                         …02…  …02…    
                         
3.1.1    S̲i̲g̲n̲ ̲O̲N̲ (SION)

         This section will give you information about how to
         SIGN ON to a terminal.



3.1.2  S̲i̲g̲n̲ ̲O̲F̲F̲ (SIOF)

       This section will give you information about how to
       SIGN OFF at a terminal.



3.1.3  H̲i̲g̲h̲ ̲L̲e̲v̲e̲l̲ ̲M̲e̲n̲u̲

       The menu to this section will give you the possibility
       to select the operator function your require. Also
       supervisor assign and sign off take place in the high
       level menu.

       If you have already started your activities as operator,
       you can always return to the high level menu by pressing
       the Attn-key on the VDU keyboard.


3.1.4  S̲u̲p̲e̲r̲v̲i̲s̲o̲r̲ ̲M̲e̲n̲u̲ (SUPV)

       The menu to this section will give you the possibility
       for selecting between two main menus:

       -   SYSTEM CONTROL

       -   SUPERVISOR ENGINEERING



3.2    S̲Y̲S̲T̲E̲M̲ ̲C̲O̲N̲T̲R̲O̲L̲



3.2.1  I̲n̲t̲r̲o̲d̲u̲c̲t̲i̲o̲n̲

       This section enables you to control the CAMPS System
       by selecting the desirable conditions.

       The system control section is divided into different
       submenus, which can help you to find the actual part
       in the system.

       These actual parts which you want controlled or modified
       can be obtained directly by entering the command which
       connect the part in question.

       The following table is split up into mnemonic commands
       in alphabetic order with their associated description
       and section in this manual.

       These mnemonics are the commands which are practicable
       for System Control.



  M̲N̲E̲M̲O̲N̲I̲C̲   D̲E̲S̲C̲R̲I̲P̲T̲I̲O̲N̲                               S̲E̲C̲T̲I̲O̲N̲

  ABOL       Abandon Off-load                          3.2.8.3
  ABRO       Abandon Reorganization                    3.2.4.14
  ACPC       ACP127 Parameter Control                  3.2.12.4
  ADSC       Addressing Scheme Control Menu            3.2.4.1
  AIGP       AIG Table Print                           3.2.14.7
  AIGT       AIG Table Update                          3.2.4.7
  BLCQ       Block Queue For This Circuit              3.2.6.2
  BLDQ       Block Queue For This Device               3.2.6.8
  BLTQ       Block Queue For This Terminal             3.2.6.5
  CACQ       Circuit Queue Cancellation                3.2.6.4
  CADQ       Device Queue Cancellation                 3.2.6.10
  CATQ       Terminal Queue Cancellation               3.2.6.7
  CHAC       Channel Control                           3.2.3.4
  CHPC       Channel Parameter Control                 3.2.12.3
  CIOF       Set Crisis Indicator Off                  3.2.12.8
  CION       Set Crisis Indicator On                   3.2.12.7
  CIRP       Circuit Table Print                       3.2.14.10
  CIRT       Circuit Table Update                      3.2.4.10
  CMDC       Command Control                           3.2.9
  CMPT       Command Print                             3.2.13.9
  COPY       Copy System Parameter File                3.2.8.4
  CPPT       Channel Profile Print                     3.2.13.8
  DEVC       Device Control Menu                       3.2.3.1
  DISC       Disc Control Menu                         3.2.8.1
  DPPT       Device Profile Print                      3.2.13.7
  FLQT       Set Flash Queue Time Out                  3.2.12.11
  GNSC       Global No Series Control Menu             3.2.11.1
  GPLP       Global PLA Table Print                    3.2.14.8
  GPLT       Global PLA Table Update                   3.2.4.8
  LGTR       Log Trace                                 3.2.13.2
  LORI       Local RI-Table Update                     3.2.4.3
  LORP       Local RI Table Print                      3.2.14.3
  LPLP       Local PLA-Table Print                     3.2.14.2
  LPLT       Local PLA Table Update                    3.2.4.2
  MDPC       Message Distribution Parameter Control    3.2.12.5
  NOCC       Channel No. Series Control                3.2.11.3
  NOSC       System No. Series Control                 3.2.11.2
  NOTR       Transaction No. Series Control            3.2.11.4
  OFLD       Off-load Data                             3.2.8.2
  OPST       Operating Signal Table Update             3.2.4.12
  OROF       Off-line Retrieval Off                    3.2.8.5
  ORON       Off-line Retrieval On                     3.2.8.6
  ORSU       Off-line Retrieval Suspend                3.2.8.7


  M̲N̲E̲M̲O̲N̲I̲C̲   D̲E̲S̲C̲R̲I̲P̲T̲I̲O̲N̲                               S̲E̲C̲T̲I̲O̲N̲

  POSC       PT/OCR/SATP Contrtol                      3.2.3.3
  PPPC       Print/Punch Parameter Control             3.2.12.2
  PWLT       Password List                             3.2.13.3
  QSPT       Queue State Print                         3.2.13.4
  QUEC       Queue Control Menu                        3.2.6.1
  REMO       Refuse Mount Of Volume                    3.2.8.9
  REOR       Reorganize All Tables                     3.2.4.13
  RITA       RI-Table Update                           3.2.4.9
  RITP       RI-Table Print                            3.2.14.9
  SCCP       Display Table Print                       3.2.14.11
  SCCT       Display Table Updata                      3.2.4.11
  SCDP       SCD-Table Print                           3.2.14.6
  SCDT       SCD-Table Update                          3.2.4.6
  SDLP       SDL-Table Print                           3.2.14.5
  SDLT       SDL-Table Update                          3.2.4.5
  SDPC       Special Distribution Parameter Control    3.2.12.6
  SECC       Security Control                          3.2.10
  SICP       SIC-Table Print                           3.2.14.4
  SICT       SIC-Table Update                          3.2.4.4
  SPAP       System Parameter Print                    3.2.13.10
  SQHO       Set Quiet Hour Off                        3.2.12.10
  SQHT       Set Quiet Hour Terminal                   3.2.12.9
  STOC       Storage Occupancy Request                 3.2.13.11
  SUPC       Supervisor Print Control                  3.2.7
  SYIE       System Information Extract Menu           3.2.12.1
  SYPC       System Parameter Control Menu             3.2.6.1
  SYSC       System Control Menu                       3.2.2
  TAPR       Table Print Menu                          3.2.14.1
  TEPC       Terminal Position Control                 3.2.3.2
  TPPT       Terminal Profile Print                    3.2.13.6
  TSTP       Table Status Print                        3.2.14.13
  UBCQ       Unblock Queue For This Circuit            3.2.16.3
  UBDQ       Unblock Queue For This Device             3.2.16.9
  UBTQ       Unblock Queue For This Terminal           3.2.16.6
  UPPT       User Profile Print                        3.2.13.5
  UPUP       User Profile Update                       3.2.5
  VODL       Volume Delete                             3.2.8.14
  VODM       Dismount Volume                           3.2.8.12
  VOLI       List Volumes Currently In Use             3.2.8.8
  VOMO       Mount Volume                              3.2.8.10
  VONM       Name Volume                               3.2.8.13
  VSMO       Mount Volume For System Use               3.2.8.11



3.2.2  S̲y̲s̲t̲e̲m̲ ̲C̲o̲n̲t̲r̲o̲l̲ ̲M̲e̲n̲u̲ (SYSC)

       The menu to this section will give you the possibility
       for control of the system.

       The control will in most cases go through further sub-menus.



3.2.3  D̲e̲v̲i̲c̲e̲ ̲C̲o̲n̲t̲r̲o̲l̲



3.2.3.1    D̲e̲v̲i̲c̲e̲ ̲C̲o̲n̲t̲r̲o̲l̲ ̲M̲e̲n̲u̲ (DEVC)

       The menu to this section will give you the possibility
       for control of all types of devices like:

       -   VDUs

       -   PRINTERS

       -   CHANNELS



3.2.3.2    T̲e̲r̲m̲i̲n̲a̲l̲ ̲P̲o̲s̲i̲t̲i̲o̲n̲ ̲C̲o̲n̲t̲r̲o̲l̲ (TEPC)



       TERMINAL POSITION CONTROL is part of the device control.

       This section enables you to:

       -    Block or Unblock Terminals. 

       -   Decide maximum classification plus special handling
           categories which may be handled on the terminals.

       -   Decide terminal capability and the operators who
           may sign in at the terminals.

       You cannot change the data in a user terminal profile
       without having blocked the actual terminal first.

       The system will not accept blocking a supervisor terminal.
       Therefore, you will be able to change data in supervisor
       terminals without blocking.

       In the format, you can jump forward or backward by
       moving the cursor to the desirable entries.

       After validation, if the system finds an invalid entry,
       an error message number will appear in the left hand
       margin on a level with the field in question.
       The actual field will be highlighted (reversed video).

       You must correct your mistake by inserting valid data.

       If you need further error number explanation, proceed
       to the error messages and error handling section.



3.2.3.3  P̲T̲/̲O̲C̲R̲/̲S̲A̲P̲T̲ ̲C̲o̲n̲t̲r̲o̲l̲ (POSC)



         PT/OCR/SAPT CONTROL is part of the device control.

         This section enables you to:

         -   Connect or Disconnect Devices.

         -   Decide maximum classification which may be handled
             on the devices.

         In the format, you can jump forward or backward by
         moving the cursor to the desirable entries.

         After validation, if the system finds an invalid entry,
         an error message number will appear in the left hand
         margin on a level with the field in question.
         The actual field will be highlighted (reversed video).

         You must correct your mistake by inserting valid data.

         If you need further error number explanation, proceed
         to the error messages and error handling section.



3.2.3.4  C̲h̲a̲n̲n̲e̲l̲ ̲C̲o̲n̲t̲r̲o̲l̲ (CHAC)



         CHANNEL CONTROL is part of the device control.

         A channel is used to connect CAMPS to other systems.

         This section enables you to:

         -   Connect of Disconnect specified channel types

         -   Open or Close for incoming traffic.

         In the format, you can jump forward or backward by
         moving the cursor to the desirable entries.

         After validation, if the system finds an invalid entry,
         an error message number will appear in the left hand
         margin on a level with the field in question.
         The actual field will be highlighted (reversed video).

         You must correct your mistake by inserting valid data.

         If you need further error number explanation, proceed
         to the error messages and error handling section.



3.2.4    A̲d̲d̲r̲e̲s̲s̲i̲n̲g̲ ̲S̲c̲h̲e̲m̲e̲ ̲C̲o̲n̲t̲r̲o̲l̲



3.2.4.1  A̲d̲d̲r̲e̲s̲s̲i̲n̲g̲ ̲S̲c̲h̲e̲m̲e̲ ̲C̲o̲n̲t̲r̲o̲l̲ ̲M̲e̲n̲u̲ (ADSC)

         The menu to this section will give you the possibility
         for control at different tables like:

         -   Local/Global PLA TABLES (plain language address)

         -   Local/Global RI TABLES  (routing indicator)

         -   SIC TABLES (subject indicator code)

         -   SDL TABLES (standard distribution list)

         -   SCD TABLES (staff cell designator)

         -   AIG TABLES (address indicator group)

         -   CIRCUIT TABLES

         -   SCARS/ACCIS DISPLAY TABLES

         -   OPERATING SIGNAL TABLES



3.2.4.2  L̲o̲c̲a̲l̲ ̲P̲L̲A̲-̲T̲a̲b̲l̲e̲ ̲U̲p̲d̲a̲t̲e̲ (LPLT)



         LOCAL PLAIN LANGUAGE ADDRESS.

         LOCAL PLA-TABLE UPDATE is part of the addressing scheme
         control. 

         This section enables you to enter plain language addresses
         for local headquarters.

         In the format, you can jump forward or backward by
         moving the cursor to the desirable entries.

         After validation, if the system finds an invalid entry,
         an error message number will appear in the left hand
         margin on a level with the field in question.
         The actual field will be highlighted (reversed video).

         You must correct your mistake by valid data.

         If you need further error number explanation, proceed
         to the error messages and error handling section.



3.2.4.3  L̲o̲c̲a̲l̲ ̲R̲I̲-̲T̲a̲b̲l̲e̲ ̲U̲p̲d̲a̲t̲e̲ (LORI)



         LOCAL ROUTING INDICATOR.

         LOCAL RI-TABLE UPDATE is part of the addressing scheme
         control.

         This section enables you to:

         -   Enter routing indicators for local headquarters.

         In the format, you can jump forward or backward by
         moving the cursor to the desirable entries.

         After validation, if the system finds an invalid entry,
         an error message number will appear in the left hand
         margin on a level with the fields in question.
         The actual field will be highlighted (reversed video).

         You must correct your mistake by inserting valid data.

         If you need further error number explanation, proceed
         to the error messages and error handling section.



3.2.4.4  S̲I̲C̲-̲T̲a̲b̲l̲e̲ ̲U̲p̲d̲a̲t̲e̲ (SICT)



         SUBJECT INDICATOR CODE. 

         SIC-TABLE UPDATE is part of the addressing scheme control.

         This section enables you to enter a list of SDLs which
         distribute an incoming message.

         In the format, you can jump forward or backward by
         moving the cursor to the desirable entries.

         After validation, if the system finds an invalid entry,
         an error message number will appear in the left hand
         margin on a level with the field in question.
         The actual field will be highlighted (reversed video).

         You must correct your mistake by inserting valid data.

         If you need further error number explanation, proceed
         to the error messages and error handling section.



3.2.4.5  S̲D̲L̲-̲T̲a̲b̲l̲e̲ ̲U̲p̲d̲a̲t̲e̲ (SDLT)



         STANDARD DISTRIBUTION LIST. 

         SDL-TABLE UPDATE is part of the addressing scheme control.

         This section enables you to enter a list of staff cell
         designators.

         In the format, you can jump forward or backward by
         moving the cursor to the desirable entries.

         After validation, if the system finds an invalid entry,
         an error message number will appear in the left hand
         margin on a level with the field in question.
         The field will be highlighted (reverse video).

         You must correct your mistake by inserting valid data.

         If you need further error number explanation, proceed
         to the error messages and error handling section.



3.2.4.6  S̲C̲D̲-̲T̲a̲b̲l̲e̲ ̲U̲p̲d̲a̲t̲e̲ (SCDT)



         STAFF CELL DESIGNATOR. 

         SCD-TABLE UPDATE is part of the addressing scheme control.

         This section enables you to enter a device or terminal
         type to the specified SCD.

         In the format, you can jump forward or backward by
         moving the cursor to the desirable entries.

         After validation, if the system finds an invalid entry,
         an error message number will appear in the left hand
         margin on a level with the field in question.
         The actual field will be highlighted (reversed video).

         You must correct your mistake by inserting valid data.

         If you need further error number explanation, proceed
         to the error messages and error handling section.



3.2.4.7  A̲I̲G̲-̲T̲a̲b̲l̲e̲ ̲U̲p̲d̲a̲t̲e̲ (AIGT)



         ADDRESS INDICATOR GROUP. 

         AIG-TABLE UPDATE is part of the addressing scheme control.
         

         This section enables you to enter a group of commonly
         used addresses for outgoing messages.

         In the format, you can jump forward or backward by
         moving the cursor to the desirable entries.

         After validation, if the system finds an invalid entry,
         an error message number will appear in the left hand
         margin on a level with the field in question.
         The actual field will be highlighted (reversed video).

         You must correct your mistake by inserting valid data.

         If you need further error number explanation, proceed
         to the error messages and error handling section.



3.2.4.8  G̲l̲o̲b̲a̲l̲ ̲P̲L̲A̲-̲T̲a̲b̲l̲e̲ ̲U̲p̲d̲a̲t̲e̲ (GPLT)



         GLOBAL PLAIN LANGUAGE ADDRESS. 

         GLOBAL PLA-TABLE UPDATE is part of the addressing scheme
         control.

         This section enables you to enter plain language addresses
         of all headquaters in NATO.

         In the format, you can jump forward or backward by
         moving the cursor to the desirable entries.

         After validation, if the system finds an invalid entry,
         an error message number will appear in the left hand
         margin on a level with the field in question.
         The actual field will be highlighted (reversed video).

         You must correct your mistake by inserting valid data.

         If you need further error number explanation, proceed
         to the error messages and error handling section.



3.2.4.9  R̲I̲-̲T̲a̲b̲l̲e̲ ̲U̲p̲d̲a̲t̲e̲ (RITA)



         ROUTING INDICATOR.

         RI-TABLE UPDATE is part of the addressing scheme control.

         This section enables you to enter circuit number and
         classification to the specified RI.

         In the format, you can jump forward or backward by
         moving the cursor to the desirable entries.

         After validation, if the system finds an invalid entry,
         an error message number will appear in the left hand
         margin on a level with the field in question.
         The actual field will be highlighted (reversed video).

         You must correct your mistake by inserting valid data.

         If you need further error number explanation, proceed
         to the error messages and error handling section.



3.2.4.10 C̲i̲r̲c̲u̲i̲t̲-̲T̲a̲b̲l̲e̲ ̲U̲p̲d̲a̲t̲e̲ (CIRT)



         CIRCUIT-TABLE UPDATE is part of the addressing scheme
         control.

         This section enables you to:

         -   Enter network type

         -   Enter classification

         In the format, you can jump forward or backward by
         moving the cursor to the desirable entries.

         After validation, if the system finds an invalid entry,
         an error message number will appear in the left hand
         margin on a level with the field in question.
         The actual field will be highlighted (reversed video).

         You must correct your mistake by inserting valid data.

         If you need further error number explanation, proceed
         to the error messages and error handling section.



3.2.4.11 S̲C̲A̲R̲S̲/̲A̲C̲C̲I̲S̲ ̲D̲i̲s̲p̲l̲a̲y̲-̲T̲a̲b̲l̲e̲ ̲U̲p̲d̲a̲t̲e̲ (SCCT)



         SCARS/ACCIS DISPLAY-TABLE UPDATE is part of the addressing
         scheme control.

         This section enables you to identify display ID's.

         In the format, you can jump forward or backward by
         moving the cursor to the desirable entries.

         After validation, if the system finds an invalid entry,
         an error message number will appear in the left hand
         margin on a level with the field in question.
         The actual field will be highlighted (reversed video).

         You must correct your mistake by inserting valid data.

         If you need further error number explanation, proceed
         to the error messages and error handling section.



3.2.4.12 O̲p̲e̲r̲a̲t̲i̲n̲g̲ ̲S̲i̲g̲n̲a̲l̲-̲T̲a̲b̲l̲e̲ ̲U̲p̲d̲a̲t̲e̲ (OPST)



         OPERATING SIGNAL-TABLE UPDATE is part of the addressing
         scheme control.

         This section enables you to enter a message handling
         text to the specified MHI code.

         In the format, you can jump forward or backward by
         moving the cursor to the desirable entries.

         After validation, if the system finds an invalid entry,
         an error message number will appear in the left hand
         margin on a level with the field in question.
         The actual field will be highlighted (reversed video).

         You must correct your mistake by inserting valid data.

         If you need further error number explanation, proceed
         to the error messages and error handling section.



3.2.4.13   R̲e̲o̲r̲g̲a̲n̲i̲z̲e̲ ̲A̲l̲l̲ ̲T̲a̲b̲l̲e̲s̲ (REOR)



         REORGANIZE ALL TABLES is part of the addressing scheme
         control. 

         The system perform table updating with an overflow
         mechanism to prevent reorganization of the tables for
         every updating. By use of table status print (TSTP)
         you can get the actual number of table entries in the
         overflow area.

         At the moment when the number of table entries are
         too large, the system will automatically inform you
         to reorganize.

         If you need error/report explanation, proceed to the
         error messages and error handling section or reports
         and report handling section respectively.



3.2.4.14   A̲b̲a̲n̲d̲o̲n̲ ̲R̲e̲o̲r̲g̲a̲n̲i̲z̲a̲t̲i̲o̲n̲ (ABRO)



         ABANDON REORGANISATION is part of the addressing scheme
         control.

         If you have started the command reorganize all tables
         (REOR), you can stop the current reorganization by
         using the command ABRO (abandon reorganization). The
         command ABRO will cause to stop the reorganization
         and the tables will stay in the same state as before
         the request to reorganize was sent.



3.2.5    U̲s̲e̲r̲ ̲P̲r̲o̲f̲i̲l̲e̲ ̲U̲p̲d̲a̲t̲e̲ (UPUP)



         USER PROFILE UPDATE is part of the system control.

         This section enables you to specify the users:

         -   Identification.

         -   Capability.

         -   Maximum classification plus special handling categories.

         You can enter/change the users password and set the
         time period for which it is valid.

         You cannot change the data in a user profile if the
         actual user is s̲i̲g̲n̲e̲d̲ ̲o̲n̲.
.
         In the format, you can jump forward or backward by
         moving the cursor to the desirable entries.

         After validation, if the system finds an invalid entry,
         an error message number will appear in the left hand
         margin on a level with the field in question.
         The actual field will be highlighted (reversed video).

         You must correct your mistake by inserting valid data.

         If you need further error number explanation, proceed
         to the error messages and error handling section.



3.2.6    Q̲u̲e̲u̲e̲ ̲C̲o̲n̲t̲r̲o̲l̲



3.2.6.1  Q̲u̲e̲u̲e̲ ̲C̲o̲n̲t̲r̲o̲l̲ ̲M̲e̲n̲u̲ (QUEC)

         The menu to this section will give you the possibility
         for control of queues belonging to:

         -   CIRCUITS

         -   TERMINALS

         -   DEVICES



3.2.6.2  C̲i̲r̲c̲u̲i̲t̲ ̲Q̲u̲e̲u̲e̲ ̲B̲l̲o̲c̲k̲e̲d̲ (BLCQ)



         CIRCUIT QUEUE BLOCKED is part of the queue control.

         If you have selected BLCQ, no more messages will be
         queued for the specified circuit.

         The entered circuit No. must be in the range 1-27.

         If you need error/report explanation, proceed to the
         error messages and error handling section or reports
         and report handling section respectively.




3.2.6.3  C̲i̲r̲c̲u̲i̲t̲ ̲Q̲u̲e̲u̲e̲ ̲U̲n̲b̲l̲o̲c̲k̲e̲d̲ (UBCQ)



         CIRCUIT QUEUE UNBLOCK is part of the queue control.

         If you have selected UBCQ, no more messages will be
         queued for the specified circuit.

         The entered circuit No. must be in the range 1-27.

         If you need error/report explanation, proceed to the
         error messages and error handling section or reports
         and report handling section respectively.



3.2.6.4  C̲i̲r̲c̲u̲i̲t̲ ̲Q̲u̲e̲u̲e̲ ̲C̲a̲n̲c̲e̲l̲l̲a̲t̲i̲o̲n̲ (CACQ)



         CIRCUIT QUEUE CANCELLATION is part of the queue control.

         This section enables you to specify precedences for
         messages to be cancelled from the circuit queue.

         In the format, you can jump forward or backward by
         moving the cursor to the desirable entries.

         After validation, if the system finds an invalid entry,
         an error message number will appear in the left hand
         margin on a level with the field in question.
         The actual field will be highlighted (reversed video).

         You must correct your mistake by inserting valid data.

         If you need further error number explanation, proceed
         to the error messages and error handling section.


3.2.6.5  T̲e̲r̲m̲i̲n̲a̲l̲ ̲Q̲u̲e̲u̲e̲ ̲B̲l̲o̲c̲k̲e̲d̲ (BLTQ)



         TERMINAL QUEUE BLOCKED is part of the queue control.

         If you have selected BLTQ, no more messages can be
         sent to the release-, response- and receive queue for
         the specified terminal.

         If you need error/report explanation, proceed to the
         error messages and error handling section or reports
         and report handling section respectively.



3.2.6.6  T̲e̲r̲m̲i̲n̲a̲l̲ ̲Q̲u̲e̲u̲e̲ ̲U̲n̲b̲l̲o̲c̲k̲e̲d̲ (UBTQ)



         TERMINAL QUEUE UNBLOCKED is part of the queue control.

         If you have selected UBTQ, messages can be sent to
         the release-, response- and receive queue for the specified
         terminal.

         If you need error/report explanation, proceed to the
         error messages and error handling section or reports
         and report handling section respectively.



3.2.6.7  T̲e̲r̲m̲i̲n̲a̲l̲ ̲Q̲u̲e̲u̲e̲ ̲C̲a̲n̲c̲e̲l̲l̲a̲t̲i̲o̲n̲ (CATQ)



         TERMINAL QUEUE CANCELLATION is part of the queue control.

         This section enables you to specify precedences for
         messages to be cancelled in different terminal queues,
         and cancel messages under preparation, if any.

         In the format, you can jump forward or backward by
         moving the cursor to the desirable entries.

         After validation, if the system finds an invalid entry,
         an error message number will appear in the left hand
         margin on a level with the field in question.
         The actual field will be highlighted (reversed video).

         You must correct your mistake by inserting valid data.

         If you need further error number explanation, proceed
         to the error messages and error handling section.


3.2.6.8  D̲e̲v̲i̲c̲e̲ ̲Q̲u̲e̲u̲e̲ ̲B̲l̲o̲c̲k̲e̲d̲ (BLDQ)



         DEVICE QUEUE BLOCKED is part of the queue control.

         If you have selected BLDQ, no more messages can be
         queued for the specified output device. You cannot
         block dedicated output devices.

         If you need error/report explanation, proceed to the
         error messages and error handling section or reports
         and report handling section respectively.



3.2.6.9  D̲e̲v̲i̲c̲e̲ ̲Q̲u̲e̲u̲e̲ ̲U̲n̲b̲l̲o̲c̲k̲e̲d̲ (UBDQ)



         DEVICE QUEUE UNBLOCKED is part of the queue control.

         If you have selected UBDQ, messages can be queued for
         the specified output device.

         If you need error/report explanation, proceed to the
         error messages and error handling section or reports
         and report handling section respectively.



3.2.6.10 D̲e̲v̲i̲c̲e̲ ̲Q̲u̲e̲u̲e̲ ̲C̲a̲n̲c̲e̲l̲l̲a̲t̲i̲o̲n̲ (CADQ)



         DEVICE QUEUE CANCELLATION is part of the queue control.

         This section enables you to specify precedences for
         messages to be cancelled from the device queue.

         In the format, you can jump forward or backward by
         moving the cursor to the desirable entries.

         After validation, if the system finds an invalid entry,
         an error message number will appear in the left hand
         margin on a level with the field in question.
         The actual field will be highlighted (reversed video).

         You must correct your mistake by inserting valid data.

         If you need further error number explanation, proceed
         to the error messages and error handling section.


3.2.7        S̲u̲p̲e̲r̲v̲i̲s̲o̲r̲ ̲P̲r̲i̲n̲t̲ ̲C̲o̲n̲t̲r̲o̲l̲ (SUPC)



         SUPERVISOR PRINT CONTROL is part of the system control.

         This section enables you to define which MSPs you will
         use for report-, supervisor-, log-, and statistic print.

         In the format, you can jump forward or backward by
         moving the cursor to the desirable entries.

         After validation, if the system finds an invalid entry,
         an error message number will appear in the left hand
         margin on a level with the field in question.
         The actual field will be highlighted (reversed video).

         You must correct your mistake by inserting valid data.

         If you need further error number explanation, proceed
         to the error messages and error handling section.


3.2.8    D̲i̲s̲c̲ ̲C̲o̲n̲t̲r̲o̲l̲



3.2.8.1  D̲i̲s̲c̲ ̲C̲o̲n̲t̲r̲o̲l̲ ̲M̲e̲n̲u̲ (DISC)



         The menu to this section will give you the possibility
         for control of data in short term storage and long
         term storage.



3.2.8.2   O̲f̲f̲-̲L̲o̲a̲d̲ ̲D̲a̲t̲a̲ (OFLD)



         OFF-LOAD DATA is part of the disc control. 

         OFLD, "TIMESTAMP", VOL-ID

         If you have selected OFLD, the system will off-load
         data from short term storage to long term storage for
         the specified volume ID until the specified time.

         The Time Stamp must consist of 14 characters
         Date(2) - Hour(2) - Minute(2) - Zone(1) - Space(1)
         -
         Month(3) - Space(1) - Year(2).

         For instance: 192135Z FEB 82

         If you need error/report explanation, proceed to the
         error messages and error handling section or reports
         and report handling section respectively.


3.2.8.3   A̲b̲a̲n̲d̲o̲n̲ ̲O̲f̲f̲-̲L̲o̲a̲d̲ (ABOL)



         ABANDON OFF-LOAD is part of the disc control.

         If you have started the command off load data, you
         can stop the process by using the command ABOL (abandon
         off load).

         The command ABOL will cause to stop the off load process
         and data will stay in the same state as before the
         request to off-load data was sent.

         If you need error/report explanation, proceed to the
         error messages and error handling section or reports
         and report handling section respectively.



3.2.8.4   C̲o̲p̲y̲ ̲S̲y̲s̲t̲e̲m̲ ̲P̲a̲r̲a̲m̲e̲t̲e̲r̲ ̲F̲i̲l̲e̲ (COPY)



         COPY SYSTEM PARAMETER FILE is part of the disc control.

         If you have selected COPY the system will make a copy
         of the system parameter file to the currently mounted
         off line disc.

         If you need error/report explanation, proceed to the
         error messages and error handling section or reports
         and report handling section respectively.



3.2.8.5   O̲f̲f̲-̲L̲i̲n̲e̲ ̲R̲e̲t̲r̲i̲e̲v̲a̲l̲ ̲O̲f̲f̲ (OROF)



         OFF LINE RETRIEVAL OFF is part of the disc control.

         If you have selected OROF, the system will not allow
         operators to retrieve data from the off-line disc.

         If you need error/report explanation, proceed to the
         error messages and error handling section or reports
         and report handling section respectively.



3.2.8.6   O̲f̲f̲-̲L̲i̲n̲e̲ ̲R̲e̲t̲r̲i̲e̲v̲a̲l̲ ̲O̲n̲ (ORON)



         OFF LINE RETRIEVAL ON is part of the disc control.

         If you have selected ORON, the system will allow operators
         to retrieve data from the off-line disc.

         If you need error/report explanation, proceed to the
         error messages and error handling section or reports
         and report handling section respectively.



3.2.8.7   O̲f̲f̲-̲L̲i̲n̲e̲ ̲R̲e̲t̲r̲i̲e̲v̲a̲l̲ ̲S̲u̲s̲p̲e̲n̲d̲ (ORSU)



         OFF LINE RETRIEVAL SUSPEND is part of the disc control.

         If you have selected ORSU, the system will not allow
         operators to retrieve data from the off-line disc,
         but requests will be queued in the system.

         The requests will not be performed before you have
         entered the command ORON.

         If you need error/report explanation, proceed to the
         error messages and error handling section or reports
         and report handling section respectively.



3.2.8.8   L̲i̲s̲t̲ ̲V̲o̲l̲u̲m̲e̲s̲ ̲C̲u̲r̲r̲e̲n̲t̲l̲y̲ ̲I̲n̲ ̲U̲s̲e̲ (VOLI)



         LIST VOLUMES CURRENTLY IN USE is part of the disc control.

         If you have selected VOLI, the system will print out
         a list of all volumes currently in use by the system
         for long time storage.

         For every volume, you will get the following information:

       VOLUME ID  OLDEST TOC  YOUNGEST TOC  OLDEST DTG  YOUNGEST
 DTG
        ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲   ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲   ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲   ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲   ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

         TOC: Time of Occurence
         DTG: Date Time Group

         This information will be sent to your SUPERVISOR PRINTER.

         If you need error/report explanation, proceed to the
         error messages and error handling section or reports
         and report handling section respectively.



3.2.8.9   R̲e̲f̲u̲s̲e̲ ̲M̲o̲u̲n̲t̲ ̲o̲f̲ ̲V̲o̲l̲u̲m̲e̲ (REMO)



         REFUSE MOUNT OF VOLUME is part of the disc control.

         If you have selected REMO, the system will not allow
         request about mounting of the specified volume.

         If you need error/report explanation, proceed to the
         error messages and error handling section or reports
         and report handling section respectively.



3.2.8.10  M̲o̲u̲n̲t̲ ̲V̲o̲l̲u̲m̲e̲ (VOMO)



         MOUNT VOLUME is part of the disc control.

         If you have selected VOMO, the system will allow request
         about mounting of the specified volume.

         If you need error/report explanation, proceed to the
         error messages and error handling section or reports
         and report handling section respectively.



3.2.9    C̲o̲m̲m̲a̲n̲d̲ ̲C̲o̲n̲t̲r̲o̲l̲ (CMDC)



         COMMAND CONTROL is part of the system control.

         This section enables you to protect supervisor commands
         from misuse.

         You can enter or change an extra code, PEC, permissive
         entry code, to the command and define a restrictive
         warning text.

         In the format, you can jump forward or backward by
         moving the cursor to the desirable entries.

         After validation, if the system finds an invalid entry,
         an error message number will appear in the left hand
         margin on a level with the field in question.
         The actual field will be highlighted (reversed video).

         You must correct your mistake by inserting valid data.

         If you need further error number explanation proceed
         to the error messages and error handling section.



3.2.10   S̲e̲c̲u̲r̲i̲t̲y̲ ̲C̲o̲n̲t̲r̲o̲l̲ (SECC)



         SECURITY CONTROL is part of the system control.

         This section enables you to define the degree of security
         procedures for reception of messages.

         Users can be interrogated by CAMPS before they are
         allowed to receive a message. You can define the warning
         text which the users can receive before they are allowed
         to receive a message. The user must clear himself by
         entering a warning code which you also define here.

         In the format, you can jump forward or backward by
         moving the cursor to the desirable entries.

         After validation, if the system finds an invalid entry,
         an error message number will appear in the left hand
         margin on a level with the field in question.
         The actual field will be highlighted (reversed video).

         You must correct your mistake by inserting valid data.

         If you need further error number explanation, proceed
         to the error messages and error handling section.




3.2.11   G̲l̲o̲b̲a̲l̲ ̲N̲o̲.̲ ̲S̲e̲r̲i̲e̲s̲ ̲C̲o̲n̲t̲r̲o̲l̲



3.2.11.1 G̲l̲o̲b̲a̲l̲ ̲N̲o̲.̲ ̲S̲e̲r̲i̲e̲s̲ ̲C̲o̲n̲t̲r̲o̲l̲ ̲M̲e̲n̲u̲ (GNSC)

         The menu to this section will give you the possibility
         for control of different No. series belonging to:

         -   SYSTEM

         -   CHANNELS

         -   TRANSACTION IDs



3.2.11.2   S̲y̲s̲t̲e̲m̲ ̲N̲o̲.̲ ̲S̲e̲r̲i̲e̲s̲ ̲C̲o̲n̲t̲r̲o̲l̲ (NOSC)



         SYSTEM NO. SERIES CONTROL is part of the global no.
         series control. 

         This section enables you to reset the sequence number
         of different type of messages handled by the system.

         In the format, you can jump forward or backward by
         moving the cursor to the desirable entries.

         After validation, if the system finds an invalid entry,
         an error message number will appear in the left hand
         margin on a level with the field in question.
         The actual field will be highlighted (reversed video).

         You must correct your mistake by inserting valid data.

         If you need further error number explanation proceed
         to the error messages and error handling section.





3.2.11.3   C̲h̲a̲n̲n̲e̲l̲ ̲N̲o̲.̲ ̲S̲e̲r̲i̲e̲s̲ ̲C̲o̲n̲t̲r̲o̲l̲ (NOCC)



         CHANNEL NO. SERIES CONTROL is part of the global no.
         series control. 

         This section enables you to reset the sequence number
         of messages sent over a specific channel.

         In the format, you can jump forward or backward by
         moving the cursor to the desirable entries.

         After validation, if the system finds an invalid entry,
         an error message number will appear in the left hand
         margin on a level with the field in question.
         The actual field will be highlighted (reversed video).

         You must correct your mistake by inserting valid data.

         If you need further error number explanation proceed
         to the error messages and error handling section.





3.2.11.4 T̲r̲a̲n̲s̲a̲c̲t̲i̲o̲n̲ ̲N̲o̲.̲ ̲S̲e̲r̲i̲e̲s̲ ̲R̲e̲s̲e̲t̲ (NOTR)



         TRANSACTION NO. SERIES RESET is part of the global
         no. series control.

         If you have selected NOTR, the system will reset the
         3 digit sequence number of messages used as part of
         the transaction id to the specified terminal or device.

         If you need error/report explanation, proceed to the
         error messages and error handling section or reports
         and report handling section respectively.







              r̲e̲s̲t̲e̲n̲ …01…herfra er sat i 2679A






         PLA         AB SMEJSEN

         PLAREF      1317

         RI              CLASS   CIRCUIT

         VETKFR           SS       05






         PLA         AB GJINDER

         PLAREF      1523

         RI              CLASS   CIRCUIT

         PJRECT           SS       05


PLA ̲REF TABLE    FROM:0010          TO:0050   ENDED
TERMINATED:   SUCCESFULLY






         DESIGNATOR SPU                 TYPE SUPV

         MAXIMUM CLASSIFICATION TT

         SPECIAL HANDLING CATEGORIES    LL  DD  YY  PP

         CAPABILITIES:
             SUPERVISOR     Y     MSO             Y     MDCO
                      Y
             PREPARATION    N     RECEPTION       N     RELEASE
                   N

         PORT ID    01      ASSOCIATED PRINTER MSJ

         USERS
          VPS

         SCDS
          SPU


TERMINAL PROFILE PRINT ENDED
TERMINATED:   SUCCESFULLY