OctetView
0x00000…00100 (0, 0, 0) Sector 03314130333331 ┆ 1A0331A ┆
0x00100…00200 (0, 0, 1) Sector 00000000000000 ┆ ┆
0x00200…00300 (0, 0, 2) Sector ff00fefeffffff ┆ ~~ ┆
0x00300…00306 (0, 0, 3) WangDocument {d00=0x38, d01=0x42, d02=0x41, ptr=(25,0, 8), d05=0x00}
0x00306…0030c WangDocument {d00=0x38, d01=0x43, d02=0x41, ptr=(44,0, 8), d05=0x00}
0x0030c…00320 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ┆ ┆
0x00320…00340 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ┆ ┆
[…0x5…]
0x003e0…00400 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0c ┆ ┆
0x00400…00500 (0, 0, 4) Sector 00000000000000 ┆ ┆
0x00500…00600 (0, 0, 5) Sector 03314130333331 ┆ 1A0331A ┆
0x00600…00700 (0, 0, 6) Sector 421c402600415b ┆B @& A[' J X% % PO P ; 8CA ? C f x f V Wz O 8 :P8 P;> 7 3843A f JH < {C < { ; 2 ` f! b bD , K 9 : 8 > t xyy 3842A3843A ;6;7:8;4'1'> ┆
0x00700…00800 (0, 0, 7) Sector 00000000000000 ┆ ┆
[…0x8…]
0x01000…01100 (1, 0, 0) WangDocumentBody
[…0x6…]
0x01700…01800 (1, 0, 7) Sector 00000000000000 ┆ ┆
0x01800…01900 (1, 0, 8) WangDocumentBody
[…0x6…]
0x01f00…02000 (1, 0, 15) Sector 00000000000000 ┆ ┆
0x02000…02100 (2, 0, 0) WangDocumentBody
[…0x177…]
0x19800…19900 (25, 0, 8) WangDocumentHead {hdr=WangSectHead {next=(25,0, 9), len=0xff, h3=41384241}, f00=»3842A «, f01=»CPS/AUX/073 (SITE 12) «, f02=»rt «, f03=»SPN «, f04=»CPS INST.PROC.SITE «, f05=28-06-83 11:24, f06=» 3 «, f07=»58 «, f08=» 3037 «, f09=12-07-83 10:32, f10=» «, f11=»01 «, f12=» 15 «, f13=12-07-83 10:41, f14=12-07-83 10:50, f15=»0331A «, f16=» 80 «, f17=» 4 «, f18=»27 «, f19=» 1236 «, f20=» 3464 «, f21=» «, f22=» «, f99=800065000910462710110170aaca15050000000000000138038701df}
0x19900…19a00 (25, 0, 9) WangDocumentBody
[…0x12e…]
0x2c800…2c900 (44, 0, 8) WangDocumentHead {hdr=WangSectHead {next=(44,0, 9), len=0xff, h3=41384341}, f00=»3843A «, f01=»CPS/AUX/073 (SITE 12) «, f02=»rt «, f03=»SPN «, f04=»CPS.INST.PROC.SITE «, f05=28-06-83 11:25, f06=» «, f07=»57 «, f08=» 484 «, f09=12-07-83 10:33, f10=» «, f11=»01 «, f12=» 87 «, f13=12-07-83 10:42, f14=12-07-83 10:50, f15=»0331A «, f16=» 62 «, f17=» 1 «, f18=»00 «, f19=» 988 «, f20=» 625 «, f21=» «, f22=» «, f99=720099000110462710110170aaca15050000000000000038033701df}
0x2c900…2ca00 (44, 0, 9) WangDocumentBody
[…0x6…]
0x2d000…2d100 (45, 0, 0) WangDocumentHead {hdr=WangSectHead {next=(45,0, 1), len=0xff, h3=41384341}, f00=»3843A «, f01=»CPS/AUX/073 (SITE 12) «, f02=»rt «, f03=»SPN «, f04=»CPS.INST.PROC.SITE «, f05=28-06-83 11:25, f06=» «, f07=»57 «, f08=» 484 «, f09=29-06-83 14:04, f10=» «, f11=»00 «, f12=» 6 «, f13=29-06-83 12:38, f14=08-07-83 14:33, f15=»0331A «, f16=» 62 «, f17=» «, f18=»57 «, f19=» 1000 «, f20=» 490 «, f21=» «, f22=» «, f99=020037000110462710110170aaca15050000000000000038033701df}
0x2d100…2d200 (45, 0, 1) Sector 2d023e00384341 ┆- > 8CA - - - , , , + + + + * * * ) ) ) ) ) ( ( ( ' ' ' & & & & % % % $ $ $ # # # " " ! ! ! mmentarer: STATISTIK AKTIVITET DATO TID ANV.TID ANSLAG Oprettet / / : : S: S : : S: S S┆
0x2d200…2d300 (45, 0, 2) Sector 2d03b200384341 ┆- 2 8CA 1 3843A/ktd CPS/AUX/073 SPN/830630 # CAMPS INSTALLATION PROCEDURES SITE 12 CAMPS > I!e=6 !Z="(=e*$<kas#r 9x2"<! <6 M8)I:^=~ B#.!#<6 ! <6 M&&:!<~ J#.:!<2.=M2┆
0x2d300…2d400 (45, 0, 3) Sector 2d04ff00384341 ┆- 8CA 1 5.9 POWER UP AND CHECK OUT Before powering up, verify that all switches on all equipment are in position off or O. 5.9.1 Groundings a) Measure with an Ohm-meter that no short┆
0x2d400…2d500 (45, 0, 4) Sector 2d05ff00384341 ┆- 8CA circuit exists between the safety group (cabinets) and the lines of circuit no. 1 through 9 and 1a through 3a. b) Remount the lids of the power line filters by the 30 screws. c) Measure with an Ohm-meter if the "Equipment Frame Ground" (cabinet┆
0x2d500…2d600 (45, 0, 5) Sector 2d06ff00384341 ┆- 8CAs) is isolated from the "Signal Ground" (5V return). The "Signal Ground" (GND) is found on the CCA-panel, refer to Figure 5.9.1. d) Start the powering up in the below sequence, starting at the CAMPS power distribution board (PDB): 5.9.2 CAMP┆
0x2d600…2d700 (45, 0, 6) Sector 2d07ab00384341 ┆- + 8CAS PDB TURN ON: Main circuit breaker TURN ON: Miniature circuit breakers CHECKOUT: No fuses in the CAMPS PDB blown due to short circuit in the installation. &<6 ! "$<!#<6 ! <6 {M)(sC I! <6 ! "(= <q#p!"<6 !#<6 ! "$<!&<6$`i6 {M)(sM &M7 ┆
0x2d700…2d800 (45, 0, 7) Sector 2c08a000384341 ┆, 8CA 1 Figure 5.9.1 Front Layout for CCA L<M% :8=F 28=I!#<:"<>R<2> I E*#<& "< DM L<M% :#<F 2#<> I:g= Ro2M/2 Rl2> IC13!?=4~~ B|2> I:A=!┆
0x2d800…2d900 (45, 0, 8) Sector 00000000000000 ┆ ┆
[…0x1f7…]