…02…CPS/TCM/027

…02…LU/830719…02……02…#
CAMPS POWER LINE FILTER
…02……02…CAMPS














                 CAMPS POWER LINE FILTER


                 CPS/TCM/027
                 CDRL Documentation No. 03
                 Line Item No. 9.3












                 Bjarne Berthold/Leif Uldam




                 Kurt Nybroe-Nielsen








                 SHAPE (3), NCS (1), GJ, KNN, BHB, QA,
                 Conf. Mgmt., PMS, KM, LT, LU, GQAR















                     …0e……0e…     ILS Manager     830719…0f……0f…


         …0e…1



         830719…0f…           Conf. Mgmt.     830719




    3875A/jaa      …02…CPS/TCM/027

                           …02…LU/830719…02…   ii
CAMPS POWER LINE FILTER      
                                …02……02…CAMPS












               her inds`ttes "Kiss of Life"




…0f…    3875A/jaa      …02…CPS/TCM/027

                          …02…LU/830719…02…   iii
CAMPS POWER LINE FILTER      
                             …02……02… CAMPS…0e…












        830719                All      First Issue of Document




…0f…    3875A/jaa      …02…CPS/TCM/027

                          …02…LU/830719…02…   iv
CAMPS POWER LINE FILTER      
                              …02……02…CAMPS…0e…









                                      T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲




     TITLE PAGE  ....................................  
      i

     FIRST AID FOR ELECTRICAL SHOCK .................  
     ii

     REVISION RECORD ................................  iii

     TABLE OF CONTENTS ..............................  
     iv

     1 SCOPE ........................................  
        1

     2 MAINTENANCE ..................................  
        1

     3 CONNECTION WITH SURROUNDINGS .................  
        1

     4 APPLICABLE DOCUMENTS .........................  
      1

     5 CAPTOR POWER LINE FILTER DOCUMENTATION .......  
        2
       5.1 SPECIFICATIONS ...........................  
            3
       5.2 BLOCKED SCHEMATIC ........................  
            5
       5.3 PARTS LIST ...............................  
            6
       5.4 ASSEMBLY DRAWING .........................  
            7



                         1  S̲C̲O̲P̲E̲

         The CAPTOR Power Line Filter (PLF) Technical Manual
         is an OEM Manual grouped under 'Peripheral Equipment
         Manuals' in the CAMPS Documentation Tree.



\…01…2  M̲A̲I̲N̲T̲E̲N̲A̲N̲C̲E̲

         The PLF Box has been soldered together and therefore
         it cannot be disassembled.

         In case of malfunction, the PLF Box shall be replaced.



             3  C̲O̲N̲N̲E̲C̲T̲I̲O̲N̲ ̲W̲I̲T̲H̲ ̲S̲U̲R̲R̲O̲U̲N̲D̲I̲N̲G̲S̲

         How the PLF is connected with CAMPS is shown in the
         CAMPS Hardware Assembly Breakdown CPS/SDS/017.



                 4   A̲P̲P̲L̲I̲C̲A̲B̲L̲E̲ ̲D̲O̲C̲U̲M̲E̲N̲T̲S̲

         Hardware Assembly Breakdown
         CPS/SDS/017



        5  C̲A̲P̲T̲O̲R̲ ̲P̲O̲W̲E̲R̲ ̲L̲I̲N̲E̲ ̲F̲I̲L̲T̲E̲R̲ ̲D̲O̲C̲U̲M̲E̲N̲T̲A̲T̲I̲O̲N̲

         This manual includes, besides the Specifications, also
         the Blocked Schematic, Assembly Drawing and Parts List.

         (The CAPTOR Documentation to the Power Line Filter
         is enclosed in the following)


5.1      C̲A̲P̲T̲O̲R̲ ̲P̲O̲W̲E̲R̲ ̲L̲I̲N̲E̲ ̲F̲I̲L̲T̲E̲R̲ ̲S̲P̲E̲C̲I̲F̲I̲C̲A̲T̲I̲O̲N̲S̲

         Operating voltage:          220 VAC or 240 VAC
         Voltage tolerances:         +10%/-15%

         Voltage Rating:             240 VAC line to case
                                     415 VAC line to line

         Operating Frequency
         (Power):                    50 Hz
         Frequency tolerances:       + 10%/-10%

         Current Rating:             10 Amps RMS continuous
                                     for each of the three paired
                                     sections.

         Dielectric Withstanding
         Voltage:                    1200 VDC line to case
                                     1500 VDC line to line (1
                                     min. at 23…0e…o…0f… C)

         Voltage Drop:               1% maximum full load (10
                                     Amps RMS) and unity power
                                     factor

         Temperature Rise            25…0e…o…0f… C maximum at full load

         Insertion Loss              See Figure 5.1-1. in accordance
                                     with MIL-STD-220A, full
                                     load extended to 40KHz.

         Max oper. altitude          2000 m above sea level
















































               FIGURE 5.1-1 INSERTION LOSS