                     FE/amn     1982-11-30

to:  diablo systems ltd.
fm:  christian rovsing a/s
     flemming enevoldsen

our ref: sys/tlx/087

subject: request for quotation for supply of 113 letter quality
 printers, plus optional expansion to 267 units 1 or 2 line printers
 and one high speed non-impact printer.


you are hereby invited to submit a quotation for the supply
 of the above equipment in accordance with the specifications
 and conditions stated below.

1 general technical requirements
--------------------------------

1.1 High speed non-impact printer
---------------------------------
the high speed printer must print a minimum of 20 pages (8 1/2
 x 11 inches) per minute and must be able to interface and spool
 data directly with an electronic mail system. The following
 are also required:

1) Horizontal and vertical resolution of not less than 140 dots
 per inch.

2) printing  of the ascii 95-character subset (upper and lower
 case) as specified in FIPS PUB 15.

3) mixing of multiple fonts within the same output page. 

4) a minimum of 8 fonts.

5) merging of forms with data (overlay data) to create a single
 document.

6) accessing of stored charts, logos, signatures, and documents
 for printing.

1.2 Line printer
----------------
a minimum aggregate print speed of 900 lines per minute while
 printing at least 132 characters per line using the ascii 95-character
 subset as specified in FIPS pub 15, section 1, must be provided
 with no more than two printers. the following  minimum characteristics
 are also required:

1)  ten characters per horizontal inch
2)  six and eight lines per vertical inch, selectable
3)  adjustable pin feed tractors for pin feed fanfold paper
 paper 
    om widths of four inches to 14-7/8 inches.
4)  single- and double-space printing, multiple line skip, page
    ejection or equivalent top-of-form, selectable under both
    program and operator control.
5)  print an original and five legible copies
6)  provide error detection and notification and cease operation
    for the following conditions:

  a)   out of paper
  b)   ribbon malfunction

1.3 letter quality printers
------------------------
the following are required:
1)     printing.

  a)   a minimum speed of 35 cps
  b)   the 95 character subset as specified in fips pub
       15, section 1.
  c)   use of the control characters designated by the
       128 character set specified in fips pub 1.
  d)   a minimum of eighty (80) characters per line on
       continuous form paper.
  e)   single and double spacing under program control
  f)   lines of both 10 and 12 cpi
  g)   print six and eight lines per inch
  h)   interchangeable character sets including the fips
       pub 32, ocr-a size 1.
  i)   one original plus five legible copies from carbon
       interleaved paper.
  j)   program controlled forms spacing without using
       carriage control tapes.
  k)   interchangeable tractor feeding and manual single
       sheet feeding
  l)   print descenders
  m)   interface directly with the system

2)     keyboard

  a)   layout conforming with ansi standard x4.14-1971
  b)   generate the 128 character set specified in fips
       pub 1
  c)   repeat function for all keys

3)     meet the tempest requirements of NACSIM 5100a.

2. power input
--------------
the equipment must be able to operate with a power source
 of 120/208 volts plus or munus 10 per cent, 60 hz plus
 or minus 1 per cent, three-phase, four wire system power
 input harminic distortion requirement must be less than
 5 per cent


3 air conditioning
------------------
the equipment must be able to operate within a temperature
 range of 70 degrees f, plus or minus 20 degrees f. and
 a relative humidity between 35 per cent and 95 per cent.

4 reserved
----------

5 interface
-----------
the interface requirements to the host must be specified.

6 logistics
-----------

6.1 documentation
-----------------
6.1.1 

the supplier will be requested to submit documentation
 to component level, covering only the equipment supplied.

6.1.2 

the parts list to component level must include true manufacturer's
 part numbers.

6.1.3 

the documentation standard and quality shall enable reproduction
 and the supplier will be requested to grant permission
 to reproduce for the purpose of the this program.

6.1.4 

the documentation shall include information suitable
 for the user, for maintenance at subassembly level, and
 for maintenance at component level at depot.

6.1.5 

all documentation shall be subject to review and approval
 by or before delivery.

6.2 training
------------
6.2.1 

self-study training package or other training documentation
 must be supplied as part of the contract.

6.3 serviceability
------------------
6.3.1 it shall be easy to diagnose and fault-find to
 module level. fault shall be identifiable to a single
 module.

6.3.2 

a thorough and easily understandable checking and calibration
 procedure must be supplied with the equipment

6.3.3 

all necessary special tools and special test instruments
 should be listed and unit prices quoted.

6.3.4 

a recommended spare parts list must be submitted and
 a not-to-exceed cost of a 90 days spare stock quoted.

6.3.5 

meantime between failures (mtbf.), meantime to repair
 (mttr) as well as down-time must be specified in quotation.

6.3.6 

the rspl shall be submitted for site level (module exchange)
 and depot level (component repair) and mtbf must be specified
 for all subassemblies and components.

6.3.7 

the manufacturers configuration management procedures
 shall 
be submitted.

6.3.8 

field change notices must be supplied with necessary
 parts 
and with documentation change notices as long as the
 equipment exists in the manufacturers product line.

7. general conditions
7.1 delivery schedule
---------------------
7.1.1 high speed non-impact printer 

2 months after contract award (expected contract data,
 july 1983)

7.1.2 line printers

2 months after contract award (expected contract date,
 july 1983)

7.1.3 letter quality printers

increment 1
2 months after contract award (expected contract date,
 july 1983) 10 units
then at a rate of 30 per units per month (to a maximum
 of 113)

Increment 2 (optional)
15 months after contract award (expected contract date,
 july 1983) 14 units

increment 3 (optional)
13 months after contract award (expected contract date,
 july 1983) 20 units
then at a rate of 30 units per month

options (extra)
---------------
a quote for up to 50 extra letter qualtiy printers is
 also requested. please provide turn around time for factory
 repair.

7.2 terms of delivery: 

delivery shall be made cif cr's facility in ballerup,
 copenhagen.

delivery charges should be quoted separately

7.3 origin

bidder shall warrant the origin country of the equipment

7.4 packaging

packaging shall be for air, sea, and land trasportation
 to best commercial practice.

container which can be used for re-export are required,
 bidder is asked to specify his packaging method.

7.5 warranty

except as otherwise provided in this clause, the bidder
 warrants that all items to be delivered shall be fit
 and sufficient for the purpose intended, as stated in
 the specifications, new, merchantable, of good material
 and workmanship free from defect, and conforming to the
 specifications. the warranty shall remain in effect for
 a period of twelve (12) months after cr's acceptance

7.6 acceptance

acceptance of deliveries will be given upon incoming
 inspection at cr's facility

7.7 supply warranty

bidder are requested to warrant the supply of similar
 units and spares for a period of 10 years

7.8 quality assurance

bidder are requested to accept source inspection by national
 qa authorities in accordance with mil-i-45208a.

7.9 terms of payment

bidder are requested to accept and base their quotation
 on payment 120 days from delivery to cr's facility.

7.10 type of quotation

quotations should be firm fixed prices valid for 270
 days from submission of quotation

quotations should include all necessary or recommended
 accessories.

7.11 submission of quotation

quotation should be received by cr no later than december
 19, 1982.

quotation should be sent to:

  christian rovsing a/s
  2, lautrupvang
  dk-2750  ballerup
  denmark
  attn: mr Flemming Enevoldsen

7.12 notice to cr

please confirm your intention to quote by telex to cr
 (35111 cr dk).

please by telex inform of actual submittal of quotation
 on date of your submittal.

please submit technical information without delay.

hoping that you will accept this invitation, we are looking
 forward to receiving your quotation.


yours sincerely,
christian rovsing A/S