Estimering af Maintenance-omkostninger                 SYS/84-02-28
for OEM-udstyr til CAMPS                               Side
 #  





         V̲a̲r̲i̲g̲h̲e̲d̲

         Maintenance forpligtelsen l]ber i 12 mdr. fra SPA.
         Alle 16 sites forventes SPA'es i sidste halv>r af 1984.

         F̲e̲j̲l̲r̲a̲t̲e̲

         MTBF tallene fra leverand]rene giver 1.584 fejl i alt
         p> OEM udstyr i l]bet af 1 >r.

         Dette svarer til 8,25 OEM fejl pr. site pr. md. Foruds`tningen
         er 24 timers drift, dvs. worst case. Hidtige erfaringer
         med de k]rende systemer har vist, at MTBF tallene er
         ca 20% for h]je.

         Bem`rk samtidig, at MTBF erfaringstallene er opn>et
         p> systemernes f]rste levetid. 

         En "normal" H/W fejlrate udvikler sig s>ledes:

         antal
         fejl/t





                  ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ t
                  A      B

         MTBF erfaringstallene er s>ledes baseret p> den periode
         der er m`rket A.

         Da garantiperioden falder i den periode, der er m`rket
         B (den flade del af kurven), vil det v`re en rimelig
         antagelse, at fejlraten vil v`re lavere i garantiperioden,
         end i indk]ringsperioden, f.eks. ydeligere 10-20% lavere
         fejlhyppighed. (Herefter regnes med 15% bedre MTBF)

         D̲r̲i̲f̲t̲t̲i̲d̲

         Fejlraten p> 8,25 pr. md. er baseret p> fuld 24 timers
         drift i d]gnet.

         Al st]rst betydning er erfaringsm`ssigt at systemet
         st>r t`ndt og mindre betydning om systemet kommunikerer
         lokalt, via et midlertidigt net, eller via det egentlige
         net, som skal implementeres.





         Derimod kan det med stor sikkerhed foruds`ttes, at
         drifttiden f]rst kommer op p> 24 timer i d]gnet efter
         at systemet har k]rt i nogen tid. Dette skyldes, at
         kundens folk p> de enkelte sites trods uddannelse har
         et ret ringe forh>ndskendskab til CAMPS.

         Et typisk ibrugtagningsforl]b vil s>ledes v`re:

         Periode 1   Efter modtagelse af systemet genopfrisker
                     de folk p> siten, som er uddannede til
                     CAMPS, deres viden.

                     Herefter tilrettel`gges lokale brugerkurser.

         Periode 2   Undervisning p> siten.

         Periode 3   Nyuddannede g]r sig fortrolige med systemet
                     (lokal drift).

         Periode 4   Der fors]ges med kommunikation p> de midlertidige
                     net.

         Periode 5   De egentlige net tages i brug.

         Den gennemsnitlige drifttid pr. d]gn i de fem perioder
         forventes at blive s>ledes:

         Periode 1       8 timer
         -       2      10 -
         -       3      12 -
         -       4      16 -
         -       5   20-24 -

         De enkelte sites vil sikkert have forskellig genneml]bstid
         p> de 5 perioder. 

           I F̲o̲r̲e̲g̲a̲n̲g̲s̲f̲o̲l̲k̲e̲n̲e̲ ̲o̲g̲ ̲e̲k̲s̲p̲e̲r̲t̲e̲r̲n̲e̲

             Her er tale om sites, hvor der er stor (ledelsesm`ssig)
             interesse for at f> CAMPS i drift, f.eks. NATO
             og SHAPE.

          II G̲e̲n̲e̲r̲e̲l̲t̲ ̲a̲k̲t̲i̲v̲e̲

             Mellemgruppen. Her forventes normal interesse og
             normal ibrugstagning uden de store problemer.





         III D̲e̲n̲ ̲t̲u̲n̲g̲e̲ ̲e̲n̲d̲e̲

             Efter al sandsynlighed vil en del af sitene af
             forskellige >rsager komme langsomt igang, bl.a.
             p.g.a. mgl. uddannelse, underbemanding, lav motivation
             m.v.

         Gruppe   I  formodes at n> alle 5 perioder i l]bet
                     af garantiperioden

         Gruppe  II  n>r formodentlig ikke l`ngere end gennem
                     periode 4

         Gruppe III  n>r ikke l`ngere end periode 3

         I det f]lgende foruds`ttes de 16 sites at v`re fordelt
         s>ledes:

         Gruppe   I: 4 sites
         Gruppe  II: 6 -
         Gruppe III: 6 -





         Belastningsprofilerne for de 3 grupper bliver s>lede

                         G̲r̲u̲p̲p̲e̲ ̲I̲

                          V̲a̲r̲i̲g̲h̲e̲d̲ ̲(̲m̲d̲)̲        G̲n̲s̲ ̲d̲r̲i̲f̲t̲ ̲t̲i̲d̲/̲d̲]̲g̲n̲

         Periode 1         2                    8
         Periode 2         2                   10
         Periode 3         3                   12
         Periode 4         3                   16
         Periode 5         ̲2̲                   22

                          12

                        G̲r̲u̲p̲p̲e̲ ̲I̲I̲

                          V̲a̲r̲i̲g̲h̲e̲d̲ ̲(̲m̲d̲)̲        G̲n̲s̲ ̲d̲r̲i̲f̲t̲ ̲t̲i̲d̲/̲d̲]̲g̲n̲

         Periode 1         3                    8
         Periode 2         3                   10
         Periode 3         3                   12
         Periode 4         3                   16
         Periode 5         ̲0̲

                          12

                        G̲r̲u̲p̲p̲e̲ ̲I̲I̲I̲

                          V̲a̲r̲i̲g̲h̲e̲d̲ ̲(̲m̲d̲)̲        G̲n̲s̲ ̲d̲r̲i̲f̲t̲ ̲t̲i̲d̲/̲d̲]̲g̲n̲

         Periode 1         3                    8
         Periode 2         4                   10
         Periode 3         5                   12
         Periode 4         0                   16
         Periode 5         ̲0̲                   22

                          12

         Den gennemsnitlige drigtbelastning pr. d]gn i garantiperioden
         bliver s>ledes for de 3 grupper.

         Gruppe   I:      13,8 t/d]gn
         Gruppe  II:      11,5 t/d]gn
         Gruppe III:      10,3 t/d]gn

         Vejet gns. for alle sites

         (4 x 13,8 + 11,5 x 6 + 10,3 x 6) - 16 = 11,6 t/d]gn.





         J̲u̲s̲t̲e̲r̲i̲n̲g̲ ̲a̲f̲ ̲f̲e̲j̲l̲r̲a̲t̲e̲n̲

         Fejlraten pr. md. baseret p> 24 t. drift og teoretiske
         MTBF'er var 8,25 pr. site pr. md.

         Reduceret i forhold til den gennemsnitlige drifttid
         f>s en fejlrate p>: 

         8,25 x …0e…1̲1̲,̲6̲ = 3,99.
                  24     

         Justeres der ligeledes for den konstaterede/forventede
         forskel p> teoretisk MTBF og erfaret MTBF f>s (i f]lge
         s. 1) en reduktion i fejlraten p> 20 + 15% = 35%. S>ledes

         3.99 x (1 -  .35) = 2,6 fejl pr. site pr. md.

         Der tages i̲k̲k̲e̲ hensyn til f]lgende forhold:

         1.  Koldstart som f]lge af drifttid under 24 t/d]gn.

         2.  Mgl. systemkendskab medf]rer at fejl ikke erkendes
             som fejl.

         3.  Flere fejl i samme enhed.

         4.  Mgl. fejlmulighed i enheden, n>r den st>r stille
             p.g.a. reperationstiden (op til 3 mdr.).

         O̲m̲k̲o̲s̲t̲n̲i̲n̲g̲e̲r̲

         Omkostninger for CR i forbindelse med fejlrettelse
         i garantiperioden bygger p> f]lgende foruds`tninger:

         CR skal kun d`kke egentlige reparationsomkostninger,
         dvs. modtagelse, reparation og test af fejlede enheder.

         Identifikation af fejlen ned til modulniveau foruds`ttes
         udf]rt af SHAPE.

         SHAPE skal desuden selv foretage reparation, dvs. udskiftning
         af consumerables, f.eks. sikringer.

         1/3 af garantiperioden forventes at falde i 1984 og
         2/3 i 1985. Heraf afledt pris escalation:

                     i̲n̲d̲e̲x̲

         1984        108
         1985        116





         Basis reparationsomkostninger foruds`ttes s>ledes:
         

         Materialer  500 kr. pr. fejl
         L]n E2      2 timer a 95,- pr. fejl
         L]n T       1 time a 90,- pr. fejl

         Reparationsomkostninger pr. site pr. md. bliver:

         Materialer: 2,6 x 500      =  1300
         L]n E 2:    2,6 x 2 x 95,- =   494
         L]n E 2:    2,6 x 90,-     =   ̲2̲3̲4̲

         Sum pr. site pr. md.         2.028

         Cost pr. md. for alle sites 16 x 2.028 =  32.448

         Cost i 84: 1/3 x 12 x 32.448           = 129.792
         Cost i 85: 2/3 x 12 x 32.448           = 259.584

         Escaleret cost i 84 = 1.08 x 129.792   = 140.175
         -         -    - 85 = 1.16 x 259.584   = 3̲0̲1̲.̲1̲1̲7̲

         Total Cost; alle 16 sites i hele
         garantiperioden                        = 4̲4̲1̲.̲2̲9̲2̲




         Svend Thomsen















         NB: Til orientering kan yderligere oplyses, at for
             CR80 udslys er den erfaringsm`ssige MTBF i ]jeblikket
             3 gange s> god som den teoretiske MTBF.