formed are described in the following sections.



4.2.5.1.1 V̲D̲U̲ ̲C̲o̲n̲t̲r̲o̲l̲

 The VDU Control functions are detailed in figure 4.2.5.1.1-1.



4.2.5.1.1.1 S̲i̲g̲n̲-̲O̲n̲

 The Sign-on functions are decomposed as defined in figure 4.2.5.1.1.1-1 overleaf.

 Th Sign-on command will result in a log record.

 If the user depresses the SYSTEM key and enters the command SION, COPSY prompts the
 user for the identification code and the password in the system line.

 On entry the characters are not displayed.

If either one or both are invalid, COPSY responds by displaying error message 1 (INVALID
 ENTRY) in the system line.

 For the two supervisor positions it is not checked if ID code entered is contained
 in the operator list of the terminal profile.

The absence of a reply within 3 minutes or if after three attempts a valid entry is
 not made, COPSY blocks the keyboard (supervisor terminal positions are not blocked),