top - download
⟦4cf7e4d81⟧ Wang Wps File
Length: 9108 (0x2394)
Types: Wang Wps File
Notes: CPS/OPM/002 (V)
Names: »2679A «
Derivation
└─⟦5254aaab5⟧ Bits:30006166 8" Wang WCS floppy, CR 0227A
└─ ⟦this⟧ »2679A «
WangText
…19……00……00……00……00…2…0a……00……00…2…86…1 …02… …02… …02…
2679A/rt …02… CPS/OPM/002
…02… CLA/840406 …02…
CAMPS SUPERVISOR OPERATION MANUAL
…02… Issue 3…02… CAMPS
3.2.12 S̲y̲s̲t̲e̲m̲ ̲P̲a̲r̲a̲m̲e̲t̲e̲r̲ ̲C̲o̲n̲t̲r̲o̲l̲
3.2.12.1 S̲y̲s̲t̲e̲m̲ ̲P̲a̲r̲a̲m̲e̲t̲e̲r̲ ̲C̲o̲n̲t̲r̲o̲l̲ ̲M̲e̲n̲u̲ (SYPC)
The menu to this section will give you the possibility
for control of different system parameters like:
- PRINTER/PUNCHER
- CHANNELS
- ACP 127 (allied communication procedures)
- MESSAGE DISTRIBUTION
- SPECIAL DISTRIBUTION
- CRISES INDICATOR
- QUIET HOURS
- FLASH QUEUE
- CAMPS INFORMATION FILE
- CAMPS De RI
- STATISTICS PRINT
3.2.12.2 P̲r̲i̲n̲t̲/̲P̲u̲n̲c̲h̲ ̲P̲a̲r̲a̲m̲e̲t̲e̲r̲ ̲C̲o̲n̲t̲r̲o̲l̲ (PPPC)
PRINT/PUNCH PARAMETER CONTROL is part of the system
parameter control.
This section enables you to:
- Specify the number of lines per page and between
pages for the printers.
- Specify how many seconds a message must be delayed
before writing out must take place.
In the format, you can jump forward or backward by
moving the cursor to the desirable entries.
After validation, if the systems finds an invalid entry,
an error message number will appear in the left hand
margin on a level with the field in question.
The actual field will be highlighted (reversed video).
You must correct your mistake by inserting valid data.
If you need further error number explanation, proceed
to the error messages and error handling section.
3.2.12.3 C̲h̲a̲n̲n̲e̲l̲ ̲P̲a̲r̲a̲m̲e̲t̲e̲r̲ ̲C̲o̲n̲t̲r̲o̲l̲ (CHPC)
CHANNEL PARAMETER CONTROL is part of the system parameter
control.
This section enables you to specify how often the system
must send and receive channel messages and channel
check messages.
In the format, you can jump forward or backward by
moving the cursor to the desirable entries.
After validation, if the system finds an invalid entry,
an error message number will appear in the left hand
margin on a level with the field in question.
The actual field will be highlighted (reversed video).
You must correct your mistake by inserting valid data.
If you need further error number explanation, proceed
to the error messages and error handling section.
3.2.12.4 A̲C̲P̲ ̲1̲2̲7̲ ̲P̲a̲r̲a̲m̲e̲t̲e̲r̲ ̲C̲o̲n̲t̲r̲o̲l̲ (ACPC)
ACP 127 PARAMETER CONTROL is part of the system parameter
control.
This section enables you to specify different information
used in the heading part of ACP 127 messages.
In the format, you can jump forward or backward by
moving the cursor to the desirable entries.
After validation, if the system finds an invalid entry,
an error message number will appear in the left hand
margin on a level with the field in question.
The actual field will be highlighted (reversed video).
You must correct your mistake by inserting valid data.
If you need further error number explanation, proceed
to the error messages and error handling section.
3.2.12.5 M̲e̲s̲s̲a̲g̲e̲ ̲D̲i̲s̲t̲r̲i̲b̲u̲t̲i̲o̲n̲ ̲P̲a̲r̲a̲m̲e̲t̲e̲r̲ ̲C̲o̲n̲t̲r̲o̲l̲ (MDPC)
MESSAGE DISTRIBUTION PARAMETER CONTROL is part of the
system parameter control.
This section enables you to specify which types of
messages which must be routed to the MDCO.
In the format, you can jump forward or backward by
moving the cursor to the desirable entries.
After validation, if the system finds an invalid entry,
an error message number will appear in the left hand
margin on a level with the field in question.
The actual field will be highlighted (reversed video).
You must correct your mistake by inserting valid data.
If you need further error number explanation, proceed
to the error messages and error handling section.
3.2.12.6 S̲p̲e̲c̲i̲a̲l̲ ̲D̲i̲s̲t̲r̲i̲b̲u̲t̲i̲o̲n̲ ̲P̲a̲r̲a̲m̲e̲t̲e̲r̲ ̲C̲o̲n̲t̲r̲o̲l̲ (SDPC)
SPECIAL DISTRIBUTION PARAMETER CONTROL is part of the
system parameter control.
This section enables you to:
- Specify which devices, crypto messages must be
handled on.
- Specify the printer for messages of category ATOMAL.
In the format, you can jump forward or backward by
moving the cursor to the desirable entries.
After validation, if the system finds an invalid entry,
an error message number will appear in the left hand
margin on a level with the field in question.
The actual field will be highlighted (reversed video).
You must correct your mistake by inserting valid data.
If you need further error number explanation, proceed
to the error messages and error handling section.
3.2.12.7 S̲e̲t̲ ̲C̲r̲i̲s̲i̲s̲ ̲I̲n̲d̲i̲c̲a̲t̲o̲r̲ ̲O̲n̲ (CION)
SET CRISIS INDICATOR ON is part of the system parameter
control.
If you have selected CION, the system will change from
NORMAL time column to CRISIS time column in the SIC-Table.
If you need error/report explanation, proceed to the
error messages and error handling section or reports
and report handling section respectively.
3.2.12.8 S̲e̲t̲ ̲C̲r̲i̲s̲i̲s̲ ̲I̲n̲d̲i̲c̲a̲t̲o̲r̲ ̲O̲f̲f̲ (CIOF)
SET CRISIS INDICATOR OFF is part of the system parameter
control.
If you have selected CIOF, the system will change from
CRISIS time column to NORMAL time column in the SIC-Table.
If you need error/report explanation, proceed to the
error messages and error handling section or reports
and report handling section respectively.
3.2.12.9 S̲e̲t̲ ̲Q̲u̲i̲e̲t̲-̲H̲o̲u̲r̲ ̲T̲e̲r̲m̲i̲n̲a̲l̲ (SQHT)
SET QUIET-HOUR TERMINAL is part of the system parameter
control.
If you have selected SQHT, "quiet hours" begin and
the specified terminal designator (TD) is the nominated
terminal during this period.
If you need error/report explanation, proceed to the
error messages and error handling section or reports
and report handling section respectively.
3.2.12.10 S̲e̲t̲ ̲Q̲u̲i̲e̲t̲-̲H̲o̲u̲r̲ ̲O̲F̲F̲ (SQHO)
SET QUIET-HOUR OFF is part of the system parameter
control.
If you have selected SQHO, the system will react as
"quiet hours" are finished.
If you need error/report explanation, proceed to the
error messages and error handling section or reports
and report handling section respectively.
3.2.12.11 S̲e̲t̲ ̲F̲l̲a̲s̲h̲ ̲Q̲u̲e̲u̲e̲ ̲T̲i̲m̲e̲ ̲O̲u̲t̲ (FLQT)
SET FLASH QUEUE TIME OUT is part of the system parameter
control.
If you have selected FLQT, the system sets the flash
queue timeout in the period you entered in the specified
NN. NN must either be 30 (30 seconds) or one of the
following minutes: 5, 10, or 15.
If you need error/report explanation, proceed to the
error messages and error handling section or reports
and report handling section respectively.
3.2.12.12 C̲L̲O̲S̲E̲ ̲L̲O̲G̲ ̲C̲I̲F̲ ̲(̲L̲G̲C̲L̲)̲
CLOSE LOG CIF is part of the system parameter control.
If you have selected LGCL, the system will close the
CIF (CAMPS information file) where log records have
been inserted for the last 10 minutes. The contents
will be printed at your LOG printer.
If you need error explanation, proceed to the error
messages and error handling section.
3.2.12.13 C̲A̲M̲P̲S̲ ̲D̲E̲ ̲R̲I̲-̲C̲O̲N̲T̲R̲O̲L̲ (DRIC)
CAMPS DE RI-CONTROL is part of the System Parameter
Control.
This section enables you to define routing indicators
used for FL3 ACP127 conversion.
In the format, you can jump forward or backward by
moving the cursor to the desirable entries.
After validation, if the system finds an invalid entry,
an error message number will appear in the left hand
margin on a level with the field in question.
The actual field will be highlighted (reversed video).
You must correct your mistake by inserting valid data.
If you need further error number explanation proceed
to the error messages and error handling section.
3.2.12.14 S̲T̲A̲T̲I̲S̲T̲I̲C̲S̲ ̲P̲R̲I̲N̲T̲ ̲O̲N̲ (STON)
STATISTICS PRINT ON is part of the system parameter
control.
If you have selected STON, the system will automatically
print out statistics information at fixed intervals.
For instance each day at 24:00 hour. Also weekly and
monthly statistics will be printed at the end of the
corresponding periods.
If you need error explanation, proceed to the error
messages and error handling section.
3.2.12.15 S̲T̲A̲T̲I̲S̲T̲I̲C̲S̲ ̲P̲R̲I̲N̲T̲ ̲O̲F̲F̲ (STOF)
STATISTICS PRINT OFF is part of the system parameter
control.
If you have selected STOF, the system will be informed
n̲o̲t̲ to print out statistics information.
If you need error explanation, proceed to the error
messages and error handling section.…86…1 …02… …02…
…02… …02… …02… …02…