to cover CAMPS specifications. CDC is willing to perform field tests on samples from
production line, but are not able to perform factory testing for frequency variation
impact. Additional tests shall be performed on systems composed by CR80-contoller
and CDC disk drives.
Cost impact: Tests are needed to support the spe-
cifications of graceful degradation.
Comment: CR is willing to give a proposal for
the tests. The test requirements should
be discussed CR/SAPE. CR asks for SHAPE
opinion.
3. Informations on the actual configuration and the CDC/SMD9762 disks:
3.1 Start-up current consumption is shown on the curve
of appendix.
Initial peak current is not shown. When rating Uninterrupted
Power Supply (UPS) based on Static inverters, th compatibility
of the UPS-design with the disk system should be checked
carefully. An increase in the UPS-power rating with
a factor three to the start-up power may be necessary.
3.2 If disk drives are powered from separate power inputs,
these