CAMPS
 SYSTEM
 REQUIREMENTS
…02…ISSUE
 3.6…02…CAMPS















                 T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲ ̲
                   S̲e̲c̲t̲i̲o̲n̲ ̲3̲.̲4̲.̲2̲



…02……02……02…3.4.2  Physical Characteristics  ............  247
…02……02……02……02…3.4.2.1  Size, Weight, Power Consumption
                    and Heat Dissipation  ............
  247
…02……02……02……02…3.4.2.2  Power Input  .....................  247


3.4.2…02…P̲h̲y̲s̲i̲c̲a̲l̲ ̲C̲h̲a̲r̲a̲c̲t̲e̲r̲i̲s̲t̲i̲c̲s̲


3.4.2.1  S̲i̲z̲e̲,̲ ̲W̲e̲i̲g̲h̲t̲,̲ ̲P̲o̲w̲e̲r̲ ̲C̲o̲n̲s̲u̲m̲p̲t̲i̲o̲n̲ ̲a̲n̲d̲ ̲H̲e̲a̲t̲ ̲D̲i̲s̲s̲i̲p̲a̲t̲i̲o̲n̲

         The site equipments consist of a number of terminals
         and one or two multi-bay rack assemblies.

         The racks of each site equipment will be equipped with
         subassemblies and modules according to the actual connectivity.

         Detailed technical information will be supplied in
         the System Design Specification.



3.4.2.2  P̲o̲w̲e̲r̲ ̲I̲n̲p̲u̲t̲

         The equipments shall be capable of satisfying the specified
         performance requirements when operating with following
         power input:

         a)  Phases:       Single- or 3-phase, and ground. (For
                           supply of redundant elements within
                           the equipment, the power input shall
                           be established with 2 independent
                           sources as a minimum).

         b)  Voltage:      Nominal value 380/220 V AC
                           Tolerances: +10%/-15%
                           Except UKAIR where nominal value
                           is 405/240 V AC.

         c)  Frequency:    Nominal value: 50 Hz
                           Tolerances: +10/-10%

         d)  Harmonic
             distortion:   Max. 5%

         e)  Transients:   Non-repetitive impulsive interference
                           with a magnitude not to exceed 500
                           volts, pulse rise and fall times
                           not faster than 10 microseconds and
                           a total duration of maximum 1 millisecond.
                           The available impulse energy at the
                           equipment power inlet shall not exceed
                           5J.



         f)  Exemptions:   Each site equipment will contain
                           three disk drives. These will not
                           operate within the tolerances of
                           section b) and c) above, but:

                           1)  Voltage:   Nominal value: 380/220V AC
                                          Tolerances: +6%/-10%

                           2)  Frequency: Nominal value: 50 Hz
                                          Tolerance: +0,5 Hz/-1.0 Hz

             In order to meet these special tolerance requirements
             voltage/frequency stabilizers shall be inserted
             in the power lines for the disk drives.

             Frequency Stabilizers shall be delivered for installation
             at all non-optional sites of figure 3.4.1.7.1 except
             BALTAP, WEST STAR, and NATO.

             For UKAIR see para 3.7.1.2.4.


         g)  Exemptions:   Each site will contain a number of
                           Medium Speed Printers. These will
                           not operate within the tolerances
                           of section b) and c) above, but:

                           1)  Voltage:   Nominal value: 240/220V
                                          AC
                                          Tolerances: +10%/-15%

                           2)  Frequency: Nominal value: 50
                                          Hz
                                          Tolerance: +5 Hz/-3
                                          Hz




3.4.2.3  T̲e̲m̲p̲e̲s̲t̲ ̲R̲a̲c̲k̲s̲

         The EMI racks are constructed of heavy gauge steel,
         having all non-opening seams welded. The racks will
         be of slightly greater size than equivalent non-EMI
         racks and will be significantly heavier. Cable entrance
         for power and signals will be either through the top
         or bottom of each rack. The racks are prepared for
         both type of outlet.



         a)  R̲a̲c̲k̲ ̲C̲o̲n̲f̲i̲g̲u̲r̲a̲t̲i̲o̲n̲

             The racks will be used as a single, free-standing
             cabinet or assembled into bays of 2, 3, 4, or more
             racks in a row forming a cabinet.

             The individual racks will be transported separately
             and joined with coupling accessories at site. Thus,
             four rack types are defined.

             1)  L̲E̲F̲T̲ ̲E̲N̲D̲ ̲R̲A̲C̲K̲S̲, which includes one welded panelled
                 side and one open side with joiner frame, hardware,
                 and accessories.

             2)  I̲N̲T̲E̲R̲M̲E̲D̲I̲A̲T̲E̲ ̲R̲A̲C̲K̲, which includes both sides
                 open, but with only one joiner frame, hardware,
                 and accessories.

             3)  R̲I̲G̲H̲T̲ ̲E̲N̲D̲ ̲R̲A̲C̲K̲, which includes one open side
                 without joiner frame and one welded panelled
                 side and accessories.

             4)  F̲R̲E̲E̲-̲S̲T̲A̲N̲D̲I̲N̲G̲ ̲R̲A̲C̲K̲, which includes both sides
                 welded panelled, and accessories.

         The types of racks are non interchangeable, left cannot
         be interchanged with right, a freestanding cannot be
         changed to a right, etc.

         b)  R̲a̲c̲k̲ ̲D̲o̲o̲r̲s̲

             Each rack shall have a full size door in front
             and rear. Doors will be operated with recessed
             handles. The doors shall contain EMI gaskets.

         c)  R̲a̲c̲k̲ ̲V̲e̲n̲t̲i̲l̲a̲t̲i̲o̲n̲

             To allow ventilation and EMI shielding, perforated
             metal is used. The perforated areas are located
             in the front doors and at the top.

         d)  A̲C̲ ̲P̲o̲w̲e̲r̲ ̲F̲i̲l̲t̲e̲r̲s̲

             RF power filters shall be used, and they shall
             be mounted directly to either the top or bottom
             of racks.



         e)  I̲n̲t̲e̲r̲m̲e̲d̲i̲a̲t̲e̲ ̲D̲i̲s̲t̲r̲i̲b̲u̲t̲i̲o̲n̲ ̲F̲r̲a̲m̲e̲ ̲(̲I̲D̲F̲)̲

             The IDF shall be enclosed within one of the main
             frame EMI racks. It provides access to all input
             and output electrical signal connections to the
             CAMPS mainframe. Filtered connectors will be installed
             in the IDF as described below to meet AMSG requirements.

             The IDF consists of a separately shielded box sealed
             to the rack surface within an EMI rack into which
             conduit or ducts from all external electrical signal
             cables are passed. Upon removal of the IDF cover,
             52 banks of 25 pin connectors are accessible for
             user connection. Optical signal cables are fed
             through a wavequide placed separately or contained
             in the IDF.

             Rack cable connections between the multi-bay rack
             assemblies shall be passed in tubes sealed to the
             racks.

         f)  V̲2̲8̲(̲L̲)̲-̲A̲d̲a̲p̲t̲e̲r̲s̲ ̲f̲o̲r̲ ̲D̲r̲i̲v̲i̲n̲g̲ ̲E̲l̲e̲c̲t̲r̲i̲c̲a̲l̲ ̲C̲a̲b̲l̲e̲s̲

             The V28(L) shall provide 6-0-6 volts signal levels
             and waveshaping.

             2 types shall be provided.

             The first type shall cover the range up to 1200
             BPS. The second type shall cover the range up to
             9600 Bps.








                 T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲
                   S̲e̲c̲t̲i̲o̲n̲ ̲3̲.̲4̲.̲3̲



…02……02……02…3.4.3  Environmental Conditions  ............  250
…02……02……02……02…3.4.3.1  Temperature and Humidity  ........  250
…02……02……02……02…3.4.3.2  Dust, Fumes  .....................  251


3.4.3…02…E̲n̲v̲i̲r̲o̲n̲m̲e̲n̲t̲a̲l̲ ̲C̲o̲n̲d̲i̲t̲i̲o̲n̲s̲

         In designing the equipment to meet the specified requirements
         no account need be taken of catastrophic events such
         as fire, flood, explosion, etc., which are beyond the
         control of an equipment manufacturer.

         The equipment will normally operate within accomodation
         suitable for the operation of similar equipment produced
         for commercial use.

         After initial adjustments have been made, the equipment
         shall maintain normal operation under all specified
         environmental and power supply conditions.



3.4.3.1 …02…T̲e̲m̲p̲e̲r̲a̲t̲u̲r̲e̲ ̲a̲n̲d̲ ̲H̲u̲m̲i̲d̲i̲t̲y̲

         The equipment shall continue to function when the humidity
         and temperature of its environment are within the ranges
         and cycling specified below.

         The equipment shall continue to operate in a fully
         satisfactory manner even under the worst conditions
         specified below.

…02…a) T̲e̲m̲p̲e̲r̲a̲t̲u̲r̲e̲                      

…02……02…Range  :  10 to 40 deg.C
…02……02…Change :  max 10 deg. C per hour

…02…b) H̲u̲m̲i̲d̲i̲t̲y̲ ̲(̲R̲e̲l̲a̲t̲i̲v̲e̲ ̲H̲u̲m̲i̲d̲i̲t̲y̲ ̲=̲ ̲R̲H̲)̲

…02……02…Range  :  40 to 90% RH, non-condensing
…02……02…Change :  max. 6% RH per hour, non-condensing

…02…c) A̲l̲t̲i̲t̲u̲d̲e̲

…02……02…Range  :  Sea level to 2000 meter

         The equipment shall be so designed that the loss of
         site air conditioning or heating will not cause a catastrophic
         failure within 15 minutes after the loss.

         An alarm indication shall be given, when the environmental
         temperature reaches a value which will require intervention
         of supervisory personnel.




3.4.3.2  D̲u̲s̲t̲,̲ ̲F̲u̲m̲e̲s̲

         The equipment shall be able to operate continuously
         and with normal scheduled preventive maintenance in
         the following air environment:

         a)  Ai̲r̲ ̲c̲l̲e̲a̲n̲n̲e̲s̲s̲

             Particle size            Max. allowable number
             (̲m̲i̲c̲r̲o̲n̲s̲)̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲(̲p̲a̲r̲t̲i̲c̲l̲e̲s̲/̲c̲u̲b̲i̲c̲m̲e̲t̲e̲r̲)̲

             greater than 5           4* (10 5)
             greater than 1.5         4* (10 6)
             greater than 1           4* (10 7)

         b)  F̲u̲m̲e̲s̲

             sulphur dioxide max. 14 ppm.


          T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲…01…S̲e̲c̲t̲i̲o̲n̲ ̲3̲.̲4̲.̲4̲



…02……02……02…3.4.4  Availability and Maintainability  ....  253
…02……02……02……02…3.4.4.1  General  .........................  253
…02……02……02……02…3.4.4.2  Reliability Characteristics  .....  253
…02……02……02……02…3.4.4.3  Availability Calculation  ........  253
…02……02……02……02…3.4.4.4  Availability and Reliability
                    Performance Requirements  ........
  254
…02……02……02……02……02…3.4.4.4.1  User Connecting Point  .......  254
…02……02……02……02……02…3.4.4.4.2  Individual User Connecting
                        Points  ......................
  255
…02……02……02……02……02…3.4.4.4.3  Groups of User Connecting
                        Points  ......................
  255
…02……02……02……02……02…3.4.4.4.4  User Connecting Points to
                        Supervisory and Service
                        Terminals  ...................
  255
…02……02……02……02……02…3.4.4.4.5  External Channels and
                        Circuits  ....................
  256
…02……02……02……02……02…3.4.4.4.6  Individual Channels  .........  256
…02……02……02……02……02…3.4.4.4.7  Groups of Channels  ..........  256
…02……02……02……02……02…3.4.4.4.8  All Circuits, Channels and
                        User Connecting Points  ......
  256

…02……02……02……02…3.4.4.5  Equipment Redundancy  ............  257
…02……02……02……02……02…3.4.4.5.1  Withdrawal of Redundant
                        Items  .......................
  257
…02……02……02……02……02…3.4.4.5.2  Loss of Redundancy  ..........  258

…02……02……02……02…3.4.4.6  Specific Equipment Availability
                    Requirements  ....................
  258
…02……02……02……02…3.4.4.7  Terms  ...........................  258


3.4.4    A̲v̲a̲i̲l̲a̲b̲i̲l̲i̲t̲y̲ ̲a̲n̲d̲ ̲M̲a̲i̲n̲t̲a̲i̲n̲a̲b̲i̲l̲i̲t̲y̲



3.4.4.1  G̲e̲n̲e̲r̲a̲l̲

         Availability and maintainability requirements apply
         to the equipment excluding environmental control equipment,
         primary power supply to the equipment, and other purchaser
         supplied equipment.

         The equipment will meet the specified requirements:

         a)  When operating in a support environment which lies
              within the limits of the specified operating requirements
             of the equipment.

         b)  When tools, repair parts, manuals, manpower, etc.
             required for maintenance are available.

         In designing the equipment to meet the specified requirements
         no account need to be taken to catastrophic events
         such as fire, flood, explosion, etc. which are beyond
         the control of the equipment manufacturer.

         The definitions of the terms used in this section are
         given in section 3.4.4.7.



3.4.4.2  R̲e̲l̲i̲a̲b̲i̲l̲i̲t̲y̲ ̲C̲h̲a̲r̲a̲c̲t̲e̲r̲i̲c̲t̲i̲c̲s̲

         The reliability of the equipment is specified in terms
         of its availability. The equipment is partitioned into
         modules and units, which are used for construction
         of the R & M models and block diagrams. A separate
         analysis shall be conducted for each module performance
         requirement specified below.



3.4.4.3  A̲v̲a̲i̲l̲a̲b̲i̲l̲i̲t̲y̲ ̲C̲a̲l̲c̲u̲l̲a̲t̲i̲o̲n̲

         The inherent availability of a module or unit shall
         be measured in terms of two parameters:

         - Mean time between failure (MTBF)

         - Mean time to repair (MTTR)



         The availability of a module or unit shall be determined
         from the formula

             Ai =      ̲ ̲ ̲ ̲ ̲M̲T̲B̲F̲i̲ ̲ ̲ ̲ ̲ ̲
                      MTBFi  +  MTTRi

         The availability value associated with each reliability
         performance requirements, specified in succeeding paragraphs
         of this section, shall be determined from a R&M model
         and block diagram by combining the availability co-efficients
         for the modules and units affecting that availability
         performance requirement. The availability co-efficient
         for a series configuration shall be calculated by:

                         elements ̲ ̲     
         A (system)=             ll Ai
                             i=1

         where Ai is the availability co-efficient of the i…09…th
         element.

         In the case of modules and units provided for the purpose
         of redundancy (e.g. duplicated units) the availability
         co-efficient shall be calculated by:

         a)  For (N-1) out of N redundancy is the availability
             for (N-1) out of N being operative:
                                                           …0f…MTTR…0e…
             
             A(N-1 out of N operative) = 1 - N * (N-1) * (------)…0e…2…0f…
                                                           …0e…MTBF…0f…
             

             where MTTR   MTBF.

         b)  For other types of redundancy the availability
             shall be calculated using the R&M model. Assumptions
             made shall be justified.


3.4.4.4  A̲v̲a̲i̲l̲a̲b̲i̲l̲i̲t̲y̲ ̲a̲n̲d̲ ̲R̲e̲l̲i̲a̲b̲i̲l̲i̲t̲y̲ ̲P̲e̲r̲f̲o̲r̲m̲a̲n̲c̲e̲ ̲R̲e̲q̲u̲i̲r̲e̲m̲e̲n̲t̲s̲



3.4.4.4.1    U̲s̲e̲r̲ ̲C̲o̲n̲n̲e̲c̲t̲i̲n̲g̲ ̲P̲o̲i̲n̲t̲

         The demarcation point between terminals and the equipment
         is the user connecting point.  The availability of
         service shall be measured at the user connecting point
         of the equipment, to which each terminal is attached.



3.4.4.4.2    I̲n̲d̲i̲v̲i̲d̲u̲a̲l̲ ̲U̲s̲e̲r̲ ̲C̲o̲n̲n̲e̲c̲t̲i̲n̲g̲ ̲P̲o̲i̲n̲t̲s̲

         a)  The availability of the subset of the equipment
             which provides service to each user connecting
             point shall be at least .9995.

         b)  The MTBF of a failure which causes loss of service
             to a single user connecting point shall be at least
             3 months with an MTTR not to exceed 40 mins.



3.4.4.4.3    G̲r̲o̲u̲p̲s̲ ̲o̲f̲ ̲U̲s̲e̲r̲ ̲C̲o̲n̲n̲e̲c̲t̲i̲n̲g̲ ̲P̲o̲i̲n̲t̲s̲

         It shall be possible to select user connecting points
         in groups in such a way that no single failure shall
         cause loss of service to more than one such group.
         Within the expansion capacity specified in this document,
         the maximum number of user connecting points in such
         a group is 8.

         The equipment shall be designed such that no single
         failure can cause loss of service to 25% or more user
         connecting points.

         a)  The availability of the subset of the equipment
             at the maximum expanded configuration which provides
             service to 75% or more of the user connecting points
             shall be at least 0.9999.

         b)  The MTBF of a failure which causes loss of service
             to 25% or more user connecting points of the maximum
             expanded configuration shall be at least 1 year
             with an MTTR not to exceed 1 hour.



3.4.4.4.4    U̲s̲e̲r̲ ̲C̲o̲n̲n̲e̲c̲t̲i̲n̲g̲ ̲P̲o̲i̲n̲t̲s̲ ̲t̲o̲ ̲S̲u̲p̲e̲r̲v̲i̲s̲o̲r̲y̲ ̲a̲n̲d̲ ̲S̲e̲r̲v̲i̲c̲e̲
             ̲T̲e̲r̲m̲i̲n̲a̲l̲s̲

         It shall be possible to divide the connecting points
         providing service to the terminals of the supervisory
         and service positions into more than one group.

         a)  The availability of the subset of the equipment
             which provides service to any such group shall
             be at least 0.9999.



         b)  The MTBF of a failure which causes loss of service
             to such a group shall be at least 1 year with an
             MTTR not to exceed 1 hour.



3.4.4.4.5    E̲x̲t̲e̲r̲n̲a̲l̲ ̲C̲h̲a̲n̲n̲e̲l̲s̲ ̲a̲n̲d̲ ̲C̲i̲r̲c̲u̲i̲t̲s̲

         Availability of service to external channels circuits
         shall be measured at the connection point of the equipment,
         to which each circuit is attached.



3.4.4.4.6    I̲n̲d̲i̲v̲i̲d̲u̲a̲l̲ ̲C̲h̲a̲n̲n̲e̲l̲s̲

         1)  The availability of the subset of the equipment
             which provides service to each incoming or outgoing
             channel shall be at least .9995.

         2)  The MTBF of a failure which causes loss of service
             to a single incoming or outgoing channel shall
             be at least 3 months with an MTTR not to exceed
             40 mins.



3.4.4.4.7    G̲r̲o̲u̲p̲s̲ ̲o̲f̲ ̲C̲h̲a̲n̲n̲e̲l̲s̲

         It shall be possible to divide outgoing channels and
         incoming channels each into at least two groups such
         that no single failure shall cause loss of service
         to more than one such group.

         a)  The availability of the subset of the equipment
             which provides service to any such group of external
             connections of the maximum configuration shall
             be at least 0.9999. The requirement shall be met
             separately for incoming and outgoing channels.

         b)  The MTBF of a failure which causes loss of service
             to any such group of external connections shall
             be at least 1 year with an MTTR not to exceed 1
             hour.



3.4.4.4.8    A̲l̲l̲ ̲C̲i̲r̲c̲u̲i̲t̲s̲,̲ ̲C̲h̲a̲n̲n̲e̲l̲s̲ ̲a̲n̲d̲ ̲U̲s̲e̲r̲ ̲C̲o̲n̲n̲e̲c̲t̲i̲n̲g̲ ̲P̲o̲i̲n̲t̲s̲

         No single failure shall cause a total system failure.



         a)  The availability of the subset of the equipment
             which provides service to all user connecting 
             points and external circuits shall be at least
             0.99995.

         b)  The MTBF of a failure which causes loss of service
             to all external circuits and user connecting points
             shall be at least 2 years with an MTTR not to exceed
             1 hour.



3.4.4.5  E̲q̲u̲i̲p̲m̲e̲n̲t̲ ̲R̲e̲d̲u̲n̲d̲a̲n̲c̲y̲



3.4.4.5.1    W̲i̲t̲h̲d̲r̲a̲w̲a̲l̲ ̲o̲f̲ ̲R̲e̲d̲u̲n̲d̲a̲n̲t̲ ̲I̲t̲e̲m̲s̲

         It is acceptable that redundant modules and units can
         be withdrawn from use by the operational configuration
         in order to perform:

         a)  Preventive maintenance

         b)  Execution of test programmes

         c)  Loading and check-out of new software

         d)  On-job training

         e)  Training/exercise with alternative procedures.

         provided that:

         -   a failure, while in the degraded availability state,
             shall not result in the loss of operational messages
             and transaction accountability.

         -   the capability is maintained to re-integrate such
             redundant items into the operational configuration
             and return them to service within 5 minutes.





3.4.4.5.2    L̲o̲s̲s̲ ̲o̲f̲ ̲R̲e̲d̲u̲n̲d̲a̲n̲c̲y̲

         With respect to redundant modules or units provided
         to meet the availability and reliability requirements,
         no failure shall result in the equipment being without
         the complete planned degree of redundancy for longer
         than 6 hours more than once a year.



3.4.4.6  S̲p̲e̲c̲i̲f̲i̲c̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲ ̲A̲v̲a̲i̲l̲a̲b̲i̲l̲i̲t̲y̲ ̲R̲e̲q̲u̲i̲r̲e̲m̲e̲n̲t̲

         a)  The reliability requirements with respect to contractor
             supplied terminal equipment connected to the processor
             equipment shall be as follows:

             1)  M̲e̲d̲i̲u̲m̲ ̲S̲p̲e̲e̲d̲ ̲P̲r̲i̲n̲t̲e̲r̲

                 MTBF:          3000 hrs

                 Downtime:      not to exceed 30 mins. per month
                                excluding preventive maintenance.

             2)  V̲D̲U̲

                 MTBF:          5000 hrs.

                 Downtime:      not to exceed 30 mins. per month
                                including preventive maintenance.



3.4.4.7  T̲e̲r̲m̲s̲

         In interpreting specification and verification sections
         in this paper on reliability and availability the following
         terms shall apply:

         a)  A̲v̲a̲i̲l̲a̲b̲i̲l̲i̲t̲y̲. The probability of finding an item
             (system, module, unit and part thereof) in a functioning
             condition at a given time.

         b)  C̲o̲r̲r̲e̲c̲t̲i̲v̲e̲ ̲M̲a̲i̲n̲t̲e̲n̲a̲n̲c̲e̲. The maintenance undertaken
             to restore an item to a specified condition after
             a failure has occurred.

         c)  D̲o̲w̲n̲ ̲T̲i̲m̲e̲. The time during which any of the facilities
             or functions to be provided by the item is not
             available, for whatever reason.



         d)  F̲a̲i̲l̲u̲r̲e̲. The inability of any item to carry out
             its specified function within the tolerance allowed
             under its normal operating conditions.

             Following failure situations shall be disregarded
             in availability calculation:

             1)  The item is or has been exposed to conditions,
                 which are not within the tolerances allowed
                 under its normal operating conditions.

             2)  The item is or has been exposed to violence.

         e)  I̲t̲e̲m̲. An item is defined as system, module, unit
             and part thereof.

         f)  M̲e̲a̲n̲ ̲T̲i̲m̲e̲ ̲B̲e̲t̲w̲e̲e̲n̲ ̲F̲a̲i̲l̲u̲r̲e̲ ̲(̲M̲T̲B̲F̲)̲. The statistical
             mean of the functioning time between failures.
              For a given interval, the total measured functioning
             time of the item divided by the total number of
             failures of that item during the interval.  Agreed
             scheduled preventive maintenance of modules of
             the equipment shall not be counted when estimating
             mean time between failure of such modules.

         g)  M̲e̲a̲n̲ ̲T̲i̲m̲e̲ ̲t̲o̲ ̲R̲e̲p̲a̲i̲r̲ ̲(̲M̲T̲T̲R̲)̲. The statistical mean
             of the distribution of times-to-repair.  The summation
             of active repair times during a given period of
             time divided by the total number of malfunctions
             during the same time interval.  This repair time
             shall include all actions required to detect, locate
             and repair the fault.

         h)  P̲r̲e̲v̲e̲n̲t̲i̲v̲e̲ ̲M̲a̲i̲n̲t̲e̲n̲a̲n̲c̲e̲. The maintenance undertaken
             systematically with the intention of keeping an
             item in a specified condition, reducing the occurrence
             of failures, and prolonging the useful life of
             the equipment.

         i)  R̲e̲l̲i̲a̲b̲i̲l̲i̲t̲y̲. The probability that an item will
             perform a required function under stated conditions
             for a stated period of time.

         k)  R̲e̲p̲a̲i̲r̲. A repair is the restoration of an item
             to the state in which it can provide its specified
             functions.

             When the item is a replaceable module or includes
             replaceable modules, the exchange operation is
             considered as the repair operation.



         l)  M̲o̲d̲u̲l̲e̲. A collection of one or more units as defined
             in this section which satisfy the following conditions:

             1)  It has a functional significance in the context
                 of R&M.

             2)  Individual failures can be localised to the
                 specific module.

             3)  The module is capable of removal and replacement.

             4)  The module operational condition has a simple
                 two state classification (operative or inoperative)
                 in the availability calculation.

         m)  U̲n̲i̲t̲. This has an exclusively functional significance
             in this R&M context.  The smallest hardware or
             software element utilized in the Reliability and
             Maintainability (R&M) models.  The set of all units,
             taken together make up the equipment.  Each unit
             shall satisfy the following conditions:

             1)  It does not contain any portion of any other
                 unit.

             2)  The failure of the unit is independent of the
                 failure of any other unit.

             3)  The unit operational condition has a simple
                 two-state classification (operative or in-operative)
                 in the availability calculation.

             4)  Corrective maintenance on failed redundant
                 parts of a unit is performed only when the
                 unit containing these parts has failed.









          T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲ ̲…01…S̲e̲c̲t̲i̲o̲n̲ ̲3̲.̲4̲.̲5̲



…02……02……02…3.4.5  Security  ............................  262
…02……02……02……02…3.4.5.1  TEMPEST Acceptance ...............  262
…02……02……02……02…3.4.5.2  Control of Record Output  ........  267
…02……02……02……02……02…3.4.5.2.1  Print-Out  ...................  267
…02……02……02……02……02…3.4.5.2.2  Punched Paper Tape  ..........  267
…02……02……02……02……02…3.4.5.2.3  Removable Storage Media  .....  268

…02……02……02……02…3.4.5.3  Accountability of Transaction  ...  268
…02……02……02……02…3.4.5.4  Supervisory Security Monitoring  .  268
…02……02……02……02…3.4.5.5  Terminal Access Control  .........  268
…02……02……02……02…3.4.5.6  Security Classification and
                    Special Handling  ................
  269
…02……02……02……02…3.4.5.7  System Design Requirements  ......  269





3.4.5    S̲e̲c̲u̲r̲i̲t̲y̲

         This section addresses or references all requirements
         related to security.

         In general: Transfer and transmission within the installation
         means transfer and transmission between the components.



3.4.5.1  T̲E̲M̲P̲E̲S̲T̲ ̲A̲c̲c̲e̲p̲t̲a̲n̲c̲e̲

         The components of the CAMPS equipment in the CAMPS
         Main Site locations are divided in the following 3
         categories.

         1)  2 multi-bay EMI-rack assemblies containing: Processor
             Unit, Channel Unit, TDX-Unit, Watch Dog Processor
             Unit, and Disk Drives.

         2)  A number of terminals for maintenance and supervisory
             positions, i.e. VDUs, medium speed printers and
             paper tape reader/puncher.

         3)  Frequency stabilizers and the auxiliary equipment.

         During short periods of corrective and preventive maintenance
         e.g. open back doors, the emanation requirements below
         are degraded.

         It must be within the operational procedures, that
         the supervisor is currently informed on activities
         concerning corrective and preventive maintenance and
         thus is able to decide whether it is acceptable to
         continue operation or not.

         a)  To meet the NATO Security requirements, the equipment,
             including ancillaries and peripherals, must be
             installed in accordance with criteria laid down
             in AMSG 719B. The production equipments shall be
             subject to inspection and testing by ACE COMSEC
             Radiation Team at the factory premises prior to
             despatch/distribution to locations. After installation,
             a final COMSEC Radiation Survey will be carried
             out at each location prior to operational approval
             being given. Rectification of the equipment characteristics
             shortcomings shall be the responsibility of the
             contractor.


         b)  Regarding of the EMI-racks, ACE COMSEC shall be
             provided with tangible evidence as to their effectiveness.
             Detailed design and manufacturing specification
             shall be forwarded to SHAPE for evaluation. Also,
             laboratory data on the shielding effectiveness
             of the rack shall be provided. Finally a Quality
             Plan shall be laid down to assure that all racks
             are manufactured to the same performance.

             ACE COMSEC has measured the ambient noise at the
             factory site at Ballerup and subject to provision
             of customer supplied power filtering accepted its
             suitability for TEMPEST test (ref. CAMPS log 091
             and CAMPS log 111). The actual TEMPEST test will
             be perfomed as a qualification test by ACE COMSEC
             at the factory site.

             1)  All equipment contained in multi-bay EMI-racks
                 assembly shall be TEMPEST cleared as a result
                 of the TEMPEST qualification test (equipment
                 of category 1 above). This shall include opto-electrical
                 interfaces.

             2)  Equipment of category 2 (terminals) will be
                 delivered with a TEMPEST clearance certification
                 according to AMSG720A with the understanding
                 that the cerfification provided will apply
                 to the standard approved version of the equipment.
                 Where modifications are required, supplementary
                 test data will be provided, to confirm that
                 the EMI integrity has been maintained.

             3)  Equipment of category 3 need not be TEMPEST
                 cleared.

             During the contract phase, technical information
             will be supplied to ACE COMSEC for evaluation and,
             where required, a production model shall be delivered
             for testing purposes.


         c)  S̲p̲e̲c̲i̲a̲l̲ ̲e̲a̲r̲t̲h̲i̲n̲g̲ ̲a̲r̲r̲a̲n̲g̲e̲m̲e̲n̲t̲s̲ with respect to 1)
             AC power neutral, 2) safety ground, 3) Signalling
             and control ground are necessary within the complete
             system in order to comply with criteria laid down
             in AMSG 719B. In the terminal equipments signal
             common returns s̲h̲a̲l̲l̲ ̲b̲e̲ ̲s̲e̲p̲a̲r̲a̲t̲e̲ ̲a̲n̲d̲ ̲i̲n̲s̲u̲l̲a̲t̲e̲d̲
             ̲f̲r̲o̲m̲ ̲a̲l̲l̲ ̲o̲t̲h̲e̲r̲ ̲e̲a̲r̲t̲h̲s̲ or metal chassis (this includes
             protective earth which is usually derived from
             the station's main supply).

         d)  All electrical interconnections for data between
             the equipments will use low level keying systems,
             i.e. 6-0-6 volts at currents less than one milli-ampere.
             All the remaining control lines should conform
             to CCITT Recommendation V28.

             In special cases where a line current of more than
             one milli-ampere is felt necessary then the contractor
             must submit his specific proposal for approval
             by ACE COMSEC.

         e)  All electrical wiring on the red side shall be
             run in a screened cable, consisting of twisted
             pairs and an overall continuous n̲o̲n̲-̲f̲e̲r̲r̲o̲u̲s̲ ̲s̲c̲r̲e̲e̲n̲.

             When installed, the cable will carry classified
             information in telegraph and data form in the clear
             text and must have been approved for this purpose
             by the NATO Communications Security Authority.

             The cables must receive COMSEC approval before
             installation. Cable specifications and sample lengths
             of not less than three metres shall be supplied
             to A̲C̲E̲ ̲C̲O̲M̲S̲E̲C̲ for approval prior to installation.

             1)-7) below lists the specifications, which should
             be used for selection of the cable.

             1)  C̲a̲b̲l̲e̲

             The cable shall contain 12 stranded conductors
             in PVC insulated cores with a single collective
             copper braid screen and overall PVC insulation.



             It shall conform to the following parameters:

                 1)  Number of strands in each conductor 7
                 2)  Diameter of wires in core            0.2
                     mm nominal
                 3)  Thickness of core insulation         0.3
                     mm nominal
                 4)  Overall diameter of cable minimum    6.6
                     mm
                                               maximum    7.2
                     mm


                 5)  Capacitance, wire to wire, and each
                     wire to sheath                       50
                     pF/metre max.

             2)  C̲o̲n̲d̲u̲c̲t̲o̲r̲s̲

             There shall be no kinks, broken wires or other
             irregularities in the conductors.

             The PVC insulation is to be extruded on to the
             conductors.

             3)  S̲c̲r̲e̲e̲n̲

                 The screen shall be of braided construction
                 and shall be formed of uniformly tinned copper
                 wires.

                 The screen shall be close fitting but it shall
                 be possible to slide back the screen by hand.

                 There shall be not more than one break in the
                 wires from any individual bobbin in any 25
                 mm length of cable.

                 There will be no joints in the complete braid.

                 The filling factor shall be not less than 0.7.

             4)  C̲o̲n̲s̲t̲r̲u̲c̲t̲i̲o̲n̲

                 A polyester film not thicker than 0.025 mm
                 shall be applied over the laid up cores in
                 such a manner that each turn of the tape shall
                 overlap the preceding turn by at least 15%.

                 Successive layers of cores shall be laid up
                 in the same direction with the layer short
                 enough to ensure reasonable flexibility to
                 the cable.

                 PVC filling may be used to assist in obtaining
                 a circular formation to the cable.

                 Overall insulation shall be of black PVC and
                 be free from inclusion and extrusion defects.

                 The sheath shall be easily removable from the
                 other component parts of the cable.

                 Colour coding shall be used for identification
                 of conductors.


             5)  E̲n̲v̲i̲r̲o̲n̲m̲e̲n̲t̲a̲l̲

                 The cable shall meet the following environmental
                 conditions:

                     Installation and operation:   0 C to 40
                     C, RH 10% - 88%
                     Storage and transportation: -30 C to 55
                     C, RH 10% - 98%

             6)  I̲n̲s̲u̲l̲a̲t̲i̲o̲n̲

                 The completed cable, in the dry state, shall
                 withstand for 1 min 1000 V rms. at 50 Hz applied
                 between all of the conductors connected together
                 and the screen.

             7)  P̲a̲c̲k̲a̲g̲i̲n̲g̲ ̲a̲n̲d̲ ̲M̲a̲r̲k̲i̲n̲g̲

                 The cable shall be delivered on disposable
                 drums.

                 Each drum shall carry 500 meters (+/-5%) of
                 cable in one piece and both ends of the cable
                 shall be suitably sealed to prevent the ingress
                 of moisture.

                 Each drum shall carry a printed label containing,
                 as a minimum, the following data:

                 1)  NATO Property
                 2)  12W cable. CAMPS project
                 3)  500 metres
                 4)  Date of manufacture (month and year)
                 5)  NATO stock number

         f)  Installation of optical fibers shall be in accordance
             with AMSG 719B.

         g)  As-built drawings and all circuit diagrams of the
             first operational system, and similar material
             for any variations in subsequent system to be delivered,
             showing all electrical interfaces and voltages,
             shall be supplied to ACE COMSEC before factory
             inspection.

         h)  To assist in the assessment of physical security
             and guarding of classified information, a list
             of all items of equipment which will store, display
             or record classified information shall be supplied
             to ACE COMSEC by the contractor, both local and
             remote. From the list, an assessment will be made
             for physical security in accordance with AMSG 293D.


         i)  Installation work will be witnessed by local COMSEC
             staff to ensure that all installation conforms
             to COMSEC requirements.

         j)  External traffic circuits connected to the central
             processor will normally be equipped with on-line
             synchronous cryptographic equipment to be supplied,
             installed and maintained by the purchaser.

         k)  The central processor will be installed in an area
             designated as a Red Area. Within the Red Area classified
             information may be handled in plain language; the
             transfer of information in an electrical form within
             this area shall be subject to and comply with the
             criteria laid down in AMSG 719B.

         l)  The crosstalk attenuation between any circuit carrying
             classified information and any other circuit within
             the installation shall be not less than 100 dB.

         m)  Send and receive data circuits and release pulse
             circuits shall be capable of producing or interpreting
             signals when the pulse shape is such that the rise
             and fall times, defined as the time required for
             the voltage to rise or fall to 80% of its peak-to-peak
             value, shall be within 5% to 15% of the unit interval
             at the applicable modulation rate. Transitions
             in both directions shall be approximately equal
             with these limits and be equally affected by shunt
             capacitance. Pulse forms shall exhibit smooth exponential
             curves and contain no points of inflexion during
             reversals.

         n)  On send circuits the pulse form shall be measured
             at the line tag blocks at the Patch Test and Monitor
             Facility. Limits shall be met at this reference
             plan with the circuits terminated with a 5000 and
             7000 ohm resistive load for the tests and repeated
             with an additional shunt capacitance of 2500 picofarads.

         o)  The power supply to all the equipment in the Red
             Area will enter via a filter or a group of filters
             which will be supplied by the purchaser. The function
             of these filters is to ensure that no compromising
             signals are able to reach a Black Area via the
             power supply leads. The equipment shall function
             satisfactorily with these filters present in the
             power leads.



         p)  The design of any maintenance facility shall incorporate
             suitable security features which as a minimum shall
             prevent:

             1)  B̲y̲p̲a̲s̲s̲i̲n̲g̲ ̲t̲h̲e̲ ̲E̲n̲c̲r̲y̲p̲t̲i̲o̲n̲ ̲D̲e̲v̲i̲c̲e̲

                 Any test procedure incorporating the bypassing
                 of the Data Encryption Devices and Isolators
                 shall include a positive hardware feature which
                 prevents the simultaneous bypassing of the
                 Panel Switching Equipment and the connection
                 of the DCE to an external telephone line.

             2)  I̲n̲a̲d̲v̲e̲r̲t̲e̲n̲t̲ ̲C̲o̲n̲n̲e̲c̲t̲i̲o̲n̲ ̲o̲f̲ ̲R̲e̲d̲ ̲a̲n̲d̲ ̲B̲l̲a̲c̲k̲ ̲W̲i̲r̲i̲n̲g̲

                 The test and patching facilities shall be designed
                 so that there is no possibility of inadvertently
                 connecting red and black wiring.



3.4.5.2  C̲o̲n̲t̲r̲o̲l̲ ̲o̲f̲ ̲R̲e̲c̲o̲r̲d̲ ̲O̲u̲t̲p̲u̲t̲

         To facilitate control, procedures shall be implemented
         which provide means for identification of:

         1)  Print out
         2)  Punched paper tapes
         3)  Removable storage media



3.4.5.2.1    P̲r̲i̲n̲t̲-̲O̲u̲t̲

         Print-out shall carry document control number as defined
         in section 3.2.3.7.2.



3.4.5.2.2    P̲u̲n̲c̲h̲e̲d̲ ̲P̲a̲p̲e̲r̲ ̲T̲a̲p̲e̲

         Messages punched out shall be preceeded by 20 cms blank
         tape and succeeded by 30 cms blank tape. A document
         control number shall be punched in front of the message
         punched out. (The number consists of 4 digits).





3.4.5.2.3    R̲e̲m̲o̲v̲a̲b̲l̲e̲ ̲s̲t̲o̲r̲a̲g̲e̲ ̲m̲e̲d̲i̲a̲

         a)  Units of removable storage such as a removable
             disk pack shall be controlled logically by the
             supervisor.

         b)  Logically controlled means that the supervisor
             shall have commands available to control the removable
             media after it has been physically mounted. Logically
             controlled is as opposed to physical control, which
             in principle can be performed by anyone having
             physical access to the diskdrive.

         c)  The following procedures are implemented (refer
             to supervisory functions, (section 3.2.4.  1.1.11).

             1)  Unit identification
             2)  Removal of previous stored information
             3)  Action on loading a unit for retrieval purposes
             4)  Unit directory
             5)  Display/print-out of stored information



3.4.5.3  A̲c̲c̲o̲u̲n̲t̲a̲b̲i̲l̲i̲t̲y̲ ̲o̲f̲ ̲T̲r̲a̲n̲s̲a̲c̲t̲i̲o̲n̲s̲

         Requirement related log and statistical information
         to be complied by the system are given in sections
         3.2.5 and 3.2.6 respectively.


3.4.5.4  S̲u̲p̲e̲r̲v̲i̲s̲o̲r̲y̲ ̲S̲e̲c̲u̲r̲i̲t̲y̲ ̲M̲o̲n̲i̲t̲o̲r̲i̲n̲g̲

         All requirements related to supervisory security monitoring
         are specified in detail in section 3.2.4.1.1.5.



3.4.5.5  T̲e̲r̲m̲i̲n̲a̲l̲ ̲A̲c̲c̲e̲s̲s̲ ̲C̲o̲n̲t̲r̲o̲l̲

         All requirements related to terminal access control
         are specified in detail in section 3.2.3.2.





3.4.5.6  S̲e̲c̲u̲r̲i̲t̲y̲ ̲C̲l̲a̲s̲s̲i̲f̲i̲c̲a̲t̲i̲o̲n̲ ̲a̲n̲d̲ ̲S̲p̲e̲c̲i̲a̲l̲ ̲H̲a̲n̲d̲l̲i̲n̲g̲

         The classification applicable to CAMPS are the NATO
         classifications specified below:

         -   COSMIC TOP SECRET
         -   NATO SECRET
         -   NATO CONFIDENTIEL
         -   NATO RESTRICTED
         -   NATO UNCLASSIFIED

         S̲p̲e̲c̲i̲a̲l̲ ̲H̲a̲n̲d̲l̲i̲n̲g̲

         The number of special handling designators shall be
         as specified in section 3.4.1.1.1.

         The following designators applies:


         S̲P̲E̲C̲I̲A̲L̲ ̲C̲A̲T̲E̲G̲O̲R̲Y̲ ̲W̲A̲R̲N̲I̲N̲G̲S̲           D̲E̲S̲I̲G̲N̲A̲T̲O̲R̲

         ATOMAL  ..............................  L
         EXCLUSIVE  ...........................  P
         CRYPTO SECURITY  .....................  Y
         DATA MESSAGE  ........................  D

         Other, e.g. for exercise traffic may be specified up
         to the maximum.



3.4.5.7  S̲y̲s̲t̲e̲m̲ ̲D̲e̲s̲i̲g̲n̲ ̲R̲e̲q̲u̲i̲r̲e̲m̲e̲n̲t̲s̲

         In this section requirements with respect to hardware
         and software aspects of equipment design are given.

         a)   H̲a̲r̲d̲w̲a̲r̲e̲

             1)  A clean architectural design where unassigned
                 codes must cause a trap.

             2)  Memory bound mechanisms shall exist. The MAP
                 module prevents programs from being able to
                 write in memory occupied by the operating system
                 or by other application programs.

                 Attempt to illegally access occupied data areas
                 shall give rise to a warning to the supervisor.



             3)  Two classes of instructions, one for the privileged
                 use of the operating system and a user mode
                 used by both operating system and application
                 programs  shall exist.

                 A set of privileged instructions exclusively
                 reserved for the operating system. These instructions
                 must control all I/O, the setting of memory
                 bounds mechanism, the setting of the system
                 state - privileged or user problem.

                 Sensitive instructions which could divert,
                 disrupt or inadvertently change the state of
                 the application software provided with CAMPS
                 shall not be available for execution unless
                 the processor is in a "privileged" state.

             4)  Every instruction code shall result in a prescribed
                 action. The occurence and/or attempted execution
                 of any illegal code or bit-pattern shall be
                 signalled and shall result in an abort procedure.

             5)  Key switches shall be provided on all VDU's
                 and medium speed teleprinters.

             6)  A read/write memory erase function feature
                 shall be provided. HW/SW techniques must be
                 available to the accomplishment of this function.

             7)  All hardware shall be individually addressable
                 by the computer.

         b)  S̲o̲f̲t̲w̲a̲r̲e̲

             The following software features shall be provided:

             1)  All programmes and data files loaded into the
                 system shall carry block parity check sums
                 to allow the detection of corrupted data.

             2)  Access to CAMPS data files shall be made through
                 system calls which pass through the authorisation
                 mechanism.

             3)  Recovery procedures after system failure shall
                 include checksumming of the operating system
                 software, reloading if this is necessary.



             4)  The supervisor shall have facilities to cause
                 a system integrity check (i.e. checksumming
                 of system software) to be performed at any
                 time he sees fit. This shall be done without
                 disrupting the functioning of the system.

             5)  To the extent possible, the operating system
                 shall run in the non-privileged user state.