ADAPTOR CRATES FOR CU AND WDPU
…02……02…CAMPS
1. I̲N̲T̲R̲O̲D̲U̲C̲T̲I̲O̲N̲
In this ECP, it is proposed to change the design of:
a) The DATA EXCHANGE CHANNEL (DEC), category 4 and
5. Current design is described in CPS/SDS/001,
section 5.3.2.4 and 5.3.2.5.
b) The channels for the VDU and LINE PRINTER of the
operator position. Current design is described
in CPS/SDS/001, section 5.4.
The changed configurations are shown on fig. 1 and
2.
In the changed design, the same TDX/ADAPTER CRATE is
used for mounting of Adapters/OPTO TRANCEIVERS throughout
CAMPS (including CAMPS REMOTE TERMINALS).
Until this change, the V24/V28(L) - adapter has been
a 4-channel module (see fig. 4) supporting 4 low/medium
speed channels each containing 5 CCITT, V24 circuits.
In order to support the high speed channels of DEC
4 and 5, a new version (Version 2) has been defined.
Thus, 2 V24/V28(L) adapter modules are included in
the changed configuration:
a) V24/V28(L) Adapter 1 - module (4 channels)
b) V24/V28(L) Adapter 2 - module (1 channel)
The V24/V28(L) Adapter 2 module supports one high
speed channel containing 11 CCITT, V24 circuits.
The Figs. 5 and 6 show the possible combinations of
configuration of the TDS/ADAPTER CRATE using the Opto
tranceiver modules and the V24/V28(L) Adapter 1 and
2 modules.
2. P̲R̲I̲C̲E̲ ̲Q̲U̲O̲T̲A̲T̲I̲O̲N̲
The ECP 11 is a non cost ECP.
2.1 O̲V̲E̲R̲A̲L̲L̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲
Not applicable.
2.2 S̲I̲T̲E̲ ̲R̲E̲L̲A̲T̲E̲D̲ ̲C̲O̲S̲T̲S̲
Not applicable.
2.3 C̲U̲R̲R̲E̲N̲T̲ ̲B̲A̲S̲E̲L̲I̲N̲E̲ ̲C̲O̲S̲T̲
Not applicable.
3. S̲C̲H̲E̲D̲U̲L̲E̲ ̲I̲M̲P̲A̲C̲T̲
If the ECP is accepted prior to 810701, no schedule
impact is expected.
4. B̲I̲D̲D̲I̲N̲G̲ ̲P̲R̲O̲V̲I̲S̲I̲O̲N̲S̲
Not applicable (non-cost ECP).
4.1 V̲A̲L̲I̲D̲I̲T̲Y̲
Not applicable.
4.2 D̲E̲L̲I̲V̲E̲R̲Y̲
The changed configurations will be included in and
delivered with each Main Site Equipment.
4.3 A̲C̲C̲E̲P̲T̲A̲N̲C̲E̲ ̲C̲R̲I̲T̲E̲R̲I̲A̲
Will be included in Main CAMPS acceptance as described
in CAMPS SRS, CPS/210/SYS/0001 and CAMPS ACCEPTANCE
PLAN, CPS/PLN/012.
4.4 T̲Y̲P̲E̲ ̲O̲F̲ ̲P̲R̲O̲P̲O̲S̲A̲L̲
Non cost ECP.
4.5 P̲A̲Y̲M̲E̲N̲T̲ ̲P̲L̲A̲N̲
Not applicable.
4.6 P̲R̲O̲T̲E̲C̲T̲I̲O̲N̲ ̲A̲G̲A̲I̲N̲S̲T̲ ̲C̲U̲R̲R̲E̲N̲C̲Y̲ ̲F̲L̲U̲C̲T̲U̲A̲T̲I̲O̲N̲ ̲
Not applicable.
5. E̲N̲G̲I̲N̲E̲E̲R̲I̲N̲G̲ ̲C̲H̲A̲N̲G̲E̲ ̲D̲E̲S̲C̲R̲I̲P̲T̲I̲O̲N̲
See section 1 for general description of the proposed
change.
5.1 P̲R̲O̲P̲O̲S̲E̲D̲ ̲C̲O̲N̲F̲I̲G̲U̲R̲A̲T̲I̲O̲N̲
5.1.1 D̲a̲t̲a̲ ̲E̲x̲c̲h̲a̲n̲g̲e̲ ̲C̲h̲a̲n̲n̲e̲l̲ ̲(̲D̲E̲C̲)̲,̲ ̲C̲a̲t̲e̲g̲o̲r̲y̲ ̲4̲ ̲a̲n̲d̲ ̲5̲
Fig. 1 shows the proposed configuration of the DECs,
cat. 4 and 5 of each CAMPS MAIN SITE Equipment. The
channels included are the equipped channels of each
site, i.e. the channels where the LTUs are mounted.
5.1.1.1 L̲I̲A̲-̲N̲
The LIA-N module is a D-rear crate module carrying
V24 standard connectors on the front panel (accessed
at the rear end of the crate).
5.1.1.2 A̲d̲a̲p̲t̲e̲r̲ ̲C̲r̲a̲t̲e̲
The Adapter crate is identical with the TDX Crate.
One crate supports up to 8 channels. Fig. 3 shows
the principle. The BACK PANEL is mounted at the rear
side of the crate and is connected to the Motherboard
of the crate in the same position as the LTUX-S-module,
but from the rear. The LTUX-S-module is not mounted
in this application. Three different modules are possible
in the adapter positions.
a) V̲2̲4̲/̲V̲2̲8̲(̲L̲)̲ ̲A̲d̲a̲p̲t̲e̲r̲ ̲1̲.̲
This module is not included in the configuration
shown on fig. 1. The module is used for Low/Medium
speed channels supported by the LTUX-S's.
Characteristics:
1) Number of channels per module: 4
2) Circuits per channel (CCITT V24):
102 Signal Ground
103 Transmitted Data
104 Received Data
107 Data Set Ready
108/2 Data Terminal Ready
3) Waveshaping: The circuits (except circuit
102) are waveshaped for 1200 6ps.
4) Mechanical Dimensions:
Height: 221.5 mm (5u)
Width: 34.2 mm (2m)
Length: 305.0 mm
5) Front Panel:
4 V24 connectors, 1 per channel are placed
on the front panel for connection of external
cables.
b) V̲2̲4̲/̲V̲2̲8̲(̲L̲)̲ ̲A̲d̲a̲p̲t̲e̲r̲ ̲2̲
This module is new, defined for this changed configuration.
One module will be mounted per equipped LTU channel.
Characteristics:
1) Number of channels per module: 1.
2) Circuits per channel (CCITT V24):
102 Signal Ground
103 Transmitted data
104 Received Data
105 Request to send
106 Clear to send
107 Data set ready
108/2 Data terminal ready
109 Carrier detect
113/114 Transmitter clock
115 Receiver Clock
3) Waveshaping: The circuits (except circuit
102) are waveshaped for 9600 bps.
4) Mechanical dimensions:
Height: 221.5 mm (5u)
Width: 17.1 mm (1m)
Length: 305.0 mm
5) Front Panel:
1 V24 connector is placed on the front panel
for connection of external cable.
c) O̲p̲t̲o̲ ̲T̲r̲a̲n̲s̲c̲e̲i̲v̲e̲r̲ ̲(̲O̲M̲D̲T̲)̲
This module is not included in the configuration
shown on fig. 1.
Characteristics:
1) Number of channels per module: 1.
2) Mechanical Dimensions:
Height: 221.5 mm (5u)
Width: 17.1 mm (1m)
Length: 305.0 mm
3) Front Panel:
Two fibre-optic connectors are placed on the
front panel for connection of one (dual) fibre-optic
cable.
The V24/V28(L) Adapter converts the standard CCITT
V24/V28 signal levels to low level V24/V28 (V24/V28(L))
signals and vice versa. These low level signals conform
CPS/210/SYS/0001 paragraph 3.4.5.1.
The V24/V28(L) Adapter is a standard CR80S module.
The front panel holds CANNON plugs for connecting
cables between the module and the V24 Filter Assy.
A cable length per channel of approx. 15 m. (50 ft)
can be driven by the adapter modules.
Figs. 4, 5 and 6 show the possible combinations of
the adapters.
As shown on fig. 3, a separate Adapter Power Supply
is mounted for supplying power to the adapters.
5.1.2 O̲p̲e̲r̲a̲t̲o̲r̲ ̲P̲o̲s̲i̲t̲i̲o̲n̲ ̲I̲n̲t̲e̲r̲c̲o̲n̲n̲e̲c̲t̲i̲o̲n̲
Fig. 2 shows the proposed configuration of the interconnections
from the Watchdog PU to the operator position terminals.
The proposed configuration includes, that 2 channels
of the Adapter crate (section 5.1.1.2) are used for
interconnection to the operator VDU/LINE PRINTER.
The two terminals are connected by opto-links.
5.1.3 R̲a̲c̲k̲ ̲C̲o̲n̲f̲i̲g̲u̲r̲a̲t̲i̲o̲n̲
Fig. 8 shows the proposed configuration.
The crates identified on fig. 1 and 2 are placed in
rack B and C.
5.2 C̲U̲R̲R̲E̲N̲T̲ ̲C̲O̲N̲F̲I̲G̲U̲R̲A̲T̲I̲O̲N̲
5.2.1 D̲E̲C̲,̲ ̲C̲a̲t̲e̲g̲o̲r̲y̲ ̲4̲ ̲a̲n̲d̲ ̲5̲
Fig. 9 shows the current configuration.
5.2.2 O̲p̲e̲r̲a̲t̲o̲r̲ ̲P̲o̲s̲i̲t̲i̲o̲n̲ ̲I̲n̲t̲e̲r̲c̲o̲n̲n̲e̲c̲t̲i̲o̲n̲
Fig. 10 shows the current configuration.
5.3 D̲E̲S̲C̲R̲I̲P̲T̲I̲O̲N̲ ̲O̲F̲ ̲C̲H̲A̲N̲G̲E̲
5.3.1 P̲r̲o̲p̲o̲s̲e̲d̲ ̲A̲d̲d̲i̲t̲i̲o̲n̲a̲l̲ ̲I̲t̲e̲m̲s̲ ̲p̲e̲r̲ ̲M̲a̲i̲n̲ ̲S̲i̲t̲e̲
The following list includes the items added per main
site due to the proposed change.
I̲t̲e̲m̲ N̲u̲m̲b̲e̲r̲
a) LIA-N CR8082D/010--/00 Note 1
b) CRATE CR1053-/000--/00 1
c) BACK PANEL 2
d) ADAPTER POWER SUPPLY 1
e) V24/V28(L) ADAPTER 1 0
f) V24/V28(L) ADAPTER 2 Note 2
g) OPTO TRANCEIVER 2
h) CABLE, CU to Adapter Crate Note 2
i) Cable, Adapter crate to
Filter Box Note 2
j) Cable, WDPU to Adapter Crate 2
k) OPTO CABLE, Adapter Crate
to Oper. pos. 2
Notes:
1) The number of LIA-N modules equals the number of
LIA-L modules per site shown in CPS/SDS/001, fig.
4.1.1.2-5, i.e.:
a) one per CCIS channel
b) one per SCARS channel
c) one per 2 TARE channels
2) The number is equal to the number of high-speed
channels per site, i.e.:
a) one per CCIS channel
b) one per SCARS channel
c) one per TARE channel
5.3.2 I̲t̲e̲m̲ ̲R̲e̲d̲u̲c̲t̲i̲o̲n̲ ̲p̲e̲r̲ ̲M̲a̲i̲n̲ ̲S̲i̲t̲e̲
The following list includes the items left out per
site due to the proposed change.
I̲t̲e̲m̲ N̲u̲m̲b̲e̲r̲
a) LIA-L Note 1
b) Cable CU to filter box Note 2
c) Cable, WDPU to filter box 2
d) Cable, filter box to oper.
pos. 2
Notes 1 and 2: See notes 1 and 2, sect. 5.3.1.
5.4 O̲T̲H̲E̲R̲ ̲A̲F̲F̲E̲C̲T̲E̲D̲ ̲A̲R̲E̲A̲S̲
5.4.1 T̲r̲a̲n̲s̲p̲o̲r̲t̲a̲t̲i̲o̲n̲
Not applicable.
5.4.2 I̲n̲s̲t̲a̲l̲l̲a̲t̲i̲o̲n̲
5.4.2.1 A̲d̲v̲a̲n̲t̲a̲g̲e̲s̲ ̲D̲u̲e̲ ̲t̲o̲ ̲t̲h̲e̲ ̲P̲r̲o̲p̲o̲s̲e̲d̲ ̲C̲h̲a̲n̲g̲e̲
a) Installation of maintenance position terminals
is made identical to other connected terminals
(VDUs, Printers).
b) Grounding of CAMPS MAIN SITE Equipment, including
operator position equipment, is made less critical
due to the opto-link connection.
5.4.3 M̲a̲i̲n̲t̲e̲n̲a̲n̲c̲e̲
The proposed change improves the maintenance concept
due to:
a) the general adapter concept used for all external
channels.
b) the same V24/V28 monitor is used for all channels.
5.4.4 S̲p̲a̲r̲e̲s̲
a) Two new items are defined. Sect. 5.3.1, item a),
f).
b) One item is removed: Sect. 5.3.2, item a).
c) The cost of the set of items of a) above balances
approximately the cost of the item of b) above,
i.e. a minor change in the spare part cost is expected.
5.4.5 T̲r̲a̲i̲n̲i̲n̲g̲
Not applicable.
6. R̲E̲C̲O̲M̲M̲E̲N̲D̲A̲T̲I̲O̲N̲