⟦5531db58b⟧ Wang Wps File

    Length: 9341 (0x247d)
    Types: Wang Wps File
    Notes: CPS/ECP/011               
    Names: »1077A «

Derivation

└─⟦af7ebed0d⟧ Bits:30006042 8" Wang WCS floppy, CR 0067A
    └─ ⟦this⟧ »1077A « 

WangText





…02…CPS/ECP/011

…02…BHB/810623…02……02…#
ADAPTOR CRATES FOR CU AND WDPU
…02……02…CAMPS







1.       I̲N̲T̲R̲O̲D̲U̲C̲T̲I̲O̲N̲

         In this ECP, it is proposed to change the design of:

         a)  The DATA EXCHANGE CHANNEL (DEC), category 4 and
             5.  Current design is described in CPS/SDS/001,
             section 5.3.2.4 and 5.3.2.5.

         b)  The channels for the VDU and LINE PRINTER of the
             operator position.  Current design is described
             in CPS/SDS/001, section 5.4.

         The changed configurations are shown on fig. 1 and
         2.

         In the changed design, the same TDX/ADAPTER CRATE is
         used for mounting of Adapters/OPTO TRANCEIVERS throughout
         CAMPS (including CAMPS REMOTE TERMINALS).

         Until this change, the V24/V28(L) - adapter has been
         a 4-channel module (see fig. 4) supporting 4 low/medium
         speed channels each containing 5 CCITT, V24 circuits.

         In order to support the high speed channels of DEC
         4 and 5, a new version (Version 2) has been defined.
          Thus, 2 V24/V28(L) adapter modules are included in
         the changed configuration:

         a)  V24/V28(L) Adapter 1 - module (4 channels)

         b)  V24/V28(L) Adapter 2 - module (1 channel)

         The V24/V28(L) Adapter 2 module supports  one high
         speed channel containing 11 CCITT, V24 circuits.

         The Figs. 5 and 6 show the possible combinations of
         configuration of the TDS/ADAPTER CRATE using the Opto
         tranceiver modules and the V24/V28(L) Adapter 1 and
         2 modules.



2.       P̲R̲I̲C̲E̲ ̲Q̲U̲O̲T̲A̲T̲I̲O̲N̲

         The ECP 11 is a non cost ECP.



2.1      O̲V̲E̲R̲A̲L̲L̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲

         Not applicable.



2.2      S̲I̲T̲E̲ ̲R̲E̲L̲A̲T̲E̲D̲ ̲C̲O̲S̲T̲S̲

         Not applicable.



2.3      C̲U̲R̲R̲E̲N̲T̲ ̲B̲A̲S̲E̲L̲I̲N̲E̲ ̲C̲O̲S̲T̲

         Not applicable.



3.       S̲C̲H̲E̲D̲U̲L̲E̲ ̲I̲M̲P̲A̲C̲T̲

         If the ECP is accepted prior to 810701, no schedule
         impact is expected.





4.       B̲I̲D̲D̲I̲N̲G̲ ̲P̲R̲O̲V̲I̲S̲I̲O̲N̲S̲

         Not applicable (non-cost ECP).



4.1      V̲A̲L̲I̲D̲I̲T̲Y̲

         Not applicable.



4.2      D̲E̲L̲I̲V̲E̲R̲Y̲

         The changed configurations will be included in and
         delivered with each Main Site Equipment.


4.3      A̲C̲C̲E̲P̲T̲A̲N̲C̲E̲ ̲C̲R̲I̲T̲E̲R̲I̲A̲

         Will be included in Main CAMPS acceptance as described
         in CAMPS SRS, CPS/210/SYS/0001 and CAMPS ACCEPTANCE
         PLAN, CPS/PLN/012.



4.4      T̲Y̲P̲E̲ ̲O̲F̲ ̲P̲R̲O̲P̲O̲S̲A̲L̲

         Non cost ECP.



4.5      P̲A̲Y̲M̲E̲N̲T̲ ̲P̲L̲A̲N̲

         Not applicable.



4.6      P̲R̲O̲T̲E̲C̲T̲I̲O̲N̲ ̲A̲G̲A̲I̲N̲S̲T̲ ̲C̲U̲R̲R̲E̲N̲C̲Y̲ ̲F̲L̲U̲C̲T̲U̲A̲T̲I̲O̲N̲ ̲

         Not applicable.





5.       E̲N̲G̲I̲N̲E̲E̲R̲I̲N̲G̲ ̲C̲H̲A̲N̲G̲E̲ ̲D̲E̲S̲C̲R̲I̲P̲T̲I̲O̲N̲

         See section 1 for general description of the proposed
         change.



5.1      P̲R̲O̲P̲O̲S̲E̲D̲ ̲C̲O̲N̲F̲I̲G̲U̲R̲A̲T̲I̲O̲N̲



5.1.1    D̲a̲t̲a̲ ̲E̲x̲c̲h̲a̲n̲g̲e̲ ̲C̲h̲a̲n̲n̲e̲l̲ ̲(̲D̲E̲C̲)̲,̲ ̲C̲a̲t̲e̲g̲o̲r̲y̲ ̲4̲ ̲a̲n̲d̲ ̲5̲

         Fig. 1 shows the proposed configuration of the DECs,
         cat. 4 and 5 of each CAMPS MAIN SITE Equipment.  The
         channels included are the equipped channels of each
         site, i.e. the channels where the LTUs are mounted.





5.1.1.1  L̲I̲A̲-̲N̲

         The LIA-N module is a D-rear crate module carrying
         V24 standard connectors on the front panel (accessed
         at the rear end of the crate).



5.1.1.2  A̲d̲a̲p̲t̲e̲r̲ ̲C̲r̲a̲t̲e̲

         The Adapter crate is identical with the TDX Crate.
          One crate supports up to 8 channels.  Fig. 3 shows
         the principle.  The BACK PANEL is mounted at the rear
         side of the crate and is connected to the Motherboard
         of the crate in the same position as the LTUX-S-module,
         but from the rear.  The LTUX-S-module is not mounted
         in this application.  Three different modules are possible
         in the adapter positions.

         a)  V̲2̲4̲/̲V̲2̲8̲(̲L̲)̲ ̲A̲d̲a̲p̲t̲e̲r̲ ̲1̲.̲

             This module is not included in the configuration
             shown on fig. 1.  The module is used for Low/Medium
             speed channels supported by the LTUX-S's.

             Characteristics:

             1)  Number of channels per module:  4

             2)  Circuits per channel (CCITT V24):

                 102 Signal Ground
                 103 Transmitted Data
                 104 Received Data
                 107 Data Set Ready
                 108/2 Data Terminal Ready

             3)  Waveshaping:  The circuits (except circuit
                 102) are waveshaped for 1200 6ps.

             4)  Mechanical Dimensions:

                 Height:  221.5 mm (5u)
                 Width:    34.2 mm (2m)
                 Length:  305.0 mm



             5)  Front Panel:

                 4 V24 connectors, 1 per channel are placed
                 on the front panel for connection of external
                 cables.

         b)  V̲2̲4̲/̲V̲2̲8̲(̲L̲)̲ ̲A̲d̲a̲p̲t̲e̲r̲ ̲2̲

             This module is new, defined for this changed configuration.
              One module will be mounted per equipped LTU channel.

             Characteristics:

             1)  Number of channels per module:  1.

             2)  Circuits per channel (CCITT V24):

                 102  Signal Ground
                 103  Transmitted data
                 104  Received Data
                 105  Request to send
                 106  Clear to send
                 107  Data set ready
                 108/2 Data terminal ready
                 109  Carrier detect
                 113/114  Transmitter clock
                 115  Receiver Clock

             3)  Waveshaping:  The circuits (except circuit
                 102) are waveshaped for 9600 bps.

             4)  Mechanical dimensions:

                 Height:  221.5 mm (5u)
                 Width:    17.1 mm (1m)
                 Length:  305.0 mm

             5)  Front Panel:

                 1 V24 connector is placed on the front panel
                 for connection of external cable.



         c)  O̲p̲t̲o̲ ̲T̲r̲a̲n̲s̲c̲e̲i̲v̲e̲r̲ ̲(̲O̲M̲D̲T̲)̲

             This module is not included in the configuration
             shown on fig. 1.

             Characteristics:

             1)  Number of channels per module:  1.

             2)  Mechanical Dimensions:

                 Height:  221.5 mm (5u)
                 Width:    17.1 mm (1m)
                 Length:  305.0 mm

             3)  Front Panel:

                 Two fibre-optic connectors are placed on the
                 front panel for connection of one (dual) fibre-optic
                 cable.

         The V24/V28(L) Adapter converts the standard CCITT
         V24/V28 signal levels to low level V24/V28 (V24/V28(L))
         signals and vice versa.  These low level signals conform
         CPS/210/SYS/0001 paragraph 3.4.5.1.

         The V24/V28(L) Adapter is a standard CR80S module.
          The front panel holds CANNON plugs for connecting
         cables between the module and the V24 Filter Assy.

         A cable length per channel of approx. 15 m. (50 ft)
         can be driven by the adapter modules.

         Figs. 4, 5 and 6 show the possible combinations of
         the adapters.

         As shown on fig. 3, a separate Adapter Power Supply
         is mounted for supplying power to the adapters.



5.1.2    O̲p̲e̲r̲a̲t̲o̲r̲ ̲P̲o̲s̲i̲t̲i̲o̲n̲ ̲I̲n̲t̲e̲r̲c̲o̲n̲n̲e̲c̲t̲i̲o̲n̲

         Fig. 2 shows the proposed configuration of the interconnections
         from the Watchdog PU to the operator position terminals.



         The proposed configuration includes, that 2 channels
         of the Adapter crate (section 5.1.1.2) are used for
         interconnection to the operator VDU/LINE PRINTER. 
         The two terminals are connected by opto-links.



5.1.3    R̲a̲c̲k̲ ̲C̲o̲n̲f̲i̲g̲u̲r̲a̲t̲i̲o̲n̲

         Fig. 8 shows the proposed configuration.

         The crates identified on fig. 1 and 2 are placed in
         rack B and C.



5.2      C̲U̲R̲R̲E̲N̲T̲ ̲C̲O̲N̲F̲I̲G̲U̲R̲A̲T̲I̲O̲N̲



5.2.1    D̲E̲C̲,̲ ̲C̲a̲t̲e̲g̲o̲r̲y̲ ̲4̲ ̲a̲n̲d̲ ̲5̲

         Fig. 9 shows the current configuration.



5.2.2    O̲p̲e̲r̲a̲t̲o̲r̲ ̲P̲o̲s̲i̲t̲i̲o̲n̲ ̲I̲n̲t̲e̲r̲c̲o̲n̲n̲e̲c̲t̲i̲o̲n̲

         Fig. 10 shows the current configuration.



5.3      D̲E̲S̲C̲R̲I̲P̲T̲I̲O̲N̲ ̲O̲F̲ ̲C̲H̲A̲N̲G̲E̲



5.3.1    P̲r̲o̲p̲o̲s̲e̲d̲ ̲A̲d̲d̲i̲t̲i̲o̲n̲a̲l̲ ̲I̲t̲e̲m̲s̲ ̲p̲e̲r̲ ̲M̲a̲i̲n̲ ̲S̲i̲t̲e̲

         The following list includes the items added per main
         site due to the proposed change.




         I̲t̲e̲m̲                               N̲u̲m̲b̲e̲r̲

         a)  LIA-N CR8082D/010--/00         Note 1
         b)  CRATE CR1053-/000--/00           1
         c)  BACK PANEL                       2
         d)  ADAPTER POWER SUPPLY             1
         e)  V24/V28(L) ADAPTER 1             0
         f)  V24/V28(L) ADAPTER 2           Note 2
         g)  OPTO TRANCEIVER                  2
         h)  CABLE, CU to Adapter Crate     Note 2
         i)  Cable, Adapter crate to 
             Filter Box                     Note 2
         j)  Cable, WDPU to Adapter Crate     2
         k)  OPTO CABLE, Adapter Crate
             to Oper. pos.                    2

         Notes:

         1)  The number of LIA-N modules equals the number of
             LIA-L modules per site shown in CPS/SDS/001, fig.
             4.1.1.2-5, i.e.:

             a)  one per CCIS channel
             b)  one per SCARS channel
             c)  one per 2 TARE channels

         2)  The number is equal to the number of high-speed
             channels per site, i.e.:

             a)  one per CCIS channel
             b)  one per SCARS channel
             c)  one per TARE channel



5.3.2    I̲t̲e̲m̲ ̲R̲e̲d̲u̲c̲t̲i̲o̲n̲ ̲p̲e̲r̲ ̲M̲a̲i̲n̲ ̲S̲i̲t̲e̲

         The following list includes the items left out per
         site due to the proposed change.

         I̲t̲e̲m̲                               N̲u̲m̲b̲e̲r̲

         a)  LIA-L                          Note 1
         b)  Cable CU to filter box         Note 2
         c)  Cable, WDPU to filter box        2
         d)  Cable, filter box to oper. 
             pos.                             2

         Notes 1 and 2:  See notes 1 and 2, sect. 5.3.1.


5.4      O̲T̲H̲E̲R̲ ̲A̲F̲F̲E̲C̲T̲E̲D̲ ̲A̲R̲E̲A̲S̲



5.4.1    T̲r̲a̲n̲s̲p̲o̲r̲t̲a̲t̲i̲o̲n̲

         Not applicable.



5.4.2    I̲n̲s̲t̲a̲l̲l̲a̲t̲i̲o̲n̲



5.4.2.1  A̲d̲v̲a̲n̲t̲a̲g̲e̲s̲ ̲D̲u̲e̲ ̲t̲o̲ ̲t̲h̲e̲ ̲P̲r̲o̲p̲o̲s̲e̲d̲ ̲C̲h̲a̲n̲g̲e̲

         a)  Installation of maintenance position terminals
             is made identical to other connected terminals
             (VDUs, Printers).

         b)  Grounding of CAMPS MAIN SITE Equipment, including
             operator position equipment, is made less critical
             due to the opto-link connection.



5.4.3    M̲a̲i̲n̲t̲e̲n̲a̲n̲c̲e̲

         The proposed change improves the maintenance concept
         due to:

         a)  the general adapter concept used for all external
             channels.

         b)  the same V24/V28 monitor is used for all channels.



5.4.4    S̲p̲a̲r̲e̲s̲

         a)  Two new items are defined.  Sect. 5.3.1, item a),
             f).

         b)  One item is removed:  Sect. 5.3.2, item a).

         c)  The cost of the set of items of a) above balances
             approximately the cost of the item of b) above,
             i.e. a minor change in the spare part cost is expected.


5.4.5    T̲r̲a̲i̲n̲i̲n̲g̲

         Not applicable.





6.       R̲E̲C̲O̲M̲M̲E̲N̲D̲A̲T̲I̲O̲N̲

         Not applicable.