WangText
…00……00……00……00……00…K…02……00……00…K
J…09…J…0a…J…00…J…05…J…07…I…09…I…0d…I…0e…I…01…I I…05…I…06…I…07…H…00…H…01…H…02…H
H H…05…E…08…E…0a…E…0b…E…0c……86…1 …02… …02… …02…
…02… CPS/TCN/037
…02… IJO/830309…02……02…#
CAMPS HARDWARE ASSEMBLY PROCEDURE
…02… ISSUE 2.1…02…CAMPS
T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲
0 FLW CHART ....................................
1
1 RACK ASSEMBLY .................................
2
2 SIGNAL CABELING COMPUTER RACKS ................
4
3 FILTER BOX ASSEMBLY ...........................
5
4 SIGNAL CABELING LIN TERMINATION RACKS ........
6
4.6 CABLES BETWEEN COMPUTER AND LINE TERM RACKS
6
4.7 CABLES BETWEEN LINE TERMINATION AND REMOTE
TERMINAL (MAIN SITE) RACKS ................
6
5 ADAPTOR CRATE ASSEMBLY ........................
8
6 TDX-CRATE ASSEMBLY ............................
9
CODING BP#1 ADAPTOR CRATE .....................
10
CODING BP#2 ADAPTOR CRATE .....................
11
CODING OF ADAPTOR CRATE MODULES ...............
12
7 FREQUENCY STBILIZER RACK ASSY ................
19
8 TARE RACK ASSEMBLY ............................
20
APPENDIX A ....................................
21
APPENDIX B ....................................
26
APPENDIX C .....................1̲6̲3̲6̲A̲…00…CPS/TCN/037
…00…vhn …00…IJO
…00…CPS H/W ASSY.BREAKDO…00…2̲9̲…00…0̲1̲…00…8̲2̲…00…1̲2̲…00…3̲9̲…00… ̲ ̲ ̲1̲…00…4̲2̲…00… ̲ ̲5̲4̲5̲9̲…00…28…00…03…00…83…00…10…00…33…00…
…00…01…00… 24…00…2̲8̲…00…0̲3̲…00…8̲3̲…00…1̲0̲…00…3̲5̲…00…28…00…03…00…83…00…10…00…36…00…0122A…00… 64…00… ̲ ̲1̲4̲…00…39…00… 368…00…
̲3̲2̲808…00……1c……00……01…`…00……06……00……95……00……01……10……06…'…10……11……02……90…*̲J̲…15……05……00……00……00……00……00……00……01…7
…9e……00……00……00……00……00……00…J…0a……00……00…J…0b…J…01…J…02…I…08…I…0d…I…0f…I…01…I…05…I…06…H…01…H H…05…H…06…H…07…E…08…E…09…E…0a…E…0b…E…0c…E…0d…E…00…E…02…E
E …86…1 …02…
…02… …02…
…02… CPS/TCN/037
…02… IJO/830309…02……02…#
CAMPS HARDWARE ASSEMBLY PROCEDURE
…02… ISSUE 2.1…02…CAMPS
T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲
0 FLW CHART ....................................
1
1 RACK ASSEMBLY .................................
2
2 SIGNAL CABELING COMPUTER RACKS ................
4
3 FILTER BOX ASSEMBLY ...........................
5
4 SIGNAL CABELING LIN TERMINATION RACKS ........
6
4.6 CABLES BETWEEN COMPUTER AND LINE TERM RACKS
6
4.7 CABLES BETWEEN LINE TERMINATION AND REMOTE
TERMINAL (MAIN SITE) RACKS ................
6
5 ADAPTOR CRATE ASSEMBLY ........................
8
6 TDX-CRATE ASSEMBLY ............................
9
CODING BP#1 ADAPTOR CRATE .....................
10
CODING BP#2 ADAPTOR CRATE .....................
11
CODING OF ADAPTOR CRATE MODULES ...............
12
7 FREQUENCY STBILIZER RACK ASSY ................
19
8 TARE RACK ASSEMBLY ............................
20
APPENDIX A ....................................
21
APPENDIX B ....................................
26
APPENDIX C ...................................
39…86…1 …02… …02… …02… …02…
FIGURE 0…01…ASSEMBLY PROCEDURE FLOW CHART…86…1 …02… …02… …02… …02…
1̲ ̲ ̲R̲A̲C̲K̲ ̲A̲S̲S̲E̲M̲B̲L̲Y̲
1.1 Dismount pallet and mount truck on each rack.
1.2 Add label with Site# and Rack #.
1.3 Join Rack A, B, and C respectively D, E, and F and
check that all 4 joiner bolts fit.
(The racks need not being bolted together during test,
except SYSTEM 0 and COMSEC SYSTEM).
1.4 Dismount front and rear doors.
(Check serial numbers in racks and doors).
1.4.1 Check/mount front panels with/without holes.
1. Mount the two foremost Panel Mounting Rails, ground
wires must be mounted in advance.
1.6 Mount mid and rear Panel Mounting Rails.
(Auxiliary tools for distance adjustments).
1.7 Mount ground wires. See H/W Assy: Fig. 2.1-21/3.1-17.
1.8 Mountclip-nuts on front Panel Mounting Rails.
(Auxiliary tools indicate placing in each rack).
1.9 Mount Mounting Rails. See H/W Assy: page 53 to 55
and 160 to 167.
1.10 Mount Supporting Rails
(start from bottom of each rack).
1.11 Mount Stretchig Slides for MMDs and SMD.
1.12 Mount Power Distribution Panels. See H/W Assy: Figure
2.1-2 and Figure 3.1-2.
1.13 Mount TDX Outlets. (Conf. H/W Assy. for site configuration)
See H/W Assy: page 36 and 142.
1.14 Mount Termostats and sensors. Se H/W Assy: page
51 and 158.
1.15 Mount Cable Tie Assembly.
1.15.1 Mount Cable Channels.…86…1 …02… …02… …02… …02…
1.16 Remove appropriate nock-outs (according to ILS ATBB
drawings).
1.16.1 Mount Power Line Filters.
(Conf. H/W Assy. Site no. - top/bottom entrance).
1.18 Mount TDX Bus cables See H/W. Assy: page 34 and
143 to 145.
1.19 Mount Mains Switch and connect ground wire. See H/W
Assy: page 56 and 168-169.
1.20 Mount PU, CU, and WDP Crates
Address switch settings: see Appendix C.
1.21 Mount M-Fan Units.
1.22 Mount S-Fan Uits.
Remove ground wire before mounting.
1.23 Mount Adaptor Crate (rack C).
Subassembly ref. 5 page 11.
1.24 Mount CTX Crates.
Subassembly ref. 6 page 12.
1.25 Mount Cable Channel Assemblies.
1.26 Mount Floppy Disk Unit.
1.27 Mount MMDs nd SMD and their locking mechanisms.
1.28 Mount Blind panels.
1.29 Draw Power cabeling:
See H/W Assy: Rack A,B,C page 66-67
Rack D,E,F page 208 to 223
1.30 Mount CCB Panels on CCB Cables. See H/W Assy: page
48 and147.…86…1 …02… …02… …02… …02…
2̲ ̲ ̲S̲I̲G̲N̲A̲L̲ ̲C̲A̲B̲E̲L̲I̲N̲G̲ ̲C̲O̲M̲P̲U̲T̲E̲R̲ ̲R̲A̲C̲K̲S̲
See H/W Assy. page 63 and 64.
2.1 Mount CCB Cable (W3)
2.2 Mount Data Cable #1 and #2 (W1,W2)
2.3 Mount WDCC Cables (W13, W14)
2.4 Mount isk and Floppy Cables (W6-12)
2.5 Mount V24 Cables on Adaptor Crate BP#1 and #2 (W21-28)
2.6 Mount TIA to X-Net Cables (W4-5, W15-16)
3̲ ̲ ̲F̲I̲L̲T̲E̲R̲ ̲B̲O̲X̲ ̲A̲S̲S̲E̲M̲B̲L̲Y̲
3.1 Assembly mechanical parts of Filter box according to
Atlantic Research Corp. Drwg.
3.2 Mount filtered V24 connectors according to site configuration
3.3 Add Site # (Label)
4̲ ̲ ̲S̲I̲G̲N̲A̲L̲ ̲C̲A̲B̲E̲L̲I̲N̲G̲ ̲L̲I̲N̲E̲ ̲T̲E̲R̲M̲I̲N̲A̲T̲I̲O̲N̲ ̲R̲A̲C̲K̲S̲
See H/W Assy. Page 175 to 190.
4.1 Mount Filter Box.
Subassembly ref. 3 page 8
4.2 Mount CCB Cable (W101)
4.3 Mount TDX to X-NetCable (W106, W107)
4.4 Mount BSM-X to X-Net Cables (W108-127). (Conf. H/W
Assy. for Site configuration)
4.5 Mount applicable V24 Cables according to Site configuration.
See H/W Assy. Page 191 to 207.
4.6 C̲a̲b̲l̲e̲s̲ ̲b̲e̲t̲w̲e̲e̲n̲ ̲C̲o̲m̲p̲u̲t̲e̲r̲-̲ ̲a̲n̲d̲ ̲L̲i̲n̲e̲ ̲T̲e̲r̲m̲.̲ ̲a̲c̲k̲s̲
These cables shall be withdrawn to rack D on disassembly.
Fig. 6.1-5 page 244.
4.6.1 Mount TDX Cables (W905-908)
4.6.2 Mount CCB Cable (W904)
4.6.3 Mount V24 Cables (W909-914)
Conf. H/W Assy. for Site configuration top/bottom entrance.
4.7 C̲a̲b̲l̲e̲s̲ ̲b̲e̲t̲w̲e̲e̲n̲ ̲L̲i̲n̲e̲ ̲T̲e̲r̲m̲i̲n̲a̲t̲i̲o̲n̲ ̲a̲n̲d̲ ̲R̲e̲m̲o̲t̲e̲ ̲T̲e̲r̲m̲i̲n̲a̲l̲
̲(̲M̲a̲i̲n̲ ̲S̲i̲t̲e̲)̲ ̲R̲a̲c̲k̲s̲
See H/W Assy.
4.7.1 Connect Power Cables (W336, W337)
4.7.2 Connect TDX Cables (W181-184)
4.7.3 Connect CCB Cable (W102)
4.7.4 Mount aplicable V24 Cables according to Site configuration.
See H/W Assy.
5̲ ̲ ̲A̲D̲A̲P̲T̲O̲R̲ ̲C̲R̲A̲T̲E̲ ̲A̲S̲S̲E̲M̲B̲L̲Y̲
See H/W Assy. page 44 and 45.
5.1 Add label with Site # and Pos. #
5.2 Dismount Main Power Panel.
CHANGE P/N LABEL TO 4.07004-02
5.3 Mount two Adptor Power Supplies
5.4.1 Code BP8#1 according to page 13
5.4.2 Code BP8#2 according to page 14
5.5 Mount Back Panel#1 and #2
5.6 Mount rear Blank Panels
5.7 Mount front Blank Panels
5.8 Code Opto T/R and L/L Adaptors according to drawings
pae 15 to 21.
5.9 Mount Opto T/R and L/L Adaptors
6̲ ̲ ̲T̲D̲X̲-̲C̲R̲A̲T̲E̲ ̲A̲S̲S̲E̲M̲B̲L̲Y̲
See H/W Assy. page 134 to 137.
6.1 Add label with Site # and Pos. #
6.2 Mount Adaptor Power Supply
6.3 Mount BSM-X Panel
Address switch settings, seeAppendix C.
6.4 Code and mark BP#1 and #2 if applicable. (Conf. H/W
Assy. for Crate configuration) coding according to
Appendix A.
6.5 Mount BP#1 and BP#2 if applicable
6.6 Mount BSM-X unit
6.7 If Crate #1 or #4:
Mount TDX Controller
Mount TX to BSM-X Cable
6.8 Mount LTUX-S#1 and #2
Address switch settings, see Appendix C.
6.9 Code Opto T/R and/or L/L Adaptors according to Crate
configuration.
Coding according to Appendix B.
CODING BP#1…01…ADAPTOR CRATE…86…1 …02… …02… …02… …02…
CODING BP#2…01…ADAPTOR CRATE…86…1 …02… …02… …02… …02…
W̲D̲P̲/̲V̲D̲U̲ ̲A̲N̲D̲ ̲M̲S̲P̲ ̲I̲N̲T̲E̲R̲F̲A̲C̲E̲
ADAPTOR CRATE
Fig. 2.5-1
L̲T̲U̲/̲S̲C̲A̲R̲S̲I̲I̲/̲A̲C̲C̲I̲S̲ ̲I̲N̲T̲E̲R̲F̲A̲C̲E̲
CUT STRAP
L̲T̲U̲/̲S̲C̲A̲R̲S̲I̲I̲/̲A̲C̲C̲I̲S̲ ̲I̲N̲T̲E̲R̲F̲A̲C̲E̲
Fig. 2.3-1
L̲T̲U̲/̲C̲O̲L̲L̲O̲C̲A̲T̲E̲D̲ ̲T̲A̲R̲E̲ ̲I̲N̲T̲E̲R̲F̲A̲C̲E̲
CUT STRAP
L̲T̲U̲/̲C̲O̲L̲L̲O̲C̲A̲T̲E̲D̲ ̲T̲A̲R̲E̲ ̲I̲N̲T̲E̲R̲F̲A̲C̲E̲
Fig. 2.4-1
L̲T̲U̲/̲R̲E̲M̲O̲T̲E̲ ̲T̲A̲R̲E̲ ̲I̲N̲T̲E̲R̲F̲A̲C̲E̲
CUT STRAP
L̲T̲U̲/̲R̲E̲M̲O̲T̲E̲ ̲T̲A̲R̲E̲ ̲I̲N̲T̲E̲R̲F̲A̲C̲E̲…86…1 …02… …02… …02… …02…
7̲ ̲ ̲F̲R̲E̲Q̲U̲E̲N̲C̲Y̲ ̲S̲T̲A̲B̲I̲L̲I̲Z̲E̲R̲ ̲R̲A̲C̲K̲ ̲A̲S̲S̲Y̲.̲
7.1 Mount nameplate on top front.
7.2 Mount ground wires (W511-513).
7.3 Mount Supporting Slides.
7.4 Mount clip-nuts on foremost Panel Mouting Rails.
7.5 Produce ground wires (W507-510).
7.6 Mount clip-nuts for ground wires.
7.7 Mount Supporting Rails.
7.8 Mount spacers (2 thin and 1 thick) on each side of
Frequency Stabilizer.
7.9 Add s/n label on front of Stabilizers, and By-pss Switch
Panel.
7.10 Mount By-pass Switch Panel.
7.11 Mount all three Stabilizers.
7.12 Mount ground wires (W507-510)
7.13 Mount power cables (W501-506)
7.14 Mount appropriate input-and output-cables.…86…1
…02… …02… …02… …02…
8̲ ̲ ̲T̲A̲R̲E̲ ̲R̲A̲C̲K̲ ̲A̲S̲S̲E̲M̲B̲L̲Y̲
8.1 Mount name plate on top front.
8.2 Mount ground wires (W614-616).
8.3 Mount Supporting Slides and Dual Modem Shelf.
8.4 Mount Power Distribution Panl and Power Inlet Box (including
W610).
8.5 Mount Mains Switch.
8.6 Mount V24 BPFJ and VF BPFJ.
8.7 Code Modem/s according to Appendix C.
8.8 Mount Modem/s.
8.9 Mount ground wires (W617-619).
8.10 Mount signal cables (W601-604).…86…1 …02… …02… …02… …02…
A P P E N D I X A…01…**********************…01……01…Coding of BP-8 panels.…01…(figure A-1 to A-4)…86…1 …02… …02… …02… …02…
CODING BP#1
OPTIONAL ADAPTORCRATE
Figure
A-1…86…1 …02… …02… …02… …02…
CODING BP #1 AND/OR #2
L̲T̲U̲X̲-̲S̲ ̲-̲ ̲S̲T̲A̲T̲.̲M̲U̲X̲.̲1̲
I̲N̲T̲E̲R̲F̲A̲C̲E̲
Figure
A-2…86…1 …02… …02… …02… …02…
CODING BP # 1
R̲E̲M̲O̲T̲E̲ ̲T̲E̲R̲M̲I̲N̲A̲L̲S̲ ̲S̲T̲A̲T̲M̲U̲X̲ ̲-̲ ̲O̲P̲T̲O̲ ̲T̲/̲R̲
I̲N̲T̲E̲R̲F̲A̲C̲E̲
Figure
A-3…86…1 …02… …02… …02… …02…
CODING BP # 2
R̲E̲M̲O̲T̲E̲ ̲T̲E̲R̲M̲I̲N̲A̲L̲S̲ ̲S̲T̲A̲T̲M̲U̲X̲ ̲-̲ ̲O̲C̲R̲ ̲A̲N̲D̲ ̲L̲S̲M̲
I̲N̲T̲E̲R̲F̲A̲C̲E̲
Figure
A-4…86…1 …02… …02… …02… …02…
A P P E N D I X B…01…**********************…01…Coding of CTX-Crate Modules…01…(Figure B-1 to B-12)…86…1 …02… …02… …02… …02…
…02…
L̲T̲U̲X̲-̲S̲-̲T̲R̲C̲/̲P̲O̲I̲N̲T̲ ̲T̲O̲ ̲P̲O̲I̲N̲T̲
I̲N̲T̲E̲R̲F̲A̲C̲E̲
Figure
B-1…86…1
…02…
…02…
…02…
…02…
…02…
CUT STRAP
REMOVE R51
IMPLEMENT ECO.635
L̲T̲U̲X̲-̲S̲-̲T̲R̲C̲/̲P̲O̲I̲N̲T̲ ̲T̲O̲ ̲P̲O̲I̲N̲T̲
I̲N̲T̲E̲R̲F̲A̲C̲E̲
Figure
-2…86…1
…02…
…02…
…02…
…02…
…02…
L̲T̲U̲X̲-̲S̲/̲O̲C̲R̲ ̲I̲N̲T̲E̲R̲F̲A̲C̲E̲
Figure
B-3…86…1
…02…
…02…
…02…
…02…
…02…
CUT STRAP
L̲T̲U̲X̲-̲S̲/̲O̲C̲R̲ ̲I̲N̲T̲E̲R̲F̲A̲C̲E̲
Figure
B-4…86…1
…02…
…02…
…02…
…02…
…02…
L̲T̲U̲X̲-̲S̲/̲P̲T̲P̲-̲P̲T̲R̲ ̲I̲N̲T̲E̲R̲F̲A̲C̲E̲
Figure
B-5
CUT STRAP
REMOVE R51
EMPLEMENT ECO.635
L̲T̲X̲-̲S̲/̲P̲T̲P̲-̲P̲T̲R̲ ̲I̲N̲T̲E̲R̲F̲A̲C̲E̲
Figure
B-6…86…1
…02… …02… …02… …02…
…02…
L̲T̲U̲X̲-̲S̲/̲V̲D̲U̲ ̲I̲N̲T̲E̲R̲F̲A̲C̲E̲
L̲T̲U̲X̲-̲S̲/̲M̲S̲P̲ ̲I̲N̲T̲E̲R̲F̲A̲C̲E̲
Figure
B-7…86…1
…02… …02… …02… …02…
…02…
L̲T̲U̲X̲-̲S̲/̲V̲D̲U̲ ̲I̲N̲T̲E̲R̲F̲A̲C̲E̲
L̲T̲U̲X̲-̲S̲/̲M̲S̲P̲ ̲I̲N̲T̲E̲R̲F̲A̲C̲E̲
Figure
B-8…86…1 …02… …02… …02… …02…
…02…
R̲E̲M̲O̲T̲E̲ ̲T̲E̲R̲M̲I̲N̲A̲L̲S̲
S̲T̲A̲T̲M̲U̲X̲ ̲-̲ ̲O̲C̲R̲ ̲I̲N̲T̲E̲R̲F̲A̲C̲E̲
Figure
B-9…86…1
…02… …02… …02… …02…
…02…
R̲E̲M̲O̲T̲E̲ ̲T̲E̲R̲M̲I̲N̲A̲L̲S̲
S̲T̲A̲T̲M̲U̲X̲ ̲-̲ ̲O̲C̲R̲ ̲I̲N̲T̲E̲R̲F̲A̲C̲E̲
Figure
B-10…86…1
…02… …02… …02… …02…
…02…
R̲E̲M̲O̲T̲E̲ ̲T̲E̲R̲M̲I̲N̲A̲L̲S̲
S̲T̲A̲T̲M̲U̲X̲ ̲-̲ ̲V̲D̲U̲/̲M̲S̲P̲ ̲I̲N̲T̲E̲R̲F̲A̲C̲E̲
(ELECTRIC)
Figure
B-11…86…1
…02… …02… …02… …02…
…02…
R̲E̲M̲O̲T̲E̲ ̲T̲E̲R̲M̲I̲N̲A̲L̲S̲
S̲T̲A̲T̲M̲U̲X̲ ̲-̲ ̲V̲D̲U̲/̲M̲S̲P̲ ̲I̲N̲T̲E̲R̲F̲A̲C̲E̲
(ELECTRIC)
Figure
B-12…86…1
…02… …02… …02… …02…
…02…
A P P E N D I X C
********************
…01…Addressswitch - and jumpersettings.
A̲D̲D̲R̲E̲S̲S̲S̲W̲I̲T̲C̲H̲-̲ ̲A̲N̲D̲ ̲J̲U̲M̲P̲E̲R̲S̲E̲T̲T̲I̲N̲G̲S̲
PROCESSOR UNIT
I̲T̲E̲M̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲C̲R̲ ̲N̲O̲.̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲S̲L̲O̲T̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲P̲A̲G̲E̲ ̲1̲6̲3̲6̲A̲…00…CPS/TCN/037 …00…vhn
…00…IJO …00…CPS H/W ASSY.BREAKDO…00…2̲9̲…00…0̲1̲…00…8̲2̲…00…1̲2̲…00…3̲9̲…00… ̲ ̲ ̲1̲…00…4̲2̲…00… ̲ ̲5̲4̲5̲9̲…00…14…00…12…00…83…00…09…00…06…00…
…00…03…00… 68…00…1̲4̲…00…1̲2̲…00…8̲3̲…00…0̲9̲…00…0̲9̲…00…20…00…12…00…83…00…13…00…46…00…0122A…00… 70…00… ̲ ̲1̲8̲…00…24…00… 464…00… ̲3̲6̲450…00……0e……00…
`…00……06……00……00……00……01……10……06…'…10……11……02……80…*̲J̲…15……05……00……00……00……00……00……00……01…7
8̲…00……18……00……00……00……00…C…0a……00……00…C…0b…C…01…C…02…B…08…B…0d…B…0f……1a……01……1a……05……1a……06……17……09……17……0c……17……0d……17……0e……17……0f……13……00……13……01……13……02……13…
…13… …13……05……12……08……12……0a……12……0b……12……0c……12……0d……12……0e……12……0f……86…1 …02… …02… …02…
…02… CPS/TCN/037
…02… IJO/831212…02……02…
CAMPS HARDWARE ASSEMBLY PROCEDURE
…02… ISSUE 3.2…02…CAMPS
T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲
0 FLW CHART ....................................
1
1 RACK ASSEMBLY .................................
2
2 SIGNAL CABELING COMPUTER RACKS ................
4
3 FILTER BOX ASSEMBLY ...........................
5
4 SIGNAL CABELING LIN TERMINATION RACKS ........
6
4.6 CABLES BETWEEN COMPUTER AND LINE TERM RACKS
6
4.7 CABLES BETWEEN LINE TERMINATION AND REMOTE
TERMINAL (MAIN SITE) RACKS ................
6
5 ADAPTOR CRATE ASSEMBLY ........................
8
6 TDX-CRATE ASSEMBLY ............................
9
CODING BP#1 ADAPTOR CRATE .....................
10
CODING BP#2 ADAPTOR CRATE .....................
11
CODING OF ADAPTOR CRATE MODULES ...............
12
7 FREQUENCY STBILIZER RACK ASSY ................
19
8 TARE RACK ASSEMBLY ............................
20
APPENDIX A ....................................
21
APPENDIX B ....................................
26
APPENDIX C .....................