CAMPS SITE LEVEL MAINTENANCE MANUAL
…02…Issue 1…02… CAMPS
 
 DISTRIBUTION EQUIPMENT TEST PROCEDURES STEP 5000 - 6000 (cont'd)

 STEP     PROCEDURE                     OBSERVATION/ACTION
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲





    2996A/rt  …02…CPS/TCM/005

…02…KJA/830912…02……02… 
CAMPS SITE LEVEL MAINTENANCE MANUAL
…02…Issue 1…02… CAMPS
 















4.3.3.5    D̲i̲s̲t̲r̲i̲b̲u̲t̲i̲o̲n̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲ ̲T̲e̲s̲t̲ ̲P̲r̲o̲c̲e̲d̲u̲r̲e̲s̲



    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * 
5000                      Distribution                              ENTRY
    Equipment Test



                          Before start of the Dist.Equip.
                          test procedure, verify that

                          1.The commands typed on the Maint.Pos.VDU
                          are directed to the PU which
                          should execute the test.

                          2.The PU is offline

                          3.The PU is enabled

                          4.The PU is in Normal Mode

                          It is possible to obtain these
                          conditions e̲i̲t̲h̲e̲r̲

                          a) by commands issued from the
                          Maint.Pos. VDU via the Watch
                          Dog Subsystem

                          o̲r̲

                          b) by manual switchs settings
                          on the MAP module and a reconfiguration
                          procedure.

                          a.1) P̲U̲ ̲ ̲ ̲M̲a̲i̲n̲t̲.̲P̲o̲s̲.̲V̲D̲U̲ ̲c̲o̲m̲m̲u̲n̲i̲c̲a̲t̲i̲o̲n̲
                               ̲b̲y̲ ̲t̲h̲e̲ ̲W̲D̲ ̲C̲o̲m̲m̲a̲n̲d̲

                               PUNno, no is no of the actual
                               PU (refer to section 5.76
                               in (*))

                          a.2) P̲U̲ ̲O̲F̲F̲L̲I̲N̲E̲ ̲B̲Y̲ ̲T̲H̲E̲ ̲W̲D̲ ̲c̲o̲m̲m̲a̲n̲d̲:̲

                               OFLI (refer to section 5.7.7
                               in (*))

                          a.3) P̲U̲ ̲e̲n̲a̲b̲l̲e̲d̲ ̲b̲y̲ ̲t̲h̲e̲ ̲W̲D̲ ̲c̲o̲m̲m̲a̲n̲d̲:̲
                               ̲E̲N̲P̲U̲
                               (refer to section 5.7.4
                               in (*)).

                          a.4) P̲U̲ ̲ ̲n̲o̲r̲m̲a̲l̲ ̲m̲o̲d̲e̲ ̲t̲h̲e̲ ̲W̲D̲ ̲c̲o̲m̲m̲a̲n̲d̲:̲
                               ̲N̲O̲R̲M̲
                               (refer to section 5.7.9
                               in (*))

                          (*) CAMPS MAINTENANCE POSITION
                          OPERATION MANUAL, Doc.No. CPS/OPM/005

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


                          b.1)   P̲U̲ ̲ ̲M̲a̲i̲n̲t̲.̲ ̲P̲o̲s̲.̲ ̲V̲D̲U̲ ̲c̲o̲m̲m̲u̲n̲i̲c̲a̲t̲i̲o̲n̲
                                 ̲b̲y̲ ̲r̲e̲c̲o̲n̲f̲i̲g̲u̲r̲a̲t̲i̲o̲n̲:̲

                                 It is possible to connect
                                 the Maint.Pos.VDU directly
                                 to the PU by a reconfiguration
                                 procedure. The procedure
                                 is described in step 3600
                                 - 3700 in section 4.3.3.3.

                          b.2)   P̲U̲ ̲O̲f̲f̲l̲i̲n̲e̲ ̲b̲y̲ ̲s̲w̲i̲t̲c̲h̲s̲e̲t̲t̲i̲n̲g̲

                                 The PU is taken offline
                                 by pressing the MC button
                                 situated on the front
                                 of the MAP module in the
                                 actual PU (refer to section
                                 4.5).

                          b.3)   P̲U̲ ̲e̲n̲a̲b̲l̲e̲d̲ ̲b̲y̲ ̲s̲w̲i̲t̲c̲h̲s̲e̲t̲t̲i̲n̲g̲.̲

                                 The PU is enabled by switching
                                 the EN/DIS switch on the
                                 front of the MAP module
                                 in the actual PU to the
                                 EN position (refer to
                                 section 4.5)

                          b.4)   P̲U̲ ̲ ̲N̲o̲r̲m̲ ̲M̲o̲d̲e̲ ̲b̲y̲ ̲S̲w̲i̲t̲c̲h̲s̲e̲t̲t̲i̲n̲g̲:̲

                                 The PU is set in normal
                                 mode by switching the
                                 MAIN/NRM switch on the
                                 front of the MAP module
                                 to the NRM position (refer
                                 to section 4.5)
 
    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


5005                      Analyze the error                        o If
                                                                     one
                                                                     or
                                                                     more
                                                                     of
                                                                     the
                                                                     following
                                                                     error
                                                                     reports
                                                                     are
                                                                     printed
                                                                     out
                                                                     on
                                                                     the
                                                                     maintenance
                                                                     position
                                                                     printer

                                 R̲e̲p̲o̲r̲t̲ ̲I̲D̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                 ̲ ̲ ̲ ̲ ̲ ̲

                                 TMS [14 - TMS [18
                                 PER [[1 - PER [[5
                                  ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                 ̲ ̲ ̲ ̲ ̲ ̲


                                    or

                            there is an error indication
                            in the distribution equipment
                            connected to the TDX system.

                                 GO TO step 5010



                          o If one or more of the following
                            error reports are printed on
                            the maintenance position printer

                                 R̲e̲p̲o̲r̲t̲ ̲I̲d̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                 ̲ ̲ ̲ ̲ ̲ ̲

                                 PER [[6 - PER [[8
                                  ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                 ̲ ̲ ̲ ̲ ̲ ̲


                                 or

                            there is an error indication
                            in the distribution equipment
                            connected to the LTU.


                                 GO TO step 5400.

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


5010                      Identify the                              The
                                                                    following
                                                                    options
                                                                    of
                                                                    distribution
    distribution            equipment are implemented:
    equipment connected
    to the LTUX-S         o L/L Adapter module

                                 GO TO step 5110

                          o OPTO Module

                                 GO TO step 5200

                          o Statistical Multiplexer and
                            Crypto equipment

                                 GO TO step 5300


    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *



    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

5100                      Error detected in                         ENTRY
    the L/L adaptor module
    or the peripheral

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

5105                      Boot the TDX ̲LOOP                        o The
                                                                     following
                                                                     output
                                                                     should
                                                                     appear
    test program.                                     
                                  
    A detailed step-by-         "CSS/730 CR 80 M
    step procedure is            TDX TEST VS..."
    described in section         "CPU ["              
                                    
    4.7.2.1.                     "--"
                                                 
    Below are listed                            
    the main steps in                   
    the procedure of                  
    the TDX ̲LOOP test.           

    Before entering the     If correct, continue to step
                            5110.
    boot command, verify
    that

    a) The actual DISK or FD
    CTRL is assigned to the
    Off-Line PU

    b) The actual disk
    pack or diskette is  
    mounted in the disk
    drive.

    The FD boot command is
    as follows:

    F̲D̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲         
    BA 1[[1 (CR)                   
    BU [ or 1 (CR)
    BT FD5[[ (CR)
    B̲E̲ ̲(̲C̲R̲)̲ ̲ ̲

    The Disk boot command
    is as follows:

    S̲M̲D̲ ̲D̲I̲S̲K̲ ̲ ̲ ̲ ̲ ̲ ̲
    BA 1[25 (CR)
    BM 14[ (CR)
    B̲E̲ ̲A̲ ̲(̲C̲R̲)̲
    …86…1    …02…                     …02… …02…    …02…  …02…                 
                
                          o If the expected output does
                            not appear then it indicates
                            that it is not possible to
                            boot the test program from
                            that floppy drive or disk drive.

                            Boot the TDX ̲LOOP test program
                            using the other drive.

                            If it is still not possible
                            to boot the test program, it
                            indicates an error in the communication
                            between the Channel Unit and
                            the Processor.

                                 GO TO step 2005.



    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


5110                      It is now possible to                    o Examine
                                                                     the
                                                                     output
                                                                     from
                                                                     the
                                                                     test
    start the TDX ̲LOOP      program in order to verify
                            if the
    test program.           program detected any errors.
    A detailed step-
    -by-step procedure      The error codes and an example
                            of a 
    is described in         successful print out
    section 4.7.2.1.        is shown in section 4.7.2.2.

    Below are listed the    The test time is app. 10 sec.
    main steps in the
    start procedure of      If correct, then there is no
                            error in
    the TDX ̲LOOP test.      the transmission to/from the
                               peripheral.

    Before entering the          Verify the Distribution
                                    
    start commend, verify        Equipment
    that                         GO TO step 5900      
                                             

    a) The parameter "no" 
    in the start command  
    is correct.           

    b) The BSM-X is assigned                          
                                     
    to the Off-line TDX                             
    Bus.

    c) The LTUX channel
    is enabled.

    d) The V24 Loop Back
    Adaptor is connected
    to the actual LTUX-Line
    connector in one of the
    test points shown 
    in figure 4.3.3.5-1.



    The start command is:

    DO TDX ̲LOOPno  (CR).



                          o If the test program detected
                            an error, then correct it or
                            replace the failing item. If
                            TDX crate error 
                                 GO TO step 4900. 

                            When the error is cleared

                                 Verify the Distribution
                                 Equipment

                                 GO TO step 5900
 
    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *
































              (1): V24 Loopback Adaptor +
                   V24 Monitoring Module

                   V24 Mon       Test of 
                   Module        Ch1-4
                   S̲l̲o̲t̲ ̲N̲o̲.̲ ̲ ̲ ̲ ̲ ̲ ̲S̲l̲o̲t̲ ̲N̲o̲.̲

                     5, 6         10-7
                    13, 14        18-15
                    ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲


                   NOTE:  The actual L/L Adaptor Channel Module must
                          be removed before running Loopback test
                          using V24 Monitoring Module and V24 Loopback
                          Adaptor

              (2)  V24 Loopback Adaptor



           Figure 4.3.3.5-1…01…L/L Adaptor Test Points


    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

5200                      Error detected in                         ENTRY
    the OPTO interface to
    a VDU/MSP

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


5205                      Boot the TDX ̲LOOP                        o The
                                                                     following
                                                                     output
                                                                     should
                                                                     appear
    test program.                                     
                                  
    A detailed step-by-          "CSS/730 CR 80 M
    step procedure is            TDX TEST VS..."
    described in section         "CPU ["              
                                    
    4.7.2.1.                     "---"
                                                 
    Below are listed        If correct, continue to step
                            5210
    the main steps in                   
    the procedure of                  
    the TDX ̲LOOP test.           

    Before entering the 
    boot command, verify
    that

    a) The actual DISK or FD
    CTRL assigned to the
    Off-Line PU

    b) The actual disk
    pack/diskette 
    is mounted 
    in the drive.

    The FD boot command is
    as follows:

    F̲D̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲         
    BA 1[[1 (CR)                   
    BT FD5[[ (CR)
    BU [ or 1 (CR)
    B̲E̲ ̲(̲C̲R̲)̲ ̲ ̲

    The Disk boot command
    is as follows:

    S̲M̲D̲ ̲D̲I̲S̲K̲ ̲ ̲ ̲ ̲ ̲ ̲
    BA 1[25 (CR)
    BM 14[ (CR)
    B̲E̲ ̲A̲ ̲ ̲ ̲ ̲(̲C̲R̲)


                          o If the expected output does
                            not appear then it indicates
                            that it is not possible to
                            boot the test program from
                            that disk drive or floppy drive.

                            Boot the TDX ̲LOOP test program
                            using the other drive.

                            If it is still not possible
                            to boot the test program, it
                            indicates an error in the communication
                            between the Channel Unit and
                            the Processor.

                                 GO TO step 2005.

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

5210                      It is now possible to                    o Examine
                                                                     the
                                                                     output
                                                                     from
                                                                     the
                                                                     test
    start the test program  program in order to verify
                            if the
    A detailed step-by-     program detected any errors.
    step procedure is
    described in section    The error codes and an example
                            of a 
    4.7.2.1.                successful print out
                            is shown in section 4.7.2.2.

    Below are listed the    The test time is app. 15 sec.
    main steps in the
    start procedure of      If correct, then there is no
                            error in
    the TDX ̲LOOP test.      the transmission to/from the
                            peripheral
                            Verify the Distribution Equipment

                                 GO TO step 5900


    Before entering the 
    start command, verify
    that

    a) The parameters "no"
    and "type" in the start 
    command are covered.

    b) The BSM-X is assigned
    to the Off-line TDX 
    Bus.

    c) The LTUX channel
    is enabled.
  
    d)The OPTO Loopback
    cable/tube is 
    connected to the
    LTUX-line in one 
    of the test points
    shown in figure
    4.3.3.5-2.

    The start command is:

    DO TDX ̲LOOPno (CR)
                          o If the test program detected
                            an error, then correct it or
                            replace the failing item.
                            (if TDX crate error. GO TO
                            STEP 4900.)

                            When the error is cleared.

                                 Verify the Distribution
                                 Equipment
                                    GO TO step 5900




























              (1): V24 Loopback Adaptor +
                   V24 Monitoring Module

                   V24 Mon       Test of 
                   Module        Ch1-4
                   S̲l̲o̲t̲ ̲N̲o̲.̲ ̲ ̲ ̲ ̲ ̲ ̲S̲l̲o̲t̲ ̲N̲o̲.̲

                     5, 6         10-7
                    13, 14        18-15
                    ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

                   NOTE:  The actual OPTO Channel Module must be
                          removed before running Loopback test using
                          V24 Monitoring Module and V24 Loopback
                          Adaptor

              (2)  OPTO Loopback Cable

              (3)  OPTO Loopback Tube

              (4)  VDU OPTO: pin 2 - 4, 6 - 7, 5 - 5 - 11
                   MSP OPTO: pin 4 - 6, 7 - 9, 11 - 12

                       Figure 4.3.3.5-2
                   OPTO Adaptor Test Points



    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

5300                      Error in                                 ENTRY

    the Statistical  
    Multiplexer interface
    to a CRT 

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *



5305                      Open the doors to                        Check
                                                                   that
                                                                   the
                                                                   LEDs
                                                                   are
                                                                   as
                                                                   follows:  the
                                                                             Main
                                                                             Site 
    Statistical
    Multiplexer rack
                            POWER   "ON"
                            AT      "ON"
                            SL      "OFF"
                            RT      "OFF"
                            CL      "OFF"
                            LA      "OFF"
                            BO      "OFF"
                            CO      "OFF"
                            RA      "OFF"
                            1-8 ch. indic. "OFF"/FLASHING
                                                   IF TRAFFIC
                                                   OTHERWISE
 OFF

                          If correct, continue to step
                          5310.



                          o If one or more of the LED indications
                            are not as described above,
                            it is necessary to analyze
                            the displayed message.

                                 Troubleshoot the Statistical
                                  Multiplexer. (refer to
                                 Stat.Mux. User's Manual)

                                 Verify the Distribution
                                 Equipment.

                                 GO TO step 5900.


    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *





5310                      Execute a LOCALTEST                      o During
                                                                     the
                                                                     test,
                                                                     the
                                                                     LED
                                                                     indication
                                                                     
                                                                     
    in the Stat. Mux.       should be as follows:
    situated in the main
    site:                        AT    FLASHING
    Depress the "LOCAL           CL    FLASHING
    TEST"                        RA    ON
    switch for minimum
    2 seconds.              To exit the LOCAL TEST mode,
                            momentary depress LOCAL TEST
                            switch or RESET switch.

                            If correct, continue to step
                            5315.


                          o If the LEDs display an error
                            (refer to the Stat. Mux. User's
                            Manual), it indicates an error
                            in the Stat. Mux.

                                 Troubleshoot the Statistical
                                 Multiplexor (refer to
                                 the Stat. Mux User's Manual).

                                 Verify the Distribution
                                 Equipment

                                 GO TO step 5900.

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

5315                      Execute a REMOTE TEST                    o During
                                                                     the
                                                                     test,
                                                                     the
                                                                     LED
                                                                     indicators
    in the Stat. Mux.       in the "LOCAL" Stat. Mux. should
                            be
    situated in the MAIN    as follows:
    site equipment:
                                 AT    FLASHING
    Depress the "REMOTE          CL    FLASHING
    TEST" switch for a           RA    ON
    minimum of 2 seconds.

                            The "REMOTE" Stat. Mux. should
                            be as follows:

                                 AT    FLASHING
                                 CL    ON

                            To exit the REMOTE TEST mode,
                            momentarily depress REMOTE
                            test switch or RESET test.



                            If correct, GO TO step 5325.



                          o If the LEDs display an error
                            (refer to the Stat. Mux. User's
                            Manual), it indicates an error
                            in one of the Stat. Mux.s,
                            the Crypto equipment, modem
                            or the line between the main
                            site and the remote site.

                                 GO TO step 5320.

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


5320                      It is necessary to                       o If
                                                                     no
                                                                     error
                                                                     is
                                                                     detected
                                                                     in
                                                                     the
    verify that there is    Crypto equipment, modem or
                            line 
    no error in the
    Crypto and modem
    transmission                 Continue to step 5325.
    equipment.
    (refer to the Crypto
    and modem equipment
    trouble-
    shooting guides).
                          o If an error is detected and
                            deleted,

                                 Verify the Distribution
                                 Equipment.

                                 GO TO step 5900.

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *




5325                      Boot the TDX ̲LOOP                        o The
                                                                     following
                                                                     output
                                                                     should
                                                                     appear
    test program.                                     
                                  
    A detailed step-by-         "CSS/730 CR 80 M
    step procedure is            TDX TEST VS..."
    described in section         "CPU ["              
                                    
    4.7.2.1.                     "--"
                                                 
    Below are listed        If correct, continue to step
                            5330.
    the main steps in                   
    the procedure of                  
    the TDX ̲LOOP test.           

    Before entering the     
    boot command, verify
    that

    a) The actual DISK or FD
    CTRL is assigned to the
    Off-Line PU

    b) The actual disk
    pack or diskette is  
    mounted
    in the drive.

    The FD boot command is
    as follows:

    F̲D̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲         
    BA 1[[1 (CR)                   
    BT FD5[[ (CR)
    BU [ or 1 (CR)
    B̲E̲ ̲(̲C̲R̲)̲ ̲ ̲ ̲ ̲ ̲ ̲

    The Disk boot command
    is as follows:

    S̲M̲D̲ ̲D̲I̲S̲K̲ ̲ ̲ ̲ ̲ ̲ ̲
    BA 1[25 (CR)
    BM 14[ (CR)
    B̲E̲ ̲A̲ ̲ ̲(̲C̲R̲)̲


                          o If the expected output does
                            not appear then it indicates
                            that it is not possible to
                            boot the test program from
                            that disk drive or floppy drive.

                            Boot the TDX ̲LOOP test program
                            using the other drive.

                            If it is still not possible
                            to boot the test program, it
                            indicates an error in the communication
                            between the Channel Unit and
                            the Processor.

                                 GO TO step 2005.

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *




5330                      It is now possible to                    o Examine
                                                                     the
                                                                     output
                                                                     from
                                                                     the
                                                                     test
    start the test TDX ̲     program in order to verify
                            if the
    LOOP test program.      program detected any errors.
    A detailed step-by-
    step procedure is       The error codes and an example
                            of a
    described in.            successful print out
    section 4.7.2.1.        is shown in section 4.7.2.2.

    Below are listed the    If correct, then there is no
                            error in
    main steps in the       the transmission to/from the
                            peripheral
    start procedure of      on the remote site.
    the TDX ̲LOOP test.      
                                 Verify the distribution
                                 equipment
                                 GO TO Step 5900

    Before entering the 
    start command, verify
    that

    a) The parameter "no"
    in the start command
    is correct.

    b) The BSM-X is assigned
    to the Off-line TDX 
    Bus.

    c) The LTUX channel
    is enabled. 

    d) The LTUX Loop Back
    Adapter is connected
    to the actual channel
    connector in one of 
    the test points shown
    in figure 4.3.3.5-3.

    e) Execute the TDX ̲LOOP
    test until the error is
    found.







                                       (1): V24 Loopback Adaptor +
                                            V24 Monitoring Module

                                            V24 Mon       Test of 
                                            Module        Ch1-4
                                            S̲l̲o̲t̲ ̲N̲o̲.̲ ̲ ̲ ̲ ̲ ̲ ̲S̲l̲o̲t̲ ̲N̲o̲.̲

                                              5, 6         10-7
                                             13, 14        18-15
                                             ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

                                            NOTE: The actual Channel Adaptor must be removed
                                            before running Loopback test using V24 Monitoring
                                            Module and V24 Loopback Adaptor

                                       (2)  V24 Loopback Adaptor

                                       (3)  Press "Local Test" on Main Site Stat. Mux.

                                       (4)  Press "Remote Test" on Main Site Stat. Mux.

                                       (5)  OPTO Loopback Cable

                                       (6)  OPTO Loopback Tube

                                       (7)  VDU OPTO: pin 2 - 4
                                                          6 - 7
                                                          5 - 5 - 11
                                            MSP OPTO: pin 4 - 6
                                                          7 - 9
                                                         11 - 12







                         Figure 4.3.3.5-3…01…Stat. Mux. Testpoints


    The start command is:

    DO TDX ̲LOOPno (CR) 

                          o If the test program detected
                            an error, then correct the
                            failing item or replace it.
                            If TDX/ADAPTOR crate error,

                                 GO TO Step 4900

                            When the error is cleared

                                 Verify the Distribution
                                 Equipment
                                 GO TO Step 5900



    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

5400                      Error detected in                         ENTRY
    the V24 interface
    to the NICS-TARE/    
    SCARS/CCIS or OPTO
    interface to VDU/MSP

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

5405                      Boot the LTU ̲LOOP                        o The
                                                                     following
                                                                     output
                                                                     should
                                                                     appear
    test program.                                     
                                  
    A detailed step-by-         "CSS/730 CR 80 M
    step procedure is            LTU TEST VS..."
    described in section         "CPU ["              
                                    
    4.7.2.1.                     "--"
                                                 
    Below are listed        If correct, continue to step
                            5410.
    the main steps in                   
    the procedure of                  
    the LTU ̲LOOP test.           

    Before entering the     
    boot command, verify
    that

    a) The actual DISK or FD
    CTRL is assigned to the
    Off-Line PU

    b) The actual disk
    pack or diskette    
    is mounted  
    in the drive.

    The FD boot command is
    as follows:

    F̲D̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲         
    BA 1[[1 (CR)                   
    BT FD5[[ (CR)
    BU [ or 1 (CR)
    B̲E̲ ̲(̲C̲R̲)̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

    The Disk boot command
    is as follows:

    S̲M̲D̲ ̲D̲I̲S̲K̲ ̲ ̲ ̲ ̲ ̲ ̲
    BA 1[25 (CR)
    BM 14[ (CR)
    B̲E̲ ̲9̲ ̲ ̲(̲C̲R̲)̲ ̲ ̲ ̲ ̲


                          o If the expected output does
                            not appear, then it indicates
                            that it is not possible to
                            boot the test program from
                            that disk drive or floppy drive.

                            Boot the LTU ̲LOOP test program
                            using the other drive.

                            If it is still not possible
                            to boot the test program, it
                            indicates an error in the communication
                            between the Channel Unit and
                            the Processor.

                                 GO TO step 2005.


    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *



5410                      It is now possible to                    o Examine
                                                                     the
                                                                     output
                                                                     from
                                                                     the
                                                                     test
    start the test LTU ̲     program in order to verify
                            if the
    LOOP test program.      program detected any errors.
    A detailed step-by-
    step procedure is       The error codes and an example
                            of a
    described in section    successful print out
    4.7.2.1.                is shown in section 4.7.2.2.

    Below are listed the    The test time is app. 20 sec.
    main steps in the
    start procedure of      If correct, then it indicates
                            
    the LTU ̲LOOP test.      an error in the external line
                            connected to the LTU-channel.
    Before entering the     It is therefore, verified 
                              
    start command,verify    that there is no error in the
    that                    CAMPS equipment.

    a) The parameter "no"        Verify the Distribution
    in the start command         Equipment.
    is correct.                  GO TO step 5900.

    b) The LTU is assigned       
    to the Off-line PU  

    c) The LIA-N Loop Back
    Adaptor is connected
    to the actual LTU-Line
    connector in one of the
    test points shown in
    Figure 4.3.3.5-4.



    d) Execute the LTU ̲LOOP
    test until the error is
    found.

    The start command is:

    DO LTU ̲LOOP no (CR)


                          o If the test program detected
                            an error in the test points
                            1-7, then correct the failing
                            item or replace it (If Adapter
                            Crate error GO TO step 5800)

                            When the error is cleared,

                                 Verify the Distribution
                                 Equipment
                                 GO TO Step 5900



                          o If the test program detected
                            an error in testpoint 8, then

                                 GO TO Step 5415

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * 
































                                       (1)  LIA-N Loopback Adaptor

                                       (2): V24 Loopback Adaptor +
                                            V24 Monitoring Module

                                            V24 Mon       Test of 
                                            Module        Ch1-4
                                            S̲l̲o̲t̲ ̲N̲o̲.̲ ̲ ̲ ̲ ̲ ̲ ̲S̲l̲o̲t̲ ̲N̲o̲.̲

                                              5, 6         10-7
                                             13, 14        18-15
                                             ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

                                       (3)  V24 Loopback Adaptor

                                       (4)  OPTO Loopback Cable

                                       (5)  OPTO Loopback Tube

                                       (6)  VDU OPTO: pin 2 - 4
                                                          6 - 7
                        Figure 4.3.3.5-4                  38 - 5 - 11
                        LTU Test Points                  MSP OPTO: pin 4 - 6
                                                          7 - 9
                                                         11 - 12




    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * 

5415                      Test of Modem
    connected to LTU-
    line. Check that 
    all front panel
    buttons are out.
    Run the Selftest
    by pushing the
    buttons AL
    (Analogous Loopback)    Inspect that the TST (Test)
                            indicator-
    and                     lamp lights.
    ET (Error Test).        If the ER (Error) indicator-lamp
                            blinks, then the modem is defect.

                                 Troubleshoot the modem
                                 (refer to CPS/TCM/015
                                 and CPS/TCM/016)

    Run the "END TO END"    This test controls that the
                            modems
    Test                    can "speak together" and are
                            OK.

    Check that all front
    panel buttons are OUT.
    Push ET (Error Test)    Inspect that the TST (Test)
                            
    on each modem.          indicator-lamp lights on each
                            modem, then there is an error
                            on one of the modems.

                                 Troubleshoot the modems
                                 (refer to CAMPS/TCM/015
                                 and CPS/TCM/016)

                            and

                                 Verify the Distribution
                                 Equipment
                                 GO TO Step 5900

    The test of the         If the tests of the modems
                            are
    modems is finished.     are executed without detecting
                            any errors, then it is verified
                            that there is no error in the
                            CAMPS equipment and the test
                            of the crypto equipment should
                            be executed.

                                 (refer to crypto equipment
                                 manuals)

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * 



    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

5800                      Adaptor Crate Test                       ENTRY
    Procedure

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *



5805                      Check that                               o If
                                                                     the
                                                                     power
                                                                     level
                                                                     and
                                                                     the
                                                                     LED
                                                                     indica-
    a)the cables are        tions are correct then
    connected properly
    to the adaptor modules          GO TO step 5810
    and there is no
    damage on the mo-     o If the power level measures
                            in the 
    dules.                  Adaptor crate is not correct
                            then

                            a)Check (and replace) the fuses
                            si-
    b)the voltage           tuated on the Adaptor
    level in the Adap-      power supplies.
    ter crate is as
    shown in figure         b)If there is still an error
                            
    4.3.3.5-5.              check the input to the actual
                            power supply.
    c)the Power LED  
    indications in the      If there is any error in the
                            input to
    Adaptor Crate mo-       the power supply then correct
                            the 
    dules are shown         error. The power distribution
                            diagrams
    in section 4.5.         are shown in the Assembly Breakdown
                            (refer to Doc. No. CPS/SDS/017).

                            c)If the power level measured
                            in the Adaptor crate is not
                            correct then

                                 Replace the Adaptor power
                                 supply
                                 (refer to section 4.4)

                            d)If the power level is still
                            not correct then the error
                            must be within the Adaptor
                            crate.

                                 GO TO step 5810

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

















































                  Figure 4.3.3.5-5
Adaptor Crate Layout…86…1    …02…                     …02… …02…    …02…  …02…                   
           
    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

5810                      Adaptor Crate Check
    Procedure             o This step describes the test
                            of the Adaptor Crate.

                            a) Remove all the modules from
                            the Adaptor crate.

                            b) Check all female connectors
                            on the motherboard.

                            c) Remove the Adaptor crate
                            from the rack. Check Voltage
                            level (refer to figure 4.3.3.5-5).

                            d) Check that all wires and
                            connectors are in proper condition
                            and properly connected (refer
                            to figure 4.3.3.5-5)

                            e) Check that it is possible
                            to seat all modules properly
                            in the Adaptor crate.

                          If any errors are detected then
                          correct them or replace the failing
                          module.

                            f) Insert the crate in the
                            rack.
                               Mount the cables.

                            g) Verify the Adaptor Subsystem.


                                 GO TO step 5900                   
* * * * * * * * * * * * * * * * * * * * * * * * * * * *
 * * * *


    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

    Distribution Equipment
5900                      Verification                             ENTRY
    Procedure

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *



5905                             It is necessary to verify
                                 that the original error
                                 indication is deleted
                                 before the troubleshooting
                                 procedure is finished,
                                 therefore

                            1)   GO TO the original ENTRY
                                 POINT in the Off-line
                                 Troubleshooting Tree (defined
                                 by the System Troubleshooting
                                 Tree).

                            2)   Verify that it is possible
                                 to execute the described
                                 step-by- step procedures
                                 without detecting any
                                 errors.


                            3)   If no errors are detected
                                 the troubleshooting of
                                 the Distribution Equipment
                                 is finished.

                            4)   Complete failure report
                                 and logbook (refer to
                                 section 6)