top - download
⟦5fb46956c⟧ Wang Wps File
Length: 2928 (0xb70)
Types: Wang Wps File
Notes: CPS/LST/043
Names: »4522A «
Derivation
└─⟦e27572af5⟧ Bits:30006187 8" Wang WCS floppy, CR 0422A
└─ ⟦this⟧ »4522A «
WangText
…02…CPS/LST/043
…02…IJO/831114…02……02…#
RESYNC.MODULE CR 80112
F/W PROGRAM LISTING…02……02…CAMPS
LIST OF CONTENT
---------------
0 SCOPE ..........................................
4
1 APPLICABLE DOCUMENTS ...........................
4
2 INTRODUCTION ...................................
4
3 FLOW CHARTS ....................................
5
3.1 MAIN MODULE ................................
5
3.2 RESET AND INTERRUPT ........................
5
4 PROGRAM LISTING ................................
9
0̲ ̲ ̲S̲C̲O̲P̲E̲
This document describes in detail the F/W of the Resynchronization
Module. The F/W listing also describes the function
of the Module.
1̲ ̲ ̲A̲P̲P̲L̲I̲C̲A̲B̲L̲E̲ ̲D̲O̲C̲U̲M̲E̲N̲T̲S̲
DOC (1) RESYNCHRONIZATION MODULE
CR 80112/000--/0-
TECHNICAL MANUAL
CPS/TCM/030
DOC (2) RESYNCHRONIZATION MODULE
CR 80112/000--/0-
PRODUCT SPECIFICATION
CPS/PSP/001
2̲ ̲ ̲I̲N̲T̲R̲O̲D̲U̲C̲T̲I̲O̲N̲
The F/W is described by means of:
1) Flow Charts
2) F/W Source Listing including comments.
3̲ ̲ ̲F̲L̲O̲W̲ ̲C̲H̲A̲R̲T̲S̲
3.1 M̲A̲I̲N̲ ̲M̲O̲D̲U̲L̲E̲
In figure 1-1 is shown the Main Flow of the Program.
The flow is identical to both channels, which are indicated
by 1/2, meaning that a specific routine or circuit
in the flow chart marked 1/2 in the listing will appear
as xxx1 for channel 1, and xxx2 for channel 2.
Entry/Exit points in the flow charts are indicated
by sheet letter , where flow is continued.
3.2 R̲E̲S̲E̲T̲ ̲A̲N̲D̲ ̲T̲I̲M̲E̲R̲ ̲I̲N̲T̲E̲R̲R̲U̲P̲T̲
In figure 1-2 is shown the flow of the Reset- and Interrupt
routines, these are common and apply to both channels.
FIGURE 1-1
Sheet 1 of 2 sheets.
FIGURE 1.1
Sheet 2 of 2 sheets.
FIGURE 1-2
4̲ ̲ ̲P̲R̲O̲G̲R̲A̲M̲ ̲L̲I̲S̲T̲I̲N̲G̲
On the following pages are listed the Resynchronization
Program. The Source Code is resident in U27 (Single
chip processor 8748).
Comments between stars in the listing explains content
and function of each submodule.
Throughout the program the following syntax is used:
Circuit xxxA: Host Interface
Circuit xxxB: Crypto Interface
Absolute location of all Labels used are listed on
last page.