…02…GT/810331…02……02…#
ATDL/MBDL Converter Recommended Spare
Parts List (RSPL)…02……02…








                T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲



 1  SCOPE ...............................................
  4

 2  METHODOLOGY .........................................
  4
   2.1  PERIOD OF SUPPORT ...............................
    4
   2.2  INSURANCE TYPE ITEMS ............................
    4
   2.3  FORMULA FOR SPARES CALCULATION ..................
    5

 3  AVAILABILITY ........................................
 14
   3.1  FORMULA FOR AVAILABILITY CALCULATION ............
   14
   3.2  AVAILABILITY FOR ONE CONVERTER UNIT .............
   14



                        1̲.̲ ̲ ̲S̲C̲O̲P̲E̲



         The scope of this document is to present a Recommended
         Spare Parts List (RSPL), which will support the achievement
         of a predicted availability of each ATDL/MBDL Converter
         (AMC) with a confidence level of c.









                     2̲.̲ ̲ ̲M̲E̲T̲H̲O̲D̲O̲L̲O̲G̲Y̲



2.1      P̲E̲R̲I̲O̲D̲ ̲O̲F̲ ̲S̲U̲P̲P̲O̲R̲T̲

         The RSPL for each AMC (Unit level RSPL) has been prepared
         to ensure 90 days of operation, with a confidence level
         of 90%, whereas the National depot level RSPL has been
         calculated for countries with resp 1,2 and 4 units
         to ensure the presence of spares required to support
         the units for a period of 180 days, with a confidence
         level of 90%

         The RSPL for NATO common depot level and 5th echelon
         level has been calculated for a total amount of AMC's
         of 8,9 and 10 for a period of 270 days, with a confidence
         level of 80%.



2.2      I̲N̲S̲U̲R̲A̲N̲C̲E̲ ̲T̲Y̲P̲E̲ ̲I̲T̲E̲M̲S̲ ̲A̲N̲D̲ ̲M̲A̲I̲N̲T̲E̲N̲A̲N̲C̲E̲ ̲F̲L̲O̲A̲T̲

         Insurance type items are items, which, though not required
         for pure statistical reasons, must be included due
         to long lead time.  Insurance type Items have been
         included at unit as well as national and NATO level.
          Due to the availability of spares on unit level the
         amount of spares on the higher levels have been decreased
         as result of a Maintenance Float consideration.





2.3      F̲O̲R̲M̲U̲L̲A̲ ̲F̲O̲R̲ ̲S̲P̲A̲R̲E̲S̲ ̲C̲A̲L̲C̲U̲L̲A̲T̲I̲O̲N̲



         M̲e̲t̲h̲o̲d̲ ̲t̲o̲ ̲C̲a̲l̲c̲u̲l̲a̲t̲e̲ ̲N̲u̲m̲b̲e̲r̲ ̲o̲f̲ ̲S̲p̲a̲r̲e̲s̲

         In order to determine the number of spares it will
         be assumed that the failure rate of each module (circuit
         board) has an exponential distribution.  This approximation
         holds true for electronic equipment throughout its
         useful life, i.e. wear-out phenomena can be ignored.

         Thus the probability mass function for each module
         is:

              p(t) = (1/MTBF) x exp(-t/MTBF)

         where MTBF is the Mean Time Between Failure for that
         module.

         It can be shown that the probability of observing exactly
         i failures over a period of t operating hours is given
         by the Poisson distribution:



                                             i                       
                        p (i)  =     (̲t̲/̲M̲T̲B̲F̲)̲ ̲ ̲ ̲x̲ ̲e̲x̲p̲(̲-̲ ̲t̲/̲M̲T̲B̲F̲)̲      
                                                                     
                                              i!                     




         The Period t corresponds to the accumulated operating
         period for the involved modules.

         Therefore, the probability of observing r or less failures
         during a period t is determined by the cumulative Poisson
         distribution:



                                                                     
                                r          i                         
                                   (̲t̲/̲M̲T̲B̲F̲)̲ ̲ ̲x̲ ̲e̲x̲p̲(̲-̲t̲/̲M̲T̲B̲F̲)̲          
           P (failures  r) =                                         
                                             i!                      
                              i = 0                                  
                                                                     


         To determine the number of spares r required to obtain
         a confidence level c for a given period  is equivalent
         to determining the minimal r for which the probability
         of having more than r failures during the period covered
         is less than 1-c.



         The following equation has to be solved for r:

                                                                     
                     i =                                             
                                  i                                  
                                 m̲ ̲ ̲ ̲x̲ ̲e̲x̲p̲ ̲(̲-̲m̲)̲                      
            max                                                      
                                       i !            1-c            
             r       i = r+1                                         
                                                                     
                                                                     


                 r =    number of spares required to obtain
                 the
                          required confidence level

                 m = N   x    ̲T̲ ̲
                              MTBF
                                                           
          
                 N =    total installed parts population. The
                 total installed population for a depot is determined
                 by the number installed items at the sites
                 involved.

                 T =    length of period for which stock is
                          required


                 MTBF = Mean Time Between Failure (MTBF = 10…0e…6…0f…/
                  )

                      = failure rate per million hours.



         Alternatively determine smallest integer r for which


                                             r    i                  
                                                 m                   
                   c    exp  (-m)  x              ̲ ̲ ̲                 
                                                                     
                                                 i!                  
                                          i = 0                      



         The MTTR values are based on the supposition that spares,
         tools and test equipment are available to the maintenance
         personnel.


             T̲a̲b̲l̲e̲ ̲2̲.̲1̲:̲ ̲U̲n̲i̲t̲ ̲L̲e̲v̲e̲l̲ ̲R̲S̲P̲L̲

                           CR              MTTR  Lambda  Rec
Ref                        Part        Part No   Qty     (min)  /10…0e…6…0f…h  Spares Note

1  C̲R̲8̲0̲ ̲S̲t̲a̲n̲d̲a̲r̲d̲ ̲M̲o̲d̲u̲l̲e̲s̲
1a SCM, CR 80100           4.04115-02  1    60   33.2    1      1
1b CPU, CR 80101           4.04120-00  1    60   18.8    1      1
1c 32K RAM, CR8006         4.04114-00  1    60   24.6    1      1
1d V24 I/F, CR8030         4.04125-00  1    30    7.5    1      1
1e 4K PROM, CR8003         4.04118-02  1    60    5.8    1      1
1f Power Supply, CR 8022   4.04122-00  2    30   19.2    1
2  L̲T̲U̲'̲s̲ ̲a̲n̲d̲ ̲M̲o̲d̲e̲m̲s̲
2a ATDL LTU, CR8073        4.04161-01  2    30   21.7    1      1
2b MBDL LTU, CR8074        4.04151-01  2    30    9.8    1      1
2c ATDL Modem CR8075       4.04159-01  4    30   20.6    1
2d MBDL Modem I/F, CR8077  4.04160-01  4    30   10.3    1      1
3  R̲a̲c̲k̲,̲ ̲C̲r̲a̲t̲e̲s̲ ̲a̲n̲d̲
   A̲c̲c̲e̲s̲s̲o̲r̲i̲e̲s̲
3a Rack                    4.44400-00  1    -     0      0
3b Crate Assy (incl Bus
   Term & Ext)             4.07001-03  2   120   5.4     0
3c Subbus                  5.04105-00  1   120   1.1     0
3d Fan                     4.13100-00  1    30   1.0     1      1
3e Mains Filter            4.07002-01  1    30   1.6     1…02…1
3f Power Distribution      4.39100-00  1    30   1.0     0
3g ATDL Line Panel         5.39129-00  4    30   2.2     0
3h MBDL Line Panel         5.39128-00  4    30   0.7     0
3i AV24 I/F Panel          5.39111-01  1    30   0.2     0
3j Line Panel Support      5.39130-00  1    -     0      0
3k ATDL DCE conn. Panel    4.04237-01  4    60   0.3     0
3l ATDL DTE conn. Panel    4.04238-01  2    60   0.5     0
3m ATDL conn. cable        5.05404-00  6    60   0.1     0
3n MBDL Connector Board    5.04199-00  2   120   1.1     0
3o Int. Sign cable         5.05343-00  8    60   0.1     0
3p Power cable                 -       2   120   0.1     0
3q V24 cable               5.05344-00  1   120   0.1     0
4  S̲p̲e̲c̲i̲a̲l̲ ̲M̲o̲d̲u̲l̲e̲s̲
4a Operators Panel         4.04211-00  1    60   61.5    1
5  P̲a̲t̲c̲h̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲
5a Patch Panel                -        1    60   35.1    1      1
5b Patch Cord                 -        16   30    1.0    0
5c Term Plugs                 -        8    30    0.5    0
5d V24 cable                  -        16   30    0.2    0

            Note 1:  Insurance Type item


        T̲a̲b̲l̲e̲ ̲2̲.̲2̲a̲ ̲N̲a̲t̲i̲o̲n̲a̲l̲ ̲d̲e̲p̲o̲t̲ ̲l̲e̲v̲e̲l̲ ̲R̲S̲P̲L̲
                C̲o̲u̲n̲t̲r̲y̲ ̲w̲i̲t̲h̲ ̲1̲ ̲u̲n̲i̲t̲

                           CR              MTTR  Lambda  Rec
Ref                        Part        Part No   Qty     (min)  /10…0e…6…0f…h  Spares Note

1  C̲R̲8̲0̲ ̲S̲t̲a̲n̲d̲a̲r̲d̲ ̲M̲o̲d̲u̲l̲e̲s̲
1a SCM, CR 80100           4.04115-02  1    60   33.2    0      2
1b CPU, CR 80101           4.04120-00  1    60   18.8    0      
                                                                
1c 32K RAM, CR8006         4.04114-00  1    60   24.6    0      2
1d V24 I/F, CR8030         4.04125-00  1    30    7.5    0      
                                                                
1e 4K PROM, CR8003         4.04118-02  1    60    5.8    0      
                                                                
1f Power Supply, CR 8022   4.04122-00  2    30   19.2    0      2
2  L̲T̲U̲'̲s̲ ̲a̲n̲d̲ ̲M̲o̲d̲e̲m̲s̲
2a ATDL LTU, CR8073        4.04161-01  2    30   21.7    0      2
2b MBDL LTU, CR8074        4.04151-01  2    30    9.8    0      
                                                                
2c ATDL Modem CR8075       4.04159-01  4    30   20.6    0      2
2d MBDL Modem I/F, CR8077  4.04160-01  4    30   10.3    0      2
3  R̲a̲c̲k̲,̲ ̲C̲r̲a̲t̲e̲s̲ ̲a̲n̲d̲
   A̲c̲c̲e̲s̲s̲o̲r̲i̲e̲s̲
3a Rack                    4.44400-00  1    -     0      0
3b Crate Assy (incl Bus
   Term & Ext)             4.07001-03  2   120   5.4     1      1
3c Subbus                  5.04105-00  1   120   1.1     1      1
3d Fan                     4.13100-00  1    30   1.0     0
3e Mains Filter            4.07002-01  1    30   1.6     0
3f Power Distribution      4.39100-00  1    30   1.0     1      1
3g ATDL Line Panel         5.39129-00  4    30   2.2     1      1
3h MBDL Line Panel         5.39128-00  4    30   0.7     1      1
3i AV24 I/F Panel          5.39111-01  1    30   0.2     1      1
3j Line Panel Support      5.39130-00  1    -     0      0
3k ATDL DCE conn. Panel    4.04237-01  4    60   0.3     1      1
3l ATDL DTE conn. Panel    4.04238-01  2    60   0.5     1      1
3m ATDL conn. cable        5.05404-00  6    60   0.1     1      1
3n MBDL Connector Board    5.04199-00  2   120   1.1     1      1
3o Int. Sign cable         5.05343-00  8    60   0.1     1      1
3p Power cable                 -       2   120   0.1     1      1
3q V24 cable               5.05344-00  1   120   0.1     1      1
4  S̲p̲e̲c̲i̲a̲l̲ ̲M̲o̲d̲u̲l̲e̲s̲
4a Operators Panel         4.04211-00  1    60   61.5    0      2
5  P̲a̲t̲c̲h̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲
5a Patch Panel                -        1    60   35.1    0      2
5b Patch Cord                 -        16   30    1.0    1      1
5c Term Plugs                 -        8    30    0.5    1      1
5d V24 cable                  -        16   30    0.2    1      1

            Note 1:  Insurance Type Item
       Note 2:  Maintenance float reduction.


        T̲a̲b̲l̲e̲ ̲2̲.̲2̲b̲ ̲N̲a̲t̲i̲o̲n̲a̲l̲ ̲d̲e̲p̲o̲t̲ ̲l̲e̲v̲e̲l̲ ̲R̲S̲P̲L̲
                C̲o̲u̲n̲t̲r̲y̲ ̲w̲i̲t̲h̲ ̲2̲ ̲u̲n̲i̲t̲s̲

                           CR              MTTR  Lambda  Rec
Ref                        Part        Part No   Qty     (min)  /10…0e…6…0f…h  Spares Note

1  C̲R̲8̲0̲ ̲S̲t̲a̲n̲d̲a̲r̲d̲ ̲M̲o̲d̲u̲l̲e̲s̲
1a SCM, CR 80100           4.04115-02  2    60   33.2    0      2
1b CPU, CR 80101           4.04120-00  2    60   18.8    0      2
1c 32K RAM, CR8006         4.04114-00  2    60   24.6    0      2
1d V24 I/F, CR8030         4.04125-00  2    30    7.5    0      
                                                                
1e 4K PROM, CR8003         4.04118-02  2    60    5.8    0      
                                                                
1f Power Supply, CR 8022   4.04122-00  4    30   19.2    0      2
2  L̲T̲U̲'̲s̲ ̲a̲n̲d̲ ̲M̲o̲d̲e̲m̲s̲
2a ATDL LTU, CR8073        4.04161-01  4    30   21.7    0      2
2b MBDL LTU, CR8074        4.04151-01  4    30    9.8    0      2
2c ATDL Modem CR8075       4.04159-01  8    30   20.6    1      2
2d MBDL Modem I/F, CR8077  4.04160-01  8    30   10.3    0      2
3  R̲a̲c̲k̲,̲ ̲C̲r̲a̲t̲e̲s̲ ̲a̲n̲d̲
   A̲c̲c̲e̲s̲s̲o̲r̲i̲e̲s̲
3a Rack                    4.44400-00  2    -     0      0
3b Crate Assy (incl Bus
   Term & Ext)             4.07001-03  4   120   5.4     1      1
3c Subbus                  5.04105-00  2   120   1.1     1      1
3d Fan                     4.13100-00  2    30   1.0     0
3e Mains Filter            4.07002-01  2    30   1.6     0
3f Power Distribution      4.39100-00  2    30   1.0     1      1
3g ATDL Line Panel         5.39129-00  8    30   2.2     1      1
3h MBDL Line Panel         5.39128-00  8    30   0.7     1      1
3i AV24 I/F Panel          5.39111-01  2    30   0.2     1      1
3j Line Panel Support      5.39130-00  2    -     0      0
3k ATDL DCE conn. Panel    4.04237-01  8    60   0.3     1      1
3l ATDL DTE conn. Panel    4.04238-01  4    60   0.5     1      1
3m ATDL conn. cable        5.05404-00  12   60   0.1     1      1
3n MBDL Connector Board    5.04199-00  4   120   1.1     1      1
3o Int. Sign cable         5.05343-00  16   60   0.1     1      1
3p Power cable                 -       4   120   0.1     1      1
3q V24 cable               5.05344-00  2   120   0.1     1      1
4  S̲p̲e̲c̲i̲a̲l̲ ̲M̲o̲d̲u̲l̲e̲s̲
4a Operators Panel         4.04211-00  2    60   61.5    0      2
5  P̲a̲t̲c̲h̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲
5a Patch Panel                -        2    60   35.1    0      2
5b Patch Cord                 -        32   30    1.0    1
5c Term Plugs                 -        16   30    0.5    1      1
5d V24 cable                  -        32   30    0.2    1      1

           Note 1: Insurance types item.
        Note 2:  Maintenance Float Reduction


        T̲a̲b̲l̲e̲ ̲2̲.̲2̲c̲ ̲N̲a̲t̲i̲o̲n̲a̲l̲ ̲d̲e̲p̲o̲t̲ ̲l̲e̲v̲e̲l̲ ̲R̲S̲P̲L̲
                C̲o̲u̲n̲t̲r̲y̲ ̲w̲i̲t̲h̲ ̲4̲ ̲u̲n̲i̲t̲s̲

                           CR              MTTR  Lambda  Rec
Ref                        Part        Part No   Qty     (min)  /10…0e…6…0f…h  Spares Note

1  C̲R̲8̲0̲ ̲S̲t̲a̲n̲d̲a̲r̲d̲ ̲M̲o̲d̲u̲l̲e̲s̲
1a SCM, CR 80100           4.04115-02  4    60   33.2    1      
1b CPU, CR 80101           4.04120-00  4    60   18.8    0      2
1c 32K RAM, CR8006         4.04114-00  4    60   24.6    0      2
1d V24 I/F, CR8030         4.04125-00  4    30    7.5    0      
1e 4K PROM, CR8003         4.04118-02  4    60    5.8    0      
                                                                
1f Power Supply, CR 8022   4.04122-00  8    30   19.2    1      2
2  L̲T̲U̲'̲s̲ ̲a̲n̲d̲ ̲M̲o̲d̲e̲m̲s̲
2a ATDL LTU, CR8073        4.04161-01  8    30   21.7    1      2
2b MBDL LTU, CR8074        4.04151-01  8    30    9.8    0      2
2c ATDL Modem CR8075       4.04159-01  16   30   20.6    2      2
2d MBDL Modem I/F, CR8077  4.04160-01  16   30   10.3    1      2
3  R̲a̲c̲k̲,̲ ̲C̲r̲a̲t̲e̲s̲ ̲a̲n̲d̲
   A̲c̲c̲e̲s̲s̲o̲r̲i̲e̲s̲
3a Rack                    4.44400-00  4    -     0      0
3b Crate Assy (incl Bus
   Term & Ext)             4.07001-03  8   120   5.4     1
3c Subbus                  5.04105-00  4   120   1.1     1      1
3d Fan                     4.13100-00  4    30   1.0     1      1
3e Mains Filter            4.07002-01  4    30   1.6     0
3f Power Distribution      4.39100-00  4    30   1.0     0      
                                                                
3g ATDL Line Panel         5.39129-00  16   30   2.2     1      
                                                                
3h MBDL Line Panel         5.39128-00  16   30   0.7     1      1
3i AV24 I/F Panel          5.39111-01  4    30   0.2     1      1
3j Line Panel Support      5.39130-00  4    -     0      0
3k ATDL DCE conn. Panel    4.04237-01  16   60   0.3     1      1
3l ATDL DTE conn. Panel    4.04238-01  8    60   0.5     1      1
3m ATDL conn. cable        5.05404-00  24   60   0.1     1      1
3n MBDL Connector Board    5.04199-00  8   120   1.1     1      1
3o Int. Sign cable         5.05343-00  32   60   0.1     1      1
3p Power cable                 -       8   120   0.1     1      1
3q V24 cable               5.05344-00  4   120   0.1     1      1
4  S̲p̲e̲c̲i̲a̲l̲ ̲M̲o̲d̲u̲l̲e̲s̲
4a Operators Panel         4.04211-00  4    60   61.5    1      2
5  P̲a̲t̲c̲h̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲
5a Patch Panel                -        4    60   35.1    0      2
5b Patch Cord                 -        64   30    1.0    1
5c Term Plugs                 -        32   30    0.5    1      1
5d V24 cable                  -        64   30    0.2    1      1

           Note 1: Insurance types item.
        Note 2:  Maintenance Float Reduction


T̲a̲b̲l̲e̲ ̲2̲.̲3̲a̲ ̲ ̲N̲A̲T̲O̲ ̲C̲o̲m̲m̲o̲n̲ ̲d̲e̲p̲o̲t̲ ̲l̲e̲v̲e̲l̲ ̲a̲n̲d̲ ̲5̲t̲h̲ ̲e̲c̲h̲e̲l̲o̲n̲ ̲l̲e̲v̲e̲l̲ ̲R̲S̲L̲P̲
           for a total amount of 8 units.

                           CR              MTTR  Lambda  Rec
Ref                        Part        Part No   Qty     (min)  /10…0e…6…0f…h  Spares Note

1  C̲R̲8̲0̲ ̲S̲t̲a̲n̲d̲a̲r̲d̲ ̲M̲o̲d̲u̲l̲e̲s̲
1a SCM, CR 80100           4.04115-02  8    60   33.2    2      2
1b CPU, CR 80101           4.04120-00  8    60   18.8    1      2
1c 32K RAM, CR8006         4.04114-00  8    60   24.6    1      2
1d V24 I/F, CR8030         4.04125-00  8    30    7.5    1
1e 4K PROM, CR8003         4.04118-02  8    60    5.8    1
1f Power Supply, CR 8022   4.04122-00  16   30   19.2    2      2
2  L̲T̲U̲'̲s̲ ̲a̲n̲d̲ ̲M̲o̲d̲e̲m̲s̲
2a ATDL LTU, CR8073        4.04161-01  16   30   21.7    2      2
2b MBDL LTU, CR8074        4.04151-01  16   30    9.8    1      2
2c ATDL Modem CR8075       4.04159-01  32   30   20.6    3      2
2d MBDL Modem I/F, CR8077  4.04160-01  32   30   10.3    2      2
3  R̲a̲c̲k̲,̲ ̲C̲r̲a̲t̲e̲s̲ ̲a̲n̲d̲
   A̲c̲c̲e̲s̲s̲o̲r̲i̲e̲s̲
3a Rack                    4.44400-00  8    -     0      0
3b Crate Assy (incl Bus
   Term & Ext)             4.07001-03  16  120   5.4     1
3c Subbus                  5.04105-00  8   120   1.1     1      1
3d Fan                     4.13100-00  8    30   1.0     1      1
3e Mains Filter            4.07002-01  8    30   1.6     1      1
3f Power Distribution      4.39100-00  8    30   1.0     1      1
3g ATDL Line Panel         5.39129-00  32   30   2.2     1
3h MBDL Line Panel         5.39128-00  32   30   0.7     1      1
3i AV24 I/F Panel          5.39111-01  8    30   0.2     1      1
3j Line Panel Support      5.39130-00  8    -     0      0
3k ATDL DCE conn. Panel    4.04237-01  32   60   0.3     1      1
3l ATDL DTE conn. Panel    4.04238-01  16   60   0.5     1      1
3m ATDL conn. cable        5.05404-00  48   60   0.1     1      1
3n MBDL Connector Board    5.04199-00  16  120   1.1     1      1
3o Int. Sign cable         5.05343-00  64   60   0.1     1      1
3p Power cable                 -       16  120   0.1     1      1
3q V24 cable               5.05344-00  8   120   0.1     1      1
4  S̲p̲e̲c̲i̲a̲l̲ ̲M̲o̲d̲u̲l̲e̲s̲
4a Operators Panel         4.04211-00  8    60   61.5    3      2
5  P̲a̲t̲c̲h̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲
5a Patch Panel                -        8    60   35.1    1      2
5b Patch Cord                 -        128  30    1.0    1      2
5c Term Plugs                 -        64   30    0.5    1      1
5d V24 cable                  -        128  30    0.2    1      1

            Note 1:  Insurance type item
        Note 2:  Maintenance Float Reduction


T̲a̲b̲l̲e̲ ̲2̲.̲3̲b̲ ̲N̲A̲T̲O̲ ̲c̲o̲m̲m̲o̲n̲ ̲d̲e̲p̲o̲t̲ ̲l̲e̲v̲e̲l̲ ̲a̲n̲d̲ ̲5̲t̲h̲ ̲e̲c̲h̲e̲l̲o̲n̲ ̲l̲e̲v̲e̲l̲ ̲R̲S̲L̲P̲
           f̲o̲r̲ ̲a̲ ̲t̲o̲t̲a̲l̲ ̲a̲m̲o̲u̲n̲t̲ ̲o̲f̲ ̲9̲ ̲u̲n̲i̲t̲s̲

                           CR              MTTR  Lambda  Rec
Ref                        Part        Part No   Qty     (min)  /10…0e…6…0f…h  Spares Note

1  C̲R̲8̲0̲ ̲S̲t̲a̲n̲d̲a̲r̲d̲ ̲M̲o̲d̲u̲l̲e̲s̲
1a SCM, CR 80100           4.04115-02  9    60   33.2    2      2
1b CPU, CR 80101           4.04120-00  9    60   18.8    1      2
1c 32K RAM, CR8006         4.04114-00  9    60   24.6    1      2
1d V24 I/F, CR8030         4.04125-00  9    30    7.5    1
1e 4K PROM, CR8003         4.04118-02  9    60    5.8    1
1f Power Supply, CR 8022   4.04122-00  18   30   19.2    2      2
2  L̲T̲U̲'̲s̲ ̲a̲n̲d̲ ̲M̲o̲d̲e̲m̲s̲
2a ATDL LTU, CR8073        4.04161-01  18   30   21.7    2      2
2b MBDL LTU, CR8074        4.04151-01  18   30    9.8    1      2
2c ATDL Modem CR8075       4.04159-01  36   30   20.6    3      2
2d MBDL Modem I/F, CR8077  4.04160-01  36   30   10.3    2      2
3  R̲a̲c̲k̲,̲ ̲C̲r̲a̲t̲e̲s̲ ̲a̲n̲d̲
   A̲c̲c̲e̲s̲s̲o̲r̲i̲e̲s̲
3a Rack                    4.44400-00  9    -     0      0
3b Crate Assy (incl Bus
   Term & Ext)             4.07001-03  18  120   5.4     1
3c Subbus                  5.04105-00  9   120   1.1     1      1
3d Fan                     4.13100-00  9    30   1.0     1      1
3e Mains Filter            4.07002-01  9    30   1.6     1      1
3f Power Distribution      4.39100-00  9    30   1.0     1      1
3g ATDL Line Panel         5.39129-00  36   30   2.2     1
3h MBDL Line Panel         5.39128-00  36   30   0.7     1
3i AV24 I/F Panel          5.39111-01  9    30   0.2     1      1
3j Line Panel Support      5.39130-00  9    -     0      0
3k ATDL DCE conn. Panel    4.04237-01  36   60   0.3     1      1
3l ATDL DTE conn. Panel    4.04238-01  18   60   0.5     1      1
3m ATDL conn. cable        5.05404-00  54   60   0.1     1      1
3n MBDL Connector Board    5.04199-00  18  120   1.1     1      1
3o Int. Sign cable         5.05343-00  72   60   0.1     1      1
3p Power cable                 -       18  120   0.1     1      1
3q V24 cable               5.05344-00  9   120   0.1     1      1
4  S̲p̲e̲c̲i̲a̲l̲ ̲M̲o̲d̲u̲l̲e̲s̲
4a Operators Panel         4.04211-00  9    60   61.5    3      2
5  P̲a̲t̲c̲h̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲
5a Patch Panel                -        9    60   35.1    1      2
5b Patch Cord                 -        144  30    1.0    1      2
5c Term Plugs                 -        72   30    0.5    1      
                                                                
5d V24 cable                  -        144  30    0.2    1      1

            Note 1:  Insurance type item
        Note 2:  Maintenance Float Reduction



T̲a̲b̲l̲e̲ ̲2̲.̲3̲c̲ ̲N̲A̲T̲O̲ ̲c̲o̲m̲m̲o̲n̲ ̲d̲e̲p̲o̲t̲ ̲l̲e̲v̲e̲l̲ ̲a̲n̲d̲ ̲5̲t̲h̲ ̲e̲c̲h̲e̲l̲o̲n̲ ̲l̲e̲v̲e̲l̲ ̲R̲S̲P̲L̲
           for a total amount of 10 units

                           CR              MTTR  Lambda  Rec
Ref                        Part        Part No   Qty     (min)  /10…0e…6…0f…h  Spares Note

1  C̲R̲8̲0̲ ̲S̲t̲a̲n̲d̲a̲r̲d̲ ̲M̲o̲d̲u̲l̲e̲s̲
1a SCM, CR 80100           4.04115-02  10   60   33.2    2      2
1b CPU, CR 80101           4.04120-00  10   60   18.8    1      2
1c 32K RAM, CR8006         4.04114-00  10   60   24.6    1      2
1d V24 I/F, CR8030         4.04125-00  10   30    7.5    1
1e 4K PROM, CR8003         4.04118-02  10   60    5.8    1
1f Power Supply, CR 8022   4.04122-00  20   30   19.2    2      2
2  L̲T̲U̲'̲s̲ ̲a̲n̲d̲ ̲M̲o̲d̲e̲m̲s̲
2a ATDL LTU, CR8073        4.04161-01  20   30   21.7    2      2
2b MBDL LTU, CR8074        4.04151-01  20   30    9.8    1      2
2c ATDL Modem CR8075       4.04159-01  40   30   20.6    3      2
2d MBDL Modem I/F, CR8077  4.04160-01  40   30   10.3    2      2
3  R̲a̲c̲k̲,̲ ̲C̲r̲a̲t̲e̲s̲ ̲a̲n̲d̲
   A̲c̲c̲e̲s̲s̲o̲r̲i̲e̲s̲
3a Rack                    4.44400-00  10   -     0      0
3b Crate Assy (incl Bus
   Term & Ext)             4.07001-03  20  120   5.4     1
3c Subbus                  5.04105-00  10  120   1.1     1      1
3d Fan                     4.13100-00  10   30   1.0     1      1
3e Mains Filter            4.07002-01  10   30   1.6     1      1
3f Power Distribution      4.39100-00  10   30   1.0     1      1
3g ATDL Line Panel         5.39129-00  40   30   2.2     1      
3h MBDL Line Panel         5.39128-00  40   30   0.7     1      1
3i AV24 I/F Panel          5.39111-01  10   30   0.2     1      1
3j Line Panel Support      5.39130-00  10   -     0      0
3k ATDL DCE conn. Panel    4.04237-01  40   60   0.3     1      1
3l ATDL DTE conn. Panel    4.04238-01  20   60   0.5     1      1
3m ATDL conn. cable        5.05404-00  60   60   0.1     1      1
3n MBDL Connector Board    5.04199-00  20  120   1.1     1      1
3o Int. Sign cable         5.05343-00  80   60   0.1     1      1
3p Power cable                 -       20  120   0.1     1      1
3q V24 cable               5.05344-00  10  120   0.1     1      1
4  S̲p̲e̲c̲i̲a̲l̲ ̲M̲o̲d̲u̲l̲e̲s̲
4a Operators Panel         4.04211-00  10   60   61.5    3      2
5  P̲a̲t̲c̲h̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲
5a Patch Panel                -        10   60   35.1    1      2
5b Patch Cord                 -        160  30    1.0    1      2
5c Term Plugs                 -        80   30    0.5    1      
                                                                
5d V24 cable                  -        160  30    0.2    1      1

            Note 1:  Insurance type item
        Note 2:  Maintenance Float Reduction


                  3̲ ̲ ̲A̲V̲A̲I̲L̲A̲B̲I̲L̲I̲T̲Y̲



3.1                        F̲O̲R̲M̲U̲L̲A̲ ̲F̲O̲R̲ ̲A̲V̲A̲I̲L̲A̲B̲I̲L̲I̲T̲Y̲ ̲C̲A̲L̲C̲U̲L̲A̲T̲I̲O̲N̲

   The Mean Time Between Failure (MTBF) for one ATDL/MBDL
   Converter Unit is calculated as:

                                                                   
                                                                   
                                                                   
           MTBF =         ̲ ̲ ̲ ̲ ̲ ̲1̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲                            
                                                                   
                                                                   
                            n…0f…i…0e…  …0f…i…0e…                              
                         i                                         
                                                                   




 …06…1         …02…   …02…   …02…   …02…                                           
         The Mean Time To Repair (MTTR) for one ATDL/MBDL Converter Unit is calculated
         as:





                                                                   
                                                                   
                                                                   
           MTTR =   i …0e…n…0f…i  i …0f…MTTR…0f…i                           
                    ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲                          
                                                                   
                                                                   
                       i  n…0f…i…0e…   …0f…i…0e…                               




         The Availability for one ATDL/MBDL Converter unit is
         calculated as

                                                                   
                                                                   
           A =     ̲ ̲ ̲M̲T̲B̲F̲F̲ ̲ ̲ ̲                                      
                                                                   
                                                                   
                  MTBF + MTTR                                      




3.2      A̲V̲A̲I̲L̲A̲B̲I̲L̲I̲T̲Y̲ ̲F̲O̲R̲ ̲O̲N̲E̲ ̲C̲O̲N̲V̲E̲R̲T̲E̲R̲ ̲U̲N̲I̲T̲

                 Without         With
                 Patch Panel     Patch Panel

         MTBF    2450 hours      2178 hours

         MTTR      44 min          45 min

         A       99.970%         99.966%

         Considering failures affecting all 8 channels, the
         MTBF is 5̲0̲8̲4̲ ̲h̲o̲u̲r̲s̲