3.2.4.6.2    E̲n̲g̲i̲n̲e̲e̲r̲i̲n̲g̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲s̲ ̲D̲e̲t̲a̲i̲l̲e̲d̲ ̲D̲e̲f̲i̲n̲i̲t̲i̲o̲n̲

         a)  The detailed definition of single engineering functions
             depends on actual hardware and software, however,
             main functions s described below shall be covered
             and guidelines be followed.

         b)  Supervisor engineering command control may only
             be used for control of on-line equipment.(Refer
             3.2.4.1.1.13).

         c)  Engineering functions shall exist to switch between
             hardware unis whenever dualization is used to obtain
             required availability.

         d)  Engineering functions shall exist to control external
             lines as required by line interface equipment.
              Examples are line speed, code, start/stop bits
             control.

         e)  Engineering funcion shall exist to conduct online
             and offline tests by software or other means as
             needed to meet availability requirement.

         f)  Engineering function shall exist to control load
             of software from online and offline media to facilitate
             fast restart infailure cases and load of new software
             transported to site as required for initialization
             and restart (see 3.2.8).



3.2.4.6.3    H̲/̲W̲ ̲C̲o̲n̲f̲i̲g̲u̲r̲a̲t̲i̲o̲n̲ ̲S̲t̲a̲t̲u̲s̲ ̲D̲i̲s̲p̲l̲a̲y̲

         As a basis for execution of engineering functions the
         following status information shll be displayed at VDUs
         and/or display-panels:

         -   switching status of redundant equipment on crate-level
             (refer to 3.2.4.5.2.c)

         -   status of line interface equipment with regard
             to parameters controllable via engineering functions
             (refer to 3.2.4