…02…CPS/SDS/001

…02…SRA/810430…02……02…
CAMPS
 SYSTEM
 DESIGN
 SPECIFICATION
…02…ISSUE
 1…02…CAMPS









                 T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲



     5.3  DISTRIBUTION, MONITORING & TEST (DM&T)
          DESIGN ................................... 
         201
       5.3.1  General .............................. 
       201
       5.3.2  Distribution & Monitoring Equipment/
              Facilities ........................... 
             201
         5.3.2.1  DEC - Category 1 ................. 
         209
         5.3.2.2  DEC - Category 2 ................. 
         211
         5.3.2.3  DEC - Category 3 ................. 
         213
         5.3.2.4  DEC - Category 4 ................. 
         215
         5.3.2.5  DEC - Category 5 ................. 
         217

       5.3.3  Test of Distribution Equipment ....... 
       217
       5.3.4  Appendix A ........................... 
       217



5.3      D̲I̲S̲T̲R̲I̲B̲U̲T̲I̲O̲N̲,̲ ̲M̲O̲N̲I̲T̲O̲R̲I̲N̲G̲ ̲&̲ ̲T̲E̲S̲T̲ ̲(̲D̲M̲&̲T̲)̲ ̲D̲E̲S̲I̲G̲N̲



5.3.1    G̲e̲n̲e̲r̲a̲l̲

         The aim of this section is to explain the design of
         the DM&T equipment/facilities as implemented in the
         present CAMPS H/W configuration shown in fig. 5.3.1-1.



5.3.2    D̲i̲s̲t̲r̲i̲b̲u̲t̲i̲o̲n̲ ̲&̲ ̲M̲o̲n̲i̲t̲o̲r̲i̲n̲g̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲/̲F̲a̲c̲i̲l̲i̲t̲i̲e̲s̲

         The present CAMPS system interfaces to terminals and
         external circuits, both in a collocated and a remote
         configuration.

         The main difference between a collocated and a remote
         configuration is that data exchange in the remote configuration
         involves VF-Modem links carrying encrypted data (crypto/modem
         link).

         The types of terminals in collocated configurations
         are:

         -   Visual Display Unit                  (VDU)
         -   Medium Speed Teleprinter             (MSP)
         -   Low Speed Channel Device (i.e TTY)   (LSC)
         -   Optical Character Reader             (OCR)
         -   Paper Tape Puncher                   (PTP)
         -   Paper Tape Reader                    (PTR)

         The remote terminal configuration is only applicable
         to a subset of these namely:

         -   VDU
         -   MSP

         Furthermore, the remote terminal concept involves a
         statistical multiplexing/demultiplexing system minimizing
         the number of crypto/modem links.

         The types of external circuits in collocated configurations
         are:



         -   NICS/TARE
         -   SCARS
         -   CCIS

         The remote external circuits configuration is only
         applicable to NICS TARE.

         Terminals and external circuits, collocated or remote,
         are connected to CAMPS via the Distribution Equipment.
         The path for data exchange between CAMPS and one collocated/remote
         terminal type or one collocated/remote external circuit
         type will in the following be referenced to as a Data
         Exchange Channel (DEC).

         A DEC contains distribution equipment and a line terminating
         unit.

         Two types of line terminating units exist

         -   Line terminating unit of the LTU type (I/O BUS
             I/F)

         -   Line terminating units of the LTUX type (TDX BUS
             I/F)

         Common to all DECs is the electrical interface specification
         between a line terminating unit and its associated
         distribution equipment. This I/F conforms to the CCITT
         V24/V28 recommendations. To adapt this internal standard
         interface to the various interface requirements of
         the terminals and external circuits, collocated or
         remote, three main types of distribution equipment
         are involved:

         -   Optical link distribution

         -   Low level V24/V28 distribution

         -   Statistical mux/demux distribution

         5 categories of DECs are implemented to satisfy interface
         and security requirements when connecting terminals
         and external circuits to CAMPS. These are as shown
         in fig. 5.3.2-1.

         The line termination modules are placed within CAMPS
         in either a TDX CRATE ASSEMBLY shown in fig. 5.3.2-2
         or a CHANNEL UNIT ASSEMBLY shown in fig. 5.3.2-3.



         Some of the modules of the Distribution Equipment are
         also placed in either a TDX crate assembly or a Channel
         Unit assembly.


















































          FIGURE 5.3.1-1…01…CAMPS H/W CONFIGURATION

















































        FIGURE 5.3.2-1…01…DATA EXHANGE CHANNEL MATRIX

















































                      FIGURE 5.3.2-2
                    TDX Crate Assembly

















































           FIGURE 5.3.2-3…01…CHANNEL UNIT ASSEMBLY

















































TABLE 5.3.2-4…01…Data Exchange Channel, Category Characteristics


         In the following paragraphs each DEC category is described.
         Furthermore, monitoring facilities for each category
         will be indicated.

         Where applicable the mechanical dimensions of the involved
         modules will be referenced to as:

         -   Standard CR80S module, or
         -   Standard CR80D front crate module, or
         -   Standard CR80D rear crate module

         For further explanation of the CR80S and CR80D mechanics
         please refer to section 5.5.



5.3.2.1  D̲E̲C̲ ̲-̲ ̲C̲a̲t̲e̲g̲o̲r̲y̲ ̲1̲

         Fig. 5.3.2.1-1 shows the cat. 1 DEC along with facilities
         to monitor the DEC traffic. The OPTO Transceivers perform
         the conversion from the V24/V28 circuitry signals to
         serial opto signals and vice versa.

         The V24 circuits transferred via the distribution equipment
         and the baud rates are as shown in table 5.3.2-4. For
         explanation of the V24 circuit numbers please refer
         to Appendix A (subsection 5.3.4).

         The DEC is formed by one LTUX channel and the associated
         distribution equipment.

         The LTUX is a standard CR80S module placed in a TDX
         crate as shown in fig. 5.3.2-2. The LTUX is capable
         of handling max. 4 DECs depending on transmission speed
         and protocols. The V24/V28 MONITOR module shown is
         not normally mounted. But when plugged into the TDX
         crate for maintenance purposes it enables monitoring
         of the LTUX V24/V28 signals via Cannon plugs on its
         front panel. The V24/V28 MONITOR module is a standard
         CR80S module providing monitoring access to all 4 V24/V28
         channels of the LTUX.

         The distribution equipment contains a TDX crate mounted
         OPTO TRANSCEIVER, an OPTO cable and a terminal OPTO
         TRANSCEIVER.



















































                     Figure 5.3.2.1-1
            Data Exchange Channel - Category 1


         The TDX crate mounted OPTO TRANSCEIVER is a standard
         CR80S module capable of converting 1 V24/V28 channel
         into 1 optical link signal and vice versa. On the front
         panel are 2 optical link receptacles, one transmit
         and one receive receptacle.

         The OPTO cable is a dual optical mono fiber cable transferring
         optical signals between the two types of opto transceiver.

         The terminal OPTO TRANSCEIVER is capable of converting
         1 V24/V28 channel, coming from the terminal, into 1
         optical link signal and vice versa. The layout allows
         the OPTO TRANSCEIVER to be placed within the terminal.



5.3.2.2  D̲E̲C̲ ̲-̲ ̲C̲a̲t̲e̲g̲o̲r̲y̲ ̲2̲

         The cat. 2 DEC is shown on fig. 5.3.2.2-1. Facilities
         to monitor the DEC traffic are also indicated.

         The cat. 2 DEC consists of 1 LTUX channel and the associated
         distribution equipment.

         The LTUX is a standard CR80S module placed in a TDX
         crate as shown in fig. 5.3.2-2. The LTUX is capable
         of handling max. 4 DECs depending on transmission speed
         and protocols. Towards the low speed channel devices
         the LTUX provides 4 DECs. The V24/V28 MONITOR module
         shown is not normally mounted. But when plugged into
         the TDX crate for maintenance purposes it enables monitoring
         of the LTUX V24/V28 signals via Cannon plugs on its
         front panel. The V24/V28 MONITOR module is a standard
         CR80S module providing monitoring access to all 4 V24/V28
         channels of the LTUX.

         The distribution equipment contains a TDX crate mounted
         V24/V28(L) ADAPTER and a cable connecting the V24/V28(L)
         ADAPTER and the CAMPS V24 Filter Assy. (Internal Distribution
         Frame).

         The V24/V28(L) ADAPTER converts the standard CCITT
         V24/V28 signal levels to low level V24/V28 (V24/V28(L))
         signals and vice versa. These low level signals conform
         with the security requirements specified in CPS/210/SYS/0001
         paragraph 3.4.5.1.


















































   Figure 5.3.2.2-1…01…Data Exchange Channel - Category 2


         The V24 signalling circuits and baud rates used are
         as shown in table 5.3.2-4. For explanation of the V24
         circuit numbers please refer to sub section 5.3.4 (Appendix
         A).

         The V24/V28(L) ADAPTER is a standard CR80S module capable
         of converting V24/V28 lines to low level lines and
         vice versa. The front panel holds CANNON plugs for
         connecting cables between the module and the V24 Filter
         Assy.



5.3.2.3  D̲E̲C̲ ̲-̲ ̲C̲a̲t̲e̲g̲o̲r̲y̲ ̲3̲

         The cat. 3 DEC is shown on fig. 5.3.2.3-1. Monitoring
         facilities concerning this DEC are also shown.

         The cat. 3 DEC consists of 1 LTUX channel and the associated
         distribution equipment.

         The LTUX is a standard CR80S module placed in a TDX
         crate as shown in fig. 5.3.2-2. The LTUX is capable
         of handling max. 4 DECs depending on transmission speed
         and protocols. The V24/V28 MONITOR module shown is
         not normally mounted. But when plugged into the TDX
         crate for maintenance purposes it enables monitoring
         of the LTUX V24/V28 signals via Cannon plugs on its
         front panel. The V24/V28 MONITOR module is a standard
         CR80S module providing monitoring access to all 4 V24/V28
         channels of the LTUX.

         The distribution equipment consists of a V24/V28 ADAPTER,
         a line rack mounted statistical multiplexer/demultiplexer,
         a V24/V28(L) ADAPTER, a CRYPTO/MODEM block, and another
         statistical multiplexer/demultiplexer.

         The statistical multiplexer/demultiplexer performs
         multiplexing of 8 V24/V28 channels into 1 V24/V28 channel,
         and demultiplexing of 1 V24/V28 channel back to 8 V24/V28
         channels. This multiplexing/demultiplexing effieciently
         reduces the number of crypto- and VF-modem equipment
         and modem links involved in remote terminal communication.
         Mechanical dimensions are TBD.


















































   Figure 5.3.2.3-1…01…Data Exchange Channel - Category 3


         The V24/V28(L) ADAPTER converts the standard CCITT
         V24/V28 signal levels to low level V24/V28 (V24/V28(L))
         signals and vice versa. These low level signals conform
         with the security requirements specified in CPS/210/SYS/0001
         paragraph 3.4.5.1.

         The V24/V28(L) ADAPTER is a standard CR80S module capable
         of converting V24/V28 lines to low level lines and
         vice versa. The front panel holds CANNON plugs for
         connecting cables between the module and the V24 Filter
         Assy.

         The CRYPTO/MODEM link of the DEC connects the remote
         terminal location and the CAMPS main site location
         via a VF channel carrying encrypted data.

         The V24 signalling circuits and baud rates used are
         as shown in table 5.3.2-4. For explanation of the V24
         circuit numbers please refer to sub-section 5.3.4 (Appendix
         A).



5.3.2.4  D̲E̲C̲ ̲-̲ ̲C̲a̲t̲e̲g̲o̲r̲y̲ ̲4̲

         The cat. 4 DEC is shown on fig. 5.3.2.4-1, and it consists
         of 1 LTU channel and the associated distribution equipment.

         The V24/V28 MONITOR PANEL shown is no part of the DEC,
         but illustrates the possibility of monitoring access
         to the LTU V24/V28 channel via the LIA-L. The V24/V28
         MONITOR PANEL is a standard 19 inch rack mounted module.

         The LTU is a standard CR80D front crate module placed
         in the Channel Unit assembly as shown in fig. 5.3.2-3.
         The LTU is capable of handling 1 or 2 DECs.

         The distribution equipment consists of a LIA-L module
         and a cable for connection between the LIA-L and the
         IDF.

         The LIA-L (Line Interface Adapter - Low level) is a
         standard CR80D rear crate module placed in the Channel
         Unit Assembly. The LIA-L converts the V28 signal levels
         to low level (V28(L)) signals according to the security
         requirements specified in CPS/210/SYS/0001 paragrapth
         3.4.5.1.




















































   Figure 5.3.2.4-1…01…Data Exchange Channel - Category 4


         The LIA-L is capable of converting 2 V24/V28 channels
         into two low level V24/V28(L) channels and vice versa.
         The V24/V28(L) channels are connected to the IDF via
         two LIA-L front panel mounted 25p Cannon plugs and
         a cable. Two more 25p Cannon plugs are mounted on the
         front panel of the LIA-L. These are via cables connected
         to the back of the V24/V28 MONITORING PANEL. This provides
         monitoring access to the V24/V28 channels between the
         LTU and the LIA-L via 25p Cannon plugs on the front
         of the monitoring panel.

         Applicable V24 circuits and baud rates are shown in
         table 5.3.2-4. For explanation of the V24 circuit numbers
         please refer to section 5.3.4 (Appendix A).



5.3.2.5  D̲E̲C̲ ̲-̲ ̲C̲a̲t̲e̲g̲o̲r̲y̲ ̲5̲

         This DEC cat. 5 is shown on fig. 5.3.2.5-1.

         The DEC implementation conforms with the description
         of the cat. 4 DEC the only difference being the number
         of circuits in the V24/V28 channel. The DEC cat. 5
         shows an extended number of V24 control circuits to
         enable the DEC to control and monitor a CRYPTO link
         in case of a connected remote NICS TARE.

         Applied V24 circuits and baud rates are as shown in
         table 5.3.2-4. For explanation of the V24 Circuit numbers
         please refer to section 5.3.4 (Appendix A).



5.3.3    T̲e̲s̲t̲ ̲o̲f̲ ̲D̲i̲s̲t̲r̲i̲b̲u̲t̲i̲o̲n̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲

         As described in the previous sections a Data Exchange
         Channel (DEC), no matter of which category, is implemented
         using the same basic structure, the line termination
         unit/distribution equipment structure.

         When troubleshooting a DEC, two immediate test points
         are available. The first is the connection between
         the DEC and the connected Terminal/external equipment.
         Disconnecting and testing the DEC at this point, by
         means of test equipment and off-line M&D S/W, the error
         can be related to either the terminal/external equipment
         or the DEC. This test can be performed without opening
         the CAMPS Tempest enclosure.



         The second test point is the monitoring facility. To
         access this it will be necessary to open the tempest
         enclosure. Testing communication at this point relates
         an error to either the line termination unit or the
         distribution equipment.

         More specific test methods and strategies are described
         in the CAMPS MAINTENANCE PLAN CPS/PLN/006, section
         2.4.4.3. 



5.3.4    A̲P̲P̲E̲N̲D̲I̲X̲ ̲A̲

         Definition of applied V24 circuits.

         (Ref. table 5.3.2-4)

         C̲i̲r̲c̲u̲i̲t̲ ̲1̲0̲1̲ ̲-̲ ̲P̲r̲o̲t̲e̲c̲t̲i̲v̲e̲ ̲G̲r̲o̲u̲n̲d̲ ̲o̲r̲ ̲E̲a̲r̲t̲h̲

         This conductor shall be electrically bonded to the
         machine or equipment frame. It may be further connected
         to external grounds as required by applicable regulations.

         C̲i̲r̲c̲u̲i̲t̲ ̲1̲0̲2̲ ̲-̲ ̲S̲i̲g̲n̲a̲l̲ ̲G̲r̲o̲u̲n̲d̲ ̲o̲r̲ ̲C̲o̲m̲m̲o̲n̲ ̲R̲e̲t̲u̲r̲n̲

         This conductor establishes the signal common reference
         potential for unbalanced interchange circuits in the
         100-series between data circuit-terminating equipment
         and data terminal equipment.

         C̲i̲r̲c̲u̲i̲t̲ ̲1̲0̲3̲ ̲-̲ ̲T̲r̲a̲n̲s̲m̲i̲t̲t̲e̲d̲ ̲D̲a̲t̲a̲

         Direction: TO data circuit-terminating equipment.

         The data signals originated by the data terminal equipment,
         to be transmitted via the data channel to one or more
         remote data stations, are transferred on this circuit
         to the data circuit-terminating equipment.

         C̲i̲r̲c̲u̲i̲t̲ ̲1̲0̲4̲ ̲-̲ ̲R̲e̲c̲e̲i̲v̲e̲d̲ ̲D̲a̲t̲a̲

         Direction: FROM data circuit-terminating equipment

         The data signals generated by the data circuit-terminating
         equipment, in response to data channel line signals
         received from a remote data station, are transferred
         on this circuit to the data terminal equipment.


         C̲i̲r̲c̲u̲i̲t̲ ̲1̲0̲5̲ ̲-̲ ̲R̲e̲q̲u̲e̲s̲t̲ ̲t̲o̲ ̲S̲e̲n̲d̲

         Direction: TO data circuit-terminating equipment

         Signals on this circuit control the data channel transmit
         function of the data circuitterminating equipment

         The ON condition causes the data circuit-terminating
         equipment to assume the data channel transmit mode.

         The OFF condition causes the data circuit-terminating
         equipment to assume the data channel non-transmit mode,
         when all data transferred on Circuit 103 (Transmitted
         data) have been transmitted.

         C̲i̲r̲c̲u̲i̲t̲ ̲1̲0̲6̲ ̲-̲ ̲R̲e̲a̲d̲y̲ ̲f̲o̲r̲ ̲S̲e̲n̲d̲i̲n̲g̲

         Direction: FROM data circuit-terminating equipment

         Signals on this circuit indicate whether the data circuit-terminating
         equipment is conditioned to transmit data on the data
         channel.

         The ON condition indicates that the data circuit-terminating
         equipment is conditioned to transmit data on the data
         channel.

         The OFF condition indicates that the data circuit-terminating
         equipment is not prepared to transmit data on the data
         channel.

         C̲i̲r̲c̲u̲i̲t̲ ̲1̲0̲7̲ ̲-̲ ̲D̲a̲t̲a̲ ̲S̲e̲t̲ ̲R̲e̲a̲d̲y̲

         Direction: FROM data circuit-terminating equipment

         Signals on this circuit indicate whether the data circuit-terminating
         equipment is ready to operate.

         The ON condition indicates that the signal-conversion
         or similar equipment is connected to the line and that
         data circuit-terminating equipment is ready to exchange
         further control signals with the data terminal equipment
         to initiate the exchange of data.

         The OFF condition indicates that the data circuit-terminating
         equipment is not ready to operate.



         C̲i̲r̲c̲u̲i̲t̲ ̲1̲0̲8̲/̲2̲ ̲-̲ ̲D̲a̲t̲a̲ ̲T̲e̲r̲m̲i̲n̲a̲l̲ ̲R̲e̲a̲d̲y̲

         Direction: TO data circuit-terminating equipment

         Signals on this circuit control switching of the signal-conversion
         or similar equipment to or from the line.

         The ON condition, indicating that the data terminal
         equipment is ready to operate, prepares the data circuit-terminating
         equipment to connect the signal conversion or similar
         equipment to the line and maintains this connection
         after it has been established by supplementary means.

         The data terminal equipment is permitted to present
         the ON condition on Circuit 108/2 whenever it is ready
         to transmit or receive data.

         The OFF condition causes the data circuit-terminating
         equipment to remove the signal-conversion or similar
         equipment from the line, when the transmission to line
         of all data previously transferred on Circuit 103 has
         been completed.

         C̲i̲r̲c̲u̲i̲t̲ ̲1̲0̲9̲ ̲-̲ ̲D̲a̲t̲a̲ ̲C̲h̲a̲n̲n̲e̲l̲ ̲R̲e̲c̲e̲i̲v̲e̲d̲ ̲L̲i̲n̲e̲ ̲S̲i̲g̲n̲a̲l̲ ̲D̲e̲t̲e̲c̲t̲o̲r̲

         Direction: FROM data circuit-terminating equipment.

         Signals on this circuit indicate whether the received
         data channel line signal is within appropriate limits,
         as specified in the relevant recommendation for data
         circuit-terminating equipment.

         The ON condition indicates that the received signal
         is within appropriate limits.

         The OFF condition indicates that the received signal
         is not within appropriate limits.

         C̲i̲r̲c̲u̲i̲t̲ ̲1̲1̲3̲ ̲-̲ ̲T̲r̲a̲n̲s̲m̲i̲t̲t̲e̲r̲ ̲S̲i̲g̲n̲a̲l̲ ̲E̲l̲e̲m̲e̲n̲t̲ ̲T̲i̲m̲i̲n̲g̲ ̲(̲D̲a̲t̲a̲
         ̲T̲e̲r̲m̲i̲n̲a̲l̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲ ̲S̲o̲u̲r̲c̲e̲)̲

         Direction: TO data circuit-terminating equipment.

         Signals on this circuit provide the data circuit-terminating
         equipment with signal element timing information.



         The condition on this circuit shall be ON and OFF for
         nominally equal periods of time, and the transition
         from ON to OFF condition shall nominally indicate the
         centre of each signal element on Circuit 103 (Transmitted
         data).

         C̲i̲r̲c̲u̲i̲t̲ ̲1̲1̲4̲ ̲-̲ ̲T̲r̲a̲n̲s̲m̲i̲t̲t̲e̲r̲ ̲S̲i̲g̲n̲a̲l̲ ̲E̲l̲e̲m̲e̲n̲t̲ ̲T̲i̲m̲i̲n̲g̲ ̲(̲D̲a̲t̲a̲
         ̲C̲i̲r̲c̲u̲i̲t̲-̲T̲e̲r̲m̲i̲n̲a̲t̲i̲n̲g̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲ ̲S̲o̲u̲r̲c̲e̲)̲

         Direction: FROM data circuit-terminating Equipment

         Signals on this circuit provide the data terminal equipment
         with signal element timing information.

         The condition on this circuit shall be ON and OFF for
         nominally equal periods of time. The data terminal
         equipment shall present a data signal on Circuit 103
         (Transmitted data) in which the transitions between
         signal elements nominally occur at the time of the
         transitions from OFF to ON condition of Circuit 114.

         C̲i̲r̲c̲u̲i̲t̲ ̲1̲1̲5̲ ̲-̲ ̲R̲e̲c̲e̲i̲v̲e̲r̲ ̲S̲i̲g̲n̲a̲l̲ ̲E̲l̲e̲m̲e̲n̲t̲ ̲T̲i̲m̲i̲n̲g̲ ̲(̲D̲a̲t̲a̲
         ̲C̲i̲r̲c̲u̲i̲t̲-̲T̲e̲r̲m̲i̲n̲a̲t̲i̲n̲g̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲ ̲S̲o̲u̲r̲c̲e̲

         Direction: FROM data circuit-terminating equipment.

         Signals on this circuit provide the data terminal equipment
         with signal element timing information.

         The condition of this circuit shall be ON and OFF for
         nominally equal periods of time, and a transition from
         ON to OFF condition shall nominally indicate the centre
         of each signal element on Circuit 104 (Received data).



















































   Figure 5.3.2.5-1…01…Data Exchange Channel - Category 5