WangText




                     -  #  -…01……01…

                          


        T̲E̲C̲H̲N̲I̲C̲A̲L̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲S̲ ̲A̲N̲D̲ ̲S̲P̲E̲C̲I̲F̲I̲C̲A̲T̲I̲O̲N̲S̲



         The Optical Modem Equipment to be supplied under this
         contract shall meet the specifications and requirments
         specified in this appendix:



                 1̲ ̲ ̲G̲E̲N̲E̲R̲A̲L̲ ̲S̲P̲E̲C̲I̲F̲I̲C̲A̲T̲I̲O̲N̲



1.1      The CAMPS Optical Communication System (OCS) shall
         establish a full duplex asynchronous link between data
         terminal equipment (peripherals) and the data terminal
         equipment (host computer) or a synchronous/ asynchrounous
         link between two host computers.

         The OCS includes the following items:

         a)  A CAMAC module to be connected in the host computer
             end.

         b)  A built-in module to be placed into existing terminals
             (Visual Display Unit (VDU), Medium speed Printer
             (MSP))

             A stand-alone module is a built-in module placed
             in a separate box to be placed by the terminal.

         c)  Dual monofiber opto-cable to interconnect the modules.

         d)  Optical connectors to use for termination of the
             OPTO cables. The connectors fit the connectors
             mounted on the modules.



1.2      Transmission length capability shall be mininum 2 km.



1.3      Optical modules shall be mutually compatible, so that
         any combination of modems and cable length provide
         an OCS operating within specified limits without any
         adjustments necessary, provided the cable length is
         below specified max. value.

         The optical modems shall exhibit high reliability and
         long MTBF, thus excluding the use of injection laser.


1.4      Bit error rate shall be better than 10xx -9 for all
         combinations of baud rates and lengths specified.



1.5      The optical link shall continuously be monitored and
         fatal erros (e.g. line break, loss of synchronization)
         shall be indicated by light indicators.






                      2̲ ̲ ̲E̲N̲V̲I̲R̲O̲N̲M̲E̲N̲T̲



         The OCS-items shall operate within the specified limits
         under environmental conditions as specified below:

2.1      Ambient temperature range: 0 to 50 deg.c.

         Change: max. 10 deg.C per hour.



2.2      Humidity: 40 - 90 per cent relative humidity (% RH),
         non-condensing.

         Change: Max. 6% RH per hour.



2.3      Altitude: Sea level to 2000 meter.



2.4      D̲U̲S̲T̲,̲ ̲F̲U̲M̲E̲S̲ 

         The equipment shall be able to operate continuously
         and with normal scheduled preventive maintenance in
         the following air environment:



         a)  A̲i̲r̲ ̲C̲l̲e̲a̲n̲n̲e̲s̲s̲

             Particle Size      Max. Allowable Number
             (̲m̲i̲c̲r̲o̲n̲s̲)̲          (̲P̲a̲r̲t̲i̲c̲l̲e̲s̲/̲C̲u̲b̲i̲c̲m̲e̲t̲e̲r̲)̲

             greater than 5     4 x 10…0e…5…0f…
             greater than 1.5   4 x 10…0e…6…0f…
             greater than 1     4 x 10…0e…7…0f…

         b)  F̲u̲m̲e̲s̲

             Sulphur dioxide max. 14 ppm.





                3̲ ̲ ̲P̲H̲Y̲S̲I̲C̲A̲L̲ ̲S̲P̲E̲C̲I̲F̲I̲C̲A̲T̲I̲O̲N̲S̲



3.1      S̲I̲N̲G̲L̲E̲ ̲C̲H̲A̲N̲N̲E̲L̲ ̲B̲U̲I̲L̲T̲-̲I̲N̲ ̲M̲O̲D̲U̲L̲E̲

         The single channel built-in module is designed to be
         used in the terminal end of the optical communication
         system (OCS).

         The module shall be used for TEMPEST terminals.

         The connection to the terminal may be implemented in
         two basic different ways:

         a)  BUILT-IN (B-I): The module is mounted inside the
             TEMPEST shield of the terminal. Installation of
             the module in the TEMPEST terminal shall be performed
             in a way, which does not disturb the TEMPEST integrity
             and performance of the terminal.

             It shall be possible to mount the built-in module
             enclosed in the Delta Data System Corporation VDU,
             type 7260T.

         b)  STAND-ALONE (S-A): The module is placed in a box,
             which is mounted on the outer surface of the TEMPEST
             terminal or on wall/floor close to the terminal.
             The assembly formed by the module and the box shall
             be certified to meet the TEMPEST requirements NACSEM
             5100.

             The signal interface connection between the S-A
             and the terminal is passed by the normal signal
             connector of the terminal.



         This section specifies the module used in both ways.
         Requirements specific for only the one application
         are marked B-I resp. S-A.

         Requirements specific for the module to be mounted
         in the DELTA 7260T are marked 7260T.



3.1.1    S̲i̲z̲e̲

         The requirements for available space shall be minimize
         to ease installation.

         Max. dimensions:

         7260T: 242 x 216 x 30 mm (H x D x W, exclusive
                  connectors)

         S-A:   362 x 318 x 80 mm



3.1.2    P̲o̲w̲e̲r̲ ̲I̲n̲p̲u̲t̲

         Power input characteristics will for B-I modules show
         variations depending on the actual terminal.

         The specification of the S-A below are the basic power
         input requirements.

         7260T:  a)   The module is supplied with filtered transformed
                     power through the power filters of the
                     terminal.

                 b)  Voltage: Single phase, 110 VAC
                     Voltage tolerances: + 20%/-18%

                 c)  Frequency:

                     Nominal value: 50 Hz
                     Tolerances:    +10/-10%

                 d)  Harmonic distortion:

                     Max. 5%



                 e)  Transients:

                         Non-repetive impulsive interference
                         with a magnitude not to exceed 250
                         volts, pulse rise and fall times not
                         faster than 10 microseconds and a total
                         duration of maximum 1 millisecond.
                         The available impulse energy at the
                         equipment power inlet shall not exceed
                         5J.

                 f)  Power consumption: less than 0.25 ampere
                     at 110 VAC.

         S-A:    a)  If filtered power is no available, the
                     power line filter is included in the box.

                 b)  Voltage: Single phase

                     b1) Some equipment will be operated at
                         240 VAC

                     b2) Most equipment will be operated at
                         220 VAC

                     Voltage tolerances: +10%/-15%

                 c)  Frequency:

                     Nominal value: 50 Hz
                     Tolerances:    +10%-10%

                 d)  Harmonic distortion:

                     Max. 5%

                 e)  Transients:

                         Non-repetive impulsive interference
                         with a magnitude not to exceed 500
                         volts, pulse rise and fall times not
                         faster than 10 microseconds and a total
                         duration of maximum 1 millisecond.
                         The available impulse energy at the
                         equipment power inlet shall not exceed
                         5J.





3.1.3    M̲e̲c̲h̲a̲n̲i̲c̲a̲l̲ ̲C̲o̲n̲s̲t̲r̲u̲c̲t̲i̲o̲n̲

         S-A:    a)   OPTO-cables are fed through a waveguide/port
                     on the rear/bottom of the box to the optical
                     connectors.

                 b)  V24-connectors are fed thorugh a waveguide/port
                     on the rear/bottom of the box to the V24
                     connector.

                 c)  Power cables

                     c1) Power line filter not include in box:

                         Cables are fed through a waveguide/port
                         on the rear/bottom of the box to the
                         power connector of the module

                     c2) Power line filter incuded in box:

                         Cables are fed to a power connector
                         on the rear/bottom of the box.

                 d)  The waveguide/port construction mentioned
                     in paras a), b), and c) above shall allow
                     the cables to be disconnected from the
                     box, without cutting connectors, e.g. a
                     plate carrying the waveguide screwed on
                     the box.



3.1.4    L̲i̲g̲h̲t̲ ̲I̲n̲d̲i̲c̲a̲t̲o̲r̲s̲

         The colour of the light indicators will be PWR-Green,
         RCVL-Red, RTS-Yellow, CTS-Yellow, and SYNC-Red.

         B-I/7260T:  Light indicators shall be visible on the
                     module, close to the upper edge.

         S-A:        Light indicators shall be visible on the
                     front/upper panel to allow inspecton without
                     disassembly of the box.



3.1.5    S̲i̲g̲n̲a̲l̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲ ̲t̲o̲ ̲D̲a̲t̲a̲ ̲T̲e̲r̲m̲i̲n̲a̲l̲





3.1.5.1  The electrical interface specification shall comply
         with CCITT V 28 modified  by MIL-STD-188C.

         Max. transmission speed is 9600 bps.

         The module shall interface to Data Terminal Equipment
         (DTE).



3.1.5.2  The built-in module shall provide the following circuits:

         CCITT, V24

         (101)     Protective Ground                 (PG)
         (102)     Signal Ground                     (SG)
         (103)     Transmitted Data                  (TD)
         (104)     Received Data                     (RD)
         (105)     Request to Send                   (RTS)
         (106)     Clear to Send                     (CTS)
         (107)     Data Set Ready                    (DSR)
         (108)     Data Term. Ready                  (DTR)
         (109)     Carrier Detect                    Not supported
                                                     on printer
         (Special) Spare Conrol Input


3.5.1.3  C̲o̲n̲n̲e̲c̲t̲o̲r̲ ̲T̲y̲p̲e̲

         7260T:  a)  BERG type connector to interface the internal
                     BERG type connector in the 7260T

                 b)  PIN allocation:

                     Pin No.      Circuit

                     1            + 12 VDC
                     2            RD (104)
                     3            DSR (107)
                     4            TD (103)
                     5            DTR (108)
                     6            RTS (105)
                     7            CTS (106)
                     8            code pos.
                     9            SG (102)

         B-I/S-A:    a) CANNON type db 25s or equivalent

                     b) Pin allocation: RS 232 standard





3.2      S̲I̲N̲G̲L̲E̲ ̲C̲H̲A̲N̲N̲E̲L̲ ̲C̲A̲M̲A̲C̲ ̲M̲O̲D̲U̲L̲E̲ ̲A̲N̲D̲ ̲T̲R̲A̲N̲S̲F̲O̲R̲M̲E̲R̲ ̲M̲O̲D̲U̲L̲E̲

         This version shall be housed in a 1m, 5u CAMAC module.
         CR specifies the mechanical dimensions and characteristics
         of the module.

         The front panel is designed by Versitron.

         The mechanical items (front panel, runners, tec.) are
         supplied to Versitron by CR A/S for assembly by Versitron.



3.2.1    All signal and power connections shall be via an edge
         connector on the rear of the module. Connector and
         pin allocation are specified by CR A/S.



3.2.2    P̲o̲w̲e̲r̲ ̲S̲o̲u̲r̲c̲e̲s̲

         The module can be powered by two alternative power
         sources. The source is selected by straps on the module
         or an equivalent method.

         a)  DC-power

             available regulated voltages:

             a1) +  5v
             a2) + 12v
             a3) - 12v

         b)  AC-power

             b1) The module is powered by 2 x 9 VAC through
                 3 connectors of the edge connector.

             b2) A transformer module converts to 2 x 9 VAC
                 nominal.

                 The transformer unit is supplied by Versitron.

                 b.2.1   The transformer module shall be able
                         to supply 8 CAMAC-modules

                 b.2.2   The transformer module diagram and
                         mechanical lay-out are specified by
                         CR.



                 b.2.3   Power input to the transformer unit:

                         220 VAC + 10 %/- 15 %
                            50 HZ  + 10 %/- 10 %

                 b.2.4   Harmonic distortion: Max. 5 per cent



3.2.3    Indicators and optical connectors shall be mounted
         on the front panel, indicators in the lower end. The
         colour of the Indicators shall be specified by CR.
         See paragraph 3.1.4.



3.2.4    S̲i̲g̲n̲a̲l̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲



3.2.4.1  The electrical interface specification shall comply
         with CCITT V28 modified by MIL-STD-188c. The module
         shall be able to interface standard V28 circuits.

         Transmisison speed:

         a)  Asynchronous: Max. 19.2 kbps

         b)  Synchronous:  2.4, 4.8, 9.6, 19.2 and 38.4 kbps.

         The module shall interface both to DTE and DCE. The
         normal interface is to DTE. The cross-connection cable
         required for providing the DCE interface will be supplied
         by CR.





3.2.4.1  The CAMAC module shall provide the following circuits:


                                            Pin No.

         (102)       Signal Ground          A/B 27
         (103)       Transmitted Data       A 33
         (104)       Received Data          B 33
         (105)       Request to Send        A 32
         (106)       Clear to Send          B 31
         (107)       Data Set Ready         A 29
         (108)       Data Term. Ready       B 32
         (109)       Carrier Detect         A 31
         (114)       Transmiss. clock       B 28 *1
         (115)       Receive Clock          A 30
         Special     Spare Control Input    B 29 *2
         Special     Aprae Control Output   B 30 *2

         Notes:      1) Selectable with strap on the module

                     2) Can be disconnected by removal of strap
                          on board



3.2.5    C̲o̲n̲f̲i̲g̲u̲r̲a̲t̲i̲o̲n̲s̲

         The following configurations shall be possible:

         a)  CAMAC to Built-in module, Asynchronous transmission,
             both modules are DTE.

         b)  CAMAC to CAMAC, asynchronous transmission, all
             combinations of DCE/DTE.

         c)  CAMAC to CAMAC, synchronous transmission, both
             are DCE or one DTE, provided local modem is Master
             and remote modem is slave. (see attached drawing.



3.3      O̲P̲T̲I̲C̲A̲L̲ ̲L̲I̲N̲K̲

         Specificaton of optical signal in opto line:

         a)  Optical Wavelength: 820 nm

         b)  Optical Bandwidth: 10 to 15 MHZ/km

         c)  Launched transmit power (min): 80 microwatts



         d)  Optical receive power (min.) 200 nanowatts

         e)  Optical path loss. Max allowed value including
             one splice: 23 db

         f)  Optical coding: Manchester



3.4      O̲P̲T̲I̲C̲A̲L̲ ̲C̲A̲B̲L̲E̲ ̲A̲N̲D̲ ̲C̲O̲N̲N̲E̲C̲T̲O̲R̲S̲

         a)  The optical cable shall be dual core monofiber.
             GALITE type 50 205D or equivalent is acceptable.

         b)  The optical connectors for mounting on the opto
             cable are SMA Type.



3.5      T̲E̲R̲M̲I̲N̲A̲T̲I̲O̲N̲ ̲K̲I̲T̲

         The termination kit consists of:



         Non-expendable items:

         Quantity    Total to be Item
         per kit     Supplied
          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

          1           3          Instructions
          1           2          Wire Stripper
          2          10          Wire Cutter, small
          2          10          Wire Cutter, Large
          1           2          Glass Clever
          1           5          Polishing Fixture
          1           2          Polishing Plate
          1           2          Heat Gun
          1           2          Crimp Tool
          1           2          Crimp Die
          1           2          Cable Holder
          1           2          Flashlight
          1           2          7x Magnifier
          1           2          Retaining ring insertion tool
          3           6          Syringe
         12          24          Shoulder Screws
         12          24          Cable Clamps
          5           6          Squeeze Bottles
          5          10          Bottles or Cans



         Expendable Items:

         20         600          Single Edge Blades
         50        1500          Lapping film, assorted
          4.6       138 m        Heat shrign tubing, assorted
          1 box       2 boxes    Toothpicks
          1 box       2 boxes    Wood Applicators
         40        1200          Alum Weighing Dishes
          1 set       3 sets     2 part epoxy
                     10 l        Acetone
                      7 l        Buffer stripper
         as req                  Kimwipes

         Last three items local purchase.