DataMuseum.dk

Presents historical artifacts from the history of:

CR80 Wang WCS documentation floppies

This is an automatic "excavation" of a thematic subset of
artifacts from Datamuseum.dk's BitArchive.

See our Wiki for more about CR80 Wang WCS documentation floppies

Excavated with: AutoArchaeologist - Free & Open Source Software.


top - download

⟦856aeca78⟧ Wang Wps File

    Length: 79738 (0x1377a)
    Types: Wang Wps File
    Notes: CPS/AUX/068    (Site 16)  
    Names: »3796A «

Derivation

└─⟦f30773e96⟧ Bits:30006207 8" Wang WCS floppy, CR 0323A
    └─ ⟦this⟧ »3796A « 

WangText

5…00……00……00……00…B…0a……00……00…B…0b…B…0d…B…0f…A…09…< ;…0a…;…0f…; :…08…:…0a…:…0f…:…05…9…0a…9…0e…9 8…09…8…0b…8…00…8
8 7…08…7…0d…7…02…7…05…6…0b…6…01…6…05…5…0b…5…00…5…05…4…0a…4…86…1                                             …02…           …02…   …02…   

      3796A/ktd…02…CPS/AUX/068

…02…NPP/831221…02……02…#
CAMPS INSTALLATION PROCEDURES
SITE 16…02…Issue 1…02… CAMPS














                 CAMPS INSTALLATION PROCEDURES
                 SITE 16  


                 CPS/AUX/068














                 Niels Peder Pedersen




                 Kurt Nybroe-Nielsen







                 SHAPE (4), KNN, KM, HAU, BHB, IJO, NPP, 
                 Conf. Mgmt., QA, PAB, CLA (2)















                          Install. Mgr    831221


         Issue 2    



         831221




    3796A/rt       …02… CPS/AUX/068

 …02… NPP/831221…02……02…ii
CAMPS INSTALLATION PROCEDURES
SITE 16…02… Issue 1…02… CAMPS












        830606                  All      Issue 1 of Document

        831221                  All      Issue 2
                                         (according to CAMPS
                                          log 1530).




   3796A/rt       …02… CPS/AUX/068

CAMPS INSTALLATION PROCEDURES …02… NPP/831221…02…   iii
SITE 16
…02… Issue 1…02… CAMPS





                                      T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲




     TITLE PAGE  ....................................  
      i
     REVISION RECORD ................................  
     ii
     TABLE OF CONTENTS ..............................  iii
     ABBREVIATIONS ..................................  
     vi

     1 INTRODUCTION .................................  
       1 
       1.1 SCOPE ....................................  
           1 
       1.2 DOCUMENT FORMAT ..........................  
           1 
       1.3 REFERENCES ...............................  
           2 

     2 MAIN SITE INSTALLATION PREPARATIONS ..........  
       4 
       2.1 SHIPMENT OF EQUIPMENT ....................  
           4 
         2.1.1 Disassembly and Packing ..............  
               4 
         2.1.2 Transportation to Site ...............  
               7 
         2.1.3 Receipt of Equipment at the Main Site   
               8 
           2.1.3.1 Receipt ..........................  
                   8 
           2.1.3.2 Incoming Inventory/Inspection ....  
                   9 
           2.1.3.3 Distribution of Equipment ........  
                   9 

       2.2 PREPARATION OF INSTALLATION 
           AT THE MAIN SITE .........................  11
           
         2.2.1 Preparations by CR ...................  11
               
         2.2.2 Preparations by Site .................  12
               
       2.3 INSTALLATION OPERATIONS ..................  14
           

     3 INSTRUCTIONS TO THE MAIN SITE ................  18
       
       3.1 TRANSPORTATION TO INSTALLATION SHAPE .....  18
           
       3.2 INSTALLATION PREPARATIONS AND SUPPORT ....  18
           
       3.3 SHIPMENT CONTAINERS ......................  20
           

     4 TOOLS AND TEST EQUIPMENT .....................  20
       

     5 INSTALLATION OF MAIN SITE EQUIPMENT ..........  23
       
       5.1 GENERAL ..................................  23
           
       5.2 MECHANICAL RACK ASSEMBLY .................  24
           
         5.2.1 Unpacking of Racks ...................  24
               
         5.2.2 Transportation to Installation Site. .  26
               
         5.2.3 Removal of Upper Crates and M-Fans ...  26
               
         5.2.4 Removal of Main Switches .............  28
               
         5.2.5 Mounting of Levellers ................  28
               
         5.2.6 Mounting of Gaskets ..................  28
               
         5.2.7 Levelling and Bolting of Racks .......  29
               
         5.2.8 Inspection/Repair of Gaskets .........  29
               



    3796A/rt       …02… CPS/AUX/068

…02… NPP/831221…02……02…iv
CAMPS INSTALLATION PROCEDURES
SITE 16…02… Issue 1…02… CAMPS





         5.2.9 Mounting of Power Line Filters
               Rack A, B and E ......................  30
               
         5.2.10 Remounting of Upper Crates and D-Fans  30
                
         5.2.11 Remounting of Main Switches .........  30
                

       5.3 INSTALLATION OF EXTERNAL POWER CABLES
           AND MOUNTING OF CONDUITS .................  31
           
         5.3.1 Power Cables Rack A ..................  31
               
         5.3.2 Power Cables Rack B ..................  31
               
         5.3.3 Power Cables Rack E ..................  31
               

       5.4 INSTALLATION OF EXTERNAL SIGNAL CABLES AND
           MOUNTING OF CONDUITS AT RACK C, D, AND F .  32
           
         5.4.1 Rack D, Sup./Maint./User Pos. Cables .  32
               
         5.4.2 Cable Bunch Rack C to Rack D .........  33
               
         5.4.3 Rack F (LSM/Other Cables) ............  33
               

       5.5 REMOUNTING OF RACKS ......................  34
           
         5.5.1 Mounting of Disk Drives ..............  34
               
         5.5.2 Mounting of Floppy Disk Station ......  34
               
         5.5.3 Mounting of Modules ..................  35
               

       5.6 INSTALLATION AND TERMINATION OF INTERNAL
           SIGNAL CABLES ............................  35
           
         5.6.1 Internal Signal Cables ...............  35
               

       5.7 TERMINATION OF EXTERNAL SIGNAL CABLES ....  57
           

       5.8 CONNECTION OF INTERNAL POWER CABLES ......  66
           

       5.9 POWER UP AND CHECK OUT ...................  73
           
         5.9.1 Groundings ...........................  73
               
         5.9.2 CAMPS PDB ............................  73
               
         5.9.3 Disk Drives...........................  75
               
         5.9.4 Main Switch Rack A Switch 2 ..........  77
               
         5.9.5 Main Switch Rack B Switch 2 ..........  79
               
         5.9.6 Main Switch Rack B Switch 1 ..........  79
               
         5.9.7 Main Switch Rack C Switch 2 ..........  80
               
         5.9.8 Main Switch Rack D Switch 1 ..........  81
               
         5.9.9 Main Switch Rack E Switch 1 ..........  81
         
         5.9.10 Main Switch Rack D Switch 2 .........  82
                
         5.9.11 Main Switch Rack F Switch 2 .........  82
                
         5.9.12 Main Switch Rack E Switch 1 .........  82
                
         5.9.13 Main Switch Rack F Switch 1 .........  83
                
         5.9.14 Turn On .............................  83
                
         5.9.15 Verify Supply Voltage on PU Crates ..  83
                
         5.9.16 Verify Supply Voltage on CU Crate ...  84
                




    3796A/rt       …02… CPS/AUX/068

 …02… NPP/831221 …02…v
CAMPS INSTALLATION PROCEDURES
SITE 16…02… Issue 1…02… CAMPS





       5.10 INSPECTION OF SWITCH SETTINGS AND STATUS
            LEDS ....................................  84
         5.10.1  Switch Settings ....................  85
         5.10.2  LED Indicators .....................  85
       5.11 INSTALLATION OF DELTA VDU ...............  90
         5.11.1  Power Plug Connections .............  90
         5.11.2  Termination of Opto Cables .........  90
         5.11.3  Mounting of Keyboard and Keys ......  91

       5.12  INSTALLATION OF TRACOR MSP .............  92
         5.12.1  Power Plug Connections .............  92
         5.12.2  Termination of Opto Cables .........  92
         5.12.3  Installation of Paper and Ribbon ...  92
         5.12.4  Installation of Piston Spring ......  92

       5.13  INSTALLATION OF PTP/PTR ................  93

       5.14  TEST OF SUP/USER TERMINALS .............  94
         5.14.1  Test of Delta VDU ..................  94
         5.14.2  Operational Test ...................  95
         5.14.3  Test of Tracor MSP .................  95
         5.14.4  Operational Test ...................  96

       5.15  TEST OF PTP/PTR ........................  96

       5.16  H/W TEST PROCESSOR/LINE TERM. UNITS ....  96
         5.16.1  PU #1(CU/TDX #2 Functional Test ....  97
         5.16.2  Watchdog Processor Functional Test .  97

     5.17  INVENTORY CHECK ..........................  97




    3796A/ktd      …02… CPS/AUX/068

 …02… NPP/831221…02……02…vi
CAMPS INSTALLATION PROCEDURES
SITE 16…02… Issue 1…02… CAMPS





                      A̲B̲B̲R̲E̲V̲I̲A̲T̲I̲O̲N̲S̲



         A̲B̲B̲R̲E̲V̲I̲A̲T̲I̲O̲N̲S̲:̲

         ATBB           As To Be Built
         BPJF           Black Patch Jack Field
         CAMPS          Computer Aided Message Processing System
         CR             Christian Rovsing A/S
         CRT            Remote Terminals
         DIAG           Diagram 
         Doc            Document
         DWG            Drawing
         EMI            Electromagnetic Interference
         H/W            Hardware
         IDF            Intermediate Distribution Frame
         ILLUS          Illustrations
         J-Box          Junction Box
         LED            Light Emitting Diode
         LIA-N          Line Interface Adapte
         LSM            Low Speed Medium
         LTU            Line Termination Unit
         LTUX-S         Line Termination Unit/TDX Bus
         L/L ADP        Low Level Adapter
         MMD            Mini Module Drive
         MSP            Medium Speed Printer
         M&D            Maintenance and Diagnostic
         PDB            Power Distribution Board
         PDP            Power Distribution Panel
         PLF            Power Line Filter
         PTP            Paper Tape Puncher
         PTR            Paper Tape Reader
         STAT.MUX       Statistical Multiplexer
         Sup.Term.      Supervisor Terminal
         TARE           Telegraph Automatic Relay Equipment
         TDX            Telecommunication Data Exchange
         VDU            Visual Display Unit
         W-NUMBER       Cable Identification Number




                     1  I̲N̲T̲R̲O̲D̲U̲C̲T̲I̲O̲N̲



1.1      S̲C̲O̲P̲E̲

         This document describes how CR will perform the installation
         of the CAMPS equipment and gives instructions to site
         concerning receipt of equipment and arrrangements to
         be made by the site concerning CR's presence during
         the installation.



1.2      D̲O̲C̲U̲M̲E̲N̲T̲ ̲F̲O̲R̲M̲A̲T̲

         a)  The document is structured in the following sections:

             -   Section 1: Introduction
             -   Section 2: Installation Preparations
             -   Section 3: Instruction to Main Site
             -   Section 4: Installation Tools and Test
                            Equipment
             -   Section 5: Installation of Main Site Equipment

         b)  Section 2 provides a short description of how the
             equipment is packed and indicates to the site the
             size of arriving shipment in form of quantity,
             size, and weight of containers in the shipment.
             A description of the preparations to be made by
             CR and the Site is also provided in this section.

         c)  Section 3 contains the instructions to Main Site
             concerning the coming installation.

         d)  Section 4 lists the tools and test equipment used
             during installation.



         e)  Section 5 contains a step-by-step instruction of
             how to install and interconnect the CAMPS Main
             Site assemblies with reference to the As-To-Be-Built
             drawings. Procedures for power up and installation
             check-out are included.

         f)  Section 5  will be updated after the installation
             have been accomplished and incorporated in the
             installation manual to be delivered after provisonal
             site acceptance.



1.3      R̲E̲F̲E̲R̲E̲N̲C̲E̲S̲

         1.  CAMPS Hardware Assembly
             Breakdown/Hardware Tree
             Doc. No. CPS/SDS/017

         2.  CAMPS Site Level Maintenance Manual
             Doc. No. CPS/TCM/005

         3.  Inventory List
             Doc. No. CPS/AUX/054

         4.  OPTO-Cable Termination Procedure
             Doc. No. CPS/TCN/066

         5.  Site Survey Procedure and Checklist

         6.  Factory Acceptance Procedure
             Doc. No. CPS/TPR/001

         7.  CAMPS USER MANUAL
             Doc. No. CPS/OPM/001



         8.  CAMPS TRANSPORTATION PLAN
             Doc. No. CPS/PLN/007

         9.  ATBB DRAWINGS
             Doc. No. PAB/CPS/ATB/016

         10. CIVIL WORKS REQUIREMENTS SITE 16
             Doc. No. PAB/CPS/CWR/016

         11. CAMPS ACCEPTANCE PLAN
             Doc. No. CPS/PLN/012



          2  M̲A̲I̲N̲ ̲S̲I̲T̲E̲ ̲I̲N̲S̲T̲A̲L̲L̲A̲T̲I̲O̲N̲ ̲P̲R̲E̲P̲A̲R̲A̲T̲I̲O̲N̲S̲



2.1      S̲H̲I̲P̲M̲E̲N̲T̲ ̲O̲F̲ ̲E̲Q̲U̲I̲P̲M̲E̲N̲T̲



2.1.1    D̲i̲s̲a̲s̲s̲e̲m̲b̲l̲y̲ ̲a̲n̲d̲ ̲P̲a̲c̲k̲i̲n̲g̲

         The CAMPS equipment for the Main Site will be shipped
         to site disassembled and packed as follows:

         -   Rack Assemblies (ABC, DEF) are seperated in individual
             racks and packed in a wooden container.

         -   Disk Units, Power Linefilters and Modules are removed
             from the racks and shipped in their own containers.

         -   Cables between racks are generally shipped as part
             of one of the racks.

         -   Terminal equipment (VDU, MSP, PTP/PTR) and auxiliary
             equipment (tables, storage cabinet) are shipped
             in their own containers.

         -   Site spare parts are individually packed and are
             shipped together with the main equipment.

         Above packing scheme will result in the shipment composition
         described in Table 2.1. The table lists quantity of
         containers and packed weight and cubage of each container,
         together with the total quantity, cubage, and weight
         of the shipment. The logistic data given is to be used
         by the site for preparation of the receival and for
         providing temporary storage area.




S̲i̲t̲e̲ ̲1̲6̲

                                                Total      
  Total 
Item            Item  Size of Cont. Container   Packed     Container
D̲e̲s̲c̲r̲i̲p̲t̲i̲o̲n̲ ̲ ̲ ̲ ̲ ̲ ̲Q̲t̲y̲ ̲ ̲ ̲W̲x̲D̲x̲H̲ ̲(̲c̲m̲)̲ ̲ ̲ ̲ ̲ ̲Q̲t̲y̲ ̲ ̲ ̲ ̲ ̲W̲e̲i̲g̲h̲t̲ ̲(̲k̲g̲)̲ ̲ ̲C̲u̲b̲a̲g̲e̲
 ̲(̲c̲b̲m̲)̲

Rack A           1   72x126x192      1        300           1.74
Rack B           1   72x126x192      1        295           1.74
Rack C           1   72x126x192      1        315           1.74
Rack D           1   72x126x192      1        305           1.74
Rack E           1   72x126x192      1        280           1.74
Rack F           1   72x126x192      1        285           1.74
MMD DISK DRIVE   2   63x95x62        2        185           0.74
SMD DISK DRIVE   1   63x95x62        1         92           0.37
MSP              9   65x74x39        9        333           1.69
VDU             43   65x80x55       43       1850          12.3
PTP/PTR          1   63x69x62        1         43           0.27
CR80S, 1M MODULE     93             29x38x35  16             79      0.68
CR80S, 2M MODULE      8             29x38x35   1              4      0.04
CR80S, PSU           11             29x38x35  11             62      0.47
CR80M, 1M MODULE     23             54x32x61                   
CR80M, 2M MODULE      1             54x32x61   …0e…3             40      0.32…0f…
CR80M, PSU            6             68x68x48   3             44      0.67
FD STATION       1   67x85x50        1         27           0.28
PLF              3   30x48x32        2         26           0.10
DISK PACK        6   48x50x25        6         33           0.36
TERMINAL TABLES 15   121x81x10      15        780           1.50
CABLES           1   54x32x61        1         10           0.09
STORAGE CABINET  1   60x65x210       1        …0f…103           0.85…0e…
                     100x130x2       ̲1̲         ̲ ̲ ̲            ̲ ̲ ̲ 

MAIN SITE TOTAL                    123      5,491          31.17
MAIN SITE SPARES/DOC.                         1̲4̲            1̲5̲9̲      1̲.̲3̲6̲

                                   1̲3̲7̲      5̲,̲6̲5̲0̲          3̲2̲.̲5̲3̲




                       Table 2.1 (sheet 1)
                         Logistic Data…01…


S̲p̲a̲r̲e̲s̲,̲ ̲T̲e̲s̲t̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲ ̲&̲ ̲D̲o̲c̲u̲m̲e̲n̲t̲s̲


                                                 Total        Total
 
Item             Item  Size of Cont. Container   Packed     Container
D̲e̲s̲c̲r̲i̲p̲t̲i̲o̲n̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲Q̲t̲y̲ ̲ ̲ ̲W̲x̲D̲x̲H̲ ̲(̲c̲m̲)̲ ̲ ̲ ̲ ̲ ̲Q̲t̲y̲ ̲ ̲ ̲ ̲ ̲W̲e̲i̲g̲h̲t̲ ̲(̲k̲g̲)̲ ̲ ̲C̲u̲b̲a̲g̲e̲
 ̲(̲c̲b̲m̲)̲

CR80S, 1U MODULE 1    29x38x35        1          1          0.04
CR80S, 6U MODULE 1    29x38x35        1          6          0.04
CR80M, 1U MODULE 6    54x32x61        …0f…1         13          0.09…0e…
CR80M, 1U ADAPTER     3               54x32x61
CR80M, 4U MODULE 1    68x68x48        1          8          0.22
CR80S, FAN UNIT  1    20x55x40        1          7          0.04
CR80M, FAN UNIT  1    67x85x50        1         12          0.28 
KIT FOR VDU      1
MSP UNIT         1
P/N: 54147711    1
-  : 54152501    1
-  : 54275307    1
-  : 54275710    1
-  : 54277306    1
-  : 54277713    1    54x32x61        1         20          0.09
PSU FOR FD       1
PCB SA800-2      1
LOGIC MODULE     1
PUNCH LOGIC      1
POS LOGIC        1
READ HEAD ASSY   1
PUNCH MOTOR      1
MODEM UNIT       1
OSCILLOSCOPE     1    42x78x32        1         11          0.10
COMTESTER        1    42x53x23        1          6          0.05
FIELD TEST UNIT  1    50x40x25        1          8          0.05
ALIGNMENT DISK   1    48x50x25        1          7          0.06
DOCUMENTS        -    54x32x61        ̲3̲         ̲6̲0̲          0̲.̲3̲0̲

                                     14        159          1.36






                       Table 2.1 (sheet 2)
                          Logistic Data


2.1.2    T̲r̲a̲n̲s̲p̲o̲r̲t̲a̲t̲i̲o̲n̲ ̲t̲o̲ ̲S̲i̲t̲e̲

         The CAMPS equipment will be carried to site by truck.
         The equipment will be loaded at CR's plant in Copenhagen
         and transported directly to site without any transshipment.

         CR will use an experienced transportation company for
         the conveyence.

         The truck used will be an aircushion vehicle type with
         the dimensions indicated in Table 2.2.

         Truck and load data include all main site equipment.










                              T̲r̲u̲c̲k̲              T̲r̲u̲c̲k̲ ̲+̲ ̲l̲o̲a̲d̲
 

         Weight             9 tons             15.0 tons
         Size (m)           3.75Hx2.50Wx9.75L           
         Axle load, front    2 tons             6.2 tons
         Axle load, rear     5 tons            10.3 tons












                Table 2.2…01…Truck Dimensions


2.1.3    R̲e̲c̲e̲i̲p̲t̲ ̲o̲f̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲ ̲a̲t̲ ̲t̲h̲e̲ ̲M̲a̲i̲n̲ ̲S̲i̲t̲e̲



2.1.3.1  R̲e̲c̲e̲i̲p̲t̲

         a)  The receipt of the equipment at the main site will
             be performed by CR's installation team. The installation
             team or a CR representative will arrive one day
             in advance of the truck carrying the equipment.
             The transportation company (2 men) will assist
             CR in moving equipment to the installation area.

         b)  The shipment will be notified according to the
             transportation plan as follows:

             1.  CR will request a customs form 302, 30 days
                 in advance of the shipment.

             2.  SHAPE will reforward the request to the site
                 who will issue the form 302 and submit it to
                 SHAPE.

             3.  SHAPE will submit the completed form 302 together
                 with an authorization to ship as scheduled
                 in the notification telex per 1. above.

             4.  CR will send a notice of shipment per telex
                 to SHAPE at the day of the shipment, with the
                 arrival day at site of the equipment.

         c)  The shipment will be accompanied by the following
             shipping documents according to ref 1:

             -   A complete set of packing lists
             -   Proforma Invoice
             -   Shipping Letter
             -   Customs Form 302
             -   Authorization to Ship telex

             All containers are marked with a package number.
             A set of above documents is enclosed in container
             No. 1 and a set is attached to the outside of container
             No. 1.



2.1.3.2  I̲n̲c̲o̲m̲i̲n̲g̲ ̲I̲n̲v̲e̲n̲t̲o̲r̲y̲/̲I̲n̲s̲p̲e̲c̲t̲i̲o̲n̲

         1)  CR will perform an incoming inventory of the equipment
             according to the packing lists found in container
             No. 1.

         2)  Before the containers are moved to the installation
             site, the containers will be inspected for any
             visual damages.

         3)  The results of the above mentioned 1) and 2) will
             be recorded and a copy will be given to the transportation
             company.



2.1.3.3  D̲i̲s̲t̲r̲i̲b̲u̲t̲i̲o̲n̲ ̲o̲f̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲

         The transportation company will distribute the received
         equipment as follows:

         1)  U̲s̲e̲r̲ ̲T̲e̲r̲m̲i̲n̲a̲l̲s̲

             The 38 VDU and 6 MSP user terminals are distributed
             to the respective installation sites.

             The terminals are unpacked and left on the installation
             sites (tables) and the empties are removed.

         2)  S̲u̲p̲p̲/̲M̲a̲i̲n̲t̲.̲ ̲T̲e̲r̲m̲i̲n̲a̲l̲s̲

             The 5 VDU and 3 MSP supp/maint terminals are stored
             in the CAMPS equipment room and left unpacked.

         3)  R̲a̲c̲k̲s̲/̲S̲t̲o̲r̲a̲g̲e̲ ̲C̲a̲b̲i̲n̲e̲t̲

             The 6 EMI racks and the storage cabinet are moved
             into the CAMPS equipment room.

         4)  P̲T̲P̲/̲P̲T̲R̲

             The PTP/PTR is stored in the encryption area and
             left unpacked on the allocated table.



         5)  T̲e̲r̲m̲i̲n̲a̲l̲ ̲T̲a̲b̲l̲e̲s̲

             7 terminal tables are stored in the CAMPS equipment
             area.

             8 terminal tables for the user termials are stored
             according to instructions from H/N.

         6)  O̲t̲h̲e̲r̲ ̲S̲e̲p̲a̲r̲a̲t̲e̲l̲y̲ ̲P̲a̲c̲k̲e̲d̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲

             Other separately packed equipment such as cables,
             disk drives, modules, spares, etc, are stored in
             the temporary storage area. Ref. site survey report.





2.2      P̲R̲E̲P̲A̲R̲A̲T̲I̲O̲N̲ ̲O̲F̲ ̲I̲N̲S̲T̲A̲L̲L̲A̲T̲I̲O̲N̲ ̲A̲T̲ ̲T̲H̲E̲ ̲M̲A̲I̲N̲ ̲S̲I̲T̲E̲



2.2.1    P̲r̲e̲p̲a̲r̲a̲t̲i̲o̲n̲s̲ ̲b̲y̲ ̲C̲R̲

         a)  The CR installation team plans to arrive one day
             in advance of the equipment. Prior to the planned
             arrival, the officer in charge of CAMPS is informed
             by telex.

         b)  Upon arrival, the local CAMPS officer in charge
             will give a briefing, addressing the following
             subjects:

             -   Access to site and house rules

             -   Location of applicable areas such as storage
                 area, parking and unloading area, CAMPS equipment
                 area, etc.

             -   The support requested by contractor, ref. 2.2.2.

             -   Introduction of the installation team to relevant
                 local personnel.

             -   Information regarding local facilities such
                 as cafeteria, telephones, medical aid, etc.

         c)  The installation team will present the planned
             major steps of the installation efforts. Ref section
             5: Step-by-step procedures.

         d)  Full identification of the delivery team (transportation
             Company) including names and truck licence will
             be provided at least ten days prior to delivery.

         e)  Names and clearances of the potential installation
             team will be provided one month before start of
             the installation.




2.2.2    P̲r̲e̲p̲a̲r̲a̲t̲i̲o̲n̲s̲ ̲b̲y̲ ̲S̲i̲t̲e̲

         a)  The CAMPS equipment rooms are prepared for installation
             of the equipment according to the civil works requirements
             and this is verified at the site verification inspection
             which is scheduled to take place 1 month prior
             to start of installation.

         b)  Arrangements to be made for CR's presence at site
             are described in section 3.

             These arrangements have been assessed during the
             site surveys and are to be discussed and finalized
             during the site verification meetings.




















































                        Figure 2.1
                  Installation Schedule


2.3      I̲N̲S̲T̲A̲L̲L̲A̲T̲I̲O̲N̲ ̲O̲P̲E̲R̲A̲T̲I̲O̲N̲S̲

         The installation of a complete CAMPS system requires
         that the installation operations are performed in a
         certain sequence.

         Figure 2.1 shows the installation effort structured
         in operations and with a time schedule for each operation.

         A brief summary of the operations are given below:

         1   T̲r̲a̲v̲e̲l̲t̲i̲m̲e̲

         2   A̲r̲r̲i̲v̲a̲l̲/̲I̲n̲t̲r̲o̲d̲u̲c̲t̲i̲o̲n̲

         3   M̲e̲c̲h̲a̲n̲i̲c̲a̲l̲ ̲R̲a̲c̲k̲ ̲A̲s̲s̲e̲m̲b̲l̲y̲

             The equipment racks (Rack A-F) will after arrival
             to the site be moved to the CAMPS equipment area
             and unpacked. The racks will be aligned and bolted
             together to form the 3-bay computer unit (Rack
             A-B-C) and the 3-bay line termination unit (Rack
             D-E-F).

             The Freq. Stabilizer will be moved to its position
             and integrated.

             All terminals and the terminal tables will be distributed
             to their respective installation sites.



         4   E̲x̲t̲e̲r̲n̲a̲l̲ ̲P̲o̲w̲e̲r̲ ̲C̲a̲b̲l̲e̲s̲

             The power cables coming from the CAMPS power distribution
             board will be terminated in the Frequency Stabilizer
             and the power line filters of Rack A, B, and E.

         5   E̲x̲t̲e̲r̲n̲a̲l̲ ̲S̲i̲g̲n̲a̲l̲ ̲C̲a̲b̲l̲e̲s̲

             Opto fibre cables coming from the user terminals
             entering rack D through the CR installed conduits
             will be distributed to their respective termination
             points in racks C, D, and E.

             Cables from rack D to the supervisory and maintenance
             positions will be installed.

             All metallic cables coming from the customer delivered
             LSM terminals as well as the metallic cables coming
             from other connections (e.g. SCARS, CCIS, etc)
             will be installed in the filter box of rack F through
             the CR installed metallic conduit.

             Interrack cables between the computer and line
             termination units will be installed.

         6   I̲n̲t̲e̲r̲n̲a̲l̲ ̲S̲i̲g̲n̲a̲l̲ ̲C̲a̲b̲l̲e̲s̲

             All internal signal cables in the computer and
             line termination units, dismounted during the transportation,
             will be reinstalled. Cables not dismounted will
             be checked for being properly connected.



         7   T̲e̲r̲m̲i̲n̲a̲t̲i̲o̲n̲ ̲o̲f̲ ̲E̲x̲t̲e̲r̲n̲a̲l̲ ̲S̲i̲g̲n̲a̲l̲ ̲C̲a̲b̲l̲e̲s̲

             All opto fibre cables to be connected on front
             of the line termination unit (racks D and E) will
             be terminated with special opto connectors.

             Metallic interface cables to be connected in the
             filterbox of rack F are to be terminated by customer.

         8   I̲n̲t̲e̲r̲n̲a̲l̲ ̲P̲o̲w̲e̲r̲ ̲C̲a̲b̲l̲e̲s̲

             All internal power cables dismounted during transportation
             will be reinstalled in the computer and line termination
             unit.

         9   I̲n̲s̲t̲a̲l̲l̲a̲t̲i̲o̲n̲ ̲o̲f̲ ̲T̲e̲r̲m̲i̲n̲a̲l̲s̲

             All opto fibre cables for the User-, Maintenance-,
             and Supervisory Terminals will be terminated with
             special opto connectors. Before connecting the
             cables to the optical modem boards, the cables
             will be checked for supplying enough light emission.

             The terminals will be powered up and tested locally.

         10  P̲o̲w̲e̲r̲ ̲U̲p̲ ̲a̲n̲d̲ ̲T̲e̲s̲t̲

             Powering up the computer and line termination units
             will be performed in a certain sequence in order
             to check that power groups and phases are correctly
             distributed.

             To ensure that the hardware will be able to support
             all required CAMPS functions, a functional test
             will be carried out according to the specified
             site verification procedure.



         11  T̲e̲s̲t̲ ̲o̲f̲ ̲T̲e̲r̲m̲i̲n̲a̲l̲s̲

             All installed terminals including the PTP/PTR will
             be tested according to the site acceptance test
             procedure.

         12  I̲n̲v̲e̲n̲t̲o̲r̲y̲ ̲C̲h̲e̲c̲k̲

             The CR installation team will conduct an inventory
             check of all delivered CAMPS equipment, including
             documents, test equipment and spare parts.

             This inventory check will be witnessed by the customer.

         13  C̲O̲M̲S̲E̲C̲ ̲T̲e̲s̲t̲

             The CR installation team will run the system for
             the one day test in the CAMPS room.

             COMSEC will be trained in running the user terminals
             for further COMSEC test of these terminals.

         14  P̲a̲c̲k̲i̲n̲g̲

             Packing of CR test equipment, cleaning, mounting
             of doors, etc.

         15  T̲r̲a̲v̲e̲l̲t̲i̲m̲e̲






             3  I̲N̲S̲T̲R̲U̲C̲T̲I̲O̲N̲S̲ ̲T̲O̲ ̲T̲H̲E̲ ̲M̲A̲I̲N̲ ̲S̲I̲T̲E̲

         This section contains instructions to the main site
         concerning the site assistance and support to CR during
         installation. As stated above these instructions are
         to be discussed and finalized during the site verification
         meetings.



3.1      T̲R̲A̲N̲S̲P̲O̲R̲T̲A̲T̲I̲O̲N̲ ̲T̲O̲ ̲I̲N̲S̲T̲A̲L̲L̲A̲T̲I̲O̲N̲ ̲S̲I̲T̲E̲

         The equipment will be moved to the installation site
         by the transportation company.

         The site will assist the installation team/CR representative
         as follows:

         -   Escort the transportation personnel.

         -   Indicate the rooms for the 8 CR delivered user
             terminal tables.

         -   Indicate the equipment entry route.

         -   Ensure that the corridors on the entry route are
             cleared.

         -   Ensure that the installation areas are cleared.

         -   Ensure that all site provided terminal tables are
             cleared.

         -   Provide site truck/trolley/pushwaggon as available
             upon request by the transportation company.



3.2      I̲N̲S̲T̲A̲L̲L̲A̲T̲I̲O̲N̲ ̲P̲R̲E̲P̲A̲R̲A̲T̲I̲O̲N̲S̲ ̲A̲N̲D̲ ̲S̲U̲P̲P̲O̲R̲T̲

         The main site is requested to provide the following
         preparations and support prior to or during CR's presence
         at site.

         1   Clear the CAMPS installation area.

         2   Provide/clear tables for the user terminals to
             be installed on customer provided tables.



         3   Clear the equipment entry route from unloading
             area to CAMPS equipment room and from unloading
             area to storage area. The equipment entry route
             is described in the site survey report.

         4    Provide escort of the transportation personnel.

         5   Provide temporary storage area for the equipment
             specified in section 3.1.3. The storage area required
             is specified in the site survey report.

         6   Provide access to site, access badges to be ready
             at arrival of the installation team. Request for
             access and identification credentials of the team
             members will be forwarded through SHAPE.

         7   Provide access to commercial telephone and telex
             allowing for international communication. The use
             to be reimbursed by CR.

         8   Provide access to canteens or messes for CR personnel.

         9   Provide emergency medical aid in case of accidents.

         10  Provide access to reproduction facilities, if available.

         11  Provide office space and furniture including desks,
             chairs, and cabinets for classified and non-classified
             material. Space and furniture for two persons are
             required. Also storage space for tools and test
             equipment (locked room or cabinets) is requested.

         12  Provide site truck/trolley/pushwaggon for transportation
             in the corridors, if available and upon request.

         13  Provide access to a conference room for the introductory
             briefing during the first day.




3.3      S̲H̲I̲P̲M̲E̲N̲T̲ ̲C̲O̲N̲T̲A̲I̲N̲E̲R̲S̲

         As explained in section 2.1, the equipment is shipped
         in several different containers; many of these are
         reusable. It is, therefore, recommended that the site
         stores 1-2 empty containers for later use.

         The installation team will point out the containers
         which are recommended for later use for SHAPE/site
         representatives and the remaining containers will be
         discarded by CR.









         4  I̲N̲S̲T̲A̲L̲L̲A̲T̲I̲O̲N̲ ̲T̲O̲O̲L̲S̲ ̲A̲N̲D̲ ̲T̲E̲S̲T̲ ̲E̲Q̲U̲I̲P̲M̲E̲N̲T̲



         Besides a set of common standard multipurpose hand-tools,
         the below listed tools and test equipments (table 4.1
         and 4.2) will be used during the installation and checkout
         of the CAMPS System.

         Item 1-13 of table 4.1 is used for Opto-Cable termination.

         Test equipment in table 4.2 marked with x) is SHAPE
         Test Equipment.



                             
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                                        REF.
                                                        INSTALL.
I̲T̲E̲M̲ ̲ ̲D̲E̲S̲C̲R̲I̲P̲T̲I̲O̲N̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲P̲A̲R̲A̲.̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

 1  CABLE KNIFE              WEIDMULLER AM. 1           5.11.2
 2  CABLE HAND-STRIPPER      EXELITE # 100/101-S        5.11.2
 3  KEVLAR SCISSORS          EROP 24                    5.11.2
 4  T-STRIPPER               IDEAL 45…0e….…0f…125(YELLOW)       5.11.2
 5  HOT COIL/TRAFO           ITT                        5.11.2
 6  FISH LINE                                           5.11.2
 7  FERULE CRIMPING TOOL     METRIC/AMPHENOL            5.11.2
 8  FIBRE CLEAVER            ITT SAPHIRE BLADE          5.11.2
 9  SNAPPING TOOL            METRIC/VERSITRON(58-59)    5.11.2
10  MICROSCOPE               STRUERS/A23140             5.11.2
11  POLISHING FIXTURE        METRIC/OFTI NR. 1          5.11.2
12  POLISHING FIXTURE        METRIC/OFTI NR. 2          5.11.2
13  HEAT-GUN                 MASTERMITE                 5.11.2
14  CRIMPING TOOL            STOCKO W248                5.3
15  CRIMPING TOOL            STOCKO W236                5.3
16  WRENCH 130mm             BACHO                      5.2
17  WRENCH 150mm             BACHO                      5.2
18  PIPE WRENCH 150mm        BACHO                      5.2
19  DRILLING MACHINE         BACHO                      5.2
20  HIGH SPEED DRILLS        SET 3-16mm                 5.2
21  STANDARD HOLE SAW 48mm   STARRETT                   5.2/5.3
22  STANDARD HOLE SAW 76mm   STARRETT                   5.2/5.3
23  STANDARD HOLE SAW 29mm   STARRETT                   5.2/5.3








 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲





                    TABLE 4.1
               INSTALLATION TOOLS.


                         
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                                        REF.
                                                        INSTALL.
I̲T̲E̲M̲ ̲ ̲D̲E̲S̲C̲R̲I̲P̲T̲I̲O̲N̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲P̲A̲R̲A̲.̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

 1  MULTIMETER               FLUKE DMM 8020A            5.0
 2  DATA COMM. TESTER        TEKTRONIX 834      x)      5.10,
                                                        5.11
 3  TEST SET 921-T           NU DATA 921-T              5.10
                                                        -
                                                        5.17
 4  OPTICAL MULTIMETER       PHONDDYNE 11XE             5.15
 5  OSCILLOSCOPE             TEKTRONIX 465 B    x)      5.0
 6  V24 MONITOR MODULE       CR                         5.14
 7  V2V LOOPBACK ADAPTER     CR                         5.14
 8  LTU LOOPBACK ADAPTER     CR                         5.14
 9  LTUX-S LOOPBACK ADAPTER  CR                         5.14
10  LIA-N LOOPBACK ADAPTER   CR                         5.14



                             NOTE:  All test equipment
                             must be Comsec cleared
                             prior to testing 
                                    of the CAMPS equipment
                             on site.








 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲






                    TABLE 4.2
                 TEST EQUIPMENT.


        5  I̲N̲S̲T̲A̲L̲L̲A̲T̲I̲O̲N̲ ̲O̲F̲ ̲T̲H̲E̲ ̲M̲A̲I̲N̲ ̲S̲I̲T̲E̲ ̲E̲Q̲U̲I̲P̲M̲E̲N̲T̲



5.1      G̲E̲N̲E̲R̲A̲L̲

         The following step by step installation procedure contains
         a detailed instruction set of how to install the CR
         delivered computer racks, frequency stabilizer, TARE
         rack, supervisory positions, maintenance position,
         and user terminals.


         The major tasks of the installation sequence are:

         5.2     Mechanical rack assembly

         5.3     Termination of external power cables and mounting
                 of conduits

         5.4     Installation of external signal cables and
                 mounting of conduits rack C, D and F

         5.5     Remounting of racks

         5.6     Installation and termination of internal signal
                 cables

         5.7     Installation of external signal cables

         5.8     Connection of internal power cables

         5.9     Power up and check out

         5.10    Inspection  of status leds

         5.11    Installation of Delta VDU

         5.12    Installation of Tracor MSP

         5.13    Installation of PTP/PTR

         5.14    Test of Supp/User Terminals

         5.15    Test of PTP/PTR



         5.16    H/W Test Processor/Line term. units

         5.17    Inventory check

         Throughout the installation instruction, references
         are made to the ATBB-Drawings (Doc. PAB/CPS/ATB/016)
         and the CAMPS Hardware Breakdown/Hardware Tree (Doc.
         CPS/SDS/017).



5.2      M̲E̲C̲H̲A̲N̲I̲C̲A̲L̲ ̲R̲A̲C̲K̲ ̲A̲S̲S̲E̲M̲B̲L̲Y̲



5.2.1    U̲n̲p̲a̲c̲k̲i̲n̲g̲ ̲o̲f̲ ̲R̲a̲c̲k̲s̲

         a)  Each of the 6 EMI racks for the main site are separately
             packed in the original wooden container. The racks
             should remain packed during site internal transportation
             and only be unpacked close to the installation
             site, but if the space along the access route is
             limited, the racks can be unpacked before transportation
             to the installation site. The racks are unpacked
             as follows:

         b)  Remove the top cover of the wooden container by
             demounting the 3 ea 1/4 x 2 1/2" bolts on each
             side of the container and the 4 ea 1/2 - 13 x 2"
             bolts, one in each top corner (see Figure 5.2.1).

         c)  The 4 walls of the container are removed by loosening
             the 21 ea 1/4 x 2 1/2" bolts on each short side.

         d)  The rack is bolted to the container bottom in each
             corner by a 1/2 - 13 x 2 1/2" bolt.

         e)  These bolts are removed from under the container
             bottom.






















































                       Figure 5.2.1
              Unpacking Procedure - EMI Rack



5.2.2    T̲r̲a̲n̲s̲p̲o̲r̲t̲a̲t̲i̲o̲n̲ ̲t̲o̲ ̲I̲n̲s̲t̲a̲l̲l̲a̲t̲i̲o̲n̲ ̲S̲i̲t̲e̲

         a)  After unpacking, the front and rear doors of the
             racks must be removed. Check that serial numbers
             in
             the racks correspond to the serial numbers of the
             doors.

         b)  Be careful not to damage the gaskets of the doors.

         c)  Depending on means of transportation, 4 eyelets
             can be mounted in the top of the rack in the position
             of the removed 4 ea 1/2 - 13 x 2" bolts.

         d)  7 terminal tables out of the CR delivered 15 tables
             are moved into the CAMPS area for the maintenance
             and supervisor positions.

         e)  The storage cabinet are moved into the CAMPS area.

         f)  All terminals (25 ea VDU and 9 ea MSP) are distributed
             to their respective installation sites.



5.2.3    R̲e̲m̲o̲v̲a̲l̲ ̲o̲f̲ ̲U̲p̲p̲e̲r̲ ̲C̲r̲a̲t̲e̲s̲ ̲a̲n̲d̲ ̲M̲-̲F̲a̲n̲s̲

         a)  To get access for bolting the single racks into
             3 bay units, the upper crate in rack B, C, E, F
             must be removed.

         b)  Dismount all connected front and rear cables.

         c)  Dismount the power cables on the rear side of the
             M-fan in rack B and C. 
             Loosen the 4  6mm front screws and pull out the
             fan units from the front of the racks.

         d)  Loosen the 8 (M-crate) and 4 (S-crate and stat.
             mux. housing) 6mm front screws and pull out the
             crates by the handles from the front of the racks.
             



















































                       Figure 5.2.2
                   Mounting of Gaskets



5.2.4    R̲e̲m̲o̲v̲a̲l̲ ̲o̲f̲ ̲M̲a̲i̲n̲ ̲S̲w̲i̲t̲c̲h̲e̲s̲

         a)  To get access for bolting the rack in the bottom,
             the main switches in rack B, C, E and F must be
             removed.

         b)  Dismount the power cables and the ground wire on
             the rear side of the main switches.

         c)  Loosen the 4  6mm front screws and pull out the
             main switches from the front of the racks.



5.2.5    M̲o̲u̲n̲t̲i̲n̲g̲ ̲o̲f̲ ̲L̲e̲v̲e̲l̲l̲e̲r̲s̲

         The 4 levellers are mounted from under the racks two
         by two, by tilting the racks (see ATBB drawing 115)

         The levellers are mounted to a distance of 40 mm between
         the bottom of the rack and the floor.



5.2.6    M̲o̲u̲n̲t̲i̲n̲g̲ ̲o̲f̲ ̲G̲a̲s̲k̲e̲t̲s̲

         a)  To secure a correct shielding between the racks,
             gasket strips must be mounted before bolting the
             racks into 3 BAY units. See fig. 5.2.2. The gaskets,
             having pressure sensitive tape adhesive, non-conducting
             type, must be applied at room temperature as follows:

         b)  Clean the mounting surface of old glue, if necessary,
             with a lacquer thinner (acetone or tri-chlorethylene).

         c)  Cut and trim the gasket strip with scissors.

         d)  Peel off the protective paper backing.

         e)  Be sure that the strip is in correct position and
             then press down firmly.

         C̲A̲U̲T̲I̲O̲N̲:    Before tightening the bolts, check that
                     all gaskets between the racks are undamaged.


5.2.7    L̲e̲v̲e̲l̲l̲i̲n̲g̲ ̲a̲n̲d̲ ̲B̲o̲l̲t̲i̲n̲g̲ ̲o̲f̲ ̲R̲a̲c̲k̲s̲

         C̲A̲U̲T̲I̲O̲N̲:  A min. of 50 mm space must be kept               
                                                                    
                                                                    between
                                                                    rack
                                                                    C
                                                                    and
                                                                    rack
                                                                    D.

         a)  The racks are aligned one by one to allow the 1/4-20
             x 7/8 LG bolts to pass through the frames of the
             cabinets.

         b)  The single racks A, B, and C are bolted together
             to form the 3-bay processor rack assembly.

         c)  The single racks D, E and F are bolted together
             to form the 3-bay line termination rack assembly
             (for details ref. ATBB drawings 110/115).

         d)  When all bolts are placed (24 bolts between each
             pair of racks), the bolts are to be tightened on
             opposite sides, alternatively starting at opposite
             ends of the corresponding sides.

         e)  When all bolts have been tightened, the levellers
             must again be adjusted to ensure equal distribution
             of the floor load.

         f)  For adjusting the floor levellers use a pipe wrench.
             Grip around the lower part of the leveller and
             turn it clock wise untill the leveller tightens
             against the floor.

         g)  To check that the racks are true to spirit level,
             use the spirit leveller on top of the racks. 
             Readjust if necessary.



5.2.8    I̲n̲s̲p̲e̲c̲t̲i̲o̲n̲/̲R̲e̲p̲a̲i̲r̲ ̲o̲f̲ ̲G̲a̲s̲k̲e̲t̲s̲

         a)  If by accident parts of the gaskets are damaged
             during transportation, these parts must be replaced
             to encure a correct shielding. The damaged part
             of the gaskets are cut by a knife and removed.

         b)  For mounting details see 5.2.6.





5.2.9    M̲o̲u̲n̲t̲i̲n̲g̲ ̲o̲f̲ ̲P̲o̲w̲e̲r̲ ̲L̲i̲n̲e̲ ̲F̲i̲l̲t̲e̲r̲s̲ ̲R̲a̲c̲k̲ ̲A̲,̲ ̲B̲,̲ ̲a̲n̲d̲ ̲E̲

         a)  Place the power line filter (PLF) over the two
             knockouts in the bottom of the rack (see ATBB drawing
             121 in appendix A)

             The 2 1/2" male adaptor, welded to the PLF, must
             be inserted through the right hand knockout

         b)  Place the tightening nut from the outside of the
             EMI rack.

         c)  Insert the 2 1/2" to 1 1/2" reducing bushing through
             the left hand knockout into the PLF. 

         d)  Mount the 1 1/2" steel tube into the reducing bushing.

         It is very important to the shielding effectiveness
         that the fittings are fully tightened.



5.2.10   R̲e̲m̲o̲u̲n̲t̲i̲n̲g̲ ̲o̲f̲ ̲U̲p̲p̲e̲r̲ ̲C̲r̲a̲t̲e̲s̲ ̲a̲n̲d̲ ̲M̲-̲f̲a̲n̲s̲

         a)  The upper crates of rack B and C are reinserted
             and tightened by the 8  6mm front screws.

         b)  The M-fans of rack B and C are reinserted and tightened
             by the 4  6mm front screws.

         All removed signal cables are to be reinstalled during
         step 5.6. and the power cables during step 5.8.



5.2.11   R̲e̲m̲o̲u̲n̲t̲i̲n̲g̲ ̲o̲f̲ ̲M̲a̲i̲n̲ ̲S̲w̲i̲t̲c̲h̲e̲s̲

         a)  The main switches are reinserted from the front
             of the racks and tightened by the 4  6mm front
             screws.

         b)  Reconnect the ground wires to the panel mounting
             rails.

         The internal power cables are to be reinstalled during
         step 5.8.





5.3      INSTALLATION OF EXTERNAL POWER CABLES AND MOUNTING
         OF C̲O̲N̲D̲U̲I̲T̲S̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲

         C̲A̲U̲T̲I̲O̲N̲

         BEFORE TERMINATING THE EXTERNAL POWER CABLES, ASSURE
         THAT THE MAIN CIRCUIT BREAKER IN THE CAMPS PDB IS DISCONNECTED.



5.3.1    P̲o̲w̲e̲r̲ ̲C̲a̲b̲l̲e̲s̲ ̲R̲a̲c̲k̲ ̲A̲

         a)  Mount the 1 1/2" steel tube through the outer nut
             and washer into the metallic cable duct above rack
             A. Fasten the steel tube by the inner nut from
             inside the cable duct ((see ATBB drawing no. 121).

         b)  The 48 mm metallic conduit is mounted on the fittings
             of the J-box (metallic cable duct) and the power
             line filter and tightened by the 4 clamps.

         c)  Power cables Nos. 1, 2 and 3 together with the
             insolated ground wire are pulled through the cable
             inlet into the power line filter (see ATBB drawing
             121).

         d)  To get access to the PLF, remove the metallic cover
             fastened by 4 screws during transportation. The
             remaining 26 screws are shipped attached to the
             inside wall of PLF. The cables and the ground wire
             are dismantled and terminated with cable shoes.
             For details of the connection to the terminal board
             ref. ATBB drawing 121.



5.3.2    P̲o̲w̲e̲r̲ ̲C̲a̲b̲l̲e̲s̲ ̲R̲a̲c̲k̲ ̲B̲

         Repeat step 5.3.2 for power cables No. 4, 5, 6, and
         the insulated ground wire in racxk B, Power Line Filter.



5.3.3    P̲o̲w̲e̲r̲ ̲C̲a̲b̲l̲e̲s̲ ̲R̲a̲c̲k̲ ̲E̲

         Repeat step 5.3.2 for power cables no. 7, 8, 9, and
         the insulated ground wire in rack E, Power Line Filter.





5.4      I̲N̲S̲T̲A̲L̲L̲A̲T̲I̲O̲N̲ ̲O̲F̲ ̲E̲X̲T̲E̲R̲N̲A̲L̲ ̲S̲I̲G̲N̲A̲L̲ ̲C̲A̲B̲L̲E̲S̲ ̲A̲N̲D̲ ̲M̲O̲U̲N̲T̲I̲N̲G̲
         ̲O̲F̲ ̲C̲O̲N̲D̲U̲I̲T̲S̲ ̲A̲T̲ ̲R̲A̲C̲K̲ ̲C̲,̲ ̲D̲,̲ ̲A̲N̲D̲ ̲F̲



5.4.1    R̲a̲c̲k̲ ̲D̲,̲ ̲S̲u̲p̲.̲/̲M̲a̲i̲n̲t̲.̲/̲U̲s̲e̲r̲ ̲P̲o̲s̲.̲ ̲C̲a̲b̲l̲e̲s̲

         C̲A̲U̲T̲I̲O̲N̲

         Be specially careful when installing the opto fibre
         cables. Min. bending radius is 13 mm.

         a)  Opto cables W811-812/W815-818/W847-848 are installed
             in the PVC duct between rack D and the maint./sup.
             positions in the CAMPS area. See ATBB dwg. 110.

         b)  Mount the fittings for the PVC conduit to the cable
             duct below rack D (see ATBB drawing 116).

         c)  Mount the fittings for the other end of the PVC
             conduit in the left hand knockout of rack D.

         d)  Mount the 75 mm PVC conduit between the cable duct
             and the waveguide.

         e)  Opto cables W811-812/W815-818/W847-848 are pulled
             through the left hand penetration of rack D into
             the internal PVC cable duct.

         f)  Opto cables W811-812 are run through the internal
             cable duct and out through the right hand penetration
             of rack D.

             The opto cables enter rack C together with the
             interrack cables and are terminated on the front
             side of the adapter crate through the cable channel
             assembly. See ATBB dwg. 117.

         g)  Opto cables W815-818/W847-848 are run through the
             internal cable ducts of the line termination racks
             and terminated on the front side of the TDX-crates
             according to ATBB dwg. 125.



         h)  Opto cables W819-846/W849-854/W885-895 coming from
             the user terminals are pulled through the left
             hand bottom penetration and into rack D. The opto
             cables are run through the internal cable ducts
             of the line termination racks and terminated on
             the front of the TDX-crates according to ATBB dwg.
             125.

         i)  Alternative Opto cables are pulled through the
             center bottom penetration of Rack D.  The cables
             will be left in the bottom of the rack for future
             termination.



5.4.2    C̲a̲b̲l̲e̲ ̲B̲u̲n̲c̲h̲ ̲R̲a̲c̲k̲ ̲C̲ ̲t̲o̲ ̲R̲a̲c̲k̲ ̲D̲

         a)  The flexible metallic hose is prefabricated and
             consists of two 2 1/2" steel tubes mounted in each
             end of a length of flexible metallic conduit. The
             cables W904-914 together with OPTO cables W811-812
             are pulled through the metallic hose. 

             The X-net cables W905-908 are placed in a shielding
             of zipper tubing before they are pulled through
             the metallic hose.

         b)  Mount the 2 1/2" steel tubes in the right hand
             penetration of rack C. Tighten fittings by the
             inner nut.

         c)  Repeat step b) for the lefthand penetration of
             rack D. 117.

         d)  The cables are distributed in rack C according
             to ATBB DWG 117.



5.4.3    R̲a̲c̲k̲ ̲F̲ ̲(̲L̲S̲M̲/̲O̲t̲h̲e̲r̲ ̲C̲a̲b̲l̲e̲s̲)̲

         a)  Mount the 2 1/2" steel tube through the outer nut
             into the right hand penetration of rack F and the
             filter box. Tighten the fitting from inside the
             filterbox by the inner nut (see ATBB drawing 116).

         b)  Repeat step a) for the left hand penetration of
             rack F.



         c)  Repeat step a) for the other end of the conduit
             to be mounted in the ferrous duct below rack F
             (see ATBB drawing 110/116).

         d)  Mount the 75 mm metallic conduit on the outside
             of the steel tubes and tighten it by the clamps.

         e)  The low speed medium (LSM) cables W855-878 and
             W814 for the PTP/PTR are pulled through the waveguide
             of the metallic duct, through the right hand pene-
             tration of rack F and into the filter box.

         f)  Other cables:   W731      CCIS
                             W741-744  Colocated TARE
                             W813      OCR

         are pulled through the waveguide of the metallic duct,
         through the left hand penetration of rack F and into
         the filter box.



5.5      R̲E̲M̲O̲U̲N̲T̲I̲N̲G̲ ̲O̲F̲ ̲R̲A̲C̲K̲S̲



5.5.1    M̲o̲u̲n̲t̲i̲n̲g̲ ̲o̲f̲ ̲D̲i̲s̲k̲ ̲D̲r̲i̲v̲e̲s̲

         The 3 separately packed disk drives, 1 MMD for rack
         A, 1 SMD for rack B, and 1 MMD for rack C are unpacked
         and installed according to the instructions in the
         CAMPS 
         Site Level Maintenance Manual Doc. no. CPS/TCM/005.



5.5.2    M̲o̲u̲n̲t̲i̲n̲g̲ ̲o̲f̲ ̲F̲l̲o̲p̲p̲y̲ ̲D̲i̲s̲k̲ ̲S̲t̲a̲t̲i̲o̲n̲

         a)  Remove the front panel located below the watchdog
             crate. (Pos. 1A2A6).

         b)  The floppy disk cabinet containing the two floppy
             disk drives is installed on the two slides.

         c)  The cabinet is locked by mounting and tightening
             the front panel by the 6 6mm screws.





5.5.3    M̲o̲u̲n̲t̲i̲n̲g̲ ̲o̲f̲ ̲M̲o̲d̲u̲l̲e̲s̲

         a)  For correct physical positioning of the separately
             packed modules, refer to the inventory list. The
             inventory list states the serial No. of the unit,
             the crate assy No., the slot No. in the crate and
             the address of the physical position in the system.

         b)  The modules are slid into the print guide and when
             the edge connector of the print has entered the
             connector of the motherboard, the modules are fastened
             by the two fixing screws on the front of the modules.



5.6      I̲N̲S̲T̲A̲L̲L̲A̲T̲I̲O̲N̲ ̲A̲N̲D̲ ̲T̲E̲R̲M̲I̲N̲A̲T̲I̲O̲N̲ ̲O̲F̲ ̲I̲N̲T̲E̲R̲N̲A̲L̲ ̲S̲I̲G̲N̲A̲L̲ ̲C̲A̲B̲L̲E̲S̲



5.6.1    I̲n̲t̲e̲r̲n̲a̲l̲ ̲S̲i̲g̲n̲a̲l̲ ̲C̲a̲b̲l̲e̲s̲

         a)  Tables 5.6.2 through 5.6.19 list all internal signal
             cables in the 3-bay processor rack assembly, and
             the 3-bay line termination rack assembly, e.g.
             also cables not dismounted during transportation.

         b)  The philosophy is to install/terminate or check
             all cables within one crate at a time, starting
             with processor crate assy No. 1.

         c)  The left-hand side of each table states the exact
             location of a specific cable to be connected or
             checked.

         d)  The right-hand side "going to/coming from" indicates
             the termination point for the other end of the
             cable.



         e)  It is recommended, after having connected one cable
             according to the left-hand side of the table, that
             the cable is laid down in the cable trays in the
             direction of the termination point for the other
             end (ref. the right-hand side of the table).

         f)  The termination at the other end of the cable is
             performed when this step in the step-by-step procedure
             is reached.

         g)  The column ILLUS "Cable Illustrations" refers to
             the page No. in the CAMPS HARDWARE BREAKDOWN (CPS/SDS/017)
             showing the physical cables with types of connectors.

         h)  The column DIAG "Cable Diagram" refers to the page
             No. in the CAMPS HARDWARE BREAKDOWN (CPS/SDS/017)
             showing the position of the actual cable in the
             system.

         i)  For details of the interrack cabling see ATBB drawings
             117 and 118.

         W̲A̲R̲N̲I̲N̲G̲:

         D̲I̲S̲C̲O̲N̲              Cable has been disconnected. The
                             cable is not removed from the rack
                             cable tray and the connector is
                             to be found near by the termination
                             point.

         C̲O̲N̲                 Cable has not been disconnected.
                             Check for correct W-number at b̲o̲t̲h̲
                             ̲e̲n̲d̲s̲.

         I̲                   Internal Cable inside the same
                             rack. Cable must be connected/checked
                             at b̲o̲t̲h̲ ̲e̲n̲d̲s̲ according to the right-
                             and left-hand part of the table.

         R̲A̲C̲K̲ ̲(̲A̲,̲ ̲B̲,̲ ̲C̲,̲ ̲e̲t̲c̲) Cable has been withdrawn during
                             transportation and is now found
                             in e.g. rack A.




T̲a̲b̲l̲e̲ ̲5̲.̲6̲.̲2̲





P̲R̲O̲C̲E̲S̲S̲O̲R̲ ̲C̲R̲A̲T̲E̲ ̲A̲S̲S̲Y̲ ̲#̲ ̲1̲ ̲R̲A̲C̲K̲ ̲A̲   

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲

Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ M̲o̲d̲u̲l̲e̲ R̲a̲c̲k̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲
 I̲l̲l̲u̲s̲ D̲i̲a̲g̲ N̲o̲t̲e̲s̲ ̲

W 1  MIA   A1A1A27   J2  CIA-A   B   A2A1A32   J1  
                                                   58    
                                                         65   CON
W 3  CCA   A1A1A23   J1  CCA     B   A2A1A25   J1  
                                                   58    
                                                         65   RACK
                                                              C
                         CCBA    B   A2A4A10   J1  
                                                   58    
                                                         65   RACK
                                                              C
W 4  TIA   A1A1A25   J1  X-NET   A   A1A1A8    J1  
                                                   58    
                                                         65   I
W 5  TIA   A1A1A26   J1  X-NET   A   A1A1A9    J1  
                                                   58    
                                                         65   I
W13  MIA   A1A1A27   J1  WCA     B   A2A4A11   J1  
                                                   60    
                                                         65   CON
W95  TSP   A1A1A24   J1  THERMO  A   A1A1A11   *   
                                                   62    
                                                         68   DISCON
W96  TSP   A1A1A24   J2  THERMO  A   A1A1A10   *   
                                                   62    
                                                         68   DISCON


           *  part of unit



T̲a̲b̲l̲e̲ ̲5̲.̲6̲.̲3̲





X̲-̲N̲E̲T̲ ̲O̲U̲T̲L̲E̲T̲S̲ ̲R̲A̲C̲K̲ ̲A̲              

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ M̲o̲d̲u̲l̲e̲ R̲a̲c̲k̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ I̲l̲l̲u̲s̲
 D̲i̲a̲g̲ N̲o̲t̲e̲s̲

W17 X-NET  A1A1A8   1-2  X-NET   C   A3A3A11  1-2   60   34/65 CON
W18 X-NET  A1A1A8   4-5  X-NET   C   A3A3A11  4-5   60   34/65 CON
W19 X-NET  A1A1A9   1-2  X-NET   C   A3A3A12  1-2   60   34/65 CON
W20 X-NET  A1A1A9   4-5  X-NET   C   A3A3A12  4-5   60   34/65 CON



T̲a̲b̲l̲e̲ ̲5̲.̲6̲.̲4̲





D̲I̲S̲K̲ ̲D̲R̲I̲V̲E̲ ̲R̲A̲C̲K̲ ̲A̲     

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ M̲o̲d̲u̲l̲e̲ R̲a̲c̲k̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ I̲l̲l̲u̲s̲
 D̲i̲a̲g̲ N̲o̲t̲e̲s̲ ̲

W 9 DISK   1A1A5     J3  DCA     B   A2A1A30   J1   59    65  RACK
                                                              B
W12 DISK   1A1A5     J2  DCA     B   A2A1A30   J2   59    65  RACK
                                                              B




T̲a̲b̲l̲e̲ ̲5̲.̲6̲.̲5̲





C̲H̲A̲N̲N̲E̲L̲ ̲U̲N̲I̲T̲ ̲R̲A̲C̲K̲ ̲B̲   

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ M̲o̲d̲u̲l̲e̲ R̲a̲c̲k̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ I̲l̲l̲u̲s̲
 D̲i̲a̲g̲ N̲o̲t̲e̲s̲ ̲

W 1 CIA-A  A2A1A32   J1  MIA     A   A1A1A27   J2   58    65  RACK
                                                              A
W 2 CIA-B  A2A1A31   J1  MIA     C   A3A1A27   J2   58    65  RACK
                                                              C
W 3 CCA    A2A1A25   J1  CCBA    B   A2A4A10   J1   58    65  RACK
                                                              C
W 3                              C   A3A1A23   J1   58    65  RACK
                                                              C
W 6 SFA    A2A1A27   J1  FD      B   A2A2A5    J2   59    65  I
W 7 DCA    A2A1A28   J1  DISK    C   A3A8      J3   59    65  DISCON
W 8 DCA    A2A1A29   J1  DISK    B   A2A7      IJ3  59    65  I
W 9 DCA    A2A1A30   J1  DISK    A   A1A5      J3   59    65  DISCON
W10 DCA    A2A1A28   J2  DISK    C   A3A8      J2   59    65  DISCON
W11 DCA    A2A1A29   J2  DISK    B   A2A7      IJ2  59    65  I
W12 DCA    A2A1A30   J2  DISK    A   A1A5      J2   59    65  DISCON
W23 LIA    A2A1A23   J3  BP8     C   A3A5A24   J2   60    65  DISCON
W24 LIA    A2A1A23   J1  BP8     C   A3A5A24   J1   60    65  DISCON
W25 LIA    A2A1A22   J1  BP8     C   A3A5A25   J2   60    65  DISCON
W26 LIA    A2A1A21   J1  BP8     C   A3A5A25   J1   60    65  DISCON
W97 TSP    A2A1A26   J1  THERM   B   A2A11     *    62    68  DISCON
W98 TSP    A2A1A26   J2  THERM   B   A2A10     *    62    68  DISCON


           *  part of unit



T̲a̲b̲l̲e̲ ̲5̲.̲6̲.̲6̲





W̲A̲T̲C̲H̲D̲O̲G̲ ̲C̲R̲A̲T̲E̲ ̲R̲A̲C̲K̲ ̲B̲  

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ M̲o̲d̲u̲l̲e̲ R̲a̲c̲k̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ I̲l̲l̲u̲s̲
 D̲i̲a̲g̲ N̲o̲t̲e̲s̲ ̲

W 3 CCBA   A2A4A10   J1  CCA     B   A2A1A25   J1   58    65  RACK
                                                              C
                         CCA     A   A1A1A23   J1   58    65  RACK
                                                              C
W13 WCA    A2A4A11   J1  MIA     A   A1A1A27   J1   60    65  RACK
                                                              A
W14 WCA    A2A4A11   J2  MIA     C   A3A1A27   J1   60    65  RACK
                                                              C
W27 WCA    A2A4A11   J4  BP8     C   A3A5A25   J3   60    65  DISCON
W28 WCA    A2A4A11   J3  BP8     C   A3A5A25   J4   60    65  DISCON



T̲a̲b̲l̲e̲ ̲5̲.̲6̲.̲7̲





P̲R̲O̲C̲E̲S̲S̲O̲R̲ ̲C̲R̲A̲T̲E̲ ̲A̲S̲S̲Y̲ ̲#̲ ̲2̲ ̲R̲A̲C̲K̲ ̲C̲

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ M̲o̲d̲u̲l̲e̲ R̲a̲c̲k̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ I̲l̲l̲u̲s̲
 D̲i̲a̲g̲ N̲o̲t̲e̲s̲ ̲

W 2 MIA    A3A1A27   J2  CIA-B   B   A2A1A31   J1  58     65  DISCON
W 3 CCA    A3A1A23   J1  CCB     C   A3A16     J1  58     65  DISCON
W 3                      CCA     B   A3A1A23   J1  58     65  CON
W14 MIA    A3A1A27   J1  WCA     B   A2A4A11   J2  60     65  DISCON
W15 TIA    A3A1A25   J1  X-NET   C   A3A11     J1  60     65  I
W16 TIA    A3A1A26   J1  X-NET   C   A3A12     J1  60     65  I
W99 TSP    A3A1A24   J1  THERM   C   A3A14     *   62     68  DISCON
W100       TSP       A3A1A24     J2  THERM     C   A3A13  *
                                                              62       68 DISCON


           *  part of unit



T̲a̲b̲l̲e̲ ̲5̲.̲6̲.̲8̲





X̲-̲N̲E̲T̲ ̲O̲U̲T̲L̲E̲T̲S̲ ̲ ̲R̲A̲C̲K̲ ̲C̲ 

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ M̲o̲d̲u̲l̲e̲ R̲a̲c̲k̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ I̲l̲l̲u̲s̲
 D̲i̲a̲g̲  N̲o̲t̲e̲s̲ ̲

W17 X-NET  1A3A11    1-2 X-NET   A   1A1A8     1-2 60    34/65 RACK
                                                               A
W18 X-NET  1A3A11    4-5 X-NET   A   1A1A8     4-5 60    34/65 RACK
                                                               A
W19 X-NET  1A3A12    1-2 X-NET   A   1A1A9     1-2 60    34/65 RACK
                                                               A
W20 X-NET  1A3A12    4-5 X-NET   A   1A1A9     4-5 60    34/65 RACK
                                                               A
W905       X-NET     1A3A11      1-2 X-NET     D   2A1A13      1-2     60 34/65 RACK
                                                                                D
W906       X-NET     1A3A11      4-5 X-NET     D   2A1A13      4-5     60 34/65 RACK
                                                                                D
W907       X-NET     1A3A12      1-2 X-NET     D   2A1A14      1-2     60 34/65 RACK
                                                                                D
W908       X-NET     1A3A12      4-5 X-NET     D   2A1A14      4-5     60 34/65 RACK
                                                                                D

W904       CCB       1A3A16      J1  CCB       D   2A1A20      J1      60 
                                                                          
                                                                           RACK
                                                                           D




T̲a̲b̲l̲e̲ ̲5̲.̲6̲.̲9̲





A̲D̲A̲P̲T̲E̲R̲ ̲C̲R̲A̲T̲E̲ ̲A̲S̲S̲Y̲ ̲R̲A̲C̲K̲ ̲C̲ 

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ M̲o̲d̲u̲l̲e̲ R̲a̲c̲k̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ I̲l̲l̲u̲s̲
 D̲i̲a̲g̲ N̲o̲t̲e̲s̲ ̲

W23 BP8    A3A5A24   J2  LIA     B   A2A1A23   J3    60   
                                                          65  RACK
                                                              B
W24 BP8    A3A5A24   J1  LIA     B   A2A1A23   J1    60   
                                                          65  RACK
                                                              B
W25 BP8    A3A5A25   J2  LIA     B   A2A1A21   J1    60   
                                                          65  RACK
                                                              B
W26 BP8    A3A5A25   J1  LIA     B   A2A1A22   J1    60   
                                                          65  RACK
                                                              B
W27 BP8    A3A5A25   J3  WCA     B   A2A4A11   J4    60   
                                                          65  RACK
                                                              B
W28 BP8    A3A5A25   J4  WCA     B   A2A4A11   J3    60   
                                                          65  RACK
                                                              B
W909       L/L-AD    A3A5A9      J1  FILTER    F    A3A17 J31 375      370 RACK
                                                                           F
W910       L/L-AD    A3A5A10     J1  FILTER    F    A3A17 J30 375      370 RACK
                                                                           F
W911       L/L-AD    A3A5A14     J1  FILTER    F    A3A17 J29 375      370 RACK
                                                                           F
W912       L/L-AD    A3A5A15     J1  FILTER    F    A3A17 J28 375      370 RACK
                                                                           F
W913       L/L-AD    A3A5A16     J1  FILTER    F    A3A17 J26 375      370 RACK
                                                                           F
W914       L/L-AD    A3A5A17     J1  FILTER    F    A3A17 J27 375      370 RACK
                                                                           F





T̲a̲b̲l̲e̲ ̲5̲.̲6̲.̲1̲0̲





D̲I̲S̲K̲ ̲D̲R̲I̲V̲E̲ ̲R̲A̲C̲K̲ ̲C̲


                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ M̲o̲d̲u̲l̲e̲ R̲a̲c̲k̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ I̲l̲l̲u̲s̲
 D̲i̲a̲g̲ N̲o̲t̲e̲s̲ ̲

W7  DISK   A3A8      J3  DCA     B   A2A1A28   J1   59    65  RACK
                                                              B
W10 DISK   A3A8      J2  DCA     B   A2A1A28   J2   59    65  RACK
                                                              B





T̲a̲b̲l̲e̲ ̲5̲.̲6̲.̲1̲1̲





R̲A̲C̲K̲ ̲D̲ 

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ M̲o̲d̲u̲l̲e̲ R̲a̲c̲k̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ I̲l̲l̲u̲s̲
 D̲i̲a̲g̲ N̲o̲t̲e̲s̲ ̲ ̲

W101        BSM-P    A1A3A25     J2  BSM-P     D    A1A1A25   J2       170 190
W101        BSM-P    A1A1A25     J2  BSM-P     E    A2A9A25   J2       170 190 RACK
                                                                               F
W101        BSM-P    A1A7A25     J2  BSM-P     D    A1A9A25   J2       170 190 RACK
                                                                               F
W101        BSM-P    A1A3A25     J2  BSM-P     D    A1A7A25   J2       170 190 RACK
                                                                               F
W101        BSM-P    A1A9A25     J2  CCB       D    A1A20     J1       170 190 RACK
                                                                               F
W104        BSM-X    A1A1A3      J1  TDX CNT   D    A1A1A2    J1       170 190 I
W105        BSM-X    A1A9A3      J1  TDX CNT   D    A1A9A2    J1       170 190 I
W106        TDX CNT  A1A1A2      J2  X-NET     D    A1A15     J1       171 190 I
W107        TDX CNT  A1A9A2      J2  X-NET     D    A1A25     J1       171 190 I
W108        BSM-P    A1A1A25     J3  X-NET     D    A1A13     J1       171 190 CON
W109        BSM-P    A1A1A25     J1  X-NET     D    A1A14     J1       171 190 CON
W110        BSM-P    A1a3A25     J3  X-NET     D    A1A16     J1       171 190 CON
W111        BSM-P    A1A3A25     J1  X-NET     D    A1A17     J1       171 190
                                                                            CON
W112        BSM-P    A1A7A25     J3  X-NET     D    A1A21     J1       171 190 CON
W113        BSM-P    A1A7A25     J1  X-NET     D    A1A22     J1       171 190 CON
W114        BSM-P    A1A9A25     J3  X-NET     D    A1A23     J1       171 190 CON
W115        BSM-P    A1A9A25     J1  X-NET     D    A1A24     J1       171 190 CON
W141        X-NET    A1A14       4-5 X-NET     D    A1A17     4-5      171 190 CON
W142        X-NET    A1A14       1-2 X-NET     D    A1A17     1-2      171 190 CON
W143        X-NET    A1A13       4-5 X-NET     D    A1A15     1-2      171 190 CON
W144        X-NET    A1A13       1-2 X-NET     D    A1A15     4-5      171 190 CON
W145        X-NET    A1A17       4-5 X-NET     D    A1A22     4-5      171 190 CON
W146        X-NET    A1A17       1-2 X-NET     D    A1A22     1-2      171 190 CON
W147        X-NET    A1A15       4-5 X-NET     D    A1A16     1-2      171 190 CON
W148        X-NET    A1A15       1-2 X-NET     D    A1A16     4-5      171 190 CON
W149        X-NET    A1A22       4-5 X-NET     D    A1A24     4-5      171 190 CON
W150        X-NET    A1A22       1-2 X-NET     D    A1A24     1-2      171 190 CON
W151        X-NET    A1A16       4-5 X-NET     D    A1A21     4-5      171 190 CON
W152        X-NET    A1A16       1-2 X-NET     D    A1A21     1-2      171 190 CON
W153        X-NET    A1A24       4-5 X-NET     D    A1A25     1-2      171 190 CON
W154        X-NET    A1A24       1-2 X-NET     D    A1A25     4-5      171 190 CON
W155        X-NET    A1A21       4-5 X-NET     D    A1A23     4-5      171 190 CON
W156        X-NET    A1A21       1-2 X-NET     D    A1A23     1-2      171 190 CON
W157        X-NET    A1A25       1-2 X-NET     E    A2A14       4-5   171
                                                                      144/190 RACK
                                                                              E
W158        X-NET    A1A25       4-5 X-NET     E    A2A14       1-2   171
                                                                      144/190 RACK
                                                                              E


T̲a̲b̲l̲e̲ ̲5̲.̲6̲.̲1̲1̲





R̲A̲C̲K̲ ̲D̲    

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ M̲o̲d̲u̲l̲e̲ R̲a̲c̲k̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ I̲l̲l̲u̲s̲
 D̲i̲a̲g̲ N̲o̲t̲e̲s̲ ̲ ̲

W159       X-NET    A1A23        4-5 X-NET    E    2A2A13      4-5     171
                                                                       144/190 RACK
                                                                               E
W160       X-NET    A1A23        1-2 X-NET    E    2A2A13      1-2     171
                                                                       144/190 RACK
                                                                               E
W904       CCB      A1A20        J1  CCB      C    1A3A16      J1      171
                                                                       190 CON
W905       X-NET    A1A13        1-2 X-NET    C    1A3A11      1-2     171
                                                                       143/190 CON
W906       X-NET    A1A13        4-5 X-NET    C    1A3A11      4-5     171
                                                                       143/190 CON
W907       X-NET    A1A14        1-2 X-NET    C    1A3A12      1-2     171
                                                                       143/190 CON
W908       X-NET    A1A14        4-5 X-NET    C    1A3A12      4-5     171
                                                                       143/190 CON




W293       TSP      A1A3A22      J1  THERMO   D    A1A18      *        172 225  I
W294       TSP      A1A9A22      J1  THERMO   D    A1A26      *        172 225  I


           * part of unit…86…1    …02…      …02…        …02…    …02…      
           …02…   …02…        …02…    …02…    …02…     …02……02…       
T̲a̲b̲l̲e̲ ̲5̲.̲6̲.̲1̲2̲





R̲A̲C̲K̲ ̲E̲   

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ M̲o̲d̲u̲l̲e̲ R̲a̲c̲k̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ I̲l̲l̲u̲s̲
 D̲i̲a̲g̲ N̲o̲t̲e̲s̲ ̲ ̲

W101       BSM-P     A2A9A25     J2  BSM-P     D    A1A1A25   J2       170 190 DISCON
W101       BSM-P     A2A7A25     J2  BSM-P     E    A2A9A25   J2       170 190 RACK
                                                                               F
W101       BSM-P     A2A7A25     J2  BSM-P     E    A2A3A25   J2       171 190 RACK
                                                                               F
W101       BSM-P     A2A3A25     J2  BSM-P     E    A2A1A25   J2       171 190 RACK
                                                                               F
W101       BSM-P     A2A1A25     J2  BSM-P     F    A3A3A25   J2       171 190 RACK
                                                                               F
W116       BSM-P     A2A1A25     J3  X-NET     E    A2A13     J1       171 190 CON
W117       BSM-P     A2A1A25     J1  X-NET     E    A2A14     J1       171 190 CON
W118       BSM-P     A2A3A25     J3  X-NET     E    A2A15     J1       171 190 CON
W119       BSM-P     A2A3A25     J1  X-NET     E    A2A16     J1       171 190 CON
W120       BSM-P     A2A7A25     J3  X-NET     E    A2A19     J1       171 190 CON
W121       BSM-P     A2A7A25     J1  X-NET     E    A2A20     J1       171 190 CON
W122       BSM-P     A2A9A25     J3  X-NET     E    A2A21     J1       171 190 CON
W123       BSM-P     A2A9A25     J1  X-NET     E    A2A22     J1       171 190 CON
W157       X-NET     A2A14       4-5 X-NET     D    A1A25     4-5      171 190 RACK
                                                                               E
W158       X-NET     A2A14       1-2 X-NET     D    A1A25     1-2      171 190 RACK
                                                                               E
W159       X-NET     A2A13       1-2 X-NET     D    A1A23     1-2      171 190 RACK
                                                                               E
W160       X-NET     A2A13       4-5 X-NET     D    A1A23     4-5      171 190 RACK
                                                                               E
W161       X-NET     A2A14       4-5 X-NET     E    A2A16     4-5      171 190 CON
W162       X-NET     A2A14       1-2 X-NET     E    A2A16     1-2      171 190 CON
W163       X-NET     A2A13       4-5 X-NET     E    A2A15     4-5      171 190 CON
W164       X-NET     A2A13       1-2 X-NET     E    A2A15     1-2      171 190 CON
W165       X-NET     A2A16       4-5 X-NET     E    A2A20     4-5      171 190 CON
W166       X-NET     A2A16       1-2 X-NET     E    A2A20     1-2      171 190 CON
W167       X-NET     A2A15       4-5 X-NET     E    A2A19     4-5      171 190 CON
W168       X-NET     A2A15       1-2 X-NET     E    A2A19     1-2      171 190 CON
W169       X-NET     A2A20       4-5 X-NET     E    A2A22     4-5      171 190 CON
W170       X-NET     A2A20       1-2 X-NET     E    A2A22     1-2      171 190 CON
W171       X-NET     A2A19       4-5 X-NET     E    A2A21     4-5      171 190 CON
W172       X-NET     A2A19       1-2 X-NET     E    A2A21     1-2      171 190 CON
W173       X-NET     A2A22       1-2 X-NET     F    A3A11     1-2      171
                                                                       144/190
                                                                       RACK
                                                                       F
W174       X-NET     A2A22       4-5 X-NET     F    A3A11     4-5      171
                                                                       144/190
                                                                       RACK
                                                                       F
W175       X-NET     A2A21       1-2 X-NET     F    A3A10     1-2      171
                                                                       144/190
                                                                       RACK
                                                                       F
W176       X-NET     A2A21       4-5 X-NET     F    A3A10     4-5      171
                                                                       144/190
                                                                       RACK
                                                                       F
W295       TSP       A2A3A22     J1  THERMO    E    A2A17     *
                                                              
                                                              
                                                                       172 225 I
W296       TSP       A2A9A22     J1  THERMO    E    A2A23     *
                                                              
                                                                       172 225
                                                                            I


           * part of unit



T̲a̲b̲l̲e̲ ̲5̲.̲6̲.̲1̲3̲





T̲D̲X̲ ̲C̲R̲A̲T̲E̲ ̲A̲S̲S̲Y̲ ̲6̲ ̲R̲A̲C̲K̲ ̲E̲

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ M̲o̲d̲u̲l̲e̲ R̲a̲c̲k̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ I̲l̲l̲u̲s̲
 D̲i̲a̲g̲ N̲o̲t̲e̲s̲ ̲ ̲

W585       L/L AD    A2A7A7      J1  IDF       F    A3A17     J46      172 207 RACK
                                                                               F
W586       L/L AD    A2A7A7      J2  IDF       F    A3A17     J47      172 207 RACK
                                                                               F
W587       L/L AD    A2A7A7      J3  IDF       F    A3A17     J48      172 207 RACK
                                                                               F
W588       L/L AD    A2A7A7      J4  IDF       F    A3A17     J49      172 207 RACK
                                                                               F




T̲a̲b̲l̲e̲ ̲5̲.̲6̲.̲1̲4̲





T̲D̲X̲ ̲C̲R̲A̲T̲E̲ ̲A̲S̲S̲Y̲ ̲7̲ ̲R̲A̲C̲K̲ ̲E̲ 

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ M̲o̲d̲u̲l̲e̲ R̲a̲c̲k̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ I̲l̲l̲u̲s̲
 D̲i̲a̲g̲ N̲o̲t̲e̲s̲ ̲

W201        L/L AD   A2A3A7      J1  IDF       F    A3A17     J1       172 207 RACK
                                                                               F
W202        L/L AD   A2A3A7      J2  IDF       F    A3A17     J2       172 207 RACK
                                                                               F
W203        L/L AD   A2A3A7      J3  IDF       F    A3A17     J3       172 207 RACK
                                                                               F
W204        L/L AD   A2A3A7      J4  IDF       F    A3A17     J4       172 207 RACK
                                                                               F
W205        L/L AD   A2A3A14     J1  IDF       F    A3A17     J5       172 207 RACK
                                                                               F
W206        L/L AD   A2A3A14     J2  IDF       F    A3A17     J6       172 207 RACK
                                                                               F
W207        L/L AD   A2A3A14     J4  IDF       F    A3A17     J7       172 207 RACK
                                                                               F
W208        L/L AD   A2A3A14     J3  IDF       F    A3A17     J8       172 207 RACK
                                                                               F



T̲a̲b̲l̲e̲ ̲5̲.̲6̲.̲1̲5̲





T̲D̲X̲ ̲C̲R̲A̲T̲E̲ ̲A̲S̲S̲Y̲ ̲8̲ ̲R̲A̲C̲K̲ ̲E̲ 

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ M̲o̲d̲u̲l̲e̲ R̲a̲c̲k̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ I̲l̲l̲u̲s̲
 D̲i̲a̲g̲ N̲o̲t̲e̲s̲ ̲

W209        L/L AD   A2A1A7      J1  IDF       F    A3A17     J
                                                              9        172 207 RACK
                                                                               F
W210        L/L AD   A2A1A7      J2  IDF       F    A3A17     J10      172 207 RACK
                                                                               F
W211        L/L AD   A2A1A7      J3  IDF       F    A3A17     J11      172 207 RACK
                                                                               F
W212        L/L AD   A2A1A7      J4  IDF       F    A3A17     J12      172 207 RACK
                                                                               F
W213        L/L AD   A2A1A14     J1  IDF       F    A3A17     J13      172 207 RACK
                                                                               F
W214        L/L AD   A2A1A14     J2  IDF       F    A3A17     J14      172 207 RACK
                                                                               F
W215        L/L AD   A2A1A14     J3  IDF       F    A3A17     J15      172 207 RACK
                                                                               F
W216        L/L AD   A2A1A14     J4  IDF       F    A3A17     J16      172 207 RACK
                                                                               F


T̲a̲b̲l̲e̲ ̲5̲.̲6̲.̲1̲6̲





R̲A̲C̲K̲ ̲F̲

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ M̲o̲d̲u̲l̲e̲ R̲a̲c̲k̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ I̲l̲l̲u̲s̲
 D̲i̲a̲g̲ N̲o̲t̲e̲s̲ ̲

W101        BSM-P    A3A1A25     J2  CCB-P     F    A3A16     J1       170 190 CON
W101        BSM-P    A3A3A25     J2  BSM-P     E    A2A1A25   J2       170 190 CON
W101        BSM-P    A3A1A25     J2  BSM-P     F    A3A3A25   J2       170 190 CON
W102        BSP-P    A3A18A25    J3  CCB-P     F    A3A16     J1       170 190 CON
W124        BSM-P    A3A1A25     J3  X-NET     F    A3A10
                                                         J1   171      190 CON
W125        BSM-P    A3A1A25     J1  X-NET     F    A3A11
                                                         J1   171      190 CON
W126        BSM-P    A3A3A25     J3  X-NET     F    A3A12
                                                         J1   171      190 CON
W127        BSM-P    A3A3A25     J1  X-NET     F    A3A13
                                                         J1   171      190 CON
W128        BSM-P    A3A18A11    J1  X-NET     F    A3A23     J1       171 190 CON
W129        BSM-P    A3A18A11    J3  X-NET     F    A3A22     J1       171 190 CON
W173        X-NET    A3A11       1-2 X-NET     E    A2A22
                                                         1-2  171      190 RACK
                                                                           E
W174        X-NET    A3A11       4-5 X-NET     E    A2A22
                                                         4-5  171      190 RACK
                                                                           E
W175        X-NET    A3A10       1-2 X-NET     E    A2A21     1-2      171 190 RACK
                                                                               E
W176        X-NET    A3A10       4-5 X-NET     E    A2A21
                                                         4-5  171      190 RACK
                                                                           E
W177        X-NET    A3A11       1-2 X-NET     F    A3A13
                                                         1-2  171      190 CON
                                                                           
                                                                           
                                                                           
W178        X-NET    A3A11       4-5 X-NET     F    A3A13
                                                         4-5  171      190 CON
                                                                           
                                                                           
                                                                           
W179        X-NET    A3A10       1-2 X-NET     F    A3A12
                                                         1-2  171      190 CON
                                                                           
                                                                           
                                                                           
W180        X-NET    A3A10       4-5 X-NET     F    A3A12
                                                         4-5  171      190 CON
                                                                           
                                                                           
                                                                           
W181        X-NET    A3A23       1-2 X-NET     F    A3A13     1-2      171 190 CON
W182        X-NET    A3A23       4-5 X-NET     F    A3A13     4-5      171 190 CON
W183        X-NET    A3A22       1-2 X-NET     F    A3A12     1-2      171 190 CON
W184        X-NET    A3A22       4-5 X-NET     F    A3A12     4-5      171 190 CON
W297        TSP      A3A3A22     J1  THERMO    F    A3A14     *        172 225 I


    * Part of Unit


T̲a̲b̲l̲e̲ ̲5̲.̲6̲.̲1̲7̲





F̲I̲L̲T̲E̲R̲ ̲B̲O̲X̲ ̲R̲A̲C̲K̲ ̲F̲ 

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ M̲o̲d̲u̲l̲e̲ R̲a̲c̲k̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ I̲l̲l̲u̲s̲
 D̲i̲a̲g̲ N̲o̲t̲e̲s̲ ̲

W201        IDF      2A3A17      J1  L/L AD    E    A2A3A7    J1       172 207 CON
W202        IDF      2A3A17      J2  L/L AD    E    A2A3A7
                                                         J2   172      207 CON
W203        IDF      2A3A17      J3  L/L AD    E    A2A3A7
                                                         J3   172      207 CON
W204        IDF      2A3A17      J4  L/L AD    E    A2A3A7
                                                         J4   172      207 CON
W205        IDF      2A3A17      J5  L/L AD    E    A2A3A14   J1       172 207 CON
W206        IDF      2A3A17      J6  L/L AD    E    A2A3A14   J2       172 207 CON
W207        IDF      2A3A17      J7  L/L AD    E    A2A3A14   J3       172 207 CON
W208        IDF      2A3A17      J8  L/L AD    E    A2A3A14   J4
                                                                       172 207 CON
                                                                               
                                                                               
                                                                               
W209        IDF      2A3A17      J9  L/L AD    E    A2A1A7    J1
                                                                       172 207 RACK
                                                                               E
W210        IDF      2A3A17      J10 L/L AD    E    A2A1A7
                                                         J2
                                                              172      207 RACK
                                                                           E
W211        IDF      2A3A17      J11 L/L AD    E    A2A1A7
                                                         J3
                                                              172      207 CON
                                                                           
                                                                           
                                                                           
W212        IDF      2A3A17      J12 L/L AD    E    A2A17
                                                         J4
                                                              172      207 CON
                                                                           
                                                                           
                                                                           
W213        IDF      2A3A17      J13 L/L AD    E    A2A1A14   J1
                                                                       172 207 CON
                                                                               
                                                                               
                                                                               
W214        IDF      2A3A17      J14 L/L AD    E    A2A1A14   J2
                                                                       172 207 CON
                                                                               
                                                                               
                                                                               
W215        IDF      2A3A17      J15 L/L AD    E    A2A1A14   J3
                                                              
                                                                       172 207 CON
W215        IDF      2A3A17      J15 L/L AD    E    A2A1A14   J3
                                                              
                                                                       172 207 CON
W216        IDF      2A3A17      J16 L/L AD    E    A2A1A14   J4
                                                              
                                                                       172 207 CON
W217        IDF      2A3A17      J17 L/L AD    F    A3A3A7
                                                         J1
                                                         
                                                              172      207 CON
W218        IDF      2A3A17      J18 L/L AD    F    A3A3A7
                                                         J2
                                                         
                                                              172      207 CON
W219        IDF      2A3A17      J19 L/L AD    F    A3A3A7
                                                         J3
                                                         
                                                              172      207 CON
W220        IDF      2A3A17      J20 L/L AD    F    A3A3A7
                                                         J4
                                                         
                                                              172      207 CON
W221        IDF      2A3A17      J21 L/L AD    F    A3A3A14   J1
                                                              
                                                                       172 207 CON
W222        IDF      2A3A17      J22 L/L AD    F    A3A3A14   J2
                                                              
                                                                       172 207 CON
W223        IDF      2A3A17      J23 L/L AD    F    A3A3A14   J3
                                                              
                                                                       172 207 CON
W224        IDF      2A3A17      J24 L/L AD    F    A3A3A14   J4
                                                              
                                                                       172 207 CON
W225        IDF      2A3A17      J25 L/L AD    F    A3A1A14   J1
                                                              
                                                                       172 207 CON
W232        IDF      2A3A17      J32 L/L AD    F    A3A1A10   J1
                                                              
                                                                       172 207 CON
W585        IDF      2A3A17      J46 L/L AD    E    A2A7A7    J1       172 207 CON
W586        IDF      2A3A17      J47 L/L AD    E    A2A7A7    J2       172 207 CON
W587        IDF      2A3A17      J48 L/L AD    E    A2A7A7    J3       172 207 CON
W588        IDF      2A3A17      J49 L/L AD    E    A2A7A7    J4       172 207 CON
W909        IDF      2A3A17      J31 L/L AD    C    A3A5A9
                                                         J1
                                                         
                                                              375      370 CON
W910        IDF      2A3A17      J30 L/L AD    C    A3A5A10   J1
                                                              
                                                                       375 370 RACK
                                                                               F




T̲a̲b̲l̲e̲ ̲5̲.̲6̲.̲1̲8̲





T̲D̲X̲ ̲C̲R̲A̲T̲E̲ ̲A̲S̲S̲Y̲ ̲5̲ ̲R̲A̲C̲K̲ ̲E̲ 

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ M̲o̲d̲u̲l̲e̲ R̲a̲c̲k̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ I̲l̲l̲u̲s̲
 D̲i̲a̲g̲ N̲o̲t̲e̲s̲ ̲


W911        IDF      2A3A17      J29 L/L AD    C    A3A5A14   J1       375 370 RACK
                                                                               F
W912        IDF      2A3A17      J28 L/L AD    C    A3A5A15   J1       375 370 RACK
                                                                               F
W913        IDF      2A3A17      J27 L/L AD    C    A3A5A16   J1       375 370 RACK
                                                                               F
W914        IDF      2A3A17      J26 L/L AD    C    A3A5A17   J1       375 370 RACK
                                                                               F



    OBSERVE THAT THE YELLOW LABELED END OF THE 
    CABLES BETWEEN IDF AND THE L/L ADP. MUST BE
    CONNECTED AT THE L/L ADP.


T̲a̲b̲l̲e̲ ̲5̲.̲6̲.̲1̲9̲





T̲D̲X̲ ̲C̲R̲A̲T̲E̲ ̲A̲S̲S̲Y̲ ̲9̲ ̲R̲A̲C̲K̲ ̲F̲

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ M̲o̲d̲u̲l̲e̲ R̲a̲c̲k̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ I̲l̲l̲u̲s̲
 D̲i̲a̲g̲  N̲o̲t̲e̲s̲ ̲

W217       L/L AD    A3A3A7      J1  IDF       F    A3A17
                                                         J17   172     207 RACK
                                                                           F
W218       L/L AD    A3A3A7      J2  IDF       F    A3A17
                                                         J18   172     207 RACK
                                                                           F
W219       L/L AD    A3A3A7      J3  IDF       F    A3A17
                                                         J19   172     207 RACK
                                                                           F
W220       L/L AD    A3A3A7      J4  IDF       F    A3A17
                                                         J20   172     207 RACK
                                                                           F
W221       L/L AD    A3A3A14     J1  IDF       F    A3A17
                                                         J21   172     207 RACK
                                                                           F
W222       L/L AD    A3A3A14     J2  IDF       F    A3A17
                                                         J22   172     207 RACK
                                                                           F
W223       L/L AD    A3A3A14     J3  IDF       F    A3A17
                                                         J23   172     207 RACK
                                                                           F
W224       L/L AD    A3A3A14     J4  IDF       F    A3A17
                                                         J24   172     207 RACK
                                                                           F


T̲a̲b̲l̲e̲ ̲5̲.̲6̲.̲2̲0̲





T̲D̲X̲ ̲C̲R̲A̲T̲E̲ ̲A̲S̲S̲Y̲ ̲1̲0̲ ̲R̲A̲C̲K̲ ̲F̲

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ M̲o̲d̲u̲l̲e̲ R̲a̲c̲k̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ I̲l̲l̲u̲s̲
 D̲i̲a̲g̲ N̲o̲t̲e̲s̲ ̲

W225       L/L AD    A3A1A14     J1  IDF       F    A3A17     J25      172 207 RACK
                                                                               F
W232       L/L AD    A3A1A10     J1  IDF       F    A3A17     J32      172 207 RACK
                                                                               F


5.7      T̲E̲R̲M̲I̲N̲A̲T̲I̲O̲N̲ ̲O̲F̲ ̲E̲X̲T̲E̲R̲N̲A̲L̲ ̲S̲I̲G̲N̲A̲L̲ ̲C̲A̲B̲L̲E̲S̲



         a)  All external opto fibre cables located on the front
             of the TDX- and adapter crates are cut, withdrawn
             to the rear of the rack and terminated with special
             opto connectors. For details of opto termination
             procedures refer to para 1.3 Doc. No. 4.

         b)  All external metallic cables located in the filter
             box (ref. 4.4) can now be terminated and connected
             in the filter box.

             For distribution of the metallic cables inside
             the filter box see ATBB drawing 125.

         c)  When terminated, all opto fibre cables are distributed
             through the internal cables channels of the racks
             and out through the cable channel assy below the
             TDX and adapter crates (see ATBB drawings 117/125)

             C̲A̲U̲T̲I̲O̲N̲

             Be specially careful when installing the opto fibre
             cables. Min. bending radius is 13mm.

         d)  The opto fibre cables are connected to the opto
             T/R adapters from the front of the TDX crates according
             to tables 5.7.2 through 5.7.6 (ref. ATBB drawing
             125/102).

 …86…1         …02…   …02…   …02…   …02…           …02…                            
   
T̲a̲b̲l̲e̲ ̲5̲.̲7̲.̲2̲





A̲D̲A̲P̲T̲E̲R̲ ̲C̲R̲A̲T̲E̲ ̲A̲S̲S̲Y̲ ̲R̲A̲C̲K̲ ̲C̲ 

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲    L̲o̲c̲a̲t̲i̲o̲n̲    T̲e̲r̲m̲i̲n̲a̲l̲    L̲o̲c̲a̲t̲i̲o̲n̲    N̲o̲t̲e̲s̲
 ̲ ̲ ̲ ̲ ̲ ̲          

W811          OPTO T/R     1A3A5A7    VDU      CAMPS AREA
                                                MAINT.
                                               POS.
W812          OPTO T/R     1A3A5A8    MSP      CAMPS AREA
                                                MAINT.
                                               POS.



T̲a̲b̲l̲e̲ ̲5̲.̲7̲.̲3̲





T̲D̲X̲ ̲C̲R̲A̲T̲E̲ ̲A̲S̲S̲Y̲ ̲#̲ ̲1̲ ̲R̲A̲C̲K̲ ̲D̲ 

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲    L̲o̲c̲a̲t̲i̲o̲n̲    T̲e̲r̲m̲i̲n̲a̲l̲    L̲o̲c̲a̲t̲i̲o̲n̲    N̲o̲t̲e̲s̲
 ̲              

W824          OPTO T/R     2A1A9A7    VDU      T 1052                   USER
                                                                        P
W821          OPTO T/R     2A1A9A8    VDU      I 144/145
                                                  USER
                                                  P
W818          OPTO T/R     2A1A9A9    VDU      CAMPS ROOM              SUP.
                                                                       P
W815          OPTO T/R     2A1A9A10   VDU      CAMPS ROOM              SUP.
                                                                       P
W836          OPTO T/R     2A1A9A14   VDU      T 1082                   USER
                                                                        P
W833          OPTO T/R     2A1A9A15   VDU      M201   
                                                  USER
                                                  P
W830          OPTO T/R     2A1A9A16   VDU      M228A  
                                                  USER
                                                  P
W827          OPTO T/R     2A1A9A17   VDU      M229   
                                                  USER
                                                  P





T̲a̲b̲l̲e̲ ̲5̲.̲7̲.̲4̲





T̲D̲X̲ ̲C̲R̲A̲T̲E̲ ̲A̲S̲S̲Y̲ ̲#̲ ̲2̲ ̲R̲A̲C̲K̲ ̲D̲ 

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲    L̲o̲c̲a̲t̲i̲o̲n̲    T̲e̲r̲m̲i̲n̲a̲l̲    L̲o̲c̲a̲t̲i̲o̲n̲    N̲o̲t̲e̲s̲
 ̲            

W825          OPTO T/R     2A1A7A7    VDU      M 216  
                                                  USER
                                                  P
W822          OPTO T/R     2A1A7A8    VDU      I 123           USER
                                                               P
W819          OPTO T/R     2A1A7A9    VDU      CAMPS ROOM      USER
                                                               P
W816          OPTO T/R     2A1A7A10   VDU      CAMPS ROOM      SUP.
                                                               P
W837          OPTO T/R     2A1A7A14   VDU      I 323  
                                                  USER
                                                  P
W834          OPTO T/R     2A1A7A15   VDU      T 4061 
                                                  USER
                                                  P
W831          OPTO T/R     2A1A7A16   VDU      M 202  
                                                  USER
                                                  P
W828          OPTO T/R     2A1A7A17   VDU      I 323  
                                                  USER
                                                  P



T̲a̲b̲l̲e̲ ̲5̲.̲7̲.̲5̲





T̲D̲X̲ ̲C̲R̲A̲T̲E̲ ̲A̲S̲S̲Y̲ ̲#̲ ̲3̲ ̲R̲A̲C̲K̲ ̲D̲

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲    L̲o̲c̲a̲t̲i̲o̲n̲    T̲e̲r̲m̲i̲n̲a̲l̲    L̲o̲c̲a̲t̲i̲o̲n̲    N̲o̲t̲e̲s̲
 ̲ ̲

W826          OPTO T/R     2A1A3A7    VDU      M 216  
                                                  USER
                                                  P
W823          OPTO T/R     2A1A3A8    VDU      T 1052          USER
                                                               P
W820          OPTO T/R     2A1A3A9    VDU      I 144/145 USER
                                                         P
W817          OPTO T/R     2A1A3A10   VDU      CAMPS ROOM
                                                  SUP.
                                                  P
W838          OPTO T/R     2A1A3A14   VDU      H 207           USER
                                                               P
W835          OPTO T/R     2A1A3A15   VDU      T 4077          USER
                                                               P
W832          OPTO T/R     2A1A3A16   VDU      M 203           USER
                                                               P
W829          OPTO T/R     2A1A3A17   VDU      M 201           USER
                                                               P



T̲a̲b̲l̲e̲ ̲5̲.̲7̲.̲6̲





T̲D̲X̲ ̲C̲R̲A̲T̲E̲ ̲A̲S̲S̲Y̲ ̲#̲ ̲4̲ ̲R̲A̲C̲K̲ ̲D̲

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲    L̲o̲c̲a̲t̲i̲o̲n̲    T̲e̲r̲m̲i̲n̲a̲l̲    L̲o̲c̲a̲t̲i̲o̲n̲    N̲o̲t̲e̲s̲
 ̲ ̲

W839          OPTO T/R     2A1A1A7    VDU      M 218  
                                                  USER
                                                  P
W840          OPTO T/R     2A1A1A8    VDU      OA 219          USER
                                                               P
W841          OPTO T/R     2A1A1A9    VDU      C 215/216 USER
                                                         P
W842          OPTO T/R     2A1A1A10   VDU      D 133           USER
                                                               P
W843          OPTO T/R     2A1A1A14   VDU      B 349           USER
                                                               P
W844          OPTO T/R     2A1A1A15   VDU      C 146           USER
                                                               P
W845          OPTO T/R     2A1A1A16   VDU      D 237           USER
                                                               P
W846          OPTO T/R     2A1A1A17   VDU      X 217           USER
                                                               P


T̲a̲b̲l̲e̲ ̲5̲.̲7̲.̲7̲





T̲D̲X̲ ̲C̲R̲A̲T̲E̲ ̲A̲S̲S̲Y̲ ̲#̲ ̲5̲ ̲R̲A̲C̲K̲ ̲E̲ 

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲    L̲o̲c̲a̲t̲i̲o̲n̲    T̲e̲r̲m̲i̲n̲a̲l̲    L̲o̲c̲a̲t̲i̲o̲n̲    N̲o̲t̲e̲s̲
 ̲ ̲

W852          OPTO T/R     2A2A9A7    MSP      M 217           USER
                                                               P
W851          OPTO T/R     2A2A9A8    MSP      M 216  
                                                  USER
                                                  P
W849          OPTO T/R     2A2A9A9    MSP      I 144/145
                                                  SUP.
                                                  P
W847          OPTO T/R     2A2A9A10   MSP      CAMPS ROOM      SUP.
                                                               P
W854          OPTO T/R     2A2A9A14   MSP      I 323  
                                                  USER
                                                  P
W853          OPTO T/R     2A2A9A15   MSP      I 323  
                                                  USER
                                                  P
W850          OPTO T/R     2A2A9A16   MSP      T 1052 
                                                  SUP.
                                                  P
W848          OPTO T/R     2A2A9A17   MSP      CAMPS ROOM      SUP.
                                                               P



T̲a̲b̲l̲e̲ ̲5̲.̲7̲.̲8̲





T̲D̲X̲ ̲C̲R̲A̲T̲E̲ ̲A̲S̲S̲Y̲ ̲#̲ ̲6̲ ̲R̲A̲C̲K̲ ̲E̲ 

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲    L̲o̲c̲a̲t̲i̲o̲n̲    T̲e̲r̲m̲i̲n̲a̲l̲    L̲o̲c̲a̲t̲i̲o̲n̲    N̲o̲t̲e̲s̲
 ̲ ̲

W885          OPTO T/R     2A2A7A17   VDU      B 150           USER
                                                               P
W886          OPTO T/R     2A2A7A16   VDU      A 239/240
                                                  USER
                                                  P
W887          OPTO T/R     2A2A7A15   VDU      B1        USER
                                                         P
W889          OPTO T/R     2A2A7A14   VDU      C 308           USER
                                                               P


T̲a̲b̲l̲e̲ ̲5̲.̲7̲.̲9̲





T̲D̲X̲ ̲C̲R̲A̲T̲E̲ ̲A̲S̲S̲Y̲ ̲#̲ ̲1̲1̲ ̲R̲A̲C̲K̲ ̲F̲ 

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲    L̲o̲c̲a̲t̲i̲o̲n̲    T̲e̲r̲m̲i̲n̲a̲l̲    L̲o̲c̲a̲t̲i̲o̲n̲    N̲o̲t̲e̲s̲
 ̲ ̲

W890          OPTO T/R     2A3A18A15  VDU      B 334           USER
                                                               P
W891          OPTO T/R     2A3A18A14  VDU      B 132           USER
                                                               P
W892          OPTO T/R     2A3A18A10  VDU      G3        USER
                                                         P
W893          OPTO T/R     2A3A18A9   VDU      A 150           USER
                                                               P
W894          OPTO T/R     2A3A18A8   VDU      A 340           USER
                                                               P
W895          OPTO T/R     2A3A18A7   VDU      E 121           USER
                                                               P



5.8      C̲O̲N̲N̲E̲C̲T̲I̲O̲N̲ ̲O̲F̲ ̲I̲N̲T̲E̲R̲N̲A̲L̲ ̲P̲O̲W̲E̲R̲ ̲C̲A̲B̲L̲E̲S̲

         a)  Tables 5.8.2 through 5.8.7 list all internal power
             cables in the processor racks, the line termination
             racks, and in the frequency stabilizer rack.

         b)  Use the tables as an installation step by step
             procedure and as a checkout of cables already installed
             (see ATBB drawings 117, 118, and 120).

         c)  All power plugs connected to fans and crates must
             be secured by the connector spring mounted on the
             male connector.

         W̲A̲R̲N̲I̲N̲G̲:

         I̲                    INTERNAL CABLE
                              Both ends of the cable must be
                              connected/checked in this step
                              (ref. left a̲n̲d̲ right hand side
                              of the table).

         C̲O̲N̲                  Cable has not been disconnected.
                              Check for correct W-number.

         D̲I̲S̲C̲O̲N̲               Cable has been disconnected. The
                              cable is not removed from the
                              rack cable tray. The connector
                              is to be found near by the termination
                              point.

         R̲A̲C̲K̲ ̲(̲A̲,̲ ̲B̲,̲ ̲C̲,̲ ̲E̲T̲C̲)̲  Cable has been withdrawn during
                              transportation and is now found
                              in e.g. rack A.




T̲a̲b̲l̲e̲ ̲5̲.̲8̲.̲2̲





R̲A̲C̲K̲ ̲A̲  

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ M̲o̲d̲u̲l̲e̲ R̲a̲c̲k̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ I̲l̲l̲u̲s̲
 D̲i̲a̲g̲ N̲o̲t̲e̲s̲ ̲ ̲

W40 PROC     A1A1    J1  PDP     A    A1A12    J1   61    67  CONN/I
W41 PROC     A1A1    J2  PDP     A    A1A12    J7   61    67  CONN/I
W42 M-FAN    A1A2    J1  PDP     A    A1A12    J2   61    67  CONN/I
W43 M-FAN    A1A2    J2  PDP     A    A1A12    J6   61    67  CONN/I
W44 PDP      A1A12   J3  CHAN    B    A2A1     J1   61    67  RACK
                                                              B
W47 PDP      A1A12   J4  M-FAN   B    A2A2     J2   61    67  RACK
                                                              B
W53 DISK     A1A5    J1  MAINS   A    A1A7     J3   61    67  DISCON/I
W58 PDP      A1A12   J5  ADAP-P  C    A3A5A23  J1   61    67  RACK
                                                              C
W59 MAINS    A1A7    J4  PLF     A    A1A13    J5   61    67  CON/I
W60 PLF      A1A13   J3  MAINS   B    A2A9     J4   61    67  RACK
                                                              B
W61 PLF      A1A13   J1  MAINS   C    A3A10    J4   61    67  RACK
                                                              C
W62 MAINS    A1A7    J1  PLF     B    A2A13    J5   61    67  CON
W68 MAINS    A1A7    J2  PDP     A    A1A12    *    61    67  CON
W88 DISK     A1A5    *   CHAN    B    A2A1     *    62    57  DISCON


             *  part of unit




T̲a̲b̲l̲e̲ ̲5̲.̲8̲.̲3̲





R̲A̲C̲K̲ ̲B̲  

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ M̲o̲d̲u̲l̲e̲ R̲a̲c̲k̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ I̲l̲l̲u̲s̲
 D̲i̲a̲g̲ N̲o̲t̲e̲s̲ ̲ ̲

W44 CHAN     A2A1    J1   PDP    A    A1A12    J3   61    67  DISCON
W45 CHAN     A2A1    J2   PDP    C    A3A15    J3   61    67  DISCON
W46 M-FAN    A2A2    J1   PDP    C    A3A15    J4   61    67  DISCON
W47 M-FAN    A2A2    J2   PDP    A    A1A12    J4   61    67  DISCON
W52 MAINS    A2A9    J2   WD     B    A2A4     J1   61    67  DISCON/I
W54 DISK     A2A7    J1   PDP    B    A2A12    J2   61    67  DISCON/I
W56 FD       A2A6    J1   PDP    B    A2A12    J1   61    67  CON/I
W60 MAINS    A2A9    J4   PLF    A    A1A13    J3   61    67  DISCON
W62 PLF      A2A13   J5   MAINS  A    A1A7     J1   61    67  RACK
                                                              A
W63 MAINS    A2A9    J1   PLF    B    A2A13    J3   61    67  DISCON/I
W64 PLF      A2A13   J1   MAINS  C    A3A10    J1   61    67  RACK
                                                              C
W67 MAINS    A2A9    J3   PDP    B    A2A12    *    61    67  DISCON
W88 CHAN     A2A1    1)   DISK   A    A1A5     2)   62    57  DISCON
W89 CHAN     A2A1    1)   DISK   B    A2A7     2)   62    57  DISCON
W90 CHAN     A2A1    1)   DISK   C    A3A8     2)   62    57  DISCON


    *  part of unit


    1)  DC ground wire terminated to channel-crate right
        hand rear side above CIA-A.

    2)  DC ground wire terminated to rear side of disks.…86…1
           …02…        …02…       …02…    …02…      …02…    …02…        …02…    …02…  
          …02…   …02…           
T̲a̲b̲l̲e̲ ̲5̲.̲8̲.̲4̲





R̲A̲C̲K̲ ̲C̲     

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ M̲o̲d̲u̲l̲e̲ R̲a̲c̲k̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ I̲l̲l̲u̲s̲
 D̲i̲a̲g̲ N̲o̲t̲e̲s̲ ̲ ̲ ̲

W45 PDP    A3A15     J3  CHAN    B    A2A1     J2   61    67  RACK
                                                              B
W46 PDP    A3A15     J4  M-FAN   B    A2A2     J1   61    67  RACK
                                                              B
W48 PROC   A3A1      J1  PDP     C    A3A15    J1   61    67  DISCON/I
W49 PROC   A3A1      J2  PDP     C    A3A15    J7   61    67  DISCON/I
W50 M-FAN  A3A2      J1  PDP     C    A3A15    J2   61    67  DISCON/I
W51 M-FAN  A3A2      J2  PDP     C    A3A15    J6   61    67  DISCON/I
W55 DISK   A3A8      J1  MAINS   C    A3A10    J3   61    67  DISCON/I
W57 ADAP-P A3A5A22   J1  PDP     C    A3A17    J2   61    67  I
W58 ADAP-P A3A5A23   J1  PDP     A    A1A12    J5   61    67  DISCON
W61 MAINS  A3A10     J4  PLF     A    A1A13    J1   61    67  DISCON
W64 MAINS  A3A10     J1  PLF     B    A2A13    J1   61    67  DISCON
W65 PDP    A3A15     J5  PDP     C    A3A17    *    61    67  CON
W66 MAINS  A3A10     J2  PDP     C    A3A15    *    61    67  DISCON
W69 PDP    A3A17     J1  S-FAN   C    A3A7     *    61    67  CON
W90 DISK   A3A8      *   CHAN    B    A2A1     *    62    57  DISCON

           *  part of unit




T̲a̲b̲l̲e̲ ̲5̲.̲8̲.̲5̲





R̲A̲C̲K̲ ̲D̲       

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ M̲o̲d̲u̲l̲e̲ R̲a̲c̲k̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ I̲l̲l̲u̲s̲
 D̲i̲a̲g̲ N̲o̲t̲e̲s̲

W301        ASSY 4  A1A1  J15    PDP  D        A1A19     J3   173         224 CON/I
W302        ADAP-P  A1A1A20      J1   PDP      D    A1A19     J4          173 224 CON/I
W303        ASSY 3  A1A3  J15    PDP  D        A1A19     J1   173         224 CON/I
W304        ADAP-P  A1A3A20      J1   PDP      D    A1A19     J2          173 224 CON/I
W305        ASSY 2  A1A7  J15    PDP  D        A1A27     J3   173         224 CON/I
W306        ADAP-P  A1A7A20      J1   PDP      D    A1A27     J4          173 224 CON/I
W307        ASSY 1  A1A9  J15    PDP  D        A1A27     J1   173         224 CON/I
W308        ADAP-P  A1A9A20      J1   PDP      D    A1A27     J2          173 224 CON/I
W331        MAINS   A1A12 J4     PLF  E        A2A26     J2   173         224 CON
W332        MAINS   A1A12 J1     PLF  E        A2A26     J4   173         224 CON
W351        PDP     A1A19 J5     S-FAN         D    A1A5 *    173         224 CON
W352        MAINS   A1A12 J2     PDP  D        A1A19     *    173         224 CON
W353        PDP     A1A27 J5     S-FAN         D    A1A11     *           173 224 CON
W354        MAINS   A1A12 J3     PDP  D        A1A27     *    173         224 CON


            *  part of unit





T̲a̲b̲l̲e̲ ̲5̲.̲8̲.̲6̲





R̲A̲C̲K̲ ̲E̲  

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ M̲o̲d̲u̲l̲e̲ R̲a̲c̲k̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ I̲l̲l̲u̲s̲
 D̲i̲a̲g̲ N̲o̲t̲e̲s̲ ̲ ̲ ̲

W309        ASSY 8   A2A1 J15    PDP  E        A2A18     J3   173         224 DISCON/I
W310        DAP-P    A2A1A20     J1   PDP      E    A2A18     J4          173 224 DISCON/I
W311        ASSY 7   A2A3 J15    PDP  E        A2A18     J1   173         224 CONN/I
W312        ADAP-P   A2A3A20     J1   PDP      E    A2A18     J2          173 224 CONN/I
W313        ASSY 6   A2A7 J15    PDP  E        A2A24     J3   173         224 CONN/I
W314        ADAP-P   A2A7A20     J1   PDP      E    A2A24     J4          173 224 CONN/I
W315        ASSY 5   A2A9 J15    PDP  E        A2A24     J1   173         224 CONN/I
W316        ADAP-P   A2A9A20     J1   PDP      E    A2A24     J2          173 224 CONN/I
W331        PLF      A2A26       J2   MAINS    D    A1A12     J4          173 224 RACK
                                                                                  D
W332        PLF      A2A26       J4   MAINS    D    A1A12     J1          173 224 RACK
                                                                                  D
W333        MAINS    A2A12       J4   PLF      E    A2A26     J6          173 224 DISCON/I
W334        MAINS    A2A12       J1   PLF      E    A2A26     J1          173 224 DISCON/I
W335        PLF      A2A26       J3   MAINS    F    A3A9 J1   173         224 RACK
                                                                              F
W336        PLF      A2A26       J5   MAINS    F    A3A9 J4   173         224 RACK
                                                                              F
W355        PDP      A2A18       J5   S-FAN    E    A2A5 *    173         224 CONN
W356        MAINS    A2A12       J2   PDP      E    A2A18     *           173 224 DISCON
W357        PDP      A2A24       J5   S-FAN    E    A2A11     *
                                                                          173 224 CONN
W358        MAINS    A2A12       J3   PDP      E    A2A24     *           173 224 DISCON


            *  part of unit



T̲a̲b̲l̲e̲ ̲5̲.̲8̲.̲7̲





R̲A̲C̲K̲ ̲F̲

                           G̲O̲I̲N̲G̲ ̲T̲O̲/̲C̲O̲M̲I̲N̲G̲ ̲F̲R̲O̲M̲
Cable 
 ̲N̲o̲ ̲ ̲ M̲o̲d̲u̲l̲e̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ M̲o̲d̲u̲l̲e̲ R̲a̲c̲k̲ L̲o̲c̲a̲t̲i̲o̲n̲ J̲-̲N̲o̲ I̲l̲l̲u̲s̲
 D̲i̲a̲g̲ N̲o̲t̲e̲s̲ ̲

W317        ASSY10   A3A1 J15    PDP  F        A3A15     J3   173         224 CON/I
W318        ADAP-P   A3A1A20     J1   PDP      F    A3A15     J4          173 224 CON/I
W319        ASSY 9   A3A3 J15    PDP  F        A3A15     J1   173         224 CON/I
W320        ADAP-P   A3A3A20     J1   PDP      F    A3A15     J2          173 224 CON/I
W321        ASSY-11  A3A18       J15  PDP      F    A3A21     J1          173 224 CON/I
W322        ADAP-P   A3A18A20    J1   PDP      F    A3A21     J2          173 224 CON/I
W335        MAINS    A3A9 J1     PLF  E        A2A26     J3   172         224 DISCON
W336        MAINS    A3A9 J4     PLF  E        A2A26     J5   172         224 CON/I
W360        PDP      A3A15       J5   S-FAN    F    A3A5 *    173         224 DISCON
W361        MAINS    A3A9 J2     PDP  F        A3A15     *    173         224 DISCON
W364        PDP      A3A21       J7   S-FAN    F    A3A20     *           173 224 DISCON
W365        MAINS    A3A9 J3     PDP  F        A3A21     *    173         224 DISCON

    *part of unit