⟦8addd0e55⟧ Wang Wps File

    Length: 3206 (0xc86)
    Types: Wang Wps File
    Notes: Spelunked
    Names: »~ORPHAN46.00«

Derivation

└─⟦b169c229b⟧ Bits:30006209 8" Wang WCS floppy, CR 0327A
    └─ ⟦this⟧ »~ORPHAN46.00« 

WangText

…00……00……00……00……00….…02……00……00….
.…07…-…08…-…0d…-…02…,…08…,…0d…,…02…,…07…+…0c…+…01…+…06…*…09…*…0d…*…01…*…05…)…08…)…0d…)
(…08…(…0c…(…02…(…07…'…0d……86…1                                             …02…           …02…   …02…   

…0e…    3779A/lbe     …02… CPS/AUX/065

…02… SPN/830601…02……02…#
CAMPS INSTALLATION PROCEDURES
SITE 10…02……02… CAMPS…0f…







5.9      P̲O̲W̲E̲R̲ ̲U̲P̲ ̲A̲N̲D̲ ̲C̲H̲E̲C̲K̲ ̲O̲U̲T̲

         Before powering up, verify that a̲l̲l̲ ̲s̲w̲i̲t̲c̲h̲e̲s̲ on a̲l̲l̲
         e̲q̲u̲i̲p̲m̲e̲n̲t̲ are i̲n̲ ̲p̲o̲s̲i̲t̲i̲o̲n̲ ̲o̲f̲f̲ or O.



5.9.1    G̲r̲o̲u̲n̲d̲i̲n̲g̲s̲

         a)  Measure with an Ohm-meter that no shor circuit
             exists between the safety group (cabinets) and
             the lines of circuit no. 1 through 9 and 1a through
             3a.

         b)  Remount the lids of the power line filters by the
             30 screws.

         c)  Measure with an Ohm-meter if the "Equipment Frame
             Ground" (cabines) is isolated from the "Signal
             Ground" (5V return).

             The "Signal Ground" (GND) is found on the CCA-panel,
             refer to Figure 5.9.1.

         d)  Start the powering up in the below sequence, starting
             at the CAMPS power distribution board (PDB):



5.9.2    C̲A̲M̲S̲ ̲P̲D̲B̲

         T̲U̲R̲N̲ ̲O̲N̲:    Main circuit breaker

         T̲U̲R̲N̲ ̲O̲N̲:    Miniature circuit breakers

         C̲H̲E̲C̲K̲O̲U̲T̲:   No fuses in the CAMPS PDB blown due to
                     short circuit in the installation.






















































                       Figure 5.9.1
Front Layout for CCA…86…1         …02…   …02…   …02…   …02…   …02…   …02…   …02…   …02…                       
    
5.9.3    F̲r̲e̲q̲u̲e̲n̲c̲y̲ ̲S̲t̲a̲b̲i̲l̲i̲z̲e̲r̲s̲ ̲a̲n̲d̲ ̲D̲i̲s̲k̲ ̲D̲r̲i̲v̲e̲s̲

         To examine that the 3 disk drives are supplied from
         3 separate phases via the frequency stabilizers proceed
         in the below sequence:

         a   F̲r̲e̲q̲u̲e̲n̲c̲y̲ ̲S̲t̲a̲b̲i̲l̲i̲z̲e̲r̲ ̲#̲1̲/̲D̲i̲s̲k̲ ̲#̲1̲ ̲(̲M̲M̲D̲)̲ ̲R̲A̲C̲K̲ ̲A̲

             1)  T̲U̲R̲N̲ ̲O̲N̲:    Input power switch on front of
                             the stabilizer (A1A3)(see CAMPS
                             H/W Breakdown page 344).

                             Set the rotary switch on the by-pass
                             panel to position "frequency stabilizer".

             2)  C̲H̲E̲C̲K̲:  Input power and fault lamp lit. Wait
                         2-3 seconds for fault lamp to extinguish.
                         "Power out" lamp lit.
                 

             3)  T̲U̲R̲N̲ ̲O̲N̲:    Power switch 1 (left hand) on the
                             front of the main switch located
                             in the bottom of rack A.

             4)  C̲H̲E̲C̲K̲:      "Power on" lamp lit onmain switch.

             5)  T̲U̲R̲N̲ ̲O̲N̲:̲    Rear power switch disk drive No.
                             1 located in rack A.

             6)  C̲H̲E̲C̲K̲:      Disk running and "ready" lamp in
                             front of disk lit (wait for 
                             30 sec.).

             7)  T̲U̲R̲N̲ OFF:   Miniature circuit breaker (CAMPS
                             PDB) corresponding to powr circuit
                             no. 1 for freq. stab. 1 and disk
                             1 (see ATBB drawing 120).

             8)  C̲H̲E̲C̲K̲:      Disk 1 and freq. stab. 1 powered
                             down.

             9)  Leave the miniature circuit breaker in position
                 OFF.


         b)  F̲r̲e̲q̲u̲e̲n̲c̲y̲ ̲S̲t̲a̲b̲i̲l̲i̲z̲e̲r̲ ̲#̲2̲ ̲a̲n̲d̲ ̲D̲i̲s̲k̲ ̲#̲2̲ ̲(̲S̲M̲D̲)̲

             Repeat step 5.9.3a-1 through a-4 for frequency
             stab. #2 (A1A5) and disk drive #2 (rack B).

             5)  T̲U̲R̲N̲ ̲O̲N̲:̲    Rear switches "AC power" nd "power
                             supply".

             6)  C̲H̲E̲C̲K̲:̲      Disk running. (No ready lamp if
                             no disk pack mounted).

         Proceed by repeating step 5.9.3a-7 thru a-9 for 
         circuit no. 2.

         c)  F̲r̲e̲q̲u̲e̲n̲c̲y̲ ̲S̲t̲a̲b̲i̲l̲i̲z̲e̲r̲ ̲#̲3̲ ̲a̲n̲d̲ ̲D̲i̲s̲k̲ ̲#̲3̲ ̲(̲M̲M̲D̲)̲

             Repeat step 5.9.3 a-1 through a-9 for frequncy
             stab. #3 (A1A7), circuit no. 3, and disk drive
             #3 (rack C).

         d)  Turn on the 3 miniature circuit breakers in the
             CAMPS PDB one by one.

         e)  Check that all frequency stabilizers and disks
             are operating.

         f)  By-pass the freq. stab. by positionin