WangText

f the state to which the transaction has been recovered after switch over.

 c) A switch over initiated by the detection of an error, shall normally not require
    operator intervention.



3.2.8.5 D̲e̲g̲r̲a̲d̲e̲d̲ ̲A̲v̲a̲i̲l̲a̲b̲i̲l̲i̲t̲y̲ ̲C̲o̲n̲f̲i̲g̲u̲r̲a̲t̲i̲o̲n̲

 a) It is acceptble, that redundant modules are withdrawn from use in the operational
    configuration. The hereby obtained configuration is named: degraded availability
    configuration.

 b) The degraded availability configuration may be entered in order to perform an
    of the following actions:

  1) preventive maintenance
  2) loading and checkout of new software
  3) execution of diagnostics programs
  4) on-job training

 c) Any of the above mentioned action shall not result in interruption in the normal
    messge handling function.

 d) An error in the degraded availability configuration shall be handled as a total
    system error (refer to section 3.2.8.4.1).

 e) It shall be possible to reintegrate withdrawn modules into the operational configuration
    and eturn them to service within 5 minutes with a minimum of operator action.

 f) For preventive maintenance actions requiring longer than this time, sufficient
    units shall be provided to maintain the overall availability of the equipment.

 g) If swi