⟦9587f44df⟧ Wang Wps File

    Length: 59675 (0xe91b)
    Types: Wang Wps File
    Notes: PC/TPR/001                
    Names: »4254A «

Derivation

└─⟦8c51ee17f⟧ Bits:30006241 8" Wang WCS floppy, CR 0383A
    └─ ⟦this⟧ »4254A « 

WangText



&…05…&…07…%…0e…%
%…06…$…0c…$…0f…$…01…$…07…#…0c…#…02…#…07…"…0b…"…0c…"…0d…"…01…"…02…"…07…!…08…!…09…!…0a…!…0f……86…1
      
      
      
      
      
      
      
   …02…   
      
  …02…   …02… 
      
 

…02…PC/TPR/001

…02…BHE/831031…02……02…#
PROTOCOL
 CONVERTER
TEST PROCEDURES…02…BHE/830729…02…
   PC












                 PROTOCOL CONVERTER
                 ACCEPTANCE TEST PROCEDURES
                 CONTRACT SHNMO-82-9205-INF


                 PC/TPR/001













                 DJON LARSEN and B[RGE HERMANSEN





                 B[RGE HERMANSEN







                 SHAPE (12), GJ, DL, KPL, SN[, ALF,
                 EHO, PMO, BS, EV, BHE, GQAR, FILE (1)















                              


         2.1



         831031         …0f…  CR QA          830630



                                               PC/TPR/001

…02…BHE/831031…02…   ii
PROTOCOL CONVERTER
TEST PROCEDURES…02…BHE/830729    PC 
…0f…












       830210                   All        Initial issue of
                     Document



            …02…PC/TPR/001

…02…BHE/831031…02…                                   iii
PROTOCOL CONVERTER 
TEST PROCEDURES…02…BHE/830729 …02…     PC










                                      T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲


                                                        Page
     1.  GENERAL ....................................  1
         

       1.1 PURPOSE ..................................  1
           
       1.2 REFERENCED DOCUMENTS .....................  2
           
       1.3 APPLICABLE DOCUMENTS .....................  4
           
       1.4 ABBREVIATIONS . ..........................  5
           
       1.5 TERMS ....................................  7
           
       1.6 DOCUMENT LAYOUT ..........................  8
           
         1.6.1 Section 2 ............................  8
               
         1.6.2 Section 3 ............................  8
               
         1.6.3 Appendices A and B....................  8
               
           1.6.3.1 Test Overview ....................  9
                   
           1.6.3.2 Test Steps .......................  9
                   

     2.  TEST SPECIFICATION AND EVALUATION .......... 12
         

       2.1 TEST OBJECT IDENTIFICATION ............... 14
           
         2.1.1 In-Plant Verification ................ 14
               
         2.1.2 On-Site Verification ................. 14
               

       2.2 VERIFICATION METHODS AND CONSTRAINTS ..... 18
           
         2.2.1 System Verification Conditions ....... 18
               
           2.2.1.1 Conditions at FAT ................ 18
                   
           2.2.1.2 Conditions at PAT ................ 18
                   
           2.2.1.3 Conditions at PSAT ............... 18
                   

         2.2.2 Verification Method Terms ............ 19
               
         2.2.3 Data Recording ....................... 19
               





                                                       Page

     3.  VERIFICATION STRUCTURE ..................... 20
         

       3.1 TEST CONTROL ............................. 22
           
       3.2 TEST GROUP DESCRIPTION ................... 24
           
         3.2.1 Test Group 1 ......................... 30
               
         3.2.2 Test Group 2 ......................... 30
               
         3.2.3 Test Group 3 ......................... 30
               
         3.2.4 Test Group 4 ......................... 31
               
         3.2.5 Test Group 5 ......................... 31
               
 
       3.3 TEST GROUPS .............................. 38
           
         3.3.1 TEST GROUP NO. 1 ..................... 38
               
         3.3.2 TEST GROUP NO. 2 ..................... 42
               
         3.3.3 TEST GROUP NO. 3 ..................... 44
               
         3.3.4 TEST GROUP NO. 4 ..................... 45
               
         3.3.5 TEST GROUP NO. 5 ..................... 53
               

       3.4 FUNCTION/TEST RELATIONSHIP ............... 54
           

     A̲p̲p̲e̲n̲d̲i̲c̲e̲s̲

       Appendix A: In-Plant Acceptance Test Procedures

       Appendix B: On-Site  Acceptance Test Procedures





                        1̲ ̲ ̲G̲E̲N̲E̲R̲A̲L̲


         Test Procedures comprise a baseline for the Acceptance
         Tests of the Protocol Converter to be developed under
         SHNMO contract 82-9205-INF.



1.1      P̲U̲R̲P̲O̲S̲E̲

         The purpose of this document is:

         a)  to identify:

             1)  the Test Object
             2)  the requirements to be verified
             3)  the system functions to be exercised

         b)  to define:

             1)  the verification methods and constraints
             2)  the verification evaluation criteria

         c)  to describe:

             1)  verification control
             2)  the detailed procedure for test execution





1.2      R̲E̲F̲E̲R̲E̲N̲C̲E̲D̲ ̲D̲O̲C̲U̲M̲E̲N̲T̲S̲

         1.  Protocol Converter contract SHNMO-82-9205-INF.
             1982-04-29.

         2.  System Requirement Specification (SRS).
             Appendix G of Reference 1. 1982-04-29.

         3.  SCARS II System Design Baseline Vol III A
             Rev A, B, and C 1981-06-30, 1981-07-15, 1981-04-28.
             Burroughs or
             CPS/ICD/006, 1981-11-10 Christian Rovsing A/S

         4.  Functional Description for the SCARS, CAMPS, ACCIS
             interface. 1981-02-05. As appendix E to Reference
             3.

…02…5.       Remote Terminal Supervisor (GRTS).
             Honeywell DD40B rev. 0, July 1976.

         6.  DINDAC  CCTC TR-01, 1978-06-30.

         7.  ACE Security Directive 70-1.
             1979-08-31 with change 2 dated 1981-02-06.

         8.  CCITT ORANGE BOOK,Volume VIII. 1.2
             V.24 and V.28 Recommendations

         9.  AMSG 720A. January 1977.

         10. AMSG 719B. September 1976.

         11. Not used

         12. MIL-STD-188C. 1969-11-24.

         13. WWMCCS ADP Telecom Standard Engineering Practices,
             DCA November 1979.

         14. Control wires and functions for WWMCCS-PC link
             (delivery by SHAPE on or before 3. May 1982).

         15. X25 LAP (CAMPS) Product Specification.
             CSS-MIC/0422/PSP/1027. 1982-05-28. Chr. Rovsing
             A/S.

         16. DINDAC Interface Parameter Document.
             Telex: CAMPS log. 631, PC log 002. SHAPE 1982-05-11.



         17. Protocol Converter, System Specification,
             PC/SDS/001, issue 2.3

         18. DINDAC-RCI Protocol Notes, 1982-07-26,
             (Handout from M. Novell, SHAPE)

         19. Not used

         20. PC Equipment Handbook
             PC/HBK/001

         21. PC Hardware Assembly Breakdown
             PC/SDS/002

         22. PC, Package Design Specification, issue 1.2
             PC/PDS/001

         23. Site Inventory Checklist

         24. DSMT Hardware Test Report, CPS/TRP/004

         25. CPU-SCM ADAPTER, CSA
             Product Specification, CSD/005/PSP/0056

         26. V28 L/L Adapter
             Technical Manual, CPS/TCM/024

         27. Site Inventory Checklist

         28. TESTPROCEDURE, CCIS TESTMESSAGES
             PC/AUX/004


1.3      A̲P̲P̲L̲I̲C̲A̲B̲L̲E̲ ̲D̲O̲C̲U̲M̲E̲N̲T̲S̲

         a)  Protocol Converter contract SHNMO-82-9205-INF.
             1982-04-29.

         b)  System Requirement Specification (SRS).
             Appendix G of Reference 1. 1982-04.29.

         c)  Protocol Converter, Acceptance Test Plan, issue
             3
             PC/TPL/001

         d)  CR Product Assurance Plan
             PAD/PLN/0001







1.4      A̲b̲b̲r̲e̲v̲i̲a̲t̲i̲o̲n̲s̲


         A              Verification method A
         ACE            Allied Commands Europe
         App            Appendix
         ATTN           Symbol for the "BREAK"-key on the VDU
         Aux No.        Number of a testmessageas defined in
                        PC/AUX/004 document

         B              Verification method B
         Baud           "Information-Bits" per second
         BD             Bogus Data
         BFD            Bona Fide Data
         bps            Bits Per Second

         C              Verification method C
         CAMPS          Computer Aided Message Processing System
         CCIS           Command and Control Information System
         CCITT          International Telegraph and Telephone
                        Consultative Committee
         COMSEC         Communications Security
         CPU            Central Processing Unit
         CR             Christian Rovsing A/S
         CR80           CR80 minicomputer (Christian Rovsing)
         CSA            CPU/SCM Adapter
         cr             "RETURN"-key on the VDU

         D              Verification method D
         DINDAC         autoDIN-wwmccs Direct Access 
         DN355          Honeywell front-end processor
         Doc            Document
         DSMT                 

         E1             Transmission format
         ECO            Engineering Change Order
         EMI            Electro Magnetic Interference
         End Systems    CCIS,CAMPS, or SCARS
         EPROM          Erasable Programmable Read-Only Memory
         Equipm         Equipment

         FAT            Factory Acceptance Test
         Funct          Functional

         GRTS           General Remote Terminal System
         G.F.C.         Group.Function.Case; Test Case number.

         HBK            PC/HBK/001 document
         HDRTYP         Header type
         H/W            Hardware



         Info           Information
         Init           Initialize S/W System
         Instal         Installation
         I/O            Input/Output

         L              Local mode
         LIA-N          Line Interface Adapter - Non switching
         LTU            Line Terminating Unit
         L/L            Low level / Long distance driving

         M              Maintenance mode
         Mem            Memory
         Min            Minute(s)
         M&D            Maintenance and Diagnostics

         NATO           North Atlantic Treaty Organization
         No.            Number

         O              Operational mode
         OC             Operator's Console

         PAT            Preliminary Acceptance Test
         Para           Paragraph
         Pasw           Password
         PC             Protocol Converter
         PSAT           Provisional Site Acceptance Test
         PU             Processor Unit, CR831

         RAM            Random Access Memory
         RCI            Remote Computer Interface (to Honeywell)
         Ref            Reference document -or- Refer to
         Req            Requirement
         Rev.           Revision

         SCAMPS         SCARS and/or CAMPS
         SCARS          Status & Control Alerting & Reporting
                        System
         SCM            System Control Mode
         SDS            System Specification, (ref. 17)
         Sec            Second(s)
         SHAPE          Supreme Headquarters Allied Powers Europe
         SHNMO          SHAPE Host Nation
         Spec           Special
         SRS            System Requirement Specification (ref.
                        2)
         SS             Reference document no. 3
         SUSDUP         Suspected Duplicate
         SWELL          Software Engineering Low Level Language
         S/W            Software

         T              Test mode
         TRC            Traffic Controller



         V24            CCITT Recommendation (ref. 8)
         V28            CCITT Recommendation (ref. 8)
         V28 L          V28 Low level interface, see Terms
         VDU            Visual Display Unit (Delta Data 7260TC)
         Verif          Verification
         Vol.           Volume (of document)

         WWMCCS         World Wide Military Command & Control
                        System

         XXX            Replaces 3 numbers
         X.25           CCITT Recommendation (ref. 15)






1.5      T̲e̲r̲m̲s̲

         Mode:             Designates a system state with certain
                           capabilities.

         Verification:     Designates the task of verify the
                           fulfilment of certain requirements,
                           using one of the four methods defined
                           in sub-
                           section 2.2.2.

         Acceptance Test:  Designates the act whereby SHAPE
                           will acknowledge that CR has demonstrated,
                           that the requirements to PC has been
                           met, to a level set by the appropriate
                           Acceptance Test Procedure.

         Operator:         Designates the person, who operates
                           the PC-System Supervisor/maintenance
                           functions by means of the maintenance-VDU.

         End-System:       Designates any of the three systems
                           to which PC is connected, i.e. CAMPS
                           or SCARS in one end and CCIS in the
                           other end.

         V28 L/L:    Designates the V̲2̲8̲ recommendation implemented
                     with L̲o̲w̲ Voltage Levels and L̲o̲n̲g̲ distance
                     driving ability (up to 275 m). In practice
                     it is implemented as the MIL-STD-188C (ref.
                     12) with reversed polarity on data and
                     clock circuit lines.


1.6      D̲O̲C̲U̲M̲E̲N̲T̲ ̲L̲A̲Y̲O̲U̲T̲



1.6.1    S̲e̲c̲t̲i̲o̲n̲ ̲2̲ 

         Section 2 of this document contains a general Test
         Specification, naming the Test Object and the methods
         of verification.


1.6.2    S̲e̲c̲t̲i̲o̲n̲ ̲3̲ 

         Section 3 explains the structure of verification, naming
         the Test Groups and containing an overview to the configurations
         and Test Cases. Furthermore, it gives an equipment
         overview and a list of requirements for each of five
         Test Groups. At the end of section a Function/Test
         Matrix is shown.


1.6.3    A̲p̲p̲e̲n̲d̲i̲c̲e̲s̲ ̲A̲ ̲a̲n̲d̲ ̲B̲

         Together with the document two appendices are included,
         each containing the step-by-step procedure to accomplish
         the verification of the system.

         o   A̲p̲p̲e̲n̲d̲i̲x̲ ̲A̲,̲ describes the In-Plant Acceptance Test
                                                       procedures.

         o   A̲p̲p̲e̲n̲d̲i̲x̲ ̲B̲, describes the On-Site Acceptance Test
                                                       procedures.


         Two kinds of Forms are used for the step-by-step Test
         procedures, located in the appendices:

         -   Test overview
         -   Test steps




1.6.3.1  T̲e̲s̲t̲ ̲O̲v̲e̲r̲v̲i̲e̲w̲

         The Test Overview Form is used to identify the Test
         Cases required (see Figure 1.6-1). Each identified
         Test Case is described in details on the Test Steps
         Form.



1.6.3.2  T̲e̲s̲t̲ ̲S̲t̲e̲p̲s̲

         The Test Step Form contains the procedure for execution
         of the Test Cases (see Figure 1.6-2). The procedure
         for each Test Case is described by the information
         in the columns of the Test Step Form:

         o   STEP identifies the step in the appropriate verification.

         o   ACTION & INPUTS describes in a short form the action
             required by the operator and the applied inputs.
             

         o   EXPECTED RESULTS column details the expected results.

         o   CHECK for checklisting the procedure.



















































                       FIGURE 1.6-1
                    TEST OVERVIEW FORM




















































                       FIGURE 1.6-2
                      TEST STEP FORM




           2̲ ̲ ̲T̲E̲S̲T̲ ̲S̲P̲E̲C̲I̲F̲I̲C̲A̲T̲I̲O̲N̲ ̲A̲N̲D̲ ̲E̲V̲A̲L̲U̲A̲T̲I̲O̲N̲


         Acceptance Testing of the Protocol Converter is performed
         on two different locations, in seven Test Phases.

         The PC shall pass the following Test Phases:


         I̲N̲-̲P̲L̲A̲N̲T̲    FACTORY ACCEPTANCE TEST,           F̲A̲T̲

         1.PHASE:    IN-PLANT FUNCTIONAL VERIFICATION
         2.PHASE:    IN-PLANT COMSEC VERIFICATION


         O̲N̲-̲S̲I̲T̲E̲     PRELIMINARY ACCEPTANCE TEST        P̲A̲T̲

         3.PHASE:    CCIS, FUNCTIONAL VERIFICATION
         4.PHASE:    SECURITY CERTIFICATION


         O̲N̲-̲S̲I̲T̲E̲     PROVISIONAL SITE ACCEPTANCE TEST,  P̲S̲A̲T̲

         5.PHASE:    FUNCTIONAL SITE ACCEPTANCE TEST,CAMPS
         6.PHASE:    FUNCTIONAL SITE ACCEPTANCE TEST,SCARS
         7.PHASE:    ON-SITE COMSEC VERIFICATION

         CR has the overall responsibility of phases 1, 3, 5
         and 6 while SHAPE is to conduct phases 2, 4 and 7.


















































                        FIGURE 2-1
                   TEST PLAN HIERARCHY





2.1      T̲E̲S̲T̲ ̲O̲B̲J̲E̲C̲T̲ ̲I̲D̲E̲N̲T̲I̲F̲I̲C̲A̲T̲I̲O̲N̲



2.1.1    I̲n̲-̲P̲l̲a̲n̲t̲ ̲V̲e̲r̲i̲f̲i̲c̲a̲t̲i̲o̲n̲

         At the Factory Acceptance Test the Test Object is the
         Protocol Converter H/W and S/W in a simulated environment,
         i.e. verification of all PC features using a PC-CAMPS
         link, but also including features, which are not relevant
         or feasible to verify at the On-Site Tests (e.g. design
         concepts and bogus data flow). The FATs serve as a
         validation of each PC system before installation on
         site. The PC H/W and S/W systems are depicted in Figures
         2.1-1 and 2.1-2.



2.1.2    O̲n̲-̲S̲i̲t̲e̲ ̲V̲e̲r̲i̲f̲i̲c̲a̲t̲i̲o̲n̲

         a)  The Preliminary Acceptance Test is only performed
             on site 1 (SHAPE). The Test Object of the PAT is
             the PC-equipment connected to the CCIS system with
             a CAMPS as supporting equipment, i.e. the purpose
             is a "real-life" verification of the PC-CCIS link.

         b)  At the Provisional Site Acceptance Test the Test
             Object is the CAMPS/SCARS-PC-CCIS links in order
             to make the final functional test of the PC-system.






















































               F̲I̲G̲U̲R̲E̲ ̲2̲.̲1̲-̲1̲  (Sheet 1 of 2)

             PROTOCOL CONVERTER CONFIGURATION



















































              F̲I̲G̲U̲R̲E̲ ̲2̲.̲1̲-̲1̲\  (Sheet 2 of 2)

                  PC RACK CONFIGURATION



















































                       F̲I̲G̲U̲R̲E̲ ̲2̲.̲1̲-̲2̲

                    PC SOFTWARE SYSTEM



2.2      V̲E̲R̲I̲F̲I̲C̲A̲T̲I̲O̲N̲ ̲M̲E̲T̲H̲O̲D̲S̲ ̲A̲N̲D̲ ̲C̲O̲N̲S̲T̲R̲A̲I̲N̲T̲S̲



2.2.1    S̲y̲s̲t̲e̲m̲ ̲V̲e̲r̲i̲f̲i̲c̲a̲t̲i̲o̲n̲ ̲C̲o̲n̲d̲i̲t̲i̲o̲n̲s̲



2.2.1.1  C̲o̲n̲d̲i̲t̲i̲o̲n̲s̲ ̲a̲t̲ ̲F̲A̲T̲

         The verification will be conducted on a Protocol Converter
         at the CR-factory in Ballerup by a CR Test Engineer.
         The input data from the CAMPS side is a representative
         batch of messages varying in type, precedence and classification.
         On the CCIS side where the link is simulated, the same
         set of messages are to be used for the verification.



2.2.1.2  C̲o̲n̲d̲i̲t̲i̲o̲n̲s̲ ̲a̲t̲ ̲P̲A̲T̲

         The Preliminary Site Acceptance Test at SHAPE will
         concentrate upon verification of the PC-CCIS interface
         and the function of the Protocol Converter. The verification
         will use the built-in Test Messages present in the
         Protocol Converter together with the SHAPE supplied
         Test Messages from the CCIS-system.
         (ref. 28).



2.2.1.3  C̲o̲n̲d̲i̲t̲i̲o̲n̲s̲ ̲a̲t̲ ̲P̲S̲A̲T̲

         The Protocol Converter shall be connected to both the
         CCIS-system and the CAMPS-system and a functional verification
         of the PC shall be performed.





2.2.2    V̲e̲r̲i̲f̲i̲c̲a̲t̲i̲o̲n̲ ̲M̲e̲t̲h̲o̲d̲ ̲T̲e̲r̲m̲s̲

         The keeping of the requirements will be verified by
         one of the following methods:

         A   N̲o̲t̲ ̲A̲p̲p̲l̲i̲c̲a̲b̲l̲e̲: No action will be taken.

         B   E̲x̲a̲m̲i̲n̲a̲t̲i̲o̲n̲: This method is a non-functional verification,
             such as visual inspection of the physical characteristics
             of the item or of the documentation associated
             with the item.

         C   A̲n̲a̲l̲y̲s̲i̲s̲: This method is a non-functional verification,
             such as deduction or translation of data, review
             of analytical data, or performance of a detailed
             analysis.

         D   T̲e̲s̲t̲/̲D̲e̲m̲o̲n̲s̲t̲r̲a̲t̲i̲o̲n̲: This method is a functional
             verification, such as actual operation wherein
             the element of verification is instrumented, measured,
             or displayed directly (test) or where the element
             of verification is logically obvious, as the result
             of some other verification, but not itself displayed
             (demonstration).



2.2.3    D̲a̲t̲a̲ ̲R̲e̲c̲o̲r̲d̲i̲n̲g̲

         For the verification of the PC functions, it will be
         necessary to maintain three detailed logs of activities:

         o   Messages sent and received on CAMPS/SCARS
         o   Messages sent and received on CCIS
         o   Messages sent and received on PC

         These logs are to be verified by the supervisor after
         the printing. This is applicable to Test Group 4 where
         End-System are used.






3.       V̲E̲R̲I̲F̲I̲C̲A̲T̲I̲O̲N̲ ̲S̲T̲R̲U̲C̲T̲U̲R̲E̲



         The purpose of the verification is to provide a demonstration
         of the PC functional capability. The verification is
         divided into 5 separate Test Groups:

         G̲R̲O̲U̲P̲ ̲N̲O̲.̲       N̲A̲M̲E̲

            1            System and Start-up
            2            Maintenance Mode
            3            Local Mode
            4            Operational Mode
            5            Test Mode

         In each Test Group, a set of system requirements is
         to be verified using one of the verification methods.

         The verification structure is a 4-level hierarchy:

         o  Test Group
         o  Test Function
         o  Test Case
         o  Test Step

         See the Test Procedure Hierarchy in Figure 3-1.














































           F̲I̲G̲U̲R̲E̲ ̲3̲-̲1̲…01……01…TEST PROCEDURE HIERARCHY


3.1      T̲E̲S̲T̲ ̲C̲O̲N̲T̲R̲O̲L̲

         The test control is related to the TEST STEP form.
         An sample of this form is shown in Figure 3.1-1, when
         it has been filled in.
         Explanations to Figure 3.1-1:

         a)  G.F.C.: 2.2.2     - means that this is Test Group
             2,
                                 Function 2 and case 2.
         b)  TEST CASE: MAINTENANCE, DUMP, BD - is the title
             
                                                of G.F.C.
         c)  STEP:             - is a column containing 
                                   sequential numbering of 
                                 each step.
         d)  ACTION AND INPUT: - contains input.
         e)  EXPECTED RESULTS  - contains output. (a) and (b)
             are
                                 repetition marks, - once stated
                         
                                 at the end of a line, it can
         be
                                 used for repetition of expec-
                                 ted output.
         f)  CHECK             - is a column where Shape shall
                         
                                 fill-in accepting marks:
                                 r - right   (approved)
                                 n - note    (discrepancy)
                                 f - failure (defect)
         g)  COMMENTS:         - is used for explanation of
                                 marks when n or f has been
                                 filled in.
         h)  Test Witnesses:   - is signatures from CR and SHAPE

         If corrective actions to the step-by-step proceeding
         have to be taken, this must be analysed to decide on
         extent of retest for agreement with SHAPE. "Corrective
         action" in such cases may result in the detected fault
         being corrected immediately, causing the test to be
         repeated only in part thus not requiring SHAPE test
         team members to significantly prelonging their engagement
         in the test or the detected fault may cause corrective
         action of longer duration (several days). In the latter
         case, the Contractor will propose an appropriate postponement
         of the test and provide new test dates at which a complete
         acceptance test is to be performed as retest.








                     T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲


     G̲.̲F̲.̲C̲.̲: 2.2.2            

     T̲E̲S̲T̲ ̲C̲A̲S̲E̲: MAINTENANCE, DUMP, BD           


 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
   ^                                ^                        ^
STEP ^                              ACTION AND INPUT 
                                                 ^ EXPECTED
                                    RESULTS       ^ CHECK
 ̲ ̲ ̲ ̲ ̲^̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^̲ ̲ ̲ ̲ ̲ ̲ ̲
   ^                                ^                        ^
  0  ^                              ATTN (button)            ^  (M)
                                                                -   ^ r
  1  ^                              DUMP 00001  000G         ^  PARAMETER
                                                                ERROR
                                                                
                                                                
                                                                
                                                                (a) ^ n
   ^                                ^ (M) -          
                                         (b)                 ^  r
  2  ^                              DUMP 0000G  0010         ^  (a) ^ r
   ^                                ^ (b)                    ^  r
  3  ^                              DUMP 00001               ^
                                                             (a)
                                                             
                                                             
                                                             
                                                             
                                                             
                                                             
                                                             
                                                             
                                                             
                                                             
                                                             
                                                             
                                                             
                                                             
                                                             
                                                                ^   r
     ^                                               
                                      ^                      (b)    ^ r
  4  ^                              DUMP 01 02               ^  (a) ^ f
   ^                                ^ (b)                    ^  r
   ^                                ^                        ^
     ^                                                       ^      ^
   ^                                ^                        ^
   ^                                ^                        ^
   ^                                ^                        ^
     ^                                               
                                      ^                         ^
   ^                                ^                        ^
   ^                                ^                        ^
   ^                                ^                        ^
   ^                                ^                        ^
 ̲ ̲ ̲ ̲ ̲^̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^̲ ̲ ̲ ̲ ̲ ̲ ̲

     Comments:                        Test Witnesses:

     n: - there is double             CR: Jensen
          space between
          PARAMETER and ERROR

     f: - PARAMETER ERROR is          SHAPE: Schmith
          not written at all



                    F̲I̲G̲U̲R̲E̲ ̲3̲.̲1̲-̲1̲

               Example of a filled in
                  TEST STEP form.



3.2      T̲E̲S̲T̲ ̲G̲R̲O̲U̲P̲ ̲D̲E̲S̲C̲R̲I̲P̲T̲I̲O̲N̲

         The verification of PC is partioned in five Test Groups:

         G.F.C.1.   Test of Hardware.
         G.F.C.2.   Test of Software - maintenance mode
         G.F.C.3.   Test of Software - local mode.
         G.F.C.4.   Test of Software - operational mode.
         G.F.C.5.   Test of Software - test mode.

         The Test Groups are constructed with the purpose of
         verifying the functions of PC. The Functional Verification
         is performed in factory and on site. The On Site Verification
         is divided into a Preliminary Acceptance Test(PAT)
         and a Provisional Site Acceptance Test(PSAT). The Test
         Cases for the FAT is stated in Appendix A. The Test
         Cases for PAT and PSAT is stated in Appendix B.

         The selection of Test Cases for each Verification has
         been made under consideration of the unavoidability
         of simulation of End-system and the feasibility of
         construction of testmessages.

         Figure 3.2-1 gives an overview of Tests, End-systems,
         Testdocuments and Testlocations.

         Figure 3.2-2 gives the relations between Group Function
         Case and Appendix/Test.

         After Figure 3.2-2 follows paragraphs 3.2.1 through.
         3.2.5 which describes each Test Group and the environmental
         prerequisite configuration.













         T̲E̲S̲T̲ ̲ ̲ ̲ ̲C̲O̲N̲F̲I̲G̲U̲R̲A̲T̲I̲O̲N̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲D̲O̲C̲U̲M̲E̲N̲T̲ ̲ ̲ ̲ ̲ ̲L̲O̲C̲A̲T̲I̲O̲N̲

         FAT     CAMPS'- PC - CCIS'   App. A       In Plant
         1,2,3

         PAT     CAMPS - PC - CCIS    App. B       On Site 
         1

         PSAT    CAMPS - PC - CCIS    App. B       On Site 
         1,2,3

         PSAT    SCARS - PC - CCIS    App. B       On Site 
         1





         CAMPS' means simulated End-System.
         CCIS'  means simulated End-System.





















                       F̲i̲g̲u̲r̲e̲ ̲3̲.̲2̲-̲1̲

               Configuration Test Overview.


         …01…                            App. A      App.B
         G̲.̲F̲.̲C̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲C̲O̲N̲T̲E̲N̲T̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲F̲A̲T̲ ̲T̲I̲M̲E̲ ̲ ̲ ̲ ̲P̲A̲T̲,̲P̲S̲A̲T̲


         1         HARDWARE                X            X

         1.1       H/W                     X            X

         1.1.1     H/W configuration       X            X

         1.1.2     Maintenance VDU         X            X

         1.2       Design H/W              X            -

         1.2.1     V28 L to CAMPS/SCARS    X            -

         1.2.2     Mil-Std-188C to CCIS    X            -

         1.2.3     Identical H/W, S/W      X            -

         1.2.4     Power Input             X            -

         1.2.5     EPROMS                  X            -

         1.3       Design S/W              X            X

         1.3.1     Modes of Operation      X            X

         1.3.2     PU initialization       X            X

         1.3.3     Keyboard response time  X        5.5.1  
          *)


              *) 'Keyboard response time' is executed in normal
                 sequence in the FAT, but in PAT and PSAT this
                 testcase is to be moved to G.F.C. 5.5.1.







               F̲i̲g̲u̲r̲e̲ ̲3̲.̲2̲-̲2̲ ̲(̲s̲h̲e̲e̲t̲ ̲1̲ ̲o̲f̲ ̲4̲)̲

                     G.F.C. Overview



         …01…                            App. A      App.B
         G̲.̲F̲.̲C̲.̲ ̲ ̲ ̲ ̲ ̲ ̲C̲O̲N̲T̲E̲N̲T̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲F̲A̲T̲ ̲T̲I̲M̲E̲ ̲ ̲ ̲ ̲P̲A̲T̲,̲P̲S̲A̲T̲


         2         MAINTENANCE MODE        X             X

         2.1       CHECK                   X             X

         2.1.1     CR80-modules            X             X

         2.1.2     Parameter errors        X             X

         2.2       DUMP                    X             X

         2.2.1     Core-dump               X             X

         2.2.2     Parameter errors        X             X

         2.3       INIT                    X             X

         2.3.1     From M to L mode        X             X

         3         LOCAL MODE              X             X

         3.1       LOGON                   X             X

         3.1.1     Logon parameters        X             X

         3.1.2     Parameter errors        X             X

         3.2       MAINTENANCE             X             X

         3.2.1     From L to M mode        X             X














               F̲i̲g̲u̲r̲e̲ ̲3̲.̲2̲-̲2̲ ̲(̲s̲h̲e̲e̲t̲ ̲2̲ ̲o̲f̲ ̲4̲)̲

                     G.F.C. Overview



         …01…                            App. A      App.B
         G̲.̲F̲.̲C̲.̲ ̲ ̲ ̲ ̲ ̲ ̲C̲O̲N̲T̲E̲N̲T̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲F̲A̲T̲ ̲T̲I̲M̲E̲ ̲ ̲ ̲ ̲P̲A̲T̲,̲P̲S̲A̲T̲


         4         OPERATIONAL MODE        X             X

         4.1       SHOW STATISTICS         X             X

         4.1.1     Statistics              X             X

         4.2       RESET STATISTICS        X             X

         4.2.1     Reset Statistics        X             X

         4.3       LOGOFF                  X             X

         4.3.1     From O to L mode        X             X

         4.4       TEST                    X             X

         4.4.1     From O to T mode        X             X

         4.5       TRANSMISSION            X             X

         4.5.1     CAMPS/SCARS to CCIS     X             X

         4.5.2     CCIS to CAMPS/SCARS     X             X

         4.5.3     Transmission between
                   CAMPS/SCARS and CCIS    X             X

         4.5.4     Transmission errors     X             X
                   1.  Wrong type          X             X
                   2.  Too long COMMENT    X             X
                   3.  Too long DATA       X             X
                   4.  Embedded message    X             X

         4.6       PERFORMANCE             X             X

         4.6.1     PC processing delay     X             X

         4.6.2     PC throughput           X             X







               F̲i̲g̲u̲r̲e̲ ̲3̲.̲2̲-̲2̲ ̲(̲s̲h̲e̲e̲t̲ ̲3̲ ̲o̲f̲ ̲4̲)̲

                     G.F.C. Overview



                                       App. A      App.B
         G̲.̲F̲.̲C̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲C̲O̲N̲T̲E̲N̲T̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲F̲A̲T̲ ̲T̲I̲M̲E̲ ̲ ̲ ̲ ̲P̲A̲T̲,̲P̲S̲A̲T̲


         5         TEST MODE               X             X

         5.1       VERIFY                  X             X

         5.1.1     Verify End-Systems      X             X

         5.1.2     Parameter errors        X             X

         5.2       SHOW STATISTICS         X             X

         5.2.1     Statistics              X             X

         5.3       RESET STATISTICS        X             X

         5.3.1     Reset Statistics        X             X

         5.4       LOGOFF                  X             X

         5.4.1     From T to L             X             X

         5.5       RESPONSE TIME           -             X

         5.5.1     Keyboard response time  -         1.3.3 
          …0e…*)…0f…

           *)'Keyboard response time' is executed in PAT and
              PSAT as G.F.C. 5.5.1, but described in G.F.C.
             1.3.3.
















               F̲i̲g̲u̲r̲e̲ ̲3̲.̲2̲-̲2̲ ̲(̲s̲h̲e̲e̲t̲ ̲4̲ ̲o̲f̲ ̲4̲)̲

                     G.F.C. Overview




3.2.1    T̲e̲s̲t̲ ̲G̲r̲o̲u̲p̲ ̲1̲

         Test Group 1 is concerning the start-up and all not
         mode-specific features of the PC-system. See section
         3.3.1.

         The starting point for execution of this Test Group
         is PC hardware and software destined for a site. Extra
         equipment and special documents are stated in Figure
         3.2.1-1.


3.2.2    T̲e̲s̲t̲ ̲G̲r̲o̲u̲p̲ ̲2̲

         Test Group 2 is concerning the Maintenance Mode of
         operation. This is described in section 3.3.2, which
         provides overviews concerning:

         o   Check of modules
         o   Dump of memory
         o   Init to local mode

         The starting point for execution of this Test Group
         is the PC configuration started up to the state where
         a push on the ATTN-button brings the system into Maintenance
         Mode.

         Extra equipment and special documents are stated in
         Figure 3.2.2-1.


3.2.3    T̲e̲s̲t̲ ̲G̲r̲o̲u̲p̲ ̲3̲

         Test Group 3 is concerning the Local Mode of operation.
         This is described in section 3.3.3, which provides
         overviews concerning:

         o   Logon to operational mode
         o   Maintenance mode return

         The starting point for execution of this Test Group
         is the PC configuration started up to the state where
         a push on the ATTN-button brings the system into Local
         Mode.

         Extra equipment and special documents are started in
         Figure 3.2.3-1.





3.2.4    T̲e̲s̲t̲ ̲G̲r̲o̲u̲p̲ ̲4̲

         Test Group 4 is concerning the Operational Mode. This
         is described in section 3.3.4, which provides overview
         concerning:

         o   Show statistics
         o   Reset statistics
         o   Logoff to local mode
         o   Test mode entrance

         The starting point for execution af this Test Group
         is the PC configuration started up to the state where
         a push on the ATTN-button shows that the system is
         in Operational Mode.

         Extra equipment and special documents are stated in
         Figure 3.2.4-1.

         Actions upon fault-categories is shown in figure 3.2.4-2.

         Test of fault-types is shown in Figure 3.2.4-3


3.2.5    T̲e̲s̲t̲ ̲G̲r̲o̲u̲p̲ ̲5̲

         Test Group 5 is concerning the Test Mode of operation.
         This is described in section 3.3.5, which provides
         overview concerning:

         o   Verify link by Test Messages
         o   Show statistics
         o   Reset statistics
         o   Logoff to local mode

         The starting point for execution of this Test Group
         is the PC configuration brought up to the state where
         a push on the ATTN-button will show that the system
         is in Test Mode.

         Extra equipment and special documents are stated in
         Figure 3.2.5-1.







         G̲.̲F̲.̲C̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲N̲A̲M̲E̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲E̲x̲t̲r̲a̲ ̲E̲q̲u̲i̲p̲m̲.̲/̲S̲p̲e̲c̲.̲D̲o̲c̲.̲


         1.1.1       H/W CONFIGURATION   SITE INVENTORY CHECKLIST
                          - ,, -         SITE INVENTORY LIST
                                         REF. 27 and 23

         1.1.2       MAINTENANCE VDU     CSA PRODUCT SPECIFIC-
                                         ATION REF. 25


         1.2.1       V28 L               CAMPS DSMT TEST
                                         (V.28 L/L ADAPTER)
                                         REF. 24

         1.2.2       MIL-STD-188C        V28 L/L ADAPTER
                                         REF. 26

         1.2.3       IDENTICAL H/W       SITE INVENTORY LIST
                     AND S/W             REF. 23

         1.2.4       POWER INPUT         CAMPS DSMT TEST
                                         (POWER INPUT)
                                         REF. 24

         1.2.5       EPROM               SDS (para 3.1.3)

         1.3.1       MODES OF OPERATION  EQUIPMENT HANDBOOK
                                         REF. 20

         1.3.2       PU INITIALIZATION   STOPWATCH

         1.3.3       KEYBOARDS OPERATION
                     RESPONSE TIME       STOPWATCH















                      F̲i̲g̲u̲r̲e̲ ̲3̲.̲2̲.̲1̲-̲1̲

          Extra equipment and special documents
                    for Test Group 1.


         G̲.̲F̲.̲C̲.̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲N̲A̲M̲E̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲E̲x̲t̲r̲a̲ ̲E̲q̲u̲i̲p̲m̲.̲/̲S̲p̲e̲c̲.̲D̲o̲c̲.̲
         ̲


         2.1.2       MAINTENANCE, CHECK   EXTRA 
                                              ERROM
                                              RAM
                                              LTU
                                          WITH EMBEDDED
                                          FAULTS

         2.2.1       MAINTENANCE, DUMP    CORE MAP


































                      F̲i̲g̲u̲r̲e̲ ̲3̲.̲2̲.̲2̲-̲1̲

          Extra equipment and special documents
                    for Test Group 2.


         G̲.̲F̲.̲C̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲N̲A̲M̲E̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲E̲x̲t̲r̲a̲ ̲E̲q̲u̲i̲p̲m̲.̲/̲S̲p̲e̲c̲.̲D̲o̲c̲.̲


         NONE        NONE                 NONE











































                      F̲i̲g̲u̲r̲e̲ ̲3̲.̲2̲.̲3̲-̲1̲

          Extra equipment and special documents
                    for Test Group 3.


         G̲.̲F̲.̲C̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲N̲A̲M̲E̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲E̲x̲t̲r̲a̲ ̲E̲q̲u̲i̲p̲.̲/̲S̲p̲e̲c̲.̲D̲o̲c̲.̲


         4.5.1       CAMPS/SCARS-CCIS     CCIS-link

         4.5.2       CCIS-CAMPS/SCARS     CAMPS/SCARS-link
                                          PC/AUX/004
                                          REF.28

         4.5.3       BETWEEN CCIS AND     Prestored Testmessages
                     CAMPS/SCARS          on both End-Systems

                               
         4.5.4       TRANSMISSION ERRORS  STOPWATCH

         4.6.1       PC DELAY

         4.6.1       PC THROUGHPUT




























                      F̲i̲g̲u̲r̲e̲ ̲3̲.̲2̲.̲4̲-̲1̲

          Extra equipment and special documents
                    for Test Group 4.


C̲A̲T̲E̲G̲O̲R̲Y̲ ̲A̲C̲T̲I̲O̲N̲S̲

         ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

         Category                       Actions
         ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                             Transactions in both directions
                     are
         Unrecoverable       cancelled. PC close down with an
         
         ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲e̲r̲r̲o̲r̲ ̲m̲e̲s̲s̲a̲g̲e̲ ̲t̲o̲ ̲V̲D̲U̲.̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

         Recoverable         Faulty Transactions is cancelled
         in
         ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲b̲o̲t̲h̲ ̲d̲i̲r̲e̲c̲t̲i̲o̲n̲s̲.̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                             Protocol recovery. Increment of
                     
         Statistics          Error Counter. Retransmission       
                                                                 
                                                                 
                                                                 
                                                                 
                                                                 
                                                                 
                                                                 
                                                                 
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲r̲e̲g̲u̲e̲s̲t̲.̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲
                                                                 ̲



                      F̲i̲g̲u̲r̲e̲ ̲3̲.̲2̲.̲4̲-̲2̲

              Actions upon fault-categories








T̲E̲S̲T̲ ̲O̲F̲ ̲F̲A̲U̲L̲T̲ ̲T̲Y̲P̲E̲S̲



 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                            ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲T̲e̲s̲t̲ ̲ ̲
                     ̲ ̲ ̲ ̲ ̲ ̲
  Category            Type                    Pre-
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲t̲e̲s̲t̲ ̲ ̲ ̲F̲a̲t̲ ̲ ̲P̲A̲T̲
 ̲ ̲P̲S̲A̲T̲
                 1. Link-down                 X      X    X
                X
  Unrecoverable    2. Protocol-failure          X
                 3. Sci-error                 X      X    X
                X
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲4̲.̲ ̲P̲C̲-̲ ̲s̲y̲s̲t̲e̲m̲-̲e̲r̲r̲o̲r̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲X̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                 5. Message control- error    X      X    X
                X
  Recoverable        6. New-Transaction           X      X 
                   X    X
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲7̲.̲ ̲T̲r̲a̲n̲s̲a̲c̲t̲i̲o̲n̲ ̲l̲e̲n̲g̲h̲t̲ ̲e̲r̲r̲o̲r̲ ̲ ̲X̲ ̲ ̲ ̲ ̲ ̲ ̲X̲ ̲ ̲ ̲
 ̲X̲ ̲ ̲ ̲ ̲X̲ ̲

  Statistics                  -                 X
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲



                      F̲i̲g̲u̲r̲e̲ ̲3̲.̲2̲.̲4̲-̲3̲

                   Test of fault-types.



         G̲.̲F̲.̲C̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲N̲A̲M̲E̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲E̲x̲t̲r̲a̲ ̲E̲q̲u̲i̲p̲m̲.̲/̲S̲p̲e̲c̲.̲D̲o̲c̲.̲



         5.1.1           TEST, VERIFY     CCIS-link

         5.1.2               - ,, -       CAMPS/SCARS-link






































                      F̲i̲g̲u̲r̲e̲ ̲3̲.̲2̲.̲5̲-̲1̲

          Extra equipment and special documents
                    for Test Group 5.


                     3̲.̲3̲ ̲ ̲T̲E̲S̲T̲ ̲G̲R̲O̲U̲P̲S̲

         In the following five paragraphs the requirements is
         specified for each of the five testgroups. The underlining
         is for CR administrative use only and no significance
         to requirement statement.



3.3.1    T̲E̲S̲T̲G̲R̲O̲U̲P̲ ̲N̲O̲.̲ ̲1̲ ̲

         This Test Group shall demonstrate the start-up and
         other not mode-specific features of the PC-System.


Req.                                                  VERIF.
N̲o̲ ̲ ̲ ̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲ ̲T̲E̲S̲T̲G̲R̲O̲U̲P̲ ̲N̲O̲.̲ ̲1̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲M̲E̲T̲H̲O̲D̲ ̲ ̲G̲.̲F̲.̲C̲.̲

  S̲R̲S̲ ̲2̲.̲2̲

  One off-line converter will be available at each
  site for back-up purposes. The off-line converter
  may be brought on-line by manual replacement with
  one of the on-line converters. T̲h̲e̲ ̲t̲i̲m̲e̲ ̲t̲o̲ ̲i̲n̲i̲t̲i̲a̲-̲
  l̲i̲z̲e̲ ̲t̲h̲e̲ ̲o̲f̲f̲-̲l̲i̲n̲e̲ ̲c̲o̲n̲v̲e̲r̲t̲e̲r̲ ̲s̲h̲a̲l̲l̲ ̲n̲o̲t̲ ̲e̲x̲c̲e̲e̲d̲
 1                                                    3̲
                                                      ̲m̲i̲n̲.̲
                                                      (Excluding
                                                      the
                                                      time
                                                      for
                                                      converter
                                                      replace-        D 1.3.2
  ment).

  S̲R̲S̲ ̲2̲.̲3̲

  PC to SCARS and CAMPS will use a full
  duplex synchronous electrical level on a medium speed
 2                                                    circuit
                                                      u̲s̲i̲n̲g̲
                                                      ̲C̲C̲I̲T̲T̲
                                                      ̲V̲2̲4̲/̲V̲2̲8̲
                                                      ̲a̲n̲d̲
                                                      ̲N̲A̲T̲O̲
                                                      ̲l̲e̲v̲e̲l̲
                                                      ̲i̲n̲t̲e̲r̲f̲a̲c̲e̲      C 1.2.1
  criteria. For the PC-CCIS interface, the electrical
  level will provide a full d̲u̲p̲l̲e̲x̲ ̲M̲I̲L̲-̲S̲T̲D̲-̲1̲8̲8̲C̲ ̲l̲o̲w̲
 3                                                    l̲e̲v̲e̲l̲
                                                      ̲i̲n̲t̲e̲r̲f̲a̲c̲e̲.      C 1.2.2


  S̲R̲S̲ ̲2̲.̲4̲

  P̲r̲o̲v̲i̲s̲i̲o̲n̲ ̲o̲f̲ ̲t̲h̲r̲e̲e̲ ̲m̲o̲d̲e̲s̲ ̲o̲f̲ ̲o̲p̲e̲r̲a̲t̲i̲o̲n̲:                 
                                                         

  a.  o̲f̲f̲-̲l̲i̲n̲e̲ ̲-̲ ̲t̲e̲s̲t̲/̲m̲a̲i̲n̲t̲e̲n̲a̲n̲c̲e̲
 4                                                    b.
                                                      
                                                      o̲n̲-̲l̲i̲n̲e̲
                                                      ̲t̲e̲s̲t̲
                                                      ̲m̲e̲s̲s̲a̲g̲e̲
                                                      ̲c̲r̲e̲a̲t̲i̲o̲n̲/̲r̲e̲c̲e̲p̲t̲i̲o̲n̲  C 1.3.1
  c.  o̲p̲e̲r̲a̲t̲i̲o̲n̲





Req.                                                  VERIF.
N̲o̲ ̲ ̲ ̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲ ̲T̲E̲S̲T̲G̲R̲O̲U̲P̲ ̲N̲O̲.̲ ̲1̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲M̲E̲T̲H̲O̲D̲ ̲ ̲G̲.̲F̲.̲C̲.̲

  S̲R̲S̲ ̲2̲.̲7̲

 5   The protocol converter shall n̲o̲t̲ ̲d̲i̲s̲t̲u̲r̲b̲ the
  end-to-end r̲e̲q̲u̲i̲r̲e̲m̲e̲n̲t̲s̲ ̲f̲o̲r̲ ̲m̲e̲s̲s̲a̲g̲e̲ ̲a̲c̲c̲o̲u̲n̲t̲a̲-̲          A    
                                                              
                                                              -
  b̲i̲l̲i̲t̲y̲, and security, irrespective of the type
  of format employed for the respective links.


  S̲R̲S̲ ̲2̲.̲8̲

 6   e) ̲P̲r̲o̲v̲i̲d̲e̲ ̲s̲e̲c̲u̲r̲i̲t̲y̲ ̲b̲y̲ physical, electrical and     A    
                                                              
                                                              -
     software means.

 7   f)                                               Each
                                                      converter
                                                      shall
                                                      have
                                                      i̲d̲e̲n̲t̲i̲c̲a̲l̲
                                                      ̲H̲/̲W̲
                                                      ̲a̲n̲d̲
     S̲/̲W̲ control facilities.                             C    1.2.3


  S̲R̲S̲ ̲2̲.̲9̲

 8   a)                                               T̲h̲e̲
                                                      ̲d̲e̲s̲i̲g̲n̲
                                                      ̲o̲f̲
                                                      ̲e̲a̲c̲h̲
                                                      ̲c̲o̲n̲v̲e̲r̲t̲e̲r̲
                                                      ̲i̲n̲s̲t̲a̲l̲l̲e̲d̲
                                                      ̲s̲h̲a̲l̲l̲          
     p̲r̲e̲v̲e̲n̲t̲ ̲i̲l̲l̲e̲g̲a̲l̲ ̲a̲c̲c̲e̲s̲s̲,̲ ̲c̲o̲r̲r̲u̲p̲t̲i̲o̲n̲ ̲a̲n̲d̲ ̲c̲o̲m̲-̲      
                                                         A    
                                                              
                                                              -
     p̲r̲o̲m̲i̲s̲e̲ ̲o̲f̲ ̲t̲h̲e̲ ̲d̲a̲t̲a̲ ̲i̲n̲ ̲t̲r̲a̲n̲s̲i̲t̲ ̲i̲n̲ ̲t̲h̲e̲ ̲c̲o̲n̲v̲e̲r̲-̲
     t̲e̲r̲ ̲a̲n̲d̲ ̲d̲a̲t̲a̲ ̲i̲n̲ ̲t̲h̲e̲ ̲i̲n̲t̲e̲r̲c̲o̲n̲n̲e̲c̲t̲e̲d̲ ̲s̲y̲s̲t̲e̲m̲s̲.̲

 9   b)                                               The
                                                      contractor
                                                      shall
                                                      provide
                                                      H̲/̲W̲
                                                      ̲a̲n̲d̲
                                                      ̲S̲/̲W̲
                                                      which
                                                              
     satisfies ACE Directive 70-1 for t̲r̲a̲n̲s̲m̲i̲t̲t̲i̲n̲g̲       A    
                                                              
                                                              -
     a̲n̲d̲ ̲p̲r̲o̲c̲e̲s̲s̲i̲n̲g̲ ̲c̲l̲a̲s̲s̲i̲f̲i̲e̲d̲ ̲i̲n̲f̲o̲r̲m̲a̲t̲i̲o̲n̲.

  S̲R̲S̲ ̲2̲.̲1̲1̲

10   a)                                               A̲
                                                      ̲m̲a̲i̲n̲t̲e̲n̲a̲n̲c̲e̲
                                                      ̲V̲D̲U̲
                                                      shall
                                                      be
                                                      provided
                                                      to
                                                      operate
     the O̲N̲-̲l̲i̲n̲e̲ ̲a̲n̲d̲ ̲O̲F̲F̲-̲l̲i̲n̲e̲ ̲t̲e̲s̲t̲ ̲a̲n̲d̲/̲o̲r̲                C    1.3.1
     m̲a̲i̲n̲t̲e̲n̲a̲n̲c̲e̲ modes as well as to provide an 
     I/O device for operator actions required
     during system initialization. The m̲a̲i̲n̲t̲e̲n̲a̲n̲c̲e̲
11                                                    V̲D̲U̲
                                                      shall
                                                      be
                                                      connected
                                                      to
                                                      the
                                                      converters
                                                              C      1.1.2
     using a f̲i̲b̲e̲r̲o̲p̲t̲i̲c̲ ̲c̲o̲n̲n̲e̲c̲t̲i̲o̲n̲.


  S̲R̲S̲ ̲3̲.̲1̲.̲1̲

12   The e̲q̲u̲i̲p̲m̲e̲n̲t̲ ̲t̲o̲ ̲b̲e̲ ̲p̲r̲o̲v̲i̲d̲e̲d̲ ̲i̲s̲ ̲s̲p̲e̲c̲i̲f̲i̲e̲d̲ ̲i̲n̲ ̲       B    1.1.1
  a̲p̲p̲e̲n̲d̲i̲x̲ ̲E̲ to this contract specification.





Req.                                                  VERIF.
N̲o̲ ̲ ̲ ̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲ ̲T̲E̲S̲T̲G̲R̲O̲U̲P̲ ̲N̲O̲.̲ ̲1̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲M̲E̲T̲H̲O̲D̲ ̲ ̲G̲.̲F̲.̲C̲.̲

  S̲R̲S̲ ̲3̲.̲1̲.̲2̲

  I̲n̲t̲e̲g̲r̲a̲t̲i̲o̲n̲ ̲o̲f̲ ̲S̲H̲A̲P̲E̲ ̲S̲u̲p̲p̲l̲i̲e̲d̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲

  The equipment to be provided by the contractor shall
  be used in conjunction with the following SHAPE 
  furnished equipment facilities:

13   a)                                               P̲o̲w̲e̲r̲,
                                                      operating
                                                      environment     B 1.2.4
  b) Signal cables, including one reserve per 
     connection, to CAMPS, SCARS and CCIS
     terminated at the converter installation. CR
     will supply and mount c̲o̲n̲n̲e̲c̲t̲o̲r̲s̲ at PC end,
     and test the connections.

  S̲R̲S̲ ̲3̲.̲2̲.̲1̲

  c) C̲o̲n̲v̲e̲r̲t̲e̲r̲ ̲-̲ ̲m̲a̲i̲n̲t̲e̲n̲a̲n̲c̲e̲ ̲V̲D̲U̲

14                                                    A̲s̲y̲n̲c̲h̲r̲o̲n̲o̲u̲s̲
                                                      ̲s̲t̲a̲n̲d̲a̲r̲d̲
                                                      ̲t̲e̲l̲e̲t̲y̲p̲e̲
                                                      ̲c̲o̲m̲p̲a̲t̲i̲b̲l̲e̲
                                                      ̲i̲n̲t̲e̲r̲-̲
     f̲a̲c̲e̲ shall be used. The physical connection is      C    1.1.2
     in form of a f̲i̲b̲e̲r̲ ̲o̲p̲t̲i̲c̲ ̲c̲a̲b̲l̲e̲.


  S̲R̲S̲ ̲3̲.̲3̲.̲7̲

  A̲l̲p̲h̲a̲b̲e̲t̲

15   The a̲l̲p̲h̲a̲b̲e̲t̲ ̲i̲s̲ ̲t̲h̲e̲ ̲N̲A̲T̲O̲ ̲7̲ ̲b̲i̲t̲ ̲c̲o̲d̲e̲ as specified
     in
  the CAMPS/SCARS/CCIS Intersystem specification,        A
  page 3-A-4-2. Parity bits shall be selectable to 
  odd, even or nil on all channels.

  S̲R̲S̲ ̲3̲.̲4̲.̲1̲.̲2̲

16   b)                                               The
                                                      r̲e̲s̲p̲o̲n̲s̲e̲
                                                      ̲t̲i̲m̲e̲
                                                      for
                                                      the
                                                      keyboard
                                                      operation       D l.3.3
     will be w̲i̲t̲h̲i̲n̲ ̲5̲ ̲s̲e̲c̲.̲ ̲o̲n̲ ̲9̲5̲%̲ ̲o̲f̲ ̲c̲a̲s̲e̲s̲.

17   c)                                               All
                                                      commands
                                                      to
                                                      the
                                                      system
                                                      shall
                                                      be
                                                      given
                                                              A
     through a c̲o̲m̲m̲a̲n̲d̲ ̲l̲a̲n̲g̲u̲a̲g̲e̲.





Req.                                                  VERIF.
N̲o̲ ̲ ̲ ̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲ ̲T̲E̲S̲T̲G̲R̲O̲U̲P̲ ̲N̲O̲.̲ ̲1̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲M̲E̲T̲H̲O̲D̲ ̲ ̲G̲.̲F̲.̲C̲.̲


  S̲R̲S̲ ̲3̲.̲4̲.̲3̲

18   a)                                               A̲l̲l̲
                                                      ̲p̲r̲o̲g̲r̲a̲m̲s̲
                                                      ̲a̲r̲e̲
                                                      ̲s̲t̲o̲r̲e̲d̲
                                                      ̲i̲n̲
                                                      ̲E̲P̲R̲O̲M̲S̲.
                                                      No
                                                      loading        C 1.2.5
     from external sources are therefore required.

19   b)                                               I̲n̲i̲t̲i̲a̲l̲i̲z̲a̲t̲i̲o̲n̲
                                                      ̲t̲i̲m̲e̲
                                                      ̲s̲h̲a̲l̲l̲
                                                      ̲n̲o̲t̲
                                                      ̲e̲x̲c̲e̲e̲d̲
                                                      ̲3̲
                                                      ̲m̲i̲n̲.
                                                              D      1.3.2
     including operator actions but excluding time
     used for eventual manual replacement of on-line
     converter by the redundant off-line converter 
     and patching VDU connection to the converter in
     question.

  S̲R̲S̲ ̲3̲.̲4̲.̲5̲

20   a)                                               Reconfiguration
                                                      shall
                                                      be
                                                      performed
                                                      by
                                                      manual         D 1.3.2
     replacement of one on-line converter with the
     redundant off-line converter, or part hereof,
     followed by the initialization procedure described
     under 3.4.3.





3.3.2    T̲E̲S̲T̲ ̲G̲R̲O̲U̲P̲ ̲N̲O̲.̲ ̲2̲

         The purpose of this Test Group is to provide an examination
         and a demonstration of the Maintenance 
         Mode capabilities. The fulfilment of the following
         requirements is investigated.



Req.                                                  VERIF.
N̲o̲ ̲ ̲ ̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲ ̲T̲E̲S̲T̲G̲R̲O̲U̲P̲ ̲N̲O̲.̲ ̲2̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲M̲E̲T̲H̲O̲D̲ ̲ ̲G̲.̲F̲.̲C̲.̲

  S̲R̲S̲ ̲2̲.̲4̲

1 G̲u̲i̲d̲a̲n̲c̲e̲ ̲o̲f̲ ̲m̲a̲i̲n̲t̲e̲n̲a̲n̲c̲e̲ ̲a̲c̲t̲i̲v̲i̲t̲y̲ ̲i̲n̲ ̲m̲a̲i̲n̲t̲e̲n̲a̲n̲c̲e̲        D    2.1.1
  m̲o̲d̲e̲


  S̲R̲S̲ ̲3̲.̲4̲.̲1̲.̲2̲

  The maintenance VDU provides an interactive
  machine interface in:

2 -  O̲f̲f̲-̲l̲i̲n̲e̲ ̲m̲a̲i̲n̲t̲e̲n̲a̲n̲c̲e̲ ̲m̲o̲d̲e̲; interactive              D    2.1.1
     isolaton of the faulty converter module.


  S̲R̲S̲ ̲3̲.̲4̲.̲2̲

3 b) Fault finding shall be performed through this 
     VDU. The Maintenance Engineer shall have
     facilities through commands to start software       D    2.1.1
     p̲r̲o̲g̲r̲a̲m̲s̲ ̲t̲o̲ ̲t̲e̲s̲t̲ ̲t̲h̲e̲ ̲i̲n̲d̲i̲v̲i̲d̲u̲a̲l̲ ̲r̲e̲p̲l̲a̲c̲e̲a̲b̲l̲e̲
     m̲o̲d̲u̲l̲e̲ and pinpoint faulty modules.


  S̲R̲S̲ ̲3̲.̲4̲.̲3̲

  a) System initialization shall be performed as
     follows:

4 -  Power-on and c̲h̲e̲c̲k̲s̲u̲m̲m̲i̲n̲g̲ ̲o̲f̲ the program in         D    2.1.1
     E̲P̲R̲O̲M̲.





Req.                                                  VERIF.
N̲o̲ ̲ ̲ ̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲ ̲T̲E̲S̲T̲G̲R̲O̲U̲P̲ ̲N̲O̲.̲ ̲2̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲M̲E̲T̲H̲O̲D̲ ̲ ̲G̲.̲F̲.̲C̲.̲

  S̲R̲S̲ ̲3̲.̲4̲.̲6̲

5 b) The operation staff shall have the facility to      D    2.1.1
     execute maintenance programs on the converter
     equipment in o̲f̲f̲-̲l̲i̲n̲e̲ ̲m̲a̲i̲n̲t̲e̲n̲a̲n̲c̲e̲ ̲m̲o̲d̲e̲. The 
     Execution of the programs shall be initiated from
     the maintenance VDU.

6 c) Maintenance and d̲i̲a̲g̲n̲o̲s̲t̲i̲c̲ ̲o̲n̲ ̲o̲n̲e̲ ̲c̲o̲n̲v̲e̲r̲t̲e̲r̲ ̲        B    2.1.1
     s̲h̲a̲l̲l̲ ̲n̲o̲t̲ ̲e̲f̲f̲e̲c̲t̲ ̲t̲h̲e̲ ̲f̲u̲n̲c̲t̲i̲o̲n̲i̲n̲g̲ ̲o̲f̲ ̲t̲h̲e̲ ̲o̲t̲h̲e̲r̲
     c̲o̲n̲v̲e̲r̲t̲e̲r̲(̲s̲)̲.

7 d) The m̲a̲i̲n̲t̲e̲n̲a̲n̲c̲e̲ ̲p̲r̲o̲g̲r̲a̲m̲s̲ shall aim to l̲o̲c̲a̲t̲e̲        D    2.1.1
     f̲a̲u̲l̲t̲s̲ to the smallest replaceable sub-assembly
     (CR80 module).

8 f) The converter shall i̲n̲c̲l̲u̲d̲e̲ ̲a̲ ̲c̲h̲e̲c̲k̲s̲u̲m̲ ̲f̲a̲c̲i̲l̲i̲t̲y̲     D    2.3.1
     for validation of the program code at full 
     package level. The checksum shall be displayed 
     on the VDU and also compared with a prestored
     value.



3.3.3    T̲E̲S̲T̲G̲R̲O̲U̲P̲ ̲N̲O̲.̲ ̲3̲

         This Test Group shall demonstrate the Local Mode activities.

Req.                                                  VERIF.
N̲o̲ ̲ ̲ ̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲ ̲T̲E̲S̲T̲G̲R̲O̲U̲P̲ ̲N̲O̲.̲ ̲3̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲M̲E̲T̲H̲O̲D̲ ̲ ̲G̲.̲F̲.̲C̲.̲

  S̲R̲S̲ ̲2̲.̲3̲

 1                                                    T̲h̲e̲
                                                      ̲c̲o̲n̲v̲e̲r̲t̲e̲r̲
                                                      ̲w̲i̲l̲l̲
                                                      ̲b̲e̲
                                                      ̲d̲e̲s̲i̲g̲n̲e̲d̲
                                                      ̲i̲n̲
                                                      ̲s̲u̲c̲h̲
                                                      ̲a̲
                                                      ̲w̲a̲y̲
                                                      ̲t̲h̲a̲t̲
                                                      ̲
  i̲t̲ ̲c̲a̲n̲ ̲b̲e̲ ̲u̲s̲e̲d̲ ̲f̲o̲r̲ ̲a̲l̲l̲ ̲s̲i̲g̲n̲a̲l̲ ̲l̲i̲n̲e̲s̲ ̲i̲r̲r̲e̲s̲p̲e̲c̲t̲i̲v̲e̲ ̲
  o̲f̲ ̲t̲h̲e̲ ̲s̲p̲e̲c̲i̲f̲i̲c̲s̲ ̲o̲f̲ ̲t̲h̲e̲ ̲s̲y̲s̲t̲e̲m̲s̲ ̲i̲n̲t̲e̲r̲c̲o̲n̲n̲e̲c̲t̲e̲d̲.̲ ̲
  (̲C̲A̲M̲P̲S̲ ̲o̲r̲ ̲S̲C̲A̲R̲S̲)̲.̲                                      D    3.1.1


  S̲R̲S̲ ̲3̲.̲3̲.̲1̲

 2                                                    f)
                                                      The
                                                      l̲o̲g̲-̲o̲n̲
                                                      ̲s̲e̲q̲u̲e̲n̲c̲e̲
                                                      to
                                                      be
                                                      exchanged
                                                      with
                                                      CCIS
     shall be performed v̲i̲a̲ ̲t̲h̲e̲ ̲M̲a̲i̲n̲t̲e̲n̲a̲n̲c̲e̲ ̲V̲D̲U̲.̲         D    3.1.1

  S̲R̲S̲ ̲3̲.̲3̲.̲3̲


 3                                                    The
                                                      l̲o̲g̲-̲o̲n̲
                                                      ̲p̲r̲o̲c̲e̲d̲u̲r̲e̲
                                                      to
                                                      CCIS
                                                      shall
                                                      d̲i̲s̲t̲i̲n̲g̲u̲i̲s̲h̲     D 3.1.1
  b̲e̲t̲w̲e̲e̲n̲ ̲"̲C̲A̲M̲P̲S̲"̲ ̲a̲n̲d̲ ̲"̲S̲C̲A̲R̲S̲"̲


  S̲P̲S̲ ̲3̲.̲4̲.̲3̲.̲ ̲a̲)̲

 4                                                    -
                                                      
                                                      
                                                      Initiate
                                                      log-on
                                                      to
                                                      CCIS.          D 3.1.1

 5                                                    -
                                                      
                                                      
                                                      Open
                                                      channel
                                                      to
                                                      CAMPS/SCARS.    D 3.1.1


3.3.4    T̲E̲S̲T̲G̲R̲O̲U̲P̲ ̲N̲O̲.̲ ̲4̲

         In the Operational Mode Test Group, the following requirements
         applies.

Req.                                                  VERIF.
N̲o̲ ̲ ̲ ̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲ ̲T̲E̲S̲T̲G̲R̲O̲U̲P̲ ̲N̲O̲.̲ ̲4̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲M̲E̲T̲H̲O̲D̲ ̲ ̲G̲.̲F̲.̲C̲.̲

  S̲R̲S̲ ̲2̲.̲7̲

                                                      Messages
                                                      and
                                                      data
                                                      routed
                                                      on
                                                      CAMPS/SCARS
                                                      -
                                                      CCIS
  medium speed connections are to be transmitted
                                                      and
                                                      handled
                                                      in
                                                      accordance
                                                      with
                                                      t̲h̲e̲
                                                      ̲s̲p̲e̲c̲i̲f̲i̲c̲a̲t̲i̲o̲n̲s̲
 1                                                    f̲o̲r̲
                                                      ̲t̲h̲e̲
                                                      ̲C̲A̲M̲P̲S̲/̲S̲C̲A̲R̲S̲
                                                      ̲-̲
                                                      ̲P̲C̲
                                                      ̲l̲i̲n̲k̲
                                                      ̲a̲n̲d̲
                                                      ̲w̲i̲t̲h̲
                                                      ̲t̲h̲e̲
                                                      ̲s̲p̲e̲c̲i̲-̲         A
 2                                                    f̲i̲c̲a̲t̲i̲o̲n̲s̲
                                                      ̲f̲o̲r̲
                                                      ̲t̲h̲e̲
                                                      ̲P̲C̲
                                                      ̲-̲
                                                      ̲C̲C̲I̲S̲
                                                      ̲l̲i̲n̲k̲.̲
                                                      
                                                      
                                                              A


  S̲R̲S̲ ̲2̲.̲8̲

  The converter shall contain the following control
  facilities:

  a) Be transparent for the data that passes through
 3                                                    the
                                                      converter,
                                                      i.e.
                                                      i̲t̲
                                                      ̲s̲h̲a̲l̲l̲
                                                      ̲n̲o̲t̲
                                                      ̲m̲o̲d̲i̲f̲y̲
                                                      ̲t̲h̲e̲
                                                      ̲m̲e̲s̲s̲a̲g̲e̲        D 4.5.1
  i̲n̲f̲o̲r̲m̲a̲t̲i̲o̲n̲ ̲c̲o̲n̲t̲e̲n̲t̲.̲                                        4.5.2

 4                                                    b)
                                                      A̲f̲t̲e̲r̲
                                                      ̲a̲n̲y̲
                                                      ̲f̲a̲i̲l̲u̲r̲e̲
                                                      ̲i̲t̲
                                                      ̲s̲h̲a̲l̲l̲
                                                      ̲n̲o̲t̲
                                                      by
                                                      means
                                                      of
                                                      ge-
  nerated acknowledgement and other signals provoke
  accidental loss of transfer, i.e. p̲r̲o̲v̲o̲k̲e̲ ̲t̲h̲e̲ ̲t̲w̲o̲      D    4.5.4
  c̲o̲n̲n̲e̲c̲t̲e̲d̲ ̲s̲y̲s̲t̲e̲m̲s̲ ̲t̲o̲ ̲b̲e̲l̲i̲e̲v̲e̲ ̲t̲h̲a̲t̲ ̲d̲a̲t̲a̲ ̲h̲a̲v̲e̲ ̲b̲e̲e̲n̲
  t̲r̲a̲n̲s̲f̲e̲r̲r̲e̲d̲ ̲c̲o̲r̲r̲e̲c̲t̲l̲y̲.̲

 5                                                    c)
                                                      N̲o̲t̲
                                                      ̲p̲e̲r̲m̲i̲t̲
                                                      ̲d̲e̲a̲d̲
                                                      ̲l̲o̲c̲k̲,̲
                                                      i.e.
                                                      where
                                                      the
                                                      converter
  is in a permanent blocked state waiting for a          A
  message which will never arrive.

 6                                                    d)
                                                      N̲o̲t̲
                                                      ̲p̲e̲r̲m̲i̲t̲
                                                      ̲c̲r̲i̲t̲i̲c̲a̲l̲
                                                      ̲b̲l̲o̲c̲k̲i̲n̲g̲        A


  S̲R̲S̲ ̲2̲.̲1̲1̲

 7                                                    The
                                                      c̲o̲n̲v̲e̲r̲t̲e̲r̲
                                                      ̲s̲h̲a̲l̲l̲
                                                      ̲b̲e̲
                                                      ̲a̲b̲l̲e̲
                                                      ̲t̲o̲
                                                      ̲w̲o̲r̲k̲
                                                      ̲w̲i̲t̲h̲o̲u̲t̲
                                                      ̲t̲h̲e̲            A
  m̲a̲i̲n̲t̲e̲n̲a̲n̲c̲e̲ ̲V̲D̲U̲:




Req.                                                  VERIF.
N̲o̲ ̲ ̲ ̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲ ̲T̲E̲S̲T̲G̲R̲O̲U̲P̲ ̲N̲O̲.̲ ̲4̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲M̲E̲T̲H̲O̲D̲ ̲ ̲G̲.̲F̲.̲C̲.̲

  S̲R̲S̲ ̲3̲.̲2̲.̲1̲

 8                                                    The
                                                      converter
                                                      shall
                                                      o̲p̲e̲r̲a̲t̲e̲
                                                      ̲r̲e̲g̲a̲r̲d̲l̲e̲s̲s̲
                                                      ̲o̲f̲
                                                      ̲a̲n̲y̲
  d̲i̲f̲f̲e̲r̲e̲n̲c̲e̲ ̲i̲n̲ ̲b̲a̲u̲d̲ ̲r̲a̲t̲e̲s̲ ̲s̲e̲t̲ ̲u̲p̲ ̲b̲e̲t̲w̲e̲e̲n̲ ̲t̲h̲e̲            D    4.5.3
  c̲o̲n̲v̲e̲r̲t̲e̲r̲ ̲a̲n̲d̲ ̲i̲t̲s̲ ̲c̲o̲n̲n̲e̲c̲t̲e̲d̲ ̲s̲y̲s̲t̲e̲m̲s̲.̲

  a) L̲i̲n̲k̲ ̲C̲A̲M̲P̲S̲/̲S̲C̲A̲R̲S̲ ̲t̲o̲ ̲c̲o̲n̲v̲e̲r̲t̲e̲r̲ ̲a̲t̲ ̲t̲h̲e̲ ̲c̲o̲n̲-̲
  v̲e̲r̲t̲e̲r̲ ̲s̲i̲d̲e̲.̲

  S̲R̲S̲ ̲3̲.̲2̲.̲2̲

 9                                                    a)
                                                      The
                                                      CAMPS/SCARS
                                                      -
                                                      converter
                                                      link
                                                      shall
                                                      operate
     with synchronous transmission at rates of 2400,     D    4.5.3
     4800 and 9600 bps (selectable).
  b) The CCIS to converter link shall operate with
     synchronous transmission at rates of 2400, 4800,    D    4.5.3
     9600 bps (selectable).

10                                                    H̲a̲l̲f̲
                                                      ̲a̲n̲d̲
                                                      ̲f̲u̲l̲l̲
                                                      ̲d̲u̲p̲l̲e̲x̲
                                                      modes
                                                      of
                                                      operation
                                                      shall
  be implemented in the CCIS - converter links at        A
  the electrical level. Half duplex mode shall
  be implemented working to the Remote Compu-
  ter protocol in CCIS.

  S̲R̲S̲ ̲3̲.̲3̲.̲1̲

  a) Transactions exchanged between systems to
  be passed through the converter equipment              A
11                                                    shall
                                                      be
                                                      in
                                                      E̲1̲
                                                      ̲f̲o̲r̲m̲a̲t̲
                                                      ̲a̲s̲
                                                      ̲s̲p̲e̲c̲i̲f̲i̲e̲d̲
                                                      ̲i̲n̲
                                                      ̲t̲h̲e̲
  S̲S̲.̲ These transactions will be embedded with-
  in the level 3 and 2 protocols as defined
  in SS document for the CAMPS/SCARS - con-
  verter link and, within the DINDAC and RCI
  protocols for the converter - CCIS link.

  b) The converter shall p̲a̲s̲s̲ ̲o̲n̲ ̲t̲h̲e̲ ̲f̲u̲l̲l̲ ̲E̲1̲
  f̲o̲r̲m̲a̲t̲ ̲(̲h̲e̲a̲d̲e̲r̲ ̲a̲n̲d̲ ̲t̲e̲x̲t̲)̲ ̲u̲n̲m̲o̲d̲i̲f̲i̲e̲d̲,̲ i.e. the
12                                                    converter
                                                      is
                                                      fully
                                                      transparent
                                                      with
                                                      respect        D 4.5.1
  to the transaction. There shall be a cha-
  racter by character correspondance between                  4.5.2
  the user text received and the user text
  transmitted by the converter. The user text
  is the portion of the data field of frames
  which is useful for the user.




Req.                                                  VERIF.
N̲o̲ ̲ ̲ ̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲ ̲T̲E̲S̲T̲G̲R̲O̲U̲P̲ ̲N̲O̲.̲ ̲4̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲M̲E̲T̲H̲O̲D̲ ̲ ̲G̲.̲F̲.̲C̲.̲

  S̲R̲S̲ ̲3̲.̲3̲.̲1̲

  c) All transaction types that pass through the
     converter are defined in the SCARS/CAMPS/CCIS
     Intersystem Specification, i.e.:


  -  Messages in E1 format (̲n̲a̲r̲r̲a̲t̲i̲v̲e̲,̲ ̲D̲A̲T̲A̲ ̲a̲n̲d̲
     D̲U̲P̲)
  -  V̲D̲U̲ ̲D̲i̲s̲p̲l̲a̲y̲s̲ ̲i̲n̲ ̲E̲1̲ ̲f̲o̲r̲m̲a̲t̲
13   -                                                T̲e̲r̲m̲i̲n̲a̲l̲-̲t̲o̲-̲t̲e̲r̲m̲i̲n̲a̲l̲
                                                      ̲c̲o̲m̲m̲e̲n̲t̲s̲
                                                      ̲i̲n̲
                                                      ̲E̲1̲
                                                      ̲f̲o̲r̲m̲a̲t̲         D 4.5.1
  -  A̲C̲P̲ ̲1̲2̲7̲ ̲t̲y̲p̲e̲ ̲s̲e̲r̲v̲i̲c̲e̲ ̲m̲e̲s̲s̲a̲g̲e̲s̲ ̲i̲n̲ ̲E̲1̲ ̲f̲o̲r̲m̲a̲t̲               4.5.2
  -  T̲r̲a̲n̲s̲a̲c̲t̲i̲o̲n̲ ̲a̲c̲k̲n̲o̲w̲l̲e̲d̲g̲e̲m̲e̲n̲t̲s̲
  -  F̲i̲n̲a̲l̲ ̲n̲u̲m̲b̲e̲r̲ ̲s̲e̲r̲i̲e̲s̲ ̲i̲n̲ ̲E̲1̲ ̲f̲o̲r̲m̲a̲t̲
  -  C̲h̲a̲n̲n̲e̲l̲ ̲c̲h̲e̲c̲k̲ ̲m̲e̲s̲s̲a̲g̲e̲s̲ ̲i̲n̲ ̲E̲1̲ ̲f̲o̲r̲m̲a̲t̲


  The same DINDAC segment header f̲i̲e̲l̲d̲ ̲H̲D̲R̲T̲Y̲P̲
14   shall contain the same message types as defined     A
  in the SCARS/CAMPS/CCIS Intersystem Specification
  section 6.1.2.5.

15   d) Transactions required for the lower level
  protocols between the converter and its con-           A
  nected system shall be i̲n̲ ̲a̲c̲c̲o̲r̲d̲a̲n̲c̲e̲ ̲w̲i̲t̲h̲ ̲t̲h̲e̲
  r̲e̲s̲p̲e̲c̲t̲i̲v̲e̲ interface p̲r̲o̲t̲o̲c̲o̲l̲s̲.̲

16   g) L̲o̲g̲-̲o̲f̲f̲ ̲m̲e̲s̲s̲a̲g̲e̲ ̲t̲o̲ ̲b̲e̲ ̲t̲r̲a̲n̲s̲m̲i̲t̲t̲e̲d̲ ̲t̲o̲ ̲C̲C̲I̲S̲
  shall be embedded in the converter and may be          D    4.5.4
  e̲n̲v̲o̲k̲e̲d̲ from the maintenance VDU.

  S̲R̲S̲ ̲3̲.̲3̲.̲2̲

  b)D̲a̲t̲a̲ ̲a̲n̲d̲ ̲n̲a̲r̲r̲a̲t̲i̲v̲e̲ ̲m̲e̲s̲s̲a̲g̲e̲ will be l̲i̲m̲i̲t̲e̲d̲
  t̲o̲ ̲1̲2̲0̲0̲0̲ ̲c̲h̲a̲r̲a̲c̲t̲e̲r̲s̲.̲ Display and terminal-to-
17   terminal comment transactions will be limited       D    4.5.4
  to one user page of 20 lines of 80 characters. 
  The protocol converter shall check transaction
  length, trap transactions in excess of that
  length, treat too long transactions to be in
  error and reput errors by means of:

  1.   b̲u̲s̲t̲ ̲m̲e̲s̲s̲a̲g̲e̲ ̲t̲o̲ ̲C̲C̲I̲S̲
  2.   using CAMPS/SCARS standard "̲t̲o̲o̲ ̲l̲o̲n̲g̲
18                                                    
                                                      
                                                      m̲e̲s̲s̲a̲g̲e̲
                                                      ̲p̲r̲o̲c̲e̲d̲u̲r̲e̲s̲"̲     D 4.5.4




Req.                                                  VERIF.
N̲o̲ ̲ ̲ ̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲ ̲T̲E̲S̲T̲G̲R̲O̲U̲P̲ ̲N̲O̲.̲ ̲4̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲M̲E̲T̲H̲O̲D̲ ̲ ̲G̲.̲F̲.̲C̲.̲

  c) All transactions between the two intercon-
  nected systems are a̲c̲k̲n̲o̲w̲l̲e̲d̲g̲e̲d̲ ̲e̲n̲d̲-̲t̲o̲-̲e̲n̲d̲.̲ ̲This
  end-to-end acknowledgement is passed unmodified 
  through the converter. As a consequence the con-
19   verter shall not take responsibility for message    A
  continuity. Transactions shall be handled in
  the converter o̲n̲ ̲a̲ ̲f̲i̲r̲s̲t̲-̲i̲n̲-̲f̲i̲r̲s̲t̲-̲o̲u̲t̲ ̲b̲y̲ ̲p̲r̲e̲-̲
  c̲e̲d̲e̲n̲c̲e̲ ̲basis.

  d) After transmission of the last frame/segment
20   of a message, the protocol converter shall c̲l̲e̲a̲r̲    A
  t̲h̲e̲ ̲b̲u̲f̲f̲e̲r̲ ̲a̲r̲e̲a̲ used for storing the trans-
  actions.


  S̲R̲S̲ ̲3̲.̲3̲.̲4̲

  F̲o̲r̲m̲a̲t̲ ̲C̲o̲n̲t̲r̲o̲l̲

  The converter shall check the consistency of the
  following headerfields.

21   a) A̲l̲l̲ ̲X̲2̲5̲ ̲l̲e̲v̲e̲l̲ ̲2̲ ̲f̲i̲e̲l̲d̲s̲                           A

22   b) The C̲A̲M̲P̲S̲/̲S̲C̲A̲R̲S̲ ̲l̲e̲v̲e̲l̲ ̲3̲ ̲f̲i̲e̲l̲d̲s̲ as follows.       A

     -  I Field Length
     -  Block Sequence Number
     -  Block Type
     -  Message Type
       

23   c) The CCIS DINDAC Header fields as follows:   
                                                         A
     
     -  HDR CDN field (Channel Designator)
     -  HDR CSN field (Channel Sequence Number)
     -  HDR SEG field (Segment Number)
     -  HDR EOT field (End of Transmission)
     -  HDR PRC field (Transaction Precedence)
     -  HDR CLS field (Transaction Classification)
     -  HDR TYP field (Transaction Type)
     -  HDR KEY field (Program Keyword)
     -  HDR SUB field (Transaction Subject Code)
     -  HDR PRN field (Precedence of Next Transaction)
     -  HDR PSN field (Processing Sequence Number)
     -  HDR SIZ field (Length of Segment)





Req.                                                  VERIF.
N̲o̲ ̲ ̲ ̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲ ̲T̲E̲S̲T̲G̲R̲O̲U̲P̲ ̲N̲O̲.̲ ̲4̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲M̲E̲T̲H̲O̲D̲ ̲ ̲G̲.̲F̲.̲C̲.̲

  S̲R̲S̲ ̲3̲.̲3̲.̲5̲

  P̲r̲e̲c̲e̲d̲e̲n̲c̲e̲ ̲a̲n̲d̲ ̲P̲r̲e̲e̲m̲p̲t̲i̲o̲n̲

24   a) The converter shall n̲o̲t̲ ̲p̲r̲e̲e̲m̲p̲t̲ ̲t̲r̲a̲n̲s̲a̲c̲t̲i̲o̲n̲s̲.̲    A

25   b)                                               
                                                      T̲r̲a̲n̲s̲a̲c̲t̲i̲o̲n̲s̲
                                                      ̲p̲r̲e̲e̲m̲p̲t̲e̲d̲
                                                      ̲
                                                      by
                                                      either
                                                      CAMPS,
     SCARS or CCIS s̲h̲a̲l̲l̲ ̲b̲e̲ ̲p̲a̲s̲s̲e̲d̲ ̲u̲n̲m̲o̲d̲i̲f̲i̲e̲d̲
     through the converter, i.e. the converter is
     not required to recognize that a message is         A
     preempted.

26   c) The converter shall a̲d̲j̲u̲s̲t̲ ̲f̲o̲r̲ ̲d̲i̲f̲f̲e̲r̲e̲n̲c̲e̲s̲
  between the precedence parameter in the DINDAC         A
  segment header and the CAMPS/SCARS level 3
  header.


  S̲R̲S̲ ̲3̲.̲3̲.̲6

  P̲e̲r̲f̲o̲r̲m̲a̲n̲c̲e̲ ̲S̲e̲c̲t̲i̲o̲n̲ ̲(̲P̲r̲o̲t̲o̲c̲o̲l̲ ̲C̲o̲n̲v̲e̲r̲t̲e̲r̲)̲

  a)T̲h̲r̲o̲u̲g̲h̲p̲u̲t̲

27   Each converter shall be able to support c̲o̲n̲t̲i̲n̲o̲u̲s̲
  u̲n̲i̲d̲i̲r̲e̲c̲t̲i̲o̲n̲a̲l̲ ̲d̲a̲t̲a̲ ̲t̲r̲a̲n̲s̲f̲e̲r̲ ̲between the connec-       D    4.5.1
  ted systems at up to the f̲u̲l̲l̲ ̲l̲i̲n̲e̲ ̲s̲p̲e̲e̲d̲
  (̲9̲6̲0̲0̲ ̲b̲a̲u̲d̲)̲.̲

  The protocol converter shall be capable of mee-
  ting this requirement concurrently providing
28   full d̲u̲p̲l̲e̲x̲ ̲o̲p̲e̲r̲a̲t̲i̲o̲n̲ ̲b̲e̲t̲w̲e̲e̲n̲ ̲t̲h̲e̲ ̲p̲r̲o̲t̲o̲c̲o̲l̲ ̲c̲o̲n̲-̲     A
  v̲e̲r̲t̲e̲r̲ ̲a̲n̲d̲ ̲C̲A̲M̲P̲S̲ ̲o̲r̲ ̲S̲C̲A̲R̲S̲ ̲a̲n̲d̲ ̲h̲a̲l̲f̲ ̲o̲r̲ ̲f̲u̲l̲l̲
  d̲u̲p̲l̲e̲x̲ ̲o̲p̲e̲r̲a̲t̲i̲o̲n̲ ̲(̲i̲f̲ ̲i̲m̲p̲l̲e̲m̲e̲n̲t̲e̲d̲)̲ ̲t̲o̲ ̲C̲C̲I̲S̲.̲

29   b)T̲h̲e̲ ̲d̲e̲l̲a̲y̲ ̲i̲n̲t̲r̲o̲d̲u̲c̲e̲d̲ ̲b̲y̲ ̲t̲h̲e̲ ̲p̲r̲o̲c̲e̲s̲s̲i̲n̲g̲ ̲o̲f̲
  t̲h̲e̲ ̲c̲o̲n̲v̲e̲r̲t̲e̲r̲ ̲s̲h̲a̲l̲l̲ ̲b̲e̲,̲ ̲i̲n̲ ̲n̲o̲r̲m̲a̲l̲ ̲c̲o̲n̲d̲i̲t̲i̲o̲n̲s̲,̲
  l̲e̲s̲s̲ ̲t̲h̲a̲n̲ ̲o̲n̲e̲ ̲s̲e̲c̲o̲n̲d̲ ̲i̲n̲ ̲b̲o̲t̲h̲ ̲d̲i̲r̲e̲c̲t̲i̲o̲n̲s̲.̲               D    4.6.1
  It will be measured as the time elapsed be-
  tween the last information frame received
  by the converter and the last information 
  frame transmitted by the converter and from
  which is deducted the transmission transfer 
  time, the link turn around time and the time
  that the frames are buffered up in the proto-
  col converter due to unavailability of the
  halfduplex PC-CCIS link.




Req.                                                  VERIF.
N̲o̲ ̲ ̲ ̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲ ̲T̲E̲S̲T̲G̲R̲O̲U̲P̲ ̲N̲O̲.̲ ̲4̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲M̲E̲T̲H̲O̲D̲ ̲ ̲G̲.̲F̲.̲C̲.̲

  S̲R̲S̲ ̲3̲.̲3̲.̲8̲

  T̲r̲a̲f̲f̲i̲c̲ ̲C̲o̲n̲t̲r̲o̲l̲

30   a)If the converter d̲e̲t̲e̲c̲t̲s̲ ̲a̲n̲ ̲u̲n̲r̲e̲c̲o̲v̲e̲r̲a̲b̲l̲e̲
  protocol/transaction f̲a̲u̲l̲t̲ then it shall close         D    4.5.4
  down the links using p̲r̲o̲t̲o̲c̲o̲l̲ ̲f̲u̲n̲c̲t̲i̲o̲n̲s̲ ̲t̲o̲
  b̲e̲ ̲a̲g̲r̲e̲e̲d̲ ̲d̲u̲r̲i̲n̲g̲ ̲t̲h̲e̲ ̲d̲e̲s̲i̲g̲n̲ ̲p̲h̲a̲s̲e̲.̲

31   b)The converter shall make a c̲o̲u̲n̲t̲ ̲o̲f̲ ̲a̲l̲l̲ ̲r̲e̲-̲
  t̲r̲a̲n̲s̲m̲i̲s̲s̲i̲o̲n̲ requests at level 2 of the CAMPS/
  SCARS side at RCI and DINDAC at the CCIS               D    4.1.1
  side. The accumulated values shall be avail-
  able for display and subsequent reset at the
  maintenance VDU.

  S̲R̲S̲ ̲3̲.̲4̲.̲2̲ ̲A̲s̲s̲i̲s̲t̲a̲n̲c̲e̲ ̲f̲a̲c̲i̲l̲i̲t̲i̲e̲s̲ ̲a̲n̲d̲ ̲f̲u̲n̲c̲t̲i̲o̲n̲s̲

32   a)                                               A
                                                      maintenance
                                                      VDU
                                                      shall
                                                      be
                                                      available
                                                      at
                                                      each
                                                              D      4.5.4
  site for connection to a converter through
  manual patching.

  S̲R̲S̲ ̲3̲.̲4̲.̲4̲

  Recovery after two types of failure is defined:

33   a)R̲e̲c̲o̲v̲e̲r̲y̲ ̲a̲f̲t̲e̲r̲ ̲p̲r̲o̲t̲o̲c̲o̲l̲ ̲f̲a̲i̲l̲u̲r̲e̲s̲ where the
  the recovery procedure is defined as part of           A
  the protocol specification, e.g. transmission
  errors.

34   b)R̲e̲c̲o̲v̲e̲r̲y̲ ̲a̲f̲t̲e̲r̲ ̲a̲l̲l̲ ̲o̲t̲h̲e̲r̲ ̲e̲r̲r̲o̲r̲s̲,̲ e.g. link
  failure and dropouts, CAMPS, SCARS or CCIS             A
  failure, power failure, converter failure.

35   In case a) the recovery shall take place in
  accordance with the protocol specification             D    4.1.1
  and m̲o̲d̲i̲f̲y̲ ̲P̲C̲ ̲e̲r̲r̲o̲r̲ counters.

  In case b) the converter shall stop all exe-
36   cution and wait for m̲a̲n̲u̲a̲l̲ ̲f̲a̲u̲l̲t̲ ̲f̲i̲n̲d̲i̲n̲g̲            D    4.5.4
  and initialization of its operation. If
  f̲e̲a̲s̲i̲b̲l̲e̲,̲ the PC shall g̲e̲n̲e̲r̲a̲t̲e̲ ̲a̲ ̲l̲o̲g̲-̲o̲n̲
  p̲r̲o̲c̲e̲d̲u̲r̲e̲ ̲t̲o̲ ̲C̲C̲I̲S̲.̲




Req.                                                  VERIF.
N̲o̲ ̲ ̲ ̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲ ̲T̲E̲S̲T̲G̲R̲O̲U̲P̲ ̲N̲O̲.̲ ̲4̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲M̲E̲T̲H̲O̲D̲ ̲ ̲G̲.̲F̲.̲C̲.̲

  S̲R̲S̲ ̲3̲.̲4̲.̲5̲

37   b)C̲l̲o̲s̲e̲-̲d̲o̲w̲n̲ ̲o̲f̲ ̲a̲ ̲c̲o̲n̲v̲e̲r̲t̲e̲r̲ ̲s̲h̲a̲l̲l̲ ̲b̲e̲ ̲i̲n̲i̲t̲i̲a̲-̲
  t̲e̲d̲ ̲b̲y̲ ̲t̲h̲e̲ ̲s̲u̲p̲e̲r̲v̲i̲s̲o̲r̲y̲ ̲p̲e̲r̲s̲o̲n̲n̲e̲l̲ ̲o̲n̲ ̲e̲a̲c̲h̲ ̲o̲f̲
  t̲h̲e̲ ̲i̲n̲t̲e̲r̲c̲o̲n̲n̲e̲c̲t̲e̲d̲ ̲s̲y̲s̲t̲e̲m̲s̲,̲ or by a log-off            D    4.3.1
  command on the PC maintenance VDU.

  S̲R̲S̲ ̲3̲.̲4̲.̲7̲.̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲r̲e̲q̲u̲i̲r̲e̲m̲e̲n̲t̲s̲

38   a) The converter equipment shall support the
  requirements stated in the FD document (reference      D    4.6.2
  1) for the CAMPS/SCARS - CCIS interconnestions.

  S̲R̲S̲ ̲3̲.̲4̲.̲7̲.̲4̲

  F̲a̲l̲l̲b̲a̲c̲k̲ ̲P̲r̲o̲c̲e̲d̲u̲r̲e̲s̲

  The converter is not required to provide a
39   fallback capability for the computer systems.       D    4.5.4
  When a l̲i̲n̲k̲ with it is b̲r̲o̲k̲e̲n̲, the c̲o̲n̲v̲e̲r̲t̲e̲r̲
  w̲i̲l̲l̲ ̲r̲e̲f̲l̲e̲c̲t̲ ̲t̲h̲a̲t̲ ̲s̲t̲a̲t̲e̲ to the other end of
  the link through use of the proper protocol 
  features.

  S̲R̲S̲ ̲3̲.̲4̲.̲7̲.̲5̲

  I̲n̲f̲o̲r̲m̲a̲t̲i̲o̲n̲ ̲E̲x̲c̲h̲a̲n̲g̲e̲ ̲P̲r̲o̲t̲o̲c̲o̲l̲ ̲a̲n̲d̲ ̲P̲r̲o̲c̲e̲d̲u̲r̲e̲s̲

40   a) The converter shall m̲a̲t̲c̲h̲ ̲t̲h̲e̲ ̲d̲i̲f̲f̲e̲r̲e̲n̲t̲ ̲d̲a̲t̲a̲          4.5.1
  e̲x̲c̲h̲a̲n̲g̲e̲ ̲p̲r̲o̲t̲o̲c̲o̲l̲s̲ implemented in the CAMPS,           D    4.5.2
  SCARS and CCIS systems.

41   b)                                               The
                                                      link
                                                      between
                                                      CAMPS/SCARS
                                                      and
                                                      the
                                                      con-            4.5.1
  verter shall o̲p̲e̲r̲a̲t̲e̲ ̲i̲n̲ ̲a̲c̲c̲o̲r̲d̲a̲n̲c̲e̲ ̲w̲i̲t̲h̲ ̲t̲h̲e̲            D    4.5.2
  SCARS/CAMPS/CCIS Intersystem Specification.

42   c)                                               The
                                                      converter
                                                      -
                                                      CCIS
                                                      link
                                                      s̲h̲a̲l̲l̲
                                                      ̲o̲p̲e̲r̲a̲t̲e̲         4.5.1
  w̲i̲t̲h̲ ̲C̲C̲I̲S̲,̲ ̲R̲C̲I̲ ̲a̲n̲d̲ ̲D̲I̲N̲D̲A̲C̲ ̲p̲r̲o̲t̲o̲c̲o̲l̲s̲.̲                   D    4.5.2

43   d)                                               The
                                                      converter
                                                      shall
                                                      act
                                                      as
                                                      a
                                                      "t̲r̲a̲n̲s̲p̲a̲-̲       D 4.5.1
  r̲e̲n̲t̲ ̲b̲o̲x̲"̲ ̲w̲h̲e̲n̲ ̲t̲h̲e̲r̲e̲ ̲a̲r̲e̲ ̲n̲o̲ ̲p̲r̲o̲t̲o̲c̲o̲l̲/̲t̲r̲a̲n̲s̲-̲                 4.5.2
  a̲c̲t̲i̲o̲n̲ ̲e̲r̲r̲o̲r̲s̲.̲




Req.                                                  VERIF.
N̲o̲ ̲ ̲ ̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲ ̲T̲E̲S̲T̲G̲R̲O̲U̲P̲ ̲N̲O̲.̲ ̲4̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲M̲E̲T̲H̲O̲D̲ ̲ ̲G̲.̲F̲.̲C̲.̲
44   e)                                               When
                                                      protocol/transaction
                                                      errors
                                                      occur   
  the converter will detect the errors and
  r̲e̲a̲c̲t̲ ̲t̲h̲r̲o̲u̲g̲h̲ ̲t̲h̲e̲ ̲d̲e̲f̲i̲n̲e̲d̲ ̲p̲r̲o̲t̲o̲c̲o̲l̲ ̲c̲a̲p̲a̲-̲               D    4.5.4
  b̲i̲l̲i̲t̲i̲e̲s̲.̲

  f) The r̲e̲c̲o̲v̲e̲r̲a̲b̲l̲e̲ ̲p̲r̲o̲t̲o̲c̲o̲l̲/̲transaction 
  errors are:                                         

  -  i̲n̲c̲o̲n̲s̲i̲s̲t̲e̲n̲c̲y̲ in the level 2 or 3 header
     of the CAMPS/SCARS protocol.

  -  i̲n̲c̲o̲n̲s̲i̲s̲t̲e̲n̲c̲y̲ in the RCI protocol or
     DINDAC segment header for the CCIS 
     protocol.

45   g)                                               Unrecoverable
                                                      protocol/transaction
                                                      errors
                                                      can
     by definition not be corrected in the conver-
     ter. These errors shall be t̲r̲a̲p̲p̲e̲d̲ in the con-      D    4.5.4
     verter and the two interconnected systems
     notified through the d̲e̲f̲i̲n̲e̲d̲ ̲p̲r̲o̲t̲o̲c̲o̲l̲ ̲f̲a̲c̲i̲-̲
     l̲i̲t̲i̲e̲s̲.̲


  S̲R̲S̲ ̲3̲.̲4̲.̲7̲.̲6̲

46   S̲e̲r̲v̲i̲c̲e̲ ̲m̲e̲s̲s̲a̲g̲e̲s̲ ̲b̲e̲t̲w̲e̲e̲n̲ ̲t̲h̲e̲ ̲i̲n̲t̲e̲r̲c̲o̲n̲n̲e̲c̲t̲e̲d̲
  s̲y̲s̲t̲e̲m̲s̲ ̲w̲i̲l̲l̲ ̲b̲e̲ ̲p̲a̲s̲s̲e̲d̲ ̲t̲h̲r̲o̲u̲g̲h̲ ̲t̲h̲e̲ ̲c̲o̲n̲v̲e̲r̲t̲e̲r̲                4.5.1
  t̲r̲a̲n̲s̲p̲a̲r̲e̲n̲t̲l̲y̲ ̲l̲i̲k̲e̲ ̲m̲e̲s̲s̲a̲g̲e̲s̲.̲ No special actions        D    4.5.2
  shall be taken by the converter (for definition
  of these service messages, refer to SCARS/CAMPS/ 
  CCIS Intersystem Specification.

  S̲R̲S̲ ̲3̲.̲4̲.̲7̲.̲7̲.̲

47   S̲e̲r̲v̲i̲c̲e̲ ̲m̲e̲s̲s̲a̲g̲e̲s̲ ̲b̲e̲t̲w̲e̲e̲n̲ a system and the con-
  verter shall be exchanged in accordance with
  the respective e̲x̲c̲h̲a̲n̲g̲e̲ ̲p̲r̲o̲t̲o̲c̲o̲l̲s̲ ̲a̲n̲d̲ ̲p̲r̲o̲c̲e̲-̲
  d̲u̲r̲e̲s̲ on the two links of the converter                A





3.3.5    T̲E̲S̲T̲G̲R̲O̲U̲P̲ ̲N̲O̲.̲ ̲5̲

         The Test Group for Test Mode shall fulfil the following
         requirements. 

Req.                                                  VERIF.
N̲o̲ ̲ ̲ ̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲ ̲T̲E̲S̲T̲G̲R̲O̲U̲P̲ ̲N̲O̲:̲ ̲5̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲M̲E̲T̲H̲O̲D̲ ̲ ̲G̲.̲F̲.̲C̲.̲

  S̲R̲S̲ ̲2̲.̲4̲

 1                                                    C̲r̲e̲a̲t̲i̲o̲n̲
                                                      ̲o̲f̲
                                                      ̲a̲
                                                      ̲p̲r̲e̲s̲t̲o̲r̲e̲d̲
                                                      ̲s̲e̲t̲
                                                      ̲o̲f̲
                                                      ̲t̲e̲s̲t̲m̲e̲s̲s̲a̲g̲e̲s̲
                                                      ̲t̲o̲
                                                      ̲b̲e̲
  t̲r̲a̲n̲s̲m̲i̲t̲t̲e̲d̲ ̲t̲o̲ ̲C̲A̲M̲P̲S̲/̲S̲C̲A̲R̲S̲ ̲A̲N̲D̲ ̲C̲C̲I̲S̲.̲                   D    5.1.1

 2                                                    R̲e̲c̲e̲p̲t̲i̲o̲n̲
                                                      ̲o̲f̲
                                                      ̲t̲e̲s̲t̲m̲e̲s̲s̲a̲g̲e̲s̲
                                                      ̲a̲n̲d̲
                                                      ̲c̲o̲m̲p̲a̲r̲i̲s̲o̲n̲
                                                      ̲w̲i̲t̲h̲
                                                      ̲t̲h̲e̲
  a̲b̲o̲v̲e̲ ̲m̲e̲n̲t̲i̲o̲n̲e̲d̲ ̲s̲e̲t̲ ̲o̲f̲ ̲t̲e̲s̲t̲m̲e̲s̲s̲a̲g̲e̲s̲.̲                   D    5.1.1

  S̲R̲S̲ ̲3̲.̲3̲.̲1̲

 3                                                    e)
                                                      For
                                                      use
                                                      during
                                                      test
                                                      mode,
                                                      t̲e̲s̲t̲
                                                      ̲m̲e̲s̲s̲a̲g̲e̲s̲
                                                      ̲s̲h̲a̲l̲l̲
  b̲e̲ ̲e̲m̲b̲e̲d̲d̲e̲d̲ ̲i̲n̲ ̲t̲h̲e̲ ̲c̲o̲n̲v̲e̲r̲t̲e̲r̲ for transmission to       D    5.1.1
  either of the interconnected systems and for
  reception and check.


  S̲R̲S̲ ̲3̲.̲4̲.̲1̲.̲2̲

 4                                                    -
                                                      d̲i̲s̲p̲l̲a̲y̲
                                                      ̲o̲f̲
                                                      ̲a̲c̲c̲u̲m̲u̲l̲a̲t̲e̲d̲
                                                      ̲c̲o̲u̲n̲t̲e̲r̲s̲
                                                      ̲o̲n̲
                                                      ̲a̲n̲
                                                      ̲e̲r̲r̲o̲r̲
    category basis and log-on/log-off.                   D    5.2.1

  - g̲e̲n̲e̲r̲a̲t̲i̲o̲n̲ ̲a̲n̲d̲ ̲t̲r̲a̲n̲s̲m̲i̲s̲s̲i̲o̲n̲ ̲o̲f̲ ̲t̲e̲s̲t̲ ̲m̲e̲s̲s̲a̲g̲e̲s̲,        D    5.1.1
 5                                                    
                                                      
                                                      reception
                                                      and
                                                      validation
                                                      of
                                                      test
                                                      messages
    and display of test results.

  S̲R̲S̲ ̲3̲.̲4̲.̲6̲

 6                                                    The
                                                      converter
                                                      shall
                                                      include
                                                      t̲e̲s̲t̲
                                                      ̲m̲e̲s̲s̲a̲g̲e̲s̲
                                                      for
  test of the links to CAMPS/SCARS and CCIS              D    5.1.1
  i̲n̲ ̲o̲n̲-̲l̲i̲n̲e̲ ̲t̲e̲s̲t̲ ̲m̲o̲d̲e̲.̲


3.4      F̲U̲N̲C̲T̲I̲O̲N̲/̲T̲E̲S̲T̲ ̲R̲E̲L̲A̲T̲I̲O̲N̲S̲H̲I̲P̲

         This section shows the Function/Test Matrix which contains
         the relations between the System Requirements, the
         Test Groups and the Verification Methods. See Figure
         3.4-1.

                   F̲U̲N̲C̲T̲I̲O̲N̲/̲T̲E̲S̲T̲ ̲M̲A̲T̲R̲I̲X̲


 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

        FUNCTION/VERIFICATION METHOD                 T̲E̲S̲T̲
 ̲G̲R̲O̲U̲P̲ ̲N̲O̲.̲   
                                                   1   2
   3   4   5
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

2.    Technical Overview

2.1   System Overview, Location, Purpose

2.2   Connectivity and Mode of Operation         D

2.3   Circuit Usage Flexibility                  C       D

2.4   Facilities and Functions                   C   D           D

2.5   Installation

2.6   Equipment Configuration

2.7   Message and Data Handling

2.8   Control                                    C           D

2.9   Security                                               
                                                             

2.10  Software

2.10.1                                           Software
                                                 Design

2.10.2                                           System Software

2.10.3                                           Application
                                                 Software

2.11  Supervisor and Control Function            C 

2.12  Implementation and Testing
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲


             F̲I̲G̲U̲R̲E̲ ̲3̲.̲4̲-̲1̲  (Sheet 1 of 4)


          F̲U̲N̲C̲T̲I̲O̲N̲/̲T̲E̲S̲T̲ ̲M̲A̲T̲R̲I̲X̲ (continued)

 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

        FUNCTION/VERIFICATION METHOD                 T̲E̲S̲T̲
 ̲G̲R̲O̲U̲P̲ ̲N̲O̲.̲   
                                                   1   2
   3   4   5
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

3.    Technical Requirements

3.1   Equipment to be Provided

3.1.1 General                                    B

3.1.2 Integration of SHAPE Supplied Equipment    B

3.1.3 Performance and Interface Characteris-
      tics of SHAPE Supplied Equipment

3.1.4 Quantities of Equipment to be Supplied
      by SHAPE

3.1.5 Interchange Circuits - 
      Electrical Characteristics

3.1.6 Equipment to be Provided by CR

3.2   Communication Links between Systems

3.2.1 Mode of Operation                          C           D

3.2.2 Baud Rates                                             D

3.3   Transaction Interchange Requirements

3.3.1 Messages, Types and Formats                        D   D
                                                                 D

3.3.2 Transaction Characteristics                            D

3.3.3 Format Definition Parameters                       D



 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲


             F̲I̲G̲U̲R̲E̲ ̲3̲.̲4̲-̲1̲  (Sheet 2 of 4)


          F̲U̲N̲C̲T̲I̲O̲N̲/̲T̲E̲S̲T̲ ̲M̲A̲T̲R̲I̲X̲ (continued)

 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

        FUNCTION/VERIFICATION METHOD                 T̲E̲S̲T̲
 ̲G̲R̲O̲U̲P̲ ̲N̲O̲.̲   
                                                   1   2
   3   4   5
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

3.3.4 Format Control

3.3.5 Precedence and Preemption

3.3.6 Converter Performance Requirements                     D

3.3.7 Alphabet

3.3.8 Traffic Control                                        D

3.4   Converter Requirements

3.4.1 Converter Characteristics

3.4.1.1                                          Configuration      
                                                                    

3.4.1.2                                          Interactive
                                                 Operation   D   D    D

3.4.2 Assistance Facilities and Functions            D

3.4.3 System Initialization                      CD  D   D

3.4.4 Recovery                                               D

3.4.5 Reconfiguration                            D           D

3.4.6 Maintenance Requirements                       BD          D

3.4.7 Interface Characteristics

3.4.7.1                                          General

3.4.7.2                                          Functional
                                                 Requirements         D


 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲


             F̲I̲G̲U̲R̲E̲ ̲3̲.̲4̲-̲1̲  (Sheet 3 of 4)


             F̲U̲N̲C̲T̲I̲O̲N̲/̲T̲E̲S̲T̲ ̲M̲A̲T̲R̲I̲X̲ (continued)

 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

        FUNCTION/VERIFICATION METHOD                 T̲E̲S̲T̲
 ̲G̲R̲O̲U̲P̲ ̲N̲O̲.̲   
                                                   1   2
   3   4   5
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

3.4.7.3                                          Interface
                                                 Security
                                                 Configuration

3.4.7.4                                          Fallback
                                                 Procedures          D

3.4.7.5                                          Information
                                                 Exchange
                                                 Protocol
      and Procedures                                         D

3.4.7.6                                          Service
                                                 Messages
                                                 between
                                                 CAMPS/SCARS         D


























 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲


             F̲I̲G̲U̲R̲E̲ ̲3̲.̲4̲-̲1̲  (Sheet 4 of 4)