DataMuseum.dk

Presents historical artifacts from the history of:

CR80 Wang WCS documentation floppies

This is an automatic "excavation" of a thematic subset of
artifacts from Datamuseum.dk's BitArchive.

See our Wiki for more about CR80 Wang WCS documentation floppies

Excavated with: AutoArchaeologist - Free & Open Source Software.


top - download

⟦9c864b80f⟧ Wang Wps File

    Length: 13901 (0x364d)
    Types: Wang Wps File
    Notes: Spelunked
    Names: »~ORPHAN63.08«

Derivation

└─⟦9a531dff6⟧ Bits:30006257 8" Wang WCS floppy, CR 0157A
    └─ ⟦this⟧ »~ORPHAN63.08« 

WangText



                 
                  
                  
 CHAPTER 8
                            
                            
                            
                            
                            
                            
                            
                            
                            
                            
                            
                            
                            
                            
                            
                            
                            
                            
                            
                            
                            
                            
                            
                            
                            
                            
                            
                            
                            
                            
                            
                            Page
                            #
        DOCUMENT III
      TECHNICAL PROPOSAL
          Apr. 29,
 1982




         LIST OF CONTENTS                               Page

8.       ENVIRONMENTAL CHARACTERISTICS & COMMON ASPECTS   2

8.1      General                                          2

8.2      Climatic Environmental Characteristics           2
8.2.1    Gneral                                           2
8.2.2    Operating Characteristics                        3
8.2.3    Storage and Transport Characteristics            5

8.3      Electrical Environmental Characteristics         6
8.3.1    Static Electricity                               6
8.3.2    Electromagnetic Waves                            6
8.3.3    Interference on Power Feed Lines                 6
8.3.4Overvoltage Protection                               7

8.4      Common Aspect                                    8
8.4.1    Safety                                           8
8.4.2    Human Engineering                                9
8.4.3    Maintenance and Repair                           9
8.4.4    Expandability                                   11
8.4.5    System Life Time                                11
8.4.6    Components                                      12
8.4.7    Testing                                         13
8.4.8    Marking                                         13
8.4.9    Changeabe Marking                               13
8.4.10   Mechanical Dimensions                           14
8.4.11   Power Supplies                                  14…86…1
                                                           
                                                           
                                                           
                                                         …02…  
                                                           
                                                           
                                                           
                                                           
                                                           
                                                           
                                                         …02…  
                                                           
                                                           
                                                           
                                                           
                                                           
                                                           
                                                           
                                                           
                                                           
                                                           
                                                           
                                                         
8.       E̲N̲V̲I̲R̲O̲N̲M̲E̲N̲T̲A̲L̲ ̲C̲H̲A̲R̲A̲C̲T̲E̲R̲I̲S̲T̲I̲C̲S̲ ̲A̲N̲D̲ ̲C̲O̲M̲M̲O̲N̲ ̲A̲S̲P̲E̲C̲T̲S̲


8.1      G̲e̲n̲e̲r̲a̲l̲

         The Christian Rovsing equipment will be designed,manufactured,tested,
         and installed according to the prevailng CR Standards
         and Specifications.

         Unless otherwise stated, the Christian Rovsing equipment
         will furthermore be in accordance with the CCITT recommendations
         specified in the Christian Rovsing Technical Specification
         at the issue applicable at th time of tender.

8.2      C̲l̲i̲m̲a̲t̲i̲c̲ ̲E̲n̲v̲i̲r̲o̲n̲m̲e̲n̲t̲a̲l̲ ̲C̲h̲a̲r̲a̲c̲t̲e̲r̲i̲s̲t̲i̲c̲s̲

8.2.1    G̲e̲n̲e̲r̲a̲l̲

         The equipment is designed and constructed to be used
         in normal office environments or air conditioned computer
         rooms.…86…1          …02…   …02…   …02…   …02…                        
                         
8.2.2    O̲p̲e̲r̲a̲t̲i̲n̲g̲ ̲C̲h̲a̲r̲a̲c̲t̲e̲r̲i̲s̲t̲i̲c̲s̲

         These limits apply to the equipment installed as specified
         and operating or under maintenance in a normal office
         or computer room environment:


         Room Temperature:          15 deg C - 32 deg C

         Temperature Change:        Less than 6 deg C/hour

         Relative Humidity:         20% RH - 80% RH non-con-
                                      densing

         Humidity Change:           Less than 10% RH/hour

         Absolute Humidity:         Less than 22g H…0f…2…0e…O/m…0e…3…0f…            air

         Altitude:                  0-2000m
…02…Sinusodial Vibration:               Accelaration amplitude of
                                                                
                                                                
                                                                
                                                                
                                                                
                                                                
                                                                
                                                                
                                                                
                                                                
                                                                
                                                                
                                                                
                                                                
                                                                
                                                                
                                                                
                                                                
                                                                
                                                                
                                                                
                                                                
                                                                
                                                                
                                                                
                                                                
                                                                
                                                                0.
                                                                g
                                                                limited
                                                                by
                                                                a
                                                                maximum
                                       displacement amplitude
 of
                                       0.02mm in the frequency
 
                                       range 5-150Hz

         Mechanical Shock:          Shock accelartion amplitude
                                    of 1g with 10 mS half-sine
                                    pulse. Not to be repeated
                                    more often than one per
                                    ten seconds.

         The units are furthermore able to withstand normal
         use and handling during service and maintenance periods.

         The different pieces of equipmet are designed to operate
         in the comparatively benign environment in normal offices
         or computer rooms. They are therefore able to tolerate
         normal amounts of dust and sand.

         The CR80 equipment itself is very insensitive to normal
         amounts of dust an sand. The only moving parts are
         fan motors and switches, which are all of the encapsulated
         type…86…1          …02…   …02…   …02…   …02…              …02…            
                      
         The peripheral devices like printers and disc drivers
         contain more moving parts, and are therefore basically
         more sensitive to dust and sand. To avoid problems
         these units are therfore supplied with appropriate
         air filters and dust covers.

         In case of high contents of dust and sand the maintenance
         intervals between cleaning and replacement of air filters
         must be shortened.

         The equipment will not be discoloured or emit harful
         substances when exposed to light or normal heating
         sources below 70 deg C.

         All metal parts are adequately protected against corrosion
         in a normal office environment by means of suitable
         forms of painting and plating.…86…1          …02…   …02…   …02…   …02…
                      …02…                          
8.2.3    S̲t̲o̲r̲a̲g̲e̲ ̲a̲n̲d̲ ̲T̲r̲a̲n̲s̲p̲o̲r̲t̲ ̲C̲h̲a̲r̲a̲c̲t̲e̲r̲i̲s̲t̲i̲c̲s̲

         These limits apply to equipment properly packed for
         storage and transport.

         Temperature:               -40 deg C to 70 deg C.

         Relative Humidity:         1%RH - 90%RH, non-condensing

         Absolute Humidity:         0.1g H…0f…2…0e…O/m…0e…3…0f… - 35g H…0f…2…0e…O/m…0e…3…0f…

         Altitude:                  0-10000 m

         Sinusodial Vibration:      Accelaration amplitude of
                                    1.5 g limited by a displacement
                                    amplitude of 10 mm in the
                                    frequency range 5-150 Hz.

         Mehanical Shock:           Shock accelaration amplitude
                                    of 25g with 10mS half-sine
                                    pulse.

Note:    These limits apply to the outer surfaces of the packaging
         container, not to the equipment inside.

         During transport and storage the equipment will be
         properly proected against attacks from fungi,insects
         and rodents by the packaging material.

         Furthermore, the inherent properties of the different
         materials will also prevent such attacks on the equipment
         because they do not contain natural rubber,natural
         fibes etc. …86…1          …02…   …02…   …02…   …02…              …02…     
                             
8.3.     E̲l̲e̲c̲t̲r̲i̲c̲a̲l̲ ̲E̲n̲v̲i̲r̲o̲n̲m̲e̲n̲t̲a̲l̲ ̲C̲h̲a̲r̲a̲c̲t̲e̲r̲i̲s̲t̲i̲c̲s̲

8.3.1    S̲t̲a̲t̲i̲c̲ ̲E̲l̲e̲c̲t̲r̲i̲c̲i̲t̲y̲

         All the equipment will perform their intended functions
         in a normal ESD environment. In order to reduce therisk
         of ESD-induced failures however, high-insulating floors
         should be avoided, and semiconducting floors should
         be used instead.

         The equipment will normally not be affected by a discharge
         through 500 Ohm from a 150 pF capacitor charged to
         5kV.


8.3.2    E̲l̲e̲c̲t̲r̲o̲m̲a̲g̲n̲e̲t̲i̲c̲ ̲W̲a̲v̲e̲s̲

         The equipment will function according to the specifications
         when exposed to an electromagnetic field of 1V/m in
         the frequency range from 30 MHz to 500 MHz.

         The equipment will not radiate electromagnetic waves
         strongr than specified in CISPR B (secr)16.



8.3.3    I̲n̲t̲e̲r̲f̲e̲r̲e̲n̲c̲e̲ ̲o̲n̲ ̲P̲o̲w̲e̲r̲ ̲F̲e̲e̲d̲ ̲L̲i̲n̲e̲s̲

         The equipment is as standard designed to be fed from
         110 V AC source.

         All the equipment is supplied with siutable mains filters
         and are able to sustain noise pulseson main wires with
         amplitudes less than 1000V and rise time longer than
         35nS, pulse duration 0.1 uS to 10uS and repetition
         rate less than one per second.

         The equipment will not emit more interference voltage
         on the mains wires than specified in CSPR B (secr)
         16…86…1          …02…   …02…   …02…   …02…              …02…              
                    
8.3.4    O̲v̲e̲r̲v̲o̲l̲t̲a̲g̲e̲ ̲P̲r̲o̲t̲e̲c̲t̲i̲o̲n̲

         The equipment is not connected directly to the signalling
         lines, but to other equipment which then interfaces
         to the lines.  It is therefore not necesary to provide
         the equipment with special line overvoltage protection
         circuitry.…86…1          …02…   …02…   …02…   …02…              …02…      
                            
8.4      C̲o̲m̲m̲o̲n̲ ̲A̲s̲p̲e̲c̲t̲s̲

8.4.1    S̲a̲f̲e̲t̲y̲

         The CR equipment is designed to meet the requirements
         of IEC 435, Safety of Data Processing Equipment and
         the Danish Safety Regulations.

         Human Sfety considerations have been taken into account
         to protect the operating and maintenance personnel
         against dangerous voltage levels or items with high
         temperature by means of suitable protective covering
         and warning labels. The equipment has also een designed
         to eliminate the possibility of physichal injury to
         the personnel under normal opertaing and maintenance
         conditions..

         Equipment Safety has been taken into account by inherent
         protection against overcurrent and other dangerous
         error cnditions.

         The equipment will not emit dangerous fumes when exposed
         to light or normal heating sources below 70 deg C.

         The equipment is manufactured from self-extinguishing
         materials, but it may still be involved in a fire accident,
         in which cas the equipment will not give off more poisonous
         gases than electronic equipment or building materials
         normally do.

         The acoustic noise emitted from the fan unit or other
         units like terminals and disc drives will not exceed
         70dB(A) re 20uPa measure in a distance of 2m under
         free-field conditions.…86…1          …02…   …02…   …02…   …02…        
              …02…                          
8.4.2    H̲u̲m̲a̲n̲ ̲E̲n̲g̲i̲n̲e̲e̲r̲i̲n̲g̲

         The equipment is designed with great emphasis on human
         engineering aspects to ease the normal use,maintenance
         and repair. The basic design is therefore a odular
         self-contained construction where all normally used
         fuses,switches,controls and displays are located  is
         such a way as to make them easily accesible on front
         or near panels. The colour of LED indicators are standardised,
         Red means alarm or eror, Yellow is a status indicator
         and Green means Power On or Working.



8.4.3    M̲a̲i̲n̲t̲e̲n̲a̲n̲c̲e̲ ̲a̲n̲d̲ ̲R̲e̲p̲a̲i̲r̲

         In the design of the equipment great emphasis has been
         put on maintenance.  Meaning that the system can be
         changed, updated or repaired withoutaffecting the traffic
         handling.

         Repais is very easy due to the modular construction
         where a module can be exchanged without use of special
         tools.  All the modules except the direct interface
         to the lines can be changed without affecting the operaion
         due to the redundancy.  This is applicable for both
         the central processor and the input/output system.

         The design is based upon distributed processing with
         processors in more levels from the CR80 central processor
         configuration to the LTU's. Besides the operational
         work performed by the different processors in the system
         these are also running tests to ensure proper system
         operation.  The principle used in the design of programs
         is to a great extent based upon built-in test, meaning
         tht the modules will perform a self-test when requested
         from the central processor and present a status specifying
         the result of the test.…86…1          …02…   …02…   …02…   …02…       
               …02…                          
         If a failing module is detected, it will, if possible,
         be bypassed and the type and exact position of the
         module will be printed out on the system console so
         that it can be replace by means of an operator. In
         addition to the console print-out specifying the location
         of the failing module, most of the modules have built-in
         light emitting diodes on the front panel which shows
         the status of the module (operating or faulty).

         Wen used, test points will be located at easily accessible
         places on front panels etc. Sensitiive test points
         are protected if misuse can cause serious disturbance.

         Due to the extensive use of microprocessors the system
         can perform basic operation; even if a major part of
         the hardware is out of service.

         The modules are self-contained mechanical units which
         slide into the frame aligned by the frame itself so
         that the contacts are not damaged when modules are
         replaced.

         On the mechanics usd for alignment no limit for exchange
         of modules exists. The connectors used for interfacing
         the modules to the remaining part of the system, normally
         edge connectors, are a high quality type which allow
         for more than 500 module exchanges…86…1          …02…   …02…  
         …02…   …02…              …02…                          
8.4.4    E̲x̲p̲a̲n̲d̲i̲b̲i̲l̲i̲t̲y̲


         The systems are of a modular construction, where the
         modules are mechanical self-contained circuit-boards
         operating in accordance with a set of interface specfications
         which are completely independent of the actual design
         and technology used for implementing the modules' function.

         This means that system extension is very easy to perform
         just by adding the required hardware modules, crates,
         and racks.
8.4.5    S̲y̲s̲t̲e̲m̲ ̲L̲i̲f̲e̲ ̲T̲i̲m̲e̲

         As mentioned above, the modules in the system are designed
         to be compatible with a set of interface specifications
         which covers mechanical, electrical, and functional
         interfaces thereby allowing the modules to be changed
         wih modules of a new generation without adjustments
         and without affecting the remaining part of the system
         soft- or hardware.

         By using this approach in the complete hardware, central
         processor and interface modules, procurement of new
         modules for sstem expansion, and spare parts are not
         dependent on one single manufacturer or a specific
         component and can therefore be guaranteed during the
         long lifetime of the system…86…1          …02…   …02…   …02…   …02…   
                   …02…                          
8.4.6    C̲o̲m̲p̲o̲n̲e̲n̲t̲s̲ 

         The CR80 equipment is designed and produced according
         to detailed internal standards and procedures. This
         practice yields a product of high quality and reliabiliy,which
         has been produced and delivered to several military
         systems.

         The components used in the design are standard components
         available from more than one manufacturer and to a
         great extent MIL-specified and used in military projects
         all over th world which ensures that the components
         will be available on the market during the lifetime
         of the system.

         The critical components are tested to be in accordance
         with the procurement specification, either by the component
         manufacturer or by specal test houses like the Danish
         Elektronikcentralen.

         The electrical design is performed in accordance with
         CR internal standards which ensures that no component
         in the system is overexposed to stressful conditions
         or used under conditions for whic the component is
         not intended, thus securing a very low module failure
         rate.

         The only expendable items are things like air filters,
         fuses and indicator lamps. They are all standard types
         which are readily available.


8.4.7     T̲e̲s̲t̲i̲n̲g̲

          In addition to the test performed on the components
          all units are tested before release from the production
          to comply with the specifications for the unit. This
          testwhich to a great extent is based upon automatic
          test equipment, includes a burn-in test to ensure that
          the initial, comparitively high, failure rate for components
          is removed before the units are released.

          When the units are released they will betested at system
          level before shipment. Upon arrival to the site, the
          units will be installed and integrated in the system
          and thereafter be subject to extensive tests at system
          level.

          Coding straps and jumpers are mounted during the unit
          product