    APPENDIX D


































               A  P  P  E  N  D  I  X    D



           D̲1̲ ̲F̲A̲C̲T̲O̲R̲Y̲ ̲A̲C̲C̲E̲P̲T̲A̲N̲C̲E̲ ̲T̲E̲S̲T̲ ̲P̲R̲O̲C̲E̲D̲U̲R̲E̲





                        1 ̲ ̲G̲E̲N̲E̲R̲A̲L̲



This Factory Acceptance Test procedure defines inspections,
 tests, methods, and equipment required to demonstrate specification
 compliance by Frequency Converter Model 1152-3.





                  2̲ ̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲D̲ ̲D̲O̲C̲U̲M̲E̲N̲T̲



Christian Rovsing A/S / Abacus Controls Inc. Contract dated
 June 26, 1981.





               3̲ ̲ ̲V̲I̲S̲U̲A̲L̲ ̲Q̲U̲A̲L̲I̲T̲Y̲ ̲I̲N̲S̲P̲E̲C̲T̲I̲O̲N̲



Inspect all of the following items for conformance with applicable
 drawings/standards/practices:

Front and rear panels marked per assembly drawing.

Painted surfaces free of dirt and scratches.

Unit serial number affixed.

Sub-assemblies marked per drawings.

Crimp lugs properly attached.

Solder joints clean - no excess solder.

Interior free of chips and debris.

Correct use of hardware stack-ups.





                          - 1 -


              4̲ ̲ ̲T̲E̲S̲T̲ ̲E̲Q̲U̲I̲P̲M̲E̲N̲T̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲S̲



         Q̲T̲Y̲.̲    D̲E̲S̲C̲R̲I̲P̲T̲I̲O̲N̲                 M̲O̲D̲E̲L̲      M̲F̲R̲

         2       AC Voltmeter                2013       Yew
         2       AC Ammeter                  2013       Yew
         1       Distortion Analyzer         330B       H-P
         1       Frequency Counter           IM4100     Heath
         3       Variac                      G-R
         1       Resistive Load              ---        ACI
         1       Inductive Load              ---        ACI
         1       Capacitive Load             ---        ACI
         1       AC Wattmeter                DLW   Sens Research
         1       Current Transformer                    ACI





            5̲ ̲ ̲E̲L̲E̲C̲T̲R̲I̲C̲A̲L̲ ̲P̲E̲R̲F̲O̲R̲M̲A̲N̲C̲E̲ ̲T̲E̲S̲T̲I̲N̲G̲



5.1      L̲i̲n̲e̲ ̲a̲n̲d̲ ̲L̲o̲a̲d̲ ̲R̲e̲g̲u̲l̲a̲t̲i̲o̲n̲ ̲T̲e̲s̲t̲.̲

5.1.1    Connect input line through a variac to the unit under
         test. Connect an AC voltmeter across the input line
         and an AC ammeter in series.

5.1.2    Connect output line through a variac to a resistive
         dummy load. Connect an AC voltmeter across the output
         line and an AC ammeter in series.

5.1.3    Set variac on input for 220 VAC. Set output variac
         to zero. Energize unit by closing input circuit breaker.

5.1.4    Adjust input variac and output variac for input voltages
         and output currents shown on the appropriate Test Data
         Sheet. Enter all measurements required by the Data
         Sheet.

5.2      E̲f̲f̲i̲c̲i̲e̲n̲c̲y̲ ̲T̲e̲s̲t̲.̲

5.2.1    Connect input line through a variac, current transformer
         and AC Wattmeter. Connect output through a variac to
         a resistive dummy load.

5.2.2    Set input variac to 220 VAC and energize unit. Set
         output variac to 40% of full output power and record
         input and output power as required by the Data Sheet.

5.2.3    Calculate efficiency at 60% or better at 40% and 100%
         of full load.


                          - 2 -


5.3      P̲o̲w̲e̲r̲ ̲F̲a̲c̲t̲o̲r̲ ̲T̲e̲s̲t̲.̲

5.3.1    Connect unit output as described in Figure 1 and Table
         1.















  FIGURE 1…01…Test setup for Power Factor Load, Model 52-3




                      ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲


                      ̲ ̲V̲a̲l̲u̲e̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲1̲1̲5̲2̲-̲3̲ ̲ ̲


                       I                         
                      ̲ ̲ ̲T̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲4̲.̲6̲ ̲A̲ ̲ ̲


                       I                        
                      ̲ ̲ ̲X̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲3̲.̲2̲ ̲A̲ ̲ ̲


                      ̲ ̲L̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲2̲2̲0̲ ̲m̲H̲ ̲ ̲


                      ̲ ̲C̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲4̲5̲ ̲u̲f̲ ̲ ̲


                   TABLE 1…01…     Power Factor Test Values




5.3.2    Verify that unit under test performs satisfactory for
         both inductive and capacitive loading.

5.4      O̲v̲e̲r̲l̲o̲a̲d̲ ̲T̲e̲s̲t̲.̲

5.4.1    Apply input power at 220 VAC. Increase output variac
         setting to the Maximum Surge Current stated on the
         Data Sheet. Allow unit to operate for 30 seconds. Record
         input voltage and current and output voltage and current.

5.4.2    Continue to increase output variac setting and verify
         that current limiting occurs as required on the appropriate
         Data Sheet.




                          - 3 -


5.5      L̲i̲f̲e̲ ̲T̲e̲s̲t̲.̲

5.5.1    Connect the Frequency Converter with input at 220 VAC
         and output on a resistive load as required by the Test
         Data Sheet. Energize unit and record input and output
         voltage and current on the Data Sheet.

5.5.2    At the conclusion of 16 hours minimum, again record
         input and output voltage and current. Remove unit from
         life test.














































                          - 4 -


                    D̲2̲ ̲T̲E̲S̲T̲ ̲D̲A̲T̲A̲ ̲S̲H̲E̲E̲T̲





               1̲ ̲ ̲V̲I̲S̲U̲A̲L̲ ̲Q̲U̲A̲L̲I̲T̲Y̲ ̲I̲N̲S̲P̲E̲C̲T̲I̲O̲N̲



Refer to paragraph 3.0 of Factory Acceptance Test Procedures
 (D1) and perform a careful inspection of the equipment as described
 therein.

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ PASS          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ FAIL





             2̲ ̲ ̲L̲I̲N̲E̲ ̲A̲N̲D̲ ̲L̲O̲A̲D̲ ̲R̲E̲G̲U̲L̲A̲T̲I̲O̲N̲ ̲T̲E̲S̲T̲



Refer to paragraph 5.1 of Contract Test Procedures and record
 all of the data required below. Fill in all blank spaces. (See
 next page).





























                     - 1 -…01…Data Sheet



         E        I        E        I        
          ̲I̲N̲       ̲I̲N̲       ̲O̲U̲T      ̲O̲U̲T     %̲ ̲T̲H̲D̲    F̲r̲e̲q̲.̲

         1̲8̲7̲       ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲0̲ ̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲

         2̲2̲0̲       ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲0̲ ̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲

         2̲4̲2̲       ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲0̲ ̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲

         1̲8̲7̲       ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲3̲,̲4̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲

         2̲2̲0̲       ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲3̲,̲4̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲

         2̲4̲2̲       ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲3̲,̲4̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲

         1̲8̲7̲       ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲4̲,̲7̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲

         2̲2̲0̲       ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲4̲,̲7̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲

         2̲4̲2̲       ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲4̲,̲7̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲

         2̲0̲4̲       ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲0̲ ̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲

         2̲4̲0̲       ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲0̲ ̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲

         2̲6̲4̲       ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲0̲ ̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲

         2̲0̲4̲       ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲3̲,̲4̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲

         2̲4̲0̲       ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲3̲,̲4̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲

         2̲6̲4̲       ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲3̲,̲4̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲

         2̲0̲4̲       ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲4̲,̲7̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲

         2̲4̲0̲       ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲4̲,̲7̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲

         2̲6̲4̲       ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲4̲,̲7̲     ̲ ̲ ̲ ̲ ̲     ̲ ̲ ̲ ̲ ̲
















                     - 2 -…01…Data Sheet


         Output voltage is between 210 V and 230 V?

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ PASS          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ FAIL

         Output frequency is between 49,9 and 50,1 Hz?

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ PASS          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ FAIL

         Total harmonic distortion is no greater than 5?

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ PASS          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ FAIL





                    3̲ ̲ ̲E̲F̲F̲I̲C̲I̲E̲N̲C̲Y̲ ̲T̲E̲S̲T̲



         Refer to paragraph 5.2 of Factory Acceptance Test Procedures
         and measure efficiency of the Frequency Converter.
         Enter results below.

         Set Output Power at 40% of full load, (220 volts and
         1.85 A) to obtain output power of 407 VA.

         INPUT POWER  ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ WATTS

         EFFICIENCY = (407 / INPUT POWER) X 100 =  ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ PASS           ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ FAIL

         See Output Power at 100% of full load, (220 volts and
         4.6 A) to obtain output power of 1012 VA.

         INPUT POWER  ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ WATTS

         EFFICIENCY = (1012 / INPUT POWER) X 100 =  ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ PASS           ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ FAIL





                   4̲ ̲ ̲P̲O̲W̲E̲R̲ ̲F̲A̲C̲T̲O̲R̲ ̲T̲E̲S̲T̲



         Refer to paragraph 5.3 of Factory Acceptance Test Procedures
         and operate the Frequency Converter as described in
         Figure 1 and Table 1. Verify that unit continues operation.

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ PASS           ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ FAIL


                          - 3 -
                        Data Sheet


                     5̲ ̲ ̲O̲V̲E̲R̲L̲O̲A̲D̲ ̲T̲E̲S̲T̲



         Refer to paragraph 5.4 of Factory Acceptance Test Procedures
         and operate the Frequency Converter in the overload
         condition as described.

         Unit sustains a 14 A load for 30 seconds?

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ PASS           ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ FAIL

         Unit will not supply more than 16 amperes?

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ PASS           ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ FAIL





                       6̲ ̲ ̲L̲I̲F̲E̲ ̲T̲E̲S̲T̲



         Refer to paragraph 5.5 of Factory Acceptance Test Procedures
         and operate the Frequency Converter for 16 hours at
         output current of 4.6 Amperes, nominal.


         TEST STARTED AT  ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ON  ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         INPUT VOLTS  ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ INPUT CURRENT  ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         OUTPUT VOLTS  ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ OUTPUT CURRENT  ̲
         ̲ ̲ ̲ ̲ ̲ ̲


         TEST ENDED AT  ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ON  ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         INPUT VOLTS  ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ INPUT CURRENT  ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         OUTPUT VOLTS  ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ OUTPUT CURRENT  ̲
         ̲ ̲ ̲ ̲ ̲ ̲







         THE UNDERSIGNED CERTIFY THAT THE INFORMATION IN THIS
         TEST DATA SHEET IS TRUE AND ACCURATE.


         TEST TECHNICIAN  ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ STAMP  ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         CUSTOMER REP.    ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ STAMP  ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲



                          - 4 -
                        Data Sheet