⟦a6ce5a786⟧ Wang Wps File

    Length: 4699 (0x125b)
    Types: Wang Wps File
    Notes: Spelunked
    Names: »~ORPHAN66.00«

Derivation

└─⟦61695b6f0⟧ Bits:30006170 8" Wang WCS floppy, CR 0291A
    └─ ⟦this⟧ »~ORPHAN66.00« 

WangText

Z…00……00……00……00…B…02……00……00…B
B…05…A…08…A…0d…A…00…A @…09…@…0c…@…0d…@…02…@…07…?…0b…?…00…? >…09…>…0a…>…0e…>…01…>…05…=…0a…=…0e…=
=…07…<…0b…<…00…<…05…;…08…;…0d…;…01…;…05…:…09…:…0d…:…02…:…06…9…0b…9…00…9…05…8…0a…8…0f……86…1                                             …02…           …02…   …02…    
    

    2891A/rt       …02… CPS/OPM/003

…02… CLA/840801…02……02… 
CAMPS MDCO OPERATION MANUAL
…02… Issue 2 …02…CAMPS



  2.3.3  Initial Setup          








  1    Verify that the MSP is        Figure 2.2.3-1.a.
       installed and connected
       and that the circuit breaker
       and power switch are OFF.

  2    Verify hat the ribbon is      Refer to Sec. 2.2.2.
       properly installed.

  3    Load the unit with            Refer to Sec. 2.2.2.
       paper.…86…1  …02…    …02…                             …02…  …02… 
                             
  2.3.3  Initial Setup  (cont'd)








  4    Turn the audio control        Refer to Figure
                                     2.2.3-2.a.
       on the front panel
       to the                        
       loudest position.

  5    Set all facility circuit      Refer t Figure 2.2.3-1.a.
       breakers for this set
       to ON. Set the TCM power
       switch to ON.

  6    Verify that the POWER lamp    Refer to Figure
                                     2.2.3-2.b.
       on the front panel lights.

  7    Insert the security key in    Refer to Figure
                                     2.2.3-2.c.
       the key-lock an turn to
       the ON position.…86…1  …02…    …02…                      
             …02…  …02…                        
  2.3.3  Initial Setup  (cont'd)








  8    Depress the LINE FEED push    Refer to Figure
                                     2.2.3-3.a.
       button on the TCM front       Verify that one
                                     line feed
       panel for at least one        of papr occurs,
                                     followed by
       second.                       continuous line
                                     feeds for as
                                     long as the LINE
                                     FEED push
                                     button is depressed.

  9    Continue to depress the       Refer to Figure
                                     2.2.3-3.a.
       LINE FEED push button for
       single line feeds until
       the serrated edge of oe
       sheet passes the print-
       head by 3 to 6 lines.

  10   Depress the FORM FEED button  Refer to Figure
                                     2.2.3-3.b.
       on the TCM front panel.       Verify the paper
                                     feeds to the same
                                     popsition on the
                                     next sheet. This
                                     operation establishes
                                     the form feed posiion.

  11   Depress the TEST push button  Refer to Figure
                                     2.2.3-3.c.
       on the TCM front panel for    Verify that the
                                     following
       at least 5 seconds.           is printed:

                                     NO ERRORS IN ROM
                                     NO ERRORS IN RAM

                                     (Printer prints
                                     66 lines barberpole
                                     pattern). (Tere
                                     may be a time delay
                                     between printouts).…86…1
                                      …02…    …02…          
                                                    
                                       …02…  …02…           
                                                 
  2.3.3  Initial Setup  (cont'd)








                                     The MSP is now ready
                                     to receive message
                                     traffic from the
                                     line. Arrange to
                                     have one or more
                                     messages sent to
                                     the MSP and verify
                                     message cotent with
                                     the transmitting
                                     station. During
                                     this time, the key-lock
                                     switch should be
                                     tested by setting
                                     it to the OFF position
                                     and verifying printing
                                     has stopped. The
                                     CAMPS system is
                                     able to verify when
                                     the switch has been
                                     set to ON.

  12   Set the keylock switch to     Refer to Figure
                                     2.2.3-4.a.
       OFF.

  13   Remove the key.               Refer to Figure
                                     2.2.3-4.a.

         ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ 
       ^W̲A̲R̲N̲I̲N̲G̲^ Do not operate the
       MSP with the cover open.…86…1  …02…    …02…              
                     …02…  …02…                        
  3.1.1  Sign On (SION) (cont'd)








                                     After the boot sequence
                                      and start up procedure
                                     from the maintenance
                                     position is finished,
                                     the system will
                                     present you for
                                     a standard layut
                                     on the VDU screen.
                                     Refer to Figure
                                     3.1.1-1.

  1    On keyboard, press the        Refer to Figure
                                     3.1.1-2.a.
       control function key-         Pressing the ATTN-key
                                     causes
       ATTN                          the VDU to present
                                     ENTER in the system
                                     line. The cursor
                                     will be found in
                                     the system ine and
                                     await a command
                                     code.

  2    On keyboard, enter the
       command code SION.

  3    Press ENTER key               Refer to Figure
                                     3.1.1-2.a.

  4    On keyboard, enter your       The identification
                                     code and
       3 letter ID code and          the password will
                                     NOT be
       your 8 letter pasword.        displayed on the
                                     screen.
                                     Comma or space are
                                     used as
                                     separator.

  5    Press ENTER key               Refer to Figure
                                     3.1.1-2.b.



 3.1.1  Sign On (SION) (cont'd)








  6    If you enter invalid ID       Blocking the terminal
                                     will
       code or password, you must    take place after
                                     three
       go back to step 4 and try     invald attempts.
       again.

  7    If the terminal displays      If the actual terminal
                                     also
       BLOCKED in the response       have supervisor
                                     capability,
       line, proceed either to       real blocking of
                                     the terminal
       step 1 and try again or       will never take
                                     place. You
       contat supervisor for         must press the Attn-key,
       further help.                 which will bring
                                     you back
       Otherwise, proceed to         to sign on mode
                                     again.
       step 8.                       Otherwise, you must
                                     contact supervisor
                                     for further help.

  8    Proceed either to sec-        When the sign-on
                                     procedre
       tion HIGH LEVEL MENU          is OK, the system
                                     will pre-
       or section SECURITY           sent you for the
                                     high level
       PROCEDURES, dependent         menu or the MDCO
                                     menu.
       on what the system            If high level menu
                                     is
       displays.                     presented proceed
                                     to the high level
                                     menu