…02… CPS/TCM/006
…02… LU/830307…02……02…#
VDU MAINTENANCE MANUAL, VOL. I
(Peripheral Equipment Manual)…02… Issue 1…02… CAMPS
VDU MAINTENANCE MANUAL, VOL.I
(Peripheral Equipment Manual)
CPS/TCM/006
CDRL Documentation No. 03
Line Item No. 9.3
Leif Uldam
Kurt Nybroe-Nielsen
SHAPE (5), each Site (2), NCS (20), GJ, BHB,
LU, QA, KNN,
Conf. Mgmt., PMS, KM, CL, Library (5).
ILS Manager 830307
2
830307 Conf.Mgm. 820307
…02… CPS/TCM/006
…02… LU/830307…02…ii…02…VDU MAINTENANCE MANUAL, VOL. I
(Peripheral Equipment Manual)…02… Issue 1…02… CAMPS
…02… CPS/TCM/006
…02… LU/830307…02……02…iii
VDU MAINTENANCE MANUAL, VOL.I
(Peripheral Equipment Manual) …02… Issue 1…02… CAMPS
820928 All Issue 1
Issue 1 830307 All Rearrangement of pages…86…1
…02… …02… …02… …02…
T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲
TITLE PAGE ................................ i
FIRST AID FOR ELECTRICAL SHOCK ............ ii
REVISION RECORD ........................... iii
TABLE OF CONTENTS ......................... iv
1. SCOPE ................................. 1
2. APPLICABLE DOCUMENTS .................. 2
3. VDU PC CARDS USED WITH CAMPS .......... 3
4. VDU MAINTENANCE MANUAL, VOL.1.......... 4…86…1
…02… …02… …02… …02…
1. S̲C̲O̲P̲E̲
This Manual includes procedures for both site and depot
level Maintenance.
The procedures which apply to site level are those
in the following sections:
3.2 Troubleshooting Guide
3.2.1(a), (b), (c), (d), (e), (g), and (h)
3.2.3.2 Message Problems
3.2.4 Keyboard Faults
3.2.5 Other Faults
3.3 Video Display Alignment
N̲o̲t̲e̲: 3.2.1(F) is Depot Level
All other Sections apply to Depot Level o̲n̲l̲y̲, and
repairs must not be attempted otherwise PCBs may be
damaged beyond repair.
See Section 3.2.3.1 Raster Problems.If faults are anything
other than the DMM board it is sent to depot for repair.
See Table 3-1 Spares and Tools. Tools and Spares in
this table are not those provided.…86…1 …02… …02… …02…
…02…
2. A̲P̲P̲L̲I̲C̲A̲B̲L̲E̲ ̲D̲O̲C̲U̲M̲E̲N̲T̲S̲
1. VDU OPERATORS MANUAL
CPS/OPM/007
2. VDU REFERENCE MANUAL
CPS/REM/001
3. VDU MAINTENANCE MANUAL, VOL. II
CPS/TCM/006
4. VDU MAINTENANCE MANUAL, VOL. II
CPS/TCM/007
(This manual is only applicable to depot)
3. V̲D̲U̲ ̲C̲A̲R̲D̲S̲ ̲U̲S̲E̲D̲ ̲W̲I̲T̲H̲ ̲C̲A̲M̲P̲S̲
The VDU Cards used with CAMPS are as follows:
̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
MODULE PART NUMBER DWG. NUMBER
̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
PMM 785A302U02 LD-18-1017
DMM 785A262U04 LD-18-1002
IOM 785A303U02 LD-18-1018
Keyboard Logic Card 785A247U01 LD-18-1007
CRT CRL.Card 785A220U07 SC-15-1031
Power Supply 798A022U02 SC-18-1011
̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
̲ ̲ ̲ ̲ ̲ ̲ ̲
4. V̲D̲U̲ ̲M̲A̲I̲N̲T̲E̲N̲A̲N̲C̲E̲ ̲M̲A̲N̲U̲A̲L̲,̲ ̲V̲O̲L̲.̲ ̲1̲
for the
T̲y̲p̲e̲ ̲7̲2̲6̲0̲T̲ ̲(̲C̲/̲B̲)̲
D̲e̲l̲t̲a̲ ̲D̲a̲t̲a̲ ̲V̲D̲U̲
Delta Data Docu. No. 917M200A020
This Manual is arranged in three main sections:
1. System Overview
2. Theory of Operation
3. Maintenance and Alignment
The blocked Schematics are contained in the VDU Maintenance
Manual, V̲O̲L̲.̲ ̲2̲.
(The VDU Maintenance Manual Vol.I is included in the
following)