⟦aa04c66aa⟧ Wang Wps File

    Length: 15677 (0x3d3d)
    Types: Wang Wps File
    Notes: CPS/SDS/043               
    Names: »1874A «

Derivation

└─⟦796ed5a45⟧ Bits:30006090 8" Wang WCS floppy, CR 0142A
    └─ ⟦this⟧ »1874A « 

WangText




…02…CPS/SDS/043

…02…CSV/830126…02…#
REMOTE TARE HARDWARE ASSEMBLY BREAKDOWN/
HARDWARE TREE…02…Issue 1…02…CAMPS









                 T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲



   1  INTRODUCTION ..................................
      4

     1.1  SCOPE .....................................
        4
     1.2  INDENTURE LEVELS ..........................
        4
     1.3  FIGURE EXPLANATION ........................
        5
     1.4  TABLE EXPLANATION .........................
        7

   2  HARDWARE BREAKDOWN ............................
      8

     2.1  FIGURES ...................................
        8
       2.1-1  Indenture Levels ......................
          8
       2.1-2  Remote Tare Rack Configuration and
              Breakdown Level 1 and 2 ...............
            9
       2.1-3  V24 BPJF ..............................
         10
       2.1-4  VF BPJF ...............................
         11
       2.1-5  Modem .................................
         12
       2.1-6  Mains Switch ..........................
         13
       2.1-7  Power Distribution Panel ..............
         14
       2.1-8  Power Intel Box .......................
         15
       2.1-9  Cabinet Assembly ......................
         16
       2.1-10 Cable Diagram .........................
         17
       2.1-11 Cable Illustrations ...................
         18
       2.1-12 Cable Diagram .........................
         19

     2.2  TABLES ....................................
       20

       2.2-1  Remote Tare Assembly (1A1) ............
         20
       2.2-2  V24 BPJF ..............................
         22
       2.2-3  Cabinet Assembly (1A2) ................
         23


   3  APPENDICES ....................................
     25

     3.1  SITE NO./SITE NAME ........................
       25
     3.2 CR LABELS ..................................
           26
     3.3  ACCESSIBLE FUSES USED IN REMOTE TARE RACK .
       30
     3.4  LIST OF SCREWS, WASHERS AND NUTS ..........
       31


                     1̲ ̲ ̲I̲N̲T̲R̲O̲D̲U̲C̲T̲I̲O̲N̲



1.1      S̲C̲O̲P̲E̲

         This Assembly Breakdown illustrates and lists the Hardware
         in the 7 Remote Tare Racks, Remote Site.

         The Hardware in the Remote Tare Racks, Main Site is
         illustrated and listed in CAMPS Hardware Assembly Breakdown,
         Hardware tree CPS/SDS/017.

         The purpose of this Document is to assist assembly,
         supply, maintenance, and overhaul personel in the identification
         of replaceable parts.

         This Hardware Assembly Breakdown/Hardware tree is made
         according to reference designations for electrical
         and electronics parts and equipment standard USAS Y
         32.16-1968.



1.2      I̲N̲D̲E̲N̲T̲U̲R̲E̲ ̲L̲E̲V̲E̲L̲S̲

         In order to specify an exact equipment location, every
         piece of equipment is given a reference designation
         number. The reference designation number is based on
         the branch numbers in the hardware tree. In this hardware
         assembly breakdown, the hardware tree is broken down
         in up to 4 indenture levels.

         I̲n̲d̲e̲n̲t̲u̲r̲e̲ ̲L̲e̲v̲e̲l̲ ̲1̲ is the system broken down into units.

         I̲n̲d̲e̲n̲t̲u̲r̲e̲ ̲L̲e̲v̲e̲l̲ ̲2̲ consists for example of a breakdown
         of a unit into rack equipment assemblies and Cabinet
         assembly.

         I̲n̲d̲e̲n̲t̲u̲r̲e̲ ̲l̲e̲v̲e̲l̲ ̲3̲ is for example a split up of a rack
         equipment assembly into crate assemblies, electronic
         equipment and mechanics.

         I̲n̲d̲e̲n̲t̲u̲r̲e̲ ̲l̲e̲v̲e̲l̲ ̲4̲ is for example a split up of a crate
         assembly into PC-board modules and mechanics.



         E̲x̲a̲m̲p̲l̲e̲ ̲o̲n̲ ̲R̲e̲f̲e̲r̲e̲n̲c̲e̲ ̲D̲e̲s̲i̲g̲n̲a̲t̲i̲o̲n̲ ̲N̲u̲m̲b̲e̲r̲:̲

         Indenture Level 1, (Unit no. 1)
             Indenture Level 2 (Cabinet Assembly A2)
                 Indenture Level 3 (position A1)
                     Indenture Level 4 (position A3)

          1  A2  A1  A3

         The above Reference Designation points out Patch Block
         in the V24 Black Patch Jack Field.

         The letter A is used to separate the branch numbers.
         The branch numbers are made out from the physical configuration
         except for the unit numbers. Numbering goes from left
         to right and start in top of the equipment.



1.3      F̲I̲G̲U̲R̲E̲ ̲E̲X̲P̲L̲A̲N̲A̲T̲I̲O̲N̲

         "̲R̲E̲F̲.̲N̲O̲.̲"̲ ̲C̲O̲L̲U̲M̲N̲

         The Ref. No. Column Lists the illustrated Assemblies
         Reference Designation Numbers.

         "̲T̲A̲B̲L̲E̲"̲ ̲C̲O̲L̲U̲M̲N̲

         This column refer to Subassembly lists.

         "̲N̲H̲A̲ ̲T̲A̲B̲L̲E̲"̲ ̲C̲O̲L̲U̲M̲N̲

         The NHA (Next Higher Assembly) Table Column refers
         to the tables in which the assembly is included.









































!







                       FIGURE 1.3-1
                      FIGURE EXAMPLE


1.4      T̲A̲B̲L̲E̲ ̲E̲X̲P̲L̲A̲N̲A̲T̲I̲O̲N̲

         "̲F̲I̲G̲.̲"̲ ̲C̲O̲L̲U̲M̲N̲

         The numbers in this column refers to an illustration
         of the item. The referenced Figure is included in the
         same headsection.

         "R̲E̲F̲.̲ ̲N̲O̲.̲"̲ ̲C̲O̲L̲U̲M̲N̲

         This column lists the Reference Designation Numbers.

         "̲P̲A̲R̲T̲ ̲N̲U̲M̲B̲E̲R̲"̲ ̲C̲O̲L̲U̲M̲N̲

         The numbers in this column are Christian Rovsing part
         numbers.

         "̲D̲E̲S̲C̲R̲I̲P̲T̲I̲O̲N̲"̲ ̲C̲O̲L̲U̲M̲N̲

         This column lists the names of all parts included in
         the illustrated components list.

         "̲A̲P̲P̲L̲I̲C̲A̲B̲L̲E̲ ̲F̲O̲R̲ ̲S̲I̲T̲E̲ ̲N̲O̲:̲"̲ ̲C̲O̲L̲U̲M̲N̲

         This column indicates limited use of an item in respect
         to site configurations.























                       FIGURE 1.4-1


                  2̲ ̲ ̲H̲A̲R̲D̲W̲A̲R̲E̲ ̲B̲R̲E̲A̲K̲D̲O̲W̲N̲



2.1      F̲I̲G̲U̲R̲E̲S̲












































              FIGURE 2.1-1…01…INDENTURE LEVELS

















































FIGURE 2.1-2…01…REMOTE TARE (REMOTE SITE) CONFIGURATION AND…01…BREAKDOWN 1 AND
 2


         R̲E̲F̲.̲N̲O̲.̲ ̲ ̲T̲A̲B̲L̲E̲ ̲ ̲N̲H̲A̲ ̲T̲A̲B̲L̲E̲
         1̲A̲1̲A̲1̲ ̲ ̲ ̲ ̲2̲.̲2̲-̲2̲ ̲ ̲2̲.̲2̲-̲1̲ ̲ ̲ ̲ ̲











































         FIGURE 2.1-3…01…V24 BLACK PATCH JACK FIELD


         R̲E̲F̲.̲N̲O̲.̲ ̲ ̲T̲A̲B̲L̲E̲ ̲ ̲N̲H̲A̲ ̲T̲A̲B̲L̲E̲
         1̲A̲1̲A̲2̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲2̲.̲2̲-̲1̲ ̲ ̲ ̲ ̲
















































          FIGURE 2.1-4…01…VF BLACK PATCH JACK FIELD


         R̲E̲F̲.̲N̲O̲.̲ ̲ ̲T̲A̲B̲L̲E̲ ̲ ̲N̲H̲A̲ ̲T̲A̲B̲L̲E̲
         1̲A̲1̲A̲3̲ ̲ ̲ ̲        2.2-1    
         1̲A̲1̲A̲4̲ ̲ ̲ ̲                 
         1̲A̲1̲A̲5̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲













































                    FIGURE 2.1-5…01…MODEM


         R̲E̲F̲.̲N̲O̲.̲ ̲ ̲T̲A̲B̲L̲E̲ ̲ ̲N̲H̲A̲ ̲T̲A̲B̲L̲E̲
         1̲A̲1̲A̲6̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲2̲.̲2̲-̲1̲ ̲ ̲ ̲ ̲














































                FIGURE 2.1-6…01…MAINS SWITCH


         R̲E̲F̲.̲N̲O̲.̲ ̲ ̲T̲A̲B̲L̲E̲ ̲ ̲N̲H̲A̲ ̲T̲A̲B̲L̲E̲
         1̲A̲1̲A̲7̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲2̲.̲2̲-̲1̲ ̲ ̲ ̲ ̲
















































          FIGURE 2.1-7…01…POWER DISTRIBUTION PANEL


         R̲E̲F̲.̲N̲O̲.̲ ̲ ̲T̲A̲B̲L̲E̲ ̲ ̲N̲H̲A̲ ̲T̲A̲B̲L̲E̲
         1̲A̲1̲A̲8̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲2̲.̲2̲-̲1̲ ̲ ̲ ̲ ̲













































               FIGURE 2.1-8…01…POWER INLET BOX


         R̲E̲F̲ ̲N̲O̲.̲ ̲ ̲ ̲ ̲T̲A̲B̲L̲E̲ ̲ ̲ ̲ ̲N̲H̲A̲ ̲T̲A̲B̲L̲E̲
         1̲A̲2̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲2̲.̲2̲-̲3̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
















































              FIGURE 2.1-9…01…CABINET ASSEMBLY

















































          FIGURE 2.1-10…01…MOUNTING OF GROUND WIRE


















































            FIGURE 2.1-11…01…CABLE ILLUSTRATIONS


















































  FIGURE 2.1-12…01…REMOTE TARE, SITE INTERNAL CABLE DIAGRAM



2.2 T̲A̲B̲L̲E̲S̲




             TABLE 2.2-1  (FIGURE 2.1-2)

REMOTE TARE ASSEMBLY (1A1),  LISTING OF INDENTURE LEVEL 3 ASSEMBLIES


 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

                                            APPLICABLE
                                            FOR SITE NO.:

FIG.        REF.NO.     PART NO.            DESCRIPTION   1 2 3 4 5  
                                                                       
                                                                        

 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

2.1-        1A1-

3   A1      N/A         V24 BPJF                X X X X X 
                                                            
                                                              

4   A2      5.39400-00  VF BPJF                 X X X X X 
                                                            
                                                              

5   A3      4.32700-00  MODEM                   X X X X X 
                                                            
                                                              

5   A4      4.32700-00  MODEM                     X     X 

5   A5      4.32700-00  MODEM                     X

6   A6      4.07025-00  MAINS SWITCH 220V       X X X X X 
                                                            
                                                              

7   A7      4.39100-00  POWER DIST. PANEL       X X X X X 
                                                            
                                                              

8   A8      5.05453-00  POWER INLET BOX         X X X X X 
                                                            
                                                              

11  W1      5.05422-02  V24 CABLE 10B/060       X X X X X 
                                                            
                                                              

11  W2      5.05422-02  V24 CABLE 10B/060         X     X 

11  W3      5.05422-02  V24 CABLE                 X 

11  W4      5.05466-00  VF CABLE                X X X X X 
                                                            
                                                              

11  W5      5.05466-00  VF CABLE                  X     X

11  W6      5.05466-00  VF CABLE                  X





          TABLE 2.2-1  (FIGURE 2.1-2) Cont.

REMOTE TARE ASSEMBLY (1A1),  LISTING OF INDENTURE LEVEL 3 ASSEMBLIES


 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

                                            APPLICABLE
                                             FOR SITE NO.:

FIG.        REF.NO.     PART NO.            DESCRIPTION   1 2 3 4 5  
                                                                       
                                                                        

 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

11  W10     N/A         POWER CABLE
                        PART OF 1A1A3

11  W11     N/A         POWER CABLE
                        PART OF 1A1A4

11  W12     N/A         POWER CABLE
                        PART OF 1A1A5

11  W13     N/A         POWER CABLE
                        PART OF 1A1A7

11  W14     N/A         POWER CABLE
                        PART OF 1A1A8




             TABLE 2.2-2  (FIGURE 2.1-3)

V24 BPJF (1A1A1),  LISTING OF INDENTURE LEVEL 4 ASSEMBLIES


 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

                                            APPLICABLE
                                             FOR SITE NO.:

FIG.        REF.NO.     PART NO.            DESCRIPTION   1 2 3 4 5  
                                                                       
                                                                       

 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

    1A1A1

    A1      5.39604-02  FRONT PANEL, BPJF       X X X X X   

    A2      6.39400-00  PATCH BLOCK DP12-5      X X X X X   

    A3      6.39400-00  PATCH BLOCK DP12-5        X     X

    A4      6.39400-00  PATCH BLOCK DP12-5        X




             TABLE 2.2-3  (FIGURE 2.1-8)

CABINET ASSEMBLY (1A2),  LISTING OF INDENTURE LEVEL 3 ASSEMBLIES


 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

                                            APPLICABLE
                                             FOR SITE NO.:

FIG.        REF.NO.     PART NO.            DESCRIPTION   1 2 3 4 5  
                                                                       
                                                                       

 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

    1A2-

    A1      4.44504-00  RACK 36 U               X X X X X   
                        (550 MM DEEP)

    A2      7.47605-00  DUAL UNIT SHELF         X X X X X   

    A3      7.47605-00  DUAL UNIT SHELF           X

    A4      6.01401-02  SUPP. SLIDE, LEFT       X X X X X   

    A5      6.01401-01  SUPP. SLIDE, RIGTH      X X X X X   

    A6      6.01401-02  SUPP. SLIDE, LEFT       X X X X X   

    A7      6.01401-01  SUPP. SLIDE, RIGTH      X X X X X   

    A8      6.01401-02  SUPP. SLIDE, LEFT         X   
                                                        
                                                            

    A9      6.01401-01  SUPP. SLIDE, RIGTH        X   
                                                        
                                                            

    W20     5.05419-03  GND WIRE A/66
                        BETWEEN PANEL
                        MOUNTING RAILS          X X X X X   

    W21     5.05419-03  GND WIRE A/66
                        BETWEEN PANEL
                        MOUNTING RAILS          X X X X X   

    W22     5.05419-02  GND WIRE A/55
                        BETWEEN PANEL
                        MOUNTING RAILS          X X X X X   

    W23     5.05419-02  GND WIRE A/55
                        MODEM TO PANEL
                        MOUNTING RAIL           X X X X X   




          TABLE 2.2-3  (FIGURE 2.1-8) Cont.

CABINET ASSEMBLY (1A2),  LISTING OF INDENTURE LEVEL 3 ASSEMBLIES


 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

                                            APPLICABLE
                                             FOR SITE NO.:

FIG.        REF.NO.     PART NO.            DESCRIPTION   1 2 3 4 5  
                                                                       
                                                                       

 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

    W24     5.05419-02  GND WIRE A/55
                        MODEM TO PANEL
                        MOUNTING RAIL             X     X 

    W25     5.05419-02  GND WIRE A/55
                        MODEM TO PANEL
                        MOUNTING RAIL             X

    W26     N/A         GND WIRE
                        PART OF 1A1A6       



                      3̲ ̲ ̲A̲P̲P̲E̲N̲D̲I̲C̲E̲S̲



3.1      S̲I̲T̲E̲ ̲N̲O̲.̲/̲S̲I̲T̲E̲ ̲N̲A̲M̲E̲

         SITE NO.    SITE NAME
          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         1           KOLSAAS
         2           MAASTRICHT
         3           NORTHWOOD
         4           PITREAVIE
         5           BAUMHOLDER
          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲


3.2      C̲R̲ ̲L̲A̲B̲E̲L̲S̲

         Part of the equipment is marked with labels for identification.
         The different label types and their location is shown
         in section 3.2.1 to 3.2.4.


3.2.1    P̲A̲R̲T̲ ̲N̲O̲.̲/̲ ̲S̲E̲R̲I̲A̲L̲ ̲N̲O̲.̲ ̲L̲A̲B̲E̲L̲

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
          ̲ ̲ ̲P̲/̲N̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲S̲/̲N̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

         FIGURE 3.2.1-1.  PART NO./SERIAL NO.LABEL

         This label is used for telling the items CR part no.
         and serial no.

         The label is used on all * CR products except pure
         mechanical items. Cables are only marked with the part
         no. section.

         Items where the label is not visible after integration,
         have the serial no section repeated on a visible place.


3.2.2    E̲C̲O̲ ̲S̲T̲A̲T̲U̲S̲ ̲L̲A̲B̲E̲L̲

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
          ̲E̲C̲O̲ ̲S̲T̲A̲T̲U̲S̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲A̲ ̲B̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
          ̲E̲C̲O̲ ̲S̲T̲A̲T̲U̲S̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲L̲ ̲M̲ ̲N̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

         FIGURE 3.2.2-1 ECO STATUS LABELS.


         This label is used for telling the engineering change
         order (ECO) status. On the space is printed the baseline
         (on PCBs the baseline is equal to the revision no.).
         The letters refer to ECOs. The crossed out letters
         indicate implemented ECOs.

         The label is used on all * CR products with serial
         no.

         NOTE* For future print circuit board (PCB) work revisions,
         the label data will be etched and angraved directly
         in PC-board.



3.2.3    I̲D̲E̲N̲T̲I̲F̲I̲C̲A̲T̲I̲O̲N̲ ̲L̲A̲B̲E̲L̲





















         FIGURE 3.2.3-1. IDENTIFICATION LABEL.

         The identification label is used for marking major
         assemblies. It is used on each CAMPS rack and on the
         PTP/PTR.

         The spaces on the identification label are filled in
         with the following data:

         S̲I̲T̲E̲                         KOLSAAS
                                         '
                                         '
                                      BAUMHOLDER

         T̲Y̲P̲E̲                         REMOTE TARE RACK


         P̲R̲O̲J̲E̲C̲T̲                      CAMPS


         C̲O̲N̲T̲R̲A̲C̲T̲ ̲N̲O̲.̲                 CE-80-9009-INF (CAMPS)


         F̲A̲C̲T̲O̲R̲Y̲ ̲A̲C̲C̲E̲P̲T̲A̲N̲C̲E̲
         T̲E̲S̲T̲ ̲D̲A̲T̲E̲                    "MONTH"/"YEAR"



         The dates are filled in by using a typewriter.

         Location of the identification label is shown on figure
         3.2.3-2

                                                       REM.TARE
 RACK 




















                                                         REAR
 DOOR   



                      FIGURE 3.2.3-2

           LOCATION OF THE IDENTIFICATION LABEL





3.2.4    N̲A̲M̲E̲ ̲P̲L̲A̲T̲E̲S̲


          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲R̲E̲M̲O̲T̲E̲ ̲T̲A̲R̲E̲ ̲R̲A̲C̲K̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲



         FIGURE 3.2.4-1. Name plate for Remote Tare Rack

         The name plate is placed on the upper front panel,
         see figure 3.2.4-2


                                           REMOTE TARE RACK















              FIGURE 3.2.4-2
              NAME PLATE LOCATION
              ON REMOTE TARE RACK





                        TABLE 3.3
        ACCESSIBLE FUSES USED IN REMOTE TARE RACK


     LOCATION                      FUSE DESCRIPTION
      ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

     NAME                 REF NO. I/U        MECH. DIM     CR
 P/N

      ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

     MODEM                F1      0,5AT/250  5 x 20 mm




3.4      S̲C̲R̲E̲W̲S̲,̲ ̲W̲A̲S̲H̲E̲R̲S̲,̲ ̲A̲N̲D̲ ̲N̲U̲T̲S̲ ̲U̲S̲E̲D̲ ̲F̲O̲R̲ ̲I̲N̲T̲E̲G̲R̲A̲T̲I̲O̲N̲



         L̲i̲s̲t̲ ̲o̲f̲ ̲S̲c̲r̲e̲w̲s̲,̲ ̲W̲a̲s̲h̲e̲r̲s̲,̲ ̲a̲n̲d̲ ̲N̲u̲t̲s̲

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         DESCRIPTION MOUNTING OF:
          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         Head Screw M6 x 16
         Cup Washer for M6            Crates, 19"  Panels
         Cayed Nut M6

         Head Screw M5 x 10
         Flatwasher for M5            Ground Wires
         Springwasher for M5
         Nut M5

         Head Screw M4 x 10
         Flatwasher for M4            Power Inlet Box
         Springwasher for M4
         Nut M4

         Counter Sink Screw M3 x 16
         Springwasher for M3          V24 BPJF
         Nut M3

         All screws are the posidrive type