top - download
⟦ac5d08972⟧ Wang Wps File
Length: 2921 (0xb69)
Types: Wang Wps File
Notes: Spelunked
Names: »~ORPHAN76.00«
Derivation
└─⟦f6f93b0e6⟧ Bits:30006245 8" Wang WCS floppy, CR 0245A
└─ ⟦this⟧ »~ORPHAN76.00«
WangText
…05……00……00……00……00…L…02……00……00…L
L L…07…K…0c…I…09…I…86…1 …02… …02… …02…
…02…CPS/TCN/031
…02…SRA/811110…02……02…#
CAMPS LTUX-S V24 INTERFACES
…02……02…CAMPS
T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲
1. GENERAL................................. 4
2. INTERFACES............................. 5
2.1 LTUX-S TO VDU........................ 5
2.2 LTUX-S TO MSP........................ 8
2.3 LTUX-S TO OCR........................ 11
2.4 LTUX-S TO PTP/PTR.................... 14
2.5 LTUX-S TO TRC/POINT-TO-POINT........ 16
2.6 LTUX-S TO STATISTICAL MUX. 1......... 18
2.7 LTUX-S TO STATISTICAL MUX. 2......... 21
3. REMOTE SITE CONNECTIONS................. 24
1̲ ̲G̲E̲N̲E̲R̲A̲L̲
This TCN presents the currently existing CAMPS LTUX-S
V24 interfaces. The purpose of this presentation is
to establish:
1. the relevant V24 interface signals
2. how to interpret the V24 interface control
signals
Interface types to be described are:
LTUX-S to VDU, opto (sec. 2.1)
LTUX-S to MSP, opto (sec. 2.2)
LTUX-S to OCR (sec. 2.3)
LTUX-S to PTP/PTR (sec. 2.4, TBD)
LTUX-S to TRC/Point-to-point (sec. 2.5)
LTUX-S to Statistical Mux. 1 (sec. 2.6)
LTUX-S to Statistical Mux. 2 (sec. 2.7)
To complete the picture of CAMPS terminal connections
chapter 3 goes through connections betwee the Statistical
Multiplexer and the different terminals on the remote
site.
It should be noted that the LTUX-S V24 controlsignal
input circuit 109, as described in the TCM CSD-MIC/005/TCM/0009,
has been interchanged with circuit 107 for the CAMP
application (having LTUX-S software impact).
2̲ ̲I̲N̲T̲E̲R̲F̲A̲C̲E̲S̲
2.1 L̲T̲U̲X̲-̲S̲ ̲T̲O̲ ̲V̲D̲U̲
This interfacetype requires the following V24 circuits
(ref. fig. 2.1-1):
102 : Signal ground
103 : Transmitted data (TXD)
104 : Received data (RXD)
105 : Request To Send (RTS)
106 : Clear To Send (CTS)
107 : Data Set Ready (DSR)
108.2: Data Terminal Ready (DTR)
N̲o̲t̲e̲:̲ ̲A̲l̲l̲ ̲i̲n̲t̲e̲r̲f̲a̲c̲e̲ ̲c̲i̲r̲c̲u̲i̲t̲s̲ ̲a̲r̲e̲ ̲d̲e̲s̲c̲r̲i̲b̲e̲d̲ ̲a̲s̲ ̲s̲e̲e̲n̲
̲f̲r̲o̲m̲ t̲h̲e̲ ̲L̲T̲U̲X̲-̲S̲ ̲u̲n̲l̲e̲s̲s̲o̲t̲h̲e̲r̲w̲i̲s̲e̲ ̲i̲n̲d̲i̲c̲a̲t̲e̲d̲.̲
The LTUX-S turns …08…ON…08… D̲T̲R̲ and R̲T̲S̲ whenever it is ready
to operate.
As long as D̲S̲R̲ (activated by the VDU) is …08…OFF…08… no data
must be transmitted on T̲X̲D̲ and data received on R̲X̲D̲
must be discarded.
When the LTUX-S has data to e transmitted on T̲X̲D̲ it
must for each character to be transmitted verify that
both D̲S̲R̲ and C̲T̲S̲ is …08…ON…08…. This indicates that both the
link to the VDU (C̲T̲S̲) and the VDU (D̲S̲R̲) is ready to
operate.
If the optolink fails during transmission this is in