…00……00……00……00……00…@…0a……00……00…@…0b…@…00…@
@ ?…08…?…09…?…0e…? …86…1 …02… …02… …02…
…02…SYS/DIPA
…02…GJ/830311…02……02…#
DEMO IMPLEMENTATION PLAN ACCESS
…02…Issue 1.1…02…ACCESS
1̲ ̲ ̲S̲C̲O̲P̲E̲
Based upon the recent decision by US Airforce to come
and watch the ACCESS demonstration the Systems Division
shall prepare the demonstration according to the plan
desribed in this paper.
1.1 B̲A̲C̲K̲G̲R̲O̲U̲N̲D̲
The demonstration to be performed is outlined in document
"FLTD Manual". As it can be seen from the manual the
required scenarios are divided into mandatory (Mandatory/Evaluation)
and optional (Evaluation). e have decided to focus
on the mandatory scenarios.
The mandatory scenarios fall generally into 3 groups:
- Security
- Data Base Functions
- Recovery
In order to perform those operations we have purchased
equipment and software from 2 diferent companies:
- Britton Lee
- Relational Database Solutions (RDS)
Britton Lee delivers a backend computer (IDM) which
performs the relational database operations.
RDS delivers a set of application programs written
in PASCAL which give the user the capabilities to perform
online query operations from VDU's.
2̲ ̲ ̲H̲A̲R̲D̲W̲A̲R̲E̲ ̲C̲O̲N̲F̲I̲G̲U̲R̲A̲T̲I̲O̲N̲
The H/W configuration suggested for the demo is schematically
shown in figure 2-1. The configuration supports 4 user
stations and the database (IDM) i a dualized PU concept.
2.1 B̲A̲S̲I̲C̲ ̲H̲A̲R̲D̲W̲A̲R̲E̲
The Basic H/W is a CAMPS System which shall be integrated
and placed at RO III ground floor.
2.2 U̲S̲E̲R̲ ̲S̲T̲A̲T̲I̲O̲N̲S̲
The 4 user stations consist of:
- a VDU, Delta Data 7260T
- a MSP, Tracor 8000
2.3 T̲A̲P̲E̲ ̲S̲T̲A̲T̲I̲O̲N̲S̲
The tape station has to be borrowed/rented from another
division.
Likewise a tape controller is needed.
FIGURE 2-1…86…1 …02… …02… …02… …02…
2.4 L̲I̲N̲E̲ ̲P̲R̲I̲N̲T̲E̲R̲
The Dataproduct line printer shall be used.
2.5 I̲D̲M̲
The IDM shall be connected to the system via 4 x V24
lines connected to 1-4 LTU's. The number of LTU's dpend
upon the line speed we wish to maintain. This shall
be investigated.
2.6 H̲A̲R̲D̲W̲A̲R̲E̲ ̲B̲R̲E̲A̲K̲D̲O̲W̲N̲
A H/W Breakdown is required in order to control the
purchasing and integration efford.
3̲ ̲ ̲S̲O̲F̲T̲W̲A̲R̲E̲ ̲C̲O̲N̲F̲I̲G̲U̲R̲A̲T̲I̲O̲N̲
The S/W to be used for the emo (as seen now) is depicted
in figure 3-1. The configuration is very preliminary
and the necessary details shall be worked out.
3.1 O̲P̲E̲R̲A̲T̲I̲N̲G̲ ̲S̲Y̲S̲T̲E̲M̲
The operating system shall be DAMOS extended by COPSY.
The functions of COPSY shall be
- Lad processes
- Allocate TDX lines
- Start processes
- Send keep alive msg to SSC/WD
In addition WAMCO and CFH shall be completed.