CAMPS SITE LEVEL MAINTENANCE MANUAL
…02…Issue 1…02… CAMPS
TDX TEST PROCEDURES STEP 4000-5000 (cont'd)
STEP PROCEDURE OBSERVATION/ACTION
̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
2988A/rt …02…CPS/TCM/005
…02…KJA/830912…02……02…
CAMPS SITE LEVEL MAINTENANCE MANUAL
…02…Issue 1…02… CAMPS
4.3.3.4 T̲D̲X̲ ̲T̲e̲s̲t̲ ̲P̲r̲o̲c̲e̲d̲u̲r̲e̲s̲
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
4000 TDX TEST ENTRY
Before start of the TDX test
procedure, verify that
1.The commands typed on the Maint.Pos.VDU
are directed to the PU which
should execute the test.
2.The PU is offline
3.The PU is enabled
4.The PU is in Normal Mode
It is possible to obtain these
conditions e̲i̲t̲h̲e̲r̲
a) by commands issued from the
Maint.Pos. VDU via the Watch
Dog Subsystem
o̲r̲
b) by manual switchs settings
on the MAP module and a reconfiguration
procedure.
a.1) P̲U̲ ̲ ̲ ̲M̲a̲i̲n̲t̲.̲P̲o̲s̲.̲V̲D̲U̲ ̲c̲o̲m̲m̲u̲n̲i̲c̲a̲t̲i̲o̲n̲
̲b̲y̲ ̲t̲h̲e̲ ̲W̲D̲ ̲C̲o̲m̲m̲a̲n̲d̲
PUNno, no is No of the actual
PU (refer to section 5.76
in (*))
a.2) P̲U̲ ̲O̲F̲F̲L̲I̲N̲E̲ ̲B̲Y̲ ̲T̲H̲E̲ ̲W̲D̲ ̲c̲o̲m̲m̲a̲n̲d̲:̲
OFLI (refer to section 5.7.7
in (*))
a.3) P̲U̲ ̲e̲n̲a̲b̲l̲e̲d̲ ̲b̲y̲ ̲t̲h̲e̲ ̲W̲D̲ ̲c̲o̲m̲m̲a̲n̲d̲:̲
̲E̲N̲P̲U̲
(refer to section 5.7.4
in (*)).
a.4) P̲U̲ ̲ ̲n̲o̲r̲m̲a̲l̲ ̲m̲o̲d̲e̲ ̲t̲h̲e̲ ̲W̲D̲ ̲c̲o̲m̲m̲a̲n̲d̲:̲
̲N̲O̲R̲M̲
(refer to section 5.7.9
in (*))
(*) CAMPS MAINTENANCE POSITION
OPERATION MANUAL, Doc.No. CPS/OPM/005
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
b.1) P̲U̲ ̲ ̲M̲a̲i̲n̲t̲.̲ ̲P̲o̲s̲.̲ ̲V̲D̲U̲ ̲c̲o̲m̲m̲u̲n̲i̲c̲a̲t̲i̲o̲n̲
̲b̲y̲ ̲r̲e̲c̲o̲n̲f̲i̲g̲u̲r̲a̲t̲i̲o̲n̲:̲
It is possible to connect
the Maint.Pos.VDU directly
to the PU by a reconfiguration
procedure. The procedure
is described in step 3600
- 3700 in section 4.3.3.3.
b.2) P̲U̲ ̲O̲f̲f̲l̲i̲n̲e̲ ̲b̲y̲ ̲s̲w̲i̲t̲c̲h̲s̲e̲t̲t̲i̲n̲g̲
The PU is taken offline
by pressing the MC button
situated on the front
of the MAP module in the
actual PU (refer to section
4.5).
b.3) P̲U̲ ̲e̲n̲a̲b̲l̲e̲d̲ ̲b̲y̲ ̲s̲w̲i̲t̲c̲h̲s̲e̲t̲t̲i̲n̲g̲.̲
The PU is enabled by switching
the EN/DIS switch on the
front of the MAP module
in the actual PU to the
EN position (refer to
section 4.5)
b.4) P̲U̲ ̲ ̲N̲o̲r̲m̲ ̲M̲o̲d̲e̲ ̲b̲y̲ ̲S̲w̲i̲t̲c̲h̲s̲e̲t̲t̲i̲n̲g̲:̲
The PU is set in normal
mode by switching the
MAIN/NRM switch on the
front of the MAP module
to the NRM position (refer
to section 4.5)
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
4005 Check the o The
configuration
of
the
PU
should
be
configuration of identical to the configuration
shown
the PU by typing in Figure 4.3.3.4-1.
UM (CR) If correct, continue to step
4010
UM8 (CR)
o If the configuration is not
identical, or it is not possible
to enter the command, it indicates
an error in the PU Subsystem
or in the communication between
the PU and the Maint. Pos.
VDU. Check the VDU.
GO TO step 6000.
UM…01…Figure 4.3.3.4-1
4010 Switch the FD CTRL o The
following
output
should
appear:
to the Off-line PU
by the DISK "FFFF"
ASSIGNMENT COMMAND " "
(refer to the Maint.
Pos. Operation Manual) If correct, continue to step
4015
or
by the CUCP switch
-AEN is switched
to the Off-line PU.
Enable the FD CTRL
by typing:
IR 1A[1 (CR)
o If the expected output does
not appear then it indicates
an address error or an error
in the FD CTRL module.
GO TO step 2005.
4015 Analyze the error o If
one
or
more
of
the
following
error
situation. reports are printed out on
the maintenance
position printer:
R̲e̲p̲o̲r̲t̲ ̲I̲D̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
T̲M̲S̲ ̲[̲[̲1̲ ̲-̲ ̲T̲M̲S̲ ̲[̲[̲8̲ ̲ ̲ ̲ ̲
̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
or
an error indication in
TDX CTRL or TDX BUS STI
module
GO TO step 4100
o If one or more of the following
error reports are printed out
on the maintenance position
printer:
R̲e̲p̲o̲r̲t̲ ̲I̲D̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
TMS [[9 - TMS [13
̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
or
an error indication in
LTUX
module.
GO TO step 4300
o If one or more of the following
error reports are printed out
on the maintenance position
printer:
R̲e̲p̲o̲r̲t̲ ̲I̲D̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
PER [[1 - PER [[5
TMS [14 - TMS [18
̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
or
an error indication in
LTUX
channel.
GO TO step 4400
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * *…86…1 …02… …02… …02… …02… …02…
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
4100 Error in the STI ENTRY
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
4105 Boot the STI test o The
following
output
should
appear:
program.
A detailed step-by- "CSS/730 CR
step procedure is 80 M TDX TEST
described in section VS..."
4.7.2.1. "CPU ["
----"
Below are listed If correct, continue to step
4110
the main steps in
the procedure of
the STI test.
Before entering the
boot command, verify
that
a) The actual DISK or FD
CTRL is assigned to the
Off-Line PU
b) The actual disket-
te/disk pack is mounted
in the drive.
The FD boot command is
as follows:
F̲D̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
BA 1[[1 (CR)
BT FD5[[ (CR)
BU [ or 1 (CR)
B̲E̲ ̲(̲C̲R̲)̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
The DISK boot command is as
follows:
S̲M̲D̲ ̲D̲I̲S̲K̲ ̲ ̲ ̲ ̲ ̲
BA 1[25 (CR)
BM 14[ (CR)
B̲E̲ ̲A̲ ̲(̲C̲R̲)̲
o If the expected output does
not appear then it indicates
that it is not possible to
boot the test program from
that floppy drive or disk drive.
Boot the STI test program using
the other drive.
If it is still possible to
boot the test program, it indicates
an error in communication between
the channel unit and the processor
unit.
GO TO step 2005.
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
4110 It is now possible to o Examine
the
output
from
the
test
start the test program program in order to verify
if the
A detailed step-by- program detected any errors.
step procedure is
described in section The error codes and an example
of a
4.7.2.1. successful print out
is shown in section 4.7.2.2.
The test time is app. 20 sec.
If correct, continue to step
4210
The start command is:
DO STI ̲TEST (CR).
o If the test program detected
an error, it indicates a possible
error in the STI. Analyze the
error code or
Check power LED in STI
Remove the TIA modules
Repeat step 4110
If the error is cleared then
it indicates an error in one
of the removed TIA.
Replace the TIA modules
one by one.
Verify the PU Subsystem
GO TO step 1900
If the error is not cleared,
then
Replace the STI (refer
to Section 4.4)
Repeat step 4110.
If the error is not cleared,
it indicates an error in the
PU crate.
Check the PU crate
GO TO step 1800.
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
4210 It is now possible to o Examine
the
output
from
the
test
start the TDX-BUS program in order to verify
if the
test program program detected any errors.
A detailed step-by-
step procedure is The error codes and an example
of a
described in section successful print out
4.7.2.1. is shown in section 4.7.2.2.
Below is listed the The test time is app. 20 sec.
main step in the
start procedure of If correct, verify the TDX
crate
the TDX-BUS test
program.
GO TO step 4900
The start command is:
DO TDX ̲BUS (CR)
o If the test program detected
an error in the TDX ̲BUS test
then
GO TO step 4215
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
4215 Open the doors o Check
that
the
power
LEDs
are
"ON"
in
to the TDX crate# ̲ the following modules:
- Power Supply
- TDX CTRL# ̲
Check FAN
Check the cables connected
to the TDX CTRL # ̲
Check the cables connected
to the TIA in the Off-line
PU
Check the connections and cables
on the TDX BUS.
Check the TDX Bus Termination
Resistor
(refer to the Assembly Breakdown
Doc.No. CPS/SDS/017).
If correct, continue to step
4220.
o If the TDX CTRL# ̲ power LED
is "OFF", it indicates an error
in the TDX CTRL# ̲ module.
Replace the TDX CTRL#
̲ module
(refer to Section 4.4)
(Check the fuse)
Repeat step 4215.
If the power LED is still "OFF",
it indicates an error in the
TDX crate.
Check the TDX crate #
̲ (refer to section 4.4)
GO TO step 4800
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
4220 Execute TDX o If
no
errors
are
detected
CTRL# ̲"STATUS TEST"
Continue to step 4225.
The setup and o If an error is detected then
steps in the
STATUS TEST Replace TDX CTRL# ̲ (refer
to
procedure is Section 4.4)
shown in figure Repeat step 4220.
4.3.3.4-2
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
4225 Start the TDX ̲BUS o Examine
the
output
from
the
test
test program. program in order to verify
if the
A detailed step-by- program detected any errors.
step procedure is
described in The error codes and an example
of a
section 4.7.2.1. successful printout
is shown in section 4.7.2.2.
The test time is app. 20 sec.
If correct; verify the TDX
crate # ̲
GO TO step 4900.
TDX Status Test…01…Figure 4.3.3.4-2
The start command
is:
DO TDX ̲BUS (CR)
o If the test program detected
an error, it indicates an error
in the transmission between
the STI in the offline PU and
the TDX CTRL# ̲. Analyze the
error or
Interchange TIA#1 with
TIA#2 in the offline PU
(refer to Section 4.4)
Repeat step 4225.
If the error is not cleared,
it indicates an error in the
TDX outlet# ̲ (connected to
TIA#1 in the offline PU) TDX
outlet# ̲ (connected to TDX
CTRL# ̲) or the TDX outlets
connected to the TIA in the
online PU.
Check the three TDX outlets
(refer to step 4800).
If the error is still not cleared,
it indicates an error in the
TDX CTRL# ̲ or in the TDX crate#
̲.
Replace TDX CTRL# ̲ (refer
to Section 4.4.)
Repeat step 4225
If there is still an error,
it is necessary to check the
TDX crate.
Check TDX crate# ̲
GO TO step 4800.
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
4300 Error in the LTUX ENTRY
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
4305 Boot the TDX o The
following
output
should
appear:
test program.
A detailed step-by- "CSS/730 CR
step procedure is 80 M TDX TEST
described in section VS..."
4.7.2.1. "CPU ["
"-- "
If correct, continue to step
4310
Below are listed
the main steps in
the procedure of
the TDX test.
Before entering the
boot command, verify
that
a) The actual DISK or FD
CTRL is assigned to the
Off-Line PU
b) The actual diskette/
disk pack is mounted
in the drive.
The FD boot command is
as follows:
F̲D̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
BA 1[[1 (CR)
BT FD5[[ (CR)
BU [ or BU 1 (CR)
B̲E̲ ̲(̲C̲R̲)̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
The DISK boot command
is as follows:
S̲M̲D̲ ̲D̲I̲S̲K̲ ̲ ̲ ̲ ̲ ̲ ̲
BA 1[25 (CR)
BM 14[ (CR)
B̲E̲ ̲A̲ ̲(̲C̲R̲)̲ ̲ ̲ ̲ ̲ ̲
…86…1 …02… …02… …02… …02… …02…
o If the expected output does
not appear then it indicates
that it is not possible to
boot the test program from
that floppy drive or disk drive.
Boot the TDX test program using
the other drive.
If it is still not possible
to boot the test program, it
indicates an error in communication
between the channel unit and
the processor unit.
GO TO step 2005.
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
4310 Enable the BSM-X o Examine
the
output
from
the
test
situated in the same program in order to verify
if the
TDX crate as the program detected any errors.
LTUX # ̲ to the Off-
line TDX BUS in the The error codes and an example
of a
following way: successful print out
is shown in section 4.7.2.2.
a) Users connected The test time is app. 30 sec.
to the TDX Crate
must be requested to If correct,
cease operation.
GO TO step 4320.
b) When all users
connected to the TDX-
Crate have ceased
operation, the BSM-X
is disabled from the
On-line TDX BUS,
eitherby the BSM-X
Controlcommand (refer
to the Pos.
Operation Manual)
or
by the
BUS1/BUS2 switch
situated on the front
of the BSM-X module.
It is now possible to
start the program
A detailed step-by-
step procedure is
described in section
4.7.2.1.
Below are listed
the main steps in
the start procedure
of the tests.
Before entering the
start command verify
that
a) The parameter "no"
in the start command is
correct (refer to
section 4.7.2.1)
When the "---"
appears then it is
possible to enter
a new command
The start command is:
DO STI ̲TEST (CR)
DO TDX ̲BUS (CR)
DO LTUX ̲STATUSno (CR).
o If the STI test program detected
an eror then it indicates a
possible error in the STI.
Analyze the error code or
Check power LED in STI
and
Remove the TIA modules.
Repeat step 4310
If the error is cleared then
it indicates an error in the
removed TIA modules.
Replace the TIA modules
one by one.
Verify the TDX Subsystem.
Go to step 4900.
If the error is not cleared
then
Replace the STI
Repeat step 4310
If the error is still not cleared
Check the PU crate, go
to step 1800
o If the TDX ̲BUS test program
detected
an error then it indicates
an
error in the TDX CTRL, outlets
or
TDX ̲BUS. Analyze the error
or
GO TO step 4215
o If the LTUX ̲STATUS test program
detected an error then it indicates
a possible error in the LTUX-S
module
Check the LEDs in the
modules in the actual
TDX crate.
o If the LEDs in both LTUX-Ss
are as follows:
TDS.ST on
then it indicates an error
in the BSM-X, TDX outlet or
cable between the TDX outlet
and the BSM-X back panel.
Go to step 4315
o If there is no error indication
in the tested LTUX-S module,
then it indicates an internal
error in the LTUX-S module.
Replace LTUX-S module
Repeat step 4310
If the error is not cleared,
then it is necessary to verify
that it is possible to execute
a test in the other LTUX-S
module situated in the same
crate.
Go to step 4315
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * *
4315 Execute the LTUX o Examine
the
output
from
the
test
STATUS test program. program in order to verify
if the
A detailed step-by- program detected any errors.
step procedure is
described in The error codes and an example
of a
section 4.7.2.1. successful printout
is shown in section 4.7.2.2.
Below is listed the The test time is app.30 sec.
main step in the
start procedure of If correct, then the error
has
the LTUX ̲STATUS disappeared.
test.
Before entering the start command, verify that
The parameter x is the No of TDX crate which the error
reported LTUX-S is mounted.
The start command is:
DO LTUX ̲STATUS1x (CR)
DO LTUX ̲STATUS2x (CR)o If the test program detected
an error in only one LTUX-S
module then it indicates an
error in the TDX crate
Go to step 4800
o If the test program detected
an error in both, it indicates
that it is not possible to
access the two LTUX # ̲ modules
situated in the TDX crate #
̲.
It is, therefore, indicated
that the error must be situated
in the BSM-X module, the outlet
connecting the BSM-X module
to the TDX BUS, or the TDX
crate.
Check the cables connecting
the BSM-X to the TDX outlet.
Check the TDX outlet connecting
the TDX CRATE to the TDX
BUS (refer to step 4700)
Repeat step 4315.
If the error is still not cleared,
it indicates that the error
must be situated in the BSM-X
module or in the TDX crate.
Replace the BSM-X
Repeat step 4315
If the error is still not cleared
Check the TDX crate #
̲
GO TO step 4800.
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * *
4320 Analyze the situation o If
the
test
described
in
step
4300
-
4320
has
already
been
executed
by
the
dual
PU
then
the
error
has
disappeared.
Note
the
error
indication
and
Verify the TDX crate
GO TO step 4900
o If the test not yet has been
executed by the dual PU, then
the test should be repeated
by the dual PU
Execute a controlled
SWITCHOVER (refer to the
Maintenance Position Manual
Doc. No. CPS/OPM/005)
and then GO TO step 4000
o If the test described in 4300
- 4320 has been executed from
both PUs and a fault has been
diagnosed and cleared then
Verify the TDX crate
GO TO step 4900
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
4400 Error in a channel ENTRY
in the LTUX module
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
4405 Boot the TDX The
following
output
should
appear:
test program.
A detailed step-by- "CSS/730 CR
step procedure is 80 M TDX TEST
described in section VS..."
4.7.2.1. "CPU ["
"-- "
Below are listed
the main steps in If correct, continue to step
4410
the procedure of
the TDX test.
Before entering the
boot command, verify
that
a) The actual DISK or FD
CTRL is assigned to the
Off-Line PU
b) The actual disk
pack diskette is mounted
in the drive.
The FD boot command is
as follows:
F̲D̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
BA 1[[1 (CR)
BT FD5[[ (CR)
BU [ or 1 (CR)
B̲E̲ ̲(̲C̲R̲)̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
The DISK boot command
is as follows:
S̲M̲D̲ ̲D̲I̲S̲K̲ ̲ ̲ ̲ ̲ ̲ ̲
BA 1[25 (CR)
BM 14[ (CR)
B̲E̲ ̲A̲ ̲(̲C̲R̲)̲
o If the expected output does
not appear then it indicates
that it is not possible to
boot the test program from
that disk drive or floppy drive.
Boot the TDX test program using
the other drive.
If it is still not possible
to boot the test program, it
indicates an error in the communication
between the channel unit and
the processor unit.
GO TO step 2005.
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
4410 Enable the BSM-X module
o Examine
the
output
from
the
test
to the Off-line TDX BUS program in order to verify
if the
in the following way: program detected any errors.
(if MSP: check that 60
lines are
a) Users connected to printed on the MSP)
the BSM-X situated in
the same TDX crate The error codes and an
example of
as the LTUX module a successful print must
be
requested out
is
shown
in
section
4.7.2.2.
to cease operation.
The test time is app.
1 min.
b) When the users
connected to the BSM-X If correct, then the
following
have ceased operation, situation should be considered:
the BSM-X is
disabled from the On- - If the type of the peripheral
line TDX BUS either is VDU, then
by the BSM-X control
command - (refer to GO TO step 4415
the Maint. Pos.
Operation Manual) or -If PTP/R or MSP verify
the TDX
by the BUS1/BUS2 Subsystem
switch situated on GO TO step 4900
the front of the
BSM-X module.
It is now possible to
start the TDX ̲LTUX
test program
A detailed step-by-
step procedure is
described in section
4.7.2.1.
Below are listed the
main steps in the
start procedure of
the TDX ̲LTUX test.
Before entering the
start command, verify
that
The parameter "no" amd
"type" in the start
command is correct.
(Refer to
Section 4.7.2.1)
When the "----" appears,
it is possible to enter
a new command.
The start command is:
DO OPENno (CR)
DO type (CR)
DO CLOSEno (CR)
o If the test program detected
an error, it indicates that
there is an error in the LTUX
module or in the distribution
equipment. Analyze the error
code or
GO TO step 4420.
4415 Execute an offline o The
following
output
should
appear
test of the keyboard on the VDU connected to the
LTUX
on the VDU connected channel after app. 20 sec:
to the LTUX channel.
A detailed step-by- "PLEASE TYPE SOME DATA"
step procedure is " ̲ ̲"
in section
4.7.2.1.
The parameter "no" is It is now possible to type
data via
identically to the the keyboard on the VDU. The
data
parameter used in is transmitted when the ENTER
key
step 4410. is pressed. The data is echoed
to
the Maint.Pos.VDU.
The start command
is: If the echoed data should be
identically
to the typed data then no errors
are
DO TDX ̲VDU ̲IOno (CR) are detected.
If correct, verify the TDX
crate
GO TO step 4900
o If it is not possible to type
data on the VDU or the data
is not echoed, then it indicates
an error in the VDU connected
to the LTUX channel. Analyze
the error code or
Replace the VDU
Repeat Step 4415
and troubleshoot the VDU when
the system is operating (refer
to step 6100).
4420 It is now possible to o Examine
the
output
from
the
test
start the TDX ̲LOOP program in order to verify if
the
test programA de program detected any errors.
tailed step-by-step
procedure is The error codes and an example
of a
described in section successful print out
4.7.2.1. is shown in section 4.7.2.2.
Below are listed the The test time is app. 10 sec.
main steps in the
start procedure of If correct, it indicates an
error
the TDX ̲LOOP test. within the Distribution Equipment.
GO TO step 5010.
Before entering the
start command, verify
that
a) The BSM-X is assigned
to the Off-line TDX
BUS.
b) The LTUX channel
is enabled.
c) The V24 Loop Back
Adapter is connected
to the actual channel
of the LTUX via a V24
monitoring module
(refer to figure
4.3.3.4-3)
d) The parameter "no"
in the start command
is correct.
The start command is:
DO TDX ̲LOOPno (CR).
o If the test program detected
an error, it indicates that
there is an error in the LTUX
# ̲module. Analyze the error
or
GO TO step 4310
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
(1): V24 Loopback Adaptor +
V24 Monitoring Module
V24 Mon Test of
Module Ch1-4
S̲l̲o̲t̲ ̲N̲o̲.̲ ̲ ̲ ̲ ̲ ̲ ̲S̲l̲o̲t̲ ̲N̲o̲.̲
5, 6 10-7
13, 14 18-15
̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
NOTE: The actual L/L Adaptor/
OPTO Module must be removed before running
Loopback test using V24 Monitoring Module
and V24 Loopback Adaptor
(2) V24 Loopback Adaptor
(3) OPTO Loopback Cable
LTUX-S Loopback Test.
Figure 4.3.3.4-3
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
4700 TDX Outlet Check ENTRY
Procedure
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
4705 This step contains o The
following
output
should
appear
a test of the out- on the VDU:
lets, BSM-X LTUX-S
module connected
to a TDX Ctrl. "LTUX NO ready/failing"
The Test Setup is (No is the decimal number of
the
shown in figure LTUX-S I/O adr)
4.3.3.4-4.
The status of out-
lets and LTUX-S is The LTUX is "ready" if it is
connected
provided by typing: to the TDX-BUS.
S on the VDU.
The number of
LTUX-S's The LTUX is "failing" if it
is not
connected to connected to the TDX BUS.
the TDX-BUS is
displayed on the
VDU screen.
If 2 LTUX-Ss is mounted in
the same TDX crate and connected
to the TDX-BUS are "failing"
then it indicates an error
in either the TDX outlet, BSM-X,
the BSM-X-outlet cable or the
TDX crate.
Check that the BSM-X-Outlet
cable is in proper condition.
Replace the outlet
(refer to figure 4.3.34-4)
If there is still error then
Change the BSM-X
Repeat step 4705
If there is still an error
then check the TDX crate.
GO TO step 4800
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
The Setup is shown in Figure 4.3.3.4-2.
The input/output of the test is described in step 4705.
The outlets connected to TDX crates and TDX BUS No.
1 and TDX BUS No. 2 are identified below.
Figure 4.3.3.4-4
TDX Outlet Test Setup…86…1 …02… …02… …02… …02… …02…
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
4800 TDX Crate Check ENTRY
Procedure
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
4805 Check that o If the power level
measured in the
TDX
the voltage crate motherboard
is not correct,
then
level in the
TDX crate is as a)Check
(and
replace)
the
fuses
shown in figure situated
on
the
front
of
the
power
4.3.3.4-5, 6. supplies.
b)If there is still an error, check the input
to the actual power
supply (refer to figure 4.3.3.4-5).
If there is any error in the input to
the power supply then check and correct the
error.
The power distribution diagrams are shown in
the Assembly Breakdown (refer to Doc.No. CPS/SDS/017).
c)If the power level measured in the TDX Crate
is not correct then
Replace the power supply
(refer to section 4.4)
d)If the power level is still not correct then
the error must be within the TDX crate.
GO TO step 4810
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
Figure 4.3.3.4-5
TDX Crate - Mains Voltage Level
Figure 4.3.3.4-6
TDX Crate - Adaptor Voltage Level
4810 TDX Crate Test o This
test
describes
the
test
of
the
Procedure TDX crate.
a) Check that the cables are
connected properly to the modules
and there is no damage on the
modules.
b) Remove all front modules
from the TDX crate.
c) Check all female connectors
on the motherboard.
d) Check that all the internal
cables are connected properly.
e) Check that it is possible
to seat the modules properly
in the TDX crate.
If any errors are detected
then correct them or replace
the failing module.
f) Insert the modules in the
rack, seat the modules and
connect the cables (refer to
section 4.4).
g) Verify the TDX Subsystem
GO TO step 4900
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
4900 TDX Crate Verification ENTRY
Test Procedure
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
4905 It is necessary to verify
that the original error
indication is deleted
before the troubleshooting
procedure is finished,
therefore:
1) GO TO the original ENTRY
POINT in the Off-line
Troubleshooting Tree (defined
by the System Troubleshooting
Tree).
2) Verify that it is possible
to execute the described
step-by- step procedures
without detecting any
errors.
3) If no errors are detected
the troubleshooting of
the TDX Subsystem is finished.
4) Complete failure report
and logbook (refer to
section 6)