!…00……00……00……00…G…02……00……00…G
G…05…G…07…F…0f…D…09…D…0c…D…0d…D…01…D…02…D…05……86…1 …02… …02… …02…
3100A/…02…FIX/1161/PSP/0047
…02…FMK/861217…02……02…
FIKS EVA Subsystem PSP
…02…HFJ/821201…02… FIKS
FIKS EVA Subsystem PSP
FIX/1161/PSP/0047
FIKS FMK Programmer
J]rgen H]g
FMK (6), APE, JJJ, AI, SL, NMN, LU
…0e… FIKS Pgm. Mgr. 861217
Conf. Mgr. 861217
1.1
861217
…0f…
3100A…02… FIX/1161/PSP/0047
…02… FMK/861217…02……02… ii
FIKS EVA Subsystem PSP
…02… HFJ/821201…02… FIKS
1 821201 All First Issue of Document
1.1 861217 DCN1 Changed in accordance
with Order No. 10/86.
3100A…02… FIX/1161/PSP/0047
…02… HFJ/821201…02……02… iii
EVA Subsystem PSP
…02……02… FK 7809
T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲
1 SCOPE ..........................................
1
1.1 Introduction ...............................
1
1.2 Abbreviations ..............................
1
2 APPLICABLE DOCUMENTS ...........................
2
3 MODULE SPECIFICATION ...........................
3
3.1 Functional Capabilities ....................
4
3.1.1 Introduction ...........................
4
3.1.2 EVA Processing Flow ....................
6
3.2 Interface Description ......................
7
3.3 Processing .................................
9
3.4 Data Organization ..........................
11
3.4.1 TABLE:REGISTRATION COMMAND TABLE .........
11
3.4.1.1 MESSAGE TYPE TABLE (MTT) LAY .......
12
3.4.1.2 SUB-CATEGORY TABLE (SCT) LAY .......
12
3.4.1.3 EVENT TABLE (ETA) LAYOUT ............
13
3.4.2 RCT Description ........................
14
3.4.3 Registration Command Table Contents ....
17
3.5 Storage Allocation .........................
27
3.6 Performance Characteristics ................
28
3.7 Limitations ................................
29
3.8 Error Codes/Error Locations ................
30
3.8.1 Error Codes ............................
30
3.8.2 Error Locations ........................
30
3.9 Listing References .........................
31
4 QUALITY ASSURANCE ..............................
32
4.1 Qualification Tests ........................
32
5 PREPARATIONS FOR DELIVERY ......................
33
1 S̲C̲O̲P̲E̲
1.1 I̲n̲t̲r̲o̲d̲u̲c̲t̲i̲o̲n̲
The purpose of this document is to describe the function of the EVA-process.
1.2 A̲b̲b̲r̲e̲v̲i̲a̲t̲i̲o̲n̲s̲
Please refer to FIKS DATA INTERFACE FIX/0100/MAN/0004.
2 A̲P̲P̲L̲I̲C̲A̲B̲L̲E̲ ̲D̲O̲C̲U̲M̲E̲N̲T̲S̲
1. REQUIREMENTS SPECIFICATION
FIX/0000/SPC/0002
Vol. I - III
2. FIKS SYSTEM DESIGN SPECIFICATION
FIX/1000/DSP/0001
3. FIKS SOFTWARE INTERFACE REFERENCE
FIX/0100/MAN/0003
4. FIKS DATA INTERFACE REFERENCE
FIX/0100/MAN/0004
5. SUPPORT SOFTWARE DESIGN SPEC.
FIX/1103/DSP/0009
6. CR 80 AMOS KERNEL
CSS/302/PSP/0008
7. CR 80 AMOS, I/O SYSTEM
CSS/006/PSP/0006
3 M̲O̲D̲U̲L̲E̲ ̲S̲P̲E̲C̲I̲F̲I̲C̲A̲T̲I̲O̲N̲
3.1 F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲C̲a̲p̲a̲b̲i̲l̲i̲t̲i̲e̲s̲
3.1.1 I̲n̲t̲r̲o̲d̲u̲c̲t̲i̲o̲n̲
As shown in Figure 3.1.1., the EVR module consists of three processes and two tables. The
Event Analysis Process (EVA) reads one EPM from the EV queue at a time and by look-up in
the Registration Command Table (RCT), it performs one or more of the following actions:
o Queue EPM in LOG queue
o Send message to Network Display Process (NED)
o Queue EPM in OU queue
The Network Display Process (NEDP) will, each time it receives a message, read the changed
data from FST and update the FIKS Display Table (FDT) to describe the new image for the color
-TV display
Finally, the NEDP outputs the changed part of the image to the color -TV and activates the
alarm horn if so specified in the message.
Figure 3.1.1-1, EVR Break Down
3.1.2 E̲V̲A̲ ̲p̲r̲o̲c̲e̲s̲s̲i̲n̲g̲ ̲f̲l̲o̲w̲
The EVA process receives all Event Pseudo Messages (EPM's) from the EV queue.
Based upon look-up in internal registration command tables (using EPM as look-up key), the
EVA will effectuate one or more of the following functions:
A: Requeue the received EPM in the LOG queue for logging.
B: Requeue the received EPM in the OU queue for generation of an outgoing network control
message.
C: Send an AMOS message to the Network Display Process (NEDP) for the purpose of updating
the network display on the color-TV and/or sounding the alarm horn.
3.2 I̲n̲t̲e̲r̲f̲a̲c̲e̲ ̲D̲e̲s̲c̲r̲i̲p̲t̲i̲o̲n̲
The format of the AMOS letter, sent from EVAP to NEDP is shown in Figure 3.2-1.
The parameters ID and TRUNK are copied directly from the EPM.
The RECM item is the registration command, read from RCT.
message type = NEDPC for NEDP command letter
Figure 3.2-1, Format of AMOS Message to : NEDP
For further description please refer to chapter 3.1
3.3 P̲r̲o̲c̲e̲s̲s̲i̲n̲g̲
The EVA will, for each EPM in the EV queue, perform the following execution:
o Read EVENT-ID from EPM
o By look-up, as shown in Figure 3.3-1, retrieve a Registration Command (RECM) to be used
for all further processing.
o Analyse the RECM and process as follows:
- RECM (LOG):
queue the EPM read from the EV queue into the LOG queue
RECM (DISP):
prepare and send an AMOS message to NEDP (see format i Chapter 3.2)
RECM (OUT):
queue the EPM read from the EV queue into the OU queue
RECM (SH):
search in a Special Handling action address table for an entry, identified by
the EVENT-ID (read from EPM). Jump to the action routine, specified next to the
EVENT-ID.
Fig. 3.3-1
3.4 D̲a̲t̲a̲ ̲O̲r̲g̲a̲n̲i̲z̲a̲t̲i̲o̲n̲
3.4.1 T̲A̲B̲L̲E̲:̲R̲E̲G̲I̲S̲T̲R̲A̲T̲I̲O̲N̲ ̲C̲O̲M̲M̲A̲N̲D̲ ̲T̲A̲B̲L̲E̲
3.4.1.1 M̲E̲S̲S̲A̲G̲E̲ ̲T̲Y̲P̲E̲ ̲T̲A̲B̲L̲E̲ ̲(̲M̲T̲T̲)̲ ̲L̲A̲Y̲O̲U̲T̲
3.4.1.2 S̲U̲B̲-̲C̲A̲T̲E̲G̲O̲R̲Y̲ ̲T̲A̲B̲L̲E̲ ̲(̲S̲C̲T̲)̲ ̲L̲A̲Y̲O̲U̲T̲
3.4.1.3 E̲V̲E̲N̲T̲ ̲T̲A̲B̲L̲E̲ ̲(̲E̲T̲A̲)̲ ̲L̲A̲Y̲O̲U̲T̲
3.4.2 R̲C̲T̲ ̲D̲e̲s̲c̲r̲i̲p̲t̲i̲o̲n̲
D̲A̲T̲A̲ ̲D̲E̲S̲C̲R̲I̲P̲T̲I̲O̲N̲ ̲F̲O̲R̲ ̲T̲A̲B̲L̲E̲:̲ ̲R̲C̲T̲
R̲E̲G̲I̲S̲T̲R̲A̲T̲I̲O̲N̲ ̲C̲O̲M̲M̲A̲N̲D̲ ̲T̲A̲B̲L̲E̲
D̲A̲T̲A̲ ̲D̲E̲S̲C̲R̲I̲P̲T̲I̲O̲N̲ ̲F̲O̲R̲ ̲T̲A̲B̲L̲E̲:̲ ̲R̲C̲T̲
3.4.3 R̲e̲g̲i̲s̲t̲r̲a̲t̲i̲o̲n̲ ̲C̲o̲m̲m̲a̲n̲d̲ ̲T̲a̲b̲l̲e̲ ̲C̲o̲n̲t̲e̲n̲t̲s̲
S̲p̲e̲c̲i̲a̲l̲ ̲H̲a̲n̲d̲l̲i̲n̲g̲
MSA, SSNR :
MSA, SSNC : ALARM only if change to failure mode
MTE, TEDI : ALARM only if disconnect after harderror
MTE, TECT : ALARM only if closed after harderror
mte, TEOP : ALARM only if: NPDN ON/OFF
THRESHOLD ON/OFF
E̲V̲E̲N̲T̲ ̲I̲N̲T̲E̲R̲P̲R̲E̲T̲A̲T̲I̲O̲N̲:̲ ̲M̲E̲S̲S̲A̲G̲E̲ ̲-̲ ̲1̲ ̲(̲T̲Y̲M̲E̲)̲
E̲V̲E̲N̲T̲ ̲I̲N̲T̲E̲R̲P̲R̲E̲T̲A̲T̲I̲O̲N̲:̲ ̲M̲E̲S̲S̲A̲G̲E̲ ̲-̲2̲(̲T̲Y̲M̲E̲)̲
E̲V̲E̲N̲T̲ ̲I̲N̲T̲E̲R̲P̲R̲E̲T̲A̲T̲I̲O̲N̲:̲ ̲M̲E̲S̲S̲A̲G̲E̲ ̲-̲ ̲3̲ ̲(̲T̲Y̲M̲E̲)̲
E̲V̲E̲N̲T̲ ̲I̲N̲T̲E̲R̲P̲R̲E̲T̲A̲T̲I̲O̲N̲:̲ ̲C̲O̲M̲M̲A̲N̲D̲ ̲-̲ ̲1̲(̲T̲Y̲L̲E̲)̲
E̲V̲E̲N̲T̲ ̲I̲N̲T̲E̲R̲P̲R̲E̲T̲A̲T̲I̲O̲N̲:̲ ̲C̲O̲M̲M̲A̲N̲D̲ ̲-̲2̲(̲T̲Y̲L̲E̲)̲
E̲V̲E̲N̲T̲ ̲I̲N̲T̲E̲R̲P̲R̲E̲T̲A̲T̲I̲O̲N̲:̲ ̲S̲T̲A̲T̲I̲S̲T̲I̲C̲S̲ ̲(̲T̲Y̲S̲T̲)̲
E̲V̲E̲N̲T̲ ̲I̲N̲T̲E̲R̲P̲R̲E̲T̲A̲T̲I̲O̲N̲:̲ ̲R̲O̲U̲T̲I̲N̲G̲ ̲(̲T̲Y̲R̲C̲)̲
E̲V̲E̲N̲T̲ ̲I̲N̲T̲E̲R̲P̲R̲E̲T̲A̲T̲I̲O̲N̲:̲ ̲T̲I̲M̲E̲ ̲-̲1̲ ̲(̲T̲Y̲T̲E̲)̲
3.5 S̲t̲o̲r̲a̲g̲e̲ ̲A̲l̲l̲o̲c̲a̲t̲i̲o̲n̲
N/A
3.6 P̲e̲r̲f̲o̲r̲m̲a̲n̲c̲e̲ ̲C̲h̲a̲r̲a̲c̲t̲e̲r̲i̲s̲t̲i̲c̲s̲
N/A
3.7 L̲i̲m̲i̲t̲a̲t̲i̲o̲n̲s̲
None
3.8 E̲r̲r̲o̲r̲ ̲C̲o̲d̲e̲s̲/̲E̲r̲r̲o̲r̲ ̲L̲o̲c̲a̲t̲i̲o̲n̲s̲
3.8.1 E̲r̲r̲o̲r̲ ̲C̲o̲d̲e̲s̲
Possible Error Codes from the EVA-process will be MTCB- and QACCESS-monitor returned Error
Codes, please refer to PSP for further details.
3.8.2 E̲r̲r̲o̲r̲ ̲L̲o̲c̲a̲t̲i̲o̲n̲s̲
Error Locations from EVA-process are as follows:
Call: Error Location:
MTCBINIT 1
QACCESS, read element 2
MTCB, read 3
QACCESS, insert element (LOG-Q) 4
QACCESS, insert element (OU-Q) 5
QACCESS, delete element 6
3.9 L̲i̲s̲t̲i̲n̲g̲ ̲R̲e̲f̲e̲r̲e̲n̲c̲e̲s̲
Please refer to SCCLDD and s/w library FIXLIB.
4 Q̲U̲A̲L̲I̲T̲Y̲ ̲A̲S̲S̲U̲R̲A̲N̲C̲E̲
4.1 Q̲u̲a̲l̲i̲f̲i̲c̲a̲t̲i̲o̲n̲ ̲T̲e̲s̲t̲s̲
Please refer to System Test Report S030-S090
5 P̲R̲E̲P̲A̲R̲A̲T̲I̲O̲N̲S̲ ̲F̲O̲R̲ ̲D̲E̲L̲I̲V̲E̲R̲Y̲
Please refer to SCCLDD