DataMuseum.dk

Presents historical artifacts from the history of:

CR80 Wang WCS documentation floppies

This is an automatic "excavation" of a thematic subset of
artifacts from Datamuseum.dk's BitArchive.

See our Wiki for more about CR80 Wang WCS documentation floppies

Excavated with: AutoArchaeologist - Free & Open Source Software.


top - download

⟦bc4dfe90b⟧ Wang Wps File

    Length: 1939 (0x793)
    Types: Wang Wps File
    Notes: Spelunked
    Names: »~ORPHAN06.00«

Derivation

└─⟦27ec2f823⟧ Bits:30006056 8" Wang WCS floppy, CR 0088A
    └─ ⟦this⟧ »~ORPHAN06.00« 

WangText



         This structure allows to

         -   Use the same TESTER in various tests with the same
             or with different test data

         -   Specify dynamic load and execution of TESTERS

         -   Execute in paralll TESTERS with internal synchronization

         -   Record output data from each pass (to be deleted
             after proper verification)

         The Test Monitor controls only the configuration and
         execution of tests, the logical contents of the tests
         resides fully withi the TESTERS and the test data.

         The Test Monitor controls the tests in this rather
         rigid manner in order to be able to trace the result
         after execution of a test.

         Tests may be fully automatic or interactive/automatic.

         It is possible interactiely to specify test steps to
         be executed and it is possible to select parts of the
         automatic sequences.

         Tests may run on disk-file input/output only or may
         include interactive input and operator verification
         of output.

         In order to allow complet documentation of tests desired
         input, expected output is presented for the operator
         by the TESTERS when interactive tests are conducted.

         The TESTDEFinition consists of control commands for
         sequences. This includes commands for load of testers
         an execution of sequences (parallel or in chain).

         Sequences define execution of steps for one Tester
         (each Tester is subdivided into subtests executed in
         steps) and synchronization of sequences (signal to
         other sequence, wait for other sequence).


         Testers, test data, and test results are kept in 3
         levels of libraries corresponding to individual responsibility,
         development team responsibility and under configuration
         control.This corresponds to the levels of control on
         the software (figure 4.5.2.1-2) and allows a controlled
         execution of operational test, because the test procedure
         is approved and under configuration control.