DSMT (PROTOTYPE)
 HARDWARE
 TEST SPECIFICATION
AND PROCEDURES…02…ISSUE
 1…02…CAMPS








3.7.4.2  T̲e̲s̲t̲ ̲P̲r̲o̲c̲e̲d̲u̲r̲e̲ ̲2̲

         This testprocedure serves to verify functional capabilities
         of PU#2, the associated part of the CU and the connected
         TDX#2 system as identified in the VCRI. The DSMT configuration
         under test is given in appendix A.



3.7.4.2.1    T̲e̲s̲t̲ ̲S̲e̲t̲ ̲U̲p̲

         One copy of the documents mentioned in sec 3.7.3 must
         be present in the testroom. 

         The test is performed via an Operator Console (OC)
         which is a printer and keyboard.

         The OC is connected to the system as follows:

             1.  Substitute the leftmost OPTO transceiver in
                 the rack C Adapter crate with a V24/V28(L/L)
                 adapter (1 channel), and connect the OC to
                 the V24 connector on the front panel of the
                 adaptor.

             2.  Remove the two V24 cables from J2 and J3 located
                 on the front panel of the WCA (rear crate of
                 the Watchdog Processor crate).

             3.  Connect the two V24 cables.

         The OC is now connected to the V24 port on the MIA
         in the rear crate of PU#2 (ref. fig. 3.7.4.2.1-1).

         Carry out/control the following:

         a)  OC Set up:

             The communication part of the OC is set to:

             1)  Asynchronous communication
             2)  7 bit character length
             3)  Even parity check/generation
             4)  1 stop bit
             5)  1200 Baud communication speed
















































                    FIGURE 3.7.4.2.1-1

            C̲o̲n̲n̲e̲c̲t̲i̲o̲n̲ ̲o̲f̲ ̲t̲h̲e̲ ̲O̲p̲e̲r̲a̲t̲o̲r̲ ̲C̲o̲n̲s̲o̲l̲e̲



         b)  Switch settings in PU#1 and PU#2 front crate modules:

             1)  The NRM/MAIN switch on the MAP module front
                 panel is set to NRM.

             2)  The EN/DIS switch on the MAP module front panel
                 is set to EN.

             3)  The host number switch (S1) on the PU#2 STI
                 is set to #01 as follows:

                 S1,4 : CLOSED
                 S1,3 : CLOSED
                 S1,2 : CLOSED
                 S1,1 : OPEN

         c)  Switch settings in PU#1 and PU#2 rear crate modules:

             1)  The Baudrate select switches 1-4 (S1) on the
                 MAP Interface Adapter (MIA) Printed Circuit
                 Board (PCB) is set to #7 which corresponds
                 to a transmission speed of 1200 Baud:

                 Switch 1:  OPEN
                 Switch 2:  OPEN
                 Switch 3:  OPEN
                 Switch 4:  CLOSED

             2)  The EN/DIS switch on the Configuration Control
                 Adaptor (CCA) front panel is set to DIS.

         d)  Switch settings in CU front crate modules:

             1)  Switches on the Channel Unit Control Panel
                 (CUCP) front panel is set as:

                 a)  The CU Bus A Switch DIS/AUTO is set to
                     AUTO

                 b)  The CU Bus B switch DIS/AUTO is set to
                     AUTO

                 c)  The Disk Ctrl. No. 1 switch AAEN/AUTO/BAEN
                     is set to AUTO



                 d)  The Disk Ctrl. No. 2 switch AAEN/AUTO/BAEN
                     is set to AUTO

                 e)  The Disk Ctrl. No. 3 switch AAEN/AUTO/BAEN
                     is set to AUTO

                 f)  The LTU No. 1 switch AAEN/AUTO/BAEN is
                     set to AUTO

                 g)  The LTU No. 2 switch AAEN/AUTO/BAEN is
                     set to AUTO

                 h)  The LTU No. 3 switch AAEN/AUTO/BAEN is
                     set to AUTO

                 i)  The LTU No. 4 switch AAEN/AUTO/BAEN is
                     set to AUTO

                 k)  The LTU No. 5 switch AAEN/AUTO/BAEN is
                     set to AUTO

                 l)  The SD.FD.CTRL switch AAEN/AUTO/BAEN is
                     set to AUTO

         e)  Switch settings in CU rear crate modules:

             1)  The EN/DIS switch on the CCA module front panel
                 is set to DIS

         f)  Switch settings in TU modules

             1)  All BSM-Xs:

                 a)  The AUTO/MAN/OFF switch is set to MAN

                 b)  The BUS 1/Bus 2 switch is set to BUS 2.

             2)  All LTUX-Ss:

                 a)  The CH 1 switch ON/OFF is set to ON

                 b)  The CH 2 switch ON/OFF is set to ON

                 c)  The CH 3 switch ON/OFF is set to ON

                 d)  The CH 4 switch ON/OFF is set to ON

         g)  Switch settings on frequency stabilizer rack:



             1)  The input power switch on all three stabilizers
                 are set to off.

             2)  The three rotary switches on the By-Pass panel
                 are all set to the Frequency Stabilizer position.

         h)  Setting of power switches in Computer racks:

             1)  Power switch (2) on each Mains switch is set
                 to OFF.

             2)  Power switch (2) on the Disk Drive rear panel
                 is set to "ON"

             3)  Power switch (1) on the Floppy Disk Drive rear
                 panel is set to "ON".

             4)  Power switch (1) on the Watchdog Processor
                 Unit rear panel is set to "OFF".

             5)  Power switch (2) in the rear crate of PU#1
                 is set to "ON"

             6)  Power switch (2) in the rear crate of the CU
                 is set to "ON"

             7)  Power switch (2) in the rear crate of the PU#2
                 is set to "ON".

             8)  Power switch (2) in the rear panel of each
                 80D fan unit is set to "ON".

             9)  Power switch (2) in the rear crate of the Adaptor
                 Crate is set to "ON"

             10) Power switch (1) in the rear panel of the 80S
                 Blower Unit is set to "ON"

             11) Power switch (1) on each CR80D Power supply
                 (6 front crate mounted modules) is set to "ON".

         i)  Setting of Power Switche in Line Termination racks:

             1)  Power Switch (2) on each Mains Switch is set
                 to "OFF".



             2)  Power Switch (1) on the rear panel of each
                 80S Blower Unit is set to "ON".

             3)  Power Switch (2) in the rear crate of each
                 TU is set to "ON".

             4)  Power Switch (1) on each CR80S Power Supply
                 (1 in the front crate of each TU) is set to
                 "ON".

         k)  PU#2 cable interchanges

         Interchange the TIA#1 (rear crate, slot 15) TDX connection
         and the TIA#2 (rear crate, slot 16) TDX connection.

3.7.4.2.2    T̲e̲s̲t̲ ̲I̲n̲i̲t̲i̲a̲l̲i̲z̲a̲t̲i̲o̲n̲

         The testengineers and testwitnesses are in the testroom
         and ready to perform and supervise the test.

         Power Up the DSMT System as follows (Refer to appendix
         A):

         a)  Power Up all connected terminals i.e. VDUs, MSPs,
             OC, PTP/PTR, OCR as applicable.

         b)  The input Power Switch on the front panel of each
             Frequency Stabilizer is set to "ON".

         c)  The power switch (2) on Mains switch no. 1 is set
             to "ON" wait 15 secs.

         d)  The power switch (2) on each of the remaining Mains
             Switche is set to "ON".

         e)  Mount a Disk Pack with the DSMT test software in
             Disk Drive no. 2, close the lid and push the drive
             back in rack B. Activate the WRITE PROTECT pushbutton.

         f)  Activate "START" push button on Disk Drive No.
             2 and wait until the "READY" indicator stays "ON".

         g)  Insert a scratch Floppy Disk in each of the two
             drives in the Floppy Disk drive of rack B, and
             close the lids.


3.7.4.2.3    T̲e̲s̲t̲ ̲S̲t̲e̲p̲s̲

         The teststeps for testgroup no. 7, testprocedure no.
         2 (7/2), is given in the following preceded by a testoverview.




T̲E̲S̲T̲ ̲O̲V̲E̲R̲V̲I̲E̲W̲                                  T̲E̲S̲T̲ ̲N̲O̲.̲:̲ ̲7̲/̲2̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲C̲a̲p̲a̲b̲i̲l̲i̲t̲i̲e̲s̲                                 
    

 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲

Test Case/
Reference        Action                        SRS Reference
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲

1.               CPU test                      N/A

2.               MAP test                      N/A

3.               RAM test                      N/A

4.               Disk/Floppy Disk/LTU/TDX      N/A
                 test

All              Power line filtering          sec. 3.4.5.1.o

All              CPU instruction set           sec. 3.4.5.7.a.4

All              Hardware addressing           sec. 3.4.5.7.a.7




T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲1̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

1.1      OC          Examine printout on OC    Refer to Appendix
                                               D sec. 1.1

1.2      OC          Boot the CPU test pro-
                     gram as follows:

                     Enter from the OC:
                     BA 1025(CR)
                     BM 140(CR)
                     BO A(CR)                  Refer to Appendix
                                               D sec. 1.2

1.3      OC          Enter from the OC
                     REPORTLEVEL = 0(CR)
                     ACTIVATE CPU 0(CR)
                     ACTIVATE CPU 1(CR)
                     ACTIVATE CPU 2(CR)
                     TEST CPU 0 1 2(CR)        Refer to Appendix
                                               D section 1.3.

1.4      OC          Quit the CPU test by en-
                     tering from the OC:
                     QUIT(CR)                  Refer to Appendix
                                               D section 1.4




 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲2̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

2.1      OC          Boot the MAP test pro-
                     gram as follows:

                     Enter from the OC:
                     BA 1025(CR)
                     BM 140(CR)
                     BO 8(CR)                  Refer to Appendix
                                               D sec. 2.1

2.2      OC          Enter from the OC:

                     REPORTLEVEL = 0(CR)
                     TEST ALL(CR)              Refer to Appendix
                                               D section 2.2

2.3      OC          Quit the MAP test by en-
                     tering from the OC:
                     QUIT(CR)                  Refer to Appendix
                                               D section 2.3









 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲3̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

3.1      OC          Boot the RAM test pro-
                     gram as follows:

                     Enter from the OC:
                     BA 1025(CR)
                     BM 140(CR)
                     BO 9(CR)                  Refer to Appendix
                                               D sec. 3.1

3.2      OC          Enter from the OC:

                     REPORTLEVEL = 0(CR)
                     TEST ALL(CR)              Refer to Appendix
                                               D section 3.2

3.3      OC          Quit the RAM test by en-
                     tering from the OC:
                     QUIT(CR)                  Refer to Appendix
                                               D section 3.3









 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲3̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

3.4      OC          Enter from the OC:
                     IR 1A23(CR)
                     IR 1A25(CR)
                     IR 1A26(CR)
                     IR 1A07(CR)
                     IR 1A08(CR)
                     IR 1A0B(CR)
                     IR 1A0D(CR)               Refer to Appendix
                                               D
                                               section 3.4

3.5      OC          Enter from the OC:
                     ZP(CR)                    Either:
                                               ZP
                                               Or:
                                               ZP
                                               Parity error(s)
                                               X












 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲3̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

3.6      OC          Enter from the OC:
                     ZP1(CR)                   Either:
                                               ZP1
                                               Or:
                                               ZP1
                                               Parity error(s)
                                               X
3.7      OC          Enter from the OC:
                     IR 1823(CR)
                     IR 1825(CR)
                     IR 1826(CR)
                     IR 1807(CR)
                     IR 1808(CR)
                     IR 180B(CR)
                     IR 180D(CR)               Refer to Appendix
                                               D
                                               section 3.5

                     The steps from 3.4
                     to 3.7 incl. has reset
                     possible parity errors
                     in the CU memories








 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.1      OC          Boot the Disk test-
                     program as follows:
                     Enter from the OC:
                     BA 1025(CR)
                     BM 140(CR)
                     BO 4(CR)                  Refer to Appendix
                                               D
                                               sec. 4.1

4.2      N/A         Depress the "START"       N/A.
                     pushbutton on disk
                     drive #2 and wait un-
                     til the "START"and
                     "READY" indicators are
                     "OFF". Replace the test
                     software disk pack in
                     Disk Drive # 2 with a
                     scratch disk pack.
                     Push the drive back
                     into rack B.
                     Activate the "START"
                     pushbutton on Drive #2
                     and wait until the
                     "READY"indicator stays
                     "ON". Depress the
                     WRITE PROTECT push-
                     button.


 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.3      OC          Activate the Disk test
                     as follows:

                     Enter from the OC:        Refer to Appendix
                                               D
                     DO TEST ̲DISKS             sec. 4.2
                     (Appendix C, sec. 2.1)

4.4      OC          Quit the Disk test
                     by entering from the OC:  Refer to Appendix
                                               D
                     QUIT(CR)                  sec. 4.3

4.5      N/A         Depress the "START"       N/A.
                     pushbutton on disk
                     drive #2 and wait un-
                     til the "START"and
                     "READY" indicators are
                     "OFF". Replace the
                     scratch disk pack in
                     Disk Drive # 2 with the
                     test software disk pack.
                     Push the drive back
                     into rack B.
                     Activate the "START"
                     pushbutton on Drive #2
                     and wait until the
                     "READY"indicator stays
                     "ON". Activate the WRITE
                     PROTECT pushbutton.
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.6      OC          Boot the Floppy
                     Disk test program as
                     follows:
                     Enter from the OC:
                     BA 1025(CR)
                     BM 140(CR)
                     BO 5(CR)                  Refer to Appendix
                                               D
                                               sec. 4.4

4.7      OC          Activate the Floppy
                     Disk test as follows:
                     Enter from the OC:        Refer to Appendix
                                               D
                     DO TEST ̲FLOPPY ̲DISKS      sec. 4.5
                     (Appendix C, sec. 2.1)

4.8      OC          Quit the Floppy Disk test
                     by entering from the OC:  Refer to Appendix
                                               D
                     QUIT(CR)                  sec. 4.3










 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.9      OC          Boot the LTU test-
                     program as follows:
                     Enter from the OC:
                     BA 1025(CR)
                     BM 140(CR)                Refer to Appendix
                                               D
                     BO 6(CR)                  sec. 4.6

4.10     N/A         Connect the TEST VDU      N/A
                     to J30 in the V24 fil-
                     ter box via testcable C.

4.11     OC          Activate the LTU#1
                     channel 1 test as follows:

                     Enter from the OC:        Refer to Appendix
                                               D
                     DO LTU11(CR)              sec. 4.7
                     (Appendix C, sec. 3.1)

4.12     N/A         Connect the TEST VDU      N/A
                     to J31 in the V24 fil-
                     ter box via testcable C.

4.13     OC          Activate the LTU#2
                     channel 1 test as follows:

                     Enter from the OC:        Refer to Appendix
                                               D
                     DO LTU21(CR)              sec. 4.8
                     (Appendix C, sec. 3.2)
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.14     N/A         Connect the available     N/A
                     testconfiguration
                     to J26 in the V24 fil-
                     ter box via a testcable.
                     The possible testcon-
                     figurations and test-
                     cables are described
                     in sec. 3.7.1.b2

4.15     OC          Activate the LTU#3
                     channel 1 test as follows:

                     Enter from the OC:        Refer to Appendix
                                               D
                     DO LTU31(CR)              sec. 4.9
                     (Appendix C, sec. 3.3)













 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.16     N/A         Connect the available     N/A
                     testconfiguration
                     to J27 in the V24 fil-
                     ter box via a testcable.
                     The possible test-
                     configurations and test-
                     cables are described
                     in sec. 3.7.1.b2

4.17     OC          Activate the LTU#3
                     channel 2 test as follows:

                     Enter from the OC:        Refer to Appendix
                                               D
                     DO LTU32(CR)              sec. 4.10
                     (Appendix C, sec. 3.4)













 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.18     N/A         Connect the available     N/A
                     testconfiguration
                     to J28 in the V24 fil-
                     ter box via a testcable.
                     The possible test-
                     configurations and test-
                     cables are described
                     in sec. 3.7.1.b2

4.19     OC          Activate the LTU#4
                     channel 1 test as follows:

                     Enter from the OC:        Refer to Appendix
                                               D
                     DO LTU41(CR)              sec. 4.11
                     (Appendix C, sec. 3.5)













 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.20     N/A         Connect the available     N/A
                     testconfiguration
                     to J29 in the V24 fil-
                     ter box via a testcable.
                     The possible test-
                     configurations and test-
                     cables are described
                     in sec. 3.7.1.b2

4.21     OC          Activate the LTU#4
                     channel 2 test as follows:
                     Enter from the OC:        Refer to Appendix
                                               D
                     DO LTU42(CR)              sec. 4.12
                     (Appendix C, sec. 3.6)

4.22     N/A         Remove the test confi-    N/A
                     guration from J29 in
                     the V24 filter box.

4.23     OC          Quit the LTU test by
                     entering from the OC:     Refer to Appendix
                                               D
                     QUIT(CR)                  sec. 4.3

4.24     OC          Boot the TDX1 test pro-
                     gram as follows:
                     BA 1025(CR)
                     BM 140(CR)                Refer to Appendix
                                               D
                     BO 7(CR)                  sec 4.13
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.25     OC          Activate the link 111
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN111(CR)
                     (Appendix C, sec. 4.3a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    VDU 111 display
                                               as
                     DO CLOSE111(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.3b)   dix D, sec. 4.14

4.26     OC          Activate the link 112
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN112(CR)
                     (Appendix C, sec. 4.4a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    VDU 112 display
                                               as
                     DO CLOSE112(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.4b)   dix D, sec. 4.14





 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.27     OC          Activate the link 113
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN113(CR)
                     (Appendix C, sec. 4.5a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    VDU 113 display
                                               as
                     DO CLOSE113(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.5b)   dix D, sec. 4.14

4.28     OC          Activate the link 114
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN114(CR)
                     (Appendix C, sec. 4.6a)
                     DO MSP(CR)
                     (Appendix C, sec. 4.2)    MSP 114 print
                                               out as
                     DO CLOSE114(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.6b)   dix D, sec. 4.15





 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.29     OC          Activate the link 211
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN211(CR)
                     (Appendix C, sec. 4.7a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    VDU 211 display
                                               as
                     DO CLOSE211(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.7b)   dix D, sec. 4.14

4.30     OC          Activate the link 212
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN212(CR)
                     (Appendix C, sec. 4.8a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    VDU 212 display
                                               as
                     DO CLOSE212(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.8b)   dix D, sec. 4.14





 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.31     OC          Activate the link 213
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN213(CR)
                     (Appendix C, sec. 4.9a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    VDU 213 display
                                               as
                     DO CLOSE213(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.9b)   dix D, sec. 4.14

4.32     OC          Activate the link 214
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN214(CR)
                     (Appendix C, sec. 4.10a)
                     DO MSP(CR)
                     (Appendix C, sec. 4.2)    MSP 214 print
                                               out as
                     DO CLOSE214(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.10b)  dix D, sec. 4.15





 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.33     OC          Activate the link 121
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN121(CR)
                     (Appendix C, sec. 4.11a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    VDU 121 display
                                               as
                     DO CLOSE121(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.11b)  dix D, sec. 4.14

4.34     OC          Activate the link 122
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN122(CR)
                     (Appendix C, sec. 4.12a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    VDU 122 display
                                               as
                     DO CLOSE122(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.12b)  dix D, sec. 4.14





 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.35     OC          Activate the link 123
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN123(CR)
                     (Appendix C, sec. 4.13a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    VDU 123 display
                                               as
                     DO CLOSE123(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.13b)  dix D, sec. 4.14

4.36     OC          Activate the link 124
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN124(CR)
                     (Appendix C, sec. 4.14a)
                     DO MSP(CR)
                     (Appendix C, sec. 4.2)    MSP 124 print
                                               out as
                     DO CLOSE124(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.14b)  dix D, sec. 4.15





 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.37     OC          Activate the link 221
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN221(CR)
                     (Appendix C, sec. 4.15a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    VDU 221 display
                                               as
                     DO CLOSE221(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.15b)  dix D, sec. 4.14

4.38     OC          Activate the link 222
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN222(CR)
                     (Appendix C, sec. 4.16a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    VDU 222 display
                                               as
                     DO CLOSE222(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.16b)  dix D, sec. 4.14





 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.39     OC          Activate the link 223
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN223(CR)
                     (Appendix C, sec. 4.17a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    VDU 223 display
                                               as
                     DO CLOSE223(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.17b)  dix D, sec. 4.14

4.40     OC          Activate the link 224
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN224(CR)
                     (Appendix C, sec. 4.18a)
                     DO MSP(CR)
                     (Appendix C, sec. 4.2)    MSP 224 print
                                               out as
                     DO CLOSE224(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.18b)  dix D, sec. 4.15





 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.41     OC          Quit the TDX1 test by
                     entering from the OC:     Refer to Appendix
                                               D
                     QUIT(CR)                  sec. 4.3

4.42     OC          Boot the TDX2 test as
                     follows:
                     BA 1025(CR)
                     BM 140(CR)                Refer to Appendix
                                               D
                     BO 2A6(CR)                sec. 4.16



















 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.43     OC          Activate the link 141
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN141(CR)
                     (Appendix C, sec. 4.23a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    VDU 141 display
                                               as
                     DO CLOSE141(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.23b)  dix D, sec. 4.14

4.44     OC          Activate the link 142
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN142(CR)
                     (Appendix C, sec. 4.24a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    VDU 142 display
                                               as
                     DO CLOSE142(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.24b)  dix D, sec. 4.14





 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.45     OC          Activate the link 143
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN143(CR)
                     (Appendix C, sec. 4.25a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    VDU 143 display
                                               as
                     DO CLOSE143(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.25b)  dix D, sec. 4.14

4.46     OC          Activate the link 144
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN144(CR)
                     (Appendix C, sec. 4.26a)
                     DO MSP(CR)
                     (Appendix C, sec. 4.2)    MSP 144 print
                                               out as
                     DO CLOSE144(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.26b)  dix D, sec. 4.15





 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.47     OC          Activate the link 241
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN241(CR)
                     (Appendix C, sec. 4.27a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    VDU 241 display
                                               as
                     DO CLOSE241(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.27b)  dix D, sec. 4.14

4.48     OC          Activate the link 242
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN242(CR)
                     (Appendix C, sec. 4.28a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    VDU 242 display
                                               as
                     DO CLOSE242(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.28b)  dix D, sec. 4.14





 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.49     OC          Activate the link 243
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN243(CR)
                     (Appendix C, sec. 4.29a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    VDU 243 display
                                               as
                     DO CLOSE243(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.29b)  dix D, sec. 4.14

4.50     OC          Activate the link 244
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN244(CR)
                     (Appendix C, sec. 4.30a)
                     DO MSP(CR)
                     (Appendix C, sec. 4.2)    MSP 244 print
                                               out as
                     DO CLOSE244(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.30b)  dix D, sec. 4.15





 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.51     OC          Quit the TDX2 test by
                     entering from the OC:     Refer to Appendix
                                               D
                     QUIT(CR)                  sec. 4.3

4.52     OC          Boot the TDX3 test as
                     follows:
                     BA 1025(CR)
                     BM 140(CR)                Refer to Appendix
                                               D
                     BO 2CD(CR)                sec. 4.17



















 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.53     OC          Activate the link 151
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN151(CR)
                     (Appendix C, sec. 4.31a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    VDU 151 display
                                               as
                     DO CLOSE151(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.31b)  dix D, sec. 4.14

4.54     OC          Activate the link 152
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN152(CR)
                     (Appendix C, sec. 4.32a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    VDU 152 display
                                               as
                     DO CLOSE152(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.32b)  dix D, sec. 4.14





 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.55     OC          Activate the link 153
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN153(CR)
                     (Appendix C, sec. 4.33a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    VDU 153 display
                                               as
                     DO CLOSE153(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.33b)  dix D, sec. 4.14

4.56     OC          Activate the link 154
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN154(CR)
                     (Appendix C, sec. 4.34a)
                     DO MSP(CR)
                     (Appendix C, sec. 4.2)    MSP 154 print
                                               out as
                     DO CLOSE154(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.34b)  dix D, sec. 4.15





 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.57     OC          Activate the link 251
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN251(CR)
                     (Appendix C, sec. 4.35a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    VDU 251 display
                                               as
                     DO CLOSE251(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.35b)  dix D, sec. 4.14

4.58     OC          Activate the link 252
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN252(CR)
                     (Appendix C, sec. 4.36a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    VDU 252 display
                                               as
                     DO CLOSE252(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.36b)  dix D, sec. 4.14





 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.59     OC          Activate the link 253
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN253(CR)
                     (Appendix C, sec. 4.37a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    VDU 253 display
                                               as
                     DO CLOSE253(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.37b)  dix D, sec. 4.14

4.60     OC          Activate the link 254
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN254(CR)
                     (Appendix C, sec. 4.38a)
                     DO MSP(CR)
                     (Appendix C, sec. 4.2)    MSP 254 print
                                               out as
                     DO CLOSE254(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.38b)  dix D, sec. 4.15





 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.61     OC          Quit the TDX3 test by
                     entering from the OC:     Refer to Appendix
                                               D
                     QUIT(CR)                  sec. 4.3

4.62     OC          Boot the TDX2 test as
                     follows:
                     BA 1025(CR)
                     BM 140(CR)                Refer to Appendix
                                               D
                     BO 2A6(CR)                sec. 4.16



















 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.63     N/A         Power down TU#3.
                     Connect the TEST VDU
                     (V24 I/F) to J1 in
                     the V24 filter box
                     Power up TU#3             N/A

4.64     OC          Activate the link 131
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO Open131(CR)
                     (Appendix C, sec. 4.19a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    TEST VDU display
                                               as
                     DO CLOSE131(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.19b)  dix D, sec. 4.14











 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.65     N/A         Power down TU#3.
                     Connect the TEST VDU
                     (V24 I/F) to J2 in
                     the V24 filter box
                     Power up TU#3             N/A

4.66     OC          Activate the link 132
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN132(CR)
                     (Appendix C, sec. 4.20a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    TEST VDU display
                                               as
                     DO CLOSE132(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.20b)  dix D, sec. 4.14











 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.67     N/A         Power down TU#3
                     Connect the TEST VDU
                     (V24 I/F) to J3 in
                     the V24 filter box
                     Power up TU#3             N/A

4.68     OC          Activate the link 133
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN133(CR)
                     (Appendix C, sec. 4.21a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    TEST VDU display
                                               as
                     DO CLOSE133(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.21b)  dix D, sec. 4.14











 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.69     N/A         Power down TU#3
                     Connect the TEST VDU
                     (V24 I/F) to J4 in
                     the V24 filter box
                     Power up TU#3             N/A

4.70     OC          Activate the link 134
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN134(CR)
                     (Appendix C, sec. 4.22a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    TEST VDU display
                                               as
                     DO CLOSE134(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.22b)  dix D, sec. 4.14











 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.71     OC          Quit the TDX2 test by
                     entering from the OC:     Refer to Appendix
                                               D
                     QUIT(CR)                  sec. 4.3

4.72     OC          Boot the TDX3 test as
                     follows:
                     BA 1025(CR)
                     BM 140(CR)                Refer to Appendix
                                               D
                     BO 2CD(CR)                sec. 4.17



















 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.73     N/A         Power down TU#6
                     Connect the TEST VDU
                     (V24 I/F) to J5 in
                     the V24 filter box
                     Power up TU#6             N/A

4.74     OC          Activate the link 161
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN161(CR)
                     (Appendix C, sec. 4.39a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    TEST VDU display
                                               as
                     DO CLOSE161(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.39b)  dix D, sec. 4.14











 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.75     N/A         Power down TU#6
                     Connect the TEST VDU
                     (V24 I/F) to J6 in
                     the V24 filter box
                     Power up TU#6             N/A

4.76     OC          Activate the link 162
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN162(CR)
                     (Appendix C, sec. 4.40a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    TEST VDU display
                                               as
                     DO CLOSE162(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.40b)  dix D, sec. 4.14











 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.77     N/A         Power down TU#6
                     Connect the TEST VDU
                     (V24 I/F) to J7 in
                     the V24 filter box
                     Power up TU#6             N/A

4.78     OC          Activate the link 163
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN163(CR)
                     (Appendix C, sec. 4.41a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    TEST VDU display
                                               as
                     DO CLOSE163(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.41b)  dix D, sec. 4.14











 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.79     N/A         Power down TU#6
                     Connect the TEST VDU
                     (V24 I/F) to J8 in
                     the V24 filter box
                     Power up TU#6             N/A

4.80     OC          Activate the link 164
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN164(CR)
                     (Appendix C, sec. 4.42a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    TEST VDU display
                                               as
                     DO CLOSE164(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.42b)  dix D, sec. 4.14











 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.81     N/A         Power down TU#7
                     Connect the TEST VDU
                     (V24 I/F) to J9 in
                     the V24 filter box
                     Power up TU#7             N/A

4.82     OC          Activate the link 171
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN171(CR)
                     (Appendix C, sec. 4.43a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    TEST VDU display
                                               as
                     DO CLOSE171(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.43b)  dix D, sec. 4.14











 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.83     N/A         Power down TU#7
                     Connect the TEST VDU
                     (V24 I/F) to J10 in
                     the V24 filter box
                     Power up TU#7             N/A

4.84     OC          Activate the link 172
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN172(CR)
                     (Appendix C, sec. 4.44a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    TEST VDU display
                                               as
                     DO CLOSE172(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.44b)  dix D, sec. 4.14











 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.85     N/A         Power down TU#7
                     Connect the TEST VDU
                     (V24 I/F) to J11 in
                     the V24 filter box
                     Power up TU#7             N/A

4.86     OC          Activate the link 173
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN173(CR)
                     (Appendix C, sec. 4.45a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    TEST VDU display
                                               as
                     DO CLOSE173(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.45b)  dix D, sec. 4.14











 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.87     N/A         Power down TU#7
                     Connect the TEST VDU
                     (V24 I/F) to J12 in
                     the V24 filter box
                     Power up TU#7             N/A

4.88     OC          Activate the link 174
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN174(CR)
                     (Appendix C, sec. 4.46a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    TEST VDU display
                                               as
                     DO CLOSE174(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.46b)  dix D, sec. 4.14











 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.89     OC          Quit the TDX3 test by
                     entering from the OC:     Refer to Appendix
                                               D
                     QUIT(CR)                  sec. 4.3

4.90     OC          Boot the TDX4 test as
                     follows:
                     BA 1025(CR)
                     BM 140(CR)                Refer to Appendix
                                               D
                     BO 2CE(CR)                sec. 4.18



















 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.91     N/A         Power down TU#8
                     Connect the TEST VDU
                     (V24 I/F) to J13 in
                     the V24 filter box
                     Power up TU#8             N/A

4.92     OC          Activate the link 181
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN181(CR)
                     (Appendix C, sec. 4.47a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    TEST VDU display
                                               as
                     DO CLOSE181(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.47b)  dix D, sec. 4.14











 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.93     N/A         Power down TU#8
                     Connect the TEST VDU
                     (V24 I/F) to J14 in
                     the V24 filter box
                     Power up TU#8             N/A

4.94     OC          Activate the link 182
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN182(CR)
                     (Appendix C, sec. 4.48a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    TEST VDU display
                                               as
                     DO CLOSE182(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.48b)  dix D, sec. 4.14











 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.95     N/A         Power down TU#8
                     Connect the TEST VDU
                     (V24 I/F) to J15 in
                     the V24 filter box
                     Power up TU#8             N/A

4.96     OC          Activate the link 183
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN183(CR)
                     (Appendix C, sec. 4.49a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    TEST VDU display
                                               as
                     DO CLOSE183(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.49b)  dix D, sec. 4.14











 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.97     N/A         Power down TU#8
                     Connect the TEST VDU
                     (V24 I/F) to J16 in
                     the V24 filter box
                     Power up TU#8             N/A

4.98     OC          Activate the link 184
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN184(CR)
                     (Appendix C, sec. 4.50a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    TEST VDU display
                                               as
                     DO CLOSE184(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.50b)  dix D, sec. 4.14











 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.99     N/A         Power down TU#9
                     Connect the TEST VDU
                     (V24 I/F) to J17 in
                     the V24 filter box
                     Power up TU#9             N/A

4.100    OC          Activate the link 191
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN191(CR)
                     (Appendix C, sec. 4.51a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    TEST VDU display
                                               as
                     DO CLOSE191(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.51b)  dix D, sec. 4.14











 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.101    N/A         Power down TU#9
                     Connect the TEST VDU
                     (V24 I/F) to J18 in
                     the V24 filter box
                     Power up TU#9             N/A

4.102    OC          Activate the link 192
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN192(CR)
                     (Appendix C, sec. 4.52a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    TEST VDU display
                                               as
                     DO CLOSE192(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.52b)  dix D, sec. 4.14











 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.103    N/A         Power down TU#9
                     Connect the TEST VDU
                     (V24 I/F) to J19 in
                     the V24 filter box
                     Power up TU#9             N/A

4.104    OC          Activate the link 193
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN193(CR)
                     (Appendix C, sec. 4.53a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    TEST VDU display
                                               as
                     DO CLOSE193(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.53b)  dix D, sec. 4.14











 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.105    N/A         Power down TU#9
                     Connect the TEST VDU
                     (V24 I/F) to J20 in
                     the V24 filter box
                     Power up TU#9             N/A

4.106    OC          Activate the link 194
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN194(CR)
                     (Appendix C, sec. 4.54a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    TEST VDU display
                                               as
                     DO CLOSE194(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.54b)  dix D, sec. 4.14











 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.107    N/A         Power down TU#9
                     Connect the TEST VDU
                     (V24 I/F) to J21 in
                     the V24 filter box
                     Power up TU#9             N/A

4.108    OC          Activate the link 291
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN291(CR)
                     (Appendix C, sec. 4.55a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    TEST VDU display
                                               as
                     DO CLOSE291(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.55b)  dix D, sec. 4.14











 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.109    N/A         Power down TU#9
                     Connect the TEST VDU
                     (V24 I/F) to J22 in
                     the V24 filter box
                     Power up TU#9             N/A

4.110    OC          Activate the link 292
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN292(CR)
                     (Appendix C, sec. 4.56a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    TEST VDU display
                                               as
                     DO CLOSE292(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.56b)  dix D, sec. 4.14











 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.111    N/A         Power down TU#9
                     Connect the TEST VDU
                     (V24 I/F) to J23 in
                     the V24 filter box
                     Power up TU#9             N/A

4.112    OC          Activate the link 293
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN293(CR)
                     (Appendix C, sec. 4.57a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    TEST VDU display
                                               as
                     DO CLOSE293(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.57b)  dix D, sec. 4.14











 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.113    N/A         Power up TU#9
                     Connect the TEST VDU
                     (V24 I/F) to J24 in
                     the V24 filter box
                     Power up TU#9             N/A

4.114    OC          Activate the link 294
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN294(CR)
                     (Appendix C, sec. 4.58a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    TEST VDU display
                                               as
                     DO CLOSE294(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.58b)  dix D, sec. 4.14











 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.115    N/A         Power down TU#10
                     Connect the PTP/PTR
                     (V24 I/F) to J25 in
                     the V24 filter box
                     Power up TU#10            N/A

4.116    OC          Activate the link 1A1
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:        A peace of tape
                                               is
                     DO PTP(CR)                punched. Tear
                                               it off
                     (Appendix C, sec. 5.1a)   and feed it into
                                               the
                                               reader.

                     Enter from the OC:        OC print out
                                               as
                     DO PTR(CR)                specified in
                                               appen
                     (Appendix C, sec. 5.1b)   dix D sec. 4.19










 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.117    N/A         If the OCR is unavailable
                     then proceed from step
                     4.120 else continue from
                     4.118.

4.118    N/A         Power down TU#10
                     Connect the OCR to J32
                     in the V24 filterbox
                     Power up TU#10            N/A

4.119    OC          Activate the link 2A1
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:        OC print out
                                               in con-
                     DO OCR(CR)                formance with
                                               the OCR
                     (Appendix C, sec. 5.2)    input.

                     Proceed from step 4.122.









 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR



T̲E̲S̲T̲ ̲S̲T̲E̲P̲S̲                                                           T̲E̲S̲T̲
                                                                     ̲N̲O̲.̲:̲
                                                                     ̲7̲/̲2̲/̲4̲

F̲U̲N̲C̲T̲I̲O̲N̲:̲ ̲ ̲P̲U̲#̲2̲/̲C̲U̲/̲T̲D̲X̲#̲2̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲T̲e̲s̲t̲

S̲R̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲:̲ ̲ ̲S̲e̲c̲s̲.̲ ̲3̲.̲4̲.̲5̲.̲1̲.̲o̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲4̲,̲ ̲3̲.̲4̲.̲5̲.̲7̲.̲a̲.̲7̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

Case     Test
Step No. Station     Action                    Expected Results
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

4.120    N/A         Power down TU#10
                     Connect the TEST VDU to
                     J32 in the V24 filterbox
                     Power up TU#10            N/A

4.121    OC          Activate the link 2A1
                     LTUX-S test as fol-
                     lows:

                     Enter from the OC:
                     DO OPEN2A1(CR)
                     (Appendix C, sec. 4.59a)
                     DO VDU(CR)
                     (Appendix C, sec. 4.1)    TEST VDU display
                                               as
                     DO CLOSE2A1(CR)           specified in
                                               appen-
                     (Appendix C, sec. 4.59b)  dix D, sec. 4.14

4.122    OC          Quit the test by
                     entering from the OC:
                     QUIT(CR)                  Ref. to Appendix
                                               D sec. 4.3

4.123    N/A         Remove the TEST VDU/OCR
                     from J32 in the fil-
                     ter box.                  N/A



 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
Comments:





                                                ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                               ̲ ̲
                                               T̲E̲S̲T̲ ̲W̲I̲T̲N̲E̲S̲S̲E̲S̲

                                               TEST QA   QAR


3.7.4.2.4            T̲e̲s̲t̲ ̲T̲e̲r̲m̲i̲n̲a̲t̲i̲o̲n̲

         Power Down the DSMT system as Follows:

         a)          Depress "START" push button on Disk Drive
                     # 2 and wait until he "START" and "READY"
                     indicators are "OFF".

         b)          Remove the Disk Pack from Disk Drive #
                     2, close the lid and push the drive back
                     in rack B

         c)          The two scratch Floppy Disks are removed
                     from the Floppy Disk drive in rack C. Close
                     the lids.

         d)          The Power Switch (2) on each Mains Switch
                     is set to "OFF".

         e)          The input power switch on each Frequency
                     Stabilizer is set to "OFF"

         f)          Power Down all connected Terminals i.e.
                     VDUs, MSPs, OC, PTP/PTR, as applicable.

         g)          Disconnect the OC from the leftmost V24/V28(L/L)
                     adaptor in the Adaptor crate of rack C,
                     and replace this adaptor with the originally
                     mounted OPTO transceiver.

         h)          Disconnect the two V24 cables (at the WDP
                     rear crate), remove the short extension
                     cable and reconnect the two cables to J2
                     and J3 respectively.

         i)          Interchange the TIA#1 (PU#2 rear crate,
                     slot 15) TDX connection and the TIA#2 (PU#2
                     rear crate, slot 16) TDX connection.

         j)          Set the host number on the STI (PU#2 front
                     crate, slot 18) to #02 on switch S1 as
                     follows:

                     S1,4 : CLOSED
                     S1,3 : CLOSED
                     S1,2 : OPEN
                     S1,1 : CLOSED