⟦c464f386b⟧ Wang Wps File

    Length: 8949 (0x22f5)
    Types: Wang Wps File
    Notes: FIX/1256/PSP/0056         
    Names: »4665A «

Derivation

└─⟦0a6a0cf2a⟧ Bits:30006130 8" Wang WCS floppy, CR 0296A
    └─ ⟦this⟧ »4665A « 

WangText

…09……00……00……00……00…A…0a……86…1                                             …02…           …02…   …02…   

   4665A…02…FIX/1256/PSP/0056

…02…JL/840229…02……02…#
FIKS LOG ̲ACTION PROCEDURE PSP
…02……02…  FIKS 













…0e…
                 FIKS LOG ̲ACTION PROCEDURE PSP


                 FIX/1256/PSP/0056


…0f…










                 J]rgen Lindballe 




                 Ole Eskedal 








                 AMC (6), APE, LOL, LU, REV, JL 
















                           FIKS S/W Mgr    840229

                           FIKS Conf.Mgr   840229
         1          



         840229
                                                   …86…1       
                                                          …02… 
                              …02…   …02…     

    4665A   …02… FIX/1256/PSP/0056

…02… JL/840229…02……02…ii
FIKS LOG ̲ACTION PROCEDURE PSP
…02……02…    FIKS 















        840229                 All      Issue 1 of Document











   4665A…02…FIX/1256/PSP/0056

…02…JL/840229…02……02…iii
FIKS LOG ̲ACTION PROCEDURE PSP
…02……02…  FIKS 





                                      T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲




     1 SCOPE ........................................  
       1 
       1.1 INTRODUCTION .............................  
           1 
       1.2 ABBREVIATONS .............................  
           1 
       1.3 DEFINITION OF TERMS ......................  
           1 

     2 APPLICABLE DOCUMENTS .........................  
       2 

     3 MODULE SPECIFICATION .........................  
       3 
       3.1 FUNCTIONAL CAPABILITIES ..................  
           3 
       3.2 INTERFACE DESCRIPTION ....................  
           3 
       3.3 PROCESSING ...............................  
           4 
         3.3.1 The Procedure ........................  
               4 
         3.3.2 Initialization .......................  
               6 

       3.4 DATA ORGANIZATION ........................  
           6 
         3.4.1 Data Bases ...........................  
               6 
         3.4.2 Queues ...............................  
               6 
         3.4.3 Buffers ..............................  
               6 
         3.4.4 Tables ...............................  
               6 
         3.4.5 Constants and Variables ..............  
               6 

       3.5 STORAGE ALLOCATION .......................  
           7 
         3.5.1 Memory Space Requirements ............  
               7 
         3.5.2 Disc Space Requirements ..............  
               7 
       3.6 PERFORMANCE CHARACTERISTICS ..............  
           7 
       3.7 LIMITATIONS ..............................  
           7 
       3.8 ERROR CODES ..............................  
           7 
         3.8.1 Kernel ...............................  
               7 
         3.8.2 I/O System ...........................  
               7 
         3.8.3 QACCESS ..............................  
               8 
         3.8.4 MTCB Monitor .........................  
               8 
       3.9 LISTING REFERENCES .......................  
           8 

     4 QUALITY ASSURANCE ............................  
       9 
       4.1 QUALIFICATION TESTS ......................  
           9 
       4.2 OTHER QUALITY ASSURANCE PROVISIONS .......  
           9 

     5 PREPARATION FOR DELIVERY .....................  10
       





                         1  S̲C̲O̲P̲E̲



1.1      I̲N̲T̲R̲O̲D̲U̲C̲T̲I̲O̲N̲

         This document specifies the L̲O̲G̲-̲A̲C̲T̲I̲O̲N̲ monitor procedure
         within the FIKS application software. The design is
         based on issue 5 of the Requirements Specifications.

         The main tasks of the procedure are:

         -   to create a pseudo MTCB, and to fill it with information
             from the input block

         -   to insert the pseudo MTCB in the LP queue of the
             Log Printer

         -   to release the pseudo MTCB.



1.2      A̲B̲B̲R̲E̲V̲I̲A̲T̲O̲N̲S̲

         LP      Log Printer
         MTCB    Message Transition Control Block



1.3      D̲E̲F̲I̲N̲I̲T̲I̲O̲N̲ ̲O̲F̲ ̲T̲E̲R̲M̲S̲

         MESSAGE TRANSITION CONTROL BLOCK (MTCB)

         A core resident representive for a message or a message
         related event.





                 2  A̲P̲P̲L̲I̲C̲A̲B̲L̲E̲ ̲D̲O̲C̲U̲M̲E̲N̲T̲S̲

         1.  REQUIREMENTS SPECIFICATION
             FIX/0000/SPC/0002
             Vol. I-III

         2.  FIKS SYSTEM DESIGN SPECIFICATION
             FIX/1000/DSP/0001
             

         3.  FIKS SOFTWARE INTERFACE REFERENCE
             FIX/0100/MAN/0003
             

         4.  FIKS DATA INTERFACE REFERENCE
             FIX/0100/MAN/0004
             

         5.  CR80 AMOS KERNEL
             CSS/302/PSP/0008
             

         6.  CR80 AMOS I/O SYSTEM
             CSS/006/PSP/0006
             

         7.  CR80 FILE SYSTEM PSP
             CSS/910/EWP/0001
             

         8.  SUPPORT SOFTWARE DESIGN SPECIFICATION
             FIX/1103/DSP/0009
             

         9.  TEST REPORT FOR MISC. SUPPORT S/W PROCEDURES
             FIX/1203/TRP/0024
             





                 3  M̲O̲D̲U̲L̲E̲ ̲S̲P̲E̲C̲I̲F̲I̲C̲A̲T̲I̲O̲N̲



3.1      F̲U̲N̲C̲T̲I̲O̲N̲A̲L̲ ̲C̲A̲P̲A̲B̲I̲L̲I̲T̲I̲E̲S̲

         The logging facility prepares a print at the MEDE log
         printer of events of different types.



3.2      I̲N̲T̲E̲R̲F̲A̲C̲E̲ ̲D̲E̲S̲C̲R̲I̲P̲T̲I̲O̲N̲

         MON LOG ̲ACTION

         Register use at:

         CALL                           EXIT

         R4 Ref. (Workarea)             Unchanged
         R7 Link                        Completion Code
         
         Use of return points:

             Link+0: Error
             Link+1: Done 

         Work area of 21 words:

               ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
             ^ ̲T̲Y̲P̲E̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^  0     unchanged
             ^ ̲T̲E̲R̲M̲ ̲N̲O̲.̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^  1
             ^ ̲U̲S̲E̲R̲ ̲I̲D̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^  2..3
             ^                   ^
             ^                   ^
             ^ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲^  20





3.3      P̲R̲O̲C̲E̲S̲S̲I̲N̲G̲



3.3.1    T̲h̲e̲ ̲P̲r̲o̲c̲e̲d̲u̲r̲e̲

         Logging of events is initiated by the individual application
         subsystems which via this monitor procedure LOG ̲ACTION
         insert an entry in a log printer queue. The queue entry
         points to a pseudo MTCB, which describes the cause
         of the logging.

         The log printer is localized by means of the terminal
         configuration table.

         The events logged are described in ref. 3, section
         3.6.6.

         The flow chart is shown overleaf:

         1.  The module is invoked by a procedure call from
             an application subsystem. The call implies transfer
             of a parameter block defining the logging event
             and the user.

         2.  A pseudo MTCB is created.

         3.  The input parameter block is decoded and the contents
             written into the pseudo MTCB.

         4.  The log printers logical terminal number is found
             in the terminal configuration table.

         5.  The pseudo MTCB is inserted in the "LP" precedence
             queue at the log printer.

         6.  The pseudo MTCB is released.

         7.  The module transfers control to the caller.




















































           Figure 3.3.1-1…01…Procedure LOG ̲ACTION



3.3.2    I̲n̲i̲t̲i̲a̲l̲i̲z̲a̲t̲i̲o̲n̲

         During the initialization, the MON ̲INIT procedure is
         called.



3.4      D̲A̲T̲A̲ ̲O̲R̲G̲A̲N̲I̲Z̲A̲T̲I̲O̲N̲



3.4.1    D̲a̲t̲a̲ ̲B̲a̲s̲e̲s̲

         Not applicable.



3.4.2    Q̲u̲e̲u̲e̲s̲

         The format of the pseudo MTCB inserted in the LP queue
         is described in ref. 4, section 7.1, figure 7.1.2.3.



3.4.3    B̲u̲f̲f̲e̲r̲s̲

         The buffer delivered by the calling process is used
         for:

         -   input parameters

         -   register save area and

         -   working area (e.g. MTCB-block, QIOCB).



3.4.4    T̲a̲b̲l̲e̲s̲

         The configuration table (see ref. 4, section 11.5)
         is used to extract the logical terminal number of the
         log printer.



3.4.5    C̲o̲n̲s̲t̲a̲n̲t̲s̲ ̲a̲n̲d̲ ̲V̲a̲r̲i̲a̲b̲l̲e̲s̲

         Not applicable





3.5      S̲T̲O̲R̲A̲G̲E̲ ̲A̲L̲L̲O̲C̲A̲T̲I̲O̲N̲



3.5.1    M̲e̲m̲o̲r̲y̲ ̲S̲p̲a̲c̲e̲ ̲R̲e̲q̲u̲i̲r̲e̲m̲e̲n̲t̲s̲

         Program size = 136 words.



3.5.2    D̲i̲s̲c̲ ̲S̲p̲a̲c̲e̲ ̲R̲e̲q̲u̲i̲r̲e̲m̲e̲n̲t̲s̲

         No disc space is required.



3.6      P̲E̲R̲F̲O̲R̲M̲A̲N̲C̲E̲ ̲C̲H̲A̲R̲A̲C̲T̲E̲R̲I̲S̲T̲I̲C̲S̲

         Not applicable



3.7      L̲I̲M̲I̲T̲A̲T̲I̲O̲N̲S̲

         Not applicable.



3.8      E̲R̲R̲O̲R̲ ̲C̲O̲D̲E̲S̲



3.8.1    K̲e̲r̲n̲e̲l̲

         Copying of the Log Printer Id from the Critical Region
         "Configuration Table":

         CC equal to completion code.



3.8.2    I̲/̲O̲ ̲S̲y̲s̲t̲e̲m̲

         Not applicable.





3.8.3    Q̲A̲C̲C̲E̲S̲S̲

         Insertion of the pseudo MTCB in the LP queue:

         CC equal to completion code.



3.8.4    M̲T̲C̲B̲ ̲M̲o̲n̲i̲t̲o̲r̲

         -   create the pseudo MTCB,

         -   write log information on the pseudo MTCB, and

         -   release the pseudo MTCB:

             CC equal to completion code.



3.9      L̲I̲S̲T̲I̲N̲G̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲S̲

         Source listings and linker list may be obtained from
         the FIKS library (FIXLIB, ref. to SCCLDD).











                   4  Q̲U̲A̲L̲I̲T̲Y̲ ̲A̲S̲S̲U̲R̲A̲N̲C̲E̲



4.1      Q̲U̲A̲L̲I̲F̲I̲C̲A̲T̲I̲O̲N̲ ̲T̲E̲S̲T̲S̲

         The test of the procedure is described in ref. 9.



4.2      O̲T̲H̲E̲R̲ ̲Q̲U̲A̲L̲I̲T̲Y̲ ̲A̲S̲S̲U̲R̲A̲N̲C̲E̲ ̲P̲R̲O̲V̲I̲S̲I̲O̲N̲S̲

         Not applicable.





               5  P̲R̲E̲P̲A̲R̲A̲T̲I̲O̲N̲S̲ ̲F̲O̲R̲ ̲D̲E̲L̲I̲V̲E̲R̲Y̲

         Preparation of the binary object code starts with an
         editing of the source text.

         Then the source text is merged together with the prefix
         files:

         GENS.D * SWELLPREFIX.D * GENERALPARAMS.S
         …0e… ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲…0f… * IOSPARAMS.S
         …0e… ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲…0f… * MONITORNAMES.S
         …0e… ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲…0f… * KERNELPARAMS.S

         and

         FIX-PREFIX.D * CONFIG ̲TYPE.S
         …0e… ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲…0f… * FIX-MONITORNAMES.S
         …0e… ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲…0f… * QACCESS-TYPES.S
         …0e… ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲…0f… * AL-DT-PARAMS.S


         The merge file is compiled by running the SWELL compiler,
         and the listing is printed.

         The object code is then linked together with other
         pieces of object code by the LINKER.

         Finally the binary code may be installed.

         Exact instructions may be obtained from the file "INFORMATION"
         in the most recent ESP-directory of FIXLIB.