CAMPS
INSTALLATION
PROCEDURES
SITE 12…02……02…
CAMPS
5.9 P̲O̲W̲E̲R̲ ̲U̲P̲ ̲A̲N̲D̲ ̲C̲H̲E̲C̲K̲ ̲O̲U̲T̲
Before powering up, verify that a̲l̲l̲ ̲s̲w̲i̲t̲c̲h̲e̲s̲ on a̲l̲l̲
e̲q̲u̲i̲p̲m̲e̲n̲t̲ are i̲n̲ ̲p̲o̲s̲i̲t̲i̲o̲n̲ ̲o̲f̲f̲ or O.
5.9.1 G̲r̲o̲u̲n̲d̲i̲n̲g̲s̲
a) Measure with an Ohm-meter that no shor circuit
exists between the safety group (cabinets) and
the lines of circuit no. 1 through 9 and 1a through
3a.
b) Remount the lids of the power line filters by the
30 screws.
c) Measure with an Ohm-meter if the "Equipment Frame
Ground" (cabines) is isolated from the "Signal
Ground" (5V return).
The "Signal Ground" (GND) is found on the CCA-panel,
refer to Figure 5.9.1.
d) Start the powering up in the below sequence, starting
at the CAMPS power distribution board (PDB):
5.9.2 C̲A̲M̲S̲ ̲P̲D̲B̲
T̲U̲R̲N̲ ̲O̲N̲: Main circuit breaker
T̲U̲R̲N̲ ̲O̲N̲: Miniature circuit breakers
C̲H̲E̲C̲K̲O̲U̲T̲: No fuses in the CAMPS PDB blown due to
short circuit in the installation.
Figure 5.9.1
Front Layout for CCA