⟦c5a42bf57⟧ Wang Wps File

    Length: 72620 (0x11bac)
    Types: Wang Wps File
    Notes: CRT/TSS/001               
    Names: »1400A «

Derivation

└─⟦c9afadba6⟧ Bits:30006061 8" Wang WCS floppy, CR 0093A
    └─ ⟦this⟧ »1400A « 

WangText

…00……00……00…+…02…+
…00……00…+ +…07…*…0f…)…08…)…02…(…0c…(…02…(…06…'…0b…'…0d…'…05…&…0d…&…0f…&…05…%…0b…%…00…%…05…%…06…$…08…$…0a…$…0c…$…0e…$…05…#…0b…#…00…#
#…07…"…08…"…0c…"…0e…"…02…"
"…07…!…09…!…0d…!…0e…!…02…!  …08… …09… …0d……86…1         …02…   …02…   …02…   …02…                                           




…02…CRT/TSS/001

…02…GT/811123…02……02…
FACTORY ACCEPTANCE TEST SPECIFICATION
AND PROCEDURE…02…ISSUE 1…02…CRT














         811022                            All                   Original
                                                                 Issue
                                                                 of
                                                                 Document

Issue 1  811123              SHAPE tlx
               CAMPS log 408
               para. 1.c     14            Reference to power input
                                           removed.

               SHAPE tlx
               CAMPS log 408
               para. 1.a     18,           Simultaneous test of
                             22-24a,       8 channels
                             24b,
                             25-48,
                             50-52,
                             54-56,
                             58-60,
                             62-64,
                             66-68,
                             70-72,
                             74-76,
                             78-80,
                             82-84,
                             86-88,
                             90-92,
                             94-96,
                             98-101,
                             103-106,
                             108-121,
                             123-132,
                             134-137,
                             D1

               Clarifica-
               tion          A3-A13        Appendix A expanded.


                        T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲



   1  GENERAL .......................................
      7b

     1.1  PURPOSE ...................................
        7b
     1.2  REFERENCED DOCUMENTS ......................
        7b
     1.3  TERMS AND ABBREVIATIONS ...................
        7b

   2  REQUIREMENT MAPPING ...........................
      8

     2.1  VERIFICATION DEFINITIONS ..................
        8
       2.1.1  Examination/Inspection ................
          8
       2.1.2  Analysis ..............................
          8
       2.1.3  Test ..................................
          8

     2.2  VERIFICATION CLASSES ......................
        9
     2.3  FACTORY ACCEPTANCE TEST CROSS REFERENCE
          INDEX .....................................
          9

   3  TEST SPECIFICATION ............................
     13

     3.1  TEST PURPOSE ..............................
       13
     3.2  REQUIREMENTS ..............................
       13
     3.3  TEST METHODS AND CONTSTRAINTS .............
       14
       3.3.1  Test Drive System .....................
         14
       3.3.2  Test Constraints ......................
         15

     3.4  TEST OBJECT IDENTIFICATION ................
       15
     3.5  SUPPORTING EQUIPMENT ......................
       15
     3.6  TEST DESCRIPTION ..........................
       16
       3.6.1  Test Configuration Baselines ..........
         16
         3.6.1.1  Baseline I: CRT Link Without
                  Crypto/Modem ......................
                   16
         3.6.1.2  Baseline II: Crypto/Modem Link ....
           16
         3.6.1.3  Baseline III: CRT Link with 
                  Crypto/Modem ......................
                   16

       3.6.2  Testgroup Descriptions ................
         22
         3.6.2.1  Testgroup 1 .......................
           22
         3.6.2.2  Testgroup 2 .......................
           23



   4  TEST PROCEDURES ...............................
     24

     4.1  TESTGROUP 1 ...............................
       24
       4.1.1  Test of Site 2 Equipment ..............
         25
         4.1.1.1  Test Set-Up .......................
           25
         4.1.1.2  Test Initialization ...............
           25
         4.1.1.3  Test Steps ........................
           27
         4.1.1.4  Test Termination ..................
           28

       4.1.2  Test of Site 8 Equipment ..............
         29
         4.1.2.1  Test Set-Up .......................
           29
         4.1.2.2  Test Initialization ...............
           29
         4.1.2.3  Test Steps ........................
           31
         4.1.2.4  Test Termination ..................
           32

       4.1.3  Test of Site 14 Equipment .............
         33
         4.1.3.1  Test Set-Up .......................
           33
         4.1.3.2  Test Initialization ...............
           33
         4.1.3.3  Test Steps ........................
           35
         4.1.3.4  Test Termination ..................
           36

       4.1.4  Test of Site 9 Equipment ..............
         37
         4.1.4.1  Test Set-Up .......................
           37
         4.1.4.2  Test Initialization ...............
           37
         4.1.4.3  Test Steps ........................
           39
         4.1.4.4  Test Termination ..................
           40

       4.1.5  Test of Site 10 Equipment .............
         41
         4.1.5.1  Test Set-Up .......................
           41
         4.1.5.2  Test Initialization ...............
           41
         4.1.5.3  Test Steps ........................
           43
         4.1.5.4  Test Termination ..................
           44

       4.1.6  Test of Site 13 Equipment .............
         45
         4.1.6.1  Test Set-Up .......................
           45
         4.1.6.2  Test Initialization ...............
           45
         4.1.6.3  Test Steps ........................
           47
         4.1.6.4  Test Termination ..................
           48

       4.1.7  Test of Site 5A Equipment .............
         49
         4.1.7.1  Test Set-Up .......................
           49
         4.1.7.2  Test Initialization ...............
           49
         4.1.7.3  Test Steps ........................
           51
         4.1.7.4  Test Termination ..................
           52



       4.1.8  Test of Site 5B Equipment .............
         53
         4.1.8.1  Test Set-Up .......................
           53
         4.1.8.2  Test Initialization ...............
           53
         4.1.8.3  Test Steps ........................
           55
         4.1.8.4  Test Termination ..................
           56

       4.1.9  Test of Site 15A Equipment ............
         57
         4.1.9.1  Test Set-Up .......................
           57
         4.1.9.2  Test Initialization ...............
           57
         4.1.9.3  Test Steps ........................
           59
         4.1.9.4  Test Termination ..................
           60

       4.1.10 Test of Site 15B Equipment ............
         61
         4.1.10.1 Test Set-Up .......................
           61
         4.1.10.2 Test Initialization ...............
           61
         4.1.10.3 Test Steps ........................
           63
         4.1.10.4 Test Termination ..................
           64

       4.1.11 Test of Site 6A Equipment .............
         65
         4.1.11.1 Test Set-Up .......................
           65
         4.1.11.2 Test Initialization ...............
           65
         4.1.11.3 Test Steps ........................
           67
         4.1.11.4 Test Termination ..................
           68

       4.1.12 Test of Site 6B Equipment .............
         69
         4.1.12.1 Test Set-Up .......................
           69
         4.1.12.2 Test Initialization ...............
           69
         4.1.12.3 Test Steps ........................
           71
         4.1.12.4 Test Termination ..................
           72

       4.1.13 Test of Site 7A Equipment .............
         73
         4.1.13.1 Test Set-Up .......................
           73
         4.1.13.2 Test Initialization ...............
           73
         4.1.13.3 Test Steps ........................
           75
         4.1.13.4 Test Termination ..................
           76

       4.1.14 Test of Site 7B Equipment .............
         77
         4.1.14.1 Test Set-Up .......................
           77
         4.1.14.2 Test Initialization ...............
           77
         4.1.14.3 Test Steps ........................
           79
         4.1.14.4 Test Termination ..................
           80

       4.1.15 Test of Site 11A Equipment ............
         81
         4.1.15.1 Test Set-Up .......................
           81
         4.1.15.2 Test Initialization ...............
           81
         4.1.15.3 Test Steps ........................
           83
         4.1.15.4 Test Termination ..................
           84



       4.1.16 Test of Site 11B Equipment ............
         85
         4.1.16.1 Test Set-Up .......................
           85
         4.1.16.2 Test Initialization ...............
           85
         4.1.16.3 Test Steps ........................
           87
         4.1.16.4 Test Termination ..................
           88

       4.1.17 Test of Site 12A Equipment ............
         89
         4.1.17.1 Test Set-Up .......................
           89
         4.1.17.2 Test Initialization ...............
           89
         4.1.17.3 Test Steps ........................
           91
         4.1.17.4 Test Termination ..................
           92

       4.1.18 Test of Site 12B Equipment ............
         93
         4.1.18.1 Test Set-Up .......................
           93
         4.1.18.2 Test Initialization ...............
           93
         4.1.18.3 Test Steps ........................
           95
         4.1.18.4 Test Termination ..................
           96

       4.1.19 Test of Site 4A Equipment .............
         97
         4.1.19.1 Test Set-Up .......................
           97
         4.1.19.2 Test Initialization ...............
           97
         4.1.19.3 Test Steps ........................
          100
         4.1.19.4 Test Termination ..................
          101

       4.1.20 Test of Site 4B Equipment .............
        102
         4.1.20.1 Test Set-Up .......................
          102
         4.1.20.2 Test Initialization ...............
          102
         4.1.20.3 Test Steps ........................
          105
         4.1.20.4 Test Termination ..................
          106

       4.1.21 Test of Site 4C Equipment .............
        107
         4.1.21.1 Test Set-Up .......................
          107
         4.1.21.2 Test Initialization ...............
          107
         4.1.21.3 Test Steps ........................
          110
         4.1.21.4 Test Termination ..................
          111

       4.1.22 Test of Site 4D Equipment, Opto Lines .
        112
         4.1.22.1 Test Set-Up .......................
          112
         4.1.22.2 Test Initialization ...............
          112
         4.1.22.3 Test Steps ........................
          115
         4.1.22.4 Test Termination ..................
          116

       4.1.23 Test of Site 4D Equipment, V28 (L/L)
              Lines .................................
              117
         4.1.23.1 Test Set-Up .......................
          117
         4.1.23.2 Test Initialization ...............
          117
         4.1.23.3 Test Steps ........................
          120
         4.1.23.4 Test Termination ..................
          121



       4.1.24 Test of Site 4E Equipment .............
        122
         4.1.24.1 Test Set-Up .......................
          122
         4.1.24.2 Test Initialization ...............
          122
         4.1.24.3 Test Steps ........................
          125
         4.1.24.4 Test Termination ..................
          126

     4.2  TESTGROUP 2 ...............................
      127
       4.2.1  Test of Normal Connection to 8 Channels
        128
         4.2.1.1  Test Set-Up .......................
          128
         4.2.1.2  Test Initialization ...............
          128
         4.2.1.3  Test Steps ........................
          131
         4.2.1.4  Test Termination ..................
          132

       4.2.2  Test of Recovery from Transmission
              Errors ................................
              133
         4.2.2.1  Test Set-Up .......................
          133
         4.2.2.2  Test Initialization ...............
          133
         4.2.2.3  Test Steps ........................
          136
         4.2.2.4  Test Termination ..................
          137

   APPENDIX A .......................................
     A1
   APPENDIX B .......................................
     B1
   APPENDIX C .......................................
     C1
   APPENDIX E .......................................
     D1
   APPENDIX F .......................................
     D2


                        1̲ ̲ ̲G̲E̲N̲E̲R̲A̲L̲



1.1      P̲U̲R̲P̲O̲S̲E̲

         The purpose of this document is

         a)  To identify all requirements to be verified by
             test/demonstration during the Factory Acceptance
             Test (FAT)

         b)  To specify

             1)  Test methods

             2)  Test constraints

             3)  Test procedure, including specification of
                 required test equipment, test set-up, a step-by-step
                 procedure and expected test results



1.2      R̲E̲F̲E̲R̲E̲N̲C̲E̲D̲ ̲D̲O̲C̲U̲M̲E̲N̲T̲S̲

         a)  CRT/SDS/001
             CRT System Requirement and Design Specification

         b)  CPS/PLN/012
             CAMPS Acceptance Plan



1.3      T̲E̲R̲M̲S̲ ̲A̲N̲D̲ ̲A̲B̲B̲R̲E̲V̲I̲A̲T̲I̲O̲N̲S̲

         CAMPS   Computer Aided Message Processing System
         CRT     CAMPS Remote Terminals
         SDS     CRT System Requirement and Design Specification
         FAT     Factory Acceptance Test





                  2̲ ̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲ ̲M̲A̲P̲P̲I̲N̲G̲



         This section contains a listing of the CRT Requirements
         as stated in the requirement and design specification
         table of contents.

         For each of the listed requirements a cross reference
         is made indicating the planned verification method.

         The resulting mapping of stated requirements is used
         as basis for the elaboration of the Factory Acceptance
         Test Specifications.



2.1      V̲E̲R̲I̲F̲I̲C̲A̲T̲I̲O̲N̲ ̲D̲E̲F̲I̲N̲I̲T̲I̲O̲N̲S̲

         The following definitions apply for the planned verification
         methods:



2.1.1    E̲x̲a̲m̲i̲n̲a̲t̲i̲o̲n̲/̲I̲n̲s̲p̲e̲c̲t̲i̲o̲n̲

         This method is a non-functional verification, such
         as visual inspection of the physical characteristics
         of the item or of the documentation associated with
         the item.



2.1.2    A̲n̲a̲l̲y̲s̲i̲s̲

         This method is a non-functional verification, such
         as deduction or translation of data, review of analytical
         data, or performance of a detailed analysis.



2.1.3    T̲e̲s̲t̲

         This method is a functional verification, such as actual
         operation wherein the element of verification is instrumented,
         measured, or displayed directly.

         All hardware shall be tested to demonstrate its proper
         functioning, its interfaces and its performance.


2.2      V̲E̲R̲I̲F̲I̲C̲A̲T̲I̲O̲N̲ ̲C̲L̲A̲S̲S̲E̲S̲

         Tests to verify functional performance are class II
         (External verification).

         Analysis, examination and inspections are class I (Internal
         verifications).



2.3      F̲A̲C̲T̲O̲R̲Y̲ ̲A̲C̲C̲E̲P̲T̲A̲N̲C̲E̲ ̲T̲E̲S̲T̲ ̲C̲R̲O̲S̲S̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲ ̲I̲N̲D̲E̲X̲

         The mapping of the SDS requirements is found on the
         following pages.






                S̲D̲S̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲S̲

                T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲

                                                 N̲/̲A̲
 ̲ ̲E̲X̲A̲M̲ ̲ ̲A̲N̲A̲L̲ ̲ ̲T̲E̲S̲T̲

  3  REQUIREMENTS .............................
    3.1  SYSTEM DEFINITION ....................
      3.1.1  General Description ..............      X     X
      3.1.2  Functional Requirements ..........      X     X
        3.1.2.1  Remote Site Connections ......      X     X
        3.1.2.2  Main Site Connections ........      X     X

      3.1.3  Design Requirements ..............      X

    3.2  FUNCTIONAL PRINCIPLE .................
      3.2.1  Basic Configuration ..............      X
        3.2.1.1  Main Site Configuration ......            X     X
        3.2.1.2  Remote Site Configuration ....            X     X

      3.2.2  Reconfiguration Possibilities ....
        3.2.2.1  Option 1 .....................            X
        3.2.2.2  Option 2 .....................            X

      3.2.3  Interface Capability .............            X     X
      3.2.4  Specific Equipment Characteri-
             stics ............................
        3.2.4.1  Crypto/Modem .................      X
        3.2.4.2  Medium Speed Printers ........      X
        3.2.4.3  Visual Display Units .........      X

    3.3  PHYSICAL CHARACTERISTICS .............
      3.3.1  Power Input ......................            X
      3.3.2  Environmental Conditions ......... X
        3.3.2.1  Temperature and Humidity .....            X
        3.3.2.2  Dust and Fumes ...............            X

    3.4  SECURITY ............................. X
      3.4.1  TEMPEST Acceptance ...............      X

    3.5  CONSTRUCTION REQUIREMENTS ............  
      3.5.1  General .......................... X
        3.5.1.1  Equipment produced by 
                 Christian Rovsing A/S ........      X
        3.5.1.2  Equipment produced by
                 Subcontractors ...............      X
        3.5.1.3  Products from other Suppliers       X


                                                 N̲/̲A̲
 ̲ ̲E̲X̲A̲M̲ ̲ ̲A̲N̲A̲L̲ ̲ ̲T̲E̲S̲T̲

      3.5.2  Special Requirements for the
             CRT System ....................... X
        3.5.2.1  Utility Outlet Sockets ....... X
        3.5.2.2  Bench Handling ...............            X
        3.5.2.3  Wiring .......................      X
        3.5.2.4  Ventilation and Cooling ......      X
        3.5.2.5  Nameplates and Product
                 Marking ......................      X

    3.6  CRT DOCUMENTATION .................... X
      3.6.1  Headlines to the CRT Equipment
             Handbook ......................... X
      3.6.2  Contents of the CRT Equipment
             Handbook ......................... X
        3.6.2.1  Scope of Manual .............. X
        3.6.2.2  Introduction ................. X
        3.6.2.3  Specifications ............... X
        3.6.2.4  Connections .................. X
        3.6.2.5  Detailed Functional Descrip-
                 tion ......................... X
        3.6.2.6  Installation ................. X
        3.6.2.7  Operating Instructions ....... X
        3.6.2.8  Maintenance .................. X
        3.6.2.9  Assembly Breakdown ........... X
        3.6.2.10 Inventory .................... X
        3.6.2.11 Spare Parts List ............. X
        3.6.2.12 Circuit Boards and Diagrams .. X

        3.6.3  Field Modification Documents ... X

    3.7  LOGISTIC REQUIREMENTS ................
      3.7.1  Transportation and Installation ..
        3.7.1.1  Transportation ............... X
        3.7.1.2  Installation .................
          3.7.1.2.1  Equipment installation 
                     at main sites ............ X
          3.7.1.2.2  Equipment installation
                     at remote sites .......... X
          3.7.1.2.3  Standards and Security ... X
          3.7.1.2.4  Power Supply and Power
                     distribution ............. X
          3.7.1.2.5  Grounding ................ X
          3.7.1.2.6  Space and access ......... X
          3.7.1.2.7  Site Surveys ............. X



                                                 N̲/̲A̲
 ̲ ̲E̲X̲A̲M̲ ̲ ̲A̲N̲A̲L̲ ̲ ̲T̲E̲S̲T̲

      3.7.2  Maintenance and Support .......... X
      3.7.3  Spares and Codification ..........
        3.7.3.1  Supply of parts .............. X
        3.7.3.2  NATO Codification ............ X

      3.7.4  Training ......................... X



                  3̲ ̲ ̲T̲E̲S̲T̲ ̲S̲P̲E̲C̲I̲F̲I̲C̲A̲T̲I̲O̲N̲



3.1      T̲E̲S̲T̲ ̲P̲U̲R̲P̲O̲S̲E̲

         The purpose of the Factory Acceptance Test is to verify
         that all H/W comprising an integrated CRT configuration
         fulfils the functions requirements as stated in the
         SDS.

         The functional requirements which can be verified by
         test are subject to Factory Acceptance Test.



3.2      R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲S̲

         With reference to chapter 2, the functional requirements
         to be verified by test/demonstration are described
         in the SDS in:

         3.2.1.1 Main Site Configuration
         3.2.1.2 Remote Site Configuration
         3.2.3   Interface capability

         The functional requirements are divided into the following
         capabilities to be verified by the FAT:

         1)  I̲n̲t̲e̲r̲f̲a̲c̲e̲ ̲t̲o̲ ̲C̲A̲M̲P̲S̲ ̲T̲D̲X̲-̲B̲u̲s̲

             The ability to connect the CRT Main Site equipment
             to a TDX bus (simulating CAMPS TDX buses) and thus
             obtain communication with terminals connected to
             the Remote Site Equipment via the multiplexed link,
             shall be verified.

         2)  I̲n̲t̲e̲r̲f̲a̲c̲e̲ ̲t̲o̲ ̲V̲D̲U̲s̲ ̲a̲n̲d̲ ̲M̲S̲P̲s̲

             The ability to connect VDUs and/or MSPs to the
             V24 channels on remote site corresponding to the
             CRT-LTUXs shall be tested.

         3)  A̲u̲x̲i̲l̲i̲a̲r̲y̲ ̲a̲n̲d̲ ̲O̲C̲R̲ ̲C̲h̲a̲n̲n̲e̲l̲s̲

             The possibility of performing communication on
             the auxiliary V24 channels (the channels normally
             connected to CAMPS expansion LTUXs) shall be demonstrated.



             The same applies to the channel reserved for the
             future positioning of an OCR. Throughout this test
             specification and procedure, this channel is treated
             and nominated as an auxiliary channel

         4)  S̲t̲a̲t̲i̲s̲t̲i̲c̲a̲l̲ ̲M̲u̲l̲t̲i̲p̲l̲e̲x̲e̲r̲ ̲C̲o̲n̲t̲r̲o̲l̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲s̲

             This test shall verify the ability of the Statistical
             Multiplexer to:

             a)  perform traffic flow control to overcome a
                 data peak load effect

             b)  recover from a transmission error on the mux-line.

         5)  I̲n̲t̲e̲r̲f̲a̲c̲e̲ ̲t̲o̲ ̲C̲r̲y̲p̲t̲o̲/̲M̲o̲d̲e̲m̲

             Provided the cryptos and modems are available,
             the ability to perform the mux-line communication
             via a Crypto/Modem link shall be demonstrated.



3.3      T̲E̲S̲T̲ ̲M̲E̲T̲H̲O̲D̲S̲ ̲A̲N̲D̲ ̲C̲O̲N̲S̲T̲R̲A̲I̲N̲T̲S̲

         The functional characteristics of the CRT H/W will
         be checked by aid of a Test Drive System executing
         the necessary test drive software. The verification
         of the requirements is accomplished by successful execution
         of the test drive software.



3.3.1    T̲e̲s̲t̲ ̲D̲r̲i̲v̲e̲ ̲S̲y̲s̲t̲e̲m̲

         A special Test Drive System will be set up to simulate
         the interface to CAMPS via the TDX Bus.

         The Test Drive System is based on a CR80S computer
         system with interface to a single TDX-BUS. The TDX-Controller
         is also part of the Test Drive System. For a detailed
         description of the Test Drive System, refer to Appendix
         A.





3.3.2    T̲e̲s̲t̲ ̲C̲o̲n̲s̲t̲r̲a̲i̲n̲t̲s̲

         1)  As the Test Drive System only will support a single
             TDX-Bus, the selection of active TDX-Bus for the
             CRT system will be performed manually by having
             the Mode select switch on the front panel of the
             BSM-X in position Manual.

         2)  The firmware used in the LTUX-Ss under test is
             a preliminary version.



3.4      T̲E̲S̲T̲ ̲O̲B̲J̲E̲C̲T̲ ̲I̲D̲E̲N̲T̲I̲F̲I̲C̲A̲T̲I̲O̲N̲

         Each set of Remote Site equipment together with the
         associated Main Site equipment forms a H/W configuration,
         in the following referred to as a site configuration.
         The test verifying the interface to CAMPS TDX-bus,
         Crypto/Modem and terminals, and the ability of the
         Stat. Mux. to perform traffic flow control will be
         conducted for each individual site configuration.

         The tests to verify the communication on the Auxiliary
         channels and the ability of Statistical Multiplexer
         to recover from transmission errors will only be conducted
         to a single site configuration.



3.5      S̲U̲P̲P̲O̲R̲T̲I̲N̲G̲ ̲E̲Q̲U̲I̲P̲M̲E̲N̲T̲

         The Test Drive system is described in Appendix A.

         The Terminal Equipment is described in Appendix B.

         The Interface Equipmnt is described in Appendix C.





3.6      T̲E̲S̲T̲ ̲D̲E̲S̲C̲R̲I̲P̲T̲I̲O̲N̲



3.6.1    T̲e̲s̲t̲ ̲C̲o̲n̲f̲i̲g̲u̲r̲a̲t̲i̲o̲n̲ ̲B̲a̲s̲e̲l̲i̲n̲e̲s̲

         For the purpose of this test, 3 different test configuration
         baselines are defined:

         I   CRT link without Crypto/Modem
         II  Crypto/Modem link
         III CRT link with Crypto/Modem.

         The baselines are depicted in figure 3.6-1.



3.6.1.1  B̲a̲s̲e̲l̲i̲n̲e̲ ̲I̲:̲ ̲C̲R̲T̲ ̲L̲i̲n̲k̲ ̲W̲i̲t̲h̲o̲u̲t̲ ̲C̲r̲y̲p̲t̲o̲/̲M̲o̲d̲e̲m̲

         Baseline I is used for preliminary tests to verify
         the CRT equipment.

         It will also be used during the Factory Acceptance
         Test if the Crypto or Modem equipment is unavailable.



3.6.1.2  B̲a̲s̲e̲l̲i̲n̲e̲ ̲I̲I̲:̲ ̲C̲r̲y̲p̲t̲o̲/̲M̲o̲d̲e̲m̲ ̲L̲i̲n̲k̲

         Baseline II is used to verify the crypto and modem
         equipment prior to integration with CRT equipment.

         CR is not responsible for verification of Crypto and
         Modem Equipment.



3.6.1.3  B̲a̲s̲e̲l̲i̲n̲e̲ ̲I̲I̲I̲:̲ ̲C̲R̲T̲ ̲L̲i̲n̲k̲ ̲w̲i̲t̲h̲ ̲C̲r̲y̲p̲t̲o̲/̲M̲o̲d̲e̲m̲

         Baseline III will be used for the Factory Acceptance
         Test unless the Crypto or Modem equipment is unavailable.

         In case an error is detected during the test, baseline
         III will be split into baselines I and II to locate
         the error.


















































      TEST CONFIGURATION BASELINE I AND III, OVERALL
              …01…FIGURE 3.6-1   (SHEET 1 OF 5)
      TEST CONFIGURATION FOR FACTORY ACCEPTANCE TEST











































         Equipment marked with $ is supporting equipment

         Equipment marked with * is not used during the test.

TEST CONFIGURATION BASELINE I AND III; MAIN SITE EQUIPMENT…01…

              FIGURE 3.6-1   (SHEET 2 OF 5)
      TEST CONFIGURATION FOR FACTORY ACCEPTANCE TEST















































…01…TEST CONFIGURATION BASELINE I AND III, REMOTE SITE EQUIPMENT
              …01…FIGURE 3.6-1   (SHEET 3 OF 5)
      TEST CONFIGURATION FOR FACTORY ACCEPTANCE TEST









































         Note:   The mode selection switches in the Stat. Mux.
                 shall be set to utilize V24 circuit 113 instead
                 of circuit 114. Otherwise an external clock
                 generator shall be used to generate clocksignal
                 for circuits 114 and 115.

   …01…TEST CONFIGURATION BASELINE I, INTERFACE EQUIPMENT
              …01…FIGURE 3.6-1  (SHEET 4 OF 5)
      TEST CONFIGURATION FOR FACTORY ACCEPTANCE TEST

















































TEST CONFIGURATION BASELINE II (AND II), INTERFACE EQUIPMENT
              …01…FIGURE 3.6-1   (SHEET 5 OF 5)
      TEST CONFIGURATION FOR FACTORY ACCEPTANCE TEST


3.6.2    T̲e̲s̲t̲g̲r̲o̲u̲p̲ ̲D̲e̲s̲c̲r̲i̲p̲t̲i̲o̲n̲s̲

         The tests to be performed at the FAT are divided in
         2 testgroups. Within each testgroup, the wiring of
         the CRT equipment and the nubmer of connected VDUs
         and MSPs is not changed.



3.6.2.1  T̲e̲s̲t̲g̲r̲o̲u̲p̲ ̲1̲

         The tests performed in this testgroup will give a verification
         of the interface to the TDX-bus and to the number of
         terminals which will communicate with the CRT-LTUXs
         (ref. CRT/SDS/001) the interface to Crypto/Modem and
         the ability of the Stat. Mux. to perform flow control
         and to multiplex/demultiplex 8 V24 channels. 6 VDUs
         and 2 MSPs will be used for connection to the remote
         site equipment. For all the VDUs it shall be verified
         that data can be transferred to and from the VDU. For
         the MSPs, data will only be transmitted to the MSP.
         It is verified that all data are transmitted to/from
         the terminals even in a peak load situation.  To be
         able to support the auxillary V24 channels, an additional
         LTUX will be used together with the main site equipment,
         for sites where only one LTUX is provided. For sites
         where more than one LTUX is provided, the LTUX not
         subject to test will be used as supporting equipment.

         a)  T̲e̲s̲t̲ ̲C̲o̲n̲t̲r̲o̲l̲

             The tests are initiated on the terminal attached
             to the test drive system. The test program controls
             the execution of the test.

         b)  I̲n̲p̲u̲t̲ ̲D̲a̲t̲a̲

             Input data is supplied by the test drive system.

         c)  I̲n̲p̲u̲t̲ ̲C̲o̲m̲m̲a̲n̲d̲s̲

             The test drive system will supply the commands,
             necessary to control the terminals.



         d)  O̲u̲t̲p̲u̲t̲ ̲D̲a̲t̲a̲

             Output data to the terminals will be visualized
             on the terminals. Data returned from a VDU will
             be compared with the expected data in the test
             drive system.

         e)  T̲e̲s̲t̲ ̲S̲t̲a̲t̲u̲s̲

             The current Test Status will be printed on the
             terminal attached to the test drive system.



3.6.2.2  T̲e̲s̲t̲g̲r̲o̲u̲p̲ ̲2̲

         The tests performed in this testgroup will give a verification
         of the ability of the Statistical Multiplexer to recover
         from a transmission error. By a short disconnection
         of the mux-line it is verified that the Stat. Mux.
         can recover from a transmission error.

         a)  T̲e̲s̲t̲ ̲C̲o̲n̲t̲r̲o̲l̲

             The tests are initiated on the terminal attached
             to the test drive system. The test program controls
             the execution of the test.

         b)  I̲n̲p̲u̲t̲ ̲D̲a̲t̲a̲

             Input data is supplied by the test drive system.

         c)  I̲n̲p̲u̲t̲ ̲C̲o̲m̲m̲a̲n̲d̲s̲

             The test drive system will supply the commands
             necessary to control the terminals.

         d)  O̲u̲t̲p̲u̲t̲ ̲D̲a̲t̲a̲

             Output data to the terminals will be visualized
             on the terminals. Data returned from a VDU will
             be compared with the expected data in the test
             drive system.

         e)  T̲e̲s̲t̲ ̲S̲t̲a̲t̲u̲s̲

             The current test status will be printed on the
             terminal attached to the test drive system.


                    4̲ ̲ ̲T̲E̲S̲T̲ ̲P̲R̲O̲C̲E̲D̲U̲R̲E̲S̲



4.1      T̲E̲S̲T̲G̲R̲O̲U̲P̲ ̲1̲

         The tests within this testgroup are performed for each
         set of Remote Site equipment together with its associated
         Main Site equipment.

         Several CRT H/W capabilities are demonstrated by the
         single tests, due to the configuration.

         With reference to the SDS, the following capabilities
         of the Main Site Configuration (SDS para. 3.2.1.1)
         are demonstrated.

         1)  Point a:        Connection to TDX bus

             Reason:         The Test Drive System is connected
                             via a TDX bus.

         2)  Point b and c1: Channel multiplexing of 8 V24 channels.

             Reason:         The 8 V24 channels are transmited
                             on a single mux-line.

         3)  Point c3:       Traffic flow control

             Reason:         The amount of data transmitted
                             from the LTUX, if traffic flow
                             control was not performed, exceeds
                             the amount of data which can be
                             transmitted on the mux-line or
                             buffered in the Stat. Mux.

         The following capabilities of the Remote Site Configuration
         (SDS para 3.2.1.2) are demonstrated:

         1)  Point b:        Channel demultiplexing of 8 V24
                             channels.

             Reason:         Data received on the single mux-line
                             are transmitted to 8 terminals.



         The following Interface Capabilities (SDS para. 3.2.3)
         are demonstrated:

         1)  VDUs with OPTO-interface

             Reason:         4 VDUs with opto interface are
                             connected to the Remote Site Equipment.

         2)  VDUs and MSPs with V28 interface

             Reason:         2 VDUs and 2 MSPs are connected
                             to the auxillary channels at Remote
                             Site.

         3)  Auxillary channels

             Reason:         A supporting LTUX supplies data
                             to the auxillary channels at Main
                             Site and Terminals are connected
                             at Remote Site.

         4)  Crypto/Modem

             Reason:         The crypto is used for he mux-line
                             communication, if available.





4.1.1    T̲e̲s̲t̲ ̲o̲f̲ ̲S̲i̲t̲e̲ ̲2̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲



4.1.1.1  T̲e̲s̲t̲ ̲S̲e̲t̲-̲U̲p̲

         1   Connect the equipment under test with the supporting
             equipment as shown in figure 4.1.1-1.

         2.1 Check the LTUX-S configuration. The correct configuration
             is described in Appendix A para. 3.1.1.

             The device number of the LTUX-S under test shall
             be 13…0f…H…0e…. The supporting LTUX-S shall be set to 14…0f…H…0e….

         2.2 Check that the Stat. Mux. configuration is in accordance
             with the description of Appendix E.

         3   Set the Mode select switch on the BSM-X to "MAN"
             and the Bus select switch to "1".

         4   Turn power on supporting equipment.

         5   Turn power on equipment under test.

         6   Boot test drive system as described in Appendix
             F, part I.



4.1.1.2  T̲e̲s̲t̲ ̲I̲n̲i̲t̲i̲a̲l̲i̲z̲a̲t̲i̲o̲n̲

         Perform initialization as described in Appendix F,
         Part II.























































         FIGURE 4.1.1-1…01…TEST CONFIGURATION SITE 2


4.1.1.3  T̲e̲s̲t̲ ̲S̲t̲e̲p̲s̲


                                        G̲R̲O̲U̲P̲/̲T̲E̲S̲T̲ ̲N̲O̲.̲:̲ 1/1


         F̲U̲N̲C̲T̲I̲O̲N̲:̲      Interface to TDX-bus, CRT channels,
                        and Crypto/Modem, and Stat. Mux. Multiplexing
                        Traffic flow control

         R̲E̲F̲.̲ ̲S̲D̲S̲ ̲P̲A̲R̲A̲:̲ 3.2.1.1, 3.2.1.2, and 3.2.3

         D̲A̲T̲E̲:̲

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         PROC.   ACTION                 EXPECTED RESULT
         STEP
         NO.
          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         1       Start up the test by   Print out on the Line
                 writing:               Pinter identical with
                 DO DELTA.TEST ̲4  CR    the print out in Appendix
                 on the console         D, apart from the time
                                        indication


            COMMENTS













                                                 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                                TEST WITNESSES


                                               ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                        ̲ ̲ ̲ ̲ ̲ ̲
                                                 TEST QA GQAR




4.1.1.4  T̲e̲s̲t̲ ̲T̲e̲r̲m̲i̲n̲a̲t̲i̲o̲n̲

         1   When the line printer connected to the test drive
             system has stopped, the print out is ready for
             comparison with the listing of Appendix D.

         2   Close-down by

         2.1 Remove the discettes from the floppy-drive.

         2.2 Turn power off the equipment under test.

         2.3 Turn power off the supporting equipment.



4.1.2    T̲e̲s̲t̲ ̲o̲f̲ ̲S̲i̲t̲e̲ ̲8̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲



4.1.2.1  T̲e̲s̲t̲ ̲S̲e̲t̲-̲U̲p̲

         1   Connect the equipment under test with the supporting
             equipment as shown in figure 4.1.2-1.

         2.1 Check the LTUX-S configuration. The correct configuration
             is described in Appendix A para. 3.1.1.

             The device number of the LTUX-S under test shall
             be 13…0f…H…0e…. The supporting LTUX-S shall be set to 14…0f…H…0e….

         2.2 Check that the Stat. Mux. configuration is in accordance
             with the description of Appendix E.

         3   Set the Mode select switch on the BSM-X to "MAN"
             and the Bus select switch to "1".

         4   Turn power on supporting equipment.

         5   Turn power on equipment under test.

         6   Boot test drive system as described in Appendix
             F, part I.



4.1.2.2  T̲e̲s̲t̲ ̲I̲n̲i̲t̲i̲a̲l̲i̲z̲a̲t̲i̲o̲n̲

         Perform initialization as described in Appendix F,
         Part II.





















































         FIGURE 4.1.2-1…01…TEST CONFIGURATION SITE 8


4.1.2.3  T̲e̲s̲t̲ ̲S̲t̲e̲p̲s̲


                                        G̲R̲O̲U̲P̲/̲T̲E̲S̲T̲ ̲N̲O̲.̲:̲ 1/2


         F̲U̲N̲C̲T̲I̲O̲N̲:̲      Interface to TDX-bus, CRT channels,
                        and Crypto/Modem, and Stat. Mux. Multiplexing
                        Traffic flow control

         R̲E̲F̲.̲ ̲S̲D̲S̲ ̲P̲A̲R̲A̲:̲ 3.2.1.1, 3.2.1.2, and 3.2.3

         D̲A̲T̲E̲:̲

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         PROC.   ACTION                 EXPECTED RESULT
         STEP
         NO.
          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         1       Start up the test by   Print out on the Line
                 writing:               Pinter identical with
                 DO DELTA.TEST ̲4  CR    the print out in Appendix
                 on the console         D, apart from the time
                                        indication


            COMMENTS













                                                 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                                TEST WITNESSES


                                               ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                        ̲ ̲ ̲ ̲ ̲ ̲
                                                 TEST QA GQAR




4.1.2.4  T̲e̲s̲t̲ ̲T̲e̲r̲m̲i̲n̲a̲t̲i̲o̲n̲

         1   When the line printer connected to the test drive
             system has stopped, the print out is ready for
             comparison with the listing of Appendix D.

         2   Close-down by

         2.1 Remove the discettes from the floppy-drive.

         2.2 Turn power off the equipment under test.

         2.3 Turn power off the supporting equipment.



4.1.3    T̲e̲s̲t̲ ̲o̲f̲ ̲S̲i̲t̲e̲ ̲1̲4̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲



4.1.3.1  T̲e̲s̲t̲ ̲S̲e̲t̲-̲U̲p̲

         1   Connect the equipment under test with the supporting
             equipment as shown in figure 4.1.3-1.

         2.1 Check the LTUX-S configuration. The correct configuration
             is described in Appendix A para. 3.1.1.

             The device number of the LTUX-S under test shall
             be 13…0f…H…0e…. The supporting LTUX-S shall be set to 14…0f…H…0e….

         2.2 Check that the Stat. Mux. configuration is in accordance
             with the description of Appendix E.

         3   Set the Mode select switch on the BSM-X to "MAN"
             and the Bus select switch to "1".

         4   Turn power on supporting equipment.

         5   Turn power on equipment under test.

         6   Boot test drive system as described in Appendix
             F, part I.



4.1.3.2  T̲e̲s̲t̲ ̲I̲n̲i̲t̲i̲a̲l̲i̲z̲a̲t̲i̲o̲n̲

         Perform initialization as described in Appendix F,
         Part II.





















































        FIGURE 4.1.3-1…01…TEST CONFIGURATION SITE 14


4.1.3.3  T̲e̲s̲t̲ ̲S̲t̲e̲p̲s̲


                                        G̲R̲O̲U̲P̲/̲T̲E̲S̲T̲ ̲N̲O̲.̲:̲ 1/3


         F̲U̲N̲C̲T̲I̲O̲N̲:̲      Interface to TDX-bus, CRT channels,
                        and Crypto/Modem, and Stat. Mux. Multiplexing
                        Traffic flow control

         R̲E̲F̲.̲ ̲S̲D̲S̲ ̲P̲A̲R̲A̲:̲ 3.2.1.1, 3.2.1.2, and 3.2.3

         D̲A̲T̲E̲:̲

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         PROC.   ACTION                 EXPECTED RESULT
         STEP
         NO.
          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         1       Start up the test by   Print out on the Line
                 writing:               Pinter identical with
                 DO DELTA.TEST ̲4  CR    the print out in Appendix
                 on the console         D, apart from the time
                                        indication


            COMMENTS













                                                 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                                TEST WITNESSES


                                               ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                        ̲ ̲ ̲ ̲ ̲ ̲
                                                 TEST QA GQAR




4.1.3.4  T̲e̲s̲t̲ ̲T̲e̲r̲m̲i̲n̲a̲t̲i̲o̲n̲

         1   When the line printer connected to the test drive
             system has stopped, the print out is ready for
             comparison with the listing of Appendix D.

         2   Close-down by

         2.1 Remove the discettes from the floppy-drive.

         2.2 Turn power off the equipment under test.

         2.3 Turn power off the supporting equipment.



4.1.4    T̲e̲s̲t̲ ̲o̲f̲ ̲S̲i̲t̲e̲ ̲9̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲



4.1.4.1  T̲e̲s̲t̲ ̲S̲e̲t̲-̲U̲p̲

         1   Connect the equipment under test with the supporting
             equipment as shown in figure 4.1.4-1.

         2.1 Check the LTUX-S configuration. The correct configuration
             is described in Appendix A para. 3.1.1.

             The device number of the LTUX-S under test shall
             be 13…0f…H…0e…. The supporting LTUX-S shall be set to 14…0f…H…0e….

         2.2 Check that the Stat. Mux. configuration is in accordance
             with the description of Appendix E.

         3   Set the Mode select switch on the BSM-X to "MAN"
             and the Bus select switch to "1".

         4   Turn power on supporting equipment.

         5   Turn power on equipment under test.

         6   Boot test drive system as described in Appendix
             F, part I.



4.1.4.2  T̲e̲s̲t̲ ̲I̲n̲i̲t̲i̲a̲l̲i̲z̲a̲t̲i̲o̲n̲

         Perform initialization as described in Appendix F,
         Part II.





















































         FIGURE 4.1.4-1…01…TEST CONFIGURATION SITE 9


4.1.4.3  T̲e̲s̲t̲ ̲S̲t̲e̲p̲s̲


                                        G̲R̲O̲U̲P̲/̲T̲E̲S̲T̲ ̲N̲O̲.̲:̲ 1/4


         F̲U̲N̲C̲T̲I̲O̲N̲:̲      Interface to TDX-bus, CRT channels,
                        and Crypto/Modem, and Stat. Mux. Multiplexing
                        Traffic flow control

         R̲E̲F̲.̲ ̲S̲D̲S̲ ̲P̲A̲R̲A̲:̲ 3.2.1.1, 3.2.1.2, and 3.2.3

         D̲A̲T̲E̲:̲

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         PROC.   ACTION                 EXPECTED RESULT
         STEP
         NO.
          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         1       Start up the test by   Print out on the Line
                 writing:               Pinter identical with
                 DO DELTA.TEST ̲4  CR    the print out in Appendix
                 on the console         D, apart from the time
                                        indication


            COMMENTS













                                                 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                                TEST WITNESSES


                                               ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                        ̲ ̲ ̲ ̲ ̲ ̲
                                                 TEST QA GQAR




4.1.4.4  T̲e̲s̲t̲ ̲T̲e̲r̲m̲i̲n̲a̲t̲i̲o̲n̲

         1   When the line printer connected to the test drive
             system has stopped, the print out is ready for
             comparison with the listing of Appendix D.

         2   Close-down by

         2.1 Remove the discettes from the floppy-drive.

         2.2 Turn power off the equipment under test.

         2.3 Turn power off the supporting equipment.



4.1.5    T̲e̲s̲t̲ ̲o̲f̲ ̲S̲i̲t̲e̲ ̲1̲0̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲



4.1.5.1  T̲e̲s̲t̲ ̲S̲e̲t̲-̲U̲p̲

         1.1 Connect the Power Line Transformator input to 220V/50Hz
             and adjust to 240V + 1%/-1% output.

         1.2 Connect the equipment under test with the supporting
             equipment as shown in figure 4.1.5-1.

         2.1 Check the LTUX-S configuration. The correct configuration
             is described in Appendix A para. 3.1.1.

             The device number of the LTUX-S under test shall
             be 13…0f…H…0e…. The supporting LTUX-S shall be set to 14…0f…H…0e….

         2.2 Check that the Stat. Mux. configuration is in accordance
             with the description of Appendix E.

         3   Set the Mode select switch on the BSM-X to "MAN"
             and the Bus select switch to "1".

         4   Turn power on supporting equipment.

         5   Turn power on equipment under test.

         6   Boot test drive system as described in Appendix
             F, part I.



4.1.5.2  T̲e̲s̲t̲ ̲I̲n̲i̲t̲i̲a̲l̲i̲z̲a̲t̲i̲o̲n̲

         Perform initialization as described in Appendix F,
         Part II.





















































        FIGURE 4.1.5-1…01…TEST CONFIGURATION SITE 10


4.1.5.3  T̲e̲s̲t̲ ̲S̲t̲e̲p̲s̲


                                        G̲R̲O̲U̲P̲/̲T̲E̲S̲T̲ ̲N̲O̲.̲:̲ 1/5


         F̲U̲N̲C̲T̲I̲O̲N̲:̲      Interface to TDX-bus, CRT channels,
                        and Crypto/Modem, and Stat. Mux. Multiplexing
                        Traffic flow control

         R̲E̲F̲.̲ ̲S̲D̲S̲ ̲P̲A̲R̲A̲:̲ 3.2.1.1, 3.2.1.2, and 3.2.3

         D̲A̲T̲E̲:̲

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         PROC.   ACTION                 EXPECTED RESULT
         STEP
         NO.
          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         1       Start up the test by   Print out on the Line
                 writing:               Pinter identical with
                 DO DELTA.TEST ̲4  CR    the print out in Appendix
                 on the console         D, apart from the time
                                        indication


            COMMENTS













                                                 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                                TEST WITNESSES


                                               ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                        ̲ ̲ ̲ ̲ ̲ ̲
                                                 TEST QA GQAR




4.1.5.4  T̲e̲s̲t̲ ̲T̲e̲r̲m̲i̲n̲a̲t̲i̲o̲n̲

         1   When the line printer connected to the test drive
             system has stopped, the print out is ready for
             comparison with the listing of Appendix D.

         2   Close-down by

         2.1 Remove the discettes from the floppy-drive.

         2.2 Turn power off the equipment under test.

         2.3 Turn power off the supporting equipment.



4.1.6    T̲e̲s̲t̲ ̲o̲f̲ ̲S̲i̲t̲e̲ ̲1̲3̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲



4.1.6.1  T̲e̲s̲t̲ ̲S̲e̲t̲-̲U̲p̲

         1   Connect the equipment under test with the supporting
             equipment as shown in figure 4.1.6-1.

         2.1 Check the LTUX-S configuration. The correct configuration
             is described in Appendix A para. 3.1.1.

             The device number of the LTUX-S under test shall
             be 13…0f…H…0e…. The supporting LTUX-S shall be set to 14…0f…H…0e….

         2.2 Check that the Stat. Mux. configuration is in accordance
             with the description of Appendix E.

         3   Set the Mode select switch on the BSM-X to "MAN"
             and the Bus select switch to "1".

         4   Turn power on supporting equipment.

         5   Turn power on equipment under test.

         6   Boot test drive system as described in Appendix
             F, part I.



4.1.6.2  T̲e̲s̲t̲ ̲I̲n̲i̲t̲i̲a̲l̲i̲z̲a̲t̲i̲o̲n̲

         Perform initialization as described in Appendix F,
         Part II.





















































        FIGURE 4.1.6-1…01…TEST CONFIGURATION SITE 13


4.1.6.3  T̲e̲s̲t̲ ̲S̲t̲e̲p̲s̲


                                        G̲R̲O̲U̲P̲/̲T̲E̲S̲T̲ ̲N̲O̲.̲:̲ 1/6


         F̲U̲N̲C̲T̲I̲O̲N̲:̲      Interface to TDX-bus, CRT channels,
                        and Crypto/Modem, and Stat. Mux. Multiplexing
                        Traffic flow control

         R̲E̲F̲.̲ ̲S̲D̲S̲ ̲P̲A̲R̲A̲:̲ 3.2.1.1, 3.2.1.2, and 3.2.3

         D̲A̲T̲E̲:̲

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         PROC.   ACTION                 EXPECTED RESULT
         STEP
         NO.
          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         1       Start up the test by   Print out on the Line
                 writing:               Pinter identical with
                 DO DELTA.TEST ̲4  CR    the print out in Appendix
                 on the console         D, apart from the time
                                        indication


            COMMENTS













                                                 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                                TEST WITNESSES


                                               ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                        ̲ ̲ ̲ ̲ ̲ ̲
                                                 TEST QA GQAR




4.1.6.4  T̲e̲s̲t̲ ̲T̲e̲r̲m̲i̲n̲a̲t̲i̲o̲n̲

         1   When the line printer connected to the test drive
             system has stopped, the print out is ready for
             comparison with the listing of Appendix D.

         2   Close-down by

         2.1 Remove the discettes from the floppy-drive.

         2.2 Turn power off the equipment under test.

         2.3 Turn power off the supporting equipment.



4.1.7    T̲e̲s̲t̲ ̲o̲f̲ ̲S̲i̲t̲e̲ ̲5̲A̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲



4.1.7.1  T̲e̲s̲t̲ ̲S̲e̲t̲-̲U̲p̲

         1   Connect the equipment under test with the supporting
             equipment as shown in figure 4.1.7-1.

         2.1 Check the LTUX-S configuration. The correct configuration
             is described in Appendix A para. 3.1.1.

             The device no. of LTUX-S no. 1 shall be set to
             13…0f…H…0e… and for LTUX-S no. 2 to 14…0f…H…0e….

         2.2 Check that the Stat. Mux. configuration is in accordance
             with the description of Appendix E.

         3   Set the Mode select switch on the BSM-X to "MAN"
             and the Bus select switch to "1".

         4   Turn power on supporting equipment.

         5   Turn power on equipment under test.

         6   Boot test drive system as described in Appendix
             F, part I.



4.1.7.2  T̲e̲s̲t̲ ̲I̲n̲i̲t̲i̲a̲l̲i̲z̲a̲t̲i̲o̲n̲

         Perform initialization as described in Appendix F,
         Part II.






















































         FIGURE 4.1.7-1                                           TEST
                                                                  CONFIGURATION
                                                                  SITE
                                                                  5A


4.1.7.3  T̲e̲s̲t̲ ̲S̲t̲e̲p̲s̲


                                        G̲R̲O̲U̲P̲/̲T̲E̲S̲T̲ ̲N̲O̲.̲:̲ 1/7


         F̲U̲N̲C̲T̲I̲O̲N̲:̲      Interface to TDX-bus, CRT channels,
                        and Crypto/Modem, and Stat. Mux. Multiplexing
                        Traffic flow control

         R̲E̲F̲.̲ ̲S̲D̲S̲ ̲P̲A̲R̲A̲:̲ 3.2.1.1, 3.2.1.2, and 3.2.3

         D̲A̲T̲E̲:̲

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         PROC.   ACTION                 EXPECTED RESULT
         STEP
         NO.
          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         1       Start up the test by   Print out on the Line
                 writing:               Pinter identical with
                 DO DELTA.TEST ̲4  CR    the print out in Appendix
                 on the console         D, apart from the time
                                        indication


            COMMENTS













                                                 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                                TEST WITNESSES


                                               ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                        ̲ ̲ ̲ ̲ ̲ ̲
                                                 TEST QA GQAR




4.1.7.4  T̲e̲s̲t̲ ̲T̲e̲r̲m̲i̲n̲a̲t̲i̲o̲n̲

         1   When the line printer connected to the test drive
             system has stopped, the print out is ready for
             comparison with the listing of Appendix D.

         2   Close-down by

         2.1 Remove the discettes from the floppy-drive.

         2.2 Turn power off the equipment under test.

         2.3 Turn power off the supporting equipment.



4.1.8    T̲e̲s̲t̲ ̲o̲f̲ ̲S̲i̲t̲e̲ ̲5̲B̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲



4.1.8.1  T̲e̲s̲t̲ ̲S̲e̲t̲-̲U̲p̲

         1   Connect the equipment under test with the supporting
             equipment as shown in figure 4.1.8-1.

         2.1 Check the LTUX-S configuration. The correct configuration
             is described in Appendix A para. 3.1.1.

             The device no. of LTUX-S no. 1 shall be set to
             14…0f…H…0e… and for LTUX-S no. 2 to 13…0f…H…0e….

         2.2 Check that the Stat. Mux. configuration is in accordance
             with the description of Appendix E.

         3   Set the Mode select switch on the BSM-X to "MAN"
             and the Bus select switch to "1".

         4   Turn power on supporting equipment.

         5   Turn power on equipment under test.

         6   Boot test drive system as described in Appendix
             F, part I.



4.1.8.2  T̲e̲s̲t̲ ̲I̲n̲i̲t̲i̲a̲l̲i̲z̲a̲t̲i̲o̲n̲

         Perform initialization as described in Appendix F,
         Part II.






















































         FIGURE 4.1.8-1                                           TEST
                                                                  CONFIGURATION
                                                                  SITE
                                                                  5B


4.1.8.3  T̲e̲s̲t̲ ̲S̲t̲e̲p̲s̲


                                        G̲R̲O̲U̲P̲/̲T̲E̲S̲T̲ ̲N̲O̲.̲:̲ 1/8


         F̲U̲N̲C̲T̲I̲O̲N̲:̲      Interface to TDX-bus, CRT channels,
                        and Crypto/Modem, and Stat. Mux. Multiplexing
                        Traffic flow control

         R̲E̲F̲.̲ ̲S̲D̲S̲ ̲P̲A̲R̲A̲:̲ 3.2.1.1, 3.2.1.2, and 3.2.3

         D̲A̲T̲E̲:̲

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         PROC.   ACTION                 EXPECTED RESULT
         STEP
         NO.
          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         1       Start up the test by   Print out on the Line
                 writing:               Pinter identical with
                 DO DELTA.TEST ̲4  CR    the print out in Appendix
                 on the console         D, apart from the time
                                        indication


            COMMENTS













                                                 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                                TEST WITNESSES


                                               ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                        ̲ ̲ ̲ ̲ ̲ ̲
                                                 TEST QA GQAR




4.1.8.4  T̲e̲s̲t̲ ̲T̲e̲r̲m̲i̲n̲a̲t̲i̲o̲n̲

         1   When the line printer connected to the test drive
             system has stopped, the print out is ready for
             comparison with the listing of Appendix D.

         2   Close-down by

         2.1 Remove the discettes from the floppy-drive.

         2.2 Turn power off the equipment under test.

         2.3 Turn power off the supporting equipment.



4.1.9    T̲e̲s̲t̲ ̲o̲f̲ ̲S̲i̲t̲e̲ ̲1̲5̲A̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲



4.1.9.1  T̲e̲s̲t̲ ̲S̲e̲t̲-̲U̲p̲

         1   Connect the equipment under test with the supporting
             equipment as shown in figure 4.1.9-1.

         2.1 Check the LTUX-S configuration. The correct configuration
             is described in Appendix A para. 3.1.1.

             The device no. of LTUX-S no. 1 shall be set to
             13…0f…H…0e… and for LTUX-S no. 2 to 14…0f…H…0e….

         2.2 Check that the Stat. Mux. configuration is in accordance
             with the description of Appendix E.

         3   Set the Mode select switch on the BSM-X to "MAN"
             and the Bus select switch to "1".

         4   Turn power on supporting equipment.

         5   Turn power on equipment under test.

         6   Boot test drive system as described in Appendix
             F, part I.



4.1.9.2  T̲e̲s̲t̲ ̲I̲n̲i̲t̲i̲a̲l̲i̲z̲a̲t̲i̲o̲n̲

         Perform initialization as described in Appendix F,
         Part II.






















































         FIGURE 4.1.9-1
         TEST CONFIGURATION SITE 15A


4.1.9.3  T̲e̲s̲t̲ ̲S̲t̲e̲p̲s̲


                                        G̲R̲O̲U̲P̲/̲T̲E̲S̲T̲ ̲N̲O̲.̲:̲ 1/9


         F̲U̲N̲C̲T̲I̲O̲N̲:̲      Interface to TDX-bus, CRT channels,
                        and Crypto/Modem, and Stat. Mux. Multiplexing
                        Traffic flow control

         R̲E̲F̲.̲ ̲S̲D̲S̲ ̲P̲A̲R̲A̲:̲ 3.2.1.1, 3.2.1.2, and 3.2.3

         D̲A̲T̲E̲:̲

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         PROC.   ACTION                 EXPECTED RESULT
         STEP
         NO.
          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         1       Start up the test by   Print out on the Line
                 writing:               Pinter identical with
                 DO DELTA.TEST ̲4  CR    the print out in Appendix
                 on the console         D, apart from the time
                                        indication


            COMMENTS













                                                 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                                TEST WITNESSES


                                               ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                        ̲ ̲ ̲ ̲ ̲ ̲
                                                 TEST QA GQAR




4.1.9.4  T̲e̲s̲t̲ ̲T̲e̲r̲m̲i̲n̲a̲t̲i̲o̲n̲

         1   When the line printer connected to the test drive
             system has stopped, the print out is ready for
             comparison with the listing of Appendix D.

         2   Close-down by

         2.1 Remove the discettes from the floppy-drive.

         2.2 Turn power off the equipment under test.

         2.3 Turn power off the supporting equipment.



4.1.10   T̲e̲s̲t̲ ̲o̲f̲ ̲S̲i̲t̲e̲ ̲1̲5̲B̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲



4.1.10.1 T̲e̲s̲t̲ ̲S̲e̲t̲-̲U̲p̲

         1   Connect the equipment under test with the supporting
             equipment as shown in figure 4.1.10-1.

         2.1 Check the LTUX-S configuration. The correct configuration
             is described in Appendix A para. 3.1.1.

             The device no. of LTUX-S no. 1 shall be set to
             14…0f…H…0e… and for LTUX-S no. 2 to 13…0f…H…0e….

         2.2 Check that the Stat. Mux. configuration is in accordance
             with the description of Appendix E.

         3   Set the Mode select switch on the BSM-X to "MAN"
             and the Bus select switch to "1".

         4   Turn power on supporting equipment.

         5   Turn power on equipment under test.

         6   Boot test drive system as described in Appendix
             F, part I.



4.1.10.2 T̲e̲s̲t̲ ̲I̲n̲i̲t̲i̲a̲l̲i̲z̲a̲t̲i̲o̲n̲

         Perform initialization as described in Appendix F,
         Part II.






















































         FIGURE 4.1.10-1
         TEST CONFIGURATION SITE 15B


4.1.10.3 T̲e̲s̲t̲ ̲S̲t̲e̲p̲s̲


                                        G̲R̲O̲U̲P̲/̲T̲E̲S̲T̲ ̲N̲O̲.̲:̲ 1/10


         F̲U̲N̲C̲T̲I̲O̲N̲:̲      Interface to TDX-bus, CRT channels,
                        and Crypto/Modem, and Stat. Mux. Multiplexing
                        Traffic flow control

         R̲E̲F̲.̲ ̲S̲D̲S̲ ̲P̲A̲R̲A̲:̲ 3.2.1.1, 3.2.1.2, and 3.2.3

         D̲A̲T̲E̲:̲

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         PROC.   ACTION                 EXPECTED RESULT
         STEP
         NO.
          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         1       Start up the test by   Print out on the Line
                 writing:               Pinter identical with
                 DO DELTA.TEST ̲4  CR    the print out in Appendix
                 on the console         D, apart from the time
                                        indication


            COMMENTS













                                                 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                                TEST WITNESSES


                                               ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                        ̲ ̲ ̲ ̲ ̲ ̲
                                                 TEST QA GQAR




4.1.10.4 T̲e̲s̲t̲ ̲T̲e̲r̲m̲i̲n̲a̲t̲i̲o̲n̲

         1   When the line printer connected to the test drive
             system has stopped, the print out is ready for
             comparison with the listing of Appendix D.

         2   Close-down by

         2.1 Remove the discettes from the floppy-drive.

         2.2 Turn power off the equipment under test.

         2.3 Turn power off the supporting equipment.



4.1.11   T̲e̲s̲t̲ ̲o̲f̲ ̲S̲i̲t̲e̲ ̲6̲A̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲



4.1.11.1 T̲e̲s̲t̲ ̲S̲e̲t̲-̲U̲p̲

         1   Connect the equipment under test with the supporting
             equipment as shown in figure 4.1.11-1.

         2.1 Check the LTUX-S configuration. The correct configuration
             is described in Appendix A para. 3.1.1.

             The device no. of LTUX-S no. 1 shall be set to
             13…0f…H…0e… and for LTUX-S no. 2 to 14…0f…H…0e….

         2.2 Check that the Stat. Mux. configuration is in accordance
             with the description of Appendix E.

         3   Set the Mode select switch on the BSM-X to "MAN"
             and the Bus select switch to "1".

         4   Turn power on supporting equipment.

         5   Turn power on equipment under test.

         6   Boot test drive system as described in Appendix
             F, part I.



4.1.11.2 T̲e̲s̲t̲ ̲I̲n̲i̲t̲i̲a̲l̲i̲z̲a̲t̲i̲o̲n̲

         Perform initialization as described in Appendix F,
         Part II.






















































         FIGURE 4.1.11-1
         TEST CONFIGURATION SITE 6A


4.1.11.3 T̲e̲s̲t̲ ̲S̲t̲e̲p̲s̲


                                        G̲R̲O̲U̲P̲/̲T̲E̲S̲T̲ ̲N̲O̲.̲:̲ 1/11


         F̲U̲N̲C̲T̲I̲O̲N̲:̲      Interface to TDX-bus, CRT channels,
                        and Crypto/Modem, and Stat. Mux. Multiplexing
                        Traffic flow control

         R̲E̲F̲.̲ ̲S̲D̲S̲ ̲P̲A̲R̲A̲:̲ 3.2.1.1, 3.2.1.2, and 3.2.3

         D̲A̲T̲E̲:̲

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         PROC.   ACTION                 EXPECTED RESULT
         STEP
         NO.
          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         1       Start up the test by   Print out on the Line
                 writing:               Pinter identical with
                 DO DELTA.TEST ̲4  CR    the print out in Appendix
                 on the console         D, apart from the time
                                        indication


            COMMENTS













                                                 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                                TEST WITNESSES


                                               ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                        ̲ ̲ ̲ ̲ ̲ ̲
                                                 TEST QA GQAR




4.1.11.4 T̲e̲s̲t̲ ̲T̲e̲r̲m̲i̲n̲a̲t̲i̲o̲n̲

         1   When the line printer connected to the test drive
             system has stopped, the print out is ready for
             comparison with the listing of Appendix D.

         2   Close-down by

         2.1 Remove the discettes from the floppy-drive.

         2.2 Turn power off the equipment under test.

         2.3 Turn power off the supporting equipment.



4.1.12   T̲e̲s̲t̲ ̲o̲f̲ ̲S̲i̲t̲e̲ ̲6̲B̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲



4.1.12.1 T̲e̲s̲t̲ ̲S̲e̲t̲-̲U̲p̲

         1   Connect the equipment under test with the supporting
             equipment as shown in figure 4.1.12-1.

         2.1 Check the LTUX-S configuration. The correct configuration
             is described in Appendix A para. 3.1.1.

             The device no. of LTUX-S no. 1 shall be set to
             14…0f…H…0e… and for LTUX-S no. 2 to 13…0f…H…0e….

         2.2 Check that the Stat. Mux. configuration is in accordance
             with the description of Appendix E.

         3   Set the Mode select switch on the BSM-X to "MAN"
             and the Bus select switch to "1".

         4   Turn power on supporting equipment.

         5   Turn power on equipment under test.

         6   Boot test drive system as described in Appendix
             F, part I.



4.1.12.2 T̲e̲s̲t̲ ̲I̲n̲i̲t̲i̲a̲l̲i̲z̲a̲t̲i̲o̲n̲

         Perform initialization as described in Appendix F,
         Part II.






















































         FIGURE 4.1.12-1
         TEST CONFIGURATION SITE 6B


4.1.12.3 T̲e̲s̲t̲ ̲S̲t̲e̲p̲s̲


                                        G̲R̲O̲U̲P̲/̲T̲E̲S̲T̲ ̲N̲O̲.̲:̲ 1/12


         F̲U̲N̲C̲T̲I̲O̲N̲:̲      Interface to TDX-bus, CRT channels,
                        and Crypto/Modem, and Stat. Mux. Multiplexing
                        Traffic flow control

         R̲E̲F̲.̲ ̲S̲D̲S̲ ̲P̲A̲R̲A̲:̲ 3.2.1.1, 3.2.1.2, and 3.2.3

         D̲A̲T̲E̲:̲

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         PROC.   ACTION                 EXPECTED RESULT
         STEP
         NO.
          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         1       Start up the test by   Print out on the Line
                 writing:               Pinter identical with
                 DO DELTA.TEST ̲4  CR    the print out in Appendix
                 on the console         D, apart from the time
                                        indication


            COMMENTS













                                                 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                                TEST WITNESSES


                                               ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                        ̲ ̲ ̲ ̲ ̲ ̲
                                                 TEST QA GQAR




4.1.12.4 T̲e̲s̲t̲ ̲T̲e̲r̲m̲i̲n̲a̲t̲i̲o̲n̲

         1   When the line printer connected to the test drive
             system has stopped, the print out is ready for
             comparison with the listing of Appendix D.

         2   Close-down by

         2.1 Remove the discettes from the floppy-drive.

         2.2 Turn power off the equipment under test.

         2.3 Turn power off the supporting equipment.



4.1.13   T̲e̲s̲t̲ ̲o̲f̲ ̲S̲i̲t̲e̲ ̲7̲A̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲



4.1.13.1 T̲e̲s̲t̲ ̲S̲e̲t̲-̲U̲p̲

         1   Connect the equipment under test with the supporting
             equipment as shown in figure 4.1.13-1.

         2.1 Check the LTUX-S configuration. The correct configuration
             is described in Appendix A para. 3.1.1.

             The device no. of LTUX-S no. 1 shall be set to
             13…0f…H…0e… and for LTUX-S no. 2 to 14…0f…H…0e….

         2.2 Check that the Stat. Mux. configuration is in accordance
             with the description of Appendix E.

         3   Set the Mode select switch on the BSM-X to "MAN"
             and the Bus select switch to "1".

         4   Turn power on supporting equipment.

         5   Turn power on equipment under test.

         6   Boot test drive system as described in Appendix
             F, part I.



4.1.13.2 T̲e̲s̲t̲ ̲I̲n̲i̲t̲i̲a̲l̲i̲z̲a̲t̲i̲o̲n̲

         Perform initialization as described in Appendix F,
         Part II.






















































         FIGURE 4.1.13-1
         TEST CONFIGURATION SITE 7A


4.1.13.3 T̲e̲s̲t̲ ̲S̲t̲e̲p̲s̲


                                        G̲R̲O̲U̲P̲/̲T̲E̲S̲T̲ ̲N̲O̲.̲:̲ 1/13


         F̲U̲N̲C̲T̲I̲O̲N̲:̲      Interface to TDX-bus, CRT channels,
                        and Crypto/Modem, and Stat. Mux. Multiplexing
                        Traffic flow control

         R̲E̲F̲.̲ ̲S̲D̲S̲ ̲P̲A̲R̲A̲:̲ 3.2.1.1, 3.2.1.2, and 3.2.3

         D̲A̲T̲E̲:̲

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         PROC.   ACTION                 EXPECTED RESULT
         STEP
         NO.
          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         1       Start up the test by   Print out on the Line
                 writing:               Pinter identical with
                 DO DELTA.TEST ̲4  CR    the print out in Appendix
                 on the console         D, apart from the time
                                        indication


            COMMENTS













                                                 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                                TEST WITNESSES


                                               ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                        ̲ ̲ ̲ ̲ ̲ ̲
                                                 TEST QA GQAR




4.1.13.4 T̲e̲s̲t̲ ̲T̲e̲r̲m̲i̲n̲a̲t̲i̲o̲n̲

         1   When the line printer connected to the test drive
             system has stopped, the print out is ready for
             comparison with the listing of Appendix D.

         2   Close-down by

         2.1 Remove the discettes from the floppy-drive.

         2.2 Turn power off the equipment under test.

         2.3 Turn power off the supporting equipment.



4.1.14   T̲e̲s̲t̲ ̲o̲f̲ ̲S̲i̲t̲e̲ ̲7̲B̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲



4.1.14.1 T̲e̲s̲t̲ ̲S̲e̲t̲-̲U̲p̲

         1   Connect the equipment under test with the supporting
             equipment as shown in figure 4.1.14-1.

         2.1 Check the LTUX-S configuration. The correct configuration
             is described in Appendix A para. 3.1.1.

             The device no. of LTUX-S no. 1 shall be set to
             14…0f…H…0e… and for LTUX-S no. 2 to 13…0f…H…0e….

         2.2 Check that the Stat. Mux. configuration is in accordance
             with the description of Appendix E.

         3   Set the Mode select switch on the BSM-X to "MAN"
             and the Bus select switch to "1".

         4   Turn power on supporting equipment.

         5   Turn power on equipment under test.

         6   Boot test drive system as described in Appendix
             F, part I.



4.1.14.2 T̲e̲s̲t̲ ̲I̲n̲i̲t̲i̲a̲l̲i̲z̲a̲t̲i̲o̲n̲

         Perform initialization as described in Appendix F,
         Part II.






















































         FIGURE 4.1.14-1
         TEST CONFIGURATION SITE 7B


4.1.14.3 T̲e̲s̲t̲ ̲S̲t̲e̲p̲s̲


                                        G̲R̲O̲U̲P̲/̲T̲E̲S̲T̲ ̲N̲O̲.̲:̲ 1/14


         F̲U̲N̲C̲T̲I̲O̲N̲:̲      Interface to TDX-bus, CRT channels,
                        and Crypto/Modem, and Stat. Mux. Multiplexing
                        Traffic flow control

         R̲E̲F̲.̲ ̲S̲D̲S̲ ̲P̲A̲R̲A̲:̲ 3.2.1.1, 3.2.1.2, and 3.2.3

         D̲A̲T̲E̲:̲

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         PROC.   ACTION                 EXPECTED RESULT
         STEP
         NO.
          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         1       Start up the test by   Print out on the Line
                 writing:               Pinter identical with
                 DO DELTA.TEST ̲4  CR    the print out in Appendix
                 on the console         D, apart from the time
                                        indication


            COMMENTS













                                                 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                                TEST WITNESSES


                                               ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                        ̲ ̲ ̲ ̲ ̲ ̲
                                                 TEST QA GQAR




4.1.14.4 T̲e̲s̲t̲ ̲T̲e̲r̲m̲i̲n̲a̲t̲i̲o̲n̲

         1   When the line printer connected to the test drive
             system has stopped, the print out is ready for
             comparison with the listing of Appendix D.

         2   Close-down by

         2.1 Remove the discettes from the floppy-drive.

         2.2 Turn power off the equipment under test.

         2.3 Turn power off the supporting equipment.



4.1.15   T̲e̲s̲t̲ ̲o̲f̲ ̲S̲i̲t̲e̲ ̲1̲1̲A̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲



4.1.15.1 T̲e̲s̲t̲ ̲S̲e̲t̲-̲U̲p̲

         1   Connect the equipment under test with the supporting
             equipment as shown in figure 4.1.15-1.

         2.1 Check the LTUX-S configuration. The correct configuration
             is described in Appendix A para. 3.1.1.

             The device no. of LTUX-S no. 1 shall be set to
             13…0f…H…0e… and for LTUX-S no. 2 to 14…0f…H…0e….

         2.2 Check that the Stat. Mux. configuration is in accordance
             with the description of Appendix E.

         3   Set the Mode select switch on the BSM-X to "MAN"
             and the Bus select switch to "1".

         4   Turn power on supporting equipment.

         5   Turn power on equipment under test.

         6   Boot test drive system as described in Appendix
             F, part I.



4.1.15.2 T̲e̲s̲t̲ ̲I̲n̲i̲t̲i̲a̲l̲i̲z̲a̲t̲i̲o̲n̲

         Perform initialization as described in Appendix F,
         Part II.






















































         FIGURE 4.1.15-1
         TEST CONFIGURATION SITE 11A


4.1.15.3 T̲e̲s̲t̲ ̲S̲t̲e̲p̲s̲


                                        G̲R̲O̲U̲P̲/̲T̲E̲S̲T̲ ̲N̲O̲.̲:̲ 1/15


         F̲U̲N̲C̲T̲I̲O̲N̲:̲      Interface to TDX-bus, CRT channels,
                        and Crypto/Modem, and Stat. Mux. Multiplexing
                        Traffic flow control

         R̲E̲F̲.̲ ̲S̲D̲S̲ ̲P̲A̲R̲A̲:̲ 3.2.1.1, 3.2.1.2, and 3.2.3

         D̲A̲T̲E̲:̲

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         PROC.   ACTION                 EXPECTED RESULT
         STEP
         NO.
          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         1       Start up the test by   Print out on the Line
                 writing:               Pinter identical with
                 DO DELTA.TEST ̲4  CR    the print out in Appendix
                 on the console         D, apart from the time
                                        indication


            COMMENTS













                                                 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                                TEST WITNESSES


                                               ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                        ̲ ̲ ̲ ̲ ̲ ̲
                                                 TEST QA GQAR




4.1.15.4 T̲e̲s̲t̲ ̲T̲e̲r̲m̲i̲n̲a̲t̲i̲o̲n̲

         1   When the line printer connected to the test drive
             system has stopped, the print out is ready for
             comparison with the listing of Appendix D.

         2   Close-down by

         2.1 Remove the discettes from the floppy-drive.

         2.2 Turn power off the equipment under test.

         2.3 Turn power off the supporting equipment.



4.1.16   T̲e̲s̲t̲ ̲o̲f̲ ̲S̲i̲t̲e̲ ̲1̲1̲B̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲



4.1.16.1 T̲e̲s̲t̲ ̲S̲e̲t̲-̲U̲p̲

         1   Connect the equipment under test with the supporting
             equipment as shown in figure 4.1.16-1.

         2.1 Check the LTUX-S configuration. The correct configuration
             is described in Appendix A para. 3.1.1.

             The device no. of LTUX-S no. 1 shall be set to
             14…0f…H…0e… and for LTUX-S no. 2 to 13…0f…H…0e….

         2.2 Check that the Stat. Mux. configuration is in accordance
             with the description of Appendix E.

         3   Set the Mode select switch on the BSM-X to "MAN"
             and the Bus select switch to "1".

         4   Turn power on supporting equipment.

         5   Turn power on equipment under test.

         6   Boot test drive system as described in Appendix
             F, part I.



4.1.16.2 T̲e̲s̲t̲ ̲I̲n̲i̲t̲i̲a̲l̲i̲z̲a̲t̲i̲o̲n̲

         Perform initialization as described in Appendix F,
         Part II.






















































         FIGURE 4.1.16-1
         TEST CONFIGURATION SITE 11B


4.1.16.3 T̲e̲s̲t̲ ̲S̲t̲e̲p̲s̲


                                        G̲R̲O̲U̲P̲/̲T̲E̲S̲T̲ ̲N̲O̲.̲:̲ 1/16


         F̲U̲N̲C̲T̲I̲O̲N̲:̲      Interface to TDX-bus, CRT channels,
                        and Crypto/Modem, and Stat. Mux. Multiplexing
                        Traffic flow control

         R̲E̲F̲.̲ ̲S̲D̲S̲ ̲P̲A̲R̲A̲:̲ 3.2.1.1, 3.2.1.2, and 3.2.3

         D̲A̲T̲E̲:̲

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         PROC.   ACTION                 EXPECTED RESULT
         STEP
         NO.
          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         1       Start up the test by   Print out on the Line
                 writing:               Pinter identical with
                 DO DELTA.TEST ̲4  CR    the print out in Appendix
                 on the console         D, apart from the time
                                        indication


            COMMENTS













                                                 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                                TEST WITNESSES


                                               ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                        ̲ ̲ ̲ ̲ ̲ ̲
                                                 TEST QA GQAR




4.1.16.4 T̲e̲s̲t̲ ̲T̲e̲r̲m̲i̲n̲a̲t̲i̲o̲n̲

         1   When the line printer connected to the test drive
             system has stopped, the print out is ready for
             comparison with the listing of Appendix D.

         2   Close-down by

         2.1 Remove the discettes from the floppy-drive.

         2.2 Turn power off the equipment under test.

         2.3 Turn power off the supporting equipment.



4.1.17   T̲e̲s̲t̲ ̲o̲f̲ ̲S̲i̲t̲e̲ ̲1̲2̲A̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲



4.1.17.1 T̲e̲s̲t̲ ̲S̲e̲t̲-̲U̲p̲

         1   Connect the equipment under test with the supporting
             equipment as shown in figure 4.1.17-1.

         2.1 Check the LTUX-S configuration. The correct configuration
             is described in Appendix A para. 3.1.1.

             The device no. of LTUX-S no. 1 shall be set to
             13…0f…H…0e… and for LTUX-S no. 2 to 14…0f…H…0e….

         2.2 Check that the Stat. Mux. configuration is in accordance
             with the description of Appendix E.

         3   Set the Mode select switch on the BSM-X to "MAN"
             and the Bus select switch to "1".

         4   Turn power on supporting equipment.

         5   Turn power on equipment under test.

         6   Boot test drive system as described in Appendix
             F, part I.



4.1.17.2 T̲e̲s̲t̲ ̲I̲n̲i̲t̲i̲a̲l̲i̲z̲a̲t̲i̲o̲n̲

         Perform initialization as described in Appendix F,
         Part II.






















































         FIGURE 4.1.17-1
         TEST CONFIGURATION SITE 12A


4.1.17.3 T̲e̲s̲t̲ ̲S̲t̲e̲p̲s̲


                                        G̲R̲O̲U̲P̲/̲T̲E̲S̲T̲ ̲N̲O̲.̲:̲ 1/17


         F̲U̲N̲C̲T̲I̲O̲N̲:̲      Interface to TDX-bus, CRT channels,
                        and Crypto/Modem, and Stat. Mux. Multiplexing
                        Traffic flow control

         R̲E̲F̲.̲ ̲S̲D̲S̲ ̲P̲A̲R̲A̲:̲ 3.2.1.1, 3.2.1.2, and 3.2.3

         D̲A̲T̲E̲:̲

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         PROC.   ACTION                 EXPECTED RESULT
         STEP
         NO.
          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         1       Start up the test by   Print out on the Line
                 writing:               Pinter identical with
                 DO DELTA.TEST ̲4  CR    the print out in Appendix
                 on the console         D, apart from the time
                                        indication


            COMMENTS













                                                 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                                TEST WITNESSES


                                               ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                        ̲ ̲ ̲ ̲ ̲ ̲
                                                 TEST QA GQAR




4.1.17.4 T̲e̲s̲t̲ ̲T̲e̲r̲m̲i̲n̲a̲t̲i̲o̲n̲

         1   When the line printer connected to the test drive
             system has stopped, the print out is ready for
             comparison with the listing of Appendix D.

         2   Close-down by

         2.1 Remove the discettes from the floppy-drive.

         2.2 Turn power off the equipment under test.

         2.3 Turn power off the supporting equipment.



4.1.18   T̲e̲s̲t̲ ̲o̲f̲ ̲S̲i̲t̲e̲ ̲1̲2̲B̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲



4.1.18.1 T̲e̲s̲t̲ ̲S̲e̲t̲-̲U̲p̲

         1   Connect the equipment under test with the supporting
             equipment as shown in figure 4.1.18-1.

         2.1 Check the LTUX-S configuration. The correct configuration
             is described in Appendix A para. 3.1.1.

             The device no. of LTUX-S no. 1 shall be set to
             14…0f…H…0e… and for LTUX-S no. 2 to 13…0f…H…0e….

         2.2 Check that the Stat. Mux. configuration is in accordance
             with the description of Appendix E.

         3   Set the Mode select switch on the BSM-X to "MAN"
             and the Bus select switch to "1".

         4   Turn power on supporting equipment.

         5   Turn power on equipment under test.

         6   Boot test drive system as described in Appendix
             F, part I.



4.1.18.2 T̲e̲s̲t̲ ̲I̲n̲i̲t̲i̲a̲l̲i̲z̲a̲t̲i̲o̲n̲

         Perform initialization as described in Appendix F,
         Part II.






















































         FIGURE 4.1.18-1
         TEST CONFIGURATION SITE 12B


4.1.18.3 T̲e̲s̲t̲ ̲S̲t̲e̲p̲s̲


                                        G̲R̲O̲U̲P̲/̲T̲E̲S̲T̲ ̲N̲O̲.̲:̲ 1/18


         F̲U̲N̲C̲T̲I̲O̲N̲:̲      Interface to TDX-bus, CRT channels,
                        and Crypto/Modem, and Stat. Mux. Multiplexing
                        Traffic flow control

         R̲E̲F̲.̲ ̲S̲D̲S̲ ̲P̲A̲R̲A̲:̲ 3.2.1.1, 3.2.1.2, and 3.2.3

         D̲A̲T̲E̲:̲

          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         PROC.   ACTION                 EXPECTED RESULT
         STEP
         NO.
          ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
         ̲ ̲ ̲ ̲ ̲ ̲

         1       Start up the test by   Print out on the Line
                 writing:               Pinter identical with
                 DO DELTA.TEST ̲4  CR    the print out in Appendix
                 on the console         D, apart from the time
                                        indication


            COMMENTS













                                                 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                                TEST WITNESSES


                                               ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                        ̲ ̲ ̲ ̲ ̲ ̲
                                                 TEST QA GQAR




4.1.18.4 T̲e̲s̲t̲ ̲T̲e̲r̲m̲i̲n̲a̲t̲i̲o̲n̲

         1   When the line printer connected to the test drive
             system has stopped, the print out is ready for
             comparison with the listing of Appendix D.

         2   Close-down by

         2.1 Remove the discettes from the floppy-drive.

         2.2 Turn power off the equipment under test.

         2.3 Turn power off the supporting equipment.