CAMPS SYSTEM DESIGN SPECIFICATION
…02…ISSUE 1…02…CAMPS









                 T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲



   3  ENVIRONMENTS  ................................ 
     3
     3.1  PHYSICAL ENVIRONMENTS .................... 
       3
       3.1.1  Access Dimension ..................... 
         3
       3.1.2  Space ................................ 
         3
       3.1.3  Weight ............................... 
         4
       3.1.4  Ambient Temperature .................. 
         4
       3.1.5  Humidity ............................. 
         5
       3.1.6  Dust, Fumes .......................... 
         5
         3.1.6.1  Air Cleanness .................... 
           5
         3.1.6.2  Fumes ............................ 
           5

       3.1.7  Shock and Vibration .................. 
         6
       3.1.8  Altitude ............................. 
         6

     3.2  INTERFACE DEFINITION ..................... 
       7
       3.2.1  External Netwrok ..................... 
         7
         3.2.1.1  CAMPS - NICS TARE Interface ...... 
           7
           3.2.1.1.1  Physical Interface ........... 
             8
           3.2.1.1.2  Functional Interface ......... 
             8

         3.2.1.2 CAMPS - TRC Interface ............. 
                   9
           3.2.1.2.1  Physical Interface ........... 
             9
           3.2.1.2.2  Functional Interface ......... 
             9

         3.2.1.3  CAMPS - Point-to-Point Connections 
          10
           3.2.1.3.1  Physical Interface ........... 
            10
           3.2.1.3.2  Functional Interface ......... 
            10

       3.2.2  Non-Telegraphic Systems .............. 
        11
         3.2.2.1  CAMPS - SCARS II Interface ....... 
          11
           3.2.2.1.1  Physical Interface ........... 
            11
           3.2.2.1.2  Functional Interface ......... 
            11

         3.2.2.2  CAMPS - CCIS Interface ........... 
          12
           3.2.2.2.1  Physical Interface ........... 
            12
           3.2.2.2.2  Functional Interface ......... 
            12

       3.2.3  Auxiliary Terminal Device ............ 
        13
         3.2.3.1  CAMPS - OCR Interface ............ 
          13
           3.2.3.1.1  Physical Interface ........... 
            13
           3.2.3.1.2  Functional Interface ......... 
            13



         3.2.3.2  CAMPS - Paper Tape Punch Interface 
          14
           3.2.3.2.1  Physical Interface ........... 
            14
           3.2.3.2.2  Functional Interface ......... 
            14

         3.2.3.3  CAMPS - Paper Tape Reader Inter-
                  face ............................. 
                  14
           3.2.3.3.1  Physical Interface ........... 
            14
           3.2.3.3.2  Functional Interface ......... 
            14

         3.2.3.4  CAMPS - Lineprinter Interface .... 
          15
           3.2.3.4.1  Physical Interface ........... 
            15
           3.2.3.4.2  Functional Interface ......... 
            15

       3.2.4  Terminal Device ...................... 
        15
         3.2.4.1  CAMPS - VDU Interface ............ 
          15
           3.2.4.1.1  Physical Interface ........... 
            15
           3.2.4.1.2  Functional Interface ......... 
            16

         3.2.4.2  CAMPS - Medium Speed Printer
                  Interface ........................ 
                  16
           3.2.4.2.1  Physical Interface ........... 
            16
           3.2.4.2.2  Functional Interface ......... 
            16

         3.2.4.3  CAMPS - Low Speed Teleprinter
                  Interface ........................ 
                  17
           3.2.4.3.1  Physical Interface ........... 
            17
           3.2.4.3.2  Functional Interface ......... 
            17

     3.3  PROCEDURAL INTERFACES .................... 
      17
       3.3.1  Display Formats ...................... 
        17
       3.3.2  Print Out Formats .................... 
        18
       3.3.3  Paper Tape Punch Format .............. 
        19
       3.3.4  Paper Tape Reader Format ............. 
        19

     3.4  OPERATOR INTERFACES ...................... 
      19
       3.4.1  User Procedures ...................... 
        19
       3.4.2  MDCO Procedures ...................... 
        20
       3.4.3  Message Service Procedures ........... 
        20
       3.4.4  Supervisor Commands and Procedures ... 
        20
       3.4.5  Engineering Terminal Function ........ 
        21

     3.5  POWER INTERFACES ......................... 
      21
       3.5.1  Power Input Specification ............ 
        21
       3.5.2  Power Sources ........................ 
        22
         3.5.2.1  Power Source Inputs .............. 
          22
         3.5.2.2  Required Power Sources ........... 
          22




                     3̲ ̲ ̲E̲N̲V̲I̲R̲O̲N̲M̲E̲N̲T̲S̲



3.1      P̲H̲Y̲S̲I̲C̲A̲L̲ ̲E̲N̲V̲I̲R̲O̲N̲M̲E̲N̲T̲S̲

         This section addresses the physical environments on
         the location of the CAMPS equipment.

         In designing the equipment no account has been taken
         of catastrophic events such as fire, flood, explosion
         etc.

         The equipment is designed for operation within accomodation
         suitable for the operation of similar equipment produced
         for commercial use.



3.1.1    A̲c̲c̲e̲s̲s̲ ̲D̲i̲m̲e̲n̲s̲i̲o̲n̲

         The equipment is designed to allow for access at sites,
         where the access dimensions are equal to or larger
         than:

         Height: 1.70 m
         Width:  0.65 m
         Length: 3.70 m

         These dimensions give the minimum envelope along the
         access route to any site.



3.1.2    S̲p̲a̲c̲e̲

         The main site equipment is designed for being located
         within room space with the following minimum dimensions:

         Floor area: 7 x 5 m
         Height:         2 m raised floor
                       2.2 without raised floor





3.1.3    W̲e̲i̲g̲h̲t̲

         The heaviest equipment of the installation will be
         one of the 6 EMI-racks with mounted equipment. The
         CAMPS equipment is designed for the following floor
         load limits:

         a)  Structural floor (e.g. concrete floor):

             Max. floor load is less than 425 kg/m…0e…2…0f…

             The calculation of the distributed floor load on
             structural floor includes the floor space required
             for opening of doors and drawers.

         b)  Computer floor:

             Max floor load is less than 825 kg/m…0e…2…0f…

             The calculation of the distributed floor load on
             computer floor uses the floor area covered by the
             un-opened rack.



3.1.4    A̲m̲b̲i̲e̲n̲t̲ ̲T̲e̲m̲p̲e̲r̲a̲t̲u̲r̲e̲

         The CAMPS equipment is designed to operate under the
         following ambient temperature conditions within air
         pressure limits as specified by the altitude limits.

         Range:  10 to 40 deg. C
         Change: Max. 10 deg. C per hour

         The temperature is measured at the air input location
         of the item of equipment.

         The temperature limits are specified on the condition
         that filters, fans and other parts affecting cooling
         are maintained as described in the rules of preventive
         maintenance of the item of equipment.

         After loss of heating or air-conditioning in the CAMPS
         room, the operators shall take action to prevent equipment
         damages due to excessive temperatures within 15 minutes,
         corresponding to a temperature change of 2.5 deg. C.

         A temperature warning is given by the equipment at
         35 deg. C to alarm operators.


3.1.5    H̲u̲m̲i̲d̲i̲t̲y̲

         The equipment is designed to operate within the following
         humidity ranges:

         Range:  40 to 90% relative humidity, non-condensing

         Change: Max 6% relative humidity per hour. 



3.1.6    D̲u̲s̲t̲,̲ ̲F̲u̲m̲e̲s̲

         The equipment is designed for operation within accomodation
         suitable for operation of similar equipment produced
         for commercial use. This means, that dust and noxious
         fumes are at a level not to cause significant influence.



3.1.6.1  A̲i̲r̲ ̲c̲l̲e̲a̲n̲n̲e̲s̲s̲

         The air cleanness is specified as follows:

         Particle size              Max. allowable number
         (̲m̲i̲c̲r̲o̲n̲s̲)̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲(̲p̲a̲r̲t̲i̲c̲l̲e̲s̲/̲c̲u̲b̲i̲c̲m̲e̲t̲e̲r̲)̲ ̲

         greater than 5             4…0f…*…0e…10…0e…5…0f…
         greater than 1.5           4…0f…*…0e…10…0e…6…0f…
         greater than 1             4…0f…*…0e…10…0e…7…0f…

         Regulations for preventive maintenance will give the
         rules for cleaning equipment (filters etc.)



3.1.6.2  F̲u̲m̲e̲s̲

         Sulphur dioxide             max. 14 ppm

         The equipment is designed for an agressive environment
         not to exceed the level determined by the specified
         amount of sulphur dioxide.





3.1.7    S̲h̲o̲c̲k̲ ̲a̲n̲d̲ ̲V̲i̲b̲r̲a̲t̲i̲o̲n̲

         The equipment is designed for operation within accomodation
         suitable for the operation of similar equipment produced
         for commercial use.

         The items determining the shock and vibration performance
         of the site equipment are OEM-items procured in compliance
         with the statement above.



3.1.7.1  E̲q̲u̲i̲p̲m̲e̲n̲t̲ ̲P̲l̲a̲c̲e̲d̲ ̲i̲n̲ ̲R̲a̲c̲k̲s̲



3.1.7.1.1    C̲R̲ ̲P̲r̲o̲d̲u̲c̲e̲d̲ ̲I̲t̲e̲m̲s̲

         a)  V̲i̲b̲r̲a̲t̲i̲o̲n̲

             Operating and Storage:

             5 Hz to 50 Hz constant displacement of 0.02 mm.
             50 Hz smooth crossover, 50 Hz - 350 Hz constant
             acceleration 0.2g.

             Transportation:

             5 Hz to 350 Hz constant acceleration 1.5 g.

         b)  S̲h̲o̲c̲k̲

             Operating and Storage:

             1 g, half sine wave, 10 ms duration. Not to be
             repeated more often than one per 10 seconds.

             Transportation:

             25 g, half sine wave, 10 ms duration.





3.1.7.1.2    D̲i̲s̲k̲ ̲D̲r̲i̲v̲e̲s̲

         V̲i̲b̲r̲a̲t̲i̲o̲n̲ ̲a̲n̲d̲ ̲S̲h̲o̲c̲k̲

         a)  Operating

             Equipment, as normally installed and positioned,
             meets the fully specified performance while subject
             to the following conditions injected from the floor
             in a vertical direction:

             1)  Continuous vibration as indicated in Figure
                 3.1.7-1 operating curve A.

             2)  Intermittent shocks (2 per second or fewer)
                 of up to 2 g not exceeding 10 ms in duration.

         b)  T̲r̲a̲n̲s̲i̲t̲ ̲(̲A̲s̲ ̲P̲a̲c̲k̲e̲d̲ ̲f̲o̲r̲ ̲S̲h̲i̲p̲m̲e̲n̲t̲)̲

             Equipment in an upright position will withstand
             the conditions of vibration and shock, base input
             only, as follows:

             1)  Vibration, as shown in Figure 3.1.7-1, non-operating
                 curve C.

             2)  Shocks of up to 20 g not exceeding 10 ms in
                 duration. The time between consecutive shocks
                 cannot be less than 5 seconds.



















































             FIGURE 3.1.7-1…01…VIBRATION LEVELS


3.1.7.1.3    F̲l̲o̲p̲p̲y̲ ̲D̲i̲s̲k̲ ̲D̲r̲i̲v̲e̲s̲

         a)  S̲h̲o̲c̲k̲

             The level specified for shock applies to three
             mutually perpendicular directions (Principle cabinet
             axis).

             -   Operating

                 Equipment shall operate during and after subjecting
                 to a maximum shock level of 1 g. Shock duration
                 shall be 10 to 20 milliseconds.

             -   Non-Operating

                 Equipment shall operate after a maximum shock
                 level of 15 gs. Shock duration shall be 10
                 to 20 milliseconds.

         b)  V̲i̲b̲r̲a̲t̲i̲o̲n̲

             The level specified for vibration applies to three
             mutually perpendicular directions (Principle cabinet
             axis).

             Equipment shall be operable during and after the
             maximum vibration levels of the following table.



                             FREQUENCY   DOUBLE   AMPLITUDE
                                Hz         IN        Gs
                              ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                             ̲ ̲

             Operating        5-25       .0014    --
                             25-55       .0007    --
                             55-300      --       0.3

             Non-Operating    5-25       .008     --
                             25-55       .0004    --
                             55-300      --       2.0





3.1.7.2  T̲e̲r̲m̲i̲n̲a̲l̲s̲ ̲a̲n̲d̲ ̲M̲o̲d̲e̲m̲

         The following terminal equipment is addressed:

         VDU     Visual Display Unit
         MSP     Medium Speed Printer
         PTP/PTR Paper Tape Reader/Paper Tape Puncher
         LP      Line Printer

         Modem for NICS TARE Connection

         Typical Data, Vibration

         Amplitude:       .020 in. (da) plus/minus .0004 in
                          (da)
         Frequency range: 4 Hz - 33 Hz - 4 Hz
         Sweep Time:      10 min. plus/minus 2 min. (up down)
         Total Test time: 2 hours


3.1.8    A̲l̲t̲i̲t̲u̲d̲e̲

         The operating specifications above are related to equipment
         operating within the altitude range:

         Sea level to 2000 meter.


3.2      I̲N̲T̲E̲R̲F̲A̲C̲E̲ ̲D̲E̲F̲I̲N̲I̲T̲I̲O̲N̲

         This section defines the CAMPS interfaces to the following
         systems/equipments:

         a)  External network

             -   NICS-TARE
             -   TRC
             -   Point-to-Point Connections

         b)  Non-telegraphic system

             -   SCARS II
             -   CCIS

         c)  Auxiliary terminal device

             -   OCR
             -   PTP
             -   PTR
             -   Line printer

         d)  Terminal device

             -   VDU
             -   Medium speed teleprinter
             -   Low speed teleprinter

         Both the functional and physical interfaces for each
         of the listed systems/equipments are described in the
         following sections.



3.2.1    E̲x̲t̲e̲r̲n̲a̲l̲ ̲N̲e̲t̲w̲o̲r̲k̲



3.2.1.1  C̲A̲M̲P̲S̲ ̲-̲ ̲N̲I̲C̲S̲ ̲T̲A̲R̲E̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         NICS TARE is a network to which CAMPS is connected.

         For further details than described in this section
         see document CPS/ICD/004 which describes the following
         interface protocols:



         -   Electrical Interface
         -   Link Control
         -   Message Traffic



3.2.1.1.1    P̲h̲y̲s̲i̲c̲a̲l̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         CAMPS is connected to NICS TARE either via a direct
         link (colocated NICS TARE) or via a crypto/modem link
         (remote NICS TARE).

         The electrical interface is in accordance with the
         CCITT recommendation V24/V28 inclusive the V28 modifications
         specified in CPS/ICD/004 section 3.2.

         The transmission is synchronous full-duplex with the
         baud rates 600, 1200, or 2400 bps.



3.2.1.1.2    F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         Link protocol is described in CPS/ICD/004.

         The character code used, is the NATO 7-bit code, which
         is based on the ITA no. 5.

         All messages transmitted and received via NICS TARE
         are in ACP127 format.

         Messages related to maintain and control the communication
         between stations are in general treated by the supervisor,
         but those listed below are automatically generated/analyzed
         by CAMPS:

         -   Consecutive Identical Characters
         -   Receipt of Flash Messages
         -   Continuity Check
         -   Channel Number Reset
         -   Channel Opening/Closing

         The listed messages will be of type Abbreviated Service
         Messages. For further details see CPS/ICD/004 section
         5.





3.2.1.2  C̲A̲M̲P̲S̲ ̲-̲ ̲T̲R̲C̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         Tape Relay Center (TRC) is an alternative destribution
         network to NICS TARE. The operation of these networks
         is manual.

         For further details than described in this section
         see document CPS/ICD/007 which describes the electrical
         protocol and message traffic protocol.



3.2.1.2.1    P̲h̲y̲s̲i̲c̲a̲l̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         CAMPS is connected to TRC by a direct link or via a
         crypto/low speed link. The interface protocol is the
         same whether a direct link or a crypto/low speed link
         is used.

         The electrical interface is in accordance with the
         CCITT recommendation V24/V28 inclusive the V28 modifications
         specified in CPS/ICD/007 section 3.2.

         The transmission is asynchronous full duplex or simplex
         with baud rates of 50 or 75 bps.

         A seven bit character code with one start bit, five
         data bits and one stop bit or a ten bit character code
         with one start bit, seven data bits, one parity bit
         and one stop bit.



3.2.1.2.2    F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         The alphabet used is either the ITA no. 2 or the NATO
         7-bit code which is based on the ITA no. 5.

         CAMPS can convert ITA no. 5 to ITA no. 2 and vice versa.
          The rules for this conversion are described in section
         4.3 of CPS/ICD/007.

         All messages transmitted and received via TRC are in
         ACP127 format.

         Messages related to maintenance and control of the
         communication between stations are in general treated
         by the supervisor, but those listed below are automatically
         generated/analyzed by CAMPS:



         -   Consecutive Identical Characters
         -   Receipt of Flash Messages
         -   Channel Number Reset
         -   Channel Opening/Closing
         -   Continuity Check

         The listed messages will be of Abbreviated Service
         Messages type.  For further details see CPS/ICD/007
         section 5.



3.2.1.3  C̲A̲M̲P̲S̲ ̲-̲ ̲P̲o̲i̲n̲t̲-̲t̲o̲-̲P̲o̲i̲n̲t̲ ̲C̲o̲n̲n̲e̲c̲t̲i̲o̲n̲s̲

         Point-to-Point Connections (P-to-P) are alternative
         communication lines on which messages can be interchanged
         between stations.



3.2.1.3.1    P̲h̲y̲s̲i̲c̲a̲l̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         The physical interface is the same as for the TRC interface
         (see 3.2.1.2.1) except for the following:

         -   the transmission speed is 50, 75, 110, 300, or
             600 bps.

         Note that if speeds of 300 or 600 bps are used this
         is on internal systems only and will not interface
         with a crypto equipment.



3.2.1.3.2    F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         The functional interface is the same as for the TRC
         interface (see 3.2.1.2.2).





3.2.2    N̲o̲n̲-̲T̲e̲l̲e̲g̲r̲a̲p̲h̲i̲c̲ ̲S̲y̲s̲t̲e̲m̲s̲



3.2.2.1  C̲A̲M̲P̲S̲ ̲-̲ ̲S̲C̲A̲R̲S̲ ̲I̲I̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         SCARS II is a system on which CAMPS has the capability
         to receive and transmit messages.  For further details
         than described in this section, see document CPS/ICD/005
         which describes the following interface protocols:

         -   Electrical interface
         -   Link control
         -   Logical channel concept
         -   Message traffic



3.2.2.1.1    P̲h̲y̲s̲i̲c̲a̲l̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         CAMPS is connected to SCARS II via a direct link (colocated).

         The electrical interface is in accordance with the
         CCITT's recommendation V24/V28.  V28 is a modified
         version as specified in CPS/ICD/005.

         The transmission is synchronous full-duplex with baud
         rate 9600 bps.


3.2.2.1.2    F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         The link protocol is the x.25 level 2 with modificatons
         as specified in CPS/ICD/005.

         The logical channel concept (level 3 protocol) provides
         a capability to indicate the type of data being transferred
         between CAMPS and SCARS II.

         The character code used is the NATO 7-bit code, which
         is based on the ITA no. 5.

         Three types of data are transmitted and/or received:

         -   messages
         -   terminal to terminal comments
         -   VDU pages



         The supervisor is informed if any mal-function of the
         communication line occurs. It is the responsibility
         of the supervisor to take action to repair the communication.

         The system will automatically maintain and control
         the communication between stations by means of:

         -   check of link security levels at initialization

         -   resetting of transmission sequence numbers



3.2.2.2  C̲A̲M̲P̲S̲ ̲-̲ ̲C̲C̲I̲S̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         CCIS is a data base system to which CAMPS have the
         capability to receive and transmit messages. For further
         details than described in this section see document
         CPS/ICD/006 which describes the following interface
         protocols:

         -   Electrical interface
         -   Link control
         -   Logical channel concept
         -   Message traffic



3.2.2.2.1    P̲h̲y̲s̲i̲c̲a̲l̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         The physical interface is the same as for CAMPS - SCARS
         II interface as described in section 3.2.2.1.1.



3.2.2.2.2    F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         The functional interface is the same as for CAMPS -
         SCARS II interface as described in section 3.2.2.1.2.





3.2.3    A̲u̲x̲i̲l̲i̲a̲r̲y̲ ̲T̲e̲r̲m̲i̲n̲a̲l̲ ̲D̲e̲v̲i̲c̲e̲



3.2.3.1  C̲A̲M̲P̲S̲ ̲-̲ ̲O̲C̲R̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         Optical Character Reader is an input media through
         which formatted messages printed on paper can be entered
         into the CAMPS system.  For further details than described
         in this sections see document CPS/ICD/008, which describes
         the following interface protocols:

         -   Electrical interface
         -   Link control
         -   Message format



3.2.3.1.1    P̲h̲y̲s̲i̲c̲a̲l̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         OCR is directly connected to CAMPS with interchange
         circuits conforming to CCITT's recommendation V24/V28
         including the V28 modifications specified in CPS/ICD/008
         section 3.2.

         The transmission is asynchronous with baud rates 2400,
         4800 or 9600 bps.

         A ten bit character code with one start bit, seven
         data bits, one parity bit and one stop bit is used.



3.2.3.1.2    F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         A link protocol is employed which give CAMPS the facility
         to control the open/close of the OCR and to control
         the transmission of data in blocks of 512 bytes.

         The alphabet used is the ITA no. 5.

         Only complete messages are entered into the OCR and
         delivered to CAMPS for further processing. The format
         of the message is similar to Format A in CPS/230/ICD/0001.
         The format description is given in CPS/ICD/008 section
         5.





3.2.3.2  C̲A̲M̲P̲S̲ ̲-̲ ̲P̲a̲p̲e̲r̲ ̲T̲a̲p̲e̲ ̲P̲u̲n̲c̲h̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         Paper Tape Punch (PTP) is an output media on which
         messages can be punched out.



3.2.3.2.1    P̲h̲y̲s̲i̲c̲a̲l̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         The electrical interface is in accordance with the
         CCITT's recommendation V24/V28 (low level).

         The transmission is asynchronous.

         A seven bit character code (start-, stop bit) (ITA
         no. 2) or a ten bit character code (start-, parity-,
         stop bit) (ITA no. 5) can be used.



3.2.3.2.2    F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         The alphabet used is either the ITA no. 2 or ITA no.
         5.

         The format of the punched message is in ACP127 format
         without format line 1.



3.2.3.3  C̲A̲M̲P̲S̲ ̲-̲ ̲P̲a̲p̲e̲r̲ ̲T̲a̲p̲e̲ ̲R̲e̲a̲d̲e̲r̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         Paper Tape Reader (PTR) is an input media on which
         messages can be entered into CAMPS.



3.2.3.3.1    P̲h̲y̲s̲i̲c̲a̲l̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         The interface is the same as for PTP.



3.2.3.3.2    F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         The interface is the same as for PTP.

         The entered data shall be complete messages in ACP127
         format without format line 1.


3.2.3.4  C̲A̲M̲P̲S̲ ̲-̲ ̲L̲i̲n̲e̲p̲r̲i̲n̲t̲e̲r̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         The lineprinter is used as an output media at the operator
         position.



3.2.3.4.1    P̲h̲y̲s̲i̲c̲a̲l̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         The lineprinter is connected to CAMPS via a low level
         CCITT recommended V24/V28 interface.

         The transmission is asynchronous with a baud rate of
         4800 or 9600 bps.

         A ten bit character code (start-, parity-, stop bit)
         is used.



3.2.3.4.2    F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         The alphabet used is the ITA no. 5.

         The lineprinter provides the facility for the operator
         to get system status and error reports printed out.



3.2.4    T̲e̲r̲m̲i̲n̲a̲l̲ ̲D̲e̲v̲i̲c̲e̲



3.2.4.1  C̲A̲M̲P̲S̲ ̲-̲ ̲V̲D̲U̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         Visual Display Units (VDU) are used as the main communication
         media between CAMPS and a user.



3.2.4.1.1    P̲h̲y̲s̲i̲c̲a̲l̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         The VDUs are connected to CAMPS via a CCITT recommendation
         V24 interface and an opto transmission link.

         The transmission is asynchronous with a baud rate of
         1200 or 2400 bps.

         A ten bit character code with one start bit, seven
         bits, one parity bit, and one stop bit is used.


3.2.4.1.2    F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         The alphabet used is the ITA no. 5.

         The VDU provides the user (and supervisor) the facility
         to communicate with the CAMPS system in an interactive
         manner.

         The format of the displayed items are described in
         CPS/230/ICD/0001 and CPS/230/ICD/0002.



3.2.4.2  C̲A̲M̲P̲S̲ ̲-̲ ̲M̲e̲d̲i̲u̲m̲ ̲S̲p̲e̲e̲d̲ ̲P̲r̲i̲n̲t̲e̲r̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         The Medium Speed printer is an output media on which
         messages can be printed.



3.2.4.2.1    P̲h̲y̲s̲i̲c̲a̲l̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         The Medium Speed Printers are connected to CAMPS via
         a CCITT recommendation V24 interface and an opto transmission
         link.

         The transmission is asynchronous with a baud rate of
         1200 bps.

         A ten bit character code with one start bit, seven
         data bits, one parity bit and one stop bit are used.



3.2.4.2.2    F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         The alphabet used is the ITA no. 5.

         The printed items will be messages, comments and status
         information.

         The format of the printouts will be similar to the
         display formats, which are described in CPS/230/ICD/0001
         and CPS/230/ICD/0002.





3.2.4.3  C̲A̲M̲P̲S̲ ̲-̲ ̲L̲o̲w̲ ̲S̲p̲e̲e̲d̲ ̲T̲e̲l̲e̲p̲r̲i̲n̲t̲e̲r̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         The low speed teleprinter is an input/output media
         through which messages can be entered into CAMPS or
         delivered from CAMPS.



3.2.4.3.1    P̲h̲y̲s̲i̲c̲a̲l̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         The low speed teleprinters are connected to CAMPS via
         a low level CCITT recommended V24/V28 interface.

         The transmission is asynchronous with a baud rate of
         50, 75 bps, 300 bps, or 600 pbs.

         A seven bit character code with one start bit, five
         data bits and one stop bit, or a ten bit character
         code with one start bit, seven data bits, one parity
         bit and one stop bit.



3.2.4.3.2    F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲I̲n̲t̲e̲r̲f̲a̲c̲e̲

         The alphabet used is either ITA no. 2 or ITA no. 5.

         Three modes of operation are possible using a low speed
         teleprinter. These are:

         a)  Input of complete messages in ACP127 format without
             format line 1. The message is in the form of a
             paper tape.

         b)  Output of messages in ACP127 without format line
             1. The message is in the form of a paper tape.

         c)  Output of items printed on paper in a display format
             as described in CPS/230/ICD/0001. The use is similar
             to that of a medium speed printer.

3.3      P̲R̲O̲C̲E̲D̲U̲R̲A̲L̲ ̲I̲N̲T̲E̲R̲F̲A̲C̲E̲S̲



3.3.1    D̲i̲s̲p̲l̲a̲y̲ ̲F̲o̲r̲m̲a̲t̲s̲

         The display formats related to the user and supervisor
         procedures are described in the ICD's CPS/230/ICD/0001
         and CPS/230/ICD/0002.


3.3.2    P̲r̲i̲n̲t̲ ̲O̲u̲t̲ ̲F̲o̲r̲m̲a̲t̲s̲

         Each print out copy contains a document control number.

         The layout of the content of the formats are similar
         to the layout of the display formats.

         A printout copy has the following general layout:

         -   Each page shall contain N lines, where N can be
             specified separately for each device type by the
             supervisor.

         -   Line 1 shall contain only a "-" at the left hand
             margin.

         -   Line 2 shall be blank.

         -   Line 3 shall be the next line of the relevant format.

         -   Line (N-3) shall be the last line on the page from
             the relevant format.

         -   Line N shall contain only a "-" at the left hand
             margin.


             P̲h̲y̲s̲i̲c̲a̲l̲ ̲L̲i̲n̲e̲

                 1      -
                 2
                 3      (first format line of this page)
                 4      (second format line of this page)
                 5      (third format line of this page)
                 6      (fourth format line of this page)
                 7      (fifth format line of this page)
                 
                 N-4    (second to last format line of this page
                 N-3    (last format line of this page)
                 N-2    
                 N-1
                 N      -





3.3.3    P̲a̲p̲e̲r̲ ̲T̲a̲p̲e̲ ̲P̲u̲n̲c̲h̲ ̲F̲o̲r̲m̲a̲t̲

         The format of messages punched on a PTP is ACP127 format
         in ITA 2 coding, with the exception that format line
         one is removed. The punched tape shall be preceded
         by 20 cms blank tape and succeeded by 20 cms blank
         tape. A document control number will be punched in
         front of the message punched out.



3.3.4    P̲a̲p̲e̲r̲ ̲T̲a̲p̲e̲ ̲R̲e̲a̲d̲e̲r̲ ̲F̲o̲r̲m̲a̲t̲

         The format of messages entered via a PTR is ACP127
         format in ITA 2 coding with the exception that format
         line one is removed.



3.4      O̲P̲E̲R̲A̲T̲O̲R̲ ̲I̲N̲T̲E̲R̲F̲A̲C̲E̲S̲

         Operator interfaces are described in details in Interface
         Control Documents (ICD).



3.4.1    U̲s̲e̲r̲ ̲P̲r̲o̲c̲e̲d̲u̲r̲e̲s̲

         The user procedures and associated formats are described
         in CPS/230/ICD/0001.  The following procedures are
         available to the user:

         -   Sign-on
         -   New message preparation
         -   Append message
         -   New comment preparation
         -   Continue message preparation
         -   Continue comment preparation
         -   Prepare predefined message
         -   Message/comment deletion
         -   Message/comment retrieval
         -   Message status
         -   Delivery status
         -   Sign-off
         -   Display of messages
         -   Security interrogarion
         -   Security warning



         The following procedures are only available to the
         releaser:

         -   Message release
         -   Message release status



3.4.2    M̲D̲C̲O̲ ̲P̲r̲o̲c̲e̲d̲u̲r̲e̲s̲

         The MDCO procedures and associated formats are described
         in CPS/230/ICD/0002.  The following procedures are
         available to the MDCO:

         -   Correction of Message for distribution
         -   Retrieval of message for distribution



3.4.3    M̲e̲s̲s̲a̲g̲e̲ ̲S̲e̲r̲v̲i̲c̲e̲ ̲P̲r̲o̲c̲e̲d̲u̲r̲e̲s̲

         The Message Service procedures and associated formats
         are described in CPS/230/ICD/0002.  The following procedures
         are available to the Message Service:

         -   Correction to incoming garbled messages

         -   Service to outgoing messages



3.4.4    S̲u̲p̲e̲r̲v̲i̲s̲o̲r̲ ̲C̲o̲m̲m̲a̲n̲d̲s̲ ̲a̲n̲d̲ ̲P̲r̲o̲c̲e̲d̲u̲r̲e̲s̲

         The supervisor commands, procedures and formats are
         described in CPS/230/ICD/0002.  The following commands
         and procedures are available to the Supervisor:

         -   Sign-on
         -   Supervisor command control
         -   Device control
         -   User profile update
         -   Security control
         -   Queue control at restart
         -   Table update
         -   Abbreviated service message
         -   Retrieval
         -   ACP127 parameters
         -   MDCO control
         -   Sign-off
         -   Supervisor engineering functions


3.4.5    E̲n̲g̲i̲n̲e̲e̲r̲i̲n̲g̲ ̲T̲e̲r̲m̲i̲n̲a̲l̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲

         The engineering commands and functions are described
         in section 6 of CPS/230/ICD/0002.



3.5      P̲O̲W̲E̲R̲ ̲I̲N̲T̲E̲R̲F̲A̲C̲E̲S̲

         This section specifies the design parameters for the
         power interfaces of items of CAMPS equipment.



3.5.1    P̲o̲w̲e̲r̲ ̲I̲n̲p̲u̲t̲ ̲S̲p̲e̲c̲i̲f̲i̲c̲a̲t̲i̲o̲n̲

         All items of CAMPS equipment are designed to meet the
         following input specifications:

         a)  Phases:          Single- or 3-phase, and ground.

         b)  Voltage:         Nominal Value 380/220 V AC
                              Tolerances: +10%/-15%
                              Except UKAIR where nominal value
                              is 405/240 V AC.

         c)  Frequency:       Nominal value: 50 HZ
                              Tolerances: +10/-10%

         d)  Harmonic
             distortion:      Max. 5%

         e)  Transients:      Non-repetitive impulsive interference
                              with a magnitude not to exceed
                              500 volts, pulse rise and fall
                              times not faster than 10 microseconds
                              and a total duration of maximum
                              1 millisecond. The available impulse
                              energy at the equipment power
                              inlet shall not exceed 5J.

         f)  Exemptions:      Each site equipment will contain
                              three disk drives. These will
                              not operate within the tolerances
                              of section b) and c) above, but:




                         1) Voltage:   Nominal value 380/220V
                         AC
                                       Tolerances: +6%/-10%

                         2) Frequency: Nominal value: 50 Hz
                                       Tolerance: +0,5 Hz/-1.0
                         Hz



3.5.2    P̲o̲w̲e̲r̲ ̲S̲o̲u̲r̲c̲e̲s̲



3.5.2.1  P̲o̲w̲e̲r̲ ̲S̲o̲u̲r̲c̲e̲ ̲I̲n̲p̲u̲t̲s̲

         The number of power source inputs per item of equipment
         is designed to meet the availability requirements of
         CPS/210/SYS/0001.

         a)  All items of terminal equipment have a single power
             source input.

         b)  The 6 racks of the main site rack assemblies have
             2 power source inputs per rack. The racks are constructed
             as 2 3-bay rack-assemblies.



3.5.2.2  R̲e̲q̲u̲i̲r̲e̲d̲ ̲P̲o̲w̲e̲r̲ ̲S̲o̲u̲r̲c̲e̲s̲

         The power sources are fed into the Computer Rack-Assembly
         and the Line Termination Rack-Assembly through RF line
         filters. The filtered power sources are distributed
         to the power source inputs of the racks in each Assembly.