3864A/ktd …02…CPS/TCM/005
…02…KJA/830912…02……02…
CAMPS SITE LEVEL MAINTENANCE MANUAL
…02…Issue 1…02… CAMPS
PERIPHERAL TEST PROCEDURES STEP 6000 - 7000 (cont'd)
STEP PROCEDURE OBSERVATION/ACTION
̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
3864A/ktd …02…CPS/TCM/005
…02…KJA/830912…02……02…
CAMPS SITE LEVEL MAINTENANCE MANUAL
…02…Issue 1…02… CAMPS
4.3.3.6 P̲E̲R̲I̲P̲H̲E̲R̲A̲L̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲ ̲T̲e̲s̲t̲ ̲P̲r̲o̲c̲e̲d̲u̲r̲e̲s̲
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6000 PERIPHERAL TEST ENTRY
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6005 Analyze the situa- o If
the
peripheral
is
connected
via
an
tion OPTO module then
GO TO step 6010
o If the peripheral is connected
via a L/L Adaptor then
GO TO step 6050
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6010 Check that the MSP/ o The
output
of
the
OPTO
module/wire
VDU keylock is ON should range within
Check the intensity - 8dbm to - 34,6 dbm.
of the OUT port of
the VDU/MSP OPTO
module The OPTO LEDs should be as
follows:
Check the intensity
of the OPTO wire con- L̲E̲D̲ ̲ ̲ ̲ ̲ ̲V̲D̲U̲ ̲ ̲ ̲ ̲ ̲M̲S̲P̲
nected to the IN port
of the VDU/MSP OPTO POWER ON ON
module. RCVL OFF OFF
RTS OFF ON
Check that the two CTS OFF ON
OPTO wires are pro- SYNC OFF OFF
perly connected to ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
̲
the VDU/MSP.
Check the LEDs in the
VDU/MSP OPTO module If correct, GO TO step 6035
o If the POWER LED is OFF then
- Check the OPTO module
fuse (if VDU OPTO)
- Check that power is applied
to the VDU/MSP unit.
- Replace the OPTO module
(if necessary)
Repeat step 6010
o If the output intensity of
the OPTO module is outside
the range then it indicates
an error in the VDU/MSP OPTO
module.
Replace OPTO module
Repeat step 6010
o If the output intensity of
the OPTO wire is outside the
range
GO TO step 6025
o If the LEDs in the VDU/MSP
OPTO module are as follows:
RCVL ON or/and
SYNC ON
then it indicates an error
in the input to the VDU/MSP
GO TO step 6015
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6015 Connect a Loopback o The
LEDs
should
be
as
follows:
cable to the OUT
and IN port of the RCVL OFF
VDU/MSP OPTO module SYNC OFF
If correct, GO TO step 6025
o If the LEDs are not as shown
above
Replace the VDU/MSP OPTO
module
Repeat step 6015
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6020 Connect the OPTO o The
intensity
should
be
within
the
cables properly range
to the
VDU/MSP OPTO module - 8dbm to - 34,6 dbm
If correct GO TO step 6025
Dismount the two
OPTO wires from
the OPTO module in
the Adaptor/TDX crate
Check the intensity
of the OPTO cable con-
nected to the IN Port
of the Adaptor/TDX crate.
o If the intensity is out of
range then it indicates an
error in the OPTO cable connected
from the OUT port of the VDU/MSP
OPTO module and to the IN port
of Adaptor/TDX crate.
It is necessary to replace
it or cut a piece of the OPTO
wire and then make a new connector
when the error is cleared.
Verify the Peripheral Subsystem
GO TO step 6900
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6025 Check the intensity o The
intensity
should
range
within:
of the OUT port
of the Adaptor/TDX - 8dbm to - 34,6 dbm
OPTO module
If correct, GO TO step 6030
o If the intensity is out of
range, then it indicates an
error in the Adaptor/TDX OPTO
module.
Replace the OPTO module
(Refer to sec. 4.4)
Repeat step 6030.
When the error is cleared
Verify the Peripheral
Subsystem.
GO TO step 6900
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6030 Connect the OPTO o -The
intensity
should
be
within
the
Loopback tube to range:
the two dismounted
OPTO wires in the - 8 dbm to - 34,6 dbm
Adaptor/TDX crate. The LEDs should be as follows
Dismount the OPTO RCVL OFF
wire connected to SYNC OFF
the IN port of the
VDU/MSP OPTO module If correct, then it indicates
an error in the Adaptor/TDX
Check the intensi- OPTO module
ty of the dis-
mounted OPTO Replace the OPTO module
wire. (refer to sec. 4.4)
Verify the Peripheral
Subsystem
Connect the OPTO
wire to the IN port GO TO step 6900
again.
Check the LEDs of o If the intensity is outside
the range
the VDU/MSP OPTO then it indicates an error
in the OPTO
module. cable between the OUT port
of the Adaptor/TDX OPTO module
and the IN port of the VDU/MSP
OPTO module.
It is necessary to replace
it or cut a piece of the OPTO
wire and then make a new connector.
When the error is cleared
Verify the Peripheral Subsystem
GO TO step 6900
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6035 Open the doors to the o The
LEDs
in
the
OPTO
module
should
be:
actual TDX/Adaptor
Crate. Check the POWER ON
LEDs in the RCVL OFF
TDX/Adaptor OPTO SYNC OFF
module connected
to the VDU/MSP.
If correct then it indicates
that there is no LED error
in the OPTO transmission between
the VDU/MSP and the Adaptor/TDX
crate.
GO TO step 6055.
o If the POWER LED is "OFF" then
Replace OPTO module
(refer to section 4.4)
Repeat step 6035
If the POWER LED is still "OFF"
then it indicates an error
in either the Adaptor/TDX crate
or in the Adaptor power supply.
If TDX crate: GO TO step 4800
If Adaptor crate: GO TO step
5800.
o If the LEDs in the TDX/Adaptor
OPTO module are as follows:
RCVL ON and/or
SYNC ON
then it indicates an error
in the connection between the
TDX/Adaptor OPTO MODULE and
the VDU/MSP.
GO TO step 6040.
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6040 Check the intensity o The
output
should
be
within
the
range
from the OUT-port
of the Adaptor/TDX
OPTO module -8 dbm to -34,6 dbm
Check the intensity The LEDs in the Adaptor/TDX
OPTO
of the OPTO wire module should be
connected to the
IN port.
Connect the OPTO RCVL OFF
loopback cable RTS ON
to the OUT and CTS ON
Input of the SYNC OFF
Adaptor/TDX
OPTO module
If correct, GO TO step 6045
o If the LEDs are not as shown
above
Replace the Adaptor/TDX
OPTO module (refer to
sec.4.4)
Repeat step 6040
o If the intensity of the OPTO
wire is out of range then it
indicates an error in the OPTO
cable between the OUT port
of the VDU/MSP OPTO module
and the IN port of the Adaptor/TDX
OPTO module.
It is necessary to replace
it or cut a piece of the OPTO
wire and then make a new connector.
When the error is cleared
Verify the Peripheral Subsystem
GO TO step 6900
o If the intensity of the Adaptor/TDX
OPTO module is out of range
then
Replace Adaptor/TDX OPTO
module
(refer to sec. 4.4)
Repeat step 6040
When the error is cleared
Verify the Peripheral
Subsystewm
GO TO step 6900
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6045 Connect the OPTO o The
LEDs
should
be
as
follows:
cables correctly
to the Adaptor/TDX RCVL OFF
OPTO module SYNC OFF
Dismount the two
OPTO wires from If correct, GO TO step 6055
the VDU/MSP OPTO
module.
Connect the Loopback
cable to the OUT
and In port of the
VDU/MSP OPTO
module.
Check the LEDs in
the VDU/MSP OPTO
module.
When the LEDs are
checked disconnect
the Loopback cable
and connect the
OPTO cable proper-
ly to the OPTO
module.
o If the LEDs are not as shown
above
Replace the VDU/MSP OPTO
module
Repeat step 6045
When the error is cleared
Verify the Peripheral
Subsystem
GO TO step 6900
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6050 Check that the o If
correct
GO
TO
step
6055
cables are pro-
perly connected
to the peripheral
and to the TDX/Adap-
tor crate.
Check that the power
LEDs in the TDX/Adaptor
crate is correct
(refer to sec.4.5)
Check that there
is power applied
to the peripheral
Check that the
keylock is ON
o If the L/L Adaptor POWER LED
is OFF then
Check that the power LEDs
are ON in the other modules
in the TDX/
/Adaptor crate
If the power LEDs are OFF in
the other modules, Check the
crate.
If Adaptor crate GO TO
step 5800
If TDX crate GO TO step
4800
If there is power ON in the
other modules then
Replace the L/L Adaptor
Repeat step 6050
If the error still appears
then check the TDX/Adaptor
crate
GO TO step 5800
o If there is no power applied
to the peripheral then correct
it or replace the failing item.
When the error is cleared
Verify the peripheral
subsystem
GO TO step 6900
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6055 Analyze the situa-
tion o If the peripheral is the Maint.Pos.VDU
GO TO step 3400
o If the peripheral is the Maint.Pos.MSP
GO TO step 3500
o If the peripheral is a VDU
(not the Maint.Pos.VDU)
GO TO step 6100
o If the peripheral is a MSP
(not the Maint.Pos.MSP)
GO TO step 6200
o If the peripheral is a PTP/R
GO TO step 6300
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6100 Test Procedures for ENTRY
VDU Delta Data 7260TC
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6115 Check that o If no errors are detected
a) all boards, GO TO Step 6110
connecters are
firmly seated
b) the OPTO module
strapsettings
is correct
(refer to sec. 4.5)
c) all cabling is intact
and no broken or
damaged wires
d) there is no presence
of foreign material
which could course
an electrical short
o If any errors are detected,
correct them or replace the
module(s) and then verify the
VDU.
GO TO Step 6900.
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6110 Run the Built-In-Test o When the power is switched
"ON", then
in the VDU: the bell shall sound immediately
and
a diagnostic confidence test
is run.
Power "OFF" the VDU. After 5-10 seconds, the following
Wait for 5 seconds. output should appear:
Power "ON" the VDU.
"TTY RESET"
If correct, then
GO TO Step 6115.
o If any errors are detected
by the Built-In-Test, then
troubleshoot the VDU (refer
to CPS/TCM/007) and then
Verify the VDU
GO TO Step 6900
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6115 This step contains o This column only lists the
exptected
the test procedure output from the DIAG test.
If any error
of the VDU using in the VDU is detected, then
the VDU
the Internal should be replaced by a spare
unit or
Diagnostic in the troubleshooted as described
in
VDU CPS/TCM/019
Depress "MON" key The Monitor menu appears on
the screen.
Move the cursor
to "DIAG"
Depress "ENTER" ENTER PASSWORD: .......
appears on the screen.
Key in DIAG The diagnostic menu appears
on the screen.
RAM = 7FFF
TESTS:
PF2 = DISPLAY
PF2 = MEMORY
PF3 = I/O
D̲i̲s̲p̲l̲a̲y̲ ̲T̲e̲s̲t̲:̲
Depress "PF1" All possible 24 characters
will be displayed. Check that
the following 7 display attibutes
appear:
1 Characters with strike
through
2 Blank characters
3 Reduced brightness
4 Inverted video
5 Characters with dotted
underline
6 Blinking characters
7 All modes without blank
character
Let the test run for app. 20
sec.
Depress any key The diagnostic menu reappears
on the screen.
R̲A̲M̲ ̲T̲e̲s̲t̲:̲ Elapsed time of RAM test: app.
11 min
Depress "PF2" During the RAM test, the display
is filled with alternating
patterns. When the RAM test
is completed, check that "RAM
OK" is displayed.
E̲A̲R̲O̲M̲ ̲T̲e̲s̲t̲:̲ Elapsed time of EAROM test:
app.10 sec.
Depress any key During the EAROM test, the
two lower lines on the display
will be used and check that
the test is completed with
"EAROM OK".
Depress any key The diagnostic menu appears
on the screen.
I̲/̲O̲-̲P̲o̲r̲t̲ ̲T̲e̲s̲t̲:
Depress "PF3" The screen will display:
"DISCONNECT I/O CABLES"
Disconnect the
cables from I/O Ports.
Depress any key Check that the screen displays:
OK: I/O PORT 01
OK: I/O PORT 02
Depress "ESC" Exit from the diagnostics tests.
"TTY RESET" reappears on the
screen.
The Internal o If no errors are detected,
then
Diagnostic test is
finished. GO TO Step 6120
Depress "RESET"
o If any errors are detected
then troubleshoot the VDU (refer
to CPS/TCM/007) and then
Verify the VDU
GO TO step 6900
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6120 The following steps o In the steps 6130 - 6165,
this column
contain a test of the only contains the expected
output from
VDU using a the test.
Tektronix If any error in the VDU is
detected,
Communication Tester then the VDU should be replaced
by a spare unit or troubleshooted.
(ref to Doc.No. CPS/TCM/007)
T̲E̲S̲T̲ ̲S̲E̲T̲U̲P̲
Set the configuration
of the VDU in test:
CHARSIZE: 7
PARITY: ODD
STOPBITS: 1
BAUD RATE: 9600
Switch the Com. Tester
"OFF" before inserting
the ROM pack RO-1.
Connect the Com. Tester
to the VDU through
PORT 1 (refer to
Figure 4.3.3.6-1).
Switch the power on the
Com. Tester "ON" and
wait for the display
text:
"DELTA TEST READY" Elapsed time of Com.Tester
Setup:
app 15 sec
Depress the start Programming of the configuration
and
button on the Com. setting up of the 16 splits
are
Tester carried out by the Com. Tester.
Elapsed time of split Setup:
app 25 sec.
COM.TESTER - VDU SETUP
Figure 4.3.3.6-1
When the 16 splits are stable
on the screen, observe if any
irregularity, curved lines,
or unlinearity exist. If necessary,
control it with a ruler. Irregularity
and curved lines greater then
5% which are observable by
the naked eye are unacceptable.
GO TO Step 6125
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6135 T̲e̲s̲t̲ ̲o̲f̲ ̲S̲p̲l̲i̲t̲s̲:̲
Write a single
but different
character in each
split. Use the "PRV
SPLIT NXT" to move
the cursor to the
next split. Observe
that each split
can be recalled by
using "PRV SPLIT NXT".
Depress "ENTER" key Check that only one split is
available
or VDU. and that it is possible to
write in it.
GO TO Step 6130
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6130 P̲F̲-̲K̲e̲y̲ ̲T̲e̲s̲t̲:
Depress "ENTER" All 36 PF-Keys are depressed
in
key on VDU succession and it is controlled
that OK is written on the screen
for each PF-Key.
GO TO Step 6135
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6135 F̲i̲e̲l̲d̲ ̲S̲e̲t̲ ̲U̲p̲: Elapsed time of Field Setup:
app 10 sec.
Depress "ENTER" A field set up in format mode
appears on the screen.
Observe that it is only possible
to write in the reserved fields
and only with the right type
of characters as written on
the screen.
Test all fields on both page
1 and page 2. To reach page
2, use "TAB".
Depress "ENTER" The same test as above but
with predetermined characters
as indicated in relevant paranthesis
is carried out. When finished,
GO TO Step 6150
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6140 K̲e̲y̲ ̲F̲i̲l̲t̲e̲r̲ ̲T̲e̲s̲t̲: Elapsed time of key Filter
Setup:
app. 10 sec.
Depress "ENTER" Observe that the keyboard is
on the VDU disabled.
The security key
is turned anti-
clockwise.
Turn the security Observe that the keyboard is
enabled.
key clockwise
Depress "ENTER" After a few seconds, "KBD LOCK"
should
on the VDU reappear on the screen. Observe
that the keyboard is disabled
for about 8 seconds.
GO TO Step 6145
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6145 S̲I̲G̲N̲ ̲O̲N̲ ̲T̲e̲s̲t̲:̲ Elapsed time of SION setup:
app 10 sec.
The SIGN ON command field appears
on the screen.
Key in "SION" in Verify that the command is
accepted
the SIGN ON fields by the program and the BAUD
RATE test
and press "ENTER" starts
on the VDU
GO TO step 6150
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6150 B̲A̲U̲D̲ ̲R̲A̲T̲E̲ ̲T̲e̲s̲t̲: Elapsed time of BAUD RATE test:
app.80 sec.
All baud rates as shown in
the configuration are now automatically
tested with both + and -2.5%.
The test is completed with
the display text "BAUD RATE
TEST OK" on the Com. Tester.
GO TO Step 6155
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6155 The test procedure o If no errors were detected
in Step
of the VDU is now 6100 - 6155, then there is
no error in
finished the VDU.
In case the VDU is connected
to the CAMPS Central Equipment,
then the error must be in there,
therefore:
If the VDU is connected to
the CU Subsystem
GO TO Step 2000
If the VDU is connected to
the TDX Subsystem,
GO TO Step 4000
o If any errors were detected
in Step 6100 - 6155, then troubleshoot
the VDU and then
Verify the VDU
GO TO Step 6900
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6200 Test Procedures for ENTRY
MSP TRACOR Model 8000
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6205 Check that o If no errors are detected,
a) all boards and GO TO Step 6210
connectors are
firmly seated
b) the OPTO module
strapsettings
is correct
(refer sec. 4.5)
c) all cabling is
intact and no
broken or damaged
wires
d) there is no presence
of foreign material
which could cause an
electrical short.
e) the ribbon is
properly installed
and the unit is
loaded with paper
f) the control LEDs +̲ 21V
on Board A1 are ON
g) the control LEDs for
DS1, DS2, DS3 on
Board A10 are ON
o If any errors are detected,
correct them or replace the
module(s) and then verify the
MSP.
GO TO Step 6900
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6210 Check LINE FEED o If no errors are detected,
function:
GO TO Step 6215
Depress the LINE
FEED push botton
for at least one
second.
Verify that one
line feed of paper
occurs followed
by continuous line
feed for as long
as the LINE FEED
is depressed
o If an error is detected, troubleshoot
the MSP (refer to CPS/OPM/009).
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6215 Run the Built-In- o If no errors are detected,
Test:
GO TO Step 6220
Depress the TEST
button until
the bell sounds.
(app. 5 sec)
Verify that the
following is
printed:
"NO ERRORS IN ROM"
"NO ERRORS IN RAM"
66 lines barberpole
test pattern
"END OF SELF TEST"
o If an error is detected, troubleshoot
the MSP (refer to CPS/OPM/009)
and then
Verify the MSP
GO TO Step 6900
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6220 The following steps o In the steps 6230 - 6260,
this column
contain a test of the only contains the expected
output from
MSP using a the test.
Tektronix
Communication
Tester 834
T̲E̲S̲T̲ ̲S̲E̲T̲ ̲U̲P̲:̲ If any error in the MSP is
detected,
then the MSP should be replaced
by a
Switch power "OFF" spare unit or troubleshooted
as
on the MSP. described in the CPS/OPM/009
sec. 4.3.
MSP Baud Rate: 2400
MSP A2 board:
S̲I̲-̲4̲ ̲S̲I̲-̲3̲ ̲S̲I̲-̲2̲ ̲S̲I̲-̲1̲
̲O̲N̲ ̲ ̲ ̲O̲F̲F̲ ̲ ̲O̲N̲ ̲ ̲ ̲O̲F̲F̲ Errors detected by the Com.
Tester
are output as follows:
Parity: NONE Stopbit: 1
MSP A10 board: "HALT XX"
S̲I̲-̲1̲
̲ ̲1̲ ̲ where XX is explained in Step
6265.
S̲2̲-̲6̲ ̲S̲2̲-̲5̲ ̲S̲2̲-̲4̲ ̲S̲2̲-̲3̲
̲0̲ ̲ ̲ ̲ ̲1̲ ̲ ̲ ̲ ̲ ̲1̲ ̲ ̲ ̲ ̲0̲ ̲ GO TO Step 6225
1 = switch open
NORM, LF Sgl, 80 char/l
MSP A7 board:
S̲1̲-̲1̲ ̲S̲1̲-̲2̲ ̲S̲1̲-̲3̲
O̲F̲F̲ ̲ ̲ ̲O̲N̲ ̲ ̲ ̲O̲F̲F̲
Switch the Com. Tester
"OFF" before inserting
the ROM pack RO-2.
Connect the Com. Tester
to the MSP through
Port 1 (refer to
Figure 4.3.3.6-2)
COM.TESTER - MSP SETUP
Figure 4.3.3.6-2
Switch the power on
the MSP "ON" again.
Switch the Com.
Tester "ON" and
wait for the display Elapsed time of Com. Tester
text: Set Up: App. 10 sec.
"TRACOR TEST"
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
* *
* NOTE *
* *
* Below are listed the tests of the MSP which are
incorpo- *
* rated in the Com.Tester - MSP test procedure and
the *
* steps describing them.
*
*
*
* S̲t̲e̲p̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲T̲e̲s̲t̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲*
*
*
* 6225 Paper Out Indicator
*
* 6230 Paper In Motion Switch
*
6235 Parity Check
*
* 6240 Suspend Print and Receive Buffer
*
* 6245 Keylock Function
*
* 6250 Vertical Tabulation Control
Format *
* 6255 Baud Rate
*
* ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲*
*
*
* In each of the following steps are stated: *
* *
* (̲S̲T̲A̲R̲T̲:̲ ̲"̲X̲X̲X̲ ̲T̲R̲A̲N̲S̲F̲E̲R̲"̲ *
* *
* This means that it is possible to select and start
that *
* specific test by entering: "STOP" and then "XXX
TRANSFER") *
* If these commands are not entered, then the Com.
Tester *
* test procedure will automatically proceed to the
next step.*
* *
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
Choose the actual test step depending of the nature
of the error indication.
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6225 T̲e̲s̲t̲ ̲o̲f̲ ̲P̲a̲p̲e̲r̲ ̲O̲u̲t̲ ̲I̲n̲d̲i̲c̲a̲t̲o̲r̲:̲
("102 TRANSFER")
Depress "START" on
Com.Tester Command Message is printed.
Reload only 1 page of Verify that Out of Paper Lamp
on the
paper MSP is lighting and no error
code is
displayed.
Depress "START" on
Com. Tester
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6230 T̲e̲s̲t̲ ̲o̲f̲ ̲P̲a̲p̲e̲r̲ ̲i̲n̲ ̲M̲o̲t̲i̲o̲n̲ ̲S̲w̲i̲t̲c̲h̲
("104 TRANSFER")
Depress "START" on
Com.Tester Command Message is printed.
Make a Paper Jam Verify that Paper Jam is detected
and
on the first page nothing is printed before new
paper
of paper. is reloaded.
Depress "START" on
Com. Tester.
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6235 P̲a̲r̲i̲t̲y̲ ̲C̲h̲e̲c̲k̲ ̲T̲e̲s̲t̲:
("106 TRANSFER")
Depress "START" on
Com.Tester Command Message is printed.
- Select Even parity
on MSP A-10 board:
̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲S̲2̲-̲4̲ ̲S̲2̲-̲3̲
E̲v̲e̲n̲ ̲p̲a̲r̲i̲t̲y̲:̲ ̲ ̲1̲ ̲ ̲ ̲ ̲ ̲1̲ ̲
- Depress "START" on Verify that the parity lamp
on the MSP
Com. Tester. is lighting
- Select ODD parity
on MSP A-10 board:
̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲S̲2̲-̲4̲ ̲S̲2̲-̲3̲
O̲D̲D̲ ̲p̲a̲r̲i̲t̲y̲:̲ ̲ ̲ ̲0̲ ̲ ̲ ̲ ̲ ̲1̲ ̲
- Depress "START" on Verify that the parity lamp
on the MSP
Com. Tester. is lighting
- Select NONE parity
on MSP A-10 board:
̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲S̲2̲-̲4̲ ̲S̲2̲-̲3̲
N̲O̲N̲E̲ ̲p̲a̲r̲i̲t̲y̲:̲ ̲ ̲ ̲0̲ ̲ ̲ ̲ ̲0̲ ̲
- Depress "START" on Verify that the parity shall
not be
Com. Tester. lighting
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6240 Test SUSP. PRINT
and RECEIVE BUFFER:
("108 TRANSFER")
Depress "START" on
Com.Tester Command Message is printed.
Depress "START" on Verify that printing is started
Com. Tester
Before two lines are Verify that printing is stopped
after
printed, depress few seconds. DTR on Com. Tester
is
"SUSP PRINT" switch going "OFF"
on the MSP
Depress "SUSP PRINT" Verify that the DTR is going
"ON" and
switch on the MSP printing is resumed (50 lines
shall be
again printed correctly).
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6245 T̲e̲s̲t̲ ̲K̲E̲Y̲ ̲L̲O̲C̲K̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲:
("110 TRANSFER")
Depress "START" on Command Message is printed
Com. Tester
Depress "START" on
Com. Tester
Turn the Security Verify that nothing is printed
and
key to "OFF" no error code is displayed
on Com.
position. Wait 5 Tester.
sec.
Turn the Security
key to "ON" again.
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6250 Test VERTICAL TABULATION
C̲O̲N̲T̲R̲O̲L̲ ̲F̲O̲R̲M̲A̲T̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
("111 TRANSFER")
Depress "START on
Com.Tester Commenced Message is printed.
Depress "START on Verify that no error codes
are
on Com. Tester displayed on the Com. Tester.
Depress "START" again Verify that the printed format
is correct. (31 lines)
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6255 T̲e̲s̲t̲ ̲B̲A̲U̲D̲ ̲R̲A̲T̲E̲
("115 TRANSFER")
Select Baud Rate = 1200
on MSP
CPU CCA (A2) board:
S̲1̲-̲4̲ ̲S̲1̲-̲3̲ ̲S̲1̲-̲2̲ ̲S̲1̲-̲1̲
̲O̲N̲ ̲ ̲ ̲O̲F̲F̲ ̲ ̲O̲F̲F̲ ̲ ̲O̲N̲ ̲
Depress "START" on 1200 Baud Rate is now tested
with
Com. Tester -2.5%.
Verify that the printed text
is correct. (20 lines)
Depress "START" on 1200 Baud Rate is now tested
with
Com.Tester + 2.5%.
Verify that the printed text
is
correct (20 lines)
GO TO step 6260
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6260 The test procedure o If no errors were detected
in step
of the MSP is now 6200 - 6270, then there is
no error in
finished the MSP.
Set the MSP in the In case the MSP is connected
to the
original configu- CAMPS Central Equipment, then
the
ration (refer to error must be in there.
sec. 4.5)
If the MSP is connected to
the CU Subsystem,
GO TO Step 2000
If the MSP is connected to
the TDX Subsystem,
GO TO Step 4000
o If any errors were detected
in step 6200 - 6270, then troubleshoot
the MSP (refer to TCM/OPM/009
and then
Verify the MSP
GO TO Step 6900
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6265 Error Codes:
This step lists the
MSP error codes from
the Com. Tester
HALT 10 Paper Out Status Signal
HALT 11 Paper On Status Signal
HALT 15 Keylock Status Signal
HALT 16 Keylock Status Signal (On Request)
HALT 17 Unlock Status Signal
HALT 22 Illegal Vertical Tab. Formatting
HALT 23 Illegal Data in Vertical Tab.
Format
HALT 24 Less than five tab. in Vertical
Tab Format
HALT 25 Illegal Host Operational Command
Format
HALT 26 Illegal Data in Host Operational
Command Format
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6300 Test Procedure for ENTRY
EECO/Burroughs, PTP/PTR
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6305 Open the front door o If no errors are detected
of the PTP/R.
Pull the pipe stub GO TO Step 6310
on the micro switch
(PTP/R lower right
side) slightly out-
wards (power on the
EECO drive)
Check that the
a) power switch (EECO
front panel) is "ON"
and power LED is "ON"
b) tape status LED (EECO
front panel) is "OFF"
c) the keylock is "ON"
(front door)
d) the V28 cable is
connected properly
e) there is no error
indication on the
PTP/R
o If any errors are detected,
correct them or troubleshoot
the PTP/R as described in the
PTP/R manual (refer to CPS/TCM/025).
When the error is corrected,
verify the PTP/R.
GO TO Step 6900
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6310 Check that o If no errors are detected,
a) all boards and GO TO Step 6315
connectors
are firmly seated
b) the strapsettings
are correct
(refer to sec. 4.5)
c) all cabling is
intact and that
there are no
broken or damaged
wires
d) there is no presense
of foreign material
which could cause
an electrical short
f) the unit is
loaded with tape
o If any errors are detected,
correct them or troubleshoot
the PTP/R (refer to Doc. No.
CPS/TCM/025) and then verify
the PTP/R.
GO TO Step 6900
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6315 Check the LOAD o If no errors are detected,
function:
Activate the LDR GO TO Step 6320
switch (EECO front
panel) up/down
and verify that
PTP/R produces a
tape leader with
sprocket holes
o If an error is detected, troubleshoot
the PTP/R (refer to Doc. No.
CPS/TCM/025) and then verify
the PTP/R.
GO TO Step 6900
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6320 The following steps o When the Com.Tester is
setup and
contain a test of programmed.
Tektronix Communi-
cation Tester 834 GO TO step 6325
T̲E̲S̲T̲ ̲S̲E̲T̲U̲P̲
Switch power "OFF"
on the PTP/R
Connect the PTP/R
to the Com. Tester
via the test cable
shown in Figure
6.3.3.6-3.
The Com. Tester
setup and program-
ming is shown in
figure 4.3.3.6-4.
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
Testcable…01…Com. Tester - PRP/R
COM. TESTER - PTP/R SETUP
Figure 6.3.3.6-3
C̲o̲m̲.̲ ̲T̲e̲s̲t̲e̲r̲ ̲S̲E̲T̲U̲P̲:̲ OBS: ent = ENTER key on
Com.Tester
trf = TRANSFER
key on Com.Tester
Press: SETUP Display:
- : to move to ASCII…0f…HX…0e… -
:
CODE
= ASCII…0f…HX…0e…
- : - :
- : to move to 600 -
:
BAUD
= 600
- : - : DUPLEX =
FULL
- : - : DELAY = 200
- : - :
- : to move to ASYNC -
:
SETUP
=
ASYNC
- : - : BIT/CHAR
= 8
- : - :
- : to move to EVEN -
:
PARITY
=
EVEN
- : - : STOPBITS
= 1
- : - :
- : [D ent - :
EOF =
[D
C̲o̲m̲.̲ ̲T̲e̲s̲t̲e̲r̲ ̲P̲r̲o̲g̲r̲a̲m̲m̲i̲n̲g̲
Press: PROGRAM key Display:
- : CLEAR key - :
- : - :
- : until SEND appears - :
- : 1 ent - : 1
SEND:
1
- : - :
- : until SEND appears - :
- : 2 ent - : 2
SEND:
2
- : - :
- : until RECEIVE appears - :
3
RECEIVE
- : - :
- : until COMPARE appears - :
- : 2 ent - : 4
COMPARE:
2
- : - :
- : until JUMP EQ appears - :
- : 7 ent - : 5
JUMP
EQ
7
- : - :
- : 3 ent - : 6
HALT:
3
- : - :
- : 4 ent - : 7
HALT:
4
Figure 6.3.3.6-4.a
Com. Tester - PTP/R Programming…86…1…02… …02… …02… …02… …02… …02… …02… …02… …02… …02… …02…
…02… …02…
C̲o̲m̲.̲ ̲T̲e̲s̲t̲e̲r̲ ̲P̲r̲o̲g̲r̲a̲m̲m̲i̲n̲g̲
Press: PROGRAM Display:
- : - :
- : CLEAR -
:
- : - :
- : [ ent [ ent
[ ent [ ent -
: 1M:
[[[[
- : - :
- : [[ trf - :
2M: THE
QUICK
BROWN
- : - :
- : 43 ent 40 ent
5[ ent 2[ ent -
:
3M:
CMP
̲ERR
- : 45 ent 52 ent
52 ent
- : - :
- : 43 ent 40 ent
50 ent 20 ent -
:
- : 4F ent 4B ent -
:
4M:
CMP
̲OK
Figure 6.3.3.6-4.b
Com. Tester - PTP/R Programming …86…1 …02… …02… …02… …02… …02… …02…
…02…
6325 a) Switch power on o The
following
output
should
appear
on
the PTP/R "ON" the Com. Tester:
again.
CMP OK
b) The RUN/LOAD
switch (EECO If correct, then the
PTP/R can punch
front panel) is and read without any
errors.
set to LOAD.
In case the PTP/R is
connected to the
c) Depress the CAMPS equipment, then
the error must
"START" button be in there.
on the Com.
Tester. GO TO step 4000.
d) Check that the
PTP/R is
punching.
e) Activate the LDR
switch (EECO front
panel) up/down
until all punched
tape is visible.
f) Tear off the
punched tape and
feed it into the
reader.
g) The RUN/LOAD switch
is set to run.
Check that the
punched tape runs
through the reader.
o If the PTP/R will either
not punch or read, or
the output on the Com.
Tester is as follows:
CMP ERR
then there is an error
in the PTP/R. Troubleshoot
the PTP/R (refer to
Doc. No. CPS/TCM/025)
and then verify the
PRP/R.
GO TO STEP 6900
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6900 Verify the Peripheral ENTRY
Equipment
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
6905 It is necessary to verify
that the original error
indication is deleted
before the troubleshooting
procedure is finished,
therefore
1) GO TO the original ENTRY
POINT in the Off-line Troubleshooting
Tree (defined by the System
Trouble- shooting Tree).
2) Verify that it is possible
to execute the described
step-by-step procedures
without detecting any errors.
3) If no errors are detected,
the troubleshooting of the
peripheral is finished.
4) Complete failure report
and logbook (refer to section
6).