CAMPS SITE LEVEL MAINTENANCE MANUAL
…02…Issue 1…02… CAMPS

PERIPHERAL TEST PROCEDURES STEP 6000 - 7000 (cont'd)

STEP     PROCEDURE                     OBSERVATION/ACTION
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲






    3864A/ktd  …02…CPS/TCM/005

…02…KJA/830912…02……02… 
CAMPS SITE LEVEL MAINTENANCE MANUAL
…02…Issue 1…02… CAMPS
 























4.3.3.6         P̲E̲R̲I̲P̲H̲E̲R̲A̲L̲ ̲E̲q̲u̲i̲p̲m̲e̲n̲t̲ ̲T̲e̲s̲t̲ ̲P̲r̲o̲c̲e̲d̲u̲r̲e̲s̲





    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

6000                      PERIPHERAL TEST                             ENTRY


    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

6005                      Analyze the situa-                       o If
                                                                     the
                                                                     peripheral
                                                                     is
                                                                     connected
                                                                     via
                                                                     an
    tion                    OPTO module then

                                 GO TO step 6010

                          o If the peripheral is connected
                            via a L/L Adaptor then

                                 GO TO step 6050

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *




6010                      Check that the MSP/                      o The
                                                                     output
                                                                     of
                                                                     the
                                                                     OPTO
                                                                     module/wire
    VDU keylock is ON       should range within

    Check the intensity     - 8dbm to - 34,6 dbm.
    of the OUT port of 
    the VDU/MSP OPTO
    module                  The OPTO LEDs should be as
                            follows:

    Check the intensity
    of the OPTO wire con-           L̲E̲D̲ ̲ ̲ ̲ ̲ ̲V̲D̲U̲ ̲ ̲ ̲ ̲ ̲M̲S̲P̲
    nected to the IN port
    of the VDU/MSP OPTO             POWER   ON      ON
    module.                         RCVL    OFF     OFF
                                    RTS     OFF     ON
    Check that the two              CTS     OFF     ON
    OPTO wires are pro-             SYNC    OFF     OFF
    perly connected to               ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
                                    ̲
    the VDU/MSP.

    Check the LEDs in the
    VDU/MSP OPTO module     If correct, GO TO step 6035


                          o If the POWER LED is OFF then

                            -    Check the OPTO module
                                 fuse (if VDU OPTO)
                            -    Check that power is applied
                                 to the VDU/MSP unit.
                            -    Replace the OPTO module
                                 (if necessary)

                                    Repeat step 6010

                          o If the output intensity of
                            the OPTO module is outside
                            the range then it indicates
                            an error in the VDU/MSP OPTO
                            module.

                                 Replace OPTO module
                                 Repeat step 6010

                          o If the output intensity of
                            the OPTO wire is outside the
                            range

                                 GO TO step 6025

                          o If the LEDs in the VDU/MSP
                            OPTO module are as follows:

                                 RCVL ON or/and
                                 SYNC ON

                            then it indicates an error
                            in the input to the VDU/MSP

                                 GO TO step 6015

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


6015                      Connect a Loopback o           The
                                                         LEDs
                                                         should
                                                         be
                                                         as
                                                         follows:
    cable to the OUT
    and IN port of the           RCVL OFF
    VDU/MSP OPTO module          SYNC OFF

                          If correct, GO TO step 6025

                          o If the LEDs are not as shown
                            above

                                 Replace the VDU/MSP OPTO
                                 module
                                 Repeat step 6015

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *
6020                      Connect the OPTO   o           The
                                                         intensity
                                                         should
                                                         be
                                                         within
                                                         the
    cables properly         range
    to the
    VDU/MSP OPTO module          - 8dbm to - 34,6 dbm

                          If correct GO TO step 6025
    Dismount the two
    OPTO wires from
    the OPTO module in
    the Adaptor/TDX crate

    Check the intensity
    of the OPTO cable con-
    nected to the IN Port
    of the Adaptor/TDX crate.

                          o If the intensity is out of
                            range then it indicates an
                            error in the OPTO cable connected
                            from the OUT port of the VDU/MSP
                            OPTO module and to the IN port
                            of Adaptor/TDX crate.

                            It is necessary to replace
                            it or cut a piece of the OPTO
                            wire and then make a new connector
                            when the error is cleared.

                            Verify the Peripheral Subsystem

                                 GO TO step 6900

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


6025                      Check the intensity            o   The
                                                             intensity
                                                             should
                                                             range
                                                             within:
    of the OUT port
    of the Adaptor/TDX           - 8dbm to - 34,6 dbm
    OPTO module                    
                          If correct, GO TO step 6030

                          o If the intensity is out of
                            range, then it indicates an
                            error in the Adaptor/TDX OPTO
                            module.

                                 Replace the OPTO module
                                 (Refer to sec. 4.4)
                                 Repeat step 6030.

                            When the error is cleared

                                 Verify the Peripheral
                                 Subsystem.

                                    GO TO step 6900

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


6030                      Connect the OPTO   o           -The
                                                         intensity
                                                         should
                                                         be
                                                         within
                                                         the
    Loopback tube to        range:
    the two dismounted
    OPTO wires in the            - 8 dbm to - 34,6 dbm
    Adaptor/TDX crate.      The LEDs should be as follows

    Dismount the OPTO            RCVL OFF
    wire connected to            SYNC OFF
    the IN port of the
    VDU/MSP OPTO module     If correct, then it indicates
                            an error in the Adaptor/TDX
    Check the intensi-      OPTO module
    ty of the dis-        
    mounted OPTO                 Replace the OPTO module
    wire.                        (refer to sec. 4.4)
                                 Verify the Peripheral
                                 Subsystem
    Connect the OPTO
    wire to the IN port          GO TO step 6900
    again.

    Check the LEDs of     o If the intensity is outside
                            the range 
    the VDU/MSP OPTO        then it indicates an error
                            in the OPTO 
    module.                 cable between the OUT port
                            of the Adaptor/TDX OPTO module
                            and the IN port of the VDU/MSP
                            OPTO module.

                            It is necessary to replace
                            it or cut a piece of the OPTO
                            wire and then make a new connector.

                            When the error is cleared

                            Verify the Peripheral Subsystem

                                 GO TO step 6900

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


6035                      Open the doors to the          o   The
                                                             LEDs
                                                             in
                                                             the
                                                             OPTO
                                                             module
                                                             should
                                                             be:
    actual TDX/Adaptor           
    Crate. Check the             POWER ON
    LEDs in the                  RCVL OFF
    TDX/Adaptor OPTO             SYNC OFF
    module connected
    to the VDU/MSP.
                            If correct then it indicates
                            that there is no LED error
                            in the OPTO transmission between
                            the VDU/MSP and the Adaptor/TDX
                            crate.

                                 GO TO step 6055.

                          o If the POWER LED is "OFF" then

                                 Replace OPTO module
                                 (refer to section 4.4)
                                 Repeat step 6035

                            If the POWER LED is still "OFF"
                            then it indicates an error
                            in either the Adaptor/TDX crate
                            or in the Adaptor power supply.

                            If TDX crate: GO TO step 4800
                            If Adaptor crate: GO TO step
                            5800.



                          o If the LEDs in the TDX/Adaptor
                            OPTO module are as follows:

                                 RCVL ON and/or
                                 SYNC ON

                            then it indicates an error
                            in the connection between the
                            TDX/Adaptor OPTO MODULE and
                            the VDU/MSP.

                                 GO TO step 6040.

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *
6040                      Check the intensity            o   The
                                                             output
                                                             should
                                                             be
                                                             within
                                                             the
                                                             range
    from the OUT-port
    of the Adaptor/TDX
    OPTO module                  -8 dbm to -34,6 dbm

    Check the intensity     The LEDs in the Adaptor/TDX
                            OPTO 
    of the OPTO wire        module should be
    connected to the
    IN port.

    Connect the OPTO             RCVL OFF
    loopback cable               RTS ON
    to the OUT and               CTS ON
    Input of the                 SYNC OFF
    Adaptor/TDX
    OPTO module           
                            If correct, GO TO step 6045

                          o If the LEDs are not as shown
                            above

                                 Replace the Adaptor/TDX
                                 OPTO module (refer to
                                 sec.4.4)
                                 Repeat step 6040

                          o If the intensity of the OPTO
                            wire is out of range then it
                            indicates an error in the OPTO
                            cable between the OUT port
                            of the VDU/MSP OPTO module
                            and the IN port of the Adaptor/TDX
                            OPTO module.


                            It is necessary to replace
                            it or cut a piece of the OPTO
                            wire and then make a new connector.

                            When the error is cleared
                            Verify the Peripheral Subsystem

                                 GO TO step 6900

                          o If the intensity of the Adaptor/TDX
                            OPTO module is out of range
                            then

                                 Replace Adaptor/TDX OPTO
                                 module
                                 (refer to sec. 4.4)
                                 Repeat step 6040

                            When the error is cleared

                                 Verify the Peripheral
                                 Subsystewm

                                 GO TO step 6900

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


6045                      Connect the OPTO   o           The
                                                         LEDs
                                                         should
                                                         be
                                                         as
                                                         follows:
    cables correctly
    to the Adaptor/TDX           RCVL OFF
    OPTO module                  SYNC OFF

    Dismount the two
    OPTO wires from         If correct, GO TO step 6055
    the VDU/MSP OPTO
    module.

    Connect the Loopback
    cable to the OUT 
    and In port of the
    VDU/MSP OPTO
    module.

    Check the LEDs in
    the VDU/MSP OPTO
    module.
    When the LEDs are
    checked disconnect
    the Loopback cable
    and connect the
    OPTO cable proper-
    ly to the OPTO
    module.

                          o If the LEDs are not as shown
                            above

                                 Replace the VDU/MSP OPTO
                                 module
                                 Repeat step 6045

                            When the error is cleared

                                 Verify the Peripheral
                                 Subsystem

                                 GO TO step 6900

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


6050                      Check that the                           o If
                                                                     correct
                                                                     GO
                                                                     TO
                                                                     step
                                                                     6055
    cables are pro-
    perly connected
    to the peripheral 
    and to the TDX/Adap-
    tor crate.

    Check that the power 
    LEDs in the TDX/Adaptor
    crate is correct
    (refer to sec.4.5)

    Check that there
    is power applied
    to the peripheral

    Check that the
    keylock is ON

                          o If the L/L Adaptor POWER LED
                            is OFF then

                                 Check that the power LEDs
                                 are ON in the other modules
                                 in the TDX/ 
                                 /Adaptor crate 

                            If the power LEDs are OFF in
                            the other modules, Check the
                            crate.

                                 If Adaptor crate GO TO
                                 step 5800
                                 If TDX crate GO TO step
                                 4800

                            If there is power ON in the
                            other modules then 

                                 Replace the L/L Adaptor
                                 Repeat step 6050

                            If the error still appears
                            then check the TDX/Adaptor
                            crate

                                 GO TO step 5800

                          o If there is no power applied
                            to the peripheral then correct
                            it or replace the failing item.
                            When the error is cleared

                                 Verify the peripheral
                                 subsystem
                                 GO TO step 6900

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


6055                      Analyze the situa-
    tion                  o If the peripheral is the Maint.Pos.VDU

                                 GO TO step 3400

                          o If the peripheral is the Maint.Pos.MSP

                                 GO TO step 3500

                          o If the peripheral is a VDU
                            (not the Maint.Pos.VDU)

                                 GO TO step 6100

                          o If the peripheral is a MSP
                            (not the Maint.Pos.MSP)

                                 GO TO step 6200

                          o If the peripheral is a PTP/R

                                 GO TO step 6300

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

6100                      Test Procedures for                         ENTRY
    VDU Delta Data 7260TC

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *



6115   Check that         o If no errors are detected

    a) all boards,               GO TO Step 6110
       connecters are
       firmly seated

    b) the OPTO module 
       strapsettings
       is correct 
       (refer to sec. 4.5)

    c) all cabling is intact
       and no broken or 
       damaged wires

    d) there is no presence
       of foreign material
       which could course
       an electrical short



                          o If any errors are detected,
                            correct them or replace the
                            module(s) and then verify the
                            VDU.

                                 GO TO Step 6900.

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


6110   Run the Built-In-Test     o  When the power is switched
                                    "ON", then
    in the VDU:             the bell shall sound immediately
                            and
                            a diagnostic confidence test
                            is run.
    Power "OFF" the VDU.    After 5-10 seconds, the following
    Wait for 5 seconds.     output should appear:
    Power "ON" the VDU.   
                                 "TTY RESET"

                            If correct, then

                                 GO TO Step 6115.



                          o If any errors are detected
                            by the Built-In-Test, then
                            troubleshoot the VDU (refer
                            to CPS/TCM/007) and then 

                                 Verify the VDU
                                 GO TO Step 6900

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *



6115   This step contains o This column only lists the
                            exptected 
    the test procedure      output from the DIAG test.
                            If any error
    of the VDU using        in the VDU is detected, then
                            the VDU
    the Internal            should be replaced by a spare
                            unit or
    Diagnostic in the       troubleshooted as described
                            in
    VDU                     CPS/TCM/019

    Depress "MON" key       The Monitor menu appears on
                            the screen.

    Move the cursor 
    to "DIAG"

    Depress "ENTER"         ENTER PASSWORD: .......
                            appears on the screen.

    Key in DIAG             The diagnostic menu appears
                            on the screen.

                            RAM = 7FFF
                            TESTS:
                            PF2 = DISPLAY
                            PF2 = MEMORY
                            PF3 = I/O 


    D̲i̲s̲p̲l̲a̲y̲ ̲T̲e̲s̲t̲:̲

    Depress "PF1"           All possible 24 characters
                            will be displayed. Check that
                            the following 7 display attibutes
                            appear:

                            1    Characters with strike
                                 through

                            2    Blank characters

                            3    Reduced brightness

                            4    Inverted video

                            5    Characters with dotted
                                 underline

                            6    Blinking characters

                            7    All modes without blank
                                 character

                            Let the test run for app. 20
                            sec.     

    Depress any key         The diagnostic menu reappears
                            on the screen.

    R̲A̲M̲ ̲T̲e̲s̲t̲:̲               Elapsed time of RAM test: app.
                            11 min

    Depress "PF2"           During the RAM test, the display
                            is filled with alternating
                            patterns. When the RAM test
                            is completed, check that "RAM
                            OK" is displayed.

    E̲A̲R̲O̲M̲ ̲T̲e̲s̲t̲:̲             Elapsed time of EAROM test:
                            app.10 sec.

    Depress any key         During the EAROM test, the
                            two lower lines on the display
                            will be used and check that
                            the test is completed with
                            "EAROM OK". 

    Depress any key         The diagnostic menu appears
                            on the screen.



    I̲/̲O̲-̲P̲o̲r̲t̲ ̲T̲e̲s̲t̲:

    Depress "PF3"           The screen will display:

                          "DISCONNECT I/O CABLES"

    Disconnect the 
    cables from I/O Ports.

    Depress any key         Check that the screen displays:

                                 OK: I/O PORT 01

                                 OK: I/O PORT 02

    Depress "ESC"           Exit from the diagnostics tests.
                            "TTY RESET" reappears on the
                            screen.

    The Internal          o If no errors are detected,
                            then
    Diagnostic test is
    finished.                    GO TO Step 6120
    Depress "RESET"
                          o If any errors are detected
                            then troubleshoot the VDU (refer
                            to CPS/TCM/007) and then

                                 Verify the VDU
                                 GO TO step 6900

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *





6120   The following steps  o    In the steps 6130 - 6165,
                                 this column
    contain a test of the   only contains the expected
                            output from
    VDU using a             the test.
    Tektronix               If any error in the VDU is
                            detected,
    Communication Tester    then the VDU should be replaced
                            by a spare unit or troubleshooted.
                            (ref to Doc.No. CPS/TCM/007)

    T̲E̲S̲T̲ ̲S̲E̲T̲U̲P̲

    Set the configuration 
    of the VDU in test:

    CHARSIZE: 7
    PARITY: ODD
    STOPBITS: 1
    BAUD RATE: 9600

    Switch the Com. Tester
    "OFF" before inserting
    the ROM pack RO-1.
    Connect the Com. Tester
    to the VDU through     
    PORT 1 (refer to 
    Figure 4.3.3.6-1).

    Switch the power on the 
    Com. Tester "ON" and 
    wait for the display
    text:

    "DELTA TEST READY"      Elapsed time of Com.Tester
                            Setup:
                            app 15 sec

    Depress the start       Programming of the configuration
                            and 
    button on the Com.      setting up of the 16 splits
                            are
    Tester                  carried out by the Com. Tester.

                            Elapsed time of split Setup:
                            app 25 sec.


















































               COM.TESTER - VDU SETUP
                  Figure 4.3.3.6-1


                            When the 16 splits are stable
                            on the screen, observe if any
                            irregularity, curved lines,
                            or unlinearity exist. If necessary,
                            control it with a ruler. Irregularity
                            and curved lines greater then
                            5% which are observable by
                            the naked eye are unacceptable.

                                 GO TO Step 6125

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *



6135   T̲e̲s̲t̲ ̲o̲f̲ ̲S̲p̲l̲i̲t̲s̲:̲

    Write a single
    but different 
    character in each
    split. Use the "PRV
    SPLIT NXT" to move
    the cursor to the
    next split. Observe
    that each split 
    can be recalled by 
    using "PRV SPLIT NXT".
    Depress "ENTER" key     Check that only one split is
                            available
    or VDU.                 and that it is possible to
                            write in it.

                                 GO TO Step 6130

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *



6130   P̲F̲-̲K̲e̲y̲ ̲T̲e̲s̲t̲:

    Depress "ENTER"         All 36 PF-Keys are depressed
                            in
    key on VDU              succession and it is controlled
                            that OK is written on the screen
                            for each PF-Key.

                                 GO TO Step 6135

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *





6135   F̲i̲e̲l̲d̲ ̲S̲e̲t̲ ̲U̲p̲:        Elapsed time of Field Setup:
                            app 10 sec.

    Depress "ENTER"         A field set up in format mode
                            appears on the screen.

                            Observe that it is only possible
                            to write in the reserved fields
                            and only with the right type
                            of characters as written on
                            the screen.

                            Test all fields on both page
                            1 and page 2. To reach page
                            2, use "TAB".

    Depress "ENTER"         The same test as above but
                            with predetermined characters
                            as indicated in relevant paranthesis
                            is carried out. When finished,

                                 GO TO Step 6150

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *



6140   K̲e̲y̲ ̲F̲i̲l̲t̲e̲r̲ ̲T̲e̲s̲t̲:     Elapsed time of key Filter
                            Setup:
                            app. 10 sec.
    Depress "ENTER"         Observe that the keyboard is
                                      
    on the VDU              disabled.                 
                                       

    The security key
    is turned anti-
    clockwise.

    Turn the security       Observe that the keyboard is
                            enabled.
    key clockwise
                                                

    Depress "ENTER"         After a few seconds, "KBD LOCK"
                            should
    on the VDU              reappear on the screen. Observe
                            that the keyboard is disabled
                            for about 8 seconds.

                                 GO TO Step 6145

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *





6145   S̲I̲G̲N̲ ̲O̲N̲ ̲T̲e̲s̲t̲:̲        Elapsed time of SION setup:
                            app 10 sec.

                            The SIGN ON command field appears
                            on the screen.

    Key in "SION" in        Verify that the command is
                            accepted
    the SIGN ON fields      by the program and the BAUD
                            RATE test
    and press "ENTER"       starts
    on the VDU                   
                                 GO TO step 6150

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *



6150   B̲A̲U̲D̲ ̲R̲A̲T̲E̲ ̲T̲e̲s̲t̲:      Elapsed time of BAUD RATE test:
                            app.80 sec.

                            All baud rates as shown in
                            the configuration are now automatically
                            tested with both + and -2.5%.

                            The test is completed with
                            the display text "BAUD RATE
                            TEST OK" on the Com. Tester.

                                 GO TO Step 6155

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *



6155   The test procedure o If no errors were detected
                            in Step 
    of the VDU is now       6100 - 6155, then there is
                            no error in
    finished                the VDU.

                            In case the VDU is connected
                            to the CAMPS Central Equipment,
                            then the error must be in there,
                            therefore:

                            If the VDU is connected to
                            the CU Subsystem

                                 GO TO Step 2000

                            If the VDU is connected to
                            the TDX Subsystem,

                                 GO TO Step 4000





                          o If any errors were detected
                            in Step 6100 - 6155, then troubleshoot
                            the VDU and then 

                                 Verify the VDU
                                 GO TO Step 6900

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *





    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

6200   Test Procedures for                                         ENTRY
    MSP TRACOR Model 8000

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


6205   Check that         o If no errors are detected,

    a) all boards and               GO TO Step 6210
       connectors are
       firmly seated

    b) the OPTO module 
       strapsettings
       is correct 
       (refer sec. 4.5)

    c) all cabling is 
       intact and no 
       broken or damaged
       wires

    d) there is no presence
       of foreign material
       which could cause an
       electrical short.

    e) the ribbon is 
       properly installed
       and the unit is
       loaded with paper

    f) the control LEDs +̲ 21V
       on Board A1 are ON

    g) the control LEDs for
       DS1, DS2, DS3 on
       Board A10 are ON

                          o If any errors are detected,
                            correct them or replace the
                            module(s) and then verify the
                            MSP.

                                    GO TO Step 6900



    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *



6210   Check LINE FEED    o If no errors are detected,
    function:
                                 GO TO Step 6215
    Depress the LINE
    FEED push botton
    for at least one 
    second.
    Verify that one
    line feed of paper
    occurs followed
    by continuous line
    feed for as long
    as the LINE FEED
    is depressed



                          o If an error is detected, troubleshoot
                            the MSP (refer to CPS/OPM/009).

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *



6215   Run the Built-In-  o If no errors are detected,
    Test:
                                 GO TO Step 6220
    Depress the TEST
    button until 
    the bell sounds.
    (app. 5 sec)

    Verify that the
    following is 
    printed:

    "NO ERRORS IN ROM"
    "NO ERRORS IN RAM"
    66 lines barberpole
    test pattern
    "END OF SELF TEST"





                          o If an error is detected, troubleshoot
                            the MSP (refer to CPS/OPM/009)
                            and then

                                 Verify the MSP
                                 GO TO Step 6900

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

6220   The following steps  o In the steps 6230 - 6260,
                              this column
    contain a test of the   only contains the expected
                            output from
    MSP using a             the test.
    Tektronix
    Communication 
    Tester 834

    T̲E̲S̲T̲ ̲S̲E̲T̲ ̲U̲P̲:̲            If any error in the MSP is
                            detected,
                            then the MSP should be replaced
                            by a
    Switch power "OFF"      spare unit or troubleshooted
                            as
    on the MSP.             described in the CPS/OPM/009
                            sec. 4.3.
    MSP Baud Rate: 2400
    MSP A2 board:

    S̲I̲-̲4̲ ̲S̲I̲-̲3̲ ̲S̲I̲-̲2̲ ̲S̲I̲-̲1̲
     ̲O̲N̲ ̲ ̲ ̲O̲F̲F̲ ̲ ̲O̲N̲ ̲ ̲ ̲O̲F̲F̲     Errors detected by the Com.
                            Tester
                            are output as follows:
    Parity: NONE Stopbit: 1
    MSP A10 board:               "HALT XX"

    S̲I̲-̲1̲
     ̲ ̲1̲ ̲                    where XX is explained in Step
                            6265.

    S̲2̲-̲6̲ ̲S̲2̲-̲5̲ ̲S̲2̲-̲4̲ ̲S̲2̲-̲3̲
     ̲0̲ ̲ ̲ ̲ ̲1̲ ̲ ̲ ̲ ̲ ̲1̲ ̲ ̲ ̲ ̲0̲ ̲          GO TO Step 6225
    1 = switch open

    NORM, LF Sgl, 80 char/l
    MSP A7 board:

    S̲1̲-̲1̲ ̲S̲1̲-̲2̲ ̲S̲1̲-̲3̲
    O̲F̲F̲ ̲ ̲ ̲O̲N̲ ̲ ̲ ̲O̲F̲F̲

    Switch the Com. Tester
    "OFF" before inserting
    the ROM pack RO-2.
    Connect the Com. Tester
    to the MSP through 
    Port 1 (refer to
    Figure 4.3.3.6-2)



















































               COM.TESTER - MSP SETUP
                  Figure 4.3.3.6-2


    Switch the power on
    the MSP "ON" again.
    Switch the Com.
    Tester "ON" and
    wait for the display    Elapsed time of Com. Tester
    text:                   Set Up: App. 10 sec.

    "TRACOR TEST"



    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *
    *                                                             *
    *                       NOTE                                  *
    *                                                             *
    *  Below are listed the tests of the MSP which are
       incorpo-           *
    *  rated in the Com.Tester - MSP test procedure and
       the                *
    *  steps describing them.                         
                  *
    *                                                 
               *
    *  S̲t̲e̲p̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲T̲e̲s̲t̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
       ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲*
    *                                                 
               *
    *  6225                Paper Out Indicator        
                  *
    *  6230                Paper In Motion Switch     
                  *
       6235                Parity Check               
                  *
    *  6240                Suspend Print and Receive Buffer
             *
    *  6245                Keylock Function           
                  *
    *  6250                Vertical Tabulation Control
       Format     *
    *  6255                Baud Rate                  
                  *
    *   ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
       ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲*
    *                                                 
               *
    *  In each of the following steps are stated:                 *
    *                                                             *
    *  (̲S̲T̲A̲R̲T̲:̲ ̲"̲X̲X̲X̲ ̲T̲R̲A̲N̲S̲F̲E̲R̲"̲                                     *
    *                                                             *
    *  This means that it is possible to select and start
       that               *
    *  specific test by entering: "STOP" and then "XXX
       TRANSFER")         *
    *  If these commands are not entered, then the Com.
       Tester             *
    *  test procedure will automatically proceed to the
       next step.*
    *                                                             *
    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


    Choose the actual test step depending of the nature
    of the error indication.


    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

6225   T̲e̲s̲t̲ ̲o̲f̲ ̲P̲a̲p̲e̲r̲ ̲O̲u̲t̲ ̲I̲n̲d̲i̲c̲a̲t̲o̲r̲:̲

    ("102 TRANSFER")
    Depress "START" on
    Com.Tester              Command Message is printed.
    Reload only 1 page of   Verify that Out of Paper Lamp
                            on the
    paper                   MSP is lighting and no error
                            code is
                            displayed.
    Depress "START" on
    Com. Tester                  

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *



6230   T̲e̲s̲t̲ ̲o̲f̲ ̲P̲a̲p̲e̲r̲ ̲i̲n̲ ̲M̲o̲t̲i̲o̲n̲ ̲S̲w̲i̲t̲c̲h̲

    ("104 TRANSFER")
    Depress "START" on
    Com.Tester              Command Message is printed.

    Make a Paper Jam        Verify that Paper Jam is detected
                            and
    on the first page       nothing is printed before new
                            paper
    of paper.               is reloaded.

    Depress "START" on                          
    Com. Tester.

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *





6235   P̲a̲r̲i̲t̲y̲ ̲C̲h̲e̲c̲k̲ ̲T̲e̲s̲t̲:

    ("106 TRANSFER")
    Depress "START" on 
    Com.Tester              Command Message is printed.

    -  Select Even parity 
       on MSP A-10 board: 

        ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲S̲2̲-̲4̲ ̲S̲2̲-̲3̲
       E̲v̲e̲n̲ ̲p̲a̲r̲i̲t̲y̲:̲ ̲ ̲1̲ ̲ ̲ ̲ ̲ ̲1̲ ̲

    -  Depress "START" on   Verify that the parity lamp
                            on the MSP
       Com. Tester.         is lighting

    -  Select ODD parity 
       on MSP A-10 board:

        ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲S̲2̲-̲4̲ ̲S̲2̲-̲3̲
       O̲D̲D̲ ̲p̲a̲r̲i̲t̲y̲:̲ ̲ ̲ ̲0̲ ̲ ̲ ̲ ̲ ̲1̲ ̲

    -  Depress "START" on   Verify that the parity lamp
                            on the MSP
       Com. Tester.         is lighting

    -  Select NONE parity  
       on MSP A-10 board:

        ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲S̲2̲-̲4̲ ̲S̲2̲-̲3̲
       N̲O̲N̲E̲ ̲p̲a̲r̲i̲t̲y̲:̲ ̲ ̲ ̲0̲ ̲ ̲ ̲ ̲0̲ ̲

    -  Depress "START" on   Verify that the parity shall
                            not be
       Com. Tester.         lighting

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *





6240   Test SUSP. PRINT
    and RECEIVE BUFFER:
    ("108 TRANSFER")
    Depress "START" on
    Com.Tester              Command Message is printed.

    Depress "START" on      Verify that printing is started
    Com. Tester

    Before two lines are    Verify that printing is stopped
                            after
    printed, depress        few seconds. DTR on Com. Tester
                            is
    "SUSP PRINT" switch     going "OFF"
    on the MSP

    Depress "SUSP PRINT"    Verify that the DTR is going
                            "ON" and
    switch on the MSP       printing is resumed (50 lines
                            shall be
    again                   printed correctly).

                                 

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *



6245   T̲e̲s̲t̲ ̲K̲E̲Y̲ ̲L̲O̲C̲K̲ ̲F̲u̲n̲c̲t̲i̲o̲n̲:

    ("110 TRANSFER")

    Depress "START" on      Command Message is printed
    Com. Tester

    Depress "START" on 
    Com. Tester
    Turn the Security       Verify that nothing is printed
                            and 
    key to "OFF"            no error code is displayed
                            on Com.
    position. Wait 5        Tester.
    sec.
    Turn the Security
    key to "ON" again.              

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *





6250   Test VERTICAL TABULATION
    C̲O̲N̲T̲R̲O̲L̲ ̲F̲O̲R̲M̲A̲T̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

    ("111 TRANSFER")
    Depress "START on
    Com.Tester              Commenced Message is printed.
    Depress "START on       Verify that no error codes
                            are
    on Com. Tester          displayed on the Com. Tester.

    Depress "START" again   Verify that the printed format
                            is correct. (31 lines)

                                 

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *



6255   T̲e̲s̲t̲ ̲B̲A̲U̲D̲ ̲R̲A̲T̲E̲

    ("115 TRANSFER")

    Select Baud Rate = 1200
    on MSP
    CPU CCA (A2) board:

    S̲1̲-̲4̲ ̲S̲1̲-̲3̲ ̲S̲1̲-̲2̲ ̲S̲1̲-̲1̲
     ̲O̲N̲ ̲ ̲ ̲O̲F̲F̲ ̲ ̲O̲F̲F̲ ̲ ̲O̲N̲ ̲

    Depress "START" on      1200 Baud Rate is now tested
                            with  
    Com. Tester             -2.5%.

                            Verify that the printed text
                            is correct. (20 lines)

                                 

    Depress "START" on      1200 Baud Rate is now tested
                            with
    Com.Tester              + 2.5%.

                            Verify that the printed text
                            is
                            correct (20 lines)

                                 GO TO step 6260

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


6260   The test procedure   o    If no errors were detected
                                 in step
    of the MSP is now       6200 - 6270, then there is
                            no error in
    finished                the MSP.

    Set the MSP in the      In case the MSP is connected
                            to the
    original configu-       CAMPS Central Equipment, then
                            the
    ration (refer to        error must be in there.
    sec. 4.5)
                            If the MSP is connected to
                            the CU Subsystem,

                                 GO TO Step 2000

                            If the MSP is connected to
                            the TDX Subsystem,

                                 GO TO Step 4000

                          o If any errors were detected
                            in step 6200 - 6270, then troubleshoot
                            the MSP (refer to TCM/OPM/009
                            and then

                                 Verify the MSP
                                 GO TO Step 6900

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *



6265   Error Codes:

    This step lists the
    MSP error codes from
    the Com. Tester

    HALT 10               Paper Out Status Signal
    HALT 11               Paper On Status Signal
    HALT 15               Keylock Status Signal
    HALT 16               Keylock Status Signal (On Request)
    HALT 17               Unlock Status Signal
    HALT 22               Illegal Vertical Tab. Formatting
    HALT 23               Illegal Data in Vertical Tab.
                          Format
    HALT 24               Less than five tab. in Vertical
                          Tab Format
    HALT 25               Illegal Host Operational Command
                          Format
    HALT 26               Illegal Data in Host Operational
                          Command Format

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

6300   Test Procedure for           ENTRY
    EECO/Burroughs, PTP/PTR

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *



6305   Open the front door  o    If no errors are detected
    of the PTP/R.
    Pull the pipe stub           GO TO Step 6310
    on the micro switch
    (PTP/R lower right
    side) slightly out-
    wards (power on the
    EECO drive)

    Check that the

    a) power switch (EECO
       front panel) is "ON"
       and power LED is "ON"

    b) tape status LED (EECO
       front panel) is "OFF"

    c) the keylock is "ON"
       (front door)
    d) the V28 cable is
       connected properly

    e) there is no error
       indication on the
       PTP/R



                          o If any errors are detected,
                            correct them or troubleshoot
                            the PTP/R as described in the
                            PTP/R manual (refer to CPS/TCM/025).
                            When the error is corrected,
                            verify the PTP/R.

                                 GO TO Step 6900

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *





6310   Check that         o If no errors are detected,

    a) all boards and            GO TO Step 6315
       connectors
       are firmly seated

    b) the strapsettings
       are correct
       (refer to sec. 4.5)

    c) all cabling is
       intact and that
       there are no
       broken or damaged
       wires

    d) there is no presense
       of foreign material
       which could cause
       an electrical short

    f) the unit is
       loaded with tape



                          o If any errors are detected,
                            correct them or troubleshoot
                            the PTP/R (refer to Doc. No.
                            CPS/TCM/025) and then verify
                            the PTP/R.

                                 GO TO Step 6900

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *





6315   Check the LOAD     o If no errors are detected,
    function:
    Activate the LDR             GO TO Step 6320
    switch (EECO front
    panel) up/down
    and verify that
    PTP/R produces a
    tape leader with
    sprocket holes



                          o If an error is detected, troubleshoot
                            the PTP/R (refer to Doc. No.
                            CPS/TCM/025) and then verify
                            the PTP/R.

                                 GO TO Step 6900

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *





6320   The following steps  o    When the Com.Tester is
                                 setup and
    contain a test of       programmed.
    Tektronix Communi-
    cation Tester 834            GO TO step 6325

    T̲E̲S̲T̲ ̲S̲E̲T̲U̲P̲

    Switch power "OFF"
    on the PTP/R

    Connect the PTP/R
    to the Com. Tester
    via the test cable
    shown in Figure
    6.3.3.6-3.

    The Com. Tester 
    setup and program-
    ming is shown in 
    figure 4.3.3.6-4.

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *




















            Testcable…01…Com. Tester - PRP/R































              COM. TESTER - PTP/R SETUP
                  Figure 6.3.3.6-3



    C̲o̲m̲.̲ ̲T̲e̲s̲t̲e̲r̲ ̲S̲E̲T̲U̲P̲:̲      OBS: ent = ENTER key on
                            Com.Tester
                                    trf = TRANSFER
                               key on Com.Tester

    Press: SETUP                 Display:
    -    :                  to move to ASCII…0f…HX…0e…  - 
                                                  
                                                 :
                                                CODE
                                                = ASCII…0f…HX…0e…
    -    :                       -      :
    -    :                  to move to 600      - 
                                                  
                                                 :
                                                BAUD
                                                = 600
    -    :                       -      : DUPLEX =
                                 FULL
    -    :                       -      : DELAY = 200
    -    :                       -      :
    -    :                  to move to ASYNC          -
                                                      
                                                      
                                                      
                                                      
                                                      
                                                      :
                                                      SETUP
                                                      =
                                                      ASYNC
    -    :                           -      : BIT/CHAR
                                     = 8
    -    :                       -      :
    -    :                  to move to EVEN           -  
                                                         
                                                         
                                                         :
                                                         PARITY
                                                         =
                                                         EVEN
    -    :                       -      : STOPBITS
                                     = 1
    -    :                       -      :
    -    : [D               ent            -     :
                                              EOF =
                                              [D

    C̲o̲m̲.̲ ̲T̲e̲s̲t̲e̲r̲ ̲P̲r̲o̲g̲r̲a̲m̲m̲i̲n̲g̲

    Press: PROGRAM key           Display:
    -       :               CLEAR key         -       :
    -       :                        -     :
    -       :               until SEND appears        -           :
    -       :               1 ent          -    : 1
                                                SEND:
                                                1
    -       :                        -     :
    -       :               until SEND appears        -           :
    -       :               2 ent          -    : 2
                                                SEND:
                                                2
    -       :                        -     :
    -       :               until RECEIVE appears     -           :
                                                                  3
                                                                  RECEIVE
    -       :                        -     :
    -       :               until COMPARE appears     -           :
    -       :               2 ent          -    : 4
                                                COMPARE:
                                                2
    -       :                        -     :
    -       :               until JUMP EQ appears     -           :
    -       :               7 ent          -    : 5
                                                JUMP
                                                EQ
                                                7
    -       :                        -     :  
    -       :               3 ent          -    : 6
                                                HALT:
                                                3
    -       :                        -     :      
                                              
    -       :               4 ent          -    : 7
                                                HALT:
                                                4




               Figure 6.3.3.6-4.a
Com. Tester - PTP/R Programming…86…1…02…   …02…      …02…                …02…  …02… …02…   …02…     …02…  …02… …02…     …02…
  …02…        …02…
    C̲o̲m̲.̲ ̲T̲e̲s̲t̲e̲r̲ ̲P̲r̲o̲g̲r̲a̲m̲m̲i̲n̲g̲

    Press: PROGRAM               Display:
    -       :                              -     :
    -       :               CLEAR             -   
                                                :
    -       :                        -     :
    -       :               [ ent [ ent
                            [ ent [ ent       -   
                                                : 1M:
                                                [[[[
    -       :                        -     :
    -       :               [[ trf         -     :
                                              2M: THE
                                              QUICK
                                              BROWN
    -       :                        -     :
    -       :               43 ent 40 ent
                            5[ ent 2[ ent       -     
                                                      
                                                      
                                                      :
                                                      3M:
                                                      CMP
                                                      ̲ERR
    -       :               45 ent 52 ent
                            52 ent
    -       :                        -     :
    -       :               43 ent 40 ent
                            50 ent 20 ent       -     
                                                      
                                                      
                                                      :
                                                      
                                                      
                                                      
                                                      
                                                      
                                                      
                                                      
                                                      
                                                      
                                                      
                                                      
    -       :               4F ent 4B ent       -     
                                                      
                                                      
                                                      :
                                                      4M:
                                                      CMP
                                                      ̲OK



























               Figure 6.3.3.6-4.b
Com. Tester - PTP/R Programming …86…1    …02…  …02…                  …02… …02…    …02…  …02…            
                 …02…
6325       a)               Switch power on   o The
                                                following
                                                output
                                                should
                                                appear
                                                on
           the PTP/R "ON"      the Com. Tester:
           again.
                                     CMP OK
    b)     The RUN/LOAD
           switch (EECO        If correct, then the
                               PTP/R can punch
           front panel) is     and read without any
                               errors.
           set to LOAD.
                               In case the PTP/R is
                               connected to the
    c)     Depress the         CAMPS equipment, then
                               the error must
           "START" button      be in there.
           on the Com.
           Tester.               GO TO step 4000.

    d)     Check that the 
           PTP/R is
           punching.

    e)     Activate the LDR
           switch (EECO front
           panel) up/down
           until all punched
           tape is visible.

    f)     Tear off the
           punched tape and 
           feed it into the
           reader.

    g)     The RUN/LOAD switch
           is set to run.
           Check that the 
           punched tape runs
           through the reader.



                            o  If the PTP/R will either
                               not punch or read, or
                               the output on the Com.
                               Tester is as follows:

                                 CMP ERR

                               then there is an error
                               in the PTP/R. Troubleshoot
                               the PTP/R (refer to
                               Doc. No. CPS/TCM/025)
                               and then verify the
                               PRP/R.

                                 GO TO STEP 6900


    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

6900   Verify the Peripheral                                      ENTRY
    Equipment

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *



6905                             It is necessary to verify
                                 that the original error
                                 indication is deleted
                                 before the troubleshooting
                                 procedure is finished,
                                 therefore 

                            1) GO TO the original ENTRY
                               POINT in the Off-line Troubleshooting
                               Tree (defined by the System
                               Trouble- shooting Tree).

                            2) Verify that it is possible
                               to execute the described
                               step-by-step procedures
                               without detecting any errors.

                            3) If no errors are detected,
                               the troubleshooting of the
                               peripheral is finished.

                            4) Complete failure report
                               and logbook (refer to section
                               6).